SS-GSZ14 www.goodmanmfg.com 4/17Supersedes 1/17
Energy-Efficient Split System Heat Pump
Up to 15 SEER & 9.0 HSPF1½ to 5 Tons
Cooling Capacity: 18,000 to 60,000 BTU/hHeating Capacity: 18,000 to 60,000 BTU/h
GSZ14
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.
Standard Features Cabinet Features• High-efficiency scroll compressor• SmartShift® technology to
ensure quiet reliable defrost• Factory-installed bi-flow liquid-line filter drier• Factory-installed suction-line accumulator• Factory-installed compressor crankcase heater• Factory-installed high-capacity muffler• High- and low-pressure switches• Service valves with sweat connections
and easy access to gauge ports• Copper tube/enhanced aluminum fin coil• Fully charged for 15’ of tubing length• Contactor with lug connection• Ground lug connection• AHRI Certified; ETL Listed
• Goodman® brand sound control top design• Steel louver coil guard• Heavy-gauge galvanized-steel cabinet• Attractive Architectural Gray powder-paint
finish with 500-hour salt-spray approval• Top and side maintenance access• Service ports and controls are
accessible while unit is operating• When properly anchored, meets the 2010
Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov.
ContentsNomenclature ........................................ 2Product Specifications ........................... 3Expanded Cooling Data ......................... 5Expanded Heating Data ....................... 29Performance Data ............................... 32AHRI Ratings ........................................ 34Wiring Diagram .................................... 51Dimensions .......................................... 52Accessories .......................................... 52
2 www.goodmanmfg.com SS-GSZ14 SS-GSZ14 www.goodmanmfg.com 3
Nomenclature
G S Z 14 036 1 AA
1 2 3 4,5 6,7,8 9 10,11
Brand Engineering *
G Goodman® Brand Major & Minor revisions* Not used for inventory control.
Product Category
S Split System Electrical
1 - 208/230 V, 1 Phase, 60 Hz
Unit Type
X Condenser R-410A Nominal Capacity
Z Heat Pump R-410A 018 - 1½ tons 042 3½ Tons
024 - 2 tons 048 4 Tons
Efficiency 030 - 2½ tons 060 5 Tons
13 13 SEER 16 16 SEER 036 - 3 tons
14 14 SEER 18 18 SEER
2 www.goodmanmfg.com SS-GSZ14 SS-GSZ14 www.goodmanmfg.com 3
Product Specifications
GSZ140181K*
GSZ140191A*
GSZ140241K*
GSZ140251A*
GSZ140301K*
GSZ140311A*
Nominal Capacities
Cooling (BTU/h) 18,000 17,400 24,000 23,200 30,000 28,000
Heating (BTU/h) 18,000 18,000 24,000 23,200 30,000 31,000
Decibels 72 72 72 72 74 75
CompressorRLA 9.0 9.0 10.9 10.9 13.5 13.5
LRA 47.5 47.5 62.9 62.9 72.5 72.5
Type Scroll Scroll Scroll Scroll Scroll Scroll
Condenser Fan MotorHorsepower 1/6 1/6 1/6 1/6 1/6 1/6
FLA 0.95 1.1 0.95 1.1 0.95 1.10
Refrigeration SystemRefrigerant Line Size¹
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction Line Size (“O.D.) ¾" ¾" ¾" ¾" ¾" ¾"
Refrigerant Connection Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction Valve Size (“O.D.) ¾" ¾" ¾" ¾" ¾" ⅞"
Standard Line Set Length (max. feet) 80 80 80 80 80 80
Long Line Set Length (max. feet) ²
Equivalent Length 250 250 250 250 250 250
Linear Length 200 200 200 200 200 200
Vertical Length (outdoor below indoor) 80 80 80 80 80 80
Vertical Length (outdoor above indoor) 80 200 80 200 80 200
Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 92 92 92 92 95 160
Electrical DataVolts/Phase (60 Hz) 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1
Minimum Circuit Ampacity ³ 12.2 12.4 14.6 14.7 17.8 17.9
Max. Overcurrent Protection ⁴ 20 20 25 25 30 30
Min / Max Volts 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197/253
Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" 1/2" or 3/4"
Unit WeightsEquipment Weight (lbs.) 143 143 143 143 171 186
Ship Weight (lbs) 154 154 154 154 182 206
ENERGY STAR® Certified ^ NO NO NO
^ Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must
be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. See Page 24 for all ENERGY STAR certified combinations
as of this document’s revision date.
¹ Tested and rated in accordance with ARI Standard 210/240² Reference TP-107* for additional application requirements³ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes⁴ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes• Always check the S&R plate for electrical data on the unit being installed.• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.• Installation of these units may require the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT
NOT THE INDOOR COIL.
4 www.goodmanmfg.com SS-GSZ14 SS-GSZ14 www.goodmanmfg.com 5
Product Specifications (cont.)
GSZ140361K*
GSZ140371A*
GSZ140421K*
GSZ140481K*
GSZ140491K*
GSZ140601K*
Nominal Capacities
Cooling (BTU/h) 36,000 33,000 42,000 48,000 48,000 60,000
Heating (BTU/h) 36,000 34,000 42,000 48,000 48,000 60,000
Decibels 74 73 75 75 76 76
CompressorRLA 15.4 14.1 16.7 18.5 19.9 26.4
LRA 83.9 72.2 109.0 124.0 109.0 134.0
Type Scroll Scroll Scroll Scroll Scroll Scroll
Condenser Fan MotorHorsepower 1/6 1/4 1/6 1/4 1/6 1/4
FLA 0.95 1.50 1.1 1.5 1.1 1.5
Refrigeration SystemRefrigerant Line Size¹
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction Line Size (“O.D.) ⅞" ⅞" 1⅛" 1⅛" 1⅛" 1⅛"
Refrigerant Connection Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction Valve Size (“O.D.) ¾" ⅞" ⅞" ¾" ⅞" ⅞"
Standard Line Set Length (max. feet) 80 80 80 80 80 80
Long Line Set Length (max. feet) ²
Equivalent Length 250 250 250 250 250 250
Linear Length 200 200 200 200 200 200
Vertical Length (outdoor below indoor) 80 80 80 80 80 80
Vertical Length (outdoor above indoor) 80 200 80 80 80 80
Valve Connection Type Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 112 175 140 133 187 205
Electrical DataVolts/Phase (60 Hz) 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1 208-230/1
Minimum Circuit Ampacity ³ 20.2 19.1 22.0 24.6 26.0 34.5
Max. Overcurrent Protection ⁴ 35 30 35 40 45 60
Min / Max Volts 197 / 253 197/253 197 / 253 197 / 253 197 / 253 197 / 253
Electrical Conduit Size ½" or ¾" 1/2" or 3/4" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Unit WeightsEquipment Weight (lbs.) 173 220 191 226 273 277
Ship Weight (lbs) 184 240 207 237 288 292
ENERGY STAR® Certified ^ NO NO NO
^ Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must
be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. See Page 24 for all ENERGY STAR certified combinations
as of this document’s revision date.
¹ Tested and rated in accordance with ARI Standard 210/240² Reference TP-107* for additional application requirements³ Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes⁴ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes• Always check the S&R plate for electrical data on the unit being installed.• Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.• Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT
THE INDOOR COIL.
52 www.goodmanmfg.com SS-GSZ14 SS-GSZ14 www.goodmanmfg.com 53
Dimensions
87
56
41
23
86
74
51
23
E D B AC
E D B AC
CO
NFI
DEN
TIA
L PR
OPE
RTY
OF
THE
GO
OD
MA
N M
AN
UFA
CTU
RIN
G C
OM
PAN
Y, L
.P. N
OT
TO B
E D
ISC
LOSE
D T
O O
THER
S, C
OPI
ED, O
R U
SED
FO
R A
NY
PURP
OSE
EXCE
PT A
S A
UTH
ORI
ZED
IN W
RITI
NG
. M
UST
BE
RETU
RNED
UPO
N D
EMA
ND
, ON
CO
MPL
ETIO
N O
F O
RDER
, OR
OTH
ER P
URP
OSE
FO
R W
HIC
H IT
WA
S LE
NT.
CO
MPO
NEN
TS A
ND
MA
TERI
ALS
SPE
CIF
IED
HER
EIN
WIL
L A
LSO
CO
NFO
RM T
O T
HE
APP
LIC
AB
LE S
ECTI
ON
OF
GO
OD
MA
N M
SP 8
24.0
1 W
ORK
MA
NSH
IPST
AN
DA
RD F
OR
FIT
, FEE
L A
ND
FIN
ISH
. S
PEC
IAL
CH
ARA
CTE
RIST
ICS:
=6S
IGM
A
=
CRI
TIC
AL
CH
ARA
CTE
RIST
IC
=
SIG
NIF
ICA
NT
CH
ARA
CTE
RIST
ICSC
CC
6s
ENG
: D
WN
BY:
D
O N
OT
SCA
LE D
RAW
ING AREV
SHT
1 O
F 1
TOLE
RAN
CES
:A
NG
LES
± 1.
5°.X
: ±
.1.X
X : ±
.03
.XXX
: ±
.015
HO
LE Ø
: ±
.005
TUB
E C
UT
LG: ±
.063
DRA
WIN
G T
O B
E IN
TERP
RETE
D IN
AC
CO
RDA
NC
E W
ITH
ASM
E Y1
4.10
0
DIM
ENSI
ON
S A
RE IN
INC
HES
UN
LESS
OTH
ERW
ISE
NO
TED
ECN
REV
DES
CRIP
TIO
NCH
KD
D
ATE
XXXX
XXX
A-
GL
ZON
EXX
XXX
H
WD
Good
man
Man
ufac
turin
g Co
., L.
P.
GSZ1
4
Mod
elDi
men
sion
s
W"
D"H"
GSZ
1401
81/1
91**
2929
34½
GSZ
1402
41/2
51**
2929
34½
GSZ
1403
01**
2929
36¼
GSZ
1403
11A*
35½
35½
34⅝
GSZ
1403
61**
2929
36¼
GSZ
1403
71A*
35½
35½
40
GSZ
1404
21**
35½
35½
39¾
GSZ
1404
81**
2929
36¼
GSZ
1404
91**
35½
35½
34½
GSZ
1406
01**
35½
35½
34½
54 www.goodmanmfg.com SS-GSZ14 SS-GSZ14 www.goodmanmfg.com 55
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
or
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
W
arning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Fai
lure
to d
o so
may
cau
se p
rope
rty
dam
age,
per
sona
l inj
ury,
or d
eath
.⚡
Wiring Diagram
IND
OO
R P
OW
ER S
UPP
LY
NO
TES:
1. T
O IN
DO
OR
UN
IT L
OW
VO
LTAG
E TE
RM
INAL
BLO
CK
& IN
DO
OR
TH
ERM
OST
AT.
2. S
TAR
T AS
SIST
FAC
TOR
Y EQ
UIP
PED
WH
EN R
EQU
IRED
.3.
USE
CO
PPER
CO
ND
UC
TOR
ON
LY.
4. C
RAN
KCAS
E H
EATE
R &
CR
ANKC
ASE
HEA
TER
SW
ITC
H A
RE
FAC
TOR
Y IN
STAL
LED
OPT
ION
.
CR
ANKC
ASE
HEA
TER
MAY
NO
T H
AVE
ADD
ITIO
NAL
GR
OU
ND W
IRE
5. 4
0VA
MIN
IMU
M T
RAN
SFO
RM
ER IS
REQ
UIR
ED.
6. C
OM
MO
N S
IDE
OF
TRAN
SFO
RM
ER M
UST
BE
GR
OUN
DED
.
CO
MP
ALTERNATE DOUBLEPOLE CONTACTOR ONLY
IO
T1
C
MAINR
AUX
5
S
SR
SA
21
RC
CF
SC
T2
C
L1
L2
(IF U
SED
)N
OTE
2CH
CF
MAIN
AUXIO C
M
0140
R00
171
- D
OR
BL/P
KBLR
D
O Y CR
COLO
R CO
DEBK
-----
------
---- B
LAC
KBL
/PK
------
---- B
LUE/
PIN
K ST
RIP
EBR
-----
------
---- B
RO
WN
GR-
------
------
--- G
REE
NO
R --
------
------
- OR
ANG
EPU
-----
------
---- P
URPL
ERD
-----
------
---- R
EDW
H --
------
------
WH
ITE
YL --
------
------
- YEL
LOW
YL/P
K----
------
- YEL
LOW
/PIN
K ST
RIP
E
CO
MPO
NEN
T C
OD
EC
-----
------
---- C
ON
TAC
TOR
CAD
M --
------
CO
MFO
RT
ALER
T D
IAG
NO
STIC
MO
DU
LECC
R --
------
--- C
OM
PRES
SOR
CO
NTA
CTO
R R
ELAY
CH --
------
-----
CRAN
KCAS
E H
EATE
RCH
S ---
------
-- C
RAN
KCAS
E H
EATE
R S
WIT
CH
CM
-----
------
- OU
TDO
OR
FAN
MO
TOR
CM
R --
------
-- C
OND
ENSE
R M
OTO
R R
ELAY
CO
MP
------
-- C
OM
PRES
SOR
CS
------
------
- CO
MPR
ESSO
R S
OLE
NO
IDDC
-----
------
-- D
EFR
OST
CO
NTR
OL
DFT
-----
------
DEF
RO
ST T
HER
MO
STAT
DT
------
------
- DIS
CHAR
GE
THER
MO
STAT
HPS
-----
------
HIG
H P
RES
SUR
E SW
ITC
HH
VDR
-----
--- H
IGH
VO
LTAG
E D
EFR
OST
REL
AYIO
-----
------
--- IN
TERN
AL O
VER
LOAD
LPS
----
------
LO
W P
RES
SUR
E SW
ITC
HLV
DR
-----
---- L
OW
VO
LTAG
E D
EFR
OST
REL
AYLV
JB -
------
-- LO
W V
OLT
AGE
JUNC
TIO
N B
OX
RCC
F ---
------
RUN
CAP
ACIT
OR
FO
R C
OM
PRES
SOR
& F
ANR
VC --
------
--- R
EVER
SIN
G V
ALVE
CO
ILSA
-----
------
-- ST
ART
ASSI
STSC
-----
------
-- ST
ART
CAP
ACIT
OR
FO
R C
OM
PRES
SOR
(OPT
ION
AL)
SR --
------
-----
STAR
T R
ELAY
FO
R C
OM
PRES
SOR
(OPT
ION
AL)
CO
NTR
OLS
SH
OW
N W
ITH
TH
ERM
OST
AT IN
'OFF
' PO
SITI
ON
.
OUT
DO
OR
PO
WER
SU
PPLY
SEE
RAT
ING
PLA
TE
LVJB
CO
NTR
OL
BOX
SC
RD
BL
L2T2
L1T1
C
BKBK
BKR
D RD
BL
RD
RC
CF
YL
BR
PU
RD
SR
5 21
BK YL
BL
IO CM
AUX
MAI
N
BRPU
YL
RD
BK
YL/P
K LPS
DF1 DF2
CH
LVD
R
R
CN
T
DFT
C
Y
DC
DFT
WH
W2
DC
BL/P
K
HPS
O
C
RVC
W2
R
HVD
R
YL/P
K
BK
BK
BL
BLC
HS
R-D
FT
C-R
VLP
S
PS2
O
WC
HPS
CC
R
}FIEL
D L
OW
VOLT
AGE
CO
NN
ECTI
ON
S
RD
BK
CH
SA(IF
USE
D)
NO
TE 2
DFT
RVC
RD
BKBL
/PK
BK
Y
T1 L1
T2 L2
R
DF1
DF2
0
0-RV
C-RV
W
LVDR
HVDR
CCR CNT
0
DFT
R-DF
T
R-PS
1
Y
Y
CR C C
PS2
RD
RD
BK
BK
SEE
NO
TE 4
SEE
NO
TE 5
& 6
BK
BK
RD
SEE
NO
TE 1
EQUI
PMEN
T G
RO
UND
SEE
NO
TE 3
ALTE
RNA
TED
OUB
LE P
OLE
CO
NTA
CTO
R
WH
BKBL
/PK
YL/P
K
YL/P
K
OR
PU
PU
CHS C
R
S
AUX
MAI
N
CO
MP
HF
C
RD
RD
YLYL
GR
USE
N.E
.C. C
LASS
2 W
IRE
SEE
NO
TE 4
RD
R-P
S1
O-R
V
WIR
ING
CO
DE
FAC
TOR
Y W
IRIN
GH
IGH
VO
LTAG
ELO
W V
OLT
AGE
OPT
ION
AL H
IGH
VO
LTAG
E
FIEL
D W
IRIN
GH
IGH
VO
LTAG
ELO
W V
OLT
AGE
SEE
NO
TE 1