Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installers. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. LIMITED WARRANTY Unless otherwise noted, Sloan Valve Company warrants its Products to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for SF Fau- cets, special finishes and PWT electronics and 30 days on PWT software) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER. AD-81000 Deck Sink Lavatory System Corian/Quartz (Pages 2-3) AD-82000 Deck Sink Lavatory System Corian/Quartz (Pages 4-5) AD-83000 Deck Sink Lavatory System Corian/Quartz (Pages 6-7) AD-84000 Deck Sink Lavatory System Corian/Quartz (Pages 8-9) AER-DEC™-81000/82000/83000/84000 Integrated Sink System Single/Double/Triple/Quadruple Station Corian® or Quartz Lavatory Systems IMPORTANT Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical power MUST remain off until installation is complete. Installer’s hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out rating of 1,000 lbs. For standard height mounting, do not exceed the recommended 34” distance from the top of the lav deck to the finished floor. To meet ADA requirements, the lav deck cannot exceed the 34” maximum height dimension. 1 Installation Instruction Code No. 0816672 Rev.2 (07/15) PRIOR TO INSTALLATION Important: • Adequate structural support in or behind the wall is required. Refer to the appropriate rough-in diagram for dry weight of sink. Refer to pages 10 and 11 for sink and stud support requirements. All plumbing should be installed in accordance with applicable codes and regulations. • Before connecting flex hoses to supply stops, flush all water lines until water is clear. • Hot and cold water supply lines/tempered supply line and drain lines. • 3/8” x 2 1/2” lag screws, wall anchors, bolts (minimum pull-out rating of 1000 Ibs./450 kg). See Frame Mounting Support drawing for required lag screws for your specific lavatory system. • 1/2” NPT hot/cold or tempered supply piping • 1 1/2” NPT drain piping including p-trap • Adhesive: Loctite ® PL Premium ® FAST GRAB Polyurethane Construction Adhesive • 110 volt GFCI protected electrical outlet for 100-120 VAC plug-in trans- former • Screen filter(s) included with faucet(s) • Backing supplied by others to meet local codes SUPPLIES REQUIRED FOR INSTALLATION OF SINKS Wear all proper safety equipment prior to installation.

Upload: saraaraya

Post on 02-Dec-2015

2 views

Category:

Documents


0 download

DESCRIPTION

0816672(1)

TRANSCRIPT

Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installers.

Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts.

Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction.

LIMITED WARRANTYUnless otherwise noted, Sloan Valve Company warrants its Products to be made of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for SF Fau-cets, special finishes and PWT electronics and 30 days on PWT software) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

AD-81000 Deck Sink Lavatory System

Corian/Quartz (Pages 2-3)

AD-82000 Deck Sink Lavatory System

Corian/Quartz (Pages 4-5)

AD-83000 Deck Sink Lavatory System

Corian/Quartz (Pages 6-7)

AD-84000 Deck Sink Lavatory System

Corian/Quartz (Pages 8-9)

AER-DEC™-81000/82000/83000/84000 Integrated Sink System Single/Double/Triple/Quadruple Station Corian® or Quartz Lavatory Systems

IMPORTANT

Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical power MUST remain off until installation is complete.

Installer’s hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out rating of 1,000 lbs.

For standard height mounting, do not exceed the recommended 34” distance from the top of the lav deck to the finished floor. To meet ADA requirements, the lav deck cannot exceed the 34” maximum height dimension.

1

InstallationInstructionCode No. 0816672Rev.2 (07/15)

PRIOR TO INSTALLATIONImportant:• Adequate structural support in or behind the wall is required. Refer to the

appropriate rough-in diagram for dry weight of sink. Refer to pages 10 and 11 for sink and stud support requirements.

• All plumbing should be installed in accordance with applicable codes and regulations.

• Before connecting flex hoses to supply stops, flush all water lines until water is clear.

• Hot and cold water supply lines/tempered supply line and drain lines.

• 3/8” x 2 1/2” lag screws, wall anchors, bolts (minimum pull-out rating of 1000 Ibs./450 kg). See Frame Mounting Support drawing for required lag screws for your specific lavatory system.

• 1/2” NPT hot/cold or tempered supply piping• 1 1/2” NPT drain piping including p-trap

• Adhesive: Loctite® PL Premium® FAST GRAB Polyurethane Construction Adhesive

• 110 volt GFCI protected electrical outlet for 100-120 VAC plug-in trans-former

• Screen filter(s) included with faucet(s)• Backing supplied by others to meet local codes

SUPPLIES REQUIRED FOR INSTALLATION OF SINKS

Wear all proper safety equipment prior to installation.

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW SINGLE STATION

2

Backing material (required)(not supplied)

20”Water Supplies

19” drain

14”to bottomof DryerMounting Plate

12” tobottom of frame

Hand DryerMotor

NOTE:1. Backing materialshould equal thicknessof drywall (1/2” min.)

23” A.F.F.

21”frame

Sloan Foam Soap Dispenser

1/2” Backing material

Muf�er (patent applied for)

Trough 1” deep at start of trough3/4” width at bottom of trough2” Hand Dryer Motor Hose (overall 56 3/4”)Electrical outlet boxes (not supplied)Standard 3” x 5” duplex GFI receptaclesHand dryers - 120V/20AmpFaucets/Soap - 120V/15Amp

Drywall

1/2” Solid surface

1/2” Backing Material1/4” x 4” Steel plateVented basin design(patent applied for)

Drain box & clean out (patent applied for)

Optional aluminum C-Channel w/LEDs inside tract (120 volt transformer required)

34”

5”

7 1/4”

27”

8” min.

16 1/8”Accesspanel

5 1/2”3/4”

11 1/8”

17” min.

11”

9”

6” Max.

6” max.

Drywall

3”1/2”

1”

Air dam (patent applied for)

23 1/2”23”

22” to end of frameSloan BASYS Mid Faucet

Sloan BASYS Hand Dryer Spout(patent applied for)

Finished Floor

Push button latches snapinto place inside tubing

Stainless steelaccess door hangs on rectangular tubing frame

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW SINGLE STATION

Muf�er with 2” Hand Dryer Motor Hose (Overall 56 3/4”) Fasten Frame to 1/8”

thick steel strappingor backing material

22” backingmaterial

1/2” or 5/8”x 30” x 22” backing material(not supplied)securely fasten tostuds

3/4”

30”

2”34”

Hot water supply

21”frame

33” to topof frame

Drainclean-out

Cold water supply

HAND DRYER MOTOR12.5” x 11.4” x 12.4” deep

Finished Floor

6 1/4” x 9 1/4” x 7.63”Soap Reservior

NOTES:1. Mount Hand Dryer Motor Hose and soap dispenser to spec. location2. Slip frame over mounted components and properly fasten frame tobacking material

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW SINGLE STATION

34”

33” to top of frame

19”Drain

Finished FloorCold Water Supply

Hotwater supply

26” Water Supplies 30” Basin ONLY

Fasten frame to 1/8” thick steelstrapping or backing material

(1) Hand dryerGFI Receptacle120V/20AMPStandard 3” x 5”duplex receptaclesper sink manufacturerrequirements

(1) GFI Receptacle for soap& sensor faucets, TransformerPlug 120V/20AMP required by National Electrical Code

30”

23”A.F.F.

Hand dryermotor mounting plate

Soap Reservior

NOTES:1. Hand Dryer Motor alone is only 500 watts or less with speed control2. Hand Dryer Motor with heater requires 1500 watts or less with speed control3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug5. cut backing to allow for electrical and plumbing componentsROUGH-IN PLUMBING & ELECTRICAL

2”4”4”

7 1/2”

Adhesive

FRAME SUPPORT1. Back edge of Deck may require scribing to �nished wall.2. Shim all gaps between frame and deck, especialy under trough area.

MOUNTING FAUCETS, SOAP DISPENSERS & HAND DRYERS / ATTACHING DECK TO FRAME ENCLOSURE SINGLE STATION

3

DRAIN ASSEMBLY AND FRAME ENCLOSURE MOUNTING SUPPORT SINGLE STATION

Wood Stud per schedule

2”x10” wood reinforcement between studs

Backing (supplied by others) to meet local codes

Drywall

33"

Frame Enclosure

Hand Dryer Motor w/ Mufer Attachment

Soap Reservior

GFI 4 gang outlet(not supplied)

Lag Bolts

Access Panel

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW SINGLE STATION

HAND DRYER/SOAP DISPENSERRefer to installation instructions withcomponent.

1. Measure outside of frame. Cut-out drywall window.2. Remove drywall window.3. Replace with backing supplied by others (per local code).4. Using mounting template,

mount hand dryer motor, Soap Dispenser

Pump (optional) and electrical outlets to backing.

1. For ease of installation, leave the deck laying on its back. Install faucets, optional soap dispens-ers and hand dryers according to manufacturers instructions.

2. Hook-up hand dryer motor hose to hand dryer motors. Do not connect power until air spout is completely installed.

3. Install all water connections, drain lines and components.

Sloan BASYS Mid Faucet Spout

Sloan BASYS Hand Dryer

Drain w/clean-outGRID STRAINER TO BE CLEANEDOUT AS REQUIRED

1/2” Solid Surface

Air Dam Vent

Sloan Foam Soap Dispenser

23 1/2”

3/4”

5 3/8”

1/2” 1”

3”

21”30”

4 1/2”4 1/2”1 3/4”

8 1/2”6 1/2”4 1/2” 2”

CONNECT CONTROLCABLE TO HAND DRYERMOTOR

BAYONET TURNTO LOCK HOSE TOHAND DRYER MOTOR

PROGRAMINGCABLE. LEAVEUNATTACHED

HAND DRYER MOTOR

BASYS DRYER SPOUT SUBASSEMBLY

HOSE & MUFFLER HOLDING NUT ASSEMBLY

CONNECT GROUND

BAYONET TURNTO LOCK HOSE

TO SPOUT

WIRE TO HANDDRYER MOTOR

HAND DRYER MOTOR

SOAP DISPENSER MOTOR ASSEMBLY

BASYS SOAP SPOUT SUBASSEMBLY

HOLDING NUT ASSEMBLY

SOAP DISPENSER LINES

POWER ADAPTOR

12” 12”

12” 12”

6” 6”

*Hole Location for Mounting Frame

5. Mount top of frame at 33” above finished floor.

6. Securely fasten with 1,000 Lb pull out lag bolts.7. Attach access panel to frame.

*Due to manufacturing tolerances, all dimensions are for reference only.

EHD-510 ESD-400

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW DOUBLE STATION

4

Fasten frame to1/8” thick steelstrapping or backing (not supplied)

1/2” or 5/8” x 60” x 22” backingsecurely fasten to studs

Finished �oor

Hot water supplyCold water supply

Drain clean-outMuf�er with 2” Hand Dryer Motor Hose (Overall 56 3/4”)

21” frame

Brace11 1/2”Brace

34”

22”Backing

33”to topof frame

Hand Dryer Motor12.5” x 11.4“ x 12.4” deep

6 1/4” x 9 1/4” x 7.63 Soap Reserviors

NOTES:1. Mount hand dryer motor & soap dispenser to spec location2. Slip frame over mounted components & properly fasten frame to backed wall3. Hot & Cold water supply lines location subject to local code

60”

18”18”

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW DOUBLE STATION

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW DOUBLE STATION

NOTES:1. Hand Dryer Motor alone is only 500 watts or less with speed control2. Hand Dryer Motor with heater requires 1500 watts or less with speed control3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug5. cut backing to allow for electrical and plumbing componentsROUGH-IN PLUMBING & ELECTRICAL

(2) Hand dryer motorGFI Receptacle120V/20AMP

Standard 3” x 5”duplex receptaclesper sink manufacturerrequirements

Hand dryermotor mounting plate

Soap Reservior

Soap ReserviorHand dryer

motor mounting plate

33” to top of frame34”

(2) GFI Receptacle for soap& sensor faucets, transformerplug 120V/20AMP required by national electrical code

6”

23”A.F.F.

Finished �oorHotwater supply

20”water supplies

Fasten frame to 1/8” thick steelstrapping or backing material5” 5” 5”2”10 3/4” 9 1/4”

5”Coldwater supply

11 1/2”

60”

Backing material (required)(not supplied)

20”Water Supplies

19” drain

14”to bottomof DryerMounting Plate

12” tobottom of frame

Hand DryerMotor

NOTE:1. Backing materialshould equal thicknessof drywall (1/2” min.)

23” A.F.F.

21”frame

Sloan Foam Soap Dispenser

1/2” Backing material

Muf�er (patent applied for)

Trough 1” deep at start of trough3/4” width at bottom of trough2” Hand Dryer Motor Hose (overall 56 3/4”)Electrical outlet boxes (not supplied)Standard 3” x 5” duplex GFI receptaclesHand dryers - 120V/20AmpFaucets/Soap - 120V/15Amp

Drywall

1/2” Solid surface

1/2” Backing Material1/4” x 4” Steel plateVented basin design(patent applied for)

Drain box & clean out (patent applied for)

Optional aluminum C-Channel w/LEDs inside tract (120 volt transformer required)

34”

5”

7 1/4”

27”

8” min.

16 1/8”Accesspanel

5 1/2”3/4”

11 1/8”

17” min.

11”

9”

6” Max.

6” max.

Drywall

3”1/2”

1”

Air dam (patent applied for)

23 1/2”23”

22” to end of frameSloan BASYS Mid Faucet

Sloan BASYS Hand Dryer Spout(patent applied for)

Finished Floor

Push button latches snapinto place inside tubing

Stainless steelaccess door hangs on rectangular tubing frame

DRAIN ASSEMBLY AND FRAME MOUNTING SUPPORT DOUBLE STATION

MOUNTING FAUCETS / ATTACHING DECK TO FRAME DOUBLE STATION

5

Wood Stud per schedule

2”x10” wood reinforcement between studs

Backing supplied by others to meet local codes

Drywall

33"

GFI 4 gang outlet

Hand Dryer Motorw/ Mufer Attachment Frame Enclosure

Wood ScrewsLag Bolts

Soap Reservior

Access Panel

Sloan BASYSHand Dryer

Sloan BASYSMid FaucetSloan Foamsoap dispensers

Drain w/clean-outGrid strainer to be cleaned out as required

1/2” Solid surface

Air dam/vent

4 1/2” 4 1/2”1 3/4”

23 1/2”

3”

3/4”

5 3/8”

1/2” 1”1”

7 1/2” 6 1/2” 8 1/2” 7 1/2” 6 1/2” 7 1/2”

60”51”

32”

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW DOUBLE STATION

AdhesiveAdhesive

FRAME SUPPORT1. Back edge of Deck may require scribing to �nished wall.2. Shim all gaps between frame and deck, especially under trough area.

1. For ease of installation, leave the deck laying on its back. Install faucets, optional soap dispens-ers and hand dryers according to manufacturers instructions.

2. Hook-up hand dryer motor hose to hand dryer motors. Do not connect power until air spout is completely installed.

3. Install all water connections, drain lines and components.

1. Measure outside of frame. Cut-out drywall window2. Remove drywall window.3. Replace with backing supplied by

others (per local code).

4. Using mounting template, mount hand dryer motor, soap dispenser pump (optional) and electrical outlets to backing.

5. Mount top of frame at 33” above finished floor.

6. Securely fasten with 1,000 Lb pull out lag bolts.7. Attach access panel to frame.

12” 12”

12” 12”

6” 6”

12” 12”

*Hole Location for Mounting Frame

*Due to manufacturing tolerances, all dimensions are for reference only.

HAND DRYER/SOAP DISPENSERRefer to installation instructions withcomponent.

CONNECT CONTROLCABLE TO HAND DRYERMOTOR

BAYONET TURNTO LOCK HOSE TOHAND DRYER MOTOR

PROGRAMINGCABLE. LEAVEUNATTACHED

HAND DRYER MOTOR

BASYS DRYER SPOUT SUBASSEMBLY

HOSE & MUFFLER HOLDING NUT ASSEMBLY

CONNECT GROUND

BAYONET TURNTO LOCK HOSE

TO SPOUT

WIRE TO HANDDRYER MOTOR

HAND DRYER MOTOR

SOAP DISPENSER MOTOR ASSEMBLY

BASYS SOAP SPOUT SUBASSEMBLY

HOLDING NUT ASSEMBLY

SOAP DISPENSER LINES

POWER ADAPTOR

EHD-510 ESD-400

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW TRIPLE STATION

6

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW TRIPLE STATION

NOTES:1. Mount hand dryer motor & soap dispenser to spec location2. Slip frame over mounted components & properly fasten frame to backed wall3. Hot & Cold water supply lines location subject to local code

Finished FloorHot water supply

Cold water supplyHand Dryer Motor12.5” x 11.4“ x 12.4” deep

6 1/4” x 9 1/4” x 7.63 Soap Reserviors

Fasten frame to1/8” thick steelstrapping or backing(not supplied)

1/2” or 5/8” x 60” x 22” backingsecurely fasten to studs

21” frame

33”to topof frame

Drain clean-outs Muf�er with 2” hand dryer motor hose

90”30” 30”

22”Backing

BraceBrace

Soap Reservior

Soap Reservior

Soap Reservior

OPTIONAL Coldwater supply

OPTIONAL Hotwater supply

34”

Backing material (required)(not supplied)

20”Water Supplies

19” drain

14”to bottomof DryerMounting Plate

12” tobottom of frame

Hand DryerMotor

NOTE:1. Backing materialshould equal thicknessof drywall (1/2” min.)

23” A.F.F.

21”frame

Sloan Foam Soap Dispenser

1/2” Backing material

Muf�er (patent applied for)

Trough 1” deep at start of trough3/4” width at bottom of trough2” Hand Dryer Motor Hose (overall 56 3/4”)Electrical outlet boxes (not supplied)Standard 3” x 5” duplex GFI receptaclesHand dryers - 120V/20AmpFaucets/Soap - 120V/15Amp

Drywall

1/2” Solid surface

1/2” Backing Material1/4” x 4” Steel plateVented basin design(patent applied for)

Drain box & clean out (patent applied for)

Optional aluminum C-Channel w/LEDs inside tract (120 volt transformer required)

34”

5”

7 1/4”

27”

8” min.

16 1/8”Accesspanel

5 1/2”3/4”

11 1/8”

17” min.

11”

9”

6” Max.

6” max.

Drywall

3”1/2”

1”

Air dam (patent applied for)

23 1/2”23”

22” to end of frameSloan BASYS Mid Faucet

Sloan BASYS Hand Dryer Spout(patent applied for)

Finished Floor

Push button latches snapinto place inside tubing

Stainless steelaccess door hangs on rectangular tubing frame

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW TRIPLE STATION

NOTES:1.Hand Dryer Motor alone is only 500 watts or less with speed control2. Hand Dryer Motor with heater requires 1500 watts or less with speed control3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug5. cut backing to allow for electrical and plumbing componentsROUGH-IN PLUMBING & ELECTRICAL

Soap Reservior

Hand dryermotor mounting plate

33” to top of frame

34”

(3) GFI Receptacle for soap& sensor faucets, transformerplug 120V/20AMP required by national electrical code

20”water supplies

5”Fasten frame to 1/8” thick steelstrapping or backing material (not supplied)

Standard 3” x 5”duplex receptaclesper sink manufacturerrequirements

(3) Hand dryer motorGFI Receptacle120V/20AMP

2” 4 1/4” 11 1/2”6 5/8”

19”Drains Hot

water supply

Coldwater supply

23”A.F.F.

Finished Floor

OPTIONAL Cold water supply

OPTIONAL Hotwater supply

Hand dryermotor mounting plate

Soap Reservior

Soap Reservior6” 6”

2”

90”

2 7/8”

Hand dryermotor mounting plate

DRAIN ASSEMBLY AND FRAME MOUNTING SUPPORT TRIPLE STATION

33”

Drywall Backing supplied by others to meet local codes

Steel/Wood Stud2”x4” or 2”x6”(See page 10 for steel stud installationrequirements)

2”x10” WoodReinforcementin between studs(See page 10 for steel stud installationrequirements)

Hand Dryer Motorw/ Muf�er Attachment

Frame EnclosureLag Bolts

Soap Reservior

Access Panels (2)

MOUNTING FAUCETS / ATTACHING DECK TO FRAME TRIPLE STATION

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW TRIPLE STATION

Adhesive

FRAME SUPPORT1. Back edge of Deck may require scribing to �nished wall.2. Shim all gaps between frame and deck, especialy under trough area.

81”

Sloan BASYSHand Dryer

Sloan BASYSMid Faucet

Sloan FoamSoap Dispensers

Drain w/clean-outGrid strainer to be cleaned out as required

1/2” Solid surface

Air dam/vent

90” 4 1/2” 4 1/2”

1 3/4”

23 1/2”

3”

3/4”

5 3/8”

31”31”7 1/2” 6 1/2” 8 1/2” 8 1/2” 6 1/2” 7 1/2”

High Point

8 1/2” 6 1/2”

1. For ease of installation, leave the deck laying on its back. Install faucets, optional soap dispens-ers and hand dryers according to manufacturers instructions.

2. Hook-up hand dryer motor hose to hand dryer motors. Do not connect power until air spout is completely installed.

3. Install all water connections, drain lines and components.

1. Measure outside of frame. Cut-out drywall window2. Remove drywall window.3. Replace with backing supplied by

others (per local code).

4. Using mounting template, mount hand dryer motor, soap dispenser pump (optional) and electrical outlets to backing.

5. Mount top of frame at 33” above finished floor.

6. Securely fasten with 1,000 Lb pull out lag bolts.7. Attach access panel to frame.

12” 12”

12” 12”

6” 6”

12” 12”12” 12” 12”

12”

*Hole Location for Mounting Frame

*Due to manufacturing tolerances, all dimensions are for reference only.

7

HAND DRYER/SOAP DISPENSERRefer to installation instructions withcomponent.

CONNECT CONTROLCABLE TO HAND DRYERMOTOR

BAYONET TURNTO LOCK HOSE TOHAND DRYER MOTOR

PROGRAMINGCABLE. LEAVEUNATTACHED

HAND DRYER MOTOR

BASYS DRYER SPOUT SUBASSEMBLY

HOSE & MUFFLER HOLDING NUT ASSEMBLY

CONNECT GROUND

BAYONET TURNTO LOCK HOSE

TO SPOUT

WIRE TO HANDDRYER MOTOR

HAND DRYER MOTOR

SOAP DISPENSER MOTOR ASSEMBLY

BASYS SOAP SPOUT SUBASSEMBLY

HOLDING NUT ASSEMBLY

SOAP DISPENSER LINES

POWER ADAPTOR

EHD-510 ESD-400

LAVATORY SYSTEM ROUGH-IN DIMENSIONS FRONT VIEW QUADRUPLE STATION

LAVATORY SYSTEM ROUGH-IN DIMENSIONS SIDE VIEW QUADRUPLE STATION

8

NOTES:1. Mount hand dryer motor & soap dispenser to spec location2. Slip frame over mounted components & properly fasten frame to backed wall3. Hot & Cold water supply lines location subject to local code

Fasten frame to1/8” thick steelstrapping or backing

1/2” or 5/8” x 60” x 22” backing securely fasten to studs

22”Backing

Finished �oorHot water supply

Cold water supply

Drain clean-outsBrace

Soap Reservior

Soap Reservior

Soap Reservior

Cold water supplyHot water supply

Hand dryer motor12.5” x 11.4“ x 12.4” deep

6 1/4” x 9 1/4” x 7.63 deep soap reserviors

12” tobottom offrame

3 1/2”

21 3/4”16 3/8” 9 1/4” 9 1/4” 20 5/8” 16 3/8”

120”29”

Muf�er with 2” hand dryer motor hose

29”

33”to topof frame

21” frame

34”

Soap Reservior

Brace

LAVATORY SYSTEM ROUGH-IN PLUMBING & ELECTRICAL DIMENSIONS FRONT VIEW QUADRUPLE STATION

Backing material (required)(not supplied)

20”Water Supplies

19” drain

14”to bottomof DryerMounting Plate

12” tobottom of frame

Hand DryerMotor

NOTE:1. Backing materialshould equal thicknessof drywall (1/2” min.)

23” A.F.F.

21”frame

Sloan Foam Soap Dispenser

1/2” Backing material

Muf�er (patent applied for)

Trough 1” deep at start of trough3/4” width at bottom of trough2” Hand Dryer Motor Hose (overall 56 3/4”)Electrical outlet boxes (not supplied)Standard 3” x 5” duplex GFI receptaclesHand dryers - 120V/20AmpFaucets/Soap - 120V/15Amp

Drywall

1/2” Solid surface

1/2” Backing Material1/4” x 4” Steel plateVented basin design(patent applied for)

Drain box & clean out (patent applied for)

Optional aluminum C-Channel w/LEDs inside tract (120 volt transformer required)

34”

5”

7 1/4”

27”

8” min.

16 1/8”Accesspanel

5 1/2”3/4”

11 1/8”

17” min.

11”

9”

6” Max.

6” max.

Drywall

3”1/2”

1”

Air dam (patent applied for)

23 1/2”23”

22” to end of frameSloan BASYS Mid Faucet

Sloan BASYS Hand Dryer Spout(patent applied for)

Finished Floor

Push button latches snapinto place inside tubing

Stainless steelaccess door hangs on rectangular tubing frame

NOTES:1. Hand Dryer Motor alone is only 500 watts or less with speed control2. Hand Dryer Motor with heater requires 1500 watts or less with speed control3. Hand Dryer Motor must be plugged into a dedicated 20 amp GFI safety circuit4. Hand Dryer Motor to have a dedicated circuit with power cord and grounded plug5. cut backing to allow for electrical and plumbing componentsROUGH-IN PLUMBING & ELECTRICAL

(4) GFI Receptacle for soap& sensor faucets, transformerplug 120V/20AMP required by National Electrical Code

(4) Hand dryer GFI Receptacle120V/20AMP

Standard 3” x 5”duplex receptacles per sink manufacturer requirements

20”water supplies

Hotwater supply

Coldwater supply

23”A.F.F.

Hotwater supply

Coldwater supply Finished Floor

Hand dryermotor mounting plate

Hand Dryermotor mounting plate

Hand Dryermotor mounting plate

Hand dryermotor mounting plate

Soap Reservior

Soap Reservior

Soap Reservior

Soap Reservior

2” 2”

14”

6”

11” 8” 2” 10 7/8” 8” 2” 12 3/8”

19”Drains

6”

Fasten frame to 1/8” thick steelstrapping or backing material (not supplied)

33” to top of frame34”

7 7/8”

120”

9

33”

Steel/Wood Stud2”x4” or 2”x6”(See page 10 for steel stud installationrequirements)

Drywall2”x10” WoodReinforcementin between studs(See page 10 for steel stud installationrequirements)

Backing supplied by others to meet local codes

Frame EnclosureLag Bolts

Access Panels (2)

Hand Dryer Motorw/ Muf�er Attachment

Soap Reservior

Drain w/clean-outGrid strainer to be cleaned out as required

Drain w/clean-outGrid strainer to be cleaned out as required

7”31” 31” 7”

23 1/2”

31”

1/2” Solid surface

Air Dam/Vent1/2”

4 1/2” 4 1/2” 111”120”

1 3/4”

3/4”

8 1/2”6 1/2”6 1/2”

Sloan BASYSHand Dryer

Sloan BASYSMid Faucet

Sloan FoamSoap Dispensers

DRAIN ASSEMBLY AND FRAME MOUNTING SUPPORT QUADRUPLE STATION

MOUNTING FAUCETS / ATTACHING DECK TO FRAME QUADRUPLE STATION

LAVATORY SYSTEM ROUGH-IN DIMENSIONS TOP VIEW QUADRUPLE STATION

Adhesive

FRAME SUPPORT1. Back edge of Deck may require scribing to �nished wall.2. Shim all gaps between frame and deck, especialy under trough area.

1. For ease of installation, leave the deck laying on its back. Install faucets, optional soap dispens-ers and hand dryers according to manufacturers instructions.

2. Hook-up hand dryer motor hose to hand dryer motors. Do not connect power until air spout is completely installed.

3. Install all water connections, drain lines and components.

1. Measure outside of frame. Cut-out drywall window2. Remove drywall window.3. Replace with backing supplied by

others (per local code).

4. Using mounting template, mount hand dryer motor, soap dispenser pump (optional) and electrical outlets to backing.

5. Mount top of frame at 33” above finished floor.

6. Securely fasten with 1,000 Lb pull out lag bolts.7. Attach access panel to frame.

12” 12”

12” 12”

6” 6”

12” 12”12” 12” 12”

12”

12”

12” 12”12”

*Hole Location for Mounting Frame

*Due to manufacturing tolerances, all dimensions are for reference only.

HAND DRYER/SOAP DISPENSERRefer to installation instructions withcomponent.

CONNECT CONTROLCABLE TO HAND DRYERMOTOR

BAYONET TURNTO LOCK HOSE TOHAND DRYER MOTOR

PROGRAMINGCABLE. LEAVEUNATTACHED

HAND DRYER MOTOR

BASYS DRYER SPOUT SUBASSEMBLY

HOSE & MUFFLER HOLDING NUT ASSEMBLY

CONNECT GROUND

BAYONET TURNTO LOCK HOSE

TO SPOUT

WIRE TO HANDDRYER MOTOR

HAND DRYER MOTOR

SOAP DISPENSER MOTOR ASSEMBLY

BASYS SOAP SPOUT SUBASSEMBLY

HOLDING NUT ASSEMBLY

SOAP DISPENSER LINES

POWER ADAPTOR

EHD-510 ESD-400

10

Wall/Stud Height Depth Flange Min.

Gauge

10’

3-5/8”

1-3/8” 14

1-5/8” 16

2” 16

2-1/2” 18

6”

1-3/8” 18

1-5/8” 18

2” 18

2-1/2” 18

3” 16

12’

3-5/8”

1-3/8” 14

1-5/8” 16

2” 16

2-1/2” 16

6”

1-3/8” 16

1-5/8” 18

2” 18

2-1/2” 18

3” 16

14’

3-5/8”

1-3/8” 12

1-5/8” 16

2” 16

2-1/2” 16

6”

1-3/8” 16

1-5/8” 18

2” 18

2-1/2” 18

3” 16

16’

3-5/8”

1-3/8” 14

1-5/8” 14

2” 16

2-1/2” 16

6”

1-5/8” 16

2” 18

2-1/2” 18

3” 16

18’

3-5/8”

1-3/8” 12

1-5/8” 12

2” 16

2-1/2” 12

6”

1-5/8” 16

2” 18

2-1/2” 18

3” 16

20’

3-5/8”

1-5/8” 12

2” 14

2-1/2” 16

3” 16

6”

2” 18

2-1/2” 18

3” 16

Wall/ Stud

HeightStud

Studs Req. @16” o.c.

(See Note 1)Species Grade

10’2x4 2

SPF No. 2

2x6 1

12’2x4 3

2x6 1

14’2x4 3

2x6 1

16’2x4 3

2x6 1

18’2x4 3

2x6 1

20’2x4 3

2x6 2Note 1: Where mutiple studs are listed, bunch multiple studs and space multiple studs @16” o.c. across width of sink

Wood Framing for AD Series Corian Sinks

Cold Formed Steel Framing for AD Series Corian Sinks

Corian Sink Design Requirements:Max. sink deck depth = 25”Max. sink dead weight (including stone and fixture = 10 psfMax. concentrated live load at edge of sink = 500lbs.Provide anchor spacing noted within product drawings

SINK BRACKET STUD SUPPORT

Backing supplied by others to meet local codes

COLD FORMED STEEL FRAME MOUNTING SUPPORT

Metal Stud per schedule

5” - 18 gauge stud reinforcement between studs

Sink Length

Sink SystemEnclosure

Drywall

Drywall

2"

35"

42"

Wood Stud per schedule

2”x10” wood reinforcement between studs

Sink Length

Sink SystemEnclosure

Backing supplied by others to meet local codes

WOOD FRAME MOUNTING SUPPORTDrywall

35"

2'42"

Drywall

11

CLEANING AND MAINTENANCE

Material Description: Corian Material is made from a blend of acrylic modified bio-based polyester resin. Engineered Stone is 90% natural quartz and polyester resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives.

Routine Cleaning: For regular cleaning, use standard commercial or household products such as Simple Green®, Creamy Cleanser brand, Formula 409® or Windex® .

Stubborn Stains: Remove tough stains, with non abrasive cleaners and pads such as a white Scotch Brite® pad and Lysol®. Special Situations for Corian and Engineered Stone

Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit thoroughly after cleaning.

Restoring the surface: Refresh and restore the rich surface with one of the following:

Geo Series: Color enhancer such as Tenax® Ager

Pearl Series: Impregnating sealer such as DryTreat Stain - Proof Original™ or Miracle Sealants 511 Impregnator Do not use strong acid or alkaline chemicals and cleansers to clean Engineered Stone. If these chemicals come in contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects.

Repair Kits: Corian repair kits are available. Contact your Sloan Stone Sink Systems representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days. Engineered Stone shades of color can vary from product to product.

BRAND NAMES

Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions.

REGULAR CLEANING OF DRAIN BOX REQUIRED.

Wall/ Stud

HeightStud

Studs Req. @16” o.c.

(See Note 1)Species Grade

10’2x4 3

SPF No. 2

2x6 1

12’2x4 3

2x6 1

14’2x4 3

2x6 1

16’2x4 3

2x6 2

18’2x4 3

2x6 2

20’2x4 3

2x6 2Note 1: Where mutiple studs are listed, bunch multiple studs and space multiple studs @16” o.c. across width of sink

Wood Framing for AD Series Quartz Sinks

Quartz Sink Design Requirements:Max. sink deck depth = 25”Max. sink dead weight (including stone and fixture = 20 psfMax. concentrated live load at edge of sink = 500lbs.Provide anchor spacing noted within product drawings

Wall/Stud Height Depth Flange Min.

Gauge

10’

3-5/8”

1-3/8” 14

1-5/8” 16

2” 16

2-1/2” 18

6”

1-3/8” 18

1-5/8” 18

2” 18

2-1/2” 18

3” 16

12’

3-5/8”

1-3/8” 14

1-5/8” 16

2” 16

2-1/2” 16

6”

1-3/8” 16

1-5/8” 18

2” 18

2-1/2” 18

3” 16

14’

3-5/8”

1-3/8” 12

1-5/8” 16

2” 16

2-1/2” 16

6”

1-3/8” 16

1-5/8” 18

2” 18

2-1/2” 18

3” 16

16’

3-5/8”

1-3/8” 14

1-5/8” 14

2” 16

2-1/2” 16

6”

1-5/8” 16

2” 18

2-1/2” 18

3” 16

18’

3-5/8”

1-3/8” 12

1-5/8” 12

2” 16

2-1/2” 12

6”

1-5/8” 16

2” 18

2-1/2” 18

3” 16

20’

3-5/8”

1-5/8” 12

2” 14

2-1/2” 16

3” 16

6”

2” 18

2-1/2” 18

3” 16

Cold Formed Steel Framing for AD Series Corian Sinks

ACCESS PANEL

DRAIN BOX

FINISHED FLOOR

FINISHED WALL

DRAIN BOX

GRID STRAINER

1. Lift access panel up by pressing button(s) on bottom of frame.

2. Swing outward until panel separates frame.

3. Lift and separate from frame.

4. Clean grid strainer with rag and dispose of properly.

5. Close access panel.

1

2

3

4

Deck

Enclosure

Grid Strainer Assembly DS-57

OptionalNot Provided Chrome or Plastic P-Trap

Rubber GasketSlip WasherFlange Nut

Sloan Optional Water Temperature Mixing Valves

Mix-60-A Mix-135-A

Basys Mid Faucet (EFX Series)

Basys High Faucet (EFX Series)

Basys Low Pedestal Faucet (EFX Series)

Basys Low Integrated Faucet (EFX Series)

Basys Wall Mount Faucet (EFX Series)

Basys Hand Dryer

Basys Soap Dispenser

COMPONENTS QUADRUPLE STATION

Enclosure

DeckGrid Strainer Assembly DS-57

OptionalNot Provided Chrome or Plastic P-Trap

Rubber GasketSlip WasherFlange Nut

Sloan Optional Water Temperature Mixing Valves

Mix-60-A Mix-135-A

Basys Mid Faucet (EFX Series)

Basys High Faucet (EFX Series)

Basys Low Pedestal Faucet (EFX Series)

Basys Low Integrated Faucet (EFX Series)

Basys Wall Mount Faucet (EFX Series)

Basys Hand Dryer

Basys Soap Dispenser

COMPONENTS TRIPLE STATION

COMPONENTS DOUBLE STATION

Deck

Enclosure

Grid Strainer Assembly DS-57

OptionalNot Provided Chrome or Plastic P-Trap

Rubber GasketSlip WasherFlange Nut

Sloan Optional Water Temperature Mixing Valves

Mix-60-A Mix-135-A

Basys Mid Faucet (EFX Series)

Basys High Faucet (EFX Series)

Basys Low Pedestal Faucet (EFX Series)

Basys Low Integrated Faucet (EFX Series)

Basys Wall Mount Faucet (EFX Series)

Basys Hand Dryer

Basys Soap Dispenser

COMPONENTS SINGLE STATION

Deck

Enclosure

Grid Strainer Assembly DS-57

OptionalNot Provided Chrome or Plastic P-Trap

Rubber GasketSlip WasherFlange Nut

Sloan Optional Water Temperature Mixing Valves

Mix-60-A Mix-135-A

Basys Mid Faucet (EFX Series)

Basys High Faucet (EFX Series)

Basys Low Pedestal Faucet (EFX Series)

Basys Low Integrated Faucet (EFX Series)

Basys Wall Mount Faucet (EFX Series)

Basys Hand Dryer

Basys Soap Dispenser

12

Sloan Valve Company10500 Seymour AvenueFranklin Park, IL [email protected] Tel. 800.982.5839

The information contained in this document is subject to change without notice.Copyright © 2015 Sloan Valve Company CODE NO. 0816672– Rev. 2 (07/15)