Гидра зеркала официальная...
TRANSCRIPT
Superior Quality to
Maximize Efficiency
BRACO ELECTRICALS (INDIA) PVT. LTD.
Maximum achieved with fittings
efficiencyaccurate
Braco overload
products are also designed to take
www.bracoworldwide.comWe manufacture finest quality cable
glands and terminals that are designed
to meet customer requirements. We
understand that quality is very important
in an electrical system. Our products
undergo stringent quality inspections, at
various stages in order to maintain the
required quality standards. We believe
in delivering superior products and
unparallel service at competitive prices.
Our cable glands and terminals are
widely used in the field of power
generation & distribution. Braco
products are used in control panels,
switch gears, transformers, circuit
breakers and various other applications.
Braco Electricals (India) Pvt. Ltd. is
committed to timely deliveries that help
clients complete their respective
projects, on time.
At Braco, we always strive to make
products that are highly efficient in
keeping wastages to a bare minimum.
PROFILE
The year 1977 saw the emergence of Braco products in the Indian Electrical
Market. For the first time, Braco products started the manufacture of cable
glands, under the supervision and guidance of talented and qualified
electrical engineer Shri Ramesh Sobhani.
Braco brand fired up the imagination of top class purchaser of electrical
products like Elecon Engineering Company Limited, who became our first
patron.
Braco products gained reputation and acquired the position of a market
leader in the field of manufacturing and designing of Cable Glands. The
products were in par with international standards. These Cable Glands were
made in all sizes, specifications and designs such as Single Compression
type, SIBG type, Double Compression type, Weather Proof & Flame Proof,
Flange type etc., using materials such as brass for industrial use, aluminum
and stainless-steel for under water cabling.
Due to emergence of grey market in this field, Braco Electricals acquired the
Braco brand under license for its exports and launched the manufacture of
Terminals, Connectors
and other related accessories which created tremendous demand in the
overseas market and thereby it became a major exporter of terminals and
connectors.
Today, Braco is renowned for its superior quality products that minimize
wastage and maximize efficiency.
OUR MISSION
Braco Electricals (India)Pvt.Ltd. will be the preferred choice for providing
knowledge based quality solutions through pioneering efforts to meet
changing market demands and exceed customers expectations .
Braco Electricals (India) Pvt. Ltd. pioneering position has been strengthened by its unique ability to thrive in
a business environments where technologies are changing with lightening speed on account of intelligent
planning and able technocrats.
While every effort has been taken to ensure that the information as contained & printed in this Catalogue is
correct, yet the company will not accept or cannot be held legally responsible for any claims whatsoever for
any inaccuracy, error or omission which might have crept inadvertantly.
In view of the fast technological improvements in our product the company reserve its right to modify any
part of our product as described in this Catalogue.
At Braco
At Braco Pioneering Means Global Recognisation
At Braco Pioneering Means Sustend Growth.
At Braco Pioneering Means Sastisfied Customer
At Braco Pioneering Means Motivated Bracovites
At Braco Pioneering Means Leaveraging Knowledge
At Braco Pioneering Means Wealth Creation
Pioneering Means Market Leader
Brass: An alloy metal comprising 70% Copper and 30% Zinc. Excellent
cold forming property.
Aluminium: Low in weight. Strong in relation to its weight. Good
conductivity, around 60% of that of copper.
Easy to work.
Copper: High conductivity. High corrosion resistance. Good deformation
properties. Good jointing abilit.
FIELD OF APPLICATION
• Control panels, Switchgears, Transformers, Circuit breakers
• Electricity power generation and Distribution Industries
• Electronic Industries
• Railways
• Steel & Fertilizers Industries • Cement & Textile Industries
• Mining Industries
• Sugar Industries
• Defense Industries
• Shipping Industries
• Aeronautic Industries
• Satellite & Communication
Industries
• Automobile Industries
• Chemical Projects
• Domestics
Braco products are used in
INDEX
AT Aluminium Crimping Terminals
AT-XL
ILA
WPA
ATB
BTZ
GS
BC
BPW
FL
CW
BW
A2
Aluminium Tube Terminals For Al-xlpe Conductors
Aluminium Crimping Connector
Aluminium Crimping Reducer Terminals For Aluminium Conductor
Long Barrel Aluminium Crimping Terminals For Aluminium Conductor
Aluminium Alloy Tubular Bimetallic Terminals
Corrosion Inhabiting Compound
onGland Selecti Chart
Single Compression Glands( Commercial Series )
Double Compression Glands( Weather Proof )
Flange Type Cable Glands
BW Type Glands
CW Type Glands
A2 Type Glands
Earth TagsET
PVC Shrouds
Kits
Tailor Made
AT
ATT
PVC
KITS
TM
PAGE NO. PRODUCT SERIES TITLE
Double Hole Aluminium Crimping Terminals For Aluminium Conductors
PAGE NO. PRODUCT SERIES TITLE
SIBG
BPFW
Single Compression Glands( SIBG Series )
E1W E1W Type Glands
Double Compression Glands( Flame Proof )
R, RI, RD
P, PI, PD
F, FI, FD
RF, RFI, RFD
OC
BSS
WB
Copper Crimping Reducer Terminals for Aluminium Conductor
CT
CA
CT
CT
CT
ILC
ILCI
WPC
BMT
BMP
Copper Crimping Terminals With Inspected Hole (light duty)
Copper Crimping Terminals With Inspected Hole For Copper Conductor (heavy duty)
Extended Palm Blanks Copper Crimping Terminals Ends For Copper Conductors
Copper Crimping Terminals For Copper Conductors (long barrel)
Copper Tube In-line Connectors
Copper Tube In-line Connector -Insulated
Bi-Metallic Terminals
Bi-Metallic Pin Terminals
Copper Crimping Ring Terminals (non-insulated and insulated)
Copper Ring Tongue Fork Terminals
Copper Crimping Pin Terminals (non-insulated and insulated)
Copper Crimping Fork Terminals (non-insulated and insulated)
Open Close Soldering Type Copper Ring Terminals
ESCopper Crimping End Sealing Ferrules
Copper Crimping End Sealing Insulated Ferrules
CTSSoldering Type Copper Terminals (light duty)
Soldering Type Copper Terminals (heavy duty)
Soldering Type Copper Weak Back Ferrules
SNP Snap on Terminals
Copper Crimping Terminals For Aluminium Conductor (light duty)
PAGE NO. PRODUCT SERIES TITLE
ESI
PAGE NO. PRODUCT SERIES TITLE
CTCopper Crimping Terminals DIN 46235
Cable Glands and Terminals COPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALS
2.5
4-6
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.3
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
4.3
4.3
3.2
3.7
3.7
4.2
5.2
5.2
6.4
5.2
6.4
8.2
6.4
8.2
10.2
10.2
12.7
4.2
5.2
4.2
5.2
5.2
5.2
6.4
8.2
5.2
6.4
6.4
8.2
9.7
8.2
10.2
8.2
10.2
12.7
4.2
8.2
12.7
12.7
16.0
16.0
16.0
18.0
18.0
22.0
22.0
22.0
25.0
25.0
25.0
29.0
29.0
17.0
17.0
19.0
19.0
22.0
20.0
20.0
20.0
22.0
22.0
25.5
25.5
25.5
30.0
30.0
30.0
30.0
30.0
22.0
22.0
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
16
16
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
3.9
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
6.3
6.3
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
4.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.4
6.8
6.8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
17
17
6.5
6.5
8.0
8.0
8.0
10.0
10.0
12.0
12.0
12.0
16.0
16.0
16.0
18.0
18.0
8.0
8.0
10.0
10.0
8.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
16.0
16.0
18.0
18.0
18.0
10.0
18.0
R - 107
R - 008
R - 108
R - 009
R - 010
R - 109
R - 011
R - 110
R - 012
R - 013
R - 111
R - 014
R - 015
R - 151
R - 047
R - 155
R - 050
R - 112
R - 016
R - 157
R - 113
R - 017
R - 018
R - 114
R - 019
R - 115
R - 020
R - 021
R - 116
R - 022
R - 117
R - 023
R - 024
R - 118
R - 025
RI - 068
RI - 069
RI - 070
RI - 071
RI - 072
RI - 073
RI - 074
RI - 075
RI - 076
RI - 077
RI - 078
RI - 079
RI - 080
RI - 081
RI - 082
RI - 083
RI - 084
RI - 085
RI - 086
RI - 087
RI - 088
RI - 089
RI - 090
RI - 091
RI - 092
RI - 093
RI - 094
RI - 095
RI - 096
RI - 097
RI - 098
RI - 099
RI - 100
RI - 389
RI - 395
RD - 451
RD - 452
RD - 453
RD - 454
RD - 455
RD - 456
RD - 457
RD - 458
RD - 459
RD - 460
RD - 461
RD - 462
RD - 463
RD - 464
RD - 465
RD - 466
RD - 467
RD - 468
RD - 469
RD - 470
RD - 471
RD - 472
RD - 473
RD - 474
RD - 475
RD - 476
RD - 477
RD - 478
RD - 479
RD - 480
RD - 481
RD - 482
RD - 483
RD - 484
RD - 485
SizeSq. mm
Code No. Code No. Code No.Dimensions
BAE JCA-1 J-1J-1
D
Wire barrel
Bell mouthed for easy cable entry
Colour coded bell mouthed PVC insulation
Bell mouthed copper sleeve
High conductivity copper tinned for
corrosion resistance
Bell mouthed chamfered lead-in
Braco Ring Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanicals vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction. All the terminals are tin plated to avoid oxidization and to achieve maximum corrosion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.
1.5 2.5 4.6
Colour Coding Insulated Terminals:
1.5 1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.2
2.6
3.2
3.7
4.2
3.2
3.7
4.2
3.2
4.2
5.2
4.2
4.2
5.2
6.4
6.4
14.0
14.0
14.0
14.0
14.0
13.0
13.0
13.0
16.0
16.0
16.0
14.5
18.0
18.0
18.0
18.0
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
6.0
6.0
6.0
6.0
6.0
6.8
6.8
6.8
8.0
8.0
8.0
7.0
10.0
10.0
10.0
12.0
R - 103
R - 000
R - 001
R - 002
R - 003
R - 153
R - 048
R - 049
R - 104
R - 004
R - 005
R - 154
R - 105
R - 006
R - 007
R - 106
RI - 052
RI - 053
RI - 054
RI - 055
RI - 056
RI - 057
RI - 058
RI - 059
RI - 060
RI - 061
RI - 062
RI - 063
RI - 064
RI - 065
RI - 066
RI - 067
RD - 435
RD - 436
RD - 437
RD - 438
RD - 439
RD - 440
RD - 441
RD - 442
RD - 443
RD - 444
RD - 445
RD - 446
RD - 447
RD - 448
RD - 449
RD - 450
SizeSq. mm
Code No. Code No. Code No.Dimensions
AE JC A-1 J-1J-1D
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
B
Material Copper BS: 1897 Finish: Electro Tinned
COPPER CRIMPING RING TERMINALS (NON-INSULATED AND INSULATED)
D
J1C
E
B
J
AJ
CA
B
D
E
SizeSq. mm Code No.
Dimensions
DE BA JC
35
50
70
95
120
150
6.4
8.2
8.2
10.2
10.2
12.7
8.2
10.2
10.2
10.2
12.7
16.2
10.2
12.7
12.7
16.2
10.2
10.2
12.7
16.2
12.7
16.2
20.3
12.7
16.2
20.3
9.0
9.0
9.0
9.0
9.0
9.0
10.5
10.5
10.5
10.5
10.5
10.5
12.0
12.0
12.0
12.0
13.5
13.5
13.5
13.5
15.0
15.0
15.0
16.5
16.5
16.5
12.6
12.6
12.6
12.6
12.6
12.6
14.1
14.1
14.1
14.1
14.1
14.1
16.0
16.0
16.0
16.0
18.1
18.1
18.1
18.1
20.2
20.2
20.2
23.7
23.7
23.7
16
16
18
18
22
22
18
18
22
24
24
32
22
22
24
24
22
24
24
28
26
32
40
34
34
40
12
12
12
12
12
12
16
16
16
16
16
16
18
18
18
20
20
20
20
20
22
22
22
24
24
24
31
31
36
36
42
42
43
43
43
48
48
54
47
47
48
54
46
50
50
58
52
64
72
66
66
74
R - 133
R - 038
R - 134
R - 039
R - 135
R - 040
R - 136
R - 041
R - 137
R - 138
R - 042
R - 139
R - 140
R - 043
R - 141
R - 142
R - 143
R - 144
R - 044
R - 145
R - 146
R - 147
R - 148
R - 149
R - 045
R - 046
COPPER CRIMPING RING TERMINALS (NON-INSULATED)
SizeSq. mm Code No.
Dimensions
DE BA JC
10
16
10
12
16
18
18
22
22
10
12
12
16
16
16
18
18
22
22
12
12
16
16
16
16
16
18
22
22
5.2
6.4
8.2
8.2
10.2
10.2
12.7
5.2
5.2
6.4
6.4
8.2
9.7
8.2
10.2
10.2
12.7
6.4
8.2
6.4
8.2
10.2
6.4
8.2
10.2
10.2
12.7
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
11
11
4.3
4.3
4.3
4.3
4.3
4.3
4.3
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
20
23
27
30
30
34
34
24
26
26
30
30
30
33
33
35
35
31
31
30
30
30
33
33
34
42
42
6.3
6.3
6.3
6.3
6.3
6.3
6.3
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
11.1
11.1
11.1
11.1
11.1
11.1
11.1
11.1
11.1
11.1
R - 026
R - 120
R - 121
R - 122
R - 027
R - 123
R - 028
R - 124
R - 125
R - 029
R - 126
R - 030
R - 031
R - 127
R - 032
R - 128
R - 033
R - 156
R - 051
R - 129
R - 034
R - 035
R - 130
R - 036
R - 131
R - 132
R - 037
25
Braco Ring Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanicals vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction. All the terminals are tin plated to avoid oxidization and to achieve maximum corrosion protection.
JC
A
B
D
E
Braco Ring Tongue Fork Terminals are designed to offer maximum efficiency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanical vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction.All the terminals are tin plated to avoid oxidisation and to achieve maximum corrossion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.
Material Copper BS: 1897 Finish: Electro Tinned
1.5 2.5 4.6
Colour Coding Insulated Terminals:
COPPER RING TONGUE FORK TERMINALS
J
1.5
2.5
4-6
10
16
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
8
8
8
8
10
10
10
10
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.3
2.3
2.3
2.3
2.3
3.5
3.5
3.5
3.5
3.5
4.3
4.3
4.3
4.3
5.6
5.6
5.6
5.6
3.1
3.6
3.1
3.6
4.1
4.1
5.1
6.1
3.1
3.6
4.1
5.1
6.1
4.1
4.1
5.1
5.1
6.1
4.1
5.1
6.1
8.1
5.1
6.1
8.1
8.1
14
14
13
13
14
16
18
18
12.7
12.7
16
18
18
17
19
19
22
22
22
22
23
27
24
26
30
33
10
10
10
10
10
10
10
10
10
10
10
10
10
14
14
14
14
14
16
16
16
16
--
--
--
--
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.9
3.9
3.9
3.9
3.9
5.5
5.5
5.5
5.5
5.5
6.3
6.3
6.3
6.3
8.0
8.0
8.0
8.0
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
4.4
4.4
4.4
4.4
4.4
6.4
6.4
6.4
6.4
6.4
6.8
6.8
6.8
6.8
--
--
--
--
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
17
17
17
17
--
--
--
--
6.0
6.0
6.8
6.8
7.0
8.0
10.0
10.0
6.5
6.5
8.0
10.0
10.0
8.0
10.0
10.0
10.0
12.0
10.0
10.0
12.0
16.0
10.0
12.0
16.0
18.0
RF - 235
RF - 240
RF - 241
RF - 244
RF - 237
RF - 236
RF - 238
RF - 861
RF - 862
RF - 863
RF - 239
RF - 242
RF - 864
RF - 243
RF - 245
RF - 246
RF - 247
RF - 248
RF - 865
RF - 866
RF - 867
RF - 868
RF - 869
RF - 870
RF - 871
RF - 872
RFI - 873
RFI - 874
RFI - 875
RFI - 876
RFI - 877
RFI - 878
RFI - 879
RFI - 880
RFI - 881
RFI - 882
RFI - 883
RFI - 884
RFI - 885
RFI - 886
RFI - 887
RFI - 888
RFI - 889
RFI - 890
RFI - 891
RFI - 892
RFI - 893
RFI - 894
-----
-----
-----
-----
RFD - 899
RFD - 900
RFD - 901
RFD - 902
RFD - 903
RFD - 904
RFD - 905
RFD - 906
RFD - 907
RFD - 908
RFD - 909
RFD - 910
RFD - 911
RFD - 912
RFD - 913
RFD - 914
RFD - 915
RFD - 916
RFD - 917
RFD - 918
RFD - 919
RFD - 920
-----
-----
-----
-----
SizeSq. mm AE BC D
Dimensions
J
Code No. Dim.
J-1
Code No.Dimensions
A-1 J-1
Code No.
DE J
B
AC
J1
Braco Pin Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanical vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction
All the terminals are tin plated to avoid oxidisation and to achieve maximum corrossion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.
COPPER CRIMPING PIN TERMINALS (NON-INSULATED AND INSULATED)
SizeSq. mm
Code No. Code No. Code No.Dimensions
BA TYPEJC A-1 J-1J-1D
1.5
2.5
4
6
10
16
25
35
50
70
95
5
5
5
5
6
6
6
6
8
10
11
12
16
18
21
1.6
1.6
2.3
2.3
2.9
3.6
3.6
4.0
4.5
5.8
7.5
9.0
10.5
12.0
13.8
I
II
I
II
I
II
I
I
III
III
III
III
III
III
III
17
17
17
17
20
20
20
20
22
26
31
37
42
45
52
10
10
10
10
14
14
14
14
16
20
3.2
3.2
3.9
3.9
4.9
5.6
5.6
6.0
6.7
8.2
11.1
12.6
14.1
16.0
18.7
3.6
3.6
4.4
4.4
6.4
6.4
6.4
6.4
10
10
10
10
15
15
15
15
1.9
3.1
1.9
3.1
2.7
5.1
2.7
2.7
4.3
5.5
7.0
8.0
9.0
10.0
11.0
P - 9
P - 35
P - 1
P - 2
P - 3
P - 4
P - 5
P - 6
P - 7
P - 8
P - 86
P - 87
P - 88
P - 94
P - 95
PI - 17
PI - 40
PI - 18
PI - 19
PI - 20
PI - 21
PI - 22
PI - 23
PI - 24
PI - 25
PD - 26
PD - 42
PD - 27
PD - 28
PD - 29
PD - 30
PD - 31
PD - 32
Material Copper BS :1897Finish : Electro Tinned
1.5 2.5 4.6
Colour Coding Insulated Terminals:
D
J1
D
J1
B
J
CA
BJ
CA
Braco Fork Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanical vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed which means that the terminal can be crimped in either directionAll the terminals are tin plated to avoid oxidisation and to achieve maximum corrossion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.
Material Copper BS: 1897 Finish: Electro Tinned
1.5 2.5 4.6
Colour Coding Insulated Terminals:
COPPER CRIMPING FORK TERMINALS (NON-INSULATED AND INSULATED)
SizeSq. mm
Code No. Code No. Code No.Dimensions
DE JBA A-1 J-1J-1C
1.5
2.5
4-6
10
5
4
5
5
6.2
6
6
8
8
1.6
1.6
2.0
2.3
2.6
3.5
3.5
4.5
4.5
5.1
3.5
3.0
3.5
5.0
3.1
3.5
6.5
8.2
21
13
13
15
21
15
15
27
27
10
10
10
10
10
14
14
16
16
3.2
3.2
2.8
3.9
4.6
5.5
5.5
6.9
6.9
3.6
3.6
3.6
4.4
4.4
6.4
6.4
6.8
6.8
10
10
10
10
10
15
15
17
17
8.0
6.8
6.2
6.5
10.6
6.0
6.0
16.0
16.0
F - 214
F - 249
F - 250
F - 251
F - 280
F - 252
F - 253
F - 254
F - 255
FI - 925
FI - 926
FI - 927
FI - 928
FI - 929
FI - 930
FI - 931
FI - 932
FI - 933
FD - 934
FD - 935
FD - 936
FD - 937
FD - 938
FD - 939
FD - 940
FD - 941
FD - 942
D
C
J
Braco open close terminals are made out of EC grade copper. These terminals ensure completeness and ease of conductor entry so that contact is reliable and have more tensile strength. The terminals are annealed to avoid cracking or breaks and are tin plated to avoid oxidization and to achieve maximum corrossion protection.
Material Copper BS :1897Finish : Electro Tinned
SizeSq. mm
Code No.Dimensions
DE BA JC
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
225
240
300
400
500
625
7
9
9
12
12
15
15
18
24
28
32
34
38
42
44
48
54
62
62
70
4.2
5.2
5.2
6.5
6.5
8.2
8.2
8.2
10.2
10.2
12.7
12.7
12.7
16.2
16.2
16.2
20.3
20.3
20.3
20.3
5
6
6
7
9
11
14
15
18
23
25
29
30
35
40
42
45
54
58
65
1.6
2.3
2.8
3.6
4.4
5.4
7.0
8.0
9.5
11.8
13.5
15.5
16.5
18.5
21.0
22.5
25.0
29.5
32.0
36.0
15
18
20
24
27
32
36
41
50
58
66
73
79
87
92
100
110
125
137
148
3.2
3.9
4.8
5.6
6.4
7.8
10.2
11.2
13.1
15.8
18.7
21.1
22.9
25.7
28.2
30.5
34.0
39.5
42.8
46.8
OC - 71
OC - 72
OC - 73
OC - 74
OC - 75
OC - 76
OC - 77
OC - 78
OC - 79
OC - 80
OC - 81
OC - 82
OC - 83
OC - 84
OC - 85
OC - 86
OC - 87
OC - 88
OC - 89
OC - 90
OPEN CLOSE SOLDERING TYPE COPPER RING TERMINALS
D
EB
J
AC
BJ1
E
A
Braco End Sealing Ferrules are manufactured from electrolytic copper. These ferrules are used when a perfect connection is needed at the end of a cable. Some cables, especially those with small diameters, may conduct badly in electrical connections without an End Sealing Ferrule. By using these ferrules strands deviation can be avoided and the risk of cable breakage can be reduced. Also these ferrules create a long lasting contact pressure and a large contact surface. Tinning is provided to give better finish, to avoid oxidisation and to achieve maximum corrosion protection.
Material Copper BS: 1997 Finish: Electro Tinned
SizeSq. mm
Code No.Dimensions
A C J
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10
16
1.0-1.1
1.4-1.5
1.6-1.7
1.6-1.7
1.8-1.9
1.8-1.9
2.3-2.4
2.3-2.4
2.8-2.9
2.8-2.9
3.7-3.8
3.7-3.8
3.7-3.8
4.6-4.7
4.6-4.7
4.6-4.7
5.9-6.0
5.9-6.0
5.9-6.0
1.4-1.5
1.8-1.9
2.0-2.1
2.0-2.1
2.2-2.3
2.2-2.3
2.7-2.8
2.7-2.8
3.2-3.3
3.2-3.3
4.1-4.2
4.1-4.2
4.1-4.2
5.0-5.1
5.0-5.1
5.0-5.1
6.3-6.4
6.3-6.4
6.3-6.4
6
6
6
10
7
10
7
12
9
12
10
12
15
12
15
18
12
15
18
ES - 08
ES - 09
ES - 10
ES - 11
ES - 12
ES - 13
ES - 14
ES - 15
ES - 16
ES - 17
ES - 18
ES - 19
ES - 20
ES - 21
ES - 22
ES - 23
ES - 24
ES - 25
ES - 26
COPPER CRIMPING END SEALING FERRULES
J
CA
Braco End Sealing Insulated Ferrules are manufactured from electrolytic copper. These ferrules have dimensions according to DIN 46228 and are used when a perfect connection is needed at the end of a cable. Some cables, especially those with small diameters, may conduct badly in electrical connections without an End Sealing Ferrule. By using these ferrules strands deviation can be avoided and the risk of cable breakage can be reduced. Also these ferrules create a long lasting contact pressure and a large contact surface. Tinning is provided to give better finish, to avoid oxidisation and to achieve maximum corrosion protection.
The Insulation Sleeve is manufactured from PP (Polypropylene). We also offer end terminals with insulation colours according to the most common colour system in the market. The colour of the insulation sleeves characterises the Cross section area of the conductor
Material Copper BS :1997Finish : Electro Tinned
COPPER CRIMPING END SEALING INSULATED FERRULES
SizeSq. mm
Code No.Dimensions
A C J
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10
16
1.0-1.1
1.4-1.5
1.6-1.7
1.6-1.7
1.8-1.9
1.8-1.9
2.3-2.4
2.3-2.4
2.8-2.9
2.8-2.9
3.7-3.8
3.7-3.8
3.7-3.8
4.6-4.7
4.6-4.7
4.6-4.7
5.9-6.0
5.9-6.0
5.9-6.0
1.4-1.5
1.8-1.9
2.0-2.1
2.0-2.1
2.2-2.3
2.2-2.3
2.7-2.8
2.7-2.8
3.2-3.3
3.2-3.3
4.1-4.2
4.1-4.2
4.1-4.2
5.0-5.1
5.0-5.1
5.0-5.1
6.3-6.4
6.3-6.4
6.3-6.4
6
6
6
10
7
10
7
12
9
12
10
12
15
12
15
18
12
15
18
ESI - 08
ESI - 09
ESI - 10
ESI- 11
ESI- 12
ESI- 13
ESI - 14
ESI- 15
ESI- 16
ESI- 17
ESI- 18
ESI- 19
ESI- 20
ESI- 21
ESI- 22
ESI- 23
ESI - 24
ESI - 25
ESI- 26
J-1
12
12
12
16
14
16
14
18
16
18
18
20
23
22
25
28
24
27
30
JA
J1
C
Braco snap on Terminals are made out of Phosporus bronze These are used in electrical and electronic installations like PCB mounted devices, electronic power relays etc. These can also be provided with insulation.
SNAP ON TERMINALS
0.7
0.25
2
6
71.
B B
15
4
Section on A-A
Section on B-B
2.8
2.5
8368
CAT. NO.
AA
61 9
1.54
1.6.61
17
6
30.
8
8370
CAT. NO.
14
CAT. NO.
8351 8352
CAT. NO.
7.6
16
21
6.6
2.4
3
10
3.62.4Ø
0.4
CAT. NO. CAT. NO.8358 8359
2.6 0.4
4.9
1.1
10
19 2.4
3.6
146.
4
2.4
5.8 6
2
17
1.
2.6
AA
4.2
7.6
15
2.
.7 2
.3 2
23.
04.
8178
CAT. NO.
.67
17
21
01
2.8.50
3.2
.76
.1 6
.82
.44
8347/8348
CAT. NO.
0.8
16
79
21.5
3 4
1
1.5
8369
CAT. NO.
1
7.6
7.6
0 8.
1.6
6.6
16
2.4
2
6.3
2110
3.6
8360/8361
CAT. NO.
515.5
2
103.2
3.2
1.6
8.2
0.9
2.5
73.210
8
24
906.6
5
34
3.
8367
CAT. NO.Sectional Plan
CAT. NO. CAT. NO.8324 8325
142
6.4
2.7Ø
0.25
19
10
3.10.7
3.6Ø
2.4
7.1
0.3
B B
3.1
28.
4
420
31.
8364
CAT. NO.
Section On A-A Section On B-B
7.5
2.3
7.6
163
21
10
.40
6.61.6
1.34.4
8349/8350
CAT. NO.
CAT. NO.
8197
CAT. NO.
8353
0.8
4.9
2.4
14
2.6 0.4
6.4
1910
2.4
4.4
8477
CAT. NO.
3.2
36.
28.
5.5
3Ø
2.5
7
.20
5.
143
4.2
3.2
5.2
6.2
1032
32
.4 4.2 3.2 3
4
.0 8 6.4
8
8363/8473
CAT. NO.
0.84.5
8
8
166.4
.21
4
8
8346
A .C T NO.83318241
CAT. NO. CAT. NO.
19
146.
4
10
23. .0 52
.3 1.0 7 3. Ø6
2.7Ø
CAT. NO.
8362
146
4.
2.7Ø
19
10
2
.0 25
3.10.7
.3 6Ø
CAT. NO.
8336
CAT. NO.
8356 8357
CAT. NO.
13.2 2
0.4.3 6Ø
5.4
18
.0 52
01
2. Ø7
1.5
CAT. NO.
8476
CAT. NO.
2.8
6.4Ø
2.8Ø
21
17
10
7.6
0.5
0.7
6.7
3.2
1.6
8347
8366
CAT. NO.
8474
CAT. NO.
3.5
6.9
1.4
450.
81
2.9
8
44.
21.5
10
29
CAT. NO.
8354
2.7
131
5.
0.25
0.4
2.2
5.4
8110
6Ø3.
CAT. NO.
83558365
CAT. NO. CAT. NO.
8475
18
10.
215
.2 3
.2 3
.35 0.56
1.4
4.4.6 7
8
53.
7
11
3.5
ox 1 453 1
7
2 H LE O S 2.8
- 0
3.2
8
R
70. 8 0 83.
8214
CAT. NO.
SCOPE OF LUGS: The Cable Lugs are used for termination of cables to the equipments and connectors are used to extend the cables. The cable sizes vary as per the electric current requirements. Generally cable sockets/terminals used shall be of E. C. Grade copper. The cable sockets shall be duly tin plated for outer finish and to withstand the corrosion while storage and use.
PROCESS OF MANUFACTURING CABLE LUGS
A) EXTRUSIONS: The cable Lugs & Connectors of various sizes are manufactured out of copper EC Grade wire bars. These wire bars are cut into 3 to 4 parts for melting. These are refined and are casted into round ingots as per required sizes. These ingots under go a process of cutting, which finally turns into the extrusion billets. These billets are drilled as per required I.D. of the internal diameter of tubes. These are further heated in gas fired furnaces to appropriate extrusion temperature. The heated billets are then extruded by hydropneumatic press into the mother tubes of required sizes. Three types of mother tubes are used for copper cable sockets.
B) TUBE DRAW: The copper mother tubes are finally made to required size of copper tubes which varies as per size of cable. The chart show the various sizes of copper tubes used. The dimension 'C' is 0. D. and 'A' is I. D. of Tube required for the particular cable terminals. The process is called tube drawing process. The mother tubes are drawn in draw bench with required T.C. dies of O.D, and plug for required I. D.
During the process the copper undergoes annealing process and each time the tube made to smaller size by swaging machine so that the pipe to be pulled at the beginning of pipe. This swaged pipes are pulled in draw bench every time it passes through small T.C. dies to reduce the diameters and every time these are annealed in heating furnace which gives burning and annealing loss.
PROCESS
C) CABLE LUGS MANUFACTURING: The drawn tubes are finally cut into the pieces in cutting machine to the required length of cable lugs and are chamfered. The cut tubes are finally annealed in annealing furnace and forged to make the plam of socket and in cutting process the front arc and hole is made. The lugs are then marked with required code number and size of cable. After this the lugs are ready for plating.
I.D.
O.D.
50
64
38
50
37.5
40
D) TINNING PROCESS:
The cable lugs are finally acid tinned in plating plant. The tinning process is required for surface finish as well as to avoid corrosion whilst storage and use.
The cable sockets are finally checked and packed in boxes with sizes marked on the box. These boxes are finally packed in master carton for the final dispatch in export worthy packing.
All the process checked at each stage as per the quality assurance plan.
COPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALS
Braco soldering type heavy duty copper terminals are made out of EC grade copper and used where high value of current flow is desired and due to soldering loose terminations are avoided, thereby preventing heating at termination ends. Terminals are tin plated to avoid oxidization and to achieve maximum corrossion protection.
SOLDERING TYPE COPPER TERMINALS (HEAVY DUTY)
AMPS Code No.Dimensions
DE BA JC
15
30
60
100
150
200
300
400
500
300
500
630
9
12
17
21
25
29
36
41
46
49
59
67
5.1
7.1
10.3
11.9
13.5
13.5
16.7
16.7
19.8
18.0
22.0
26.0
10
13
14
19
22
29
32
38
44
44
48
56
4.8
6.4
9.5
11.9
14.3
16.7
20.6
23.8
26.2
26.2
31.7
36.5
24
33
44
55
62
78
86
100
111
111
121
139
6.2
8.0
11.3
13.9
17.1
19.9
24.2
27.8
31.4
34.2
40.9
46.1
BSS - 6
BSS - 7
BSS - 8
BSS - 9
BSS - 10
BSS - 11
BSS - 12
BSS - 13
BSS - 14
BSS - 28
BSS - 29
BSS - 30
Material Copper BS :1977Finish : Electro Tinned
SOLDERING TYPE COPPER TERMINALS (LIGHT DUTY)Braco soldering type copper terminals are made out of EC grade copper and used where high value of current flow is desired and due to soldering loose terminations are avoided, thereby preventing heating at termination ends. Terminals are tin plated to avoid oxidization and to achieve maximum corrossion protection.
AMPS Code No.
Dimensions
DE BA JC
15
30
60
100
150
200
300
400
500
600
800
1000
1000
7
9
14
19
24
28
33
38
43
47
56
66
85
3.9
5.2
8.1
10.9
13.9
16.6
19.0
22.2
25.4
27.8
31.7
38.1
50.0
19
23
36
49
57
66
80
89
105
115
121
152
164
CTS - 01
CTS - 02
CTS - 03
CTS - 04
CTS - 05
CTS - 06
CTS - 07
CTS - 08
CTS - 09
CTS - 10
CTS - 11
CTS - 12
CTS - 95
3.2
5.1
6.4
9.5
9.5
12.7
12.7
15.9
19.0
19.0
23.8
23.8
-
4.8
6.3
9.5
12.7
15.9
19.0
22.2
25.4
28.6
31.8
38.1
44.5
57.3
7
9
14
19
23
27
28
32
38
44
47
56
62
Material Copper BS :1977Finish : Electro Tinned
E
CA
BJ
D
E
CA
BJ
D
Braco Soldering Type Weak Back Ferrules are manufactured out of copper and are used to solder straight through joints. Tinning is provided to give better finish, to avoid oxidisation and to achieve maximum corrossion protection.
6
10
16
25
35
50
70
95
120
150
185
225
240
300
400
500
625
20
25
25
30
35
40
45
50
55
60
65
75
80
85
95
105
115
3
4
5
7
8
9
12
13
15
16
18
20
21
23
27
30
33
WB - 79
WB - 80
WB - 81
WB - 82
WB - 83
WB - 84
WB - 85
WB - 86
WB - 87
WB - 88
WB - 89
WB - 90
WB - 91
WB - 92
WB - 93
WB - 94
WB - 95
SizeSq. mm
Code No.Dimensions
LA TC PG
3.0
4.4
5.5
7.0
8.0
9.5
12.0
13.5
15.5
17.0
18.5
20.5
22.0
24.0
28.5
30.5
34.5
2
2
2
2
2
2
3
3
4
4
4
5
5
5
7
7
8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.8
2.2
2.2
2.2
2.8
3.1
3.5
4.0
4.6
6.0
7.5
9.0
10.4
11.9
14.8
16.3
18.7
20.6
22.9
24.9
26.4
29.6
34.7
37.5
42.5
SOLDERING TYPE COPPER WEAK BACK FERRULES
Material Copper BS :1997Finish : Electro Tinned
P
L
Braco Copper Tube Crimping Terminals are manufactured from electrolytic copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cables, electrical switching equipments, where vibration is critical.
Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In application subject to vibration, terminals still have to perform a reliable connection. Annealing plays a vital role in avoiding cracking or breaks between the barrel and plam. Tin plating on the terminals avoids oxidization and achieves maximum corrossion protection.
COPPER CRIMPING TERMINALS FOR ALUMINIUM CONDUCTOR (LIGHT DUTY)
Material : Copper BS :1977 Finish : Electro Tinned
95
120
150
185
225
240
300
400
500
630
800
1000
23
23
26
26
26
28
28
28
32
32
35
38
38
42
42
49
53
61
67
76
10.2
12.7
10.2
12.7
16.2
10.2
12.7
16.2
12.7
16.2
16.2
16.2
20.3
16.2
20.3
20.3
20.3
20.3
-
-
20
20
22
22
22
26
26
26
30
30
34
36
36
39
39
44
48
55
65
90
12.8
12.8
14.8
14.8
14.8
16.0
16.0
16.0
18.0
18.0
20.0
22.0
22.0
24.0
24.0
28.0
30.0
35.0
39.0
43.0
58
58
62
62
62
70
70
70
83
83
95
97
97
103
103
116
120
137
165
210
15.6
15.6
17.8
17.8
17.8
19.6
19.6
19.6
22.0
22.0
24.0
26.0
26.0
28.7
28.7
33.2
36.0
41.5
46.3
53.8
CT - 19
CT - 20
CT - 21
CT - 22
CT - 23
CT - 24
CT - 25
CT - 26
CT - 27
CT - 28
CT - 231
CT - 29
CT - 30
CT - 31
CT - 32
CT - 33
CT - 34
CT - 35
CT - 62
CT - 76
SizeSq. mm Code No.
Dimensions
DE BA JC
2.5
4
6
10
16
25
35
50
70
9
11
11
11
11
13
15
15
16
16
16
20
20
20
5.2
6.2
6.2
6.2
6.2
6.2
6.2
8.2
6.2
8.2
10.2
8.2
10.2
12.7
7
7
9
9
12
12
12
12
16
16
16
18
18
18
2.0
3.1
3.8
4.4
5.3
7.0
8.0
8.0
9.2
9.2
9.2
11.5
11.5
11.5
20
22
24
24
30
37
37
37
45
45
45
56
56
56
3.7
4.8
5.5
6.2
7.1
9.0
10.0
10.0
11.2
11.2
11.2
13.8
13.8
13.8
CT - 05
CT - 06
CT - 07
CT - 08
CT - 09
CT - 10
CT - 11
CT - 12
CT - 13
CT - 14
CT - 15
CT - 16
CT - 17
CT - 18
P
T G
WL
AC
E
CA
BJ
D
Braco Copper Tube Crimping Terminals With Inspection Hole are manufactured from Electrolytic Copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cables, electrical switching equipments, where vibration is critical.
Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In application subject to vibration, terminals still have to perform a reliable connection, annealing plays a vital role in avoiding cracking or breaks between the barrel and palm.
The presence of inspection hole facilitates full insertion of conductor while the barrel length has been designed to allow easy and accurate posi t ion dies d u r i n g t h e c r i m p i n g operation.
Tin plating on the terminals avoids oxidizat ion and a c h i e v e s m a x i m u m corrosion protection.
COPPER CRIMPING TERMINALS WITH INSPECTION HOLE (LIGHT DUTY)
Material Copper BS :1977Finish : Electro Tinned
SizeSq. mm Code No.
Dimensions
DE BA JC
35
50
70
95
17
17
17
17
20
20
20
20
20
20
20
20
22
22
22
6.4
8.4
10.5
13.6
6.4
8.4
10.5
13.0
6.4
8.4
10.5
13.0
8.4
10.5
13.0
15
15
15
15
16
16
16
16
20
20
20
20
23
23
23
8.0
8.0
8.0
8.0
9.2
9.2
9.2
9.2
11.6
11.6
11.6
11.6
12.8
12.8
12.8
40
40
40
40
49
49
49
49
58
58
58
58
60
60
60
10.0
10.0
10.0
10.0
11.2
11.2
11.2
11.2
13.8
13.8
13.8
13.8
15.6
15.6
15.6
CA - 35 / 6
CA - 35 / 8
CA - 35 / 10
CA - 35 / 12
CA - 50 / 6
CA - 50 / 8
CA - 50 / 10
CA - 50 / 12
CA - 70 / 6
CA - 70 / 8
CA - 70 / 10
CA - 70 / 12
CA - 95 / 8
CA - 95 / 10
CA - 95 / 12
SizeSq. mm Code No.
Dimensions
DE BA JC
120
150
185
240
300
400
500
630
800
1000
25.5
25.5
25.5
25.5
29.0
29.0
29.0
34.5
34.5
34.5
41.0
41.0
41.0
43.5
43.5
47.0
47.0
54.0
54.0
63.0
80.0
100.0
8.4
10.5
13.0
17.0
10.5
13.0
17.0
10.5
13.0
17.0
13.0
17.0
21.0
17.0
21.0
17.0
21.0
17.0
21.0
21.0
--
--
26
26
26
26
28
28
28
32
32
32
38
38
38
42
42
49
49
53
53
61
67
76
14.8
14.8
14.8
14.8
16.0
16.0
16.0
18.0
18.0
18.0
22.0
22.0
22.0
24.0
24.0
28.0
28.0
30.0
30.0
35.0
39.0
43.0
65.5
65.5
65.5
65.5
73
73
73
86.5
86.5
86.5
102
102
102
107
107
119
119
126
126
145
170
205
17.8
17.8
17.8
17.8
19.6
19.6
19.6
22.0
22.0
22.0
26.0
26.0
26.0
28.7
28.7
33.2
33.2
36.0
36.0
41.5
46.3
53.8
CA - 120 / 8
CA - 120 / 10
CA - 120 / 12
CA - 120 / 16
CA - 150 / 10
CA - 150 / 12
CA - 150 / 16
CA - 185 / 10
CA - 185 / 12
CA - 185 / 16
CA - 240 / 12
CA - 240 / 16
CA - 240 / 20
CA - 300 / 16
CA - 300 / 20
CA - 400 / 16
CA - 400 / 20
CA - 500 / 16
CA - 500 / 20
CA - 630 / 20
CA - 800 / BL
CA - 1000 / BL
E
CA
BJ
D
Braco Copper Tube Crimping Terminals are manufactured from Electrolytic Copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cables to terminating electrical switching equipments, where vibration is critical.
Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In applicaion subject to vibration, terminals still have to perform a reliable connection, annealing plays a vital role in avoiding cracking or breaks between the barrel and palm.
The presence of inspection hole facilitates full insertion of conductor while the barrel length has been designed to allow easy and accurate position dies during the crimping operation.
Tin plating on the terminals avoids oxidization and a c h i e v e s m a x i m u m corrossion protection
COPPER CRIMPING TERMINALS WITH INSPECTION HOLE FOR COPPER CONDUCTOR (HEAVY DUTY)
SizeSq. mm Code No.
Dimensions
DE BA JC
16
25
35
50
70
12
12
12
14.5
18
13
16
16
16.5
15.3
15.3
18
17
18
18
18
18
22.0
21.0
21.0
21.0
21.0
25.0
25.0
26.0
5.2
6.4
8.4
10.5
12.7
6.4
8.4
10.5
12.7
6.5
8.4
10.5
12.7
6.5
8.4
10.5
12.7
17.0
6.4
8.4
10.5
13.0
15.0
17.0
21.0
12
12
12
13
13
12
12
12
14
12
12
12
15
16
16
16
16
18
18
18
18
18
20
20
20
5.4
5.4
5.4
5.5
5.5
6.8
6.8
6.8
6.8
8.2
8.2
8.2
8.2
9.5
9.5
9.5
9.5
9.5
11.2
11.2
11.2
11.2
11.2
11.2
11.2
30
30
32
35
39
30
37
35
40
35
35
38
42
43
43
43
43
52
50
50
50
50
55
55
55
7.1
7.1
7.1
7.9
7.9
8.8
8.8
8.8
8.8
10.6
10.6
10.6
10.6
12.4
12.4
12.4
12.4
12.4
14.7
14.7
14.7
14.7
14.7
14.7
14.7
CT - 696
CT - 354
CT - 549
CT - 657
CT - 858
CT -355
CT - 551
CT - 552
CT - 765
CT - 542
CT -356
CT - 554
CT - 853
CT - 746
CT - 357
CT - 556
CT - 698
CT - 699
CT - 748
CT - 557
CT - 358
CT - 559
CT - 795
CT - 780
CT - 781
Material Copper BS :1977Finish : Electro Tinned
SizeSq. mm Code No.
Dimensions
DE BA JC
1.5
2.5
4
6
10
8
8
10
8
10
10
11.5
10
10
10
11.5
10
12
12
15
12
12
12
14
18
4.2
5.2
6.4
4.2
5.2
6.5
8.4
4.2
5.2
6.5
8.4
5.2
6.5
8.4
10.5
5.2
6.5
8.4
10.5
12.7
5
5
5
7
7
7
7
7
7
7
7
9
9
9
9
9
9
9
10
10
1.8
1.8
1.8
2.4
2.4
2.4
2.4
3.1
3.1
3.1
3.1
3.8
3.8
3.8
3.8
4.5
4.5
4.5
4.7
4.7
16
16
18
18
20
20
24
20
20
20
25
23
27
27
32
25
25
27
32
32
3.7
3.7
3.7
4.0
4.0
4.0
4.0
4.8
4.8
4.8
4.8
5.5
5.5
5.5
5.5
6.2
6.2
6.2
7.1
7.1
CT - 711
CT - 538
CT - 539
CT - 388
CT - 540
CT - 541
CT - 762
CT - 564
CT - 389
CT - 543
CT - 763
CT - 390
CT - 544
CT - 545
CT - 854
CT - 822
CT - 353
CT - 547
CT - 855
CT - 856
Material Copper BS :1977Finish : Electro Tinned
E
CA
BJ
D
SizeSq. mm Code No.
Dimensions
DE BA JC
240
300
400
500
630
800
1000
38
38
38
38
38
43
43
43
43
43
50
50
56
56
65
65
65
72.9
72.9
80.8
80.8
10.5
12.7
15.0
17.0
21.0
10.5
12.7
15.0
17.0
21.0
17.0
21.0
17.0
21.0
--
17.0
21.0
--
21.0
--
21.0
38
38
38
38
42
42
42
42
42
44
44
48
48
56
56
56
78
78
90
90
3821
21
21
21
21
23.5
23.5
23.5
23.5
23.5
26.8
26.8
30
30
35
35
35
39
39
43
43
92
92
92
92
92
101
101
101
101
101
114
114
117
124
144
144
144
170
170
200
200
26.5
26.5
26.5
26.5
26.5
30
30
30
30
30
34.8
34.8
39
39
45
45
45
50.6
50.6
56.2
56.2
CT - 787
CT -705
CT -801
CT - 244
CT - 567
CT - 568
CT - 597
CT - 802
CT - 245
CT - 569
CT - 246
CT - 571
CT - 596
CT - 247
CT - 761
CT - 807
CT - 248
CT - 599
CT - 808
CT - 590
CT - 809
Code No.
Dimensions
DE BA JC
25
25
25
26
26
28
28
28
28
28
28
28
30
30
30
30
30
30
34
34
34
34
34
8.4
10.5
13.0
15.0
17.0
21.0
8.5
10.5
12.7
15.0
17.0
21.0
8.4
10.5
12.7
15.0
17.0
21.0
10.5
12.7
15.0
17.0
21.0
20
20
20
20
22
22
22
22
22
22
22
22
26
26
26
26
26
26
32
32
32
32
32
13.5
13.5
13.5
13.5
13.5
13.5
15.0
15.0
15.0
15.0
15.0
15.0
16.5
16.5
16.5
16.5
16.5
16.5
18.5
18.5
18.5
18.5
18.5
55
55
55
55
60
60
64
64
64
64
64
64
69
69
69
69
69
69
78
78
78
78
78
17.4
17.4
17.4
17.4
17.4
17.4
19.4
19.4
19.4
19.4
19.4
19.4
21.2
21.2
21.2
21.2
21.2
21.2
23.5
23.5
23.5
23.5
23.5
CT - 752
CT - 359
CT - 561
CT - 796
CT - 672
CT - 673
CT - 782
CT - 700
CT - 241
CT - 797
CT - 546
CT - 798
CT - 783
CT - 676
CT - 242
CT - 799
CT - 564
CT - 565
CT - 652
CT - 639
CT - 800
CT - 243
CT - 704
SizeSq. mm
95
120
150
185
EXTENDED PALM BLANKS COPPER CRIMPING TERMINAL ENDS FOR COPPER CONDUCTORSBraco Copper Long Palm Terminals are
manufactured from Electrolytic Copper tube. These are used where more secured termination is required as it can easily accommodate two bolts to reduce drift. All terminals are standard with blank palm and stud holes can be punched to order. These terminals are normally used in vibrating applications. The presence of inspection hole facilitates full insertion of conductor. The terminals are tin plated to avoid oxidization and to achieve maximum corrosion protection.
SizeSq. mm Code No.
Dimensions
BA G+HC JD
50
70
95
120
150
185
240
300
400
500
625
16
18
20
22
26
32
38
42
44
48
56
9.5
11.2
13.5
15.0
16.5
18.5
21.0
23.5
28.5
30.0
35.0
42
50
52
56
64
68
80
88
104
112
132
12.4
14.7
17.4
19.4
21.2
23.5
26.5
30.0
36.5
39.0
45.0
64
75
81
88
101
112
132
145
166
180
210
18
21
25
28
30
34
38
43
53
56
65
CT - 466
CT - 467
CT - 468
CT - 469
CT - 470
CT - 471
CT - 472
CT - 473
CT - 474
CT - 475
CT - 476
Material Copper BS :1977Finish : Electro Tinned
DJ
BG+H
AC
Cable mm2
Stud Hole Dimensions (mm2) Cat No.
E A C B D G H J5.36.56.58.56.58.4
10.513.0
6.58.4
10.513.0
8.410.513.0
8.410.513.017.010.513.017.021.010.513.017.021.010.513.017.021.010.513.017.021.010.513.017.021.010.513.017.021.013.017.021.017.021.021.021.0
3.83.84.54.55.55.55.55.57.07.07.07.08.28.28.2
10.010.010.010.011.511.511.511.513.513.513.513.515.515.515.515.517.017.017.017.019.019.019.019.021.521.521.521.524.024.024.027.527.531.034.5
5.55.56.06.08.58.58.58.5
10.010.010.010.012.512.512.514.514.514.514.516.516.516.516.519.019.019.019.021.021.021.021.023.523.523.523.525.525.525.525.529.029.029.029.032.032.032.038.538.542.044.0
1010101020202020202020202020202828282828282828353535353535353535353535404040404040404050505070707080
8.58.58.58.512121719151517191719212222232824243232282832343232323234343440373737404242424648484855556060
6.57.57.5
10.07.5
10.012.013.0
7.510.012.013.0
7.510.012.010.012.013.014.510.012.013.014.512.012.013.014.518.019.015.016.015.016.019.016.015.016.019.019.015.016.019.021.019.019.021.025.025.025.025.0
7.58.08.0
10.08.0
10.012.013.0
8.010.012.013.0
8.010.012.010.012.013.014.510.012.013.014.512.012.013.014.516.017.019.020.016.017.020.020.016.017.020.020.016.017.020.020.022.022.022.025.025.025.025.0
31323537434549504749515250525461636466646667697676808283848788929396969697
100100106107110112119119121140140152160
6-5 DIN6-6 DIN
10-6 DIN10-8 DIN16-6 DIN16-8 DIN
16-10 DIN16-12 DIN25-6 DIN25-8 DIN
25-10 DIN25-13 DIN35-8 DIN
35-10 DIN35-12 DIN50-8 DIN
50-10 DIN50-12 DIN50-16 DIN70-10 DIN70-12 DIN70-16 DIN70-20 DIN95-10 DIN95-12 DIN95-16 DIN95-20 DIN
120-10 DIN120-12 DIN120-16 DIN120-20 DIN150-10 DIN150-12 DIN150-16 DIN150-20 DIN185-10 DIN185-12 DIN185-16 DIN185-20 DIN240-10 DIN240-12 DIN240-16 DIN240-20 DIN300-12 DIN300-16 DIN300-20 DIN400-16 DIN400-20 DIN500-20 DIN652-20 DIN
6
10
16
25
35
50
70
95
120
150
185
240
300
500
625
400
Braco copper tube terminals are manufactured from Electrolytic Copper Tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cable, electrical switching equipments, where vibration is critical.
Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In application subject to vibration terminals still have to perform a reliable connection, annealing plays a vital role in avoiding crackings or breaks between the barrel and palm.
The terminals are designed as per DIN standard 46235. The plating on the terminals avoids oxidization and achieves maximum corrosion protection.
COPPER CRIMPING TERMINALS AS PER DIN STANDARDSBraco Copper Long Barrel Tube Terminals are made from high purity copper tube and are annealed to avoid cracking or breaks. The increased barrel length ensures enhanced electrical and mechanical performance in heavy duty application. The absence of an inspection hole prevents the entry of water or moisture into crimped joints making them suitable for outdoor applications. The terminals are tin plated to avoid oxidization and to achieve maximum corrossion protection.
COPPER CRIMPING TERMINALS FOR COPPER CONDUCTORS (LONG BARREL)
Material Copper BS :1997Finish : Electro Tinned
SizeSq. mm Code No.
Dimensions
DE BA JC
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
13.0
15.0
17.0
20.0
24.0
28.0
30.0
34.0
40.0
43.0
50.0
56.0
65.0
72.9
80.8
8.2
8.2
8.2
10.5
12.7
12.7
12.7
12.7
16.2
16.2
20.3
21.0
21.0
-
-
16
20
26
28
32
35
38
43
50
55
58
48
76
105
130
7.0
8.0
9.2
11.5
12.8
14.8
16.0
18.0
22.0
23.5
26.8
30
35
39
43
41
48
59
66
74
82
86
95
112
120
135
124
165
200
240
9.0
10.6
12.2
15.0
17.0
19.6
21.2
24.0
28.0
30.0
34.8
39.00
45.0
50.6
56.2
CT - 82
CT - 83
CT - 84
CT - 85
CT - 86
CT - 87
CT - 88
CT - 89
CT - 90
CT - 91
CT - 92
CT - 93
CT - 94
CT - 95
CT - 96
E
B
J
CA
D
Braco connectors are designed for jointing low voltage conductors. Made of electrolytic copper tube having the same dimension as CT series lugs, Braco connectors are annealed and electrolytic ally tin plated. They feature an internal taper at both ends to ease the introduction of conductor and a dimple (if required) to ensure correct positioning. These connectors can also be provided with insulation. Tinning on connectors provides better finish, avoids oxidisation and achieves maximum corrossion protection
COPPER TUBE IN-LINE CONNECTORS
(Short Barrel)
ILC-453
ILC-454
ILC-3
ILC-4
ILC-460
ILC-6
ILC-24
ILC-25
ILC-26
ILC-51
ILC-52
ILC-53
ILC-54
ILC-55
ILC-56
ILC-57
ILC-58
ILC-59
ILC-61
ILC-62
ILC-63
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
800
1000
1.6
2.4
3.1
3.8
4.5
5.4
6.8
8.2
9.5
11.2
13.5
15.0
16.5
18.5
21.0
23.5
26.8
30.0
35.0
39.0
43.0
3.2
4.0
4.8
5.5
6.2
7.1
8.8
10.6
12.4
14.7
17.4
19.4
21.2
23.5
26.8
30.0
34.8
39.0
45.0
50.6
56.2
15.0
15.0
15.0
15.0
20.0
20.0
32.0
36.0
40.0
40.0
45.0
45.0
55.0
65.0
80.0
85.0
90.0
100.0
110.0
150.0
170.0
BracoCat. No.
SizeSq. mm.
Dimensions
d1 d3 J
ILC-41
ILC-42
ILC-43
ILC-44
ILC-45
ILC-46
ILC-47
ILC-48
ILC-49
ILC-27
ILC-28
ILC-29
ILC-30
ILC-31
ILC-32
ILC-33
ILC-34
ILC-35
ILC-36
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
1.6
2.4
3.1
3.8
4.5
5.4
6.8
8.2
9.5
11.2
13.5
15.0
16.5
18.5
21.0
23.5
26.8
30.0
35.0
3.2
4.0
4.8
5.5
6.2
7.1
8.8
10.6
12.4
14.7
17.4
19.4
21.2
23.5
26.8
30.0
34.8
39.0
45.0
22.0
22.0
22.0
22.0
22.0
35.0
47.0
45.0
50.0
50.0
60.0
65.0
70.0
75.0
89.0
95.0
110.0
117.0
120.0
BracoCat. No.
SizeSq. mm.
Dimensions
d1 d3 J
(Long Barrel)
CA
J
COPPER IN-LINE CONNECTORS
SizeSq. mm Code No.
Dimensions
A1A C1C J1J
1.5
2.5
4.5
3.3
4.1
5.6
1.6
2.4
3.5
3.2
4.0
5.5
25
25
27
15
15
15
ILCI - 63
ILCI - 64
ILCI - 65
4.9
5.5
7.2
1.5 2.5 4.6
Colour Coding Insulated Terminals:
J-1
A1C1 AC
J
COPPER CRIMPING REDUCER TERMINALS FOR ALUMINIUM CONDUCTORBraco Copper Crimping Reducer Terminals are
used to terminate one or more Aluminium conductors to a smaller termination area. These type of terminals are applicable in tunnel type terminal blocks viz. fuse gears, cut-outs, meters etc. Braco is able to produce any Copper Reducing Link that you may require. The presence of copper at termination end ensures high current carrying capacity at smaller surface area. Tinning avoids oxidisation and provides maximum corrosion protection.
Material : Copper BS 1977Finish : Electro Tinned
SizeSq. mm Code No.
Dimensions
D-1A BC JD
2.5
4
6
10
16
25
35
50
4.0
3.3
4.0
3.3
4.0
3.3
4.0
3.3
4.0
3.3
5.5
5.5
3.3
5.5
6.5
6.5
6.5
13.0
2.5
2.5
2.8
2.8
3.1
3.1
3.8
3.8
4.4
4.4
5.3
5.3
5.3
7.0
7.0
8.0
9.2
10.4
6
6
6
6
6
6
9
9
9
9
12
12
12
12
12
12
16
18
4.7
4.7
4.7
4.7
4.7
4.7
5.5
5.5
6.2
6.2
7.1
7.1
7.1
9.0
9.0
10.0
11.2
14.0
20
20
20
20
20
20
23
23
23
23
32
37
30
32
37
37
41
49
4.5
3.8
4.5
3.8
4.5
3.8
4.5
3.8
4.5
3.8
6.0
6.0
3.8
6.0
7.5
7.5
7.5
14.0
WPC - 1
WPC - 7
WPC - 15
WPC - 16
WPC - 17
WPC - 18
WPC - 19
WPC - 20
WPC - 21
WPC - 22
WPC - 23
WPC - 24
WPC - 2
WPC - 25
WPC - 3
WPC - 4
WPC - 26
WPC - 5
SizeSq. mm Code No.
Dimensions
D-1A BC JD
70
95
120
150
185
225
240
300
400
6.5
10.5
10.5
10.5
6.5
11.8
6.5
10.5
14.0
10.5
14.0
10.5
14.0
15.0
14.0
15.0
14.0
14.0
11.5
11.5
11.5
12.8
12.8
12.8
14.8
14.8
16.0
16.0
18.0
18.0
20.0
22.0
22.0
24.0
24.0
27.0
18
18
18
20
20
20
22
22
26
26
32
32
38
38
38
42
42
46
13.8
13.8
13.8
15.6
15.6
15.6
17.8
17.8
19.6
19.6
22.0
22.0
26.0
26.0
26.0
28.7
28.7
33.2
43
48
55
51
48
58
50
60
64
64
70
70
78
88
78
92
82
90
7.5
11.5
11.5
11.5
7.5
12.8
7.5
11.5
15.6
11.5
15.6
11.5
15.6
16.0
16.0
16.0
16.0
16.0
WPC - 27
WPC - 6
WPC - 28
WPC - 29
WPC - 31
WPC - 32
WPC - 34
WPC - 35
WPC - 10
WPC - 37
WPC - 30
WPC - 38
WPC - 39
WPC - 44
WPC - 43
WPC - 45
WPC - 47
WPC - 101
J
AC
D
D1
Braco Bi-metallic terminals for aluminium conductor are manufactured from solid materials by friction welding. This method means that aluminium and Copper join through the heat, which develops when aluminium rotates against copper under pressure. This is a superior method to give a complete connection between Aluminium and Copper. Barrels are caped and filled with grease so as to avoid oxidisation of the aluminium.
BI-METALLIC TERMINALS
Material : Aluminium 99.5, E CopperSurface : Bright
16 13 5.5 16 24 87 BMT-16
25 13 6.5 16 24 87 BMT-25
35 13 8.0 16 24 87 BMT-35
50 13 9.0 20 24 87 BMT-50
70 13 11.0 20 24 87 BMT-70
95 13 12.5 20 24 87 BMT-95
120 13 13.7 25 31 111 BMT-120
150 13 15.5 25 31 111 BMT-150
185 13 17.0 32 35 116 BMT-185
240 13 19.5 32 35 116 BMT-240
300 13 22.5 34 35 120 BMT-300
SIZESq.mm. E A C D J
CAT NO.Dimension
JC
A
D
E
BI-METALLIC PIN TERMINALSBraco Bi-metallic Connectors are made from aluminium purity equal to or greater than 99.5 %. The barrel is friction welded to the pin thus achieving the best possible transition between the copper pin and aluminium barrel.Barrels are capped and filled with grease so as to avoid oxidisation of the aluminium.
Material : Aluminium 99.5; E CopperSurface : Bright
16 5.5 16 8 30 82 BMP-16
25 6.5 16 8 30 82 BMP-25
35 8.0 16 8 30 82 BMP-35
50 9.0 20 12 45 97 BMP-50
70 11.0 20 12 45 97 BMP-70
95 12.5 20 12 45 97 BMP-95
120 13.7 25 14 55 125 BMP120
150 15.5 25 14 55 125 BMP-150
185 17.0 32 14 55 125 BMP-185
240 19.5 32 14 55 125 BMP 240
SIZESq.mm. A C D-1 J
CAT NO.P
DIEMENSIONS
D1
CAJ
P
Braco Aluminium Crimping Terminals are manufactured out of tubes of purity equal to or greater than 99.5%, hav ing max imum conductivity not less than 60% IACS and are designed as per IS 8309 1993 These are used for terminating all sizes of cables to terminate electrical switching equipments. The absence of an inspection hole prevents the entry of water or moisture into crimped joints making them suitable for outdoor applications.
ALUMINIUM CRIMPING TERMINALS
Material : Aluminium IS: 5082 :1981
SizeSq. mm Code No.
Dimensions
DE BA JC
2.5
4
6
10
16
25
35
50
70
7
7
7
12
8
12
10
15
11
11
18
14
14
20
20
15
15
20
18
23
23
22
22
22
3.2
3.7
4.2
5.2
5.2
6.4
6.4
8.2
6.4
8.2
10.2
6.4
8.2
10.2
12.7
6.4
8.2
10.2
8.2
10.2
12.7
8.2
10.2
12.7
7
7
7
7
7
7
9
9
13
13
13
16
16
16
16
18
18
18
22
22
22
26
26
26
2.0
2.6
2.9
2.9
3.5
3.5
4.4
4.4
5.4
5.4
5.4
7.0
7.0
7.0
7.0
8.0
8.0
8.0
9.3
9.3
9.3
11.6
11.6
11.6
18
18
18
24
24
24
30
30
37
37
37
44
44
44
44
47
47
47
54
54
54
60
60
60
5.5
5.5
5.5
5.5
5.5
5.5
7.4
7.4
8.3
8.3
8.3
10.0
10.0
10.0
10.0
10.8
10.8
10.8
13.0
13.0
13.0
16.0
16.0
16.0
AT - 151
AT - 309
AT - 155
AT - 317
AT - 158
AT - 313
AT - 214
AT - 215
AT - 252
AT - 216
AT - 217
AT - 253
AT - 218
AT - 219
AT - 220
AT - 254
AT - 221
AT - 222
AT - 255
AT - 312
AT - 224
AT - 256
AT - 225
AT - 226
ALUMINIUMALUMINIUMALUMINIUMALUMINIUM
E
CA
BJ
D
SizeSq. mm Code No.
Dimensions
DE BA JC
95
120
150
185
225
240
300
400
500
630
800
1000
25.0
25.0
25.0
28.0
28.0
28.0
31.0
31.0
31.0
34.0
34.0
34.0
39.0
40.0
40.0
40.0
45.7
45.7
51.0
58.0
66.0
73.0
81.0
10.2
12.7
16.2
10.2
12.7
16.2
10.2
12.7
16.2
10.2
12.7
16.2
12.7
12.7
16.2
20.0
16.2
20.3
20.3
20.3
20.3
--
--
28
28
28
32
32
32
34
34
34
36
36
36
40
44
44
44
47
47
56
60
69
77
100
12.9
12.9
12.9
14.8
14.8
14.8
16.1
16.1
16.1
18.0
18.0
18.0
20.6
22.0
22.0
22.0
24.0
24.0
28.0
30.0
35.0
39.0
43.5
64
64
64
73
73
73
79
79
79
84
84
84
94
102
102
102
115
115
130
140
154
180
220
17.1
17.1
17.1
19.6
19.6
19.6
21.2
21.2
21.2
23.7
23.7
23.7
27.0
28.0
28.0
28.0
31.0
31.0
36.0
41.0
46.0
51.0
57.0
AT - 227
AT - 228
AT - 229
AT - 257
AT - 230
AT - 231
AT - 258
AT - 232
AT - 233
AT - 311
AT - 234
AT - 235
AT - 320
AT - 236
AT - 237
AT - 238
AT - 300
AT - 259
AT - 260
AT - 296
AT - 261
AT - 318
AT - 319
Braco AT - XL type of terminals are manufactured out of tubes of purity equal to or greater than 99.5% having maximum conductivity not less than 60% IACS and are suitable for high voltage application where termination of XLPE cable is required.
ALUMINIUM TUBE TERMINALS FOR AL-XLPE CONDUCTORS
SizeSq. mm
Code No.
Dimensions
DE BA JG+HC
25
35
50
70
95
120
150
185
225
240
300
400
500
630
800
1000
14
16
19.5
20.5
23.5
26.5
29.5
33.0
36.0
37.5
42.0
48.0
54.0
61.0
68.0
77.5
8.2
8.2
10.2
10.2
12.7
12.7
12.7
12.7
12.7
12.7
20.3
20.3
20.3
20.3
20.3
20.3
41
50
49
62
73
73
83
83
86
86
89
113
125
140
147
160
21
22
24
26
28
30
34
36
40
44
54
60
64
68
78
90
7.2
8.3
9.3
10.2
12.0
13.7
15.1
16.6
18.6
19.3
21.8
25.0
28.2
31.7
35.7
41.0
69
79
81
96
109
114
128
131
140
144
157
187
205
225
250
280
9.6
11.1
13.5
14.5
16.6
19.0
21.1
23.9
26.1
27.2
30.2
34.8
39.1
44.4
49.5
56.0
AT - XL 17
AT - XL 18
AT - XL 19
AT - XL 20
AT - XL 21
AT - XL 22
AT - XL 23
AT - XL 24
AT - XL 25
AT - XL 26
AT - XL 27
AT - XL 28
AT - XL 29
AT - XL 30
AT - XL 31
AT - XL 32
Material : Aluminium IS :5082 1981:
E
CA
BJ
D
E
BJ
CA
D
ALUMINIUM CRIMPING CONNECTORBraco Aluminium Crimping In-Line Connectors are made out of tubes of purity equal to or greater than 99.5% having maximum conductivity not less than 60% IACS and the designed as per IS 8309 1993. These connectors facilitate joining two identical size Aluminium conductors.
SizeSq. mm Code No.
Dimensions
A C J
2.5
4
6
10
16
25
35
50
70
95
120
150
185
225
240
300
400
500
630
800
1000
2.0
2.6
2.9
3.5
4.4
3.8
5.4
7.0
8.0
9.3
11.6
12.9
14.8
16.1
18.0
20.6
22.0
24.0
28.0
30.0
35.0
39.0
43.5
5.5
5.5
5.5
5.5
7.4
6.2
8.3
10.0
10.8
13.0
16.0
17.1
19.6
21.2
23.7
27.0
28.0
31.0
36.0
41.0
46.0
51.0
57.0
16
16
16
16
20
20
26
35
40
45
55
60
65
70
75
85
90
100
115
125
140
160
210
ILA - 145
ILA - 6
ILA - 5
ILA - 13
ILA - 14
ILA - 146
ILA - 4
ILA - 3
ILA - 2
ILA - 12
ILA - 1
ILA - 15
ILA - 9
ILA - 10
ILA - 11
ILA - 147
ILA - 16
ILA - 17
ILA - 18
ILA - 19
ILA - 20
ILA - 148
ILA - 149
Material : Aluminium IS :5082 :1981
Braco Aluminium Reducer Terminals are manufactured out of aluminium of purity equal to or greater than 99.5 % having maximum coductivity not less than 60% IACS. These are used to terminate one or more Aluminium conductors to a smaller termination area. Braco is able to produce any Aluminium Reducing Link that you may require.
ALUMINIUM CRIMPING REDUCER TERMINALS FOR ALUMINIUM CONDUCTOR
SizeSq. mm Code No.
Dimensions
D-1A BC JD
2.5
4
6
10
16
25
35
50
70
4.0
3.3
4.0
3.3
4.0
3.3
4.0
3.3
4.0
3.3
5.5
5.5
3.3
5.5
6.5
6.5
6.5
13.0
6.5
10.5
10.5
2.6
2.6
2.9
2.9
3.5
3.5
3.8
3.8
4.4
4.4
5.4
5.4
5.4
7.0
7.0
8.0
9.3
10.4
11.6
11.6
11.6
7
7
7
7
7
7
9
9
9
9
13
13
13
16
16
18
22
22
26
26
26
5.5
5.5
5.5
5.5
5.5
5.5
7.4
7.4
7.4
7.4
8.3
8.3
8.3
10.0
10.0
10.8
13.0
14.0
16.0
16.0
16.0
21
21
21
21
21
21
23
23
23
23
33
38
31
36
41
43
47
53
51
56
63
4.5
3.5
4.5
3.8
4.5
3.8
4.5
3.8
4.5
3.8
6.0
6.0
3.8
6.0
7.5
7.5
7.5
14.0
7.5
11.5
11.5
WPA - 1
WPA - 7
WPA - 15
WPA - 16
WPA - 17
WPA - 18
WPA - 19
WPA - 20
WPA - 21
WPA - 22
WPA - 23
WPA - 24
WPA - 2
WPA - 25
WPA - 3
WPA - 4
WPA - 26
WPA - 5
WPA - 27
WPA - 6
WPA - 28
Material : Aluminium IS :5082 :1981
J
AC
D
D1
C A
J
SizeSq. mm Code No.
Dimensions
D-1A BC JD
95
120
150
185
240
300
10.5
14.0
6.5
11.8
10.5
6.5
10.5
14.0
14.0
14.0
14.0
10.5
14.0
18.0
15.0
15.0
14.0
15.0
14.0
12.9
12.9
12.9
12.9
14.8
14.8
14.8
14.8
16.1
16.1
18.0
18.0
20.6
20.6
20.6
22.0
22.0
24.0
24.0
28
28
28
28
32
32
32
32
34
34
36
36
40
40
40
44
44
47
47
17.1
17.1
17.1
17.1
19.6
19.6
19.6
19.6
21.2
21.2
23.7
23.7
27.0
27.0
27.0
28.0
28.0
31.0
31.0
59
61
56
66
63
60
70
70
72
72
74
74
80
90
90
94
84
94
84
11.5
15.6
7.5
12.8
11.5
7.5
11.5
15.6
15.6
15.6
15.6
11.5
15.6
21.0
16.0
16.0
15.6
16.0
15.6
WPA - 29
WPA - 8
WPA - 31
WPA - 32
WPA - 33
WPA - 34
WPA - 35
WPA - 36
WPA - 10
WPA - 37
WPA - 30
WPA - 38
WPA - 39
WPA - 46
WPA - 42
WPA - 44
WPA - 43
WPA - 45
WPA - 47
Braco long barrel aluminium crimping terminals are manufactured out tubes drawn to the required sizes having minimum conductivity not less than 60% IACS and as per IS 158309 1993
These are used for terminating all sizes of cables to terminate electrical switching equipments. The increased barrel length ensures enhanced electrical and mechanical performance due to more number of crimps. The absence of inspection hole prevents the entry of water or moisture into crimped joints making them suitable for outdoor applications.
LONG BARREL ALUMINIUM CRIMPING TERMINALS FOR ALUMINIUM CONDUCTOR
2.5
2.5
4
4
6
6
10
10
16
16
16
25
25
25
35
35
50
50
50
70
70
70
95
95
95
120
120
120
150
150
150
185
185
185
225
240
240
300
300
400
500
630
800
1000
3.2
3.7
4.2
5.2
5.2
6.4
6.4
8.2
6.4
8.2
10.2
8.2
10.2
12.7
8.2
10.2
8.2
10.2
12.7
8.2
10.2
12.7
10.2
12.7
16.2
10.2
12.7
16.2
10.2
12.7
16.2
10.2
12.7
16.2
12.7
12.7
16.2
16.2
20.3
20.3
20.3
20.3
-
-
2.0
2.6
2.9
2.9
3.5
3.5
4.4
4.4
5.4
5.4
5.4
7.0
7.0
7.0
8.0
8.0
9.3
9.3
9.3
11.6
11.6
11.6
12.9
12.9
12.9
14.8
14.8
14.8
16.1
16.1
16.1
18.0
18.0
18.0
20.6
22.0
22.0
24.0
24.0
28.0
30.0
35.0
39.0
43.5
5.5
5.5
5.5
5.5
5.5
5.5
7.4
7.4
8.3
8.3
8.3
10.0
10.0
10.0
10.8
10.8
13.0
13.0
13.0
16.0
16.0
16.0
17.1
17.1
17.1
19.6
19.6
19.6
21.2
21.2
21.2
23.7
23.7
23.7
27.0
28.0
28.0
31.0
31.0
36.0
41.0
46.0
51.0
57.0
7.0
7.0
7.0
12.0
8.0
12.0
10.0
15.0
11.0
11.0
18.0
14.0
20.0
20.0
15.0
20.0
18.0
23.0
23.0
22.0
22.0
22.0
25.0
25.0
25.0
28.0
28.0
28.0
31.0
31.0
31.0
34.0
34.0
34.0
39.0
40.0
40.0
45.7
45.7
51.0
58.0
66.0
73.0
81.0
10.5
10.5
10.5
10.5
10.5
10.5
13.5
13.5
19.5
19.5
19.5
24.0
24.0
24.0
27.0
27.0
33.0
33.0
33.0
39.0
39.0
39.0
42.0
42.0
42.0
48.0
48.0
48.0
51.0
51.0
51.0
54.0
54.0
54.0
60.0
66.0
66.0
70.5
70.5
84.0
90.0
103.5
115.5
150.0
21.5
21.5
21.5
27.5
27.5
27.5
34.5
34.5
43.5
43.5
43.5
52.0
52.0
52.0
56.0
56.0
65.0
65.0
65.0
73.0
73.0
73.0
78.0
78.0
78.0
89.0
89.0
89.0
96.0
96.0
96.0
102.0
102.0
102.0
114.0
124.0
124.0
138.5
138.5
158.0
170.0
188.5
218.5
270.0
AT- 551
AT- 509
AT- 555
AT-517
AT-558
AT-513
AT-514
AT-515
AT-552
AT-516
AT-517
AT-518
AT-519
AT-520
AT-521
AT-522
AT-655
AT-512
AT-524
AT-556
AT-525
AT-526
AT-527
AT-528
AT-529
AT-557
AT-530
AT-531
AT-658
AT-532
AT-533
AT-511
AT-534
AT-535
AT-620
AT-536
AT-537
AT-500
AT-559
AT-560
AT-596
AT-561
AT-618
AT-619
E A C D B J CAT NOCABLE SIZE
MM2
Dimensions
Material : Aluminium IS :5082 :1981
J
AC
D
D1
E
B
J
CA
D
Braco double hole Aluminium crimping terminals which are also known as "Non Rotating Terminals" are manufactured out of tubes drawn to the required sizes having minimum conductivity not less than 60% IACS . The increased barrel length ensures enhanced electrical and mechanical performance due to more number of crimps. Two holes ensures non-rotation in the equipments such as transformers,moving equipments where vibration is critical.The holes can be punched as per requirement.
DOUBLE HOLE ALUMINIUM CRIMPING TERMINALS FOR
ALUMINIUM CONDUCTORS
35
50
70
95
120
150
185
240
300
400
500
12
12
12
12
12
16
16
16
16
16
16
8
9.7
11
13.1
14.7
16.5
18.1
21
23.2
26
29
15
18
18
20
22
25
31
31
38
40
45
22
25
25
28
32
36
45
45
55
58
65
44
44
44
44
44
44
44
44
44
44
44
50
50
62
73
73
83
83
86
89
113
125
133
133
145
157
160
174
175
180
183
207
221
ATT-35-12
ATT-50-12
ATT-70-12
ATT-95-12
ATT-120-12
ATT-150-16
ATT-185-16
ATT-240-16
ATT-300-16
ATT-400-16
ATT-500-16
E A C D G B J CAT NOCABLE SIZE
MM2
Dimensions
Material : Aluminium IS :5082 :1981
ALUMINIUM ALLOY TUBULAR BIMETALLIC TERMINALSBraco Aluminium alloy tubular bi-metallic terminals are manufactured out of aluminium of purity equal to or greater than 99.5 % having maximum coductivity not less than 60% IACS. These are anti-corrosive and used for highly corrosive environment. The barrels are kept filled with grease so as to avoid oxidization of the Aluminium. These are designed to accept a variety of conductor forms especially low stranded compacted conductors.These terminals are mainly used to terminate on copper bus bars. Whenever aluminium links terminated on to copper or copper based alloy terminals without suitable plating, results in the corrossion of the joint over a period leading to higher joint resistance.Bi-metallic terminals are found most reliable and suitable for such connections.
150
185
225
240
300
400
500
630
800
1000
16.1
16.1
18.0
18.0
20.6
22.0
22.0
24.0
24.0
28.0
30.0
35.0
39.0
43.5
12
16
12
16
12
12
16
16
20
20
20
20
--
--
34
34
36
36
40
44
44
47
47
56
60
69
77
100
21.2
21.2
23.7
23.7
27.0
28.0
28.0
31.0
31.0
36.0
41.0
46.0
51.0
57.0
79
79
84
84
94
102
102
115
115
130
140
154
180
220
31.0
31.0
34.0
34.0
39.0
40.0
40.0
45.7
45.7
51.0
58.0
66.0
73.0
81.0
ATB - 17
ATB - 18
ATB - 19
ATB - 20
ATB - 21
ATB - 22
ATB - 23
ATB - 24
ATB - 25
ATB - 26
ATB - 27
ATB - 28
ATB - 29
ATB - 30
SizeSq. mm Code No.
Dimensions
AE BC JD
SizeSq. mm Code No.
Dimensions
AE BC JD
10
16
25
35
50
70
95
120
4.4
4.4
5.4
5.4
7.0
7.0
8.0
8.0
9.3
9.3
11.6
11.6
12.9
12.9
14.8
14.8
6
8
6
8
8
10
8
10
8
10
10
12
10
12
10
12
30
30
37
37
44
44
47
47
54
54
60
60
64
64
73
73
ATB - 1
ATB - 2
ATB - 3
ATB - 4
ATB - 5
ATB - 6
ATB - 7
ATB - 8
ATB - 9
ATB - 10
ATB - 11
ATB - 12
ATB - 13
ATB - 14
ATB - 15
ATB - 16
7.4
7.4
8.3
8.3
10.0
10.0
10.8
10.8
13.0
13.0
16.0
16.0
17.1
17.1
19.6
19.6
10
15
11
11
14
20
15
20
18
23
22
22
25
25
28
28
9
9
13
13
16
16
18
18
22
22
26
26
28
28
32
32
Material : Aluminium IS :5082 :1981
J
B
AC
E
D
E
B
J
CA
D
Characteristics:
Installation Instructions :
SINGLE COMPRESSION GLANDSBraco single compression Brass Cable Glands are suitable for armoured / unarmoured cables. These are manufactured out of brass castings and are machined accurately to the required sizes These glands are nickel plated to avoid corrosion while storage and use.
Each gland comprises of Brass Body with nipple thread as per I.S. 1653 Compression nut, Check nut, Rubber Ring and three metal washers. The detail parts are shown in the functional drawing.
These glands are weather proof and watertight and have provision for earthing the armoured cables. These glands are available in various different sizes and are suitable for all cables up to 1000 sq.mm. and control cables up to 61 cores The entry thread on gland body is normally threaded according to IS 1653 (Steel conduits for electrical wiring). However if any special kind of thread required, the same can be supplied. The glands can be supplied with special plating such as cadmium, tin or passivated.
• Washers of soft metal will be provided for firm gripping of armour• Earth tag will be provided if required at extra cost • PVC protective shrouds can be supplied at extra cost. • Washers between rubber ring are supplied for uniform radial gripping.
Characteristics
Selection
•• Diameter of cable underneath the overall sheating for unarmoured cable and
underneath the armouring for armoured cables is not more than D-34.• Selection of rubber ring is made such that the dia over armouring for armoured
cables and dia underneath the overall sheathing for unarmoured cable is less than rubber I.D. A-1.
O. D of cable should be less than D-3
Parts
1. Compression Nut2. Brass Body3. Three Metal Washers4. Rubber Ring5. Check Nut
Material
Brass
Finish
Nickle Plated
Glands Ref.NIP. OD CAP. BORING NIP. ID A.CROSS. BODY HIGHT NIP. HIGHT B. NUT RUB. ID Cable diameter (mm)
E D-3 D-3 A D L-9 L-10 M A-1 above upto
BC-3/8" 1/2" 14.00 12.00 20.00 10.50 6.00 2.00 8.00 9 13.5
BC-1/2"L 5/8" 15.00 13.00 23.00 12.50 6.50 2.00 12.00 10 14.5
BC-1/2"H 5/8" 15.00 13.00 23.50 14.00 7.50 3.00 12.00 10 14.5
BC-5/8"L 3/4" 15.00 15.00 23.00 14.00 7.00 2.00 12.00 10 14.5
BC-5/8"H 3/4" 15.00 15.00 23.50 15.00 8.00 3.00 12.00 10 14.5
BC-3/4"L 3/4" 17.50 15.00 26.00 15.50 8.00 2.50 14.00 14 17
BC-3/4"H 3/4" 17.50 15.00 27.50 16.50 9.00 3.00 14.00 14 17
BC-7/8"L 3/4" 20.00 15.00 29.00 16.00 8.00 2.50 16.00 17 19.5
BC-7/8"H 3/4" 20.00 15.00 29.50 17.00 9.00 3.00 16.00 17 19.5
BC-1"L 1" 23.50 21.50 32.50 17.50 8.00 3.00 20.00 19.5 23
BC-1"H 1" 23.50 21.00 34.50 19.00 10.00 3.50 20.00 19.5 23
BC-1"S 3/4" 23.50 15.00 32.50 17.50 8.00 3.00 18.00 19.5 23
BC-1-1/8" 1-1/8" 28.00 25.00 39.00 21.00 10.50 4.00 25.00 23 27
BC-1-1/4" 1-1/4" 31.50 27.00 42.50 21.00 10.50 4.00 27.00 27 30
BC-1-3/8" 1-3/8" 35.50 31.00 47.50 22.00 10.50 4.50 31.00 30 34
BC-1-1/2" 1-1/2" 39.00 34.00 52.00 22.00 10.50 4.50 33.00 34 38
BC-1-3/4" 1-3/4" 45.00 40.00 59.00 23.00 11.50 4.50 39.00 38 44
BC-2" 2" 51.50 45.00 68.00 23.00 11.50 4.50 44.00 44 50
BC-2-1/4" 2-1/4" 58.00 52.00 75.00 23.50 11.50 5.00 52.00 50 56.5
BC-2-1/2" 2-1/2" 62.50 58.00 80.00 25.00 13.00 5.50 58.00 56.5 61
BC-2-3/4" 2-3/4" 70.00 65.50 90.00 28.00 13.50 5.50 65.00 61 68
BC-3" 3" 76.00 69.50 100.00 28.00 13.50 5.50 70.00 68 74
BC-3-1/4" 3-1/4" 82.00 75.00 115.00 29.00 15.00 5.50 75.00 74 80
BC-3-1/2" 3-1/2" 88.00 82.00 117.00 29.00 15.00 6.00 80.00 80 86
BC-4" 4" 100.00 92.50 127.00 36.00 20.00 6.00 86.00 86 98
BC-4-1/2" 4-1/2" 108.00 102.00 145.00 38.00 23.00 7.00 90.00 98 105
A-1
B-1
D-3
L-9
M
L-10
FU
NC
TIO
NA
L D
ES
IGN
D Across Corner
D-3
E
DOUBLE COMPRESSION GLANDS ( Weather Proof )Braco Double Compression glands are manufactured out of brass rods/castings and are machined accurately to the required sizes. These are nickel plated to avoid corrosion whilst storage and use.
These glands have two moisture proof seals and may be used under most climatic conditions. These are weather proof and waterproof and when protected by a PVC shroud these can be used under most corrosive conditions. The armour cone and ring gives excellent mechanical and electrical connections.
These glands are as per BS6121 1973 and have ten parts: Brass Body, Armour Clamp and Ring, Gland Barrel sealing nut, two pcp seals, the skid washer check nut and flat washer between the gland barrel and check nut is provided to prevent the drag on outer seal. The detail parts are shown in functional drawing.
These glands are available in various different sizes and are suitable for all cables up to 1000 sq.mm. and control cables up to 61 cores. The entry threads on gland barrel are normally threaded according to IS 1653 (Steel conduits for electrical wiring), however if any special kind of gland or thread is required, the same can be supplied on request.
The gland can also be supplied with any other special plating such as cadmium, tin or pasivated. Also the glands can be supplied made out of aluminium, mild steel or stainless steel.
Characteristics:•• Earthing tag will be provided if required at extra cost.• PVC protective shroud can be supplied at extra cost.• Washers between seals are supplied for uniform radial gripping of PCP seals.
Clamping cone will be provided with knurling for firm gripping of the armour.
BRACOCAT. No.
B A E E
NippleBSC
(INCH)D Max. Accept. Dia
From To
BPW 3/8”
BPW ½”
BPW 5/8”
BPW 001
BPW 01
BPW 01L
BPW 02
BPW 02S
BPW 03
BPW 04
BPW 04L
BPW 05
BPW 06
BPW 06S
BPW 07
BPW 08
BPW 09
BPW 010
BPW 011
BPW 012
BPW 013
BPW 014
BPW 015
BPW 016
13.0
14.0
15.0
17.0
18.5
18.5
20.5
20.5
23.0
27.0
27.0
30.5
33.5
33.5
37.5
42.0
47.0
53.0
61.0
68.0
79.0
84.0
94.0
103.0
11.0
11.0
13.0
13.0
13.0
15.0
15.0
13.0
17.0
20.5
24.0
24.0
28.0
24.0
31.0
35.0
39.5
44.5
55.0
63.0
74.0
78.0
88.0
96.0
21.0
21.0
23.0
25.0
27.8
27.8
32.0
32.0
32.0
38.5
38.5
43.0
48.0
48.0
52.0
56.0
59.0
67.5
80.0
85.0
90.0
108.0
117.0
127.0
24.0
24.0
26.0
29.0
31.8
31.8
36.5
36.5
36.5
44.0
44.0
48.5
53.0
53.0
58.0
64.0
67.0
77.0
92.0
98.0
113.0
122.0
131.0
148.0
5/8”
5/8”
3/4”
3/4”
3/4”
1”
1”
3/4”
1”
1”
1-1/4”
1-1/4”
1-1/2”
1-1/4”
1-1/2”
2”
2”
2”
2-1/2”
3”
3-1/4”
3-1/2”
4"
41/2"
25.0
25.0
22.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
25.0
25.0
25.0
25.0
25.0
25.0
8.0
10.0
11.0
12.5
13.5
13.5
18.5
18.5
20.5
23.5
23.5
27.0
30.5
30.5
34.0
37.5
41.5
46.5
52.5
60.5
67.5
78.5
84.0
93.0
13.0
14.0
15.0
16.5
18.5
18.5
20.0
20.0
23.0
26.5
26.5
30.0
33.5
33.5
37.0
41.0
46.0
52.0
60.0
67.0
78.0
83.0
93.0
102.0
INSTALLATION INSTRUCTIONS:• Pass the compression nut (Pt.1), Washer No.
1(Pt.3) in succession order over the cable before commencing to strip the cable.
• Remove the outer sheath to the desired length depending on the length of leads required. Pass the rubber ring (Pt.4) over the armouring upto the outer sheath.
• Pass the 2nd washer (Pt.5) over the armouring and splay out the armour wire one by one and then cut the armour wires according to the sizes of washer. Pass the third washer (Pt.6). File the sharp edges of armour wires and bend them so that the armour wires are now secure between the two washers.
• Push the assembly through gland body (Pt.2) and tighten the compression nut. While doing so the rubber ring will expand in radial direction and will grip the cable. This will also ensure dust proof entry of the cable.
A-1
B-1
D-3
L-9
M
L-10
FU
NC
TIO
NA
L D
ES
IGN
D Across Corner
D-3
E
GLAND REF. E D-3 D-3A D L-9 L-10 MRUBBER REF. A-1 B-1 C-1
SIBG-1216
SIBG-1616
SIBG-1619
SIBG-2119
SIBG-2125
SIBG-2925
SIBG-2932
SIBG-2938
SIBG-3632
SIBG-3638
SIBG-4238
SIBG-4251
SIBG-5451
SIBG-5463
SIBG-6063
SIBG-6675
SIBG-7882
SIBG-8490
SIBG-9210
SIBG-1011
SIBG-1525
12
16
19
19
25.4
25.4
32
38
32
38
38
51
51
63.5
63.5
76
83
90
100
110
125
16
19
19
24
24
33
33
33
41
41
47
47
56
56
64
68
82
91
98
107
118
12
12
15
15
21
21
27
32
26
32
32
44.5
44.5
55
55
66
72
81
91
100
113
25.5
29.5
29.5
36.5
36.5
47
47
47
59
59
71
71
80
80
92
100
116
124
135
146
164
15
15
15
18
18
21
21
21
22.5
22.5
26
26
27
27
31
33
33
30
32
32
32
9
9.5
9.5
9.5
9.5
10
10
10
11
11
12
12
12
12
12
13
14
19
20
25
25
3
3.5
3.5
3.5
3.5
4
4
4
4.5
4.5
5.5
5.5
6
6
6.5
7
8
8
8
9
10
R1212
R1611
R1613
R1615
R2116
R2118
R2120
R2921
R2923
R2925
R2927
R2929
R3631
R3633
R3635
R3637
R4236
R4238
R4240
R4242
R5444
R5446
R5448
R5450
R6053
R6055
R6058
R6060
R6662
R6664
R6668
R7870
R7874
R7877
R8484
R9292
R1100
R1115
12
11
13
15
16
18
20
21
23
25
27
29
31
33
35
37
36
38
40
42
44
46
48
50
53
55
58
60
62
64
68
70
74
77
84
92
100
115
18
20.5
20.5
20.5
26
26
26
35
35
35
35
35
45
45
45
45
52
52
52
52
59
59
59
59
68
68
68
68
72
72
72
88
88
88
97
105
114
127
8
9
9
9
11
11
11
12
12
12
12
12
14
14
14
14
17
17
17
17
18
18
18
18
18
18
18
18
18
18
18
20
20
20
20
20
20
20
Installation Instructions:Remove the outer sheath to the desired length depending on the length of the leads required, and splay out the armour wire one by one and then cut the same according to the size of armour clamping cone. File the sharp edges of the armour wire and fit the gland as per assembly shown sectionally.
Parts1. Skid Washer2. Outer Seal3. Sealing Nut4. Brass Body5. Clamping Ring
6. Armour Clamp7. Inner Seal8. Gland Barrel9. Flat Washer10.Check Nut
C A B E
D
123456789
10
FLANGE TYPE CABLE GLANDSBraco Flange Type Cable Glands are made out of brass castings and are machined accurately to the required sizes. These glands are suitable for armoured calbes and are called mechanical glands hence suitable for outdoor application.
The gland comprises of brass body (flange type oval shape) and plate clamped with galavanised mild steel studs and nuts for clamping the armour. Tapered cone and nut are provided for termination of cable.
The cone and body taper is designed for giving a firm grip to the armour of the cable.
FL 5
FL 4
FL 3
FL 2
FL 1
FL 11
FL 0
FL 00
FL 38
FL 001
FL 002
FL 003
FL 0033
FL 004
FL 005
15.0
19.0
19.5
25.0
31.0
31.0
37.5
37.5
42.0
49.0
53.5
60.0
65.0
75.0
99.0
16.5
19.0
20.5
24.5
30.0
34.0
35.0
38.0
42.0
44.0
52.0
58.0
67.0
76.0
83.0
10.0
13.5
13.0
19.0
25.5
28.0
29.5
29.5
34.5
41.0
46.0
52.0
56.0
65.2
88.0
13.0
13.0
13.0
16.5
15.5
15.0
21.0
20.0
21.5
20.5
21.5
23.0
25.5
22.5
22.5
12.0
15.0
18.5
20.5
24.0
29.5
32.5
34.5
37.0
40.5
43.5
51.0
56.5
66.0
75.0
16.5
19.0
20.5
24.5
30.0
34.0
35.0
38.0
42.0
44.0
52.0
58.0
67.0
76.0
83.0
Code No E(mm) Max Dia Of Cable
Under Armour Dia L
Acceptance Dia
Min Max
DOUBLE COMPRESSION GLANDS ( Flame Proof )
BPF 3/8' 11 21.0 24.0 5/8" 12 8.0 12.0BPF 1/2" 11 21.0 24.0 5/8" 12 8.0 13.0BPF 5/8" 14 23.0 26.0 3/4" 15 11.0 15.0BPF 001 14 25.0 29.0 3/4" 15 12.5 16.5BPF 1" 19 30.0 34.0 1" 15 20.0 23.0BPF-001S 12 21.0 24.0 3/4" 15 8.0 12.5BPF-01S 15 25.0 29.0 3/4" 15 12.5 16.5BPF 01 13 28.0 32.0 3/4" 15 15.0 18.0BPF 01L 15 28.0 32.0 1" 15 15.0 18.0BPF 02 15 32.0 36.5 1" 15 18.0 20.0BPF 02S 14 32.0 36.5 3/4" 15 18.0 20.0BPF 03 18 32.0 36.5 1" 15 20.0 23.0BPF 04 20 38.0 44.0 1" 15 23.0 26.0BPF 04L 24 38.0 44.0 1-1/4" 15 23.0 26.0BPF 05 24 41.0 47.0 1-1/4" 15 26.0 30.0BPF 05L 26 41.0 47.0 1-1/2" 15 26.0 30.0BPF 06 31 47.0 53.0 1-1/2" 15 30.0 33.0BPF 06S 24 47.0 53.0 1-1/4" 15 30.0 33.0BPF 07 32 52.0 58.0 1-1/2" 15 33.0 37.0BPF 08 38 56.0 64.0 2" 15 37.0 41.0BPF 09 39 59.0 67.0 2" 15 41.0 46.0BPF 010 44 67.5 77.0 2" 20 46.0 52.0BPF-010L 50 67.5 77.0 2-1/2" 20 46.0 52.0BPF 011 56 80.0 92.0 2-1/2" 20 52.0 60.0BPF 012 64 85.0 98.0 3" 20 60.0 66.0
Flamerproof Braco Cat.
No. AA/FE
A/C E1
Nipple thread Inch D Above Upto
Cable OD (mm)
Braco Double Compression glands are manufactured out of brass rods/castings and are machined accurately to the required sizes. These are nickel plated to avoid corrosion whilst storage and use.
These glands have two moisture proof seals and may be used under most climatic conditions. These are weather proof and waterproof and when protected by a PVC shroud these can be used under most corrosive conditions. The armour cone and ring gives excellent mechanical and electrical connections.
These glands are as per BS6121 1973 and have ten parts: Brass Body, Armour Clamp and Ring, Gland Barrel sealing nut, two pcp seals, the skid washer check nut and flat washer between the gland barrel and check nut is provided to prevent the drag on outer seal. The detail parts are shown in functional drawing.
These glands are available in various different sizes and are suitable for all cables up to 1000 sq.mm. and control cables up to 61 cores. The entry threads on gland barrel are normally threaded according to IS 1653 (Steel conduits for electrical wiring), however if any special kind of gland or thread is required, the same can be supplied on request.
The gland can also be supplied with any other special plating such as cadmium, tin or pasivated. Also the glands can be supplied made out of aluminium, mild steel or stainless steel.
C A B E
D
123456789
10
Parts1. Skid Washer2. Outer Seal3. Sealing Nut4. Brass Body5. Clamping Ring
6. Armour Clamp7. Inner Seal8. Gland Barrel9. Flat Washer10.Check Nut
Certified by : Certificate No.:
Central Institute of Mining & Fuel Research CIMFR/TC/P/H675
SECTION A-A
L
E
Braco BW Brass cable glands are as per BS 6121 Part 1:1989 and suitable for single wire armoured plastic or rubber sheathed cables. These glands provide mechanical cable retention, and electrical continuity via armour wire termination. The use of these glands is recommended in dry, indoor situations. Shrouds may be used for ingress protection.
BW Type Cable Glands
GLANDSIZE
ENTRY THREAD CABLE ACCEPTANCE DETAIL
DIA.
C
20 S
20 L
25 S
25 L
32 S
32 L
40 S
40 L
50 S
50 L
63 S
63 L
75 S
75 L
90 L
20
20
25
25
32
32
40
40
50
50
63
63
75
75
90
9
9
9
10
10
10
11
11
13
13
14
14
15
15
20
11.60
14.00
19.00
20.00
24.00
26.20
30.00
32.50
40.00
44.00
51.00
55.00
62.00
67.00
79.00
16.00
20.00
24.00
27.00
30.50
33.00
37.00
41.00
47.50
52.60
60.00
66.00
72.00
78.00
90.00
0.9/1.25
0.9/1.25
1.25/1.60
1.25/1.60
1.60/2.00
1.60/2.00
1.60/2.00
1.60/2.00
2.00/2.50
2.00/2.50
2.50
2.50
2.50
2.50
2.50/3.15
21.50
24.20
30.00
30.00
36.50
36.50
44.50
46.50
55.00
59.00
69.00
73.00
83.00
86.30
105.00
24.50
27.30
33.60
34.40
40.00
42.30
50.00
52.00
62.00
66.00
76.00
82.00
94.00
98.00
118.00
LENGTHMINIMUM
E
DIAMAX.
A
DIAMAX.
B
ARMOURDIAMETER
D
ACROSSFLAT
ACROSSCORNER
E
BC A
D
CW Type Cable GlandsBraco CW Brass cable glands are as per BS 6121 Part 1 :1989 and suitable for single wire armoured plastic or rubber sheathed cables. The outer seal grips sheath. These glands provide mechanical cable retention, and electrical continuity via armour wire termination. The use of these glands is recommended in indoor as well as outdoor application because of suitability in most climatic conditions weather proof and water proof.
GLANDSIZE
ENTRY THREAD CABLE ACCEPTANCE DETAIL
DIA.
C
20 S
20 L
25 S
25 L
32 S
32 L
40 S
40 L
50 S
50 L
63 S
63 L
75 S
75 L
90 L
20
20
25
25
32
32
40
40
50
50
63
63
75
75
90
10
10
10
10
10
10
11
11
13
13
14
14
15
15
20
11.60
14.00
19.00
20.00
24.00
26.20
30.00
32.50
40.00
44.00
51.00
55.00
62.00
67.00
79.00
16.00
20.00
24.00
27.00
30.50
33.00
37.00
41.00
47.50
52.60
60.00
66.00
72.00
78.00
90.00
0.9/1.25
0.9/1.25
1.25/1.60
1.25/1.60
1.60/2.00
1.60/2.00
1.60/2.00
1.60/2.00
2.00/2.50
2.00/2.50
2.50
2.50
2.50
2.50
2.50/3.15
22.00
25.40
30.00
33.00
38.00
40.00
44.50
46.50
55.00
59.00
69.00
73.00
83.00
87.60
105.00
25.00
28.50
33.60
37.00
43.00
45.00
50.00
52.00
62.00
66.00
76.00
82.00
94.00
99.00
118.00
LENGTHMINIMUM
E
DIAMAX.
A
DIAMAX.
B
ARMOURDIAMETER
D
ACROSSFLAT
ACROSSCORNER
BC A
E
D
A2 Type GlandsBraco A2 type brass cable glands are as per BS 6121 Part 1:1989 and suitable for unarmoured, plastic or rubber sheathed cables. These glands provide outer seal joint and are suitable for indoor as well as outdoor applications.
C
ENTRY THREAD
16L
20S
20L
25S
25L
32S
32L
40S
40L
50S
50L
63S
63L
75S
75L
90L
GLANDSIZE
DIAMAX.
B
ACROSSFLAT
16
20
20
25
25
32
32
40
40
50
50
63
63
75
75
90
12
12
12
15
15
15
15
20
20
20
20
20
20
20
20
20
E
3.50 - 9.00
8.00 - 11.70
11.00 - 14.00
12.00 - 17.00
13.00 - 20.70
16.50 - 23.00
19.00 - 26.30
23.00 - 29.00
25.00 - 33.00
31.50 - 38.20
36.50 - 44.00
42.50 - 50.00
48.00 - 56.00
54.50 - 62.00
60.50 - 68.00
66.00 - 77.00
21.00
22.00
24.00
27.00
30.00
37.00
41.00
45.00
46.00
58.00
62.00
69.00
73.00
82.00
88.00
103.00
24.00
25.00
26.60
30.50
33.30
41.00
45.50
50.00
51.00
64.00
69.00
76.00
81.00
91.00
97.00
114.00
LENGTHMINIMUM
DIA. ACROSSCORNER
G
H
Braco E1W type brass glands are as per BS 6121 part I :1989 suitable for indoor as well as outdoor applications. These glands are suitable for all types of SWA cable, providing environmental seal on both the cable inner and outer sheaths. The glands also provide mechanical cable retention and electrical continuity via armour wire termination.
GLANDSIZE
ENTRY THREAD CABLE ACCEPTANCE DETAIL
DIA.
C
20 S
20 L
25 S
25 L
32 S
32 L
40 S
40 L
50 S
50 L
63 S
63 L
75 S
75 L
90 L
20
20
25
25
32
32
40
40
50
50
63
63
75
75
90
10
10
10
10
10
10
15
15
15
15
15
15
17
17
20
8.00 - 11.80
11.00 - 14.00
12.00 - 17.00
13.00 - 20.30
17.00 - 24.00
19.00- 26.20
23.00 - 30.00
25.00 - 32.20
31.50 - 38.20
36.50 - 44.00
42.50 - 50.00
49.10 - 56.00
54.50 - 62.00
60.50 - 68.00
66.00 - 79.00
12.90 - 17.20
15.50 - 20.80
17.50 - 24.00
24.00 - 27.20
25.00 - 31.00
26.70 - 34.00
31.00 - 38.50
33.00 - 40.50
39.40 - 46.80
45.70 - 53.20
52.10 - 59.00
58.40 - 66.00
64.80 - 72.00
71.10 - 78.00
77.00 - 90.00
0.90/1.25
0.90/1.25
1.25/1.60
1.25/1.60
1.60/2.00
1.60/2.00
1.60/2.00
1.60/2.00
2.00/2.50
2.00/2.50
2.50
2.50
2.50
2.50
2.50/3.15
24.00
27.70
31.50
35.00
43.00
43.00
51.50
51.50
58.50
66.00
72.00
80.00
86.50
94.00
106.00
27.00
31.00
35.00
39.00
47.50
47.50
57.00
57.00
65.00
73.00
80.00
89.00
97.00
105.00
118.00
LENGTHMINIMUM
E
DIAMAX.
A
DIAMAX.
B
ARMOURDIAMETER
D
ACROSSFLAT
ACROSSCORNER
BRACO E1W TYPE GLANDS
ED
C A B
C B
E
PVC SHROUDSBraco black Polyvinyl chloride PVC shrouds are used for fitting over cable glands where additional protection against generous weather conditions and corrosion is required. They provide an effective seal onto both gland and cable oversheath as well as fast and simple installation. PVC shrouds also enhance the IP rating of a termination.
These shrouds are use to minimize the risk of dirt or foreign substances gathering on the cable gland body and or point of cable to gland interface.
DIA A DIA B
Braco earth tags are made out of brass sheets and punched to the required sizes and are suitable for all sizes of cable glands. Electrical continuity is normally achieved via the screwed entry into metal boxes. For clearance Hole entry situations it is essential to obtain direct metal-to-metal contact between the gland, earth tag and the enclosure. These are used to ensure earth continuity between the gland and the equipment.
Earth Tags
CatNo.
Dia A(mm)
Dia B(bolt Hole)
Thickness(mm)
Short CircuitRating KA
ET -20
ET -25
ET -32
ET -40
ET -50
ET -63
ET -75
20.3
25.8
32.4
40.4
51.2
63.9
76.6
6.7
6.7
12.4
13.2
13.2
13.2
13.2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
4.4
4.0
6.2
9.8
11.4
12.0
14.3
DI A A
DI A B
Braco gland kits contain all that is necessary for terminating a cable Gland(s), Earth tag(s), locknut(s) and shroud(s). Since the kits are ready to use hence are convenient and help to keep all parts for each termination together. The kits are easier to stock than loose pieces.
Kits
TAILOR MADETAILOR MADETAILOR MADETAILOR MADE
Nominal Area2mm
Aluminium Stranded Wire Dia with Equivalent solid cross section
Cable size
Dia. of Cond.
Solid CrossSec. Dia.
4
4.5
6
6.75
10
16
25
35
50
70
95
120150
185240
300400
5006258001000
1/2.247/.851/2.367/.921/2.87/1.061/2.97/1.121/3.557/1.351/4.57/1.73/37/2.2419/1.323/3.53/3.667/2.519/1.57/2.87/319/1.87/3.17/3.47/3.657/3.7819/2.247/4.177/4.3919/2.537/1.837/2.0619/337/2.2437/2.537/361/2.2461/2.561/391/2.3691/2.6591/391/2.3591/3.75
2.242.552.362.762.83.182.93.363.554.084.55.16.466.726.67.27.97.57.58.4999.310.210.9811.3411.212.5113.1712.512.614.421515.6817.52120.1622.5272629.153336.941.5
2.242.242.362.362.82.82.92.93.553.64.54.55.25.85.85.86.56.56.57.488899.7109.61111.510.910.912.41313.515.317.517.519.522.522.525.228.231.935.5
0.0010.0015-0.002-0.0030.003--0.0045--0.007--0.010.0145-0.0225-0.030.04--0.06-0.0750.1-0.12-0.15-0.20-0.25-0.3-0.4-0.50.6-0.750.851.0
1/.0361/.0441/.044093/.0291/.05513/.0361/.0641/.07093/.04177/.0297/.03351/.08827/.0367/.04171/.11027/.0447/.0527/.05517/.0647/.066919/.04419/.0527/.08827/.098419/.06419/.070919/.07219/.08319/.088237/.06419/.098437/.07237/.081137/.08337/.088237/.09337/.098437/.10361/.088261/.09361/.098461/.10391/.09361/.118191/.103127/.093127/.103
1/.9141/1.121/1.123/.7371/1.403/.9141/1.631/1.803/1.067/.7377/.8501/2.247/.9147/1.061/2.807/1.127/1.327/1.407/1.637/1.7019/.1.1219/1.327/2.247/2.5019/1.6319/1.8019/1.8319/2.1119/2.2437/1.6319/2.5037/1.8337/2.0637/2.1137/2.2437/2.3637/2.5037/2.6261/2.2461/2.3661/2.5061/2.6291/2.3661/3.0091/2.62127/2.36127/2.62
0.0360.0440.0440.0620.0550.0780.0640.0710.0900.0870.1000.0880.1080.1250.1100.1320.1560.1650.1920.2000.2200.2600.2650.2950.3200.3540.3600.4150.4410.4480.4920.5040.5680.5810.6170.6510.6890.7210.7940.8370.8860.9271.0231.0631.1331.2091.339
0.911.121.121.591.401.971.631.802.282.212.552.242.743.182.803.353.964.204.885.105.596.606.727.508.139.009.1410.511.211.412.512.814.4214.815.6816.517.518.320.1521.322.523.526.027.028.830.734.0
--1.0-1.5--2.52.5-4.04.0-6.06.0--10-16--2535-50--70-95-120-150-185-240-300--400---
Solid and Stranded Conductors Annealed CopperNominal
AreaStranding and Wire Diameter
Appx. overall(Eqvt.) Dia.
2Inch 2mm Inch mm Inch mm
AWG(B7S)
Conversion table for the most important foreign wire gauges to metric units
NBSInchesSWG
Area2mm
Nominal2Inch
Cond. Dia.mm
-8--7-6--5--4--3--2--1--1/0--2/0--3/0-4/0---------
10--9-8--7-6--5--43-2--11/0-2/0--3/04/0-5/0-6/07/0-------
--7/.052”----7/.064”---19/.044”--19/.052”-----19/.064”-----19/.083”--------37/.072”37/.083”37/.103”61/.093”61/.103”91/.103”127/.103”
--0.00145----0.0225---0.03--0.04-----0.06-----0.1--------0.150.20.30.40.50.751.0
8.308.379.3510.5110.5512.9713.3014.5215.7016.7718.6819.3521.1522.7725.8126.6727.2732.1833.6338.6038.7142.4145.6053.1953.4861.3664.5267.4370.1281.0785.394.56107.2109.1126.796.77129.03193.55258.06322.58483.87645.16
3.33.34.03.73.74.14.14.94.54.64.95.65.25.46.65.85.96.46.57.08.17.47.68.28.38.810.59.39.510.210.411.011.711.812.712.814.818.321.323.628.834.0
AWG(B7S)
Conversion table for the most important foreign wire gauges to metric units
NBSInchesSWG
Area2mm
Nominal2Inch
Cond. Dia.mm
28-27-26-25--24-23-22-2120---19--18-17--16-15---1413----1211--10--9-
-29-28-27-2625-24-23-22--21---2019---18--17---16--15-14--13--12--11
------------------1/.036”3/.029”----1/.044”--3/.029”---1/.064”3/.036”----7/.029”----7/.36”--7/.044”--
------------------0.0010.001----0.0015--0.002---0.0030.003----0.0045----0.007--0.01--
0.080.090.100.110.130.140.160.160.200.200.250.260.290.330.400.410.520.520.650.650.650.660.810.820.971.041.171.291.311.591.651.941.942.082.082.622.632.903.243.314.174.294.525.265.486.456.636.82
0.30.40.40.40.40.40.50.50.50.50.60.60.60.60.70.70.80.80.91.10.90.91.01.01.11.21.21.61.31.41.51.42.01.61.61.81.82.22.02.12.32.32.72.62.63.42.92.9
Area2mm
Cond’ Dia’ mm
MCM
250
300
350
400
450
500
550
600
650
700
750
800
850
900
1000
127
152
177
203
228
253
279
304
329
355
380
405
431
456
507
14.6
16.0
17.3
18.5
19.6
20.7
21.7
22.7
23.6
24.5
25.4
26.2
27.0
27.8
29.3
Area2mm
Nominal2Inch
No. and Dia.of strands NBS
Conversion table for the most important foreign wire gauges to metric units
Cond’Dia’ mm
14/.0076”
23/.0076”
40/.0076”
70/.0076”
110/.0076”
162/.0076”
0.0006
0.001
0.0017
0.003
0.0048
0.007
0.39
0.65
1.10
1.94
3.10
4.52
0.9
1.2
1.5
2
2.3
3.1
*Applies only to Multistrand Conductors ACC, to ASTM Stranding Class A,Multistrand construction specified in VDE 0250 table
1 MCM - 1000 CM21 Cm - 1 CIRCULAR MIL = 0.000507 mm
1 CIRCULAR NIL = AREA OF A CIRCLE1 MIL IN DIA’
NominalArea
2In
Copper Cable Stranded and Multistrand Wire with Equivalent solid sectionDiameter & Bare Conductor Diameter
NominalArea
2mm
Cable size
2In
Diam’ ofCond’mm
Solid CrossSect.
Dia. mm.0.0025
0.003
0.004
0.0045
0.015
0.023
0.039
0.065
0.100
0.150
0.175
0.185
0.200
0.230
0.288
0.350
0.420
0.620
40/.0076
27/.0118
70/.0076
45/.0118
144/.0118
91/.018
127/.020
248/.018
416/.018
610/.018
550/.020
427/.0236
810/.018
650/.020
525/.0236
665/.0236
760/.0236
1325/.020
1925/.026
1.6
1.8
2.3
2.6
4.2
5.1
6.5
8.5
12.5
15.3
15.6
16.5
16.2
16.2
18.5
20.3
21.8
22.5
29.5
1.3
1.5
1.7
1.9
3.6
4.54
5.7
7.4
9.2
11.3
12.0
12.4
13.0
13.0
13.8
15.4
16.5
18.5
22.4
1.5
2
2.5
3
10
15
25
42
70
100
112
120
133
150
185
225
270
400
Decimal MillimetersFraction
1/641/323/641/165/643/327/641/89/645/3211/643/1613/647/3215/641/417/649/3219/645/1621/6411/3223/643/825/6413/3227/647/1629/6415/3231/64½33/6417/3235/649/1637/6419/3239/64
0.0150.0310.0460.0620.0780.0930.1090.1250.1400.1560.1710.1870.2030.2180.2340.2500.2650.2810.2960.3120.3280.3430.3590.3750.3900.4060.4210.4370.4530.4680.4840.5000.5150.5310.5460.5620.5780.5930.609
0.40.81.21.62.02.42.83.23.64.04.44.85.25.66.06.36.77.17.57.98.38.79.19.59.910.310.711.111.511.912.312.713.113.513.914.314.715.115.5
Equivalents of an inch
Area2mm
Cond. Dia. mmMCM
Equivalents of an inch
5/841/6421/3243/6411/1645/6423/3247/643/449/6425/3251/6413/1653/6427/3255/647/857/6429/3259/6415/1661/6431/3263/641
0.6250.6400.6560.6710.6870.7030.7180.7340.7500.7650.7810.7960.8120.8280.8430.8590.8750.8900.9060.9210.9370.9530.9680.9841.000
15.916.316.717.117.517.918.318.619.019.419.820.220.621.021.421.822.222.623.023.423.824.224.625.025.4
Nominal Area2mm
Copper Stranded Multistrand Wire sizes in mm with Equivalent solid cross sectionDiameter & Bare Conductor Diameter
Cable sizemm
Dia. of Cond.
Solid CrossSec. Dia.
1.5
2.5
4
6
10
1516
25
35
42
1/1.387/.5221/.330/.25189/.11/1.787/.6735/.350/.25315/.11/2.2619/.5256/.3511/.11/2.767/1.0519/.6485/.3756/.11/3.557/1.3519/.849/.5180/.41197/.191/.4571/4.527/1.737/.7549/.65127/.42058/.17/2.1337/.984/.62200/.4796/.23185/.119/1.5337/1.1133/.56285/.41115/.24459/.1248/.457
1.381.61.71.61.91.782.02.22.12.22.262.62.832.763.23.23.53.73.554.14.34.65.04.55.14.525.15.35.466.86.46.87.77.57.68.37.68.38.78.7910.28.5
1.381.381.381.381.381.781.81.81.81.82.262.262.262.262.762.82.82.82.83.63.63.63.63.63.64.44.54.54.54.54.54.55.75.75.75.75.75.76.76.76.76.76.76.77.4
Nominal Area2mm
Copper Stranded Multistrand Wire sizes in mm with Equivalent solid cross sectionDiameter & Bare Conductor Diameter
Cable sizemm
Dia. of Cond.
Solid CrossSec. Dia.
50
64.570
95
100112120
133
150
185240270300
400
19/1.8361/1133/.69400/.41591/.2416/.45719/2.2461/1.2189/.69560/.419/2.5261/1.4259/.69485/.51936/.25610/.457550/.537/2.0361/1.6336/.67614/.52445/.25810/.457659/.537/2.26392/.69765/.537/2.6261/2.361325/.561/2.5790/.691530/.51925/.5
9.29.710.41110.912.511.211.612.712.812.613.514.514.914.915.315.614.215.516.41616.416.216.215.81819.218.421.322.522.5252729.5
8888889.29.59.59.5111111111111.31212.412.412.412.412.4131313.813.813.815.417.518.520202022.4
BRASS GLANDSBRASS GLANDSBRASS GLANDS
Braco Corrosion Inhabiting Compound is recommended for crimping connections. It is suggested where conditions are particularly aggressive such as chemical or salt-laden atmospheres or where inspection and cleaning are not regular.
Braco Corrosion Inhabiting Compound is mixture of Grey Lithium based grease with abrasive particles and suspended Zinc particles, which assist in jointing because as metal flows under pressure the abrasive particles cause small area of cold welding :
• Corrosion Inhibitor does not affect the electrical properties of the compression joint.
• It is non-corrosive to aluminium, copper, steel, tin, zinc and combination of thes metals.
• It does not deteriorate on exposure to a tmosphere a t conductor operat ing temperature.
• It has good sealing properties against moisture and contaminating substances in the atmosphere It has high temperature drop point.
The mixture contains :1. Grey Lithium based grease 85%2. Zinc Chromate 5%3. Titanium Dioxide 10%
At 700 Amp atAmbient Temp.
After 10 days 6.16mVo3.1mV 5.35mV at 90 c
After 1/2 hour ageing0 ndat 200 C after 2 test
Joint withoutCompound
4.42 mV
5.70 mV
7.06 mV
Joint with BracoCompound
2.65 mV
2.97 mV
3.55 mV
Joint with ImportedCompound
3.85 mV
4.75 mV
5.56 mV
Specification
Test Report
The test carried out on 200 mm conductor joined with Aluminium lugs 95 Sq. mm. The test results found in terms of mV drop compared to joint with nonuse of compound, joint with Braco Compound and joint with imported compound
CORROSION INHABITING COMPOUND
BRASS GLANDS
INTRODUCTION OF BRACO CABLE GLANDS
FUNCTIONS OF CABLE GLANDS²
²
²
²
²
²
SELECTION GUIDELINES
Braco Cable Glands are mechanical cable entry devices, which are constructed from metallic materials and are used throughout all industries in conjunction with cable and wiring used in the electrical control panels, instrumentation and automation systems.
Cable Glands may be used on all types of electrical power, control, instrumentation, data and telecommunications cables. They are used as a sealing and terminating device to ensure that the characteristics of the enclosure which the cable enters can be maintained adequately.
Cable Glands may provide environmental protection by sealing on the outer cable sheath, excluding dust and moisture from the electrical or instrument enclosure.
Cable Glands may facilitate earth continuity in the case of armoured cable when the cablegland has a metallic construction.
Cable Glands may provide a holding force on the cable to ensure adequate levels of cablepull out resistance.
Cable Glands may provide additional sealing on the part of the cable entering the enclosure, when a high degree of ingress protection is required.
. Cable Glands may provide additional environmental sealing at the cable entry point,maintaining the ingress protection rating of the enclosure with the selection of applicableaccessories dedicated to performing this function.
When used in hazardous areas they are required to maintain the level of protection of theequipment to which they are attached.
There are many factors to consider when selecting cable glands for industrial installations. Neglecting to pay due attention to some of these factors may cause unnecessary anxiety at a future point in time when the equipment and cables have been delivered on site, but for example the cable glands have either been forgotten to be ordered or it is discovered that they are the incorrect type or size at the very point when they are needed the most. Good advice would be to allocated some value added planning and preparation time to the subject of cable gland selection so as to avoid the great inconvenience which is likely to occur at a critical point in time. In the event that a user or contractor is in possession of a cable schedule that requires a cable gland selection and sizing process to be carried out Braco products would be blissful to assist in carrying out this process.
While selecting cable glands the following aspects shall be carefully considered:
• Identify the type of cable to be used.• Check the construction, size and material properties of the cable.
If the cable is armoured, verify the following:
²
²
²
²
²
²
²
²
²
²
²
²
²
Check the type and material of the cable armour.
Check the short circuit fault current rating of the cable armour.
Check the actual diameter of the inner bedding.
Check the actual diameter of the lead covering.
Check the actual size of the overall cable diameter.
Check the size and type of armour or braid.
Check any special environmental requirements in relation to corrosion protection.
Check whether any protective plating is required to be applied on the cable gland.
Check the type and size of the cable entry hole in the matching electrical equipment.
Check whether an entry thread seal is required.
Check whether fixing accessories such as locknuts and serrated washers are required.
Check whether earth tags are required.
Check whether shrouds tags are required.
Though the information presented in Gland Selection Chart is intended to assist users to ensure that the correct cable gland is selected. It is the responsibility of the user to ensure that the cable gland selected is of the correct size and type to suit the type of cable being terminated.
While terminating cables and wires during the process of installation of electrical equipment this should be done by qualified and competent personnel in line with good engineering practice, observing safe electrical practices. It is also important that the correct cable entry device or cable gland is also important that the correct cable entry device or cable glands is selected to suit the cable being used. For instances using normal unarmoured cables, the cable would usually be fed through a cable entry device that has a sealing ring activated onto the cable outer sheath. The choice of cable glands to suit this unarmoured cable may need to take into account any vulnerability of the cable, may need to take into account any vulnerability of the cable, which may be especially critical if the cable is an instrument cable. Two factors which could affect the long term cable performance are the type and design of the cable gland sealing function, and the possibility of this being inadvertently or otherwise over tightened onto the cable sheath.