Page 1: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

1

05/10/2004

MASTERMUX / USAMUX LAYOUTC.Guyot (Saclay)

Page 2: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

2

05/10/2004

MasterMux BO_A03-04:6 BOL 7 RasMux6 BOS 6 RasMux

MasterMux BM-Ref_A03-04:6 BML 6 RasMux6 BMS 6 RasMux

2 Ref-plate 2 RasMux

MasterMux BI_A03-04:6 BIL 6 RasMux7 BIS 7 RasMux

MasterMux BO_A05-06

MasterMux BM-Ref_A05-06

MasterMux BI_A05-06

Projective

Praxial

Reference

CCC RasMux

Sector 3A

Sector 5A

USAMux 1A zone

USAMux 2A zone

USAMux 3A zone

Multiplexing scheme(1)

Page 3: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

3

05/10/2004

MasterMux BO_A11b-12:3 BOL 4 RasMux

9 BOF/G 12 RasMuxMasterMux BM-Ref_A11-12:6 BML 6 RasMux6 BMS 6 RasMux

2 Ref-plate 2 RasMux

MasterMux BO_A13-14b:6 BOL 7 RasMux

7 BOF/G 9 RasMux

MasterMux BM-Ref_A13-14

Sector 11A

Sector 13A

USAMux 3A zone

MasterMux BI_A09-10-11a:6 BIL 6 RasMux7 BIS 7 RasMux3 BIM 3 RasMux

MasterMux BI_A13-14-15a:7 BIS 7 RasMux6 BIL 6 RasMux3 BIR 3 RasMux

RasMux

USAMux 2A zone

USAMux 1A zone

Projective

Praxial

Reference

CCC

BIR-BIMMasterMux BI_A15b-16

7 BIS 7 RasMux5 BIM 5 RasMux3 BIR 3 RasMux

MasterMux BI_A11b-12:2 BIM 2 RasMux6 BIR 6 RasMux7 BIS 7 RasMux

Multiplexing scheme(2)

Page 4: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

4

05/10/2004

BOL1 BOL2 BOL3 BOL4 BOL5 BOL6

BOS1 BOS2 BOS3 BOS4 BOS5 BOS6

RasMux

Example of RasMux-MasterMux connections

Mas

terM

ux

Page 5: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

5

05/10/2004

MasterMux Locations and cable routing(standard sectors)

MasterMux BO

MasterMux BM-ref

MasterMux BI

RasMux

Page 6: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

6

05/10/2004

Sector 1

MasterMux Locations

MasterMux BO

MasterMux BM-ref

MasterMux BI

Page 7: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

7

05/10/2004

USAMux 1A zone

USAMux 3A zone

USAMux 2A zone

Spectrometer zones covered by each USAMux

Page 8: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

8

05/10/2004

USAMux 1 side A:

8 MasterMux:•BO_A03-04•BO_A01-02•BO_A14b-15-16•BO_A13-14a•BI_A03-04•BI_A01-02•BI_A15b-16•BI_A13-14-15a

MasterMux BI_A15b-16: BIS-16A-1/7 7 RasMux BIM-15A-1/5 5 RasMux BIR-15A-4/6 3 RasMux

MasterMux BI_A13-14-15a BIR-15A-1/3 3 RasMux BIS-14A-1/7 7 RasMux BIL-13A-1/6 6 RasMux

MasterMux BO_A13-14b: BOL-13A-1/6 7 RasMux BOF/G-14A-2/8* 9 RasMux

*: BOG0 is equipped with 2 RasMux, for the A and C side sensors

BOG2-4-6 are equipped with 2 RasMux (4 in-plane rascam)

MasterMux BO_A14a-15-16: BOF/G-14A-0/2* 3 RasMux BOL-15A-1/6 7 RasMux BOS-16A-1/6 6 RasMux

Page 9: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

9

05/10/2004

USAMux 2 side A:

8 MasterMux:•BO_A05-06•BO_A07-08•BO_A09-10-11a•BO_A11b-12•BI_A05-06•BI_A07-08•BI_A09-10-11a•BI_A11b-12

MasterMux BI_A11b-12: BIM-11A-4/5 2 RasMux BIR-11A-1/6 6 RasMux BIS-12A-1/7 7 RasMux

MasterMux BI_A09-10-11a: BIL-09A-1/6 6 RasMux BIS-10A-1/7 7 RasMux BIM-11A-1/3 3 RasMux

MasterMux BO_A11b-12: BOL-11A-4/6 4 RasMux BOF/G-12A-0/8* 12 RasMux

USAMux 3 side A:

8 MasterMux:•BM-REF_A01-02•BM-REF_A03-04•BM-REF_A05-06•BM-REF_A07-08•BM-REF_A09-10•BM-REF_A11-12•BM-REF_A13-14•BM-REF_A15-16

+ idem Side C

MasterMux BO_A09-10-11a: BOL-09A-1/6 7 RasMux BOS-10A-1-6 6 RasMux BOL-11A-1/3 3 RasMux

*: BOG0 is equipped with 2 RasMux, for the A and C side sensors

BOG2-4-6 are equipped with 2 RasMux (4 in-plane rascam)

Page 10: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

10

05/10/2004

Special connections: RASNIKs spanning over 2 different USAMux

Praxials: BIS-nA-1 BIS-nC-1 2 praxials * 8 sectors BMS-nA-1 BMS-nC-1 2 praxials * 6 sectors BOS-nA-1 BOS-nC-1 2 praxials * 6 sectors

Reference systems: Ref plates A BIL-nA-4/6 – BIR-11/15A-3/6 2 refs*8 sectors Ref plates C BIL-nC-4/6 – BIR-11/15C-3/6 2 refs*8 sectors

CCCs: BIS-04A-1/4/7 BIL-05A-1/3/6 3 CCC BIS-12A-1/4/7 BIL-13A-1/3/6 3 CCC BOS-04A-2/5 BOL-05A-1/5 2 CCC BOF-12A-1/7 BOL-13A-1/5 2 CCC

Nb: camera led

+ idem side C =>20 CCC

40 praxials = 80 rasniks

32 Refs

Total: 132 special camera-led connections

Page 11: 05/10/2004 1 MASTERMUX / USAMUX LAYOUT C.Guyot (Saclay)

11

05/10/2004

Number of elements:

 BIS (one per chamber, BIS8 inplane on BIS7 rasmux) :      112  BIL (one per chamber, 6 sectors)              :        72  BIM                             :        20  BIR                            :        24  BML (no BML4 in sector 13)                         :        94  BML4-sector 13 (fake frame done at Saclay)       :          2  BMS (one per chamber, 6 sectors)                   :        72  BMF (2 sectors)                                    :        12  BOL (one per chamber except BOL4 with 2)       : 96+16= 112  BOS (one per chamber)                              :        72  BOF-BOG (BOG0-2-4-6 with 2)  : 32+16=48  BOL fake frame in sector 13 (Saclay)                :      2  Reference plates on toroid ribs (Saclay)               :    32  BEE (one for 2 adjacent, not decided yet)                     :    16(?) -----------------------------------------------------------------------------  Total RASMUX                                            :       690

RASMUX

48 MasterMux

6 USAMux

+ 1 MasterMux per EC toroid (?) (16 BEE=>8RasMux)

1 additionnal USAMux (?)

ATLAS total: 50 MasterMux, 7 USAMux