Lab Report (8)
Title: To check Colorfastness to Dry-cleaning
Submitted by
M. Abu Bakar Zafar 06-NTU-001
M. Afzaal Sadiq 06-NTU-077
Adnan Latif 06-NTU-103
Asad Jamil 06-NTU-107
Ali Asghar 06-NTU- 147
Submitted to
Sir. Qammar Zia
NATIONAL TEXTILE UNIVERSITY FAISALABAD
-
8/7/2019 06-77 lab 08 Quality and testing
2/6
2
Abstract:
In this practical determination of the colorfastness of textiles to dry-cleaning was done. Also the
multi fiber strip is evaluated for cross staining and its rating was done. This test method gives anindication of results to be obtained from three commercial dry-cleaning. These tests are very
important from quality control aspect.
-
8/7/2019 06-77 lab 08 Quality and testing
3/6
-
8/7/2019 06-77 lab 08 Quality and testing
4/6
4
1. Introduction1.1.Background:Dry cleaning is the cleaning of fabrics with organic solvents such as petroleum solvent,
perchloroethylene or fluorocarbon. This test method is intended for determining the
colorfastness of textiles to all kinds to dry cleaning. This test method gives an indication of
results to be obtained from three commercial dry cleanings.
1.2.Objective:
y To grade the sample obtained after dry cleaning.y To grade the staining check on multi fiber strip.
1.3.Theory:Fabric is washed with organic solvent under specified conditions and grading was done. The
multi fiber strip used to check staining rate consists of acetate, cotton, nylon, polyester and
acrylic.
2. Equipment and Materials:y Chromatic transference scaley Grey scale for stainingy Per chloro ethyleney Detergent solutiony Dry clean samplesy Original samplesy Multi fiber strip
3. Procedure:i. A bag was prepared for each specimen with inside dimensions of 1010 cm by using the
un-dyed cotton twill cloth by sewing together two squares of this cloth around three
sides.
-
8/7/2019 06-77 lab 08 Quality and testing
5/6
5
ii. The specimen and 10 steel balls were placed inside the bag and the bag was closed bysewing.
iii. Perchloroethylene & detergent solution was prepared by the following method.iv. A 1000 mL volumetric flask was filled partially with perchloroethylene and 10 mL of
detergent was added to it.
v.
Shaking was done to make the solution homogeneous.vi. Perchloroethylene was added to make the total volume up to 1000 mL.vii. 0.6 mL of water was added to the solution.
viii. Shaking was done until the solution was no longer cloudy.ix. 200 mL perchloroethylene detergent solution was added to a stainless steel container. The
bag containing the specimen and the steel discs was placed in container and the containerwas closed & was placed in washer for 30 min at 30 2C.
x. Rating of the color change of the test specimens was done using the Gray Scale for ColorChange.
xi. Then multi fiber strips were taken to check the staining rate. One the original multi fiberstrip and other the strip which was attached to sample during dry cleaning.
Sample
Rating
5 4 3 2 1
Excellent Poor
-
8/7/2019 06-77 lab 08 Quality and testing
6/6
6
4. Results:Orignal sample colour change grade = 4 5
Multifibre composition along with rating
Fibres Stain rating
Acetate 4-5
Cotton 4-5
Nylon 4-5
Polyester 4-5
Acrylic 4-5
wool 4-5
5. Discussion:The rating which ranges between 4-5 shows that fastness to dry cleaning and staining is verygood while when it gradually decreases, it shows the fastness is gradually becoming poor.
6. Conclusion:The given sample has very good color fastness to dry cleaning. It showed a very little change
in its color due to organic solvent. The rate of staining for each fabric was 4-5 which showed
very low staining.
7. References: AATCC manual 2009