02 - making c2 your own
TRANSCRIPT
-
CAUExpress2013 1
TailoringCAESARIIDavidDiehl
Intergraph 2013
CAESAR II
Making CAESAR II your Own
Intergraph 2013
Introduction
A majority of time allocated to pipe stress analysis is used in building models
Many users use the software right out of the box even though there are many ways to improve input ease and efficiency Screen organization Program content Default settings Display Output Display and Management
-
CAUExpress2013 2
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Structure/Organization
Executables - 1(the program)
System folder - 2 Registry Data Folders - 3
[Registry]
C:\Program Files (x86)
\Intergraph CAS\CAESAR II 2013 R1
x1x\ProgramData
\Intergraph CAS\CAESAR II
\6.10\SYSTEM
x2x\Data Folders
x3x
Intergraph 2013
Program Structure
Executables(the program) C:\Program Files (x86)
\Intergraph CAS\CAESAR II 2013 R1
No reason to touch this
-
CAUExpress2013 3
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Structure
System folder C:\Program Data
\Intergraph CAS\CAESAR II\6.10\System
These files are under your control
Intergraph 2013
Program Structure
System folder Data
(.FIL) Units (.FAT) Fatigue data (.FLG) Flange rating [ASME-
2003.G gasket diameter] (.EQL) Equipment data (.FRP) Fiberglass data (.UMD) User Materials C2RPTTMPL.XML stores
custom output reports
-
CAUExpress2013 4
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Structure
System folder Control
(.INP) Input report format (CAESAR.CFG)
Configuration file
Intergraph 2013
Program Structure
Registry Manages screen presentation (e.g. Element List) Do not fool around here!
-
CAUExpress2013 5
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Structure
Data Folders Use to segregate
projects Different settings to
override defaults supplied by SYSTEM
Set local control CAESAR.CFG
(configuration) Set local units
UNITS.FIL
Intergraph 2013
Data Sources for CAESAR II
Control switches Configuration File (current folder or System)
Program content Material data (program and user data) Nominal values Valve/Flange Data; Expansion Joint Modeler
The piping model Special Execution Parameters And, of course, your input model
-
CAUExpress2013 6
TailoringCAESARIIDavidDiehl
Intergraph 2013
The CAESAR II Configuration (CFG) File
The Configuration File (i.e. CAESAR.CFG) holds many general CAESAR II settings
A program installation dialog will establish the CFG file and store it in SYSTEM
If no CFG in the local folder, CAESAR II will use the SYSTEM CFG
Any changes to CFG in the local folder are stored locally
Use separate folders to separate differing CAESAR II settings
Intergraph 2013
The CAESAR II Configuration (CFG) File
Many program settings/switches are controlled in the configuration file.
Be aware of when the change occurs (activation point):
-
CAUExpress2013 7
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Input Display
This is the initial screen layout with toolbars all around!
This window area contains the model graphic; there is no piping input spreadsheet here.
The piping input is currently rolled up in a tab.
Intergraph 2013
Program Input Display
Toolbars My choice:
or build
your own!
-
CAUExpress2013 8
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Input Display
Building a Custom Toolbar
Intergraph 2013
Program Input Display
Relocating Tools
-
CAUExpress2013 9
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Input Display
Update graphics (stored in CFG & Registry)
Intergraph 2013
Program Input Display
Locating the Piping Input Spreadsheet
-
CAUExpress2013 10
TailoringCAESARIIDavidDiehl
Intergraph 2013
Program Input Display
Using Tearables
Intergraph 2013
Program Input Display
Adjusting plot update CAESAR II will update the plot after each new
element is entered to include the entire model using the default view (southeast)
If you wish to stay focused on a particular section, turn off Refresh (This is automatically off on a return to an existing model.)
Very large models may take time to update. You may wish to turn off plot update altogether.
-
CAUExpress2013 11
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content
Material data Fatigue, equipment, flange, FRP Valve/Flange data Displacement sets Dynamic data
Intergraph 2013
Editing/Adding Stored Content- Material Data
CAESAR II has hundreds of materials But maybe not yours You can define these materials locally:
-
CAUExpress2013 12
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Material Data
Or, you can add your material to the CAESAR II database
Edit
Erase
Save
Intergraph 2013
Editing/Adding Stored Content- Material Data
Note that if you are creating a unique name, build it as All Codes (then follow with a specific Code, if desired)
Edit, then Search
Different data for different Codes
-
CAUExpress2013 13
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Material Data
Edit then Save
Intergraph 2013
Editing/Adding Stored Content- Material Data
Your work will not alter the CAESAR II data (stored in CMAT.BIN)
Instead, your data (stored in UMAT1.UMB) will overlay any existing data
These files reside in SYSTEM:
-
CAUExpress2013 14
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Fatigue, Equipment, Flange, FRP
Data sets in SYSTEM can be added or edited Fatigue Curves - *.FAT Equipment Limits - *.EQL Flange Classification - *.FLG Fiberglass Material Data - *.FRP
Intergraph 2013
Editing/Adding Stored Content- Fatigue, Equipment, Flange, FRP
Formats are similar Lines beginning with an asterisk are comments Every table has a multiplier for use as units conversion
or other factors (e.g. safety) Here is a set of fatigue data:
N S
-
CAUExpress2013 15
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Valve/Flange Data
Data Structure Class identifies
Specification
Intergraph 2013
Editing/Adding Stored Content- Valve/Flange Data
Data Structure Spec points to the
data file
Here, flanged 150 Class gate valve data (1 - 30) is found in \150 in the file GAT_F
-
CAUExpress2013 16
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Valve/Flange Data
Data Structure You can edit this data
Here, flanged 150 Class gate valve data (1 - 30) is found in \LIB_I\150 in the file GAT_F
Intergraph 2013
Editing/Adding Stored Content- Valve/Flange Data
Edit data (Weights are generic)
-
CAUExpress2013 17
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Displacement Sets
Modular piping offshore can have many imposed displacements at many connection points requiring many displacement sets
This data entry can be automated
Intergraph 2013
Editing/Adding Stored Content- Displacement Sets Example
-
CAUExpress2013 18
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Displacement Sets Example
Edit the .CSV file in Excel. Here, identify labels and enter the additional displacement sets.
Intergraph 2013
Editing/Adding Stored Content- Displacement Sets Example
(Existing data sets table layout)
New data
Import modified data set
-
CAUExpress2013 19
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Dynamic Data
Applied dynamic loads in the form of response spectra and time histories can carry large amounts of data
Response spectra apply to all piping on a single floor of a structure or to and entire plant area building once and using often is an efficient approach
Transient hydraulic analysis tools can develop massive amounts of load vs. time data for direct use as CAESAR II input.
Intergraph 2013
Editing/Adding Stored Content- Dynamic Data
CAESAR II provides methods to store these dynamic data sets
This dynamic data, whether provided by the structures group, process engineers or produced by CAESAR II, can be stored on the hard drive and attached to any set of dynamic input.
-
CAUExpress2013 20
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Response Spectrum Data
A response spectrum data set is shown here
Two columns of data: period vs. g
Comment lines begin with an asterisk
Intergraph 2013
Editing/Adding Stored Content- Response Spectrum Data
The response spectrum data can be linked to the dynamic input.
Here is the processed data.
The hash in front of the name indicates read from file.
-
CAUExpress2013 21
TailoringCAESARIIDavidDiehl
Intergraph 2013
Editing/Adding Stored Content- Response Spectrum Data
The response spectrum data can be read in directly.
This button will open the processor to acquire the data.
Spectrum name identifies the two columns of data.
Click here to bring in the data. Select the
data source.
Intergraph 2013
Editing/Adding Stored Content- Response Spectrum Data
Site or floor data for use in many CAESAR II models.
-
CAUExpress2013 22
TailoringCAESARIIDavidDiehl
Intergraph 2013
Building standard load case lists
Many firms have standardized their load sets In more and more instances, these are very
comprehensiveSeismic, wind, blastFPSOFatigue
and therefor, tedious and prone to error You can copy existing load cases from one job
to another
Intergraph 2013
Using Standard Load Case Sets
-
CAUExpress2013 23
TailoringCAESARIIDavidDiehl
Intergraph 2013
Using Standard Load Case Sets
Intergraph 2013
Using Standard Load Case Sets
-
CAUExpress2013 24
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output
Graphics display Input Echo Sorting output Custom reports Table display using MS Word Post processing results
Intergraph 2013
Output Graphics Display
The overstress plot can be tuned in both color and the percentage (of allowable stress) it represents
-
CAUExpress2013 25
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Graphics Display
Default Edited
>90% is blue
-
CAUExpress2013 26
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Input Echo
The INP files set the format for the input lists. Here is the beginning of the default element report
format (ELEMENT.INP & ELEMENT0.INP):
Intergraph 2013
Output Input Echo
Here is another ELEMENT1.INP:
-
CAUExpress2013 27
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Input Echo
CAESAR II uses the base .INP file without a numeric suffix (e.g. ELEMENT.INP)
The files with the numeric suffix are available for use (e.g. ELEMENT1.INP)
You can build your own format files as well Copy the selected file into the base name to
apply
Intergraph 2013
Output Input Echo Example
Selecting the Element List
-
CAUExpress2013 28
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Input Echo Example
Using ELEMENT.INP (duplicate: ELEMENT0.INP)
Intergraph 2013
Output Input Echo Example
Copying ELEMENT1.INP into ELEMENT.INP
-
CAUExpress2013 29
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Sorting Output
Using node labels
Choose your display
Select Node Name under Options
Intergraph 2013
Output Sorting Output
Sorting displayed results Simply double-click once or twice on a column
heading:Original (sort by element) 1st double-click on ratio (small to big)2nd double-click on ratio (big to small)
-
CAUExpress2013 30
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Sorting Output
Very large models have too much data to review Reduce scrolling by adding filters to the output
report:
Intergraph 2013
Output Sorting Output
Using filters
The entire, filtered, report
Filter displayed
-
CAUExpress2013 31
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Custom Reports
Combine results in your own reports In this example the global X, Y, Z
displacements will be displayed in terms of South (X), West (Z), and Up (Y)
N
EX
YZ
versus
Intergraph 2013
Output Custom Reports
Combine results in your own reports Start by clicking on Add new custom report
template
-
CAUExpress2013 32
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Custom Reports
Define your report content & format
Sample Display
Displacement in X will be in the first
column (after node), it will be
labeled South, Z is next, then Y
Identify report type
and title
Define titles (default)
Intergraph 2013
Output Custom Reports
Using your reports
-
CAUExpress2013 33
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Table Display using MS Word
You can control the style of tables in MS Word by manipulating OutWord.DOT (a template file) found in the CAESAR II SYSTEM folder
Set your table style and save as OutWord.DOTM
Intergraph 2013
Output Table Display using MS Word
: Default table format
Updated table format (stored in
OutWord.DOTM) :
-
CAUExpress2013 34
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Post Processing Results
Post processing in MS Excel or MS Access allows you to manipulate results outside of CAESAR II
Here we will confirm the B31.1 expansion stress range formula used by CAESAR II
Intergraph 2013
Output Post Processing Results
Generate the local element force and stress report
-
CAUExpress2013 35
TailoringCAESARIIDavidDiehl
Intergraph 2013
Output Post Processing Results
Output now in MS Excel
Intergraph 2013
Output Post Processing Results
Use those lists to perform additional calculationHere, comparing a hand calculation to CAESAR II reported stress:
-
CAUExpress2013 36
TailoringCAESARIIDavidDiehl
Intergraph 2013
Making CAESAR II your Own
In this session we tailored:Screen organizationProgram contentDefault settingsDisplay Output Display and Management
Intergraph 2013
Making CAESAR II your Own
Questions? Comments?
-
CAUExpress2013 37
TailoringCAESARIIDavidDiehl
Intergraph 2013
Making CAESAR II your Own
Thank You