-the premier supplier of bwt...
TRANSCRIPT
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
The information contained in this presentation is confidential and for the use of the intended
participants only. This presentation and its contents should not be copied, distributed or otherwise
made available to unintended parties.
- The Premier Supplier of BWT Expertise -
BWM Tech North America September 2016
<Provalys> LNGc retrofit
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver - The Premier Supplier of BWT Expertise
• Norwegian, founded in 2003
• Headquarters in Norway
• Assembly in Norway
• Ballast water treatment is our sole focus
• Patented core technology
• Employees from marine / offshore industry
• Lloyds Register ISO 9001:2008 Certified
• Mission:
Protecting the marine environment by supplying IMO, USCG and Class Certified Ballast Water
Treatment Systems
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver - Worldwide BWTS supplier with a local footprint
• OceanSaver, Total 99 employees
• Office Pusan, Korea
• Office Shanghai, China
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
Order references – 09.2016
Vessel Type BWTS Capacity System OrdersVLCC/Suezmax 2 x 3000 / 2500 m3/h MK I 21 Korea (HHI & DSME) & China (DSIC & SWS)
Suezmax 2 x 2500 m3/h MK I 2 Korea (HHI)
PCTC 2 x 600 m3/h MK I 2 Retrofit (China)
VLCC 2 x 3000 m3/h MK II 7 Korea (STX & DSME) & China (RSHI)
VLCC 1 x 3500 m3/h MK II 2 Japan (JMU)
Suezmax 2 x 2500 m3/h MK II 7 Korea (SHI & BSHI)
Aframax LR 1 & 2 2 x 2000 m3/h MK II 10 China ( COSCO & GSI)
Aframax LR 1 & 2 2 x 1800 m3/h MK II 4 Korea (Daehan)
Aframax LR 1 & 2 2 x 1500 m3/h MK II 2 Korea (HSHI)
Aframax LR 1 & 2 2 x 1000 m3/h MK II 6 Korea (STX)
Product / Chemical 2 x 1100 / 1000 m3/h MK II 4 Japan (Onomichi) & Korea (STX)
Product / Chemical 2 x 750 / 800 m3/h MK II 10 Korea (HMD & STX)
Bulk Carrier 2 x 3000 / 2500 m3/h MK II 23 China & Korea
Bulk Carrier 2 x 2000 m3/h MK II 1 Retrofit (China)
Bulk Carrier 2 x 1500 m3/h MK II 15 Japan (Oshima) & China (Hudong)
Bulk Carrier 2 x 1200 m3/h MK II 1 China (JEHI)
Bulk Carrier 2 x 800 m3/h MK II 8 Japan (Oshima) & Korea (SPP)
Bulk Carrier 1 x 800/ 830 / 1200 m3/h MK II 9 Japan (Oshima)
LNG 2 x 3000 m3/h MK II 2 Korea (DSME)
LNG 2 x 3200 / 3000 m3/h MK II 7 Retrofit (Singapore, Spain & Qatar)
LNG 2 x 3100 m3/h MK II 12 Korea (DSME)
LNG 2 x 2700 / 2500 m3/h MK II 6 China (Hudong) & Korea (HHI)
LPG 2 x 800 m3/h MK II
18 China (Shanghai) & Korea (HHI & HSHI) + 1
Retrofit (Singapore)
Total Newbuilding 170
Total Retrofit 11
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
USCG Certificate – StatusApproval documentation submitted to the USCG September 23rd 2016
Status
5 salinity water tests
5 brackish water tests
5 fresh water tests
5 Ship-board tests
Test vessel MV Sheila Ann
9 MH filter tests
Filters
Vibration,
humidity/dust,
movement,
electricity
stability
Landbased tests
Shipboard tests
Component tests
Control cabinets
Rectifiers
TRO Monitors
Flowmeters
Completed –Along the vessels trade route
West Coast of US / Canada / Mexico
Completed at DHI, Denmark
• Completed at Applica, Norway
• Documentation Process in
cooperation with DNV-GL
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver - Mark II BWTS
Filtration
Disinfection
• 40 micron screen filter
• Automatic self-cleaning
• Filter capacity 50 – 3.500 m3/h
• Well proven technology developed for
BWTS application
• Onboard oxidant
• Efficient – maximum 2.5 ppm to
ballast tanks
• Rapid decay of TRO
• Self-adjusted dosage level
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
The information contained in this presentation is confidential and for the use of the intended
participants only. This presentation and its contents should not be copied, distributed or otherwise
made available to unintended parties.
C2E Feed filter
C2E
Feed
pump
Disinfectant
Ballast pump
Sea Chest
Main filter
C2E Unit with
heater
H2 Exhaust fan
A.P Tank
Treatment
Spool Unit
TRO
sensor
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
The information contained in this presentation is confidential and for the use of the intended
participants only. This presentation and its contents should not be copied, distributed or otherwise
made available to unintended parties.
C2E Feed filter
C2E
Feed
pump
Disinfectant
Ballast pump
Sea Chest
Main filter
C2E Unit with
heater
H2 Exhaust fan
TRO-N
Stand-by
unit
TRO
sensor
A.P Tank
Treatment
Spool Unit
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Key aspects of any retrofit project
• Contract signing, 6-12 months before
installation
• Kick-off meeting
• 3D scanning of vessel
• Clear allocation of responsibilities and
accountabilities between involved parties
• Active involvement from owners
representative
• Communication between BWTS Supplier,
Engineering Design Firm and owner
throughout entire project
• Weekly/bi-weekly tele-conference with
status updates
• Detailed work scope package
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project Models
Project Model 1
Vessel Owner
BWTS Supplier
Engineering Design Firm
Installation Yard
Project Model 2
Vessel owner
BWTS Supplier
Engineering Design firm
Installation Yard
Project execution will be similar – the project models describe general
breakdown of responsibilities and accountabilities of each party
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
Project Manager
Vessel Superintendent
Project Manager
Lead Mechanical Engineer
Electrical Engineer
Commissioning
EngineerQA
Project Manager / Technical Coordinator
Piping Lead
Piping Team
Structural Lead / NA
Electrical Engineer
HSE
Project Management – Dedicated resources
OceanSaver Engineering partner
Ship-owner
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
Vessel Owner
BWTS Supplier
OceanSaver
Design Firm
Harris Pye
Installation Yard
Singapore
OceanSaver – Retrofit Project “Provalys” LNGc
Project Model
Vessel Type: LNG Carrier
BWTS Capacity: 2x3000 cbm/hr
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
Pre-Engineering Detailed Engineering Installation and Commissioning
June 2015
Tender issued
July 2015
3D scan / onboard
survey as part of tender
October 2015
Official contract signing
New 3D scan / survey
November 2015
Start of detailed
design /engineering
April 2016
Design freeze and
Meeting with Class
May 2016
Tender for BWTS
installation / DD floated
Sept / Oct 2016
Installation and
commissioning of
OceanSaver BWTS
Total Project timeframe – Abt 12 Months
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
Tender Survey & 3D scanning;
• Locations for main equipment
– Filters, Disinfectant units etc
• Vessel Documentation
• Contract negotiation
– Dedicated Project team members
(Owner/OS/Engineering partner)
– Importance of Engineering partners
knowledge/experience with <OS-BWTS>
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
• Official contract signing, End of October 2015.
New 3D scan / survey executed by Harris Pye / OceanSaver
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
DETAILED ENGINEERING PHASE – November 2015 – February 2016
– 3D Model based on OceanSaver Working Documentation
– Weekly Design review and feedback with Owner / Harris Pye
• MOM that covers all actions and items under review
• Project Plan updated continuously
• Offices in three time zones – Communication / Sharing platform (FTP server)
– Conference call
– Team viewer
– Skype
– Design Freeze
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
• Meeting with Class, April 2016
• BV Paris Office
– Class Comments for review
– Piping spec GRE / GRP
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
• Tender for BWTS installation / Dry Docking floated
– Detailed Scope of Work developed in cooperation <Harris Pye / Owner / OS>
• Including installation methodology
– Keppel Singapore eventually selected as yard, Delivery place and dates concluded.
– Preparation meeting with yard, August 2016
– Pre-fabrication
• Keppel, Platforms, foundations and steel piping
• Harris Pye selected by Owners to supply GRE piping.
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
• Installation and Commissioning
– Yard Schedule – Total 64 days!
• <Provalys> Arrived Keppel September 10th.
• Other repairs / Maintenance
– Expected abt 20 days for Installation and
Commissioning of OceanSaver Equipment and
related piping, electrical installations and
platform / structual modifications.
• OceanSaver are/will be at site for the full
installation period.
• Dry-docking to be Completed Mid
November.
Actual OceanSaver Project time – 1500 hrs
Sister vessel «Gaselys» – Estimated 900 hrs
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
KEY ASPECTS & CHALLENGES
DESIGN PHASE
Proper documentation of onboard systems
«Provalys» pipe Spec GRE/GRP and Drawings
Proper planning of area to be scanned for 3D modelling
Removal of tank top deck plates etc
Importance of Engineering partners knowledge/experience with «OS-BWTS technology»
Location of main equipment, Main filters and C2E Disinfectant skid.
Materials / Installation method in mind
Time frame of project
‘Design changes / Late changes’ from the owner
C2E Location change + 3Dscanning.
Pipe spec changes, Carbon Steel / GRE / GRP
Drains to grey water tank – Bilge tank – Tank re-coating due to Class comment?
Dedicated Project team members (Owner/OS/Engineering partner)
Quality of deliverables after detail engineering (Tie-in point drawings)
Involvement of class at an early stage
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
OceanSaver – Retrofit Project “Provalys” LNGc
KEY ASPECTS & CHALLENGES
INSTALLATION PHASE
Early contact with shipyard
Kick off meeting
Material Handling / Installation methodology – (C2E unit, Filters, etc)
Long lead items for shipyard / Installation (GRE, PE lined pipes) and meeting
the agreed delivery schedules.
OceanSaver recommendation - Ballast tank cleaning & paint touch up
Electrical supervision / Installation
OceanSaver Supervision
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
General terms
REPAYMENT
PERIOD
• Generally: up to
8½ years
• Ships: 2 – 12
years
LOAN AMOUNT
• Capital goods: up to 85% of contract value
• Ship financing: up to
80% of contract value
NORWEGIAN
CONTENT
• Must account for
at least 30% of
the contract
amount
OECD
• All loans must
comply with the
OECD
Arrangement
23OceanSaver – Financing option through Norwegian Export Credit
Confidential – This document is for the use of the intended recipient only and should not be copied or distributed to any other person
Thank you for your attention!
www.oceansaver.com
- The Premier Supplier of BWT Expertise -