Page 2: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Maximum achieved with fittings

efficiencyaccurate

Braco overload

products are also designed to take

www.bracoworldwide.comWe manufacture finest quality cable

glands and terminals that are designed

to meet customer requirements. We

understand that quality is very important

in an electrical system. Our products

undergo stringent quality inspections, at

various stages in order to maintain the

required quality standards. We believe

in delivering superior products and

unparallel service at competitive prices.

Our cable glands and terminals are

widely used in the field of power

generation & distribution. Braco

products are used in control panels,

switch gears, transformers, circuit

breakers and various other applications.

Braco Electricals (India) Pvt. Ltd. is

committed to timely deliveries that help

clients complete their respective

projects, on time.

At Braco, we always strive to make

products that are highly efficient in

keeping wastages to a bare minimum.

Page 3: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

PROFILE

The year 1977 saw the emergence of Braco products in the Indian Electrical

Market. For the first time, Braco products started the manufacture of cable

glands, under the supervision and guidance of talented and qualified

electrical engineer Shri Ramesh Sobhani.

Braco brand fired up the imagination of top class purchaser of electrical

products like Elecon Engineering Company Limited, who became our first

patron.

Braco products gained reputation and acquired the position of a market

leader in the field of manufacturing and designing of Cable Glands. The

products were in par with international standards. These Cable Glands were

made in all sizes, specifications and designs such as Single Compression

type, SIBG type, Double Compression type, Weather Proof & Flame Proof,

Flange type etc., using materials such as brass for industrial use, aluminum

and stainless-steel for under water cabling.

Due to emergence of grey market in this field, Braco Electricals acquired the

Braco brand under license for its exports and launched the manufacture of

Terminals, Connectors

and other related accessories which created tremendous demand in the

overseas market and thereby it became a major exporter of terminals and

connectors.

Today, Braco is renowned for its superior quality products that minimize

wastage and maximize efficiency.

Page 4: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

OUR MISSION

Braco Electricals (India)Pvt.Ltd. will be the preferred choice for providing

knowledge based quality solutions through pioneering efforts to meet

changing market demands and exceed customers expectations .

Braco Electricals (India) Pvt. Ltd. pioneering position has been strengthened by its unique ability to thrive in

a business environments where technologies are changing with lightening speed on account of intelligent

planning and able technocrats.

While every effort has been taken to ensure that the information as contained & printed in this Catalogue is

correct, yet the company will not accept or cannot be held legally responsible for any claims whatsoever for

any inaccuracy, error or omission which might have crept inadvertantly.

In view of the fast technological improvements in our product the company reserve its right to modify any

part of our product as described in this Catalogue.

At Braco

At Braco Pioneering Means Global Recognisation

At Braco Pioneering Means Sustend Growth.

At Braco Pioneering Means Sastisfied Customer

At Braco Pioneering Means Motivated Bracovites

At Braco Pioneering Means Leaveraging Knowledge

At Braco Pioneering Means Wealth Creation

Pioneering Means Market Leader

Page 5: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Brass: An alloy metal comprising 70% Copper and 30% Zinc. Excellent

cold forming property.

Aluminium: Low in weight. Strong in relation to its weight. Good

conductivity, around 60% of that of copper.

Easy to work.

Copper: High conductivity. High corrosion resistance. Good deformation

properties. Good jointing abilit.

FIELD OF APPLICATION

• Control panels, Switchgears, Transformers, Circuit breakers

• Electricity power generation and Distribution Industries

• Electronic Industries

• Railways

• Steel & Fertilizers Industries • Cement & Textile Industries

• Mining Industries

• Sugar Industries

• Defense Industries

• Shipping Industries

• Aeronautic Industries

• Satellite & Communication

Industries

• Automobile Industries

• Chemical Projects

• Domestics

Braco products are used in

Page 6: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

INDEX

AT Aluminium Crimping Terminals

AT-XL

ILA

WPA

ATB

BTZ

GS

BC

BPW

FL

CW

BW

A2

Aluminium Tube Terminals For Al-xlpe Conductors

Aluminium Crimping Connector

Aluminium Crimping Reducer Terminals For Aluminium Conductor

Long Barrel Aluminium Crimping Terminals For Aluminium Conductor

Aluminium Alloy Tubular Bimetallic Terminals

Corrosion Inhabiting Compound

onGland Selecti Chart

Single Compression Glands( Commercial Series )

Double Compression Glands( Weather Proof )

Flange Type Cable Glands

BW Type Glands

CW Type Glands

A2 Type Glands

Earth TagsET

PVC Shrouds

Kits

Tailor Made

AT

ATT

PVC

KITS

TM

PAGE NO. PRODUCT SERIES TITLE

Double Hole Aluminium Crimping Terminals For Aluminium Conductors

PAGE NO. PRODUCT SERIES TITLE

SIBG

BPFW

Single Compression Glands( SIBG Series )

E1W E1W Type Glands

Double Compression Glands( Flame Proof )

R, RI, RD

P, PI, PD

F, FI, FD

RF, RFI, RFD

OC

BSS

WB

Copper Crimping Reducer Terminals for Aluminium Conductor

CT

CA

CT

CT

CT

ILC

ILCI

WPC

BMT

BMP

Copper Crimping Terminals With Inspected Hole (light duty)

Copper Crimping Terminals With Inspected Hole For Copper Conductor (heavy duty)

Extended Palm Blanks Copper Crimping Terminals Ends For Copper Conductors

Copper Crimping Terminals For Copper Conductors (long barrel)

Copper Tube In-line Connectors

Copper Tube In-line Connector -Insulated

Bi-Metallic Terminals

Bi-Metallic Pin Terminals

Copper Crimping Ring Terminals (non-insulated and insulated)

Copper Ring Tongue Fork Terminals

Copper Crimping Pin Terminals (non-insulated and insulated)

Copper Crimping Fork Terminals (non-insulated and insulated)

Open Close Soldering Type Copper Ring Terminals

ESCopper Crimping End Sealing Ferrules

Copper Crimping End Sealing Insulated Ferrules

CTSSoldering Type Copper Terminals (light duty)

Soldering Type Copper Terminals (heavy duty)

Soldering Type Copper Weak Back Ferrules

SNP Snap on Terminals

Copper Crimping Terminals For Aluminium Conductor (light duty)

PAGE NO. PRODUCT SERIES TITLE

ESI

PAGE NO. PRODUCT SERIES TITLE

CTCopper Crimping Terminals DIN 46235

Page 7: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Cable Glands and Terminals COPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALS

Page 8: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

2.5

4-6

10

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

6

8

8

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

2.3

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

3.5

4.3

4.3

3.2

3.7

3.7

4.2

5.2

5.2

6.4

5.2

6.4

8.2

6.4

8.2

10.2

10.2

12.7

4.2

5.2

4.2

5.2

5.2

5.2

6.4

8.2

5.2

6.4

6.4

8.2

9.7

8.2

10.2

8.2

10.2

12.7

4.2

8.2

12.7

12.7

16.0

16.0

16.0

18.0

18.0

22.0

22.0

22.0

25.0

25.0

25.0

29.0

29.0

17.0

17.0

19.0

19.0

22.0

20.0

20.0

20.0

22.0

22.0

25.5

25.5

25.5

30.0

30.0

30.0

30.0

30.0

22.0

22.0

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

14

14

14

14

14

14

14

14

14

14

14

14

14

14

14

14

14

14

16

16

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

3.9

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

6.3

6.3

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

4.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.4

6.8

6.8

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

15

15

15

15

15

15

15

15

15

15

15

15

15

15

15

15

15

15

17

17

6.5

6.5

8.0

8.0

8.0

10.0

10.0

12.0

12.0

12.0

16.0

16.0

16.0

18.0

18.0

8.0

8.0

10.0

10.0

8.0

12.0

12.0

12.0

12.0

12.0

14.0

14.0

14.0

16.0

16.0

18.0

18.0

18.0

10.0

18.0

R - 107

R - 008

R - 108

R - 009

R - 010

R - 109

R - 011

R - 110

R - 012

R - 013

R - 111

R - 014

R - 015

R - 151

R - 047

R - 155

R - 050

R - 112

R - 016

R - 157

R - 113

R - 017

R - 018

R - 114

R - 019

R - 115

R - 020

R - 021

R - 116

R - 022

R - 117

R - 023

R - 024

R - 118

R - 025

RI - 068

RI - 069

RI - 070

RI - 071

RI - 072

RI - 073

RI - 074

RI - 075

RI - 076

RI - 077

RI - 078

RI - 079

RI - 080

RI - 081

RI - 082

RI - 083

RI - 084

RI - 085

RI - 086

RI - 087

RI - 088

RI - 089

RI - 090

RI - 091

RI - 092

RI - 093

RI - 094

RI - 095

RI - 096

RI - 097

RI - 098

RI - 099

RI - 100

RI - 389

RI - 395

RD - 451

RD - 452

RD - 453

RD - 454

RD - 455

RD - 456

RD - 457

RD - 458

RD - 459

RD - 460

RD - 461

RD - 462

RD - 463

RD - 464

RD - 465

RD - 466

RD - 467

RD - 468

RD - 469

RD - 470

RD - 471

RD - 472

RD - 473

RD - 474

RD - 475

RD - 476

RD - 477

RD - 478

RD - 479

RD - 480

RD - 481

RD - 482

RD - 483

RD - 484

RD - 485

SizeSq. mm

Code No. Code No. Code No.Dimensions

BAE JCA-1 J-1J-1

D

Wire barrel

Bell mouthed for easy cable entry

Colour coded bell mouthed PVC insulation

Bell mouthed copper sleeve

High conductivity copper tinned for

corrosion resistance

Bell mouthed chamfered lead-in

Braco Ring Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanicals vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction. All the terminals are tin plated to avoid oxidization and to achieve maximum corrosion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.

1.5 2.5 4.6

Colour Coding Insulated Terminals:

1.5 1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

2.2

2.6

3.2

3.7

4.2

3.2

3.7

4.2

3.2

4.2

5.2

4.2

4.2

5.2

6.4

6.4

14.0

14.0

14.0

14.0

14.0

13.0

13.0

13.0

16.0

16.0

16.0

14.5

18.0

18.0

18.0

18.0

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

6.0

6.0

6.0

6.0

6.0

6.8

6.8

6.8

8.0

8.0

8.0

7.0

10.0

10.0

10.0

12.0

R - 103

R - 000

R - 001

R - 002

R - 003

R - 153

R - 048

R - 049

R - 104

R - 004

R - 005

R - 154

R - 105

R - 006

R - 007

R - 106

RI - 052

RI - 053

RI - 054

RI - 055

RI - 056

RI - 057

RI - 058

RI - 059

RI - 060

RI - 061

RI - 062

RI - 063

RI - 064

RI - 065

RI - 066

RI - 067

RD - 435

RD - 436

RD - 437

RD - 438

RD - 439

RD - 440

RD - 441

RD - 442

RD - 443

RD - 444

RD - 445

RD - 446

RD - 447

RD - 448

RD - 449

RD - 450

SizeSq. mm

Code No. Code No. Code No.Dimensions

AE JC A-1 J-1J-1D

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

5

B

Material Copper BS: 1897 Finish: Electro Tinned

COPPER CRIMPING RING TERMINALS (NON-INSULATED AND INSULATED)

D

J1C

E

B

J

AJ

CA

B

D

E

Page 9: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

SizeSq. mm Code No.

Dimensions

DE BA JC

35

50

70

95

120

150

6.4

8.2

8.2

10.2

10.2

12.7

8.2

10.2

10.2

10.2

12.7

16.2

10.2

12.7

12.7

16.2

10.2

10.2

12.7

16.2

12.7

16.2

20.3

12.7

16.2

20.3

9.0

9.0

9.0

9.0

9.0

9.0

10.5

10.5

10.5

10.5

10.5

10.5

12.0

12.0

12.0

12.0

13.5

13.5

13.5

13.5

15.0

15.0

15.0

16.5

16.5

16.5

12.6

12.6

12.6

12.6

12.6

12.6

14.1

14.1

14.1

14.1

14.1

14.1

16.0

16.0

16.0

16.0

18.1

18.1

18.1

18.1

20.2

20.2

20.2

23.7

23.7

23.7

16

16

18

18

22

22

18

18

22

24

24

32

22

22

24

24

22

24

24

28

26

32

40

34

34

40

12

12

12

12

12

12

16

16

16

16

16

16

18

18

18

20

20

20

20

20

22

22

22

24

24

24

31

31

36

36

42

42

43

43

43

48

48

54

47

47

48

54

46

50

50

58

52

64

72

66

66

74

R - 133

R - 038

R - 134

R - 039

R - 135

R - 040

R - 136

R - 041

R - 137

R - 138

R - 042

R - 139

R - 140

R - 043

R - 141

R - 142

R - 143

R - 144

R - 044

R - 145

R - 146

R - 147

R - 148

R - 149

R - 045

R - 046

COPPER CRIMPING RING TERMINALS (NON-INSULATED)

SizeSq. mm Code No.

Dimensions

DE BA JC

10

16

10

12

16

18

18

22

22

10

12

12

16

16

16

18

18

22

22

12

12

16

16

16

16

16

18

22

22

5.2

6.4

8.2

8.2

10.2

10.2

12.7

5.2

5.2

6.4

6.4

8.2

9.7

8.2

10.2

10.2

12.7

6.4

8.2

6.4

8.2

10.2

6.4

8.2

10.2

10.2

12.7

8

8

8

8

8

8

8

10

10

10

10

10

10

10

10

10

10

11

11

11

11

11

11

11

11

11

11

4.3

4.3

4.3

4.3

4.3

4.3

4.3

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

5.6

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

7.5

20

23

27

30

30

34

34

24

26

26

30

30

30

33

33

35

35

31

31

30

30

30

33

33

34

42

42

6.3

6.3

6.3

6.3

6.3

6.3

6.3

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

11.1

11.1

11.1

11.1

11.1

11.1

11.1

11.1

11.1

11.1

R - 026

R - 120

R - 121

R - 122

R - 027

R - 123

R - 028

R - 124

R - 125

R - 029

R - 126

R - 030

R - 031

R - 127

R - 032

R - 128

R - 033

R - 156

R - 051

R - 129

R - 034

R - 035

R - 130

R - 036

R - 131

R - 132

R - 037

25

Braco Ring Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanicals vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction. All the terminals are tin plated to avoid oxidization and to achieve maximum corrosion protection.

JC

A

B

D

E

Page 10: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Ring Tongue Fork Terminals are designed to offer maximum efficiency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanical vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction.All the terminals are tin plated to avoid oxidisation and to achieve maximum corrossion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.

Material Copper BS: 1897 Finish: Electro Tinned

1.5 2.5 4.6

Colour Coding Insulated Terminals:

COPPER RING TONGUE FORK TERMINALS

J

1.5

2.5

4-6

10

16

5

5

5

5

5

5

5

5

5

5

5

5

5

6

6

6

6

6

8

8

8

8

10

10

10

10

1.6

1.6

1.6

1.6

1.6

1.6

1.6

1.6

2.3

2.3

2.3

2.3

2.3

3.5

3.5

3.5

3.5

3.5

4.3

4.3

4.3

4.3

5.6

5.6

5.6

5.6

3.1

3.6

3.1

3.6

4.1

4.1

5.1

6.1

3.1

3.6

4.1

5.1

6.1

4.1

4.1

5.1

5.1

6.1

4.1

5.1

6.1

8.1

5.1

6.1

8.1

8.1

14

14

13

13

14

16

18

18

12.7

12.7

16

18

18

17

19

19

22

22

22

22

23

27

24

26

30

33

10

10

10

10

10

10

10

10

10

10

10

10

10

14

14

14

14

14

16

16

16

16

--

--

--

--

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.9

3.9

3.9

3.9

3.9

5.5

5.5

5.5

5.5

5.5

6.3

6.3

6.3

6.3

8.0

8.0

8.0

8.0

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

4.4

4.4

4.4

4.4

4.4

6.4

6.4

6.4

6.4

6.4

6.8

6.8

6.8

6.8

--

--

--

--

10

10

10

10

10

10

10

10

10

10

10

10

10

15

15

15

15

15

17

17

17

17

--

--

--

--

6.0

6.0

6.8

6.8

7.0

8.0

10.0

10.0

6.5

6.5

8.0

10.0

10.0

8.0

10.0

10.0

10.0

12.0

10.0

10.0

12.0

16.0

10.0

12.0

16.0

18.0

RF - 235

RF - 240

RF - 241

RF - 244

RF - 237

RF - 236

RF - 238

RF - 861

RF - 862

RF - 863

RF - 239

RF - 242

RF - 864

RF - 243

RF - 245

RF - 246

RF - 247

RF - 248

RF - 865

RF - 866

RF - 867

RF - 868

RF - 869

RF - 870

RF - 871

RF - 872

RFI - 873

RFI - 874

RFI - 875

RFI - 876

RFI - 877

RFI - 878

RFI - 879

RFI - 880

RFI - 881

RFI - 882

RFI - 883

RFI - 884

RFI - 885

RFI - 886

RFI - 887

RFI - 888

RFI - 889

RFI - 890

RFI - 891

RFI - 892

RFI - 893

RFI - 894

-----

-----

-----

-----

RFD - 899

RFD - 900

RFD - 901

RFD - 902

RFD - 903

RFD - 904

RFD - 905

RFD - 906

RFD - 907

RFD - 908

RFD - 909

RFD - 910

RFD - 911

RFD - 912

RFD - 913

RFD - 914

RFD - 915

RFD - 916

RFD - 917

RFD - 918

RFD - 919

RFD - 920

-----

-----

-----

-----

SizeSq. mm AE BC D

Dimensions

J

Code No. Dim.

J-1

Code No.Dimensions

A-1 J-1

Code No.

DE J

B

AC

J1

Braco Pin Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanical vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed, which means that the terminal can be crimped in either direction

All the terminals are tin plated to avoid oxidisation and to achieve maximum corrossion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.

COPPER CRIMPING PIN TERMINALS (NON-INSULATED AND INSULATED)

SizeSq. mm

Code No. Code No. Code No.Dimensions

BA TYPEJC A-1 J-1J-1D

1.5

2.5

4

6

10

16

25

35

50

70

95

5

5

5

5

6

6

6

6

8

10

11

12

16

18

21

1.6

1.6

2.3

2.3

2.9

3.6

3.6

4.0

4.5

5.8

7.5

9.0

10.5

12.0

13.8

I

II

I

II

I

II

I

I

III

III

III

III

III

III

III

17

17

17

17

20

20

20

20

22

26

31

37

42

45

52

10

10

10

10

14

14

14

14

16

20

3.2

3.2

3.9

3.9

4.9

5.6

5.6

6.0

6.7

8.2

11.1

12.6

14.1

16.0

18.7

3.6

3.6

4.4

4.4

6.4

6.4

6.4

6.4

10

10

10

10

15

15

15

15

1.9

3.1

1.9

3.1

2.7

5.1

2.7

2.7

4.3

5.5

7.0

8.0

9.0

10.0

11.0

P - 9

P - 35

P - 1

P - 2

P - 3

P - 4

P - 5

P - 6

P - 7

P - 8

P - 86

P - 87

P - 88

P - 94

P - 95

PI - 17

PI - 40

PI - 18

PI - 19

PI - 20

PI - 21

PI - 22

PI - 23

PI - 24

PI - 25

PD - 26

PD - 42

PD - 27

PD - 28

PD - 29

PD - 30

PD - 31

PD - 32

Material Copper BS :1897Finish : Electro Tinned

1.5 2.5 4.6

Colour Coding Insulated Terminals:

D

J1

D

J1

B

J

CA

BJ

CA

Page 11: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Fork Terminals are designed to offer max imum ef f ic iency under heavy-duty applications. Therefore these terminals are ideal for use in applications which are subject to continuous mechanical vibrations viz. engines, railways, moving components etc. The terminal barrel is brazed and soft annealed which means that the terminal can be crimped in either directionAll the terminals are tin plated to avoid oxidisation and to achieve maximum corrossion protection. These terminals can be provided with PVC sleeves for protection against electrical shocks and can also be provided with metal reinforced sleeves to maintain a proper grip on conductor insulation.

Material Copper BS: 1897 Finish: Electro Tinned

1.5 2.5 4.6

Colour Coding Insulated Terminals:

COPPER CRIMPING FORK TERMINALS (NON-INSULATED AND INSULATED)

SizeSq. mm

Code No. Code No. Code No.Dimensions

DE JBA A-1 J-1J-1C

1.5

2.5

4-6

10

5

4

5

5

6.2

6

6

8

8

1.6

1.6

2.0

2.3

2.6

3.5

3.5

4.5

4.5

5.1

3.5

3.0

3.5

5.0

3.1

3.5

6.5

8.2

21

13

13

15

21

15

15

27

27

10

10

10

10

10

14

14

16

16

3.2

3.2

2.8

3.9

4.6

5.5

5.5

6.9

6.9

3.6

3.6

3.6

4.4

4.4

6.4

6.4

6.8

6.8

10

10

10

10

10

15

15

17

17

8.0

6.8

6.2

6.5

10.6

6.0

6.0

16.0

16.0

F - 214

F - 249

F - 250

F - 251

F - 280

F - 252

F - 253

F - 254

F - 255

FI - 925

FI - 926

FI - 927

FI - 928

FI - 929

FI - 930

FI - 931

FI - 932

FI - 933

FD - 934

FD - 935

FD - 936

FD - 937

FD - 938

FD - 939

FD - 940

FD - 941

FD - 942

D

C

J

Braco open close terminals are made out of EC grade copper. These terminals ensure completeness and ease of conductor entry so that contact is reliable and have more tensile strength. The terminals are annealed to avoid cracking or breaks and are tin plated to avoid oxidization and to achieve maximum corrossion protection.

Material Copper BS :1897Finish : Electro Tinned

SizeSq. mm

Code No.Dimensions

DE BA JC

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

225

240

300

400

500

625

7

9

9

12

12

15

15

18

24

28

32

34

38

42

44

48

54

62

62

70

4.2

5.2

5.2

6.5

6.5

8.2

8.2

8.2

10.2

10.2

12.7

12.7

12.7

16.2

16.2

16.2

20.3

20.3

20.3

20.3

5

6

6

7

9

11

14

15

18

23

25

29

30

35

40

42

45

54

58

65

1.6

2.3

2.8

3.6

4.4

5.4

7.0

8.0

9.5

11.8

13.5

15.5

16.5

18.5

21.0

22.5

25.0

29.5

32.0

36.0

15

18

20

24

27

32

36

41

50

58

66

73

79

87

92

100

110

125

137

148

3.2

3.9

4.8

5.6

6.4

7.8

10.2

11.2

13.1

15.8

18.7

21.1

22.9

25.7

28.2

30.5

34.0

39.5

42.8

46.8

OC - 71

OC - 72

OC - 73

OC - 74

OC - 75

OC - 76

OC - 77

OC - 78

OC - 79

OC - 80

OC - 81

OC - 82

OC - 83

OC - 84

OC - 85

OC - 86

OC - 87

OC - 88

OC - 89

OC - 90

OPEN CLOSE SOLDERING TYPE COPPER RING TERMINALS

D

EB

J

AC

BJ1

E

A

Page 12: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco End Sealing Ferrules are manufactured from electrolytic copper. These ferrules are used when a perfect connection is needed at the end of a cable. Some cables, especially those with small diameters, may conduct badly in electrical connections without an End Sealing Ferrule. By using these ferrules strands deviation can be avoided and the risk of cable breakage can be reduced. Also these ferrules create a long lasting contact pressure and a large contact surface. Tinning is provided to give better finish, to avoid oxidisation and to achieve maximum corrosion protection.

Material Copper BS: 1997 Finish: Electro Tinned

SizeSq. mm

Code No.Dimensions

A C J

0.5

0.75

1.0

1.5

2.5

4.0

6.0

10

16

1.0-1.1

1.4-1.5

1.6-1.7

1.6-1.7

1.8-1.9

1.8-1.9

2.3-2.4

2.3-2.4

2.8-2.9

2.8-2.9

3.7-3.8

3.7-3.8

3.7-3.8

4.6-4.7

4.6-4.7

4.6-4.7

5.9-6.0

5.9-6.0

5.9-6.0

1.4-1.5

1.8-1.9

2.0-2.1

2.0-2.1

2.2-2.3

2.2-2.3

2.7-2.8

2.7-2.8

3.2-3.3

3.2-3.3

4.1-4.2

4.1-4.2

4.1-4.2

5.0-5.1

5.0-5.1

5.0-5.1

6.3-6.4

6.3-6.4

6.3-6.4

6

6

6

10

7

10

7

12

9

12

10

12

15

12

15

18

12

15

18

ES - 08

ES - 09

ES - 10

ES - 11

ES - 12

ES - 13

ES - 14

ES - 15

ES - 16

ES - 17

ES - 18

ES - 19

ES - 20

ES - 21

ES - 22

ES - 23

ES - 24

ES - 25

ES - 26

COPPER CRIMPING END SEALING FERRULES

J

CA

Braco End Sealing Insulated Ferrules are manufactured from electrolytic copper. These ferrules have dimensions according to DIN 46228 and are used when a perfect connection is needed at the end of a cable. Some cables, especially those with small diameters, may conduct badly in electrical connections without an End Sealing Ferrule. By using these ferrules strands deviation can be avoided and the risk of cable breakage can be reduced. Also these ferrules create a long lasting contact pressure and a large contact surface. Tinning is provided to give better finish, to avoid oxidisation and to achieve maximum corrosion protection.

The Insulation Sleeve is manufactured from PP (Polypropylene). We also offer end terminals with insulation colours according to the most common colour system in the market. The colour of the insulation sleeves characterises the Cross section area of the conductor

Material Copper BS :1997Finish : Electro Tinned

COPPER CRIMPING END SEALING INSULATED FERRULES

SizeSq. mm

Code No.Dimensions

A C J

0.5

0.75

1.0

1.5

2.5

4.0

6.0

10

16

1.0-1.1

1.4-1.5

1.6-1.7

1.6-1.7

1.8-1.9

1.8-1.9

2.3-2.4

2.3-2.4

2.8-2.9

2.8-2.9

3.7-3.8

3.7-3.8

3.7-3.8

4.6-4.7

4.6-4.7

4.6-4.7

5.9-6.0

5.9-6.0

5.9-6.0

1.4-1.5

1.8-1.9

2.0-2.1

2.0-2.1

2.2-2.3

2.2-2.3

2.7-2.8

2.7-2.8

3.2-3.3

3.2-3.3

4.1-4.2

4.1-4.2

4.1-4.2

5.0-5.1

5.0-5.1

5.0-5.1

6.3-6.4

6.3-6.4

6.3-6.4

6

6

6

10

7

10

7

12

9

12

10

12

15

12

15

18

12

15

18

ESI - 08

ESI - 09

ESI - 10

ESI- 11

ESI- 12

ESI- 13

ESI - 14

ESI- 15

ESI- 16

ESI- 17

ESI- 18

ESI- 19

ESI- 20

ESI- 21

ESI- 22

ESI- 23

ESI - 24

ESI - 25

ESI- 26

J-1

12

12

12

16

14

16

14

18

16

18

18

20

23

22

25

28

24

27

30

JA

J1

C

Page 13: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco snap on Terminals are made out of Phosporus bronze These are used in electrical and electronic installations like PCB mounted devices, electronic power relays etc. These can also be provided with insulation.

SNAP ON TERMINALS

0.7

0.25

2

6

71.

B B

15

4

Section on A-A

Section on B-B

2.8

2.5

8368

CAT. NO.

AA

61 9

1.54

1.6.61

17

6

30.

8

8370

CAT. NO.

14

CAT. NO.

8351 8352

CAT. NO.

7.6

16

21

6.6

2.4

3

10

3.62.4Ø

0.4

CAT. NO. CAT. NO.8358 8359

2.6 0.4

4.9

1.1

10

19 2.4

3.6

146.

4

2.4

5.8 6

2

17

1.

2.6

AA

4.2

7.6

15

2.

.7 2

.3 2

23.

04.

8178

CAT. NO.

.67

17

21

01

2.8.50

3.2

.76

.1 6

.82

.44

8347/8348

CAT. NO.

0.8

16

79

21.5

3 4

1

1.5

8369

CAT. NO.

1

7.6

7.6

0 8.

1.6

6.6

16

2.4

2

6.3

2110

3.6

8360/8361

CAT. NO.

515.5

2

103.2

3.2

1.6

8.2

0.9

2.5

73.210

8

24

906.6

5

34

3.

8367

CAT. NO.Sectional Plan

CAT. NO. CAT. NO.8324 8325

142

6.4

2.7Ø

0.25

19

10

3.10.7

3.6Ø

2.4

7.1

0.3

B B

3.1

28.

4

420

31.

8364

CAT. NO.

Section On A-A Section On B-B

7.5

2.3

7.6

163

21

10

.40

6.61.6

1.34.4

8349/8350

CAT. NO.

Page 14: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

CAT. NO.

8197

CAT. NO.

8353

0.8

4.9

2.4

14

2.6 0.4

6.4

1910

2.4

4.4

8477

CAT. NO.

3.2

36.

28.

5.5

2.5

7

.20

5.

143

4.2

3.2

5.2

6.2

1032

32

.4 4.2 3.2 3

4

.0 8 6.4

8

8363/8473

CAT. NO.

0.84.5

8

8

166.4

.21

4

8

8346

A .C T NO.83318241

CAT. NO. CAT. NO.

19

146.

4

10

23. .0 52

.3 1.0 7 3. Ø6

2.7Ø

CAT. NO.

8362

146

4.

2.7Ø

19

10

2

.0 25

3.10.7

.3 6Ø

CAT. NO.

8336

CAT. NO.

8356 8357

CAT. NO.

13.2 2

0.4.3 6Ø

5.4

18

.0 52

01

2. Ø7

1.5

CAT. NO.

8476

CAT. NO.

2.8

6.4Ø

2.8Ø

21

17

10

7.6

0.5

0.7

6.7

3.2

1.6

8347

8366

CAT. NO.

8474

CAT. NO.

3.5

6.9

1.4

450.

81

2.9

8

44.

21.5

10

29

CAT. NO.

8354

2.7

131

5.

0.25

0.4

2.2

5.4

8110

6Ø3.

CAT. NO.

83558365

CAT. NO. CAT. NO.

8475

18

10.

215

.2 3

.2 3

.35 0.56

1.4

4.4.6 7

8

53.

7

11

3.5

ox 1 453 1

7

2 H LE O S 2.8

- 0

3.2

8

R

70. 8 0 83.

8214

CAT. NO.

Page 15: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

SCOPE OF LUGS: The Cable Lugs are used for termination of cables to the equipments and connectors are used to extend the cables. The cable sizes vary as per the electric current requirements. Generally cable sockets/terminals used shall be of E. C. Grade copper. The cable sockets shall be duly tin plated for outer finish and to withstand the corrosion while storage and use.

PROCESS OF MANUFACTURING CABLE LUGS

A) EXTRUSIONS: The cable Lugs & Connectors of various sizes are manufactured out of copper EC Grade wire bars. These wire bars are cut into 3 to 4 parts for melting. These are refined and are casted into round ingots as per required sizes. These ingots under go a process of cutting, which finally turns into the extrusion billets. These billets are drilled as per required I.D. of the internal diameter of tubes. These are further heated in gas fired furnaces to appropriate extrusion temperature. The heated billets are then extruded by hydropneumatic press into the mother tubes of required sizes. Three types of mother tubes are used for copper cable sockets.

B) TUBE DRAW: The copper mother tubes are finally made to required size of copper tubes which varies as per size of cable. The chart show the various sizes of copper tubes used. The dimension 'C' is 0. D. and 'A' is I. D. of Tube required for the particular cable terminals. The process is called tube drawing process. The mother tubes are drawn in draw bench with required T.C. dies of O.D, and plug for required I. D.

During the process the copper undergoes annealing process and each time the tube made to smaller size by swaging machine so that the pipe to be pulled at the beginning of pipe. This swaged pipes are pulled in draw bench every time it passes through small T.C. dies to reduce the diameters and every time these are annealed in heating furnace which gives burning and annealing loss.

PROCESS

C) CABLE LUGS MANUFACTURING: The drawn tubes are finally cut into the pieces in cutting machine to the required length of cable lugs and are chamfered. The cut tubes are finally annealed in annealing furnace and forged to make the plam of socket and in cutting process the front arc and hole is made. The lugs are then marked with required code number and size of cable. After this the lugs are ready for plating.

I.D.

O.D.

50

64

38

50

37.5

40

D) TINNING PROCESS:

The cable lugs are finally acid tinned in plating plant. The tinning process is required for surface finish as well as to avoid corrosion whilst storage and use.

The cable sockets are finally checked and packed in boxes with sizes marked on the box. These boxes are finally packed in master carton for the final dispatch in export worthy packing.

All the process checked at each stage as per the quality assurance plan.

COPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALSCOPPER TERMINALS

Page 16: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco soldering type heavy duty copper terminals are made out of EC grade copper and used where high value of current flow is desired and due to soldering loose terminations are avoided, thereby preventing heating at termination ends. Terminals are tin plated to avoid oxidization and to achieve maximum corrossion protection.

SOLDERING TYPE COPPER TERMINALS (HEAVY DUTY)

AMPS Code No.Dimensions

DE BA JC

15

30

60

100

150

200

300

400

500

300

500

630

9

12

17

21

25

29

36

41

46

49

59

67

5.1

7.1

10.3

11.9

13.5

13.5

16.7

16.7

19.8

18.0

22.0

26.0

10

13

14

19

22

29

32

38

44

44

48

56

4.8

6.4

9.5

11.9

14.3

16.7

20.6

23.8

26.2

26.2

31.7

36.5

24

33

44

55

62

78

86

100

111

111

121

139

6.2

8.0

11.3

13.9

17.1

19.9

24.2

27.8

31.4

34.2

40.9

46.1

BSS - 6

BSS - 7

BSS - 8

BSS - 9

BSS - 10

BSS - 11

BSS - 12

BSS - 13

BSS - 14

BSS - 28

BSS - 29

BSS - 30

Material Copper BS :1977Finish : Electro Tinned

SOLDERING TYPE COPPER TERMINALS (LIGHT DUTY)Braco soldering type copper terminals are made out of EC grade copper and used where high value of current flow is desired and due to soldering loose terminations are avoided, thereby preventing heating at termination ends. Terminals are tin plated to avoid oxidization and to achieve maximum corrossion protection.

AMPS Code No.

Dimensions

DE BA JC

15

30

60

100

150

200

300

400

500

600

800

1000

1000

7

9

14

19

24

28

33

38

43

47

56

66

85

3.9

5.2

8.1

10.9

13.9

16.6

19.0

22.2

25.4

27.8

31.7

38.1

50.0

19

23

36

49

57

66

80

89

105

115

121

152

164

CTS - 01

CTS - 02

CTS - 03

CTS - 04

CTS - 05

CTS - 06

CTS - 07

CTS - 08

CTS - 09

CTS - 10

CTS - 11

CTS - 12

CTS - 95

3.2

5.1

6.4

9.5

9.5

12.7

12.7

15.9

19.0

19.0

23.8

23.8

-

4.8

6.3

9.5

12.7

15.9

19.0

22.2

25.4

28.6

31.8

38.1

44.5

57.3

7

9

14

19

23

27

28

32

38

44

47

56

62

Material Copper BS :1977Finish : Electro Tinned

E

CA

BJ

D

E

CA

BJ

D

Page 17: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Soldering Type Weak Back Ferrules are manufactured out of copper and are used to solder straight through joints. Tinning is provided to give better finish, to avoid oxidisation and to achieve maximum corrossion protection.

6

10

16

25

35

50

70

95

120

150

185

225

240

300

400

500

625

20

25

25

30

35

40

45

50

55

60

65

75

80

85

95

105

115

3

4

5

7

8

9

12

13

15

16

18

20

21

23

27

30

33

WB - 79

WB - 80

WB - 81

WB - 82

WB - 83

WB - 84

WB - 85

WB - 86

WB - 87

WB - 88

WB - 89

WB - 90

WB - 91

WB - 92

WB - 93

WB - 94

WB - 95

SizeSq. mm

Code No.Dimensions

LA TC PG

3.0

4.4

5.5

7.0

8.0

9.5

12.0

13.5

15.5

17.0

18.5

20.5

22.0

24.0

28.5

30.5

34.5

2

2

2

2

2

2

3

3

4

4

4

5

5

5

7

7

8

0.8

0.8

1.0

1.0

1.2

1.2

1.4

1.4

1.6

1.8

2.2

2.2

2.2

2.8

3.1

3.5

4.0

4.6

6.0

7.5

9.0

10.4

11.9

14.8

16.3

18.7

20.6

22.9

24.9

26.4

29.6

34.7

37.5

42.5

SOLDERING TYPE COPPER WEAK BACK FERRULES

Material Copper BS :1997Finish : Electro Tinned

P

L

Braco Copper Tube Crimping Terminals are manufactured from electrolytic copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cables, electrical switching equipments, where vibration is critical.

Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In application subject to vibration, terminals still have to perform a reliable connection. Annealing plays a vital role in avoiding cracking or breaks between the barrel and plam. Tin plating on the terminals avoids oxidization and achieves maximum corrossion protection.

COPPER CRIMPING TERMINALS FOR ALUMINIUM CONDUCTOR (LIGHT DUTY)

Material : Copper BS :1977 Finish : Electro Tinned

95

120

150

185

225

240

300

400

500

630

800

1000

23

23

26

26

26

28

28

28

32

32

35

38

38

42

42

49

53

61

67

76

10.2

12.7

10.2

12.7

16.2

10.2

12.7

16.2

12.7

16.2

16.2

16.2

20.3

16.2

20.3

20.3

20.3

20.3

-

-

20

20

22

22

22

26

26

26

30

30

34

36

36

39

39

44

48

55

65

90

12.8

12.8

14.8

14.8

14.8

16.0

16.0

16.0

18.0

18.0

20.0

22.0

22.0

24.0

24.0

28.0

30.0

35.0

39.0

43.0

58

58

62

62

62

70

70

70

83

83

95

97

97

103

103

116

120

137

165

210

15.6

15.6

17.8

17.8

17.8

19.6

19.6

19.6

22.0

22.0

24.0

26.0

26.0

28.7

28.7

33.2

36.0

41.5

46.3

53.8

CT - 19

CT - 20

CT - 21

CT - 22

CT - 23

CT - 24

CT - 25

CT - 26

CT - 27

CT - 28

CT - 231

CT - 29

CT - 30

CT - 31

CT - 32

CT - 33

CT - 34

CT - 35

CT - 62

CT - 76

SizeSq. mm Code No.

Dimensions

DE BA JC

2.5

4

6

10

16

25

35

50

70

9

11

11

11

11

13

15

15

16

16

16

20

20

20

5.2

6.2

6.2

6.2

6.2

6.2

6.2

8.2

6.2

8.2

10.2

8.2

10.2

12.7

7

7

9

9

12

12

12

12

16

16

16

18

18

18

2.0

3.1

3.8

4.4

5.3

7.0

8.0

8.0

9.2

9.2

9.2

11.5

11.5

11.5

20

22

24

24

30

37

37

37

45

45

45

56

56

56

3.7

4.8

5.5

6.2

7.1

9.0

10.0

10.0

11.2

11.2

11.2

13.8

13.8

13.8

CT - 05

CT - 06

CT - 07

CT - 08

CT - 09

CT - 10

CT - 11

CT - 12

CT - 13

CT - 14

CT - 15

CT - 16

CT - 17

CT - 18

P

T G

WL

AC

E

CA

BJ

D

Page 18: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Copper Tube Crimping Terminals With Inspection Hole are manufactured from Electrolytic Copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cables, electrical switching equipments, where vibration is critical.

Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In application subject to vibration, terminals still have to perform a reliable connection, annealing plays a vital role in avoiding cracking or breaks between the barrel and palm.

The presence of inspection hole facilitates full insertion of conductor while the barrel length has been designed to allow easy and accurate posi t ion dies d u r i n g t h e c r i m p i n g operation.

Tin plating on the terminals avoids oxidizat ion and a c h i e v e s m a x i m u m corrosion protection.

COPPER CRIMPING TERMINALS WITH INSPECTION HOLE (LIGHT DUTY)

Material Copper BS :1977Finish : Electro Tinned

SizeSq. mm Code No.

Dimensions

DE BA JC

35

50

70

95

17

17

17

17

20

20

20

20

20

20

20

20

22

22

22

6.4

8.4

10.5

13.6

6.4

8.4

10.5

13.0

6.4

8.4

10.5

13.0

8.4

10.5

13.0

15

15

15

15

16

16

16

16

20

20

20

20

23

23

23

8.0

8.0

8.0

8.0

9.2

9.2

9.2

9.2

11.6

11.6

11.6

11.6

12.8

12.8

12.8

40

40

40

40

49

49

49

49

58

58

58

58

60

60

60

10.0

10.0

10.0

10.0

11.2

11.2

11.2

11.2

13.8

13.8

13.8

13.8

15.6

15.6

15.6

CA - 35 / 6

CA - 35 / 8

CA - 35 / 10

CA - 35 / 12

CA - 50 / 6

CA - 50 / 8

CA - 50 / 10

CA - 50 / 12

CA - 70 / 6

CA - 70 / 8

CA - 70 / 10

CA - 70 / 12

CA - 95 / 8

CA - 95 / 10

CA - 95 / 12

SizeSq. mm Code No.

Dimensions

DE BA JC

120

150

185

240

300

400

500

630

800

1000

25.5

25.5

25.5

25.5

29.0

29.0

29.0

34.5

34.5

34.5

41.0

41.0

41.0

43.5

43.5

47.0

47.0

54.0

54.0

63.0

80.0

100.0

8.4

10.5

13.0

17.0

10.5

13.0

17.0

10.5

13.0

17.0

13.0

17.0

21.0

17.0

21.0

17.0

21.0

17.0

21.0

21.0

--

--

26

26

26

26

28

28

28

32

32

32

38

38

38

42

42

49

49

53

53

61

67

76

14.8

14.8

14.8

14.8

16.0

16.0

16.0

18.0

18.0

18.0

22.0

22.0

22.0

24.0

24.0

28.0

28.0

30.0

30.0

35.0

39.0

43.0

65.5

65.5

65.5

65.5

73

73

73

86.5

86.5

86.5

102

102

102

107

107

119

119

126

126

145

170

205

17.8

17.8

17.8

17.8

19.6

19.6

19.6

22.0

22.0

22.0

26.0

26.0

26.0

28.7

28.7

33.2

33.2

36.0

36.0

41.5

46.3

53.8

CA - 120 / 8

CA - 120 / 10

CA - 120 / 12

CA - 120 / 16

CA - 150 / 10

CA - 150 / 12

CA - 150 / 16

CA - 185 / 10

CA - 185 / 12

CA - 185 / 16

CA - 240 / 12

CA - 240 / 16

CA - 240 / 20

CA - 300 / 16

CA - 300 / 20

CA - 400 / 16

CA - 400 / 20

CA - 500 / 16

CA - 500 / 20

CA - 630 / 20

CA - 800 / BL

CA - 1000 / BL

E

CA

BJ

D

Page 19: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Copper Tube Crimping Terminals are manufactured from Electrolytic Copper tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cables to terminating electrical switching equipments, where vibration is critical.

Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In applicaion subject to vibration, terminals still have to perform a reliable connection, annealing plays a vital role in avoiding cracking or breaks between the barrel and palm.

The presence of inspection hole facilitates full insertion of conductor while the barrel length has been designed to allow easy and accurate position dies during the crimping operation.

Tin plating on the terminals avoids oxidization and a c h i e v e s m a x i m u m corrossion protection

COPPER CRIMPING TERMINALS WITH INSPECTION HOLE FOR COPPER CONDUCTOR (HEAVY DUTY)

SizeSq. mm Code No.

Dimensions

DE BA JC

16

25

35

50

70

12

12

12

14.5

18

13

16

16

16.5

15.3

15.3

18

17

18

18

18

18

22.0

21.0

21.0

21.0

21.0

25.0

25.0

26.0

5.2

6.4

8.4

10.5

12.7

6.4

8.4

10.5

12.7

6.5

8.4

10.5

12.7

6.5

8.4

10.5

12.7

17.0

6.4

8.4

10.5

13.0

15.0

17.0

21.0

12

12

12

13

13

12

12

12

14

12

12

12

15

16

16

16

16

18

18

18

18

18

20

20

20

5.4

5.4

5.4

5.5

5.5

6.8

6.8

6.8

6.8

8.2

8.2

8.2

8.2

9.5

9.5

9.5

9.5

9.5

11.2

11.2

11.2

11.2

11.2

11.2

11.2

30

30

32

35

39

30

37

35

40

35

35

38

42

43

43

43

43

52

50

50

50

50

55

55

55

7.1

7.1

7.1

7.9

7.9

8.8

8.8

8.8

8.8

10.6

10.6

10.6

10.6

12.4

12.4

12.4

12.4

12.4

14.7

14.7

14.7

14.7

14.7

14.7

14.7

CT - 696

CT - 354

CT - 549

CT - 657

CT - 858

CT -355

CT - 551

CT - 552

CT - 765

CT - 542

CT -356

CT - 554

CT - 853

CT - 746

CT - 357

CT - 556

CT - 698

CT - 699

CT - 748

CT - 557

CT - 358

CT - 559

CT - 795

CT - 780

CT - 781

Material Copper BS :1977Finish : Electro Tinned

SizeSq. mm Code No.

Dimensions

DE BA JC

1.5

2.5

4

6

10

8

8

10

8

10

10

11.5

10

10

10

11.5

10

12

12

15

12

12

12

14

18

4.2

5.2

6.4

4.2

5.2

6.5

8.4

4.2

5.2

6.5

8.4

5.2

6.5

8.4

10.5

5.2

6.5

8.4

10.5

12.7

5

5

5

7

7

7

7

7

7

7

7

9

9

9

9

9

9

9

10

10

1.8

1.8

1.8

2.4

2.4

2.4

2.4

3.1

3.1

3.1

3.1

3.8

3.8

3.8

3.8

4.5

4.5

4.5

4.7

4.7

16

16

18

18

20

20

24

20

20

20

25

23

27

27

32

25

25

27

32

32

3.7

3.7

3.7

4.0

4.0

4.0

4.0

4.8

4.8

4.8

4.8

5.5

5.5

5.5

5.5

6.2

6.2

6.2

7.1

7.1

CT - 711

CT - 538

CT - 539

CT - 388

CT - 540

CT - 541

CT - 762

CT - 564

CT - 389

CT - 543

CT - 763

CT - 390

CT - 544

CT - 545

CT - 854

CT - 822

CT - 353

CT - 547

CT - 855

CT - 856

Material Copper BS :1977Finish : Electro Tinned

E

CA

BJ

D

Page 20: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

SizeSq. mm Code No.

Dimensions

DE BA JC

240

300

400

500

630

800

1000

38

38

38

38

38

43

43

43

43

43

50

50

56

56

65

65

65

72.9

72.9

80.8

80.8

10.5

12.7

15.0

17.0

21.0

10.5

12.7

15.0

17.0

21.0

17.0

21.0

17.0

21.0

--

17.0

21.0

--

21.0

--

21.0

38

38

38

38

42

42

42

42

42

44

44

48

48

56

56

56

78

78

90

90

3821

21

21

21

21

23.5

23.5

23.5

23.5

23.5

26.8

26.8

30

30

35

35

35

39

39

43

43

92

92

92

92

92

101

101

101

101

101

114

114

117

124

144

144

144

170

170

200

200

26.5

26.5

26.5

26.5

26.5

30

30

30

30

30

34.8

34.8

39

39

45

45

45

50.6

50.6

56.2

56.2

CT - 787

CT -705

CT -801

CT - 244

CT - 567

CT - 568

CT - 597

CT - 802

CT - 245

CT - 569

CT - 246

CT - 571

CT - 596

CT - 247

CT - 761

CT - 807

CT - 248

CT - 599

CT - 808

CT - 590

CT - 809

Code No.

Dimensions

DE BA JC

25

25

25

26

26

28

28

28

28

28

28

28

30

30

30

30

30

30

34

34

34

34

34

8.4

10.5

13.0

15.0

17.0

21.0

8.5

10.5

12.7

15.0

17.0

21.0

8.4

10.5

12.7

15.0

17.0

21.0

10.5

12.7

15.0

17.0

21.0

20

20

20

20

22

22

22

22

22

22

22

22

26

26

26

26

26

26

32

32

32

32

32

13.5

13.5

13.5

13.5

13.5

13.5

15.0

15.0

15.0

15.0

15.0

15.0

16.5

16.5

16.5

16.5

16.5

16.5

18.5

18.5

18.5

18.5

18.5

55

55

55

55

60

60

64

64

64

64

64

64

69

69

69

69

69

69

78

78

78

78

78

17.4

17.4

17.4

17.4

17.4

17.4

19.4

19.4

19.4

19.4

19.4

19.4

21.2

21.2

21.2

21.2

21.2

21.2

23.5

23.5

23.5

23.5

23.5

CT - 752

CT - 359

CT - 561

CT - 796

CT - 672

CT - 673

CT - 782

CT - 700

CT - 241

CT - 797

CT - 546

CT - 798

CT - 783

CT - 676

CT - 242

CT - 799

CT - 564

CT - 565

CT - 652

CT - 639

CT - 800

CT - 243

CT - 704

SizeSq. mm

95

120

150

185

EXTENDED PALM BLANKS COPPER CRIMPING TERMINAL ENDS FOR COPPER CONDUCTORSBraco Copper Long Palm Terminals are

manufactured from Electrolytic Copper tube. These are used where more secured termination is required as it can easily accommodate two bolts to reduce drift. All terminals are standard with blank palm and stud holes can be punched to order. These terminals are normally used in vibrating applications. The presence of inspection hole facilitates full insertion of conductor. The terminals are tin plated to avoid oxidization and to achieve maximum corrosion protection.

SizeSq. mm Code No.

Dimensions

BA G+HC JD

50

70

95

120

150

185

240

300

400

500

625

16

18

20

22

26

32

38

42

44

48

56

9.5

11.2

13.5

15.0

16.5

18.5

21.0

23.5

28.5

30.0

35.0

42

50

52

56

64

68

80

88

104

112

132

12.4

14.7

17.4

19.4

21.2

23.5

26.5

30.0

36.5

39.0

45.0

64

75

81

88

101

112

132

145

166

180

210

18

21

25

28

30

34

38

43

53

56

65

CT - 466

CT - 467

CT - 468

CT - 469

CT - 470

CT - 471

CT - 472

CT - 473

CT - 474

CT - 475

CT - 476

Material Copper BS :1977Finish : Electro Tinned

DJ

BG+H

AC

Page 21: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Cable mm2

Stud Hole Dimensions (mm2) Cat No.

E A C B D G H J5.36.56.58.56.58.4

10.513.0

6.58.4

10.513.0

8.410.513.0

8.410.513.017.010.513.017.021.010.513.017.021.010.513.017.021.010.513.017.021.010.513.017.021.010.513.017.021.013.017.021.017.021.021.021.0

3.83.84.54.55.55.55.55.57.07.07.07.08.28.28.2

10.010.010.010.011.511.511.511.513.513.513.513.515.515.515.515.517.017.017.017.019.019.019.019.021.521.521.521.524.024.024.027.527.531.034.5

5.55.56.06.08.58.58.58.5

10.010.010.010.012.512.512.514.514.514.514.516.516.516.516.519.019.019.019.021.021.021.021.023.523.523.523.525.525.525.525.529.029.029.029.032.032.032.038.538.542.044.0

1010101020202020202020202020202828282828282828353535353535353535353535404040404040404050505070707080

8.58.58.58.512121719151517191719212222232824243232282832343232323234343440373737404242424648484855556060

6.57.57.5

10.07.5

10.012.013.0

7.510.012.013.0

7.510.012.010.012.013.014.510.012.013.014.512.012.013.014.518.019.015.016.015.016.019.016.015.016.019.019.015.016.019.021.019.019.021.025.025.025.025.0

7.58.08.0

10.08.0

10.012.013.0

8.010.012.013.0

8.010.012.010.012.013.014.510.012.013.014.512.012.013.014.516.017.019.020.016.017.020.020.016.017.020.020.016.017.020.020.022.022.022.025.025.025.025.0

31323537434549504749515250525461636466646667697676808283848788929396969697

100100106107110112119119121140140152160

6-5 DIN6-6 DIN

10-6 DIN10-8 DIN16-6 DIN16-8 DIN

16-10 DIN16-12 DIN25-6 DIN25-8 DIN

25-10 DIN25-13 DIN35-8 DIN

35-10 DIN35-12 DIN50-8 DIN

50-10 DIN50-12 DIN50-16 DIN70-10 DIN70-12 DIN70-16 DIN70-20 DIN95-10 DIN95-12 DIN95-16 DIN95-20 DIN

120-10 DIN120-12 DIN120-16 DIN120-20 DIN150-10 DIN150-12 DIN150-16 DIN150-20 DIN185-10 DIN185-12 DIN185-16 DIN185-20 DIN240-10 DIN240-12 DIN240-16 DIN240-20 DIN300-12 DIN300-16 DIN300-20 DIN400-16 DIN400-20 DIN500-20 DIN652-20 DIN

6

10

16

25

35

50

70

95

120

150

185

240

300

500

625

400

Braco copper tube terminals are manufactured from Electrolytic Copper Tube. The dimensions of the tube are designed to obtain the most efficient electrical conductivity and mechanical strength to resist vibration and pull out. These are used for terminating any size of cable, electrical switching equipments, where vibration is critical.

Terminals are annealed to guarantee optimum ductility which is an absolute necessity for connectors which will have to withstand the sever deformation arising when compressed and any bending of the palm during installation. In application subject to vibration terminals still have to perform a reliable connection, annealing plays a vital role in avoiding crackings or breaks between the barrel and palm.

The terminals are designed as per DIN standard 46235. The plating on the terminals avoids oxidization and achieves maximum corrosion protection.

COPPER CRIMPING TERMINALS AS PER DIN STANDARDSBraco Copper Long Barrel Tube Terminals are made from high purity copper tube and are annealed to avoid cracking or breaks. The increased barrel length ensures enhanced electrical and mechanical performance in heavy duty application. The absence of an inspection hole prevents the entry of water or moisture into crimped joints making them suitable for outdoor applications. The terminals are tin plated to avoid oxidization and to achieve maximum corrossion protection.

COPPER CRIMPING TERMINALS FOR COPPER CONDUCTORS (LONG BARREL)

Material Copper BS :1997Finish : Electro Tinned

SizeSq. mm Code No.

Dimensions

DE BA JC

25

35

50

70

95

120

150

185

240

300

400

500

630

800

1000

13.0

15.0

17.0

20.0

24.0

28.0

30.0

34.0

40.0

43.0

50.0

56.0

65.0

72.9

80.8

8.2

8.2

8.2

10.5

12.7

12.7

12.7

12.7

16.2

16.2

20.3

21.0

21.0

-

-

16

20

26

28

32

35

38

43

50

55

58

48

76

105

130

7.0

8.0

9.2

11.5

12.8

14.8

16.0

18.0

22.0

23.5

26.8

30

35

39

43

41

48

59

66

74

82

86

95

112

120

135

124

165

200

240

9.0

10.6

12.2

15.0

17.0

19.6

21.2

24.0

28.0

30.0

34.8

39.00

45.0

50.6

56.2

CT - 82

CT - 83

CT - 84

CT - 85

CT - 86

CT - 87

CT - 88

CT - 89

CT - 90

CT - 91

CT - 92

CT - 93

CT - 94

CT - 95

CT - 96

E

B

J

CA

D

Page 22: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco connectors are designed for jointing low voltage conductors. Made of electrolytic copper tube having the same dimension as CT series lugs, Braco connectors are annealed and electrolytic ally tin plated. They feature an internal taper at both ends to ease the introduction of conductor and a dimple (if required) to ensure correct positioning. These connectors can also be provided with insulation. Tinning on connectors provides better finish, avoids oxidisation and achieves maximum corrossion protection

COPPER TUBE IN-LINE CONNECTORS

(Short Barrel)

ILC-453

ILC-454

ILC-3

ILC-4

ILC-460

ILC-6

ILC-24

ILC-25

ILC-26

ILC-51

ILC-52

ILC-53

ILC-54

ILC-55

ILC-56

ILC-57

ILC-58

ILC-59

ILC-61

ILC-62

ILC-63

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

800

1000

1.6

2.4

3.1

3.8

4.5

5.4

6.8

8.2

9.5

11.2

13.5

15.0

16.5

18.5

21.0

23.5

26.8

30.0

35.0

39.0

43.0

3.2

4.0

4.8

5.5

6.2

7.1

8.8

10.6

12.4

14.7

17.4

19.4

21.2

23.5

26.8

30.0

34.8

39.0

45.0

50.6

56.2

15.0

15.0

15.0

15.0

20.0

20.0

32.0

36.0

40.0

40.0

45.0

45.0

55.0

65.0

80.0

85.0

90.0

100.0

110.0

150.0

170.0

BracoCat. No.

SizeSq. mm.

Dimensions

d1 d3 J

ILC-41

ILC-42

ILC-43

ILC-44

ILC-45

ILC-46

ILC-47

ILC-48

ILC-49

ILC-27

ILC-28

ILC-29

ILC-30

ILC-31

ILC-32

ILC-33

ILC-34

ILC-35

ILC-36

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

1.6

2.4

3.1

3.8

4.5

5.4

6.8

8.2

9.5

11.2

13.5

15.0

16.5

18.5

21.0

23.5

26.8

30.0

35.0

3.2

4.0

4.8

5.5

6.2

7.1

8.8

10.6

12.4

14.7

17.4

19.4

21.2

23.5

26.8

30.0

34.8

39.0

45.0

22.0

22.0

22.0

22.0

22.0

35.0

47.0

45.0

50.0

50.0

60.0

65.0

70.0

75.0

89.0

95.0

110.0

117.0

120.0

BracoCat. No.

SizeSq. mm.

Dimensions

d1 d3 J

(Long Barrel)

CA

J

COPPER IN-LINE CONNECTORS

SizeSq. mm Code No.

Dimensions

A1A C1C J1J

1.5

2.5

4.5

3.3

4.1

5.6

1.6

2.4

3.5

3.2

4.0

5.5

25

25

27

15

15

15

ILCI - 63

ILCI - 64

ILCI - 65

4.9

5.5

7.2

1.5 2.5 4.6

Colour Coding Insulated Terminals:

J-1

A1C1 AC

J

Page 23: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

COPPER CRIMPING REDUCER TERMINALS FOR ALUMINIUM CONDUCTORBraco Copper Crimping Reducer Terminals are

used to terminate one or more Aluminium conductors to a smaller termination area. These type of terminals are applicable in tunnel type terminal blocks viz. fuse gears, cut-outs, meters etc. Braco is able to produce any Copper Reducing Link that you may require. The presence of copper at termination end ensures high current carrying capacity at smaller surface area. Tinning avoids oxidisation and provides maximum corrosion protection.

Material : Copper BS 1977Finish : Electro Tinned

SizeSq. mm Code No.

Dimensions

D-1A BC JD

2.5

4

6

10

16

25

35

50

4.0

3.3

4.0

3.3

4.0

3.3

4.0

3.3

4.0

3.3

5.5

5.5

3.3

5.5

6.5

6.5

6.5

13.0

2.5

2.5

2.8

2.8

3.1

3.1

3.8

3.8

4.4

4.4

5.3

5.3

5.3

7.0

7.0

8.0

9.2

10.4

6

6

6

6

6

6

9

9

9

9

12

12

12

12

12

12

16

18

4.7

4.7

4.7

4.7

4.7

4.7

5.5

5.5

6.2

6.2

7.1

7.1

7.1

9.0

9.0

10.0

11.2

14.0

20

20

20

20

20

20

23

23

23

23

32

37

30

32

37

37

41

49

4.5

3.8

4.5

3.8

4.5

3.8

4.5

3.8

4.5

3.8

6.0

6.0

3.8

6.0

7.5

7.5

7.5

14.0

WPC - 1

WPC - 7

WPC - 15

WPC - 16

WPC - 17

WPC - 18

WPC - 19

WPC - 20

WPC - 21

WPC - 22

WPC - 23

WPC - 24

WPC - 2

WPC - 25

WPC - 3

WPC - 4

WPC - 26

WPC - 5

SizeSq. mm Code No.

Dimensions

D-1A BC JD

70

95

120

150

185

225

240

300

400

6.5

10.5

10.5

10.5

6.5

11.8

6.5

10.5

14.0

10.5

14.0

10.5

14.0

15.0

14.0

15.0

14.0

14.0

11.5

11.5

11.5

12.8

12.8

12.8

14.8

14.8

16.0

16.0

18.0

18.0

20.0

22.0

22.0

24.0

24.0

27.0

18

18

18

20

20

20

22

22

26

26

32

32

38

38

38

42

42

46

13.8

13.8

13.8

15.6

15.6

15.6

17.8

17.8

19.6

19.6

22.0

22.0

26.0

26.0

26.0

28.7

28.7

33.2

43

48

55

51

48

58

50

60

64

64

70

70

78

88

78

92

82

90

7.5

11.5

11.5

11.5

7.5

12.8

7.5

11.5

15.6

11.5

15.6

11.5

15.6

16.0

16.0

16.0

16.0

16.0

WPC - 27

WPC - 6

WPC - 28

WPC - 29

WPC - 31

WPC - 32

WPC - 34

WPC - 35

WPC - 10

WPC - 37

WPC - 30

WPC - 38

WPC - 39

WPC - 44

WPC - 43

WPC - 45

WPC - 47

WPC - 101

J

AC

D

D1

Page 24: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Bi-metallic terminals for aluminium conductor are manufactured from solid materials by friction welding. This method means that aluminium and Copper join through the heat, which develops when aluminium rotates against copper under pressure. This is a superior method to give a complete connection between Aluminium and Copper. Barrels are caped and filled with grease so as to avoid oxidisation of the aluminium.

BI-METALLIC TERMINALS

Material : Aluminium 99.5, E CopperSurface : Bright

16 13 5.5 16 24 87 BMT-16

25 13 6.5 16 24 87 BMT-25

35 13 8.0 16 24 87 BMT-35

50 13 9.0 20 24 87 BMT-50

70 13 11.0 20 24 87 BMT-70

95 13 12.5 20 24 87 BMT-95

120 13 13.7 25 31 111 BMT-120

150 13 15.5 25 31 111 BMT-150

185 13 17.0 32 35 116 BMT-185

240 13 19.5 32 35 116 BMT-240

300 13 22.5 34 35 120 BMT-300

SIZESq.mm. E A C D J

CAT NO.Dimension

JC

A

D

E

BI-METALLIC PIN TERMINALSBraco Bi-metallic Connectors are made from aluminium purity equal to or greater than 99.5 %. The barrel is friction welded to the pin thus achieving the best possible transition between the copper pin and aluminium barrel.Barrels are capped and filled with grease so as to avoid oxidisation of the aluminium.

Material : Aluminium 99.5; E CopperSurface : Bright

16 5.5 16 8 30 82 BMP-16

25 6.5 16 8 30 82 BMP-25

35 8.0 16 8 30 82 BMP-35

50 9.0 20 12 45 97 BMP-50

70 11.0 20 12 45 97 BMP-70

95 12.5 20 12 45 97 BMP-95

120 13.7 25 14 55 125 BMP120

150 15.5 25 14 55 125 BMP-150

185 17.0 32 14 55 125 BMP-185

240 19.5 32 14 55 125 BMP 240

SIZESq.mm. A C D-1 J

CAT NO.P

DIEMENSIONS

D1

CAJ

P

Page 25: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco Aluminium Crimping Terminals are manufactured out of tubes of purity equal to or greater than 99.5%, hav ing max imum conductivity not less than 60% IACS and are designed as per IS 8309 1993 These are used for terminating all sizes of cables to terminate electrical switching equipments. The absence of an inspection hole prevents the entry of water or moisture into crimped joints making them suitable for outdoor applications.

ALUMINIUM CRIMPING TERMINALS

Material : Aluminium IS: 5082 :1981

SizeSq. mm Code No.

Dimensions

DE BA JC

2.5

4

6

10

16

25

35

50

70

7

7

7

12

8

12

10

15

11

11

18

14

14

20

20

15

15

20

18

23

23

22

22

22

3.2

3.7

4.2

5.2

5.2

6.4

6.4

8.2

6.4

8.2

10.2

6.4

8.2

10.2

12.7

6.4

8.2

10.2

8.2

10.2

12.7

8.2

10.2

12.7

7

7

7

7

7

7

9

9

13

13

13

16

16

16

16

18

18

18

22

22

22

26

26

26

2.0

2.6

2.9

2.9

3.5

3.5

4.4

4.4

5.4

5.4

5.4

7.0

7.0

7.0

7.0

8.0

8.0

8.0

9.3

9.3

9.3

11.6

11.6

11.6

18

18

18

24

24

24

30

30

37

37

37

44

44

44

44

47

47

47

54

54

54

60

60

60

5.5

5.5

5.5

5.5

5.5

5.5

7.4

7.4

8.3

8.3

8.3

10.0

10.0

10.0

10.0

10.8

10.8

10.8

13.0

13.0

13.0

16.0

16.0

16.0

AT - 151

AT - 309

AT - 155

AT - 317

AT - 158

AT - 313

AT - 214

AT - 215

AT - 252

AT - 216

AT - 217

AT - 253

AT - 218

AT - 219

AT - 220

AT - 254

AT - 221

AT - 222

AT - 255

AT - 312

AT - 224

AT - 256

AT - 225

AT - 226

ALUMINIUMALUMINIUMALUMINIUMALUMINIUM

E

CA

BJ

D

Page 26: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

SizeSq. mm Code No.

Dimensions

DE BA JC

95

120

150

185

225

240

300

400

500

630

800

1000

25.0

25.0

25.0

28.0

28.0

28.0

31.0

31.0

31.0

34.0

34.0

34.0

39.0

40.0

40.0

40.0

45.7

45.7

51.0

58.0

66.0

73.0

81.0

10.2

12.7

16.2

10.2

12.7

16.2

10.2

12.7

16.2

10.2

12.7

16.2

12.7

12.7

16.2

20.0

16.2

20.3

20.3

20.3

20.3

--

--

28

28

28

32

32

32

34

34

34

36

36

36

40

44

44

44

47

47

56

60

69

77

100

12.9

12.9

12.9

14.8

14.8

14.8

16.1

16.1

16.1

18.0

18.0

18.0

20.6

22.0

22.0

22.0

24.0

24.0

28.0

30.0

35.0

39.0

43.5

64

64

64

73

73

73

79

79

79

84

84

84

94

102

102

102

115

115

130

140

154

180

220

17.1

17.1

17.1

19.6

19.6

19.6

21.2

21.2

21.2

23.7

23.7

23.7

27.0

28.0

28.0

28.0

31.0

31.0

36.0

41.0

46.0

51.0

57.0

AT - 227

AT - 228

AT - 229

AT - 257

AT - 230

AT - 231

AT - 258

AT - 232

AT - 233

AT - 311

AT - 234

AT - 235

AT - 320

AT - 236

AT - 237

AT - 238

AT - 300

AT - 259

AT - 260

AT - 296

AT - 261

AT - 318

AT - 319

Braco AT - XL type of terminals are manufactured out of tubes of purity equal to or greater than 99.5% having maximum conductivity not less than 60% IACS and are suitable for high voltage application where termination of XLPE cable is required.

ALUMINIUM TUBE TERMINALS FOR AL-XLPE CONDUCTORS

SizeSq. mm

Code No.

Dimensions

DE BA JG+HC

25

35

50

70

95

120

150

185

225

240

300

400

500

630

800

1000

14

16

19.5

20.5

23.5

26.5

29.5

33.0

36.0

37.5

42.0

48.0

54.0

61.0

68.0

77.5

8.2

8.2

10.2

10.2

12.7

12.7

12.7

12.7

12.7

12.7

20.3

20.3

20.3

20.3

20.3

20.3

41

50

49

62

73

73

83

83

86

86

89

113

125

140

147

160

21

22

24

26

28

30

34

36

40

44

54

60

64

68

78

90

7.2

8.3

9.3

10.2

12.0

13.7

15.1

16.6

18.6

19.3

21.8

25.0

28.2

31.7

35.7

41.0

69

79

81

96

109

114

128

131

140

144

157

187

205

225

250

280

9.6

11.1

13.5

14.5

16.6

19.0

21.1

23.9

26.1

27.2

30.2

34.8

39.1

44.4

49.5

56.0

AT - XL 17

AT - XL 18

AT - XL 19

AT - XL 20

AT - XL 21

AT - XL 22

AT - XL 23

AT - XL 24

AT - XL 25

AT - XL 26

AT - XL 27

AT - XL 28

AT - XL 29

AT - XL 30

AT - XL 31

AT - XL 32

Material : Aluminium IS :5082 1981:

E

CA

BJ

D

E

BJ

CA

D

Page 27: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

ALUMINIUM CRIMPING CONNECTORBraco Aluminium Crimping In-Line Connectors are made out of tubes of purity equal to or greater than 99.5% having maximum conductivity not less than 60% IACS and the designed as per IS 8309 1993. These connectors facilitate joining two identical size Aluminium conductors.

SizeSq. mm Code No.

Dimensions

A C J

2.5

4

6

10

16

25

35

50

70

95

120

150

185

225

240

300

400

500

630

800

1000

2.0

2.6

2.9

3.5

4.4

3.8

5.4

7.0

8.0

9.3

11.6

12.9

14.8

16.1

18.0

20.6

22.0

24.0

28.0

30.0

35.0

39.0

43.5

5.5

5.5

5.5

5.5

7.4

6.2

8.3

10.0

10.8

13.0

16.0

17.1

19.6

21.2

23.7

27.0

28.0

31.0

36.0

41.0

46.0

51.0

57.0

16

16

16

16

20

20

26

35

40

45

55

60

65

70

75

85

90

100

115

125

140

160

210

ILA - 145

ILA - 6

ILA - 5

ILA - 13

ILA - 14

ILA - 146

ILA - 4

ILA - 3

ILA - 2

ILA - 12

ILA - 1

ILA - 15

ILA - 9

ILA - 10

ILA - 11

ILA - 147

ILA - 16

ILA - 17

ILA - 18

ILA - 19

ILA - 20

ILA - 148

ILA - 149

Material : Aluminium IS :5082 :1981

Braco Aluminium Reducer Terminals are manufactured out of aluminium of purity equal to or greater than 99.5 % having maximum coductivity not less than 60% IACS. These are used to terminate one or more Aluminium conductors to a smaller termination area. Braco is able to produce any Aluminium Reducing Link that you may require.

ALUMINIUM CRIMPING REDUCER TERMINALS FOR ALUMINIUM CONDUCTOR

SizeSq. mm Code No.

Dimensions

D-1A BC JD

2.5

4

6

10

16

25

35

50

70

4.0

3.3

4.0

3.3

4.0

3.3

4.0

3.3

4.0

3.3

5.5

5.5

3.3

5.5

6.5

6.5

6.5

13.0

6.5

10.5

10.5

2.6

2.6

2.9

2.9

3.5

3.5

3.8

3.8

4.4

4.4

5.4

5.4

5.4

7.0

7.0

8.0

9.3

10.4

11.6

11.6

11.6

7

7

7

7

7

7

9

9

9

9

13

13

13

16

16

18

22

22

26

26

26

5.5

5.5

5.5

5.5

5.5

5.5

7.4

7.4

7.4

7.4

8.3

8.3

8.3

10.0

10.0

10.8

13.0

14.0

16.0

16.0

16.0

21

21

21

21

21

21

23

23

23

23

33

38

31

36

41

43

47

53

51

56

63

4.5

3.5

4.5

3.8

4.5

3.8

4.5

3.8

4.5

3.8

6.0

6.0

3.8

6.0

7.5

7.5

7.5

14.0

7.5

11.5

11.5

WPA - 1

WPA - 7

WPA - 15

WPA - 16

WPA - 17

WPA - 18

WPA - 19

WPA - 20

WPA - 21

WPA - 22

WPA - 23

WPA - 24

WPA - 2

WPA - 25

WPA - 3

WPA - 4

WPA - 26

WPA - 5

WPA - 27

WPA - 6

WPA - 28

Material : Aluminium IS :5082 :1981

J

AC

D

D1

C A

J

Page 28: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

SizeSq. mm Code No.

Dimensions

D-1A BC JD

95

120

150

185

240

300

10.5

14.0

6.5

11.8

10.5

6.5

10.5

14.0

14.0

14.0

14.0

10.5

14.0

18.0

15.0

15.0

14.0

15.0

14.0

12.9

12.9

12.9

12.9

14.8

14.8

14.8

14.8

16.1

16.1

18.0

18.0

20.6

20.6

20.6

22.0

22.0

24.0

24.0

28

28

28

28

32

32

32

32

34

34

36

36

40

40

40

44

44

47

47

17.1

17.1

17.1

17.1

19.6

19.6

19.6

19.6

21.2

21.2

23.7

23.7

27.0

27.0

27.0

28.0

28.0

31.0

31.0

59

61

56

66

63

60

70

70

72

72

74

74

80

90

90

94

84

94

84

11.5

15.6

7.5

12.8

11.5

7.5

11.5

15.6

15.6

15.6

15.6

11.5

15.6

21.0

16.0

16.0

15.6

16.0

15.6

WPA - 29

WPA - 8

WPA - 31

WPA - 32

WPA - 33

WPA - 34

WPA - 35

WPA - 36

WPA - 10

WPA - 37

WPA - 30

WPA - 38

WPA - 39

WPA - 46

WPA - 42

WPA - 44

WPA - 43

WPA - 45

WPA - 47

Braco long barrel aluminium crimping terminals are manufactured out tubes drawn to the required sizes having minimum conductivity not less than 60% IACS and as per IS 158309 1993

These are used for terminating all sizes of cables to terminate electrical switching equipments. The increased barrel length ensures enhanced electrical and mechanical performance due to more number of crimps. The absence of inspection hole prevents the entry of water or moisture into crimped joints making them suitable for outdoor applications.

LONG BARREL ALUMINIUM CRIMPING TERMINALS FOR ALUMINIUM CONDUCTOR

2.5

2.5

4

4

6

6

10

10

16

16

16

25

25

25

35

35

50

50

50

70

70

70

95

95

95

120

120

120

150

150

150

185

185

185

225

240

240

300

300

400

500

630

800

1000

3.2

3.7

4.2

5.2

5.2

6.4

6.4

8.2

6.4

8.2

10.2

8.2

10.2

12.7

8.2

10.2

8.2

10.2

12.7

8.2

10.2

12.7

10.2

12.7

16.2

10.2

12.7

16.2

10.2

12.7

16.2

10.2

12.7

16.2

12.7

12.7

16.2

16.2

20.3

20.3

20.3

20.3

-

-

2.0

2.6

2.9

2.9

3.5

3.5

4.4

4.4

5.4

5.4

5.4

7.0

7.0

7.0

8.0

8.0

9.3

9.3

9.3

11.6

11.6

11.6

12.9

12.9

12.9

14.8

14.8

14.8

16.1

16.1

16.1

18.0

18.0

18.0

20.6

22.0

22.0

24.0

24.0

28.0

30.0

35.0

39.0

43.5

5.5

5.5

5.5

5.5

5.5

5.5

7.4

7.4

8.3

8.3

8.3

10.0

10.0

10.0

10.8

10.8

13.0

13.0

13.0

16.0

16.0

16.0

17.1

17.1

17.1

19.6

19.6

19.6

21.2

21.2

21.2

23.7

23.7

23.7

27.0

28.0

28.0

31.0

31.0

36.0

41.0

46.0

51.0

57.0

7.0

7.0

7.0

12.0

8.0

12.0

10.0

15.0

11.0

11.0

18.0

14.0

20.0

20.0

15.0

20.0

18.0

23.0

23.0

22.0

22.0

22.0

25.0

25.0

25.0

28.0

28.0

28.0

31.0

31.0

31.0

34.0

34.0

34.0

39.0

40.0

40.0

45.7

45.7

51.0

58.0

66.0

73.0

81.0

10.5

10.5

10.5

10.5

10.5

10.5

13.5

13.5

19.5

19.5

19.5

24.0

24.0

24.0

27.0

27.0

33.0

33.0

33.0

39.0

39.0

39.0

42.0

42.0

42.0

48.0

48.0

48.0

51.0

51.0

51.0

54.0

54.0

54.0

60.0

66.0

66.0

70.5

70.5

84.0

90.0

103.5

115.5

150.0

21.5

21.5

21.5

27.5

27.5

27.5

34.5

34.5

43.5

43.5

43.5

52.0

52.0

52.0

56.0

56.0

65.0

65.0

65.0

73.0

73.0

73.0

78.0

78.0

78.0

89.0

89.0

89.0

96.0

96.0

96.0

102.0

102.0

102.0

114.0

124.0

124.0

138.5

138.5

158.0

170.0

188.5

218.5

270.0

AT- 551

AT- 509

AT- 555

AT-517

AT-558

AT-513

AT-514

AT-515

AT-552

AT-516

AT-517

AT-518

AT-519

AT-520

AT-521

AT-522

AT-655

AT-512

AT-524

AT-556

AT-525

AT-526

AT-527

AT-528

AT-529

AT-557

AT-530

AT-531

AT-658

AT-532

AT-533

AT-511

AT-534

AT-535

AT-620

AT-536

AT-537

AT-500

AT-559

AT-560

AT-596

AT-561

AT-618

AT-619

E A C D B J CAT NOCABLE SIZE

MM2

Dimensions

Material : Aluminium IS :5082 :1981

J

AC

D

D1

E

B

J

CA

D

Page 29: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco double hole Aluminium crimping terminals which are also known as "Non Rotating Terminals" are manufactured out of tubes drawn to the required sizes having minimum conductivity not less than 60% IACS . The increased barrel length ensures enhanced electrical and mechanical performance due to more number of crimps. Two holes ensures non-rotation in the equipments such as transformers,moving equipments where vibration is critical.The holes can be punched as per requirement.

DOUBLE HOLE ALUMINIUM CRIMPING TERMINALS FOR

ALUMINIUM CONDUCTORS

35

50

70

95

120

150

185

240

300

400

500

12

12

12

12

12

16

16

16

16

16

16

8

9.7

11

13.1

14.7

16.5

18.1

21

23.2

26

29

15

18

18

20

22

25

31

31

38

40

45

22

25

25

28

32

36

45

45

55

58

65

44

44

44

44

44

44

44

44

44

44

44

50

50

62

73

73

83

83

86

89

113

125

133

133

145

157

160

174

175

180

183

207

221

ATT-35-12

ATT-50-12

ATT-70-12

ATT-95-12

ATT-120-12

ATT-150-16

ATT-185-16

ATT-240-16

ATT-300-16

ATT-400-16

ATT-500-16

E A C D G B J CAT NOCABLE SIZE

MM2

Dimensions

Material : Aluminium IS :5082 :1981

ALUMINIUM ALLOY TUBULAR BIMETALLIC TERMINALSBraco Aluminium alloy tubular bi-metallic terminals are manufactured out of aluminium of purity equal to or greater than 99.5 % having maximum coductivity not less than 60% IACS. These are anti-corrosive and used for highly corrosive environment. The barrels are kept filled with grease so as to avoid oxidization of the Aluminium. These are designed to accept a variety of conductor forms especially low stranded compacted conductors.These terminals are mainly used to terminate on copper bus bars. Whenever aluminium links terminated on to copper or copper based alloy terminals without suitable plating, results in the corrossion of the joint over a period leading to higher joint resistance.Bi-metallic terminals are found most reliable and suitable for such connections.

150

185

225

240

300

400

500

630

800

1000

16.1

16.1

18.0

18.0

20.6

22.0

22.0

24.0

24.0

28.0

30.0

35.0

39.0

43.5

12

16

12

16

12

12

16

16

20

20

20

20

--

--

34

34

36

36

40

44

44

47

47

56

60

69

77

100

21.2

21.2

23.7

23.7

27.0

28.0

28.0

31.0

31.0

36.0

41.0

46.0

51.0

57.0

79

79

84

84

94

102

102

115

115

130

140

154

180

220

31.0

31.0

34.0

34.0

39.0

40.0

40.0

45.7

45.7

51.0

58.0

66.0

73.0

81.0

ATB - 17

ATB - 18

ATB - 19

ATB - 20

ATB - 21

ATB - 22

ATB - 23

ATB - 24

ATB - 25

ATB - 26

ATB - 27

ATB - 28

ATB - 29

ATB - 30

SizeSq. mm Code No.

Dimensions

AE BC JD

SizeSq. mm Code No.

Dimensions

AE BC JD

10

16

25

35

50

70

95

120

4.4

4.4

5.4

5.4

7.0

7.0

8.0

8.0

9.3

9.3

11.6

11.6

12.9

12.9

14.8

14.8

6

8

6

8

8

10

8

10

8

10

10

12

10

12

10

12

30

30

37

37

44

44

47

47

54

54

60

60

64

64

73

73

ATB - 1

ATB - 2

ATB - 3

ATB - 4

ATB - 5

ATB - 6

ATB - 7

ATB - 8

ATB - 9

ATB - 10

ATB - 11

ATB - 12

ATB - 13

ATB - 14

ATB - 15

ATB - 16

7.4

7.4

8.3

8.3

10.0

10.0

10.8

10.8

13.0

13.0

16.0

16.0

17.1

17.1

19.6

19.6

10

15

11

11

14

20

15

20

18

23

22

22

25

25

28

28

9

9

13

13

16

16

18

18

22

22

26

26

28

28

32

32

Material : Aluminium IS :5082 :1981

J

B

AC

E

D

E

B

J

CA

D

Page 30: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Characteristics:

Installation Instructions :

SINGLE COMPRESSION GLANDSBraco single compression Brass Cable Glands are suitable for armoured / unarmoured cables. These are manufactured out of brass castings and are machined accurately to the required sizes These glands are nickel plated to avoid corrosion while storage and use.

Each gland comprises of Brass Body with nipple thread as per I.S. 1653 Compression nut, Check nut, Rubber Ring and three metal washers. The detail parts are shown in the functional drawing.

These glands are weather proof and watertight and have provision for earthing the armoured cables. These glands are available in various different sizes and are suitable for all cables up to 1000 sq.mm. and control cables up to 61 cores The entry thread on gland body is normally threaded according to IS 1653 (Steel conduits for electrical wiring). However if any special kind of thread required, the same can be supplied. The glands can be supplied with special plating such as cadmium, tin or passivated.

• Washers of soft metal will be provided for firm gripping of armour• Earth tag will be provided if required at extra cost • PVC protective shrouds can be supplied at extra cost. • Washers between rubber ring are supplied for uniform radial gripping.

Characteristics

Selection

•• Diameter of cable underneath the overall sheating for unarmoured cable and

underneath the armouring for armoured cables is not more than D-34.• Selection of rubber ring is made such that the dia over armouring for armoured

cables and dia underneath the overall sheathing for unarmoured cable is less than rubber I.D. A-1.

O. D of cable should be less than D-3

Parts

1. Compression Nut2. Brass Body3. Three Metal Washers4. Rubber Ring5. Check Nut

Material

Brass

Finish

Nickle Plated

Glands Ref.NIP. OD CAP. BORING NIP. ID A.CROSS. BODY HIGHT NIP. HIGHT B. NUT RUB. ID Cable diameter (mm)

E D-3 D-3 A D L-9 L-10 M A-1 above upto

BC-3/8" 1/2" 14.00 12.00 20.00 10.50 6.00 2.00 8.00 9 13.5

BC-1/2"L 5/8" 15.00 13.00 23.00 12.50 6.50 2.00 12.00 10 14.5

BC-1/2"H 5/8" 15.00 13.00 23.50 14.00 7.50 3.00 12.00 10 14.5

BC-5/8"L 3/4" 15.00 15.00 23.00 14.00 7.00 2.00 12.00 10 14.5

BC-5/8"H 3/4" 15.00 15.00 23.50 15.00 8.00 3.00 12.00 10 14.5

BC-3/4"L 3/4" 17.50 15.00 26.00 15.50 8.00 2.50 14.00 14 17

BC-3/4"H 3/4" 17.50 15.00 27.50 16.50 9.00 3.00 14.00 14 17

BC-7/8"L 3/4" 20.00 15.00 29.00 16.00 8.00 2.50 16.00 17 19.5

BC-7/8"H 3/4" 20.00 15.00 29.50 17.00 9.00 3.00 16.00 17 19.5

BC-1"L 1" 23.50 21.50 32.50 17.50 8.00 3.00 20.00 19.5 23

BC-1"H 1" 23.50 21.00 34.50 19.00 10.00 3.50 20.00 19.5 23

BC-1"S 3/4" 23.50 15.00 32.50 17.50 8.00 3.00 18.00 19.5 23

BC-1-1/8" 1-1/8" 28.00 25.00 39.00 21.00 10.50 4.00 25.00 23 27

BC-1-1/4" 1-1/4" 31.50 27.00 42.50 21.00 10.50 4.00 27.00 27 30

BC-1-3/8" 1-3/8" 35.50 31.00 47.50 22.00 10.50 4.50 31.00 30 34

BC-1-1/2" 1-1/2" 39.00 34.00 52.00 22.00 10.50 4.50 33.00 34 38

BC-1-3/4" 1-3/4" 45.00 40.00 59.00 23.00 11.50 4.50 39.00 38 44

BC-2" 2" 51.50 45.00 68.00 23.00 11.50 4.50 44.00 44 50

BC-2-1/4" 2-1/4" 58.00 52.00 75.00 23.50 11.50 5.00 52.00 50 56.5

BC-2-1/2" 2-1/2" 62.50 58.00 80.00 25.00 13.00 5.50 58.00 56.5 61

BC-2-3/4" 2-3/4" 70.00 65.50 90.00 28.00 13.50 5.50 65.00 61 68

BC-3" 3" 76.00 69.50 100.00 28.00 13.50 5.50 70.00 68 74

BC-3-1/4" 3-1/4" 82.00 75.00 115.00 29.00 15.00 5.50 75.00 74 80

BC-3-1/2" 3-1/2" 88.00 82.00 117.00 29.00 15.00 6.00 80.00 80 86

BC-4" 4" 100.00 92.50 127.00 36.00 20.00 6.00 86.00 86 98

BC-4-1/2" 4-1/2" 108.00 102.00 145.00 38.00 23.00 7.00 90.00 98 105

A-1

B-1

D-3

L-9

M

L-10

FU

NC

TIO

NA

L D

ES

IGN

D Across Corner

D-3

E

Page 31: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

DOUBLE COMPRESSION GLANDS ( Weather Proof )Braco Double Compression glands are manufactured out of brass rods/castings and are machined accurately to the required sizes. These are nickel plated to avoid corrosion whilst storage and use.

These glands have two moisture proof seals and may be used under most climatic conditions. These are weather proof and waterproof and when protected by a PVC shroud these can be used under most corrosive conditions. The armour cone and ring gives excellent mechanical and electrical connections.

These glands are as per BS6121 1973 and have ten parts: Brass Body, Armour Clamp and Ring, Gland Barrel sealing nut, two pcp seals, the skid washer check nut and flat washer between the gland barrel and check nut is provided to prevent the drag on outer seal. The detail parts are shown in functional drawing.

These glands are available in various different sizes and are suitable for all cables up to 1000 sq.mm. and control cables up to 61 cores. The entry threads on gland barrel are normally threaded according to IS 1653 (Steel conduits for electrical wiring), however if any special kind of gland or thread is required, the same can be supplied on request.

The gland can also be supplied with any other special plating such as cadmium, tin or pasivated. Also the glands can be supplied made out of aluminium, mild steel or stainless steel.

Characteristics:•• Earthing tag will be provided if required at extra cost.• PVC protective shroud can be supplied at extra cost.• Washers between seals are supplied for uniform radial gripping of PCP seals.

Clamping cone will be provided with knurling for firm gripping of the armour.

BRACOCAT. No.

B A E E

NippleBSC

(INCH)D Max. Accept. Dia

From To

BPW 3/8”

BPW ½”

BPW 5/8”

BPW 001

BPW 01

BPW 01L

BPW 02

BPW 02S

BPW 03

BPW 04

BPW 04L

BPW 05

BPW 06

BPW 06S

BPW 07

BPW 08

BPW 09

BPW 010

BPW 011

BPW 012

BPW 013

BPW 014

BPW 015

BPW 016

13.0

14.0

15.0

17.0

18.5

18.5

20.5

20.5

23.0

27.0

27.0

30.5

33.5

33.5

37.5

42.0

47.0

53.0

61.0

68.0

79.0

84.0

94.0

103.0

11.0

11.0

13.0

13.0

13.0

15.0

15.0

13.0

17.0

20.5

24.0

24.0

28.0

24.0

31.0

35.0

39.5

44.5

55.0

63.0

74.0

78.0

88.0

96.0

21.0

21.0

23.0

25.0

27.8

27.8

32.0

32.0

32.0

38.5

38.5

43.0

48.0

48.0

52.0

56.0

59.0

67.5

80.0

85.0

90.0

108.0

117.0

127.0

24.0

24.0

26.0

29.0

31.8

31.8

36.5

36.5

36.5

44.0

44.0

48.5

53.0

53.0

58.0

64.0

67.0

77.0

92.0

98.0

113.0

122.0

131.0

148.0

5/8”

5/8”

3/4”

3/4”

3/4”

1”

1”

3/4”

1”

1”

1-1/4”

1-1/4”

1-1/2”

1-1/4”

1-1/2”

2”

2”

2”

2-1/2”

3”

3-1/4”

3-1/2”

4"

41/2"

25.0

25.0

22.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

15.0

20.0

20.0

20.0

20.0

20.0

20.0

20.0

25.0

25.0

25.0

25.0

25.0

25.0

8.0

10.0

11.0

12.5

13.5

13.5

18.5

18.5

20.5

23.5

23.5

27.0

30.5

30.5

34.0

37.5

41.5

46.5

52.5

60.5

67.5

78.5

84.0

93.0

13.0

14.0

15.0

16.5

18.5

18.5

20.0

20.0

23.0

26.5

26.5

30.0

33.5

33.5

37.0

41.0

46.0

52.0

60.0

67.0

78.0

83.0

93.0

102.0

INSTALLATION INSTRUCTIONS:• Pass the compression nut (Pt.1), Washer No.

1(Pt.3) in succession order over the cable before commencing to strip the cable.

• Remove the outer sheath to the desired length depending on the length of leads required. Pass the rubber ring (Pt.4) over the armouring upto the outer sheath.

• Pass the 2nd washer (Pt.5) over the armouring and splay out the armour wire one by one and then cut the armour wires according to the sizes of washer. Pass the third washer (Pt.6). File the sharp edges of armour wires and bend them so that the armour wires are now secure between the two washers.

• Push the assembly through gland body (Pt.2) and tighten the compression nut. While doing so the rubber ring will expand in radial direction and will grip the cable. This will also ensure dust proof entry of the cable.

A-1

B-1

D-3

L-9

M

L-10

FU

NC

TIO

NA

L D

ES

IGN

D Across Corner

D-3

E

GLAND REF. E D-3 D-3A D L-9 L-10 MRUBBER REF. A-1 B-1 C-1

SIBG-1216

SIBG-1616

SIBG-1619

SIBG-2119

SIBG-2125

SIBG-2925

SIBG-2932

SIBG-2938

SIBG-3632

SIBG-3638

SIBG-4238

SIBG-4251

SIBG-5451

SIBG-5463

SIBG-6063

SIBG-6675

SIBG-7882

SIBG-8490

SIBG-9210

SIBG-1011

SIBG-1525

12

16

19

19

25.4

25.4

32

38

32

38

38

51

51

63.5

63.5

76

83

90

100

110

125

16

19

19

24

24

33

33

33

41

41

47

47

56

56

64

68

82

91

98

107

118

12

12

15

15

21

21

27

32

26

32

32

44.5

44.5

55

55

66

72

81

91

100

113

25.5

29.5

29.5

36.5

36.5

47

47

47

59

59

71

71

80

80

92

100

116

124

135

146

164

15

15

15

18

18

21

21

21

22.5

22.5

26

26

27

27

31

33

33

30

32

32

32

9

9.5

9.5

9.5

9.5

10

10

10

11

11

12

12

12

12

12

13

14

19

20

25

25

3

3.5

3.5

3.5

3.5

4

4

4

4.5

4.5

5.5

5.5

6

6

6.5

7

8

8

8

9

10

R1212

R1611

R1613

R1615

R2116

R2118

R2120

R2921

R2923

R2925

R2927

R2929

R3631

R3633

R3635

R3637

R4236

R4238

R4240

R4242

R5444

R5446

R5448

R5450

R6053

R6055

R6058

R6060

R6662

R6664

R6668

R7870

R7874

R7877

R8484

R9292

R1100

R1115

12

11

13

15

16

18

20

21

23

25

27

29

31

33

35

37

36

38

40

42

44

46

48

50

53

55

58

60

62

64

68

70

74

77

84

92

100

115

18

20.5

20.5

20.5

26

26

26

35

35

35

35

35

45

45

45

45

52

52

52

52

59

59

59

59

68

68

68

68

72

72

72

88

88

88

97

105

114

127

8

9

9

9

11

11

11

12

12

12

12

12

14

14

14

14

17

17

17

17

18

18

18

18

18

18

18

18

18

18

18

20

20

20

20

20

20

20

Installation Instructions:Remove the outer sheath to the desired length depending on the length of the leads required, and splay out the armour wire one by one and then cut the same according to the size of armour clamping cone. File the sharp edges of the armour wire and fit the gland as per assembly shown sectionally.

Parts1. Skid Washer2. Outer Seal3. Sealing Nut4. Brass Body5. Clamping Ring

6. Armour Clamp7. Inner Seal8. Gland Barrel9. Flat Washer10.Check Nut

C A B E

D

123456789

10

Page 32: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

FLANGE TYPE CABLE GLANDSBraco Flange Type Cable Glands are made out of brass castings and are machined accurately to the required sizes. These glands are suitable for armoured calbes and are called mechanical glands hence suitable for outdoor application.

The gland comprises of brass body (flange type oval shape) and plate clamped with galavanised mild steel studs and nuts for clamping the armour. Tapered cone and nut are provided for termination of cable.

The cone and body taper is designed for giving a firm grip to the armour of the cable.

FL 5

FL 4

FL 3

FL 2

FL 1

FL 11

FL 0

FL 00

FL 38

FL 001

FL 002

FL 003

FL 0033

FL 004

FL 005

15.0

19.0

19.5

25.0

31.0

31.0

37.5

37.5

42.0

49.0

53.5

60.0

65.0

75.0

99.0

16.5

19.0

20.5

24.5

30.0

34.0

35.0

38.0

42.0

44.0

52.0

58.0

67.0

76.0

83.0

10.0

13.5

13.0

19.0

25.5

28.0

29.5

29.5

34.5

41.0

46.0

52.0

56.0

65.2

88.0

13.0

13.0

13.0

16.5

15.5

15.0

21.0

20.0

21.5

20.5

21.5

23.0

25.5

22.5

22.5

12.0

15.0

18.5

20.5

24.0

29.5

32.5

34.5

37.0

40.5

43.5

51.0

56.5

66.0

75.0

16.5

19.0

20.5

24.5

30.0

34.0

35.0

38.0

42.0

44.0

52.0

58.0

67.0

76.0

83.0

Code No E(mm) Max Dia Of Cable

Under Armour Dia L

Acceptance Dia

Min Max

DOUBLE COMPRESSION GLANDS ( Flame Proof )

BPF 3/8' 11 21.0 24.0 5/8" 12 8.0 12.0BPF 1/2" 11 21.0 24.0 5/8" 12 8.0 13.0BPF 5/8" 14 23.0 26.0 3/4" 15 11.0 15.0BPF 001 14 25.0 29.0 3/4" 15 12.5 16.5BPF 1" 19 30.0 34.0 1" 15 20.0 23.0BPF-001S 12 21.0 24.0 3/4" 15 8.0 12.5BPF-01S 15 25.0 29.0 3/4" 15 12.5 16.5BPF 01 13 28.0 32.0 3/4" 15 15.0 18.0BPF 01L 15 28.0 32.0 1" 15 15.0 18.0BPF 02 15 32.0 36.5 1" 15 18.0 20.0BPF 02S 14 32.0 36.5 3/4" 15 18.0 20.0BPF 03 18 32.0 36.5 1" 15 20.0 23.0BPF 04 20 38.0 44.0 1" 15 23.0 26.0BPF 04L 24 38.0 44.0 1-1/4" 15 23.0 26.0BPF 05 24 41.0 47.0 1-1/4" 15 26.0 30.0BPF 05L 26 41.0 47.0 1-1/2" 15 26.0 30.0BPF 06 31 47.0 53.0 1-1/2" 15 30.0 33.0BPF 06S 24 47.0 53.0 1-1/4" 15 30.0 33.0BPF 07 32 52.0 58.0 1-1/2" 15 33.0 37.0BPF 08 38 56.0 64.0 2" 15 37.0 41.0BPF 09 39 59.0 67.0 2" 15 41.0 46.0BPF 010 44 67.5 77.0 2" 20 46.0 52.0BPF-010L 50 67.5 77.0 2-1/2" 20 46.0 52.0BPF 011 56 80.0 92.0 2-1/2" 20 52.0 60.0BPF 012 64 85.0 98.0 3" 20 60.0 66.0

Flamerproof Braco Cat.

No. AA/FE

A/C E1

Nipple thread Inch D Above Upto

Cable OD (mm)

Braco Double Compression glands are manufactured out of brass rods/castings and are machined accurately to the required sizes. These are nickel plated to avoid corrosion whilst storage and use.

These glands have two moisture proof seals and may be used under most climatic conditions. These are weather proof and waterproof and when protected by a PVC shroud these can be used under most corrosive conditions. The armour cone and ring gives excellent mechanical and electrical connections.

These glands are as per BS6121 1973 and have ten parts: Brass Body, Armour Clamp and Ring, Gland Barrel sealing nut, two pcp seals, the skid washer check nut and flat washer between the gland barrel and check nut is provided to prevent the drag on outer seal. The detail parts are shown in functional drawing.

These glands are available in various different sizes and are suitable for all cables up to 1000 sq.mm. and control cables up to 61 cores. The entry threads on gland barrel are normally threaded according to IS 1653 (Steel conduits for electrical wiring), however if any special kind of gland or thread is required, the same can be supplied on request.

The gland can also be supplied with any other special plating such as cadmium, tin or pasivated. Also the glands can be supplied made out of aluminium, mild steel or stainless steel.

C A B E

D

123456789

10

Parts1. Skid Washer2. Outer Seal3. Sealing Nut4. Brass Body5. Clamping Ring

6. Armour Clamp7. Inner Seal8. Gland Barrel9. Flat Washer10.Check Nut

Certified by : Certificate No.:

Central Institute of Mining & Fuel Research CIMFR/TC/P/H675

SECTION A-A

L

E

Page 33: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco BW Brass cable glands are as per BS 6121 Part 1:1989 and suitable for single wire armoured plastic or rubber sheathed cables. These glands provide mechanical cable retention, and electrical continuity via armour wire termination. The use of these glands is recommended in dry, indoor situations. Shrouds may be used for ingress protection.

BW Type Cable Glands

GLANDSIZE

ENTRY THREAD CABLE ACCEPTANCE DETAIL

DIA.

C

20 S

20 L

25 S

25 L

32 S

32 L

40 S

40 L

50 S

50 L

63 S

63 L

75 S

75 L

90 L

20

20

25

25

32

32

40

40

50

50

63

63

75

75

90

9

9

9

10

10

10

11

11

13

13

14

14

15

15

20

11.60

14.00

19.00

20.00

24.00

26.20

30.00

32.50

40.00

44.00

51.00

55.00

62.00

67.00

79.00

16.00

20.00

24.00

27.00

30.50

33.00

37.00

41.00

47.50

52.60

60.00

66.00

72.00

78.00

90.00

0.9/1.25

0.9/1.25

1.25/1.60

1.25/1.60

1.60/2.00

1.60/2.00

1.60/2.00

1.60/2.00

2.00/2.50

2.00/2.50

2.50

2.50

2.50

2.50

2.50/3.15

21.50

24.20

30.00

30.00

36.50

36.50

44.50

46.50

55.00

59.00

69.00

73.00

83.00

86.30

105.00

24.50

27.30

33.60

34.40

40.00

42.30

50.00

52.00

62.00

66.00

76.00

82.00

94.00

98.00

118.00

LENGTHMINIMUM

E

DIAMAX.

A

DIAMAX.

B

ARMOURDIAMETER

D

ACROSSFLAT

ACROSSCORNER

E

BC A

D

CW Type Cable GlandsBraco CW Brass cable glands are as per BS 6121 Part 1 :1989 and suitable for single wire armoured plastic or rubber sheathed cables. The outer seal grips sheath. These glands provide mechanical cable retention, and electrical continuity via armour wire termination. The use of these glands is recommended in indoor as well as outdoor application because of suitability in most climatic conditions weather proof and water proof.

GLANDSIZE

ENTRY THREAD CABLE ACCEPTANCE DETAIL

DIA.

C

20 S

20 L

25 S

25 L

32 S

32 L

40 S

40 L

50 S

50 L

63 S

63 L

75 S

75 L

90 L

20

20

25

25

32

32

40

40

50

50

63

63

75

75

90

10

10

10

10

10

10

11

11

13

13

14

14

15

15

20

11.60

14.00

19.00

20.00

24.00

26.20

30.00

32.50

40.00

44.00

51.00

55.00

62.00

67.00

79.00

16.00

20.00

24.00

27.00

30.50

33.00

37.00

41.00

47.50

52.60

60.00

66.00

72.00

78.00

90.00

0.9/1.25

0.9/1.25

1.25/1.60

1.25/1.60

1.60/2.00

1.60/2.00

1.60/2.00

1.60/2.00

2.00/2.50

2.00/2.50

2.50

2.50

2.50

2.50

2.50/3.15

22.00

25.40

30.00

33.00

38.00

40.00

44.50

46.50

55.00

59.00

69.00

73.00

83.00

87.60

105.00

25.00

28.50

33.60

37.00

43.00

45.00

50.00

52.00

62.00

66.00

76.00

82.00

94.00

99.00

118.00

LENGTHMINIMUM

E

DIAMAX.

A

DIAMAX.

B

ARMOURDIAMETER

D

ACROSSFLAT

ACROSSCORNER

BC A

E

D

Page 34: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

A2 Type GlandsBraco A2 type brass cable glands are as per BS 6121 Part 1:1989 and suitable for unarmoured, plastic or rubber sheathed cables. These glands provide outer seal joint and are suitable for indoor as well as outdoor applications.

C

ENTRY THREAD

16L

20S

20L

25S

25L

32S

32L

40S

40L

50S

50L

63S

63L

75S

75L

90L

GLANDSIZE

DIAMAX.

B

ACROSSFLAT

16

20

20

25

25

32

32

40

40

50

50

63

63

75

75

90

12

12

12

15

15

15

15

20

20

20

20

20

20

20

20

20

E

3.50 - 9.00

8.00 - 11.70

11.00 - 14.00

12.00 - 17.00

13.00 - 20.70

16.50 - 23.00

19.00 - 26.30

23.00 - 29.00

25.00 - 33.00

31.50 - 38.20

36.50 - 44.00

42.50 - 50.00

48.00 - 56.00

54.50 - 62.00

60.50 - 68.00

66.00 - 77.00

21.00

22.00

24.00

27.00

30.00

37.00

41.00

45.00

46.00

58.00

62.00

69.00

73.00

82.00

88.00

103.00

24.00

25.00

26.60

30.50

33.30

41.00

45.50

50.00

51.00

64.00

69.00

76.00

81.00

91.00

97.00

114.00

LENGTHMINIMUM

DIA. ACROSSCORNER

G

H

Braco E1W type brass glands are as per BS 6121 part I :1989 suitable for indoor as well as outdoor applications. These glands are suitable for all types of SWA cable, providing environmental seal on both the cable inner and outer sheaths. The glands also provide mechanical cable retention and electrical continuity via armour wire termination.

GLANDSIZE

ENTRY THREAD CABLE ACCEPTANCE DETAIL

DIA.

C

20 S

20 L

25 S

25 L

32 S

32 L

40 S

40 L

50 S

50 L

63 S

63 L

75 S

75 L

90 L

20

20

25

25

32

32

40

40

50

50

63

63

75

75

90

10

10

10

10

10

10

15

15

15

15

15

15

17

17

20

8.00 - 11.80

11.00 - 14.00

12.00 - 17.00

13.00 - 20.30

17.00 - 24.00

19.00- 26.20

23.00 - 30.00

25.00 - 32.20

31.50 - 38.20

36.50 - 44.00

42.50 - 50.00

49.10 - 56.00

54.50 - 62.00

60.50 - 68.00

66.00 - 79.00

12.90 - 17.20

15.50 - 20.80

17.50 - 24.00

24.00 - 27.20

25.00 - 31.00

26.70 - 34.00

31.00 - 38.50

33.00 - 40.50

39.40 - 46.80

45.70 - 53.20

52.10 - 59.00

58.40 - 66.00

64.80 - 72.00

71.10 - 78.00

77.00 - 90.00

0.90/1.25

0.90/1.25

1.25/1.60

1.25/1.60

1.60/2.00

1.60/2.00

1.60/2.00

1.60/2.00

2.00/2.50

2.00/2.50

2.50

2.50

2.50

2.50

2.50/3.15

24.00

27.70

31.50

35.00

43.00

43.00

51.50

51.50

58.50

66.00

72.00

80.00

86.50

94.00

106.00

27.00

31.00

35.00

39.00

47.50

47.50

57.00

57.00

65.00

73.00

80.00

89.00

97.00

105.00

118.00

LENGTHMINIMUM

E

DIAMAX.

A

DIAMAX.

B

ARMOURDIAMETER

D

ACROSSFLAT

ACROSSCORNER

BRACO E1W TYPE GLANDS

ED

C A B

C B

E

Page 35: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

PVC SHROUDSBraco black Polyvinyl chloride PVC shrouds are used for fitting over cable glands where additional protection against generous weather conditions and corrosion is required. They provide an effective seal onto both gland and cable oversheath as well as fast and simple installation. PVC shrouds also enhance the IP rating of a termination.

These shrouds are use to minimize the risk of dirt or foreign substances gathering on the cable gland body and or point of cable to gland interface.

DIA A DIA B

Braco earth tags are made out of brass sheets and punched to the required sizes and are suitable for all sizes of cable glands. Electrical continuity is normally achieved via the screwed entry into metal boxes. For clearance Hole entry situations it is essential to obtain direct metal-to-metal contact between the gland, earth tag and the enclosure. These are used to ensure earth continuity between the gland and the equipment.

Earth Tags

CatNo.

Dia A(mm)

Dia B(bolt Hole)

Thickness(mm)

Short CircuitRating KA

ET -20

ET -25

ET -32

ET -40

ET -50

ET -63

ET -75

20.3

25.8

32.4

40.4

51.2

63.9

76.6

6.7

6.7

12.4

13.2

13.2

13.2

13.2

1.5

1.5

1.5

1.5

1.5

1.5

1.5

4.4

4.0

6.2

9.8

11.4

12.0

14.3

DI A A

DI A B

Page 36: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Braco gland kits contain all that is necessary for terminating a cable Gland(s), Earth tag(s), locknut(s) and shroud(s). Since the kits are ready to use hence are convenient and help to keep all parts for each termination together. The kits are easier to stock than loose pieces.

Kits

TAILOR MADETAILOR MADETAILOR MADETAILOR MADE

Page 37: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Nominal Area2mm

Aluminium Stranded Wire Dia with Equivalent solid cross section

Cable size

Dia. of Cond.

Solid CrossSec. Dia.

4

4.5

6

6.75

10

16

25

35

50

70

95

120150

185240

300400

5006258001000

1/2.247/.851/2.367/.921/2.87/1.061/2.97/1.121/3.557/1.351/4.57/1.73/37/2.2419/1.323/3.53/3.667/2.519/1.57/2.87/319/1.87/3.17/3.47/3.657/3.7819/2.247/4.177/4.3919/2.537/1.837/2.0619/337/2.2437/2.537/361/2.2461/2.561/391/2.3691/2.6591/391/2.3591/3.75

2.242.552.362.762.83.182.93.363.554.084.55.16.466.726.67.27.97.57.58.4999.310.210.9811.3411.212.5113.1712.512.614.421515.6817.52120.1622.5272629.153336.941.5

2.242.242.362.362.82.82.92.93.553.64.54.55.25.85.85.86.56.56.57.488899.7109.61111.510.910.912.41313.515.317.517.519.522.522.525.228.231.935.5

0.0010.0015-0.002-0.0030.003--0.0045--0.007--0.010.0145-0.0225-0.030.04--0.06-0.0750.1-0.12-0.15-0.20-0.25-0.3-0.4-0.50.6-0.750.851.0

1/.0361/.0441/.044093/.0291/.05513/.0361/.0641/.07093/.04177/.0297/.03351/.08827/.0367/.04171/.11027/.0447/.0527/.05517/.0647/.066919/.04419/.0527/.08827/.098419/.06419/.070919/.07219/.08319/.088237/.06419/.098437/.07237/.081137/.08337/.088237/.09337/.098437/.10361/.088261/.09361/.098461/.10391/.09361/.118191/.103127/.093127/.103

1/.9141/1.121/1.123/.7371/1.403/.9141/1.631/1.803/1.067/.7377/.8501/2.247/.9147/1.061/2.807/1.127/1.327/1.407/1.637/1.7019/.1.1219/1.327/2.247/2.5019/1.6319/1.8019/1.8319/2.1119/2.2437/1.6319/2.5037/1.8337/2.0637/2.1137/2.2437/2.3637/2.5037/2.6261/2.2461/2.3661/2.5061/2.6291/2.3661/3.0091/2.62127/2.36127/2.62

0.0360.0440.0440.0620.0550.0780.0640.0710.0900.0870.1000.0880.1080.1250.1100.1320.1560.1650.1920.2000.2200.2600.2650.2950.3200.3540.3600.4150.4410.4480.4920.5040.5680.5810.6170.6510.6890.7210.7940.8370.8860.9271.0231.0631.1331.2091.339

0.911.121.121.591.401.971.631.802.282.212.552.242.743.182.803.353.964.204.885.105.596.606.727.508.139.009.1410.511.211.412.512.814.4214.815.6816.517.518.320.1521.322.523.526.027.028.830.734.0

--1.0-1.5--2.52.5-4.04.0-6.06.0--10-16--2535-50--70-95-120-150-185-240-300--400---

Solid and Stranded Conductors Annealed CopperNominal

AreaStranding and Wire Diameter

Appx. overall(Eqvt.) Dia.

2Inch 2mm Inch mm Inch mm

Page 38: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

AWG(B7S)

Conversion table for the most important foreign wire gauges to metric units

NBSInchesSWG

Area2mm

Nominal2Inch

Cond. Dia.mm

-8--7-6--5--4--3--2--1--1/0--2/0--3/0-4/0---------

10--9-8--7-6--5--43-2--11/0-2/0--3/04/0-5/0-6/07/0-------

--7/.052”----7/.064”---19/.044”--19/.052”-----19/.064”-----19/.083”--------37/.072”37/.083”37/.103”61/.093”61/.103”91/.103”127/.103”

--0.00145----0.0225---0.03--0.04-----0.06-----0.1--------0.150.20.30.40.50.751.0

8.308.379.3510.5110.5512.9713.3014.5215.7016.7718.6819.3521.1522.7725.8126.6727.2732.1833.6338.6038.7142.4145.6053.1953.4861.3664.5267.4370.1281.0785.394.56107.2109.1126.796.77129.03193.55258.06322.58483.87645.16

3.33.34.03.73.74.14.14.94.54.64.95.65.25.46.65.85.96.46.57.08.17.47.68.28.38.810.59.39.510.210.411.011.711.812.712.814.818.321.323.628.834.0

AWG(B7S)

Conversion table for the most important foreign wire gauges to metric units

NBSInchesSWG

Area2mm

Nominal2Inch

Cond. Dia.mm

28-27-26-25--24-23-22-2120---19--18-17--16-15---1413----1211--10--9-

-29-28-27-2625-24-23-22--21---2019---18--17---16--15-14--13--12--11

------------------1/.036”3/.029”----1/.044”--3/.029”---1/.064”3/.036”----7/.029”----7/.36”--7/.044”--

------------------0.0010.001----0.0015--0.002---0.0030.003----0.0045----0.007--0.01--

0.080.090.100.110.130.140.160.160.200.200.250.260.290.330.400.410.520.520.650.650.650.660.810.820.971.041.171.291.311.591.651.941.942.082.082.622.632.903.243.314.174.294.525.265.486.456.636.82

0.30.40.40.40.40.40.50.50.50.50.60.60.60.60.70.70.80.80.91.10.90.91.01.01.11.21.21.61.31.41.51.42.01.61.61.81.82.22.02.12.32.32.72.62.63.42.92.9

Area2mm

Cond’ Dia’ mm

MCM

250

300

350

400

450

500

550

600

650

700

750

800

850

900

1000

127

152

177

203

228

253

279

304

329

355

380

405

431

456

507

14.6

16.0

17.3

18.5

19.6

20.7

21.7

22.7

23.6

24.5

25.4

26.2

27.0

27.8

29.3

Area2mm

Nominal2Inch

No. and Dia.of strands NBS

Conversion table for the most important foreign wire gauges to metric units

Cond’Dia’ mm

14/.0076”

23/.0076”

40/.0076”

70/.0076”

110/.0076”

162/.0076”

0.0006

0.001

0.0017

0.003

0.0048

0.007

0.39

0.65

1.10

1.94

3.10

4.52

0.9

1.2

1.5

2

2.3

3.1

*Applies only to Multistrand Conductors ACC, to ASTM Stranding Class A,Multistrand construction specified in VDE 0250 table

1 MCM - 1000 CM21 Cm - 1 CIRCULAR MIL = 0.000507 mm

1 CIRCULAR NIL = AREA OF A CIRCLE1 MIL IN DIA’

NominalArea

2In

Copper Cable Stranded and Multistrand Wire with Equivalent solid sectionDiameter & Bare Conductor Diameter

NominalArea

2mm

Cable size

2In

Diam’ ofCond’mm

Solid CrossSect.

Dia. mm.0.0025

0.003

0.004

0.0045

0.015

0.023

0.039

0.065

0.100

0.150

0.175

0.185

0.200

0.230

0.288

0.350

0.420

0.620

40/.0076

27/.0118

70/.0076

45/.0118

144/.0118

91/.018

127/.020

248/.018

416/.018

610/.018

550/.020

427/.0236

810/.018

650/.020

525/.0236

665/.0236

760/.0236

1325/.020

1925/.026

1.6

1.8

2.3

2.6

4.2

5.1

6.5

8.5

12.5

15.3

15.6

16.5

16.2

16.2

18.5

20.3

21.8

22.5

29.5

1.3

1.5

1.7

1.9

3.6

4.54

5.7

7.4

9.2

11.3

12.0

12.4

13.0

13.0

13.8

15.4

16.5

18.5

22.4

1.5

2

2.5

3

10

15

25

42

70

100

112

120

133

150

185

225

270

400

Page 39: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

Decimal MillimetersFraction

1/641/323/641/165/643/327/641/89/645/3211/643/1613/647/3215/641/417/649/3219/645/1621/6411/3223/643/825/6413/3227/647/1629/6415/3231/64½33/6417/3235/649/1637/6419/3239/64

0.0150.0310.0460.0620.0780.0930.1090.1250.1400.1560.1710.1870.2030.2180.2340.2500.2650.2810.2960.3120.3280.3430.3590.3750.3900.4060.4210.4370.4530.4680.4840.5000.5150.5310.5460.5620.5780.5930.609

0.40.81.21.62.02.42.83.23.64.04.44.85.25.66.06.36.77.17.57.98.38.79.19.59.910.310.711.111.511.912.312.713.113.513.914.314.715.115.5

Equivalents of an inch

Area2mm

Cond. Dia. mmMCM

Equivalents of an inch

5/841/6421/3243/6411/1645/6423/3247/643/449/6425/3251/6413/1653/6427/3255/647/857/6429/3259/6415/1661/6431/3263/641

0.6250.6400.6560.6710.6870.7030.7180.7340.7500.7650.7810.7960.8120.8280.8430.8590.8750.8900.9060.9210.9370.9530.9680.9841.000

15.916.316.717.117.517.918.318.619.019.419.820.220.621.021.421.822.222.623.023.423.824.224.625.025.4

Nominal Area2mm

Copper Stranded Multistrand Wire sizes in mm with Equivalent solid cross sectionDiameter & Bare Conductor Diameter

Cable sizemm

Dia. of Cond.

Solid CrossSec. Dia.

1.5

2.5

4

6

10

1516

25

35

42

1/1.387/.5221/.330/.25189/.11/1.787/.6735/.350/.25315/.11/2.2619/.5256/.3511/.11/2.767/1.0519/.6485/.3756/.11/3.557/1.3519/.849/.5180/.41197/.191/.4571/4.527/1.737/.7549/.65127/.42058/.17/2.1337/.984/.62200/.4796/.23185/.119/1.5337/1.1133/.56285/.41115/.24459/.1248/.457

1.381.61.71.61.91.782.02.22.12.22.262.62.832.763.23.23.53.73.554.14.34.65.04.55.14.525.15.35.466.86.46.87.77.57.68.37.68.38.78.7910.28.5

1.381.381.381.381.381.781.81.81.81.82.262.262.262.262.762.82.82.82.83.63.63.63.63.63.64.44.54.54.54.54.54.55.75.75.75.75.75.76.76.76.76.76.76.77.4

Nominal Area2mm

Copper Stranded Multistrand Wire sizes in mm with Equivalent solid cross sectionDiameter & Bare Conductor Diameter

Cable sizemm

Dia. of Cond.

Solid CrossSec. Dia.

50

64.570

95

100112120

133

150

185240270300

400

19/1.8361/1133/.69400/.41591/.2416/.45719/2.2461/1.2189/.69560/.419/2.5261/1.4259/.69485/.51936/.25610/.457550/.537/2.0361/1.6336/.67614/.52445/.25810/.457659/.537/2.26392/.69765/.537/2.6261/2.361325/.561/2.5790/.691530/.51925/.5

9.29.710.41110.912.511.211.612.712.812.613.514.514.914.915.315.614.215.516.41616.416.216.215.81819.218.421.322.522.5252729.5

8888889.29.59.59.5111111111111.31212.412.412.412.412.4131313.813.813.815.417.518.520202022.4

Page 40: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

BRASS GLANDSBRASS GLANDSBRASS GLANDS

Braco Corrosion Inhabiting Compound is recommended for crimping connections. It is suggested where conditions are particularly aggressive such as chemical or salt-laden atmospheres or where inspection and cleaning are not regular.

Braco Corrosion Inhabiting Compound is mixture of Grey Lithium based grease with abrasive particles and suspended Zinc particles, which assist in jointing because as metal flows under pressure the abrasive particles cause small area of cold welding :

• Corrosion Inhibitor does not affect the electrical properties of the compression joint.

• It is non-corrosive to aluminium, copper, steel, tin, zinc and combination of thes metals.

• It does not deteriorate on exposure to a tmosphere a t conductor operat ing temperature.

• It has good sealing properties against moisture and contaminating substances in the atmosphere It has high temperature drop point.

The mixture contains :1. Grey Lithium based grease 85%2. Zinc Chromate 5%3. Titanium Dioxide 10%

At 700 Amp atAmbient Temp.

After 10 days 6.16mVo3.1mV 5.35mV at 90 c

After 1/2 hour ageing0 ndat 200 C after 2 test

Joint withoutCompound

4.42 mV

5.70 mV

7.06 mV

Joint with BracoCompound

2.65 mV

2.97 mV

3.55 mV

Joint with ImportedCompound

3.85 mV

4.75 mV

5.56 mV

Specification

Test Report

The test carried out on 200 mm conductor joined with Aluminium lugs 95 Sq. mm. The test results found in terms of mV drop compared to joint with nonuse of compound, joint with Braco Compound and joint with imported compound

CORROSION INHABITING COMPOUND

BRASS GLANDS

Page 41: Гидра зеркала официальная ссылкаrujutaent.com/wp-includes/pdf/braco_cat.pdf · 2019. 11. 4. · Maximum achieved with fittings efficiency accurate Braco

INTRODUCTION OF BRACO CABLE GLANDS

FUNCTIONS OF CABLE GLANDS²

²

²

²

²

²

SELECTION GUIDELINES

Braco Cable Glands are mechanical cable entry devices, which are constructed from metallic materials and are used throughout all industries in conjunction with cable and wiring used in the electrical control panels, instrumentation and automation systems.

Cable Glands may be used on all types of electrical power, control, instrumentation, data and telecommunications cables. They are used as a sealing and terminating device to ensure that the characteristics of the enclosure which the cable enters can be maintained adequately.

Cable Glands may provide environmental protection by sealing on the outer cable sheath, excluding dust and moisture from the electrical or instrument enclosure.

Cable Glands may facilitate earth continuity in the case of armoured cable when the cablegland has a metallic construction.

Cable Glands may provide a holding force on the cable to ensure adequate levels of cablepull out resistance.

Cable Glands may provide additional sealing on the part of the cable entering the enclosure, when a high degree of ingress protection is required.

. Cable Glands may provide additional environmental sealing at the cable entry point,maintaining the ingress protection rating of the enclosure with the selection of applicableaccessories dedicated to performing this function.

When used in hazardous areas they are required to maintain the level of protection of theequipment to which they are attached.

There are many factors to consider when selecting cable glands for industrial installations. Neglecting to pay due attention to some of these factors may cause unnecessary anxiety at a future point in time when the equipment and cables have been delivered on site, but for example the cable glands have either been forgotten to be ordered or it is discovered that they are the incorrect type or size at the very point when they are needed the most. Good advice would be to allocated some value added planning and preparation time to the subject of cable gland selection so as to avoid the great inconvenience which is likely to occur at a critical point in time. In the event that a user or contractor is in possession of a cable schedule that requires a cable gland selection and sizing process to be carried out Braco products would be blissful to assist in carrying out this process.

While selecting cable glands the following aspects shall be carefully considered:

• Identify the type of cable to be used.• Check the construction, size and material properties of the cable.

If the cable is armoured, verify the following:

²

²

²

²

²

²

²

²

²

²

²

²

²

Check the type and material of the cable armour.

Check the short circuit fault current rating of the cable armour.

Check the actual diameter of the inner bedding.

Check the actual diameter of the lead covering.

Check the actual size of the overall cable diameter.

Check the size and type of armour or braid.

Check any special environmental requirements in relation to corrosion protection.

Check whether any protective plating is required to be applied on the cable gland.

Check the type and size of the cable entry hole in the matching electrical equipment.

Check whether an entry thread seal is required.

Check whether fixing accessories such as locknuts and serrated washers are required.

Check whether earth tags are required.

Check whether shrouds tags are required.

Though the information presented in Gland Selection Chart is intended to assist users to ensure that the correct cable gland is selected. It is the responsibility of the user to ensure that the cable gland selected is of the correct size and type to suit the type of cable being terminated.

While terminating cables and wires during the process of installation of electrical equipment this should be done by qualified and competent personnel in line with good engineering practice, observing safe electrical practices. It is also important that the correct cable entry device or cable gland is also important that the correct cable entry device or cable glands is selected to suit the cable being used. For instances using normal unarmoured cables, the cable would usually be fed through a cable entry device that has a sealing ring activated onto the cable outer sheath. The choice of cable glands to suit this unarmoured cable may need to take into account any vulnerability of the cable, may need to take into account any vulnerability of the cable, which may be especially critical if the cable is an instrument cable. Two factors which could affect the long term cable performance are the type and design of the cable gland sealing function, and the possibility of this being inadvertently or otherwise over tightened onto the cable sheath.