Medium:Compressed air only Maximum operating pressure:17 bar (246 psi)Pressure range:0,3 ... 10 bar (4 ... 145 psi) Other pressure ranges areavailable contact NorgrenFilter element:5 or 40 µm
Port sizes:1/4”, 3/8”, 1/2” or 3/4”Gauge port:1/8 PTF with PTF main portsRc1/8 with ISO G main portsDrain:Manual (standard) Optional: automatic
Relieving:WithBowl size:0,2 litre (7 fluid oz)Ambient/Media temperature:-40° ... +80°C (-40° ... +176°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).
Materials:Body and yoke: Zinc alloyConnection piece: Aluminium Metal bowl: Aluminium Prismatic liquid level indicator: Grilamid Filter element: Sintered plastic Adjusting knob: Acetal resin Elastomers: Synthetic rubberw
Technical features
> Port size: 1/4” ... 3/4” (ISO G/PTF)
> High efficiency water removal
> Diaphragm and balanced valve design ensure good regulation characteristics
> Non-rising adjusting knob has snap-action lock
> Quick release bayonet bowl
> Wide temperature range
> Shock and vibration tested to EN 61373, Category 1, class A and B
EN 61373
+80°C (+176°F)
-40°C (-40°F)
Technical data - standard modelsSymbol Port size Size Flow*
dm3/s scfmFilter element(µm)
Weight(kg) (lbs)
ModelISO G thread PTF thread
1/4" — 30 64 40 1,71 3.76 LB64G-2GK-MD3-RMN LB64G-2AK-MD3-RMN
3/8" — 76 161 40 1,69 3.72 LB64G-3GK-MD3-RMN LB64G-3AK-MD3-RMN
1/2" Basic 106 225 40 1,66 3.65 LB64G-4GK-MD3-RMN LB64G-4AK-MD3-RMN
3/4" — 106 225 40 2,02 4.45 LB64G-6GK-MD3-RMN LB64G-6AK-MD3-RMN
Without yoke — 40 LB64G-NNK-MD3-RMN LB64G-NNK-MD3-RMN
1/4" — 30 64 5 1,71 3.76 LB64G-2GK-MD1-RMN LB64G-2AK-MD1-RMN
3/8" — 76 161 5 1,69 3.72 LB64G-3GK-MD1-RMN LB64G-3AK-MD1-RMN
1/2" Basic 106 225 5 1,66 3.65 LB64G-4GK-MD1-RMN LB64G-4AK-MD1-RMN
3/4" — 106 225 5 2,02 4.45 LB64G-6GK-MD1-RMN LB64G-6AK-MD1-RMN
Without yoke — 5 LB64G-NNK-MD1-RMN LB64G-NNK-MD1-RMN
* Typical flow at 10 bar (145 psi) inlet pressure 6,3 bar (90 psi) set, 40 µm element and 1 bar (15 psi) pressure drop.
LB64G-˙˙K-˙˙˙-RMNOption selectorPort size Substitute
1/4“ 2
3/8” 3
1/2” 4
3/4” 6
Without yoke N
Threads form Substitute
PTF A
ISO G parallel (standard) G
Without yoke N
Filter element Substitute
5 µm 1
40 µm 3
Bowl Substitute
With sight glass (standard) D
Without sight glass M
Drain Substitute
Automatic A *1)
Manual, spindle type (standard)
M
*1 ) For temperature range -25 ... 80°C only, shock and vibration, contact Norgren
LB64G - Olympian Plus plug-in system Filter/regulator
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8079d) © 2015 IMI International s.r.o.RW/en 8.240.300.02
7/18
4
3
5
6
8
2
1
Accessories, service kit and gauges
Flow characteristicsInlet pressure: 10 bar, port size: 1/2”, filter element: 40 µm Range: 0,3 ... 10 bar
Regulating characteristicsPort size: 1/2”
Air flow Inlet pressure
Out
let
pre
ssur
e
Out
let
pre
ssur
e
2,9 l / s
29,3 l / s 58,6 l / s
2,3 l / s
46,8 l / s 23,4 l / s
1,5 l / s
15,4 l / s10,2 l / s
1 l / s
0,7 l / s
7,1 l / s
30,8 l / s
20,4 l / s
00
bar
14,2 l / s
2 4 6 8 10 12 14
1
2
3
4
5
6
7
8
9
0 20 40 60 80 100 dm3/s
0 40 80 120 160 200 240 scfm
8
6
4
2
0
bar
100
80
60
40
20
0
psi
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8079d) © 2015 IMI International s.r.o.
LB64G - Olympian Plus plug-in system Filter/regulator
RW/en 8.240.300.037/18
Service kitService kit, manual drain Service kit, automatic drain
LB64G-KITM05R (5 µm) LB64G-KITA05R (5 µm)
LB64G-KITM40R (40 µm) LB64G-KITA40R (40 µm)
Accessories
Thread
Models with G-threadSingle yoke
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Double yokeEnd connector kit
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Rear entry bracket kit
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
G1/4 Y64A-2GA-N1N Y64A-2GA-N2N — —
G3/8 Y64A-3GA-N1N Y64A-3GA-N2N — —
G1/2 Y64A-4GA-N1N Y64A-4GA-N2N 74505-50 —
G3/4 Y64A-6GA-N1N* Y64A-6GA-N2N* 74505-53 18-026-981
1/4 PTF Y64A-2AA-N1N Y64A-2AA-N2N — —
3/8 PTF Y64A-3AA-N1N Y64A-3AA-N2N — —
1/2 PTF Y64A-4AA-N1N Y64A-4AA-N2N 74505-52 —
3/4 PTF Y64A-6AA-N1N* Y64A-6AA-N2N* 74505-55 —
*These yokes are supplied with two end connenctor kits as standard.
Bracket mounting
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Nut
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Tamper resistant cap & seal wire
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Yoke connector kit
74504-50 74502-89 4355-51 74503-51
GaugesCenter back connection, white face (full technical specification see datasheet 8.900.900)
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Pressure range bar *1 MPa psi Ø Thread size Model
0 ... 10 0 ... 1 0 ... 145 50 mm R1/8 18-015-013
*1) primary scale
Center back connection, black face for North America (full technical specification see datasheet 8.900.900)
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Pressure range psig *1 bar MPa Ø Thread size Model
0 ... 160 0 ... 11 0 ... 1.1 1.5” (40 mm) 1/8 NPT 18-015-212
*1) primary scale
LB64G - Olympian Plus plug-in system Filter/regulator
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8079d) © 2015 IMI International s.r.o.RW/en 8.240.300.04
7/18
Basic dimensions
143
114
8,2
85
2,8
14,5
93
30,5
110
48
2
223
194
85
48
2
2,8
110
93
30,5
8,2
14,5 57 80
Single yoke with bracket mounting
Double yoke with bracket mounting
Rear entry bracket 18-026-981
AA
A-A
54,5
83,5
7,5
2
41,5
20,5
8
G 3
/4
29,5
35,8 50 68,5
+0,2
1
1 ‘O’-ring (included in scope of supply of bracket)
Dimensions in mm Projection/First angle
# Minimum clearance required to remove bowl 1 Main ports 1/4”, 3/8”, 1/2” or 3/4” 3 For main ports 3/4” only 4 Sight glass 5 Reduces by 4 mm with knob in locked position 6 Automatic drain (optional)7 Gauge port 1/8”
WarningThese products are intended for use in industrial compressed air and rail transport systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.
The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.
Diese Produkte sind ausschließlich in Druckluft- und Bahnindustrie- systemen zu verwenden. Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-Daten« aufgeführten Werte nicht überschritten werden. Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenserhaltenden- oder anderen Systemen, die nicht in den veröffent-lichten Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an IMI NORGREN.Durch Missbrauch, Verschleiß oder Störungen können in Pneumatik-
systemen verwendete Komponenten auf verschiedene Arten versagen.Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berück-sichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um Verletzungen von Personen sowie Beschädigungen der Geräte im Falle einer solchen Störung zu verhindern. Systemausleger sind verpflichtet, Sicherheitshinweise für den End-benutzer im Betriebshandbuch zu vermerken, wenn der Störungs-schutz nicht ausreichend gewährleistet ist.
ø 47
310
#
169
37
45
125
5
1/8”
11
18,5
6
105
5874
15
157
ø33
3
3
11
4
5 or 3/16”7