08/10/21 20:20:03 32zt7702 001 honda eu26i·eu30is owner’s … · 2017-06-05 · manuel de...

72
OWNER’S MANUAL MANUEL DE L’UTILISATEUR BEDIENUNGSANLEITUNG MANUAL DE EXPLICACIONES Honda EU26i·EU30is The‘‘e-SPEC’’mark symbolizes environmentally responsible technologies applied to Honda power equipment, which contains our wish to ‘‘preserve nature for generations to come.’’

Upload: others

Post on 30-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

OWNER’S MANUAL

MANUEL DE L’UTILISATEUR

BEDIENUNGSANLEITUNG

MANUAL DE EXPLICACIONES

Honda EU26i·EU30is

The‘‘e-SPEC’’mark symbolizes environmentallyresponsible technologies applied to Honda powerequipment, which contains our wish to ‘‘preserve naturefor generations to come.’’

08/10/21 20:20:03 32ZT7702_001

08/10/21 20:20:05 32ZT7702_002

1

Indicates a strong possibility of severe personal injury ordeath if instructions are not followed.

Indicates a possibility of personal injury or equipmentdamage if instructions are not followed.

Honda generator is designed to give safe and dependable service ifoperated according to instructions. Read and understand the Owner’sManual before operating the generator. Failure to do so could resultin personal injury or equipment damage.

Thank you for purchasing a Honda generator.

All information in this publication is based on the latest productinformation available at the time of approval for printing.

Honda Motor Co., Ltd. reserves the right to make changes at any timewithout notice and without incurring any obligation.

No part of this publication may be reproduced without writtenpermission.

This manual should be considered a permanent part of the generatorand should remain with it if it is resold.

Pay special attention to statements preceded by the following words:

Gives helpful information.

If a problem should arise, or if you have any questions about thegenerator, consult an authorized Honda dealer.

This manual covers operation and maintenance of the EU26i andEU30is generators.

The illustration may vary according to the type.

08/10/21 20:20:15 32ZT7702_003

2

CONTENTS

..................................................................SAFETY INSTRUCTIONS . 3............................................................SAFETY LABEL LOCATIONS . 7

.................................................CE mark and noise label locations . 11.....................................................COMPONENT IDENTIFICATION . 12

................................................................PRE-OPERATION CHECK . 16.................................................................STARTING THE ENGINE . 21

High altitude operation...........................................................................GENERATOR USE . 28

.................................................................STOPPING THE ENGINE . 40...............................................................................MAINTENANCE . 42

...........................................................TRANSPORTING/STORAGE . 53......................................................................TROUBLESHOOTING . 55

.............................................................................SPECIFICATIONS . 57..........................................................................WIRING DIAGRAM . 61

................................MAJOR Honda DISTRIBUTOR ADDRESSES . 67

1.2.

3.4.5.

6.7.8.9.

10.11.12.13.

08/10/21 20:20:19 32ZT7702_004

3

SAFETY INSTRUCTIONS1.

IMPORTANT SAFETY INFORMATION

Operator Responsibility

Honda generators are designed for use with electrical equipment thathas suitable power requirements. Other uses can result in injury to theoperator or damage to the generator and other property.Most injuries or property damage can be prevented if you follow allinstructions in this manual and on the generator. The most commonhazards are discussed below, along with the best way to protectyourself and others.

Never attempt to modify the generator. It can cause an accident aswell as damage to the generator and appliances.

Do not connect an extension to the muffler.Do not modify the intake system.Do not adjust the governor.Do not remove the control panel or do not change the wiring of thecontrol panel.

Know how to stop the generator quickly in case of emergency.Understand the use of all generator controls, output receptacles, andconnections.Be sure that anyone who operates the generator receives properinstruction. Do not let children operate the generator without parentalsupervision.

Do not operate the generator with any cover removed. You may getyour hand or foot caught in the generator and it may cause accident.

Place the generator on a firm level place before operation.

Consult your authorized Honda dealer for disassembly and service ofthe generator that are not covered in this manual.

Be sure to observe the instructions in this manual for how to use thegenerator and maintenance information. Ignoring or improperlyfollowing the instructions can cause an accident such as an electricshock, and the condition of the exhaust gas may deteriorate.

08/10/21 20:20:28 32ZT7702_005

4

Carbon Monoxide Hazards

Electric Shock Hazards

Exhaust contains poisonous carbon monoxide, a colorless, odorlessgas. Breathing exhaust can cause loss of consciousness and may leadto death.

If you run the generator in an area that is confined, or even partiallyenclosed area, the air you breathe could contain dangerous amount ofexhaust gas.

The generator produces enough electric power to cause a seriousshock or electrocution if misused.Using a generator or electrical appliance in wet conditions, such asrain or snow, or near a pool or sprinkler system, or when your handsare wet, could result in electrocution.Keep the generator dry.

If the generator is stored outdoors, unprotected from the weather,check all of the electrical components on the control panel before eachuse. Moisture or ice can cause a malfunction or short circuit inelectrical components that could result in electrocution.

If you get an electric shock, consult a doctor and have medicaltreatment immediately.

Do not connect to a building’s electrical system unless an isolationswitch has been installed by a qualified electrician.

Never run your generator inside a garage, house, or near openwindows or doors.

08/10/21 20:20:37 32ZT7702_006

--

5

Fire and Burn Hazards

Refuel With Care

Do not use the generator in areas with a high risk of fire.

When installed in ventilated rooms, additional requirements for fireand explosion protection shall be observed.

The exhaust system gets hot enough to ignite some materials.Keep the generator at least 1 meter (3 feet) away from buildings andother equipment during operation.Do not enclose the generator in any structure.Keep flammable materials away from the generator.

Some parts of the internal combustion engine are hot and may causeburns. Pay attention to the warnings on the generator.

The muffler becomes very hot during operation and remains hot for awhile after stopping the engine. Be careful not to touch the mufflerwhile it is hot. Let the engine cool before storing the generator indoors.

Do not pour the water directly on the generator to put out the firewhen it occurs. Use an appropriate fire extinguisher speciallydesigned for electric fire or oil fire.

If you inhale fumes produced by an accidental fire with the generator,consult a doctor and have medical treatment immediately.

Gasoline is extremely flammable, and gasoline vapor can explode.Allow the engine to cool if the generator has been in operation.

Refuel only outdoors in a well ventilated area with the engine OFF.

Do not overfill the fuel tank.

Never smoke near gasoline, and keep other flames and sparks away.

Always store gasoline in an approved container.

Make sure that any spilled fuel has been wiped up before starting theengine.

08/10/21 20:20:46 32ZT7702_007

6

DisposalTo protect the environment, do not dispose of the used generator,battery, engine oil, etc. carelessly by leaving them in the waste.Observe the local laws or regulations or consult your authorizedHonda generator dealer to dispose of these parts.

Please dispose of used motor oil in a manner that is compatible withthe environment. We suggest you take it in a sealed container to yourlocal service station for reclamation. Do not throw it in the trash orpour it on the ground.

An improperly disposed battery can hurt the environment. Alwaysconfirm local regulations for battery disposal. Contact your Hondaservicing dealer for a replacement.

08/10/21 20:20:51 32ZT7702_008

7

SAFETY LABEL LOCATIONS2.

HOT CAUTION

EXHAUST CAUTION

READ OWNER’S MANUAL

SOCKET CAUTION

CONNECTCAUTION

FUEL CAUTION/PARALLEL OPERATION CAUTION

G, GW, B, F types

These labels warn you of potential hazards that can cause seriousinjury. Read the labels and safety notes and precautions described inthis manual carefully.

If a label comes off or becomes hard to read, contact your Hondadealer for a replacement.

08/10/21 20:21:03 32ZT7702_009

8

Honda generator is designed to give safe anddependable service if operated according toinstructions.Read and understand the Owner’s Manualbefore operating the generator. Failure to doso could result in personal injury or equipmentdamage.

Exhaust contains poisonous carbon monoxide,a colorless, odorless gas. Breathing carbonmonoxide can cause loss of consciousnessand may lead to death.If you run the generator in an area that isconfined, or even partially enclosed area, theair you breathe could contain a dangerousamount of exhaust gas.Never run your generator inside a garage,house or near open windows or doors.

Connections for standby power to a building’selectrical system must be made by a qualifiedelectrician and must comply with allapplicable laws and electrical codes. Improperconnections can allow electrical current fromthe generator to backfeed into the utility lines.Such backfeed may electrocute utilitycompany workers or others who contact thelines during a power outage, and when utilitypower is restored, the generator may explode,burn, or cause fires in the building’s electricalsystem.

Do not connect to a building’s electricalsystem unless an isolation switch has beeninstalled by a qualified electrician.

08/10/21 20:21:11 32ZT7702_010

9

Stop the engine before refueling.Gasoline is extremely flammable and explosive under certainconditions. Refuel in a well ventilated area with the enginestopped.Keep away from cigarette, smoke and sparks when refuelingthe generator. Always refuel in a well ventilated location.

Never connect the different generator models and types.Wipe up spilled gasoline at once.

Never connect a cable other than the receptacle box for paralleloperation.

Connect and remove the receptacle box forparallel operation with the engine stopped.For single operation, the receptacle box forparallel operation must be removed.

A hot exhaust system can cause seriousburns.Avoid contact if the engine has beenrunning.

08/10/21 20:21:27 32ZT7702_011

10

U type

08/10/21 20:21:34 32ZT7702_012

11

CE mark and noise label locations

G, GW, B, F types

CE MARK and NOISE LABL

[Example: EU30is CE MARK and NOISE LABEL]

IP code

NOISE LABEL

Performance class

Dry mass (weight)

Manufacturer and address

08/10/21 20:21:39 32ZT7702_013

< >

< >

12

COMPONENT IDENTIFICATION3.

FRONT COVER

FRONT HANDLE PIPE

STARTER GRIP

GROUND TERMINALCONTROL PANEL(See page 14)

CONTROL PANEL(See page 14)

WHEELS

STAND TYPE

WHEEL TYPE

08/10/21 20:21:44 32ZT7702_014

13

MUFFLER FUEL FILLER CAP

SPARK PLUG CAP

AIR CLEANER

FRAME SERIAL NUMBER

OIL MAINTENANCE COVER

OIL FILLER CAP

REAR HANDLE PIPE

LEFT SIDE MAINTENANCE COVER

OIL DRAIN PLUG

Frame serial number:

Record the frame serial number in the space below. You will need thisserial number when ordering parts.

08/10/21 20:21:50 32ZT7702_015

14

DC CIRCUIT PROTECTOR

AC RECEPTACLESFUEL VALVE LEVER

CHOKE KNOB

ENGINE SWITCH

OIL ALERT INDICATOR LIGHT

AC RECEPTACLES AC RECEPTACLES

AC OUTPUT INDICATOR LIGHT

ECO THROTTLE SWITCH

AC OVERLOAD INDICATORLIGHT

PARALLEL OPERATION RECEPTACLE

DC RECEPTACLE

AC CIRCUIT PROTECTOR

CONTROL PANEL

F, G, GW types

B type U type

08/10/21 20:21:56 32ZT7702_016

15

Eco Throttle

ECO:

OFF:

OFF

ECO

OFF

ECO THROTTLE SWITCH

ECO

Engine speed is kept at idle automatically when the electricalappliance is disconnected and it returns to the proper speed by theelectrical load when electrical appliance is connected. This position isrecommended to minimize the fuel consumption while in operation.

Eco Throttle system does not operate sufficiently if the electricalappliance requires the momentary electric power.

Eco Throttle system does not operate. Engine speed is kept over ratedspeed.

When high electrical load appliances is connected simultaneously,turn the Eco Throttle switch to the OFF position to reduce voltagechanges.

08/10/21 20:22:04 32ZT7702_017

16

PRE-OPERATION CHECK4.

Be sure to check the generator on a level surface with the enginestopped.

Using non detergent oil or 2-stroke engine oil could shorten theengine’s service life.

Recommended oil

AMBIENT TEMPERATURE

Check the engine oil level.

Use 4-stroke motor oil that meets or exceeds the requirements for APIservice category SE or later (or equivalent). Always check the APIservice label on the oil container to be sure it includes the letters SE orlater (or equivalent).

SAE 10W-30 is recommended for general use. Other viscosities shownin the chart may be used when the average temperature in your area iswithin the indicated range.

1.

08/10/21 20:22:11 32ZT7702_018

17

Running the engine with insufficient oil can cause serious enginedamage.

OIL FILLER HOLE

OIL FILLER CAP

UPPER LEVELDIP STICK

OIL MAINTENANCECOVER

OIL FILLER CAP

Open the oil maintenance cover.Remove the oil filler cap, and wipe the dipstick with a clean rag. Checkthe oil level by inserting the dipstick in the filler hole without screwingit in.If the oil level is below the end of the dipstick, refill with recommendedoil up to the top of the oil filler neck.

The Oil Alert System will automatically stop the engine before the oillevel falls below the safe limit. However, to avoid the inconvenience ofan unexpected shutdown, it is still advisable to visually inspect the oillevel regularly.

08/10/21 20:22:18 32ZT7702_019

18

Gasoline is extremely flammable and is explosive under certainconditions.Refuel in a well ventilated area with the engine stopped. Do notsmoke or allow flames or sparks in the area where the engine isrefueled or where gasoline is stored.

Be careful not to spill fuel when refueling. Spilled fuel or fuel vapormay ignite. If any fuel is spilled, make sure the area is dry beforestarting the engine.Avoid repeated or prolonged contact with skin or breathing ofvapor.KEEP OUT OF REACH OF CHILDREN.

Do not overfill the fuel tank (there should be no fuel above theupper level mark). After refueling, make sure the fuel filler cap isclosed properly and securely.

LEVEL GAUGE

EMPTY

FULL

FUEL FILLER CAP

UPPER LEVEL MARK(RED)

Check the fuel level.

After refueling, tighten the fuel filler cap securely.Use automotive unleaded gasoline with a Research Octane Number of91 or higher (a Pump Octane Number of 86 or higher).Never use stale or contaminated gasoline or an oil/gasoline mixture.Avoid getting dirt or water in the fuel tank.

Check the fuel level gauge. Refill the fuel tank if the fuel level is low.

2.

08/10/21 20:22:32 32ZT7702_020

19

Gasolines Containing Alcohol

Gasoline spoils very quickly depending on factors such as lightexposure, temperature and time.In worst cases, gasoline can be contaminated within 30 days.Using contaminated gasoline can seriously damage the engine(carburetor clogged, valve stuck).Such damage due to spoiled fuel is disallowed from coverage by thewarranty.To avoid this please strictly follow these recommendations:

Only use specified gasoline (see page ).

If you notice any undesirable operating symptoms while using agasoline that contains alcohol, or one that you think containsalcohol, switch to a gasoline that you know does not contain alcohol.

Before buying fuel from an unfamiliar station, try to find out if thefuel contains alcohol, if it does, confirm the type and percentage ofalcohol used.

Honda cannot endorse the use of fuels containing methanol sinceevidence of their suitability is as yet incomplete.

Fuel system damage or engine performance problems resultingfrom the use of fuels that contain alcohol is not covered under thewarranty.

Do not use gasohol that contains more than 10% ethanol. Do not usegasoline containing methanol (methyl or wood alcohol) that does notalso contain cosolvents and corrosion inhibitors for methanol. Neveruse gasoline containing more than 5% methanol, even if it hascosolvents and corrosion inhibitors.

If you decide to use a gasoline containing alcohol (gasohol), be sure itsoctane rating is at least as high as that recommended by Honda. Thereare two types of ‘‘gasohol’’: one containing ethanol, and the othercontaining methanol.

If long storage (more than 30 days) is foreseen, drain fuel tank andcarburetor.

To slow deterioration, keep gasoline in a certified fuel container.Use fresh and clean gasoline.

18

08/10/21 20:22:44 32ZT7702_021

20

Never run the engine without the air cleaner element. Rapid enginewear will result from contaminants, such as dust and dirt, beingdrawn through the carburetor, into the engine.

PAPER ELEMENT

FOAM ELEMENT

AIR CLEANER COVER

CLIPS

AIR CLEANER COVER

Check the air cleaner.

Check the air cleaner elements to be sure they are clean and in goodcondition.Open the left side maintenance cover. Unsnap the four clips, removethe air cleaner cover, remove the foam element from the air cleanercover, and check the both elements.Clean or replace the element(s) if necessary (see page ).

3.

44

08/10/21 20:22:52 32ZT7702_022

21

STARTING THE ENGINE5.

Electric starting

When starting the generator after adding fuel for the first time, afterlong-term storage, or after running out of fuel, turn the fuel valvelever to the ON position, then wait for 10 to 20 seconds beforestarting the engine.

(EU30is only)

FUEL VALVE LEVER

ON

OONN

CLOSED

CHOKE KNOB

Turn the fuel valve lever to the ON position.

Before starting the engine disconnect any load from the AC receptacle.

Do not use the choke when the engine is warm or the air temperatureis high.

Pull the choke knob out to the CLOSED position.

1.

2.

08/10/21 20:23:01 32ZT7702_023

22

Do not use the starter motor for more than 5 seconds. If the enginefails to start, release the key, and wait at least 10 seconds beforeoperating the starter motor again.

ON

OFF START

OOFFFFOONN

SSTTAARRTT

ON

STARTOONN

SSTTAARRTT

ENGINE SWITCH

ENGINE SWITCH

Turn the engine switch to the START position and hold it there untilthe engine starts.

When the speed of the starter motor drops after a period of time, it isan indication that the battery should be recharged.

After the engine starts, let the engine switch return to the ONposition.

3.

4.

08/10/21 20:23:09 32ZT7702_024

23

OPEN

CHOKE KNOB

Push the choke knob to the OPEN position as the engine warms up.5.

08/10/21 20:23:13 32ZT7702_025

24

When starting the generator after adding fuel for the first time, afterlong-term storage, or after running out of fuel, turn the fuel valvelever to the ON position, then wait for 10 to 20 seconds beforestarting the engine.

Manual starting

FUEL VALVE LEVER

ON

OONN

CHOKE KNOB

CLOSED

Do not use the choke when the engine is warm or the air temperatureis high.

Before starting the engine disconnect any load from the AC receptacle.

Turn the fuel valve lever to the ON position.

Pull the choke knob out to the CLOSED position.

1.

2.

08/10/21 20:23:20 32ZT7702_026

< >

< >

25

ON

OFFOONN

ON

ENGINE SWITCH

ENGINE SWITCH

OFF

ON

OFF

OFF

EU30is

EU26is

Turn the engine switch to the ON position.3.

08/10/21 20:23:26 32ZT7702_027

26

Do not let the starter rope rub against the generator body, or therope will wear out prematurely.

Do not allow the starter grip to snap back. Return it slowly by hand.

The starter grip can be drawn back very quickly before you releaseit. This may pull your hand forcefully toward the engine and causean injury.

CHOKE KNOB

STARTER GRIP

OPEN

DDiirreeccttiioonn ttoo ppuullll

Pull the starter grip lightly until you feel resistance, then pull thestarter grip briskly toward in the direction of the arrow as shownbelow.

Push the choke knob to the OPEN position as the engine warms up.

4.

5.

08/10/21 20:23:34 32ZT7702_028

27

High altitude operation

Operation of the generator at an altitude lower than the carburetor isjetted for may result in reduced performance, overheating, andserious engine damage caused by an excessively lean air/fuel mixture.

At high altitude, the standard carburetor air-fuel mixture will beexcessively rich. Performance will decrease, and fuel consumption willincrease.

High altitude performance can be improved by specific modificationsto the carburetor. If you always operate the generator at altitudeshigher than 1,500 meters (5,000 feet) above sea level, have yourauthorized Honda dealer perform these carburetor modifications.

Even with suitable carburetor jetting, engine horsepower will decreaseapproximately 3.5% for each 300 meters (1,000 foot) increase inaltitude. The affect of altitude on the horse power will be greater thanthis if no carburetor modification is made.

08/10/21 20:23:39 32ZT7702_029

28

GENERATOR USE6.

Connections for standby power to a building’s electrical systemmust be made by a qualified electrician and must comply with allapplicable laws and electrical codes. Improper connections canallow electrical current from the generator to back feed into theutility lines. Such back feed may electrocute utility companyworkers or others who contact the lines during a power outage,and when utility power is restored, the generator may explode,burn, or cause fires in the building’s electrical system.

Do not connect to a building’s electrical system unless an isolationswitch has been installed by a qualified electrician.

EARTH MARK

GROUND TERMINAL

Be sure to ground the generator when the connected equipment isgrounded.

08/10/21 20:23:44 32ZT7702_030

29

Do not exceed the current limit specified for any one receptacle.Do not connect the generator to a household circuit. This couldcause the damage to the generator or to electrical appliances in thehouse.Do not modify or use the generator for other purposes than it isintended for. Also observe the following when using the generator.Do not connect an extension to the exhaust pipe.When an extension cable is required, be sure to use a tough rubbersheathed flexible cable (IEC 245 or equivalent).Limit length of extension cables; 60 m (200 feet) for cables of 1.5mm (0.0023 in ) and 100 m (330 feet) for cables of 2.5 mm (0.0039in ). Long extension cables will lower usable power due toresistance in the extension cable.Keep the generator away from other electric cables or wires such ascommercial power supply lines.

The DC receptacle can be used while the AC power is in use.If you use both at the same time, do not exceed the maximum ACpower.Maximum AC power:

In either case, the total power requirements (VA) of all appliancesconnected must be considered.

2.8 kVA2.4 kVA

For continuous operation, do not exceed the rated power.Rated power is:

3.0 kVA2.6 kVA

Limit operation requiring maximum power to 30 minutes.Maximum power is:

Make sure the electrical rating of the tool or appliance does notexceed that of the generator. Never exceed the maximum powerrating of the generator. Power levels between rated and maximummay be used for no more than 30 minutes.

Most appliance motors require more than their rated wattage forstartup.

2.25 kVA2.65 kVA

EU26i:EU30is:

EU26i:EU30is:

EU26i:EU30is:

08/10/21 20:23:58 32ZT7702_031

30

AC applications

Be sure that all appliances are in good working order beforeconnecting them to the generator. If an appliance begins to operateabnormally, becomes sluggish, or stops suddenly, turn off thegenerator engine switch immediately. Then disconnect theappliance, and examine it for signs of malfunction.

Substantial overloading that continuously lights the overloadindicator light (red) may damage the generator. Marginaloverloading that temporarily lights the overload indicator light (red)may shorten the service life of the generator.

OUTPUT INDICATORLIGHT (GREEN)

OVERLOAD INDICATORLIGHT (RED)

Start the engine and make sure the green output indicator comes on.

Confirm that the appliance to be used is switched off, and plug in theappliance.

1.

2.

08/10/21 20:24:06 32ZT7702_032

31

AC Circuit Protector (B, F, and GW Types)

AC CIRCUIT PROTECTOR(For receptacle No.1)

AC CIRCUIT PROTECTOR(For receptacle No.2)

AC RECEPTACLE No.1 AC RECEPTACLE No.2

The AC circuit protectors will automatically switch OFF (push buttoncomes out) if there is a short circuit or a significant overload of thegenerator at receptacle.If an AC circuit protector switches OFF automatically, check that theappliance is working properly and does not exceed the rated loadcapacity of the circuit before resetting the AC circuit protector ON(pushing the push button in).

08/10/21 20:24:12 32ZT7702_033

32

Output and Overload Indicators

OUTPUT INDICATOR LIGHT(GREEN)

OVERLOAD INDICATOR LIGHT(RED)

The Output indicator (green) will remain ON during normal operatingconditions.

Stop the engine if the Overload indicator (red) comes ON andinvestigate the overload source.

The Overload indicator (red) also lights in the following cases:When the inverter is overheated; the current to the connectedappliance will be shut off. Check to see if the air intake is obstructed.

When an electric motor is started, both the Overload indicator (red)and the Output indicator (green) may go on simultaneously. This isnormal if the Overload indicator (red) goes off after about five (5)seconds. If the Overload indicator (red) stays on, consult your Hondagenerator dealer.

Before connecting an appliance to the generator, check that it is ingood order, and that its electrical rating does not exceed that of thegenerator. Then connect the power cord of the appliance, and startthe engine.

If the generator is overloaded (see page ), or if there is a short in theconnected appliance, the Output indicator (green) will go OFF, theoverload indicator (red) will go ON and current to the connectedappliance will be shut off.

29

08/10/21 20:24:20 32ZT7702_034

33

Parallel operation

Substantial overloading that continuously lights the overloadindicator light (red) may damage the generator. Marginal overloadingthat temporarily lights the overload indicator light (red) may shortenthe service life of the generator.

SPECIAL CABLE/RECEPTACLE FORPARALLEL OPERATION(SOLD SEPARATELY)

PARALLEL OPERATION RECEPTACLE

Please read the item ‘‘GENERATOR USE’’ before connecting anyequipment to be used.

Make sure that the electrical rating of the tool or appliance does notexceed that of the generator. Never exceed the maximum powerrating of the generator. Power levels between rated and maximummay be used for no more than 30 minutes.

Limit operation requiring maximum power to 30 minutes.Maximum power in parallel operation is:

For continuous operation, do not exceed the rated power.Rated power in parallel operation is:

5,200 VA6,000 VA

4,800 VA5,600 VA

In either case, the total power requirements (VA) of all appliancesconnected must be considered.

Use only a special cable/receptacle for parallel operation (soldseparately).

EU30is:EU26i:

EU26i:EU30is:

08/10/21 20:24:31 32ZT7702_035

34

Never connect the different generator models and types.Never connect a cable other than the special cable/receptacle forparallel operation.Connect and remove the special cable/receptacle for paralleloperation with the engine stopped.For single operation, the special cable/receptacle for paralleloperation must be removed.

UNIT

SPECIAL CABLE/RECEPTACLE FORPARALLEL OPERATION

RECEPTACLE BOXUNIT

CABLE STRAP

FRONTHANDLEPIPE

Hang the receptacle box of the special cable/receptacle on the fronthandle pipe of unit or unit , and tie the longer cable of thespecial cable/receptacle to the front handle pipe of the other unitwith the cable strap.Connect the special cable/receptacle for parallel operation to the twogenerators.

1.

2.

08/10/21 20:24:39 32ZT7702_036

35

Confirm that the use equipment to be connected is switched off.When the equipment to be used is switched on, it will operatesuddenly, and injuries or accidents may be caused.

AC RECEPTACLE

GROUND TERMINAL

RECEPTACLE BOX

Start each engine according to ‘‘STARTING THE ENGINE’’.When the output indicator light (green) does not light and theoverload indicator light (red) lights instead, set the engine switchto STOP, stop the engine once, and then start the engine again.

Confirm that the equipment to be used is switched off, and insert theplug of the equipment to be used into the AC receptacle of thereceptacle box.

Be sure to ground the generator when the connected equipment isgrounded.

3.

4.

5.

08/10/21 20:24:46 32ZT7702_037

36

In case of normal operation In case of overload operation or short-circuit

OUTPUT INDICATOR LIGHT(RED)

OUTPUT INDICATOR LIGHT(GREEN)

Switch on the equipment to be used.The output indicator light (green) will light.

When electric power is to be taken again from the generator, switchoff the equipment to be used and remove the plug from the ACreceptacle. Confirm that the equipment and the connection arenormal and that not too much power is to be taken, and then startthe engine.

In case of overload operation (refer to page ) or when troubleoccurs for the equipment being used, the output indicator light(green) will go out, the overload indicator light (red) will lightcontinuously, and no power will be put out.At this time, the engine will not stop, so that the engine must bestopped by setting the respective engine switch to STOP.

The Overload indicator (red) also lights in the following cases:When the inverter is overheated; the current to the connectedappliance will be shut off. Check to see if the air intake is obstructed.When equipment requiring a large starting power, like a motor etc.,is used, the overload indicator light (red) and the output indicatorlight (green) may light together for a short time (about 4 sec), butthis is no abnormality. After start of the equipment, the overloadindicator light (red) will go out and the output indicator light (green)will stay lit.When the operation of one generator is to be stopped after start ofthe equipment, the special cable/receptacle for parallel operationalso must be removed at the same time.

6.

7.

32

08/10/21 20:24:56 32ZT7702_038

37

DC Application

DC Current

DC CIRCUIT PROTECTOR

ON OFF

(Example: EU26i)

CHARGING CABLE(SOLD SEPARATELY)

Connect the charging cable to the DC receptacle of the generatorand then to the battery terminals.

The DC receptacle may be used for charging 12 volt automotive-typebatteries only.

DC output will vary according to the position of the EcoThrottle switch.When the EcoThrottle switch is turned to the Eco position and the ACoutput is not used, the DC current will be about one-third of the ratedcurrent.

Eco

approximately 3.3 A

approximately 4 A

Eco throttle switch

Model

EU26i

EU30is

10 A

12 A

OFF(do not use the AC output)

1.

08/10/21 20:25:05 32ZT7702_039

--

38

To prevent the possibility of creating a spark near the battery,connect charging cable first to the generator, then to the battery.Disconnect cable first at the battery.Before connecting charging cable to a battery that is installed in avehicle, disconnect the vehicle’s battery cable. Reconnect thevehicle’s battery cable after the charging cables are removed. Thisprocedure will prevent the possibility of a short circuit and sparks ifyou make accidental contact between a battery terminal and thevehicle’s frame or body.

Do not attempt to start an automobile engine with the generatorstill connected to the battery. The generator may be damaged.Connect the positive battery terminal to the positive charging cord.Do not reverse the charging cables, or serious damage to thegenerator and/or battery may occur.

Batteries produce explosive gases: If ignited, and explosion cancause serious injury or blindness. Provide adequate ventilationwhen charging.CHEMICAL HAZARD: Battery electrolyte contains sulfuric acid.Contact with eyes or skin, even through clothing, may cause severeburns. Wear a face shield and protective clothing.Keep flames and sparks away, and do not smoke in the area.ANTIDOTE: If electrolyte gets into your eyes, flush thoroughly withwarm water for at least 15 minutes and call a physicianimmediately.POISON: Electrolyte is poison.ANTIDOTE

External: Flush thoroughly with water.Internal: Drink large quantities of water or milk.Follow with milk of magnesia or vegetable oil, and call aphysician immediately.

KEEP OUT OF REACH OF CHILDREN.

08/10/21 20:25:17 32ZT7702_040

39

Oil Alert system

OIL ALERT INDICATOR LIGHT (RED)

Start the engine.

The DC receptacle may be used while the AC power is in use.An overload DC circuit will trip the DC circuit protector (push buttoncomes out).If this happens, wait a few minutes before pushing in the circuitprotector to resume operation.

If the Oil Alert system shuts down the engine, the Oil Alert indicator(red) will come on when you operate the starter, and the engine willnot run. If this occurs, add engine oil (see page ).

The Oil Alert system is designed to prevent engine damage caused byan insufficient amount of oil in the crankcase. Before the oil level in thecrankcase falls below a safe limit, the Oil Alert system willautomatically shut down the engine (the engine switch will remain inthe ON position).

2.

16

08/10/21 20:25:24 32ZT7702_041

< >

< >

40

STOPPING THE ENGINE7.

IN NORMAL USE:

EU30is

EU26i

OFF

OFF

OFF

ENGINE SWITCH

ENGINE SWITCH

OFF

In parallel operation

To stop the engine in an emergency, turn the engine switch to the OFFposition.

Switch off the connected equipment and pull the inserted plug.

Turn the engine switch to the OFF position.

1.

2.

08/10/21 20:25:34 32ZT7702_042

41

FUEL VALVE LEVER

SPECIAL CABLE/RECEPTACLE FOR PARALLELOPERATION

OFF

OFF

Turn the fuel valve lever to the OFF position.

When parallel operation has been executed, remove the specialcable/receptacle for parallel operation.

3.

4.

08/10/21 20:25:40 32ZT7702_043

42

MAINTENANCE8.

Maintenance Schedule

Use Honda Genuine parts or their equivalent. The use of replacementparts which are not of equivalent quality may damage the generator.

Make sure the engine is off before you begin any maintenance orrepairs. This will eliminate several potential hazards:

Carbon monoxide poisoning from engine exhaust. Be sure there isadequate ventilation whenever you operate the engine.Burns from hot parts. Let the engine and exhaust system coolbefore touching.Injury from moving parts. Do not run the engine unless instructedto do so.

The muffler becomes very hot during operation and remains hot for awhile after stopping the engine. Be careful not to touch the mufflerwhile it is hot. Let the engine cool before maintenance.

The purpose of the maintenance and adjustment schedule is to keepthe generator in the best operating condition.Inspect or service as scheduled in the table below.

These items should be serviced by your Honda servicing dealer, unless you havethe proper tools and are mechanically proficient. Refer to the Honda shop manualfor service procedures.

Service more frequently when used in dusty areas.Replace paper element type only.

Engine oil

Air cleaner

Sediment cupSpark plug

Valve ClearanceCombustionchamberFuel tank & filterFuel line

Check levelChangeCheckCleanReplaceCleanCheck-adjustReplaceCheck-adjustClean

CleanCheck

Performed at every indicatedmonth or operating hour interval,whichever comes first.

ItemREGULAR SERVICE PERIOD (3) Each use

After every 500 hrs. (2)

Every 2 years (Replace if necessary) (2)

Firstmonth

or20 hrs.

Every3 months

or50 hrs.

(1)

Every6 months

or100 hrs.

Everyyearor

300 hrs.

(2)

(2)

For commercial use, log hours of operation to determine proper maintenanceintervals.

(1)(2)

(3)

08/10/21 20:25:56 32ZT7702_044

43

CHANGING OIL1.

ENGINE OIL CAPACITY:

OIL FILLER CAP

OIL DRAIN PLUGUPPER LEVEL

Open and remove the oil maintenance cover.Remove the oil filler cap and oil drain plug to drain the oil.Install the oil drain plug, and tighten it securely.Refill with the recommended oil (see page ) and check the oil level.Reinstall, close and latch the oil maintenance cover.

Wash your hands with soap and water after handling used oil.

Please dispose of used motor oil in a manner that is compatible withthe environment. We suggest you take it in a sealed container to yourlocal service station for reclamation. Do not throw it in the trash orpour it on the ground.

Drain the oil while the engine is still warm to assure rapid andcomplete draining.

0.55 L (0.58 US qt, 0.48 lmp qt)

1.2.3.4.5.

16

08/10/21 20:26:07 32ZT7702_045

44

AIR CLEANER SERVICE

Do not use gasoline or low flash point solvents for cleaning. Theyare flammable and explosive under certain conditions.

Never run the generator without the air cleaner. Rapid engine wearmay result.

2.

CLIPS

FOAM ELEMENT

AIR CLEANER COVER

CLIPSAIR CLEANER COVER

Open the left side maintenance cover.Unsnap the clips, remove the air cleaner cover.

Foam element:

Wash the foam element in asolution of household detergentand warm water, then rinset h o r o u g h l y , o r w a s h i nn o n f l a m m a b l e o r h i g hflashpoint solvent. Allow thefoam element to dry thoroughly.

Remove the foam element fromthe air cleaner cover.

A dirty air cleaner will restrict air flow to the carburetor. To preventcarburetor malfunction, service the air cleaner regularly. Servicemore frequently when operating the generator in extremely dustyareas.

3.

1.2.

a.

b.

08/10/21 20:26:18 32ZT7702_046

45

AIR CLEANER COVER

PAPER ELEMENT

Soak the foam element in cleanengine oil and squeeze out theexcess oil. The engine will smokeduring initial startup if too muchoil is left in the foam element.Reinstall the foam element to theair cleaner cover.

Paper element:If the paper element is dirty, replaceit with a new one. Do not clean thepaper element.

Reinstall the air cleaner cover.Close and latch the left sidemaintenance cover.

4.

c.

d.

6.5.

08/10/21 20:26:27 32ZT7702_047

46

FUEL SEDIMENT CUP SERVICE

Gasoline is extremely flammable and is explosive under certainconditions. Do not smoke or allow flames or sparks in the area.

3.

BREATHER HOSE

6 mm NUTS6 mm BOLT

AIR CLEANER BASE

The filter prevents dirt or water which may be in the fuel tank fromentering the carburetor. If the engine has not been run for a long time,the filter should be cleaned.

Turn the engine switch to the STOP position.Turn the fuel valve lever to the OFF position.Open the left side maintenance cover.Remove the air cleaner cover and paper element (see page and

).Disconnect the breather hose from the air cleaner base.Remove the 6 mm bolt and two 6 mm nuts, and remove the aircleaner base.

6.5.

2.3.4.

1.

4445

08/10/21 20:26:37 32ZT7702_048

47

After installing the sediment cup, be sure to tighten it securely. Checkfor fuel leaks and make sure the area is dry before starting the engine.

FILTER

RUBBER GASKET

SEDIMENT CUP

Remove the sediment cup by turning it counterclockwise.Clean the sediment cup, rubber gasket, and filter in nonflammableor high flash point solvent.Reassemble the filter, rubber gasket, and sediment cup. Tightensecurely.Reinstall the air cleaner base, and connect the breather gas hosewith the air cleaner base.Reinstall the paper element and air cleaner cover.Close and latch the left side maintenance cover.

7.8.

9.

10.

11.12.

08/10/21 20:26:47 32ZT7702_049

48

SPARK PLUG SERVICE4.

RECOMMENDED SPARK PLUG:

COVER SCREW

HANDLE BARPLUG WRENCH

SPARK PLUG CAP

SPARK PLUG INSPECTION COVER

To ensure proper engine operation, the spark plug must be properlygapped and free of deposits.

Remove the spark plug cap.Clean any dirt from around the spark plug base.Use a spark plug wrench to remove the spark plug.

Open the left side maintenance cover.Loosen the cover screw and remove the spark plug inspection cover.

BPR5ES (NGK)W16EPR-U (DENSO)

1.2.

3.4.5.

08/10/21 20:26:57 32ZT7702_050

- -

--

49

The spark plug must be securely tightened. An improperlytightened plug can become very hot and possibly damage thegenerator.Never use a spark plug with an improper heat range.

PLUG GAP

0.7 0.8 mm(0.028 0.031 in)

Visually inspect the spark plug. Discard it if the insulator is cracked,chipped, or fouled. Clean the spark plug with a wire brush if it is tobe reused.Measure the plug gap with a feeler gauge.Correct as necessary by carefully bending the side electrode.The gap should be:

Install the spark plug carefully, by hand, to avoid cross-threading.After a new spark plug has been seated by hand, it should betightened 1/2 turn with a wrench to compress its washer.If a used plug is being reinstalled, it should only require 1/8 to 1/4turn after being seated.Reinstall the spark plug inspection cover and tighten the coverscrew.Close and latch the left side maintenance cover.

0.7 0.8 mm (0.028 0.031 in)

6.

7.

8.9.

10.

11.

08/10/21 20:27:07 32ZT7702_051

50

FUSE REPLACEMENT

If frequent fuse failure occurs, determine the cause and correct theproblem before attempting to operate the generator further.Never use a fuse with a different rating from that specified. Seriousdamage to the electrical system or fire may result.

(EU30is only)5.

FRONT COVER

6 mm CAP NUTS

FUSE HOLDER COVER

If the fuse is blown, the starter motor will not work until it is replaced.

Turn the engine switch to the OFF position.Remove the four 6 mm cap nuts and the front cover.

Remove the fuse holder cover and replace the fuse.Specified fuse: 5 A

1.2.

3.

08/10/21 20:27:17 32ZT7702_052

-+

--

+-

51

BATTERY REMOVAL/INSTALLATION

Batteries produce explosive gases: If ignited, and explosion cancause serious injury or blindness. Provide adequate ventilationwhen charging.CHEMICAL HAZARD: Battery electrolyte contains sulfuric acid.Contact with eyes or skin, even through clothing, may cause severeburns. Wear a face shield and protective clothing.Keep flames and sparks away, and do not smoke in the area.ANTIDOTE: If electrolyte gets into your eyes, flush thoroughly withwarm water for at least 15 minutes and call a physicianimmediately.POISON: Electrolyte is poison.ANTIDOTE

External: Flush thoroughly with water.Internal: Drink large quantities of water or milk.Follow with milk of magnesia or vegetable oil, and call aphysician immediately.

KEEP OUT OF REACH OF CHILDREN.

Removal:

(EU30is only)6.

POSITIVE ( ) TERMINALNEGATIVE ( ) TERMINAL

BATTERY HOLDER BAND

BATTERY RUBBER

Turn the engine switch to the OFF position.Remove the four 6 mm cap nuts and the front cover. (see page )Remove the battery holder band.Disconnect the battery cable at the battery negative ( ) terminal,then at the battery positive ( ) terminal.

Remove the battery and the battery rubber from the battery tray.

1.2.3.4.

5.

51

08/10/21 20:27:32 32ZT7702_053

+ +-

-+ -

52

Installation:

When disconnecting the battery cable, be sure to disconnect at thebattery negative ( ) terminal first. To connect, connect at the positive( ) terminal first, then at the negative ( ) terminal. Never dis/connect the battery cable in the reverse order, or it causes a shortcircuit when a tool contacts the terminals.

Make sure that the engine switch is turned OFF.Connect the battery positive ( ) cable to the battery positive ( )terminal, then the battery negative ( ) cable to the battery negative( ) terminal. Tighten the bolts and nuts securely.Install the battery holder band.Install the front cover, and install the four 6 mm cap nuts.

This symbol on the battery means that this product must notbe treated as household waste.

Always confirm local regulations for battery disposal.

An improperly disposed of battery can be harmful to the environmentand human health.

1.2.

3.4.

08/10/21 20:27:42 32ZT7702_054

53

TRANSPORTING/STORAGE9.

When transporting the generator:Do not overfill the tank.Do not operate the generator while it is on a vehicle. Take thegenerator off the vehicle and use it in a well ventilated place.Avoid a place exposed to direct sunlight when putting thegenerator on a vehicle. If the generator is left in an enclosed vehiclefor many hours, high temperature inside the vehicle could causefuel to vaporize resulting in a possible explosion.Do not drive on a rough road for an extended period with thegenerator on board. If you must transport the generator on a roughroad, drain the fuel from the generator beforehand.

Gasoline is extremely flammable and is explosive under certainconditions. Perform this task in a well ventilated area with the enginestopped. Do not smoke or allow flames or sparks in the area duringthis procedure.

DRAIN SCREW

To prevent fuel spillage when transporting or during temporarystorage, the generator should be secured upright in its normaloperating position, with the engine switch OFF.The fuel valve lever should be turned OFF.

Drain the fuel.Be sure the storage area is free of excessive humidity and dust.

Before storing the unit for an extended period:

Open the left side maintenancecover.Turn fuel valve lever to ON andthen loosen the carburetordrain screw. Drain the gasolinefrom the carburetor and fueltank into a suitable container.Tighten the carburetor drainscrew, turn the fuel valve leverto OFF and close the left sidemaintenance cover.

1.2.

a.

b.

c.

08/10/21 20:27:54 32ZT7702_055

54

STARTER GRIP

Once a month, recharge the battery.Change the engine oil.Remove the spark plug and pour about a tablespoon of clean engineoil into the cylinder. Crank the engine several revolutions todistribute the oil, then reinstall the spark plug.Slowly pull the starter grip until resistance is felt. At this point, thepiston is coming up on its compression stroke and both the intakeand exhaust valves are closed. Storing the engine in this positionwill help to protect it from internal corrosion.

3.4.5.

6.

(EU30is only)

08/10/21 20:28:01 32ZT7702_056

55

TROUBLESHOOTING10.

When the engine will not start:

Is there fuel inthe tank?

Is the engineswitch ON?

Is the fuel valelever on?

Is the enough oilin the engine?

Turn the engineswitch ON.

Turn the fuelvalve lever on.

Refill the fueltank.

Is the spark plugin goodcondition?

Add therecommendedoil (see page ).

Clean, readjustgap and dry thespark plug.Replace it ifnecessary (seepage ).

If the engine stilldoes not start,take thegenerator to anauthorizedHonda dealer.

Turn on the fuel valvelever. Fuel should flowfrom the drain.

Turn off the fuel valvelever and loosen thedrain screw.

To check:

Is the fuelreaching thecarburetor?

Clean the fuelsediment cup(see page ).

NO

NO

NO

NO

NO

NO

1)

2)

YES

YES

YES

YES

YES

YES

16

48

46

08/10/21 20:28:17 32ZT7702_057

56

Appliance does not operate:

Take thegenerator to anauthorizedHonda dealer.

Turn the DCcircuit protectorON.

Is the DC circuitprotector ON?

No electricity at the DC receptacle:

Take theelectricalappliance orequipment toan electricalshop for repair.

Replace theelectricalappliance orequipment.

Check theelectricalappliance orequipment forany defects.

Take thegenerator to anauthorizedHonda dealer.

Is the Overloadindicator ON?

Is the outputindicator ON?

Is the AC circuit protectorON?

Take thegenerator to anauthorizedHonda dealer.

Turn the AC circuitprotector ON.

NO

NO

NO

YES

YES

YES

NO DEFECTS

DEFECTS

YES

(Except U type)NO

08/10/21 20:28:29 32ZT7702_058

× ××

--

57

SPECIFICATIONS11.

Dimensions and Weight

Engine

Generator

8.5:168.0 45.0 mm (2.7 in 1.8 in)

4-stroke, overhead valve, single cylinderGX160

EU26iEZGE

ModelDescription codeLength

Width

Height

Dry weight

658 mm (25.9 in)658 mm (25.9 in)447 mm (17.6 in)482 mm (19.0 in)558 mm (22.0 in)570 mm (22.4 in)

53.7 kg (118.4 lbs)55.9 kg (123.2 lbs)

163 cm (9.9 cu-in)

ModelType

ACoutput

DC rated outputOnly for charging 12 Vautomotive batteries.

12 V, 10 A

2.62.410.550

230F, G, GW, B

EU26i

ModelEngine typeDisplacementBore StrokeCompression ratioEngine speed

Cooling systemIgnition systemOil capacityFuel tank capacitySpark plug

W16EPR-U (DENSO)BPR5ES (NGK)

Transistor magnetoForced air

0.53 L (0.56 US qt, 0.47 lmp qt)13.3 L (3.51 US gal, 2.93 lmp gal)

(Stand type)(Wheel type)(Stand type)(Wheel type)(Stand type)(Wheel type)(Stand type)(Wheel type)

Rated Voltage (V)Rated Frequency (Hz)Rated Ampere (A)Rated Output (kVA)Max Output (kVA)

2,500 3,800 rpm

3,500 3,800 rpm (with eco throttle OFF)

08/10/21 20:28:50 32ZT7702_059

58

Noise

Microphone point

CONTROLPANEL

1.60 m

1.0 m

Center

EU26iModelType

Sound pressure level (Lp )According to 98/37/EC

Guaranteed sound power level(L ) Tested by 2000/14/EC

F, G, GW, B

90 dB

75 dBA

WA

‘‘the figures quoted are emission levels and are not necessarily safeworking levels. Whilst there is a correlation between the emission andexposure levels, this cannot be used reliably to determine whether ornot further precautions are required. Factors that influence the actuallevel of exposure of work-force include the characteristics of the workroom, the other sources of noise, etc. i.e. the number of machines andother adjacent processes, and the length of time for which an operatoris exposed to the noise. Also the permissible exposure level can varyfrom country. This information, however, will enable the user of themachine to make a better evaluation of the hazard and risk’’.

Specifications are subject to change without notice.

08/10/21 20:28:58 32ZT7702_060

× ××

--

59

Engine

Dimensions and Weight

Generator

8.5:168.0 54.0 mm (2.68 in 2.13 in)

4-stroke, overhead valve, single cylinderGX200

ModelDescription codeLength

Width

Height

Dry weight

EU30is

658 mm (25.9 in)658 mm (25.9 in)447 mm (17.6 in)482 mm (19.0 in)558 mm (22.0 in)570 mm (22.4 in)

59.0 kg (130.1 lbs)61.2 kg (134.9 lbs)

196 cm (12.0 cu-in)

EZGF

W16EPR-U (DENSO)BPR5ES (NGK)

Transistor magnetoForced air

0.55 L (0.58 US qt, 0.48 lmp qt)13.0 L (3.43 US gal, 2.86 lmp gal)

ModelType

ACoutput

DC rated outputOnly for charging 12 Vautomotive batteries.

12 V, 12 A

3.02.8

12.250

230

11.750

240UF, G, GW, B

EU30is

ModelEngine typeDisplacementBore StrokeCompression ratioEngine speed

Cooling systemIgnition systemOil capacityFuel tank capacitySpark plug

Battery 12 V 8.6 Ah/10 HR

2,500 3,800 rpm3,500 3,800 rpm (with eco throttle OFF)

(Wheel type)(Stand type)(Wheel type)

(Stand type)

(Wheel type)(Stand type)

(Stand type)(Wheel type)

Rated Voltage (V)Rated Frequency (Hz)Rated Ampere (A)Rated Output (kVA)Max Output (kVA)

09/03/04 12:28:04 32ZT7702_061

60

Noise

Microphone point

CONTROLPANEL

Center

1.0 m

1.60 m

EU30isF, G, GW, B U

ModelType

Sound pressure level (Lp )According to 98/37/EC

Guaranteed sound power level(L ) Tested by 2000/14/EC

91 dB

76 dBA

WA

‘‘the figures quoted are emission levels and are not necessarily safeworking levels. Whilst there is a correlation between the emission andexposure levels, this cannot be used reliably to determine whether ornot further precautions are required. Factors that influence the actuallevel of exposure of work-force include the characteristics of the workroom, the other sources of noise, etc. i.e. the number of machines andother adjacent processes, and the length of time for which an operatoris exposed to the noise. Also the permissible exposure level can varyfrom country. This information, however, will enable the user of themachine to make a better evaluation of the hazard and risk’’.

Specifications are subject to change without notice.

08/10/21 20:29:28 32ZT7702_062

61

WIRING DIAGRAM12.

AC Circuit ProtectorAC Noise FilterAC Output ReceptacleBatteryCharge WindingControl Panel BlockControl Panel GroundDC DiodeDC Noise FilterDC Circuit ProtectorDC WindingDC Output ReceptacleEco Throttle SwitchEngine BlockEngine GroundEngine SwitchFrame BlockFuseGenerator BlockGround TerminalIgnition CoilIgnition UnitInverter UnitMain WindingOil Level SwitchOil Alert IndicatorOverload IndicatorOutput IndicatorParallel Operation ReceptacleRegulatorSub WindingSpark PlugStarter MotorStepping MotorStarter Relay

ACCPACNFACORBATChWCPBCPGDCDDCNFDCCPDCWDCOREcoSwEgBEgGESwFrBFuGeBGTIgCIgUIUMWOLSwOALOlPLPORREGSWSPStMStpMStR

08/10/21 20:29:32 32ZT7702_063

62

BLACKYELLOWBLUEGREENREDWHITEBROWNLIGHT GREENGRAYLIGHT BLUEORANGEPINK

BlY

BuGRWBrLgGrLbOP

OFF

ENGINE SWITCH

EU26i

ON

IG E

EU30is

OFFONSTART

IG E BAT ST FS G

ECOTHROTTLE SWITCH

ONOFF

R/W R/Y ECOTHROTTLEOFFON

08/10/21 20:29:39 32ZT7702_064

63

EU26i: G, GW, B, F

08/10/21 20:29:46 32ZT7702_065

64

EU30is: G, GW, B, F

09/03/04 12:28:14 32ZT7702_066

65

EU30is: U

09/03/04 12:28:20 32ZT7702_067

66

RECEPTACLE

Shape Type

B

F

U

G, GW

08/10/21 20:30:14 32ZT7702_068

++

++

-++

++

++

++

+++

@@

++

++

++

67

MAJOR Honda DISTRIBUTOR ADDRESSES13.

AUSTRIA

BELGIUM

CROATIA

CYPRUS

FINLAND

FRANCE

GREECEDENMARKCANARY ISLANDS

BULGARIA CZECH REPUBLIC GERMANY

Honda Motor Europe (North)

Honda Motor Europe (North)

Hongoldonia d.o.o.

Alexander Dimitriou & Sons

Ltd.

OY Brandt AB.

HONDA RELATIONS CLIENTS

General Automotive Co S.A.Tima Products A/SAutomocion Canarias S.A.

Kirov Ltd. BG Technik cs, a.s. Honda Motor Europe (North)

GmbH

Hondastraße 1

2351 Wiener Neudorf

Tel. : 43 (0)2236 690 0

Fax : 43 (0)2236 690 480

http://www.honda.at

Doornveld 180-184

1731 Zellik

Tel. : 32 2620 10 00

Fax : 32 2620 10 01

http://www.honda.be

BH_PE HONDA-EU.

COM

Jelkovecka Cesta 5

10360 Sesvete Zagreb

Tel. : 385 1 2002053

Fax : 385 1 2020754

http://www.hongoldonia.hr

162, Yiannos Kranidiotis

Avenue

2235 Latsia, Nicosia

Tel. : 357 22 715 300

Fax : 357 22 715 400

Tuupakantie 7B

01740 Vantaa

Tel. : 358 20 775 7200

Fax : 358 9 878 5276

http://www.brandt.fi

TSA 80627

45146 St Jean de la Ruelle CEDEX

Tel. : 02 38 81 33 90

Fax : 02 38 81 33 91

http://www.honda.fr

relationsclientele.produits-

equipement honda-eu.com

71 Leoforos Athinon

10173 Athens

Tel. : 30 210 349 7809

Fax : 30 210 346 7329

http://www.honda.gr

info saracakis.gr

Tårnfalkevej 16 - Postboks 511

2650 Hvidovre

Tel. : 45 36 34 25 50

Fax : 45 36 77 16 30

http://www.tima.dk

Carretera General del Sur, KM.

8,8

38107 Santa Cruz de Tenerife

Tel. : 34 (922) 620 617

Fax : 34 (922) 618 042

http://www.aucasa.com

ventas aucasa.com

taller aucasa.com

49 Tsaritsa Yoana blvd

1324 Sofia

Tel. : 359 2 93 30 892

Fax : 359 2 93 30 814

http://www.kirov.net

honda kirov.net

U Zavodiste 251/8

15900 Prague 5 - Velka

Chuchle

Tel. : 420 2 838 70 850

Fax : 420 2 667 111 45

http://www.honda-stroje.cz

Sprendlinger Landstraße 166

63069 Offenbach am Main

Tel. : 49 69 8300 60

Fax : 49 69 8300 65100

http://www.honda.de

info post.honda.de

For further information, please contact Honda Customer Information Centreat the following address or telephone number:

08/10/21 20:30:28 32ZT7702_069

++

++

++

++

++

++

++

++

++

++

++

++

++

++

++

68

HUNGARY

IRELAND

ITALY

LATVIA

LITHUANIA

MALTA

NETHERLANDS

NORWAY

POLAND

PORTUGAL

REPUBLIC OFBELARUS

ROMANIA

RUSSIA

SERBIA &MONTENEGRO

SLOVAKIAREPUBLIC

Mo.Tor.Pedo Co Ltd.

Two Wheels Ltd.

Honda Italia Industriale S.p.A.

Bensons Auto

JP Motor Ltd

The Associated Motors

Company Ltd.

Honda Motor Europe (North)

Berema AS

Aries Power Equipment Sp. z

o.o.

Honda Portugal, S.A.

Scanlink Ltd.

Hit Power Motor Srl

Honda Motor Rus Llc

Bazis Grupa d.o.o.

Honda Slovakia, spol. s r.o.

Kamaraerdei ut 3.

2040 Budaors

Tel. : 36 23 444 971

Fax : 36 23 444 972

http://www.hondakisgepek.hu

info hondakisgepek.hu

Crosslands Business Park

Ballymount Road

Dublin 12

Tel. : 353 01 460 2111

Fax : 353 01 456 6539

http://www.hondaireland.ie

sales hondaireland.ie

Via della Cecchignola, 5/7

00143 Roma

Tel. : 848 846 632

Fax : 39 065 4928 400

http://www.hondaitalia.com

info.power honda-eu.com

Kr.Valdemara Street 21, 646

office

Riga, 1010

Tel. : 371 7 808 333

Fax : 371 7 808 332

http://www.honda-power.lv

Kubiliaus str. 6

08234 Vilnius

Tel. : 370 5 276 5259

Fax : 370 5 276 5250

http://www.hondapower.lt

New Street in San Gwakkin

Road

Mriehel Bypass, Mriehel QRM

17

Tel. : 356 21 498 561

Fax : 356 21 480 150

Afd. Power Equipment-

Capronilaan 1

1119 NN Schiphol-Rijk

Tel. : 31 20 7070000

Fax : 31 20 7070001

http://www.honda.nl

P.O. Box 454

1401 Ski

Tel. : 47 64 86 05 00

Fax : 47 64 86 05 49

http://www.berema.no

berema berema.no

ul. Wroclawska 25A

01-493 Warszawa

Tel. : 48 (22) 861 43 01

Fax : 48 (22) 861 43 02

http://www.hondapower.pl

info hondapower.pl

Abrunheira

2714-506 Sintra

Tel. : 351 21 915 53 33

Fax : 351 21 915 23 54

http://www.honda.pt

honda.produtos honda-

eu.com

Kozlova Drive, 9

220037 Minsk

Tel. : 375 172 999090

Fax : 375 172 999900

Calea Giulesti N° 6-8 Sector 6

060274 Bucuresti

Tel. : 40 21 637 04 58

Fax : 40 21 637 04 78

http://www.honda.ro

hit_power honda.ro

42/1-2, Bolshaya Yakimanka st.

117049, Moscow

Tel. : 74 95 745 20 80

Fax : 74 95 745 20 81

http://www.honda.co.ru

Grcica Milenka 39

11000 Belgrade

Tel. : 381 11 3820 300

Fax : 381 11 3820 301

http://www.hondasrbija.co.yu

Prievozská 6 - 821 09

Bratislava

Slovak Republic

Tel. : 421 2 32131112

Fax : 421 2 32131111

http://www.honda.sk

08/10/21 20:30:44 32ZT7702_070

++

++

++

++

++

++

++

69

SLOVENIA

SPAIN

SWEDEN

SWITZERLAND

UKRAINE

UNITED KINGDOM

TURKEY

AUSTRALIA

AS Domzale Moto Center D.O.

O.

Greens Power Products, S.L.

Honda Nordic AB

Honda Suisse S.A.

Honda Ukraine LLC

Honda (ULC) Power

Equipment

Anadolu Motor Uretim Ve

Pazarlama AS (ANPA)

Honda Australia Motorcycle

and Power Equipment Pty. Ltd

Blatnica 3A

1236 Trzin

Tel. : 386 1 562 22 42

Fax : 386 1 562 37 05

http://www.as-domzale-motoc.

si

Avda. Ramon Ciurans, 2

08530 La Garriga - Barcelona

Tel. : 34 3 860 50 25

Fax : 34 3 871 81 80

http://www.hondaencasa.com

Box 50583 - Västkustvägen 17

120215 Malmö

Tel. : 46 (0)40 600 23 07

Fax : 46 (0)40 600 23 19

http://www.honda.se

hpesinfo honda-eu.com

10, Route des Moulières

1214 Vemier - Genève

Tel. : 41 (0)22 939 09 09

Fax : 41 (0)22 939 09 97

http://www.honda.ch

101 Volodymyrska Str. - Build. 2

Kiev 01033

Tel. : 380 44 390 1414

Fax : 380 44 390 1410

http://www.honda.ua

470 London Road

Slough - Berkshire, SL3 8QY

Tel. : 44 (0)845 200 8000

Fax : 44 (0)1 753 590 732

http://www.honda.co.uk

customer.service

honda-eu.com

Esentepe mah. Anadolu

Cad. No: 5

Kartal 34870 Istanbul

Tel. : 90 216 389 59 60

Fax : 90 216 353 31 98

http://www.anadolumotor.com.tr

antor antor.com.tr

1954-1956 Hume Highway

Campbellfield Victoria 3061

Tel. : (03) 9270 1111

Fax : (03) 9270 1133

08/10/21 20:30:53 32ZT7702_071

08/10/21 20:30:55 32ZT7702_072