defines standard operating procedures to ensure the protection of all employees from respiratory...
TRANSCRIPT
![Page 1: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/1.jpg)
Respiratory Protection Program
![Page 2: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/2.jpg)
Defines standard operating procedures to ensure the protection of all employees from respiratory hazards
Includes:◦ Selection and Use◦ Cleaning and Maintenance
Program
![Page 3: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/3.jpg)
Employee Exposure: exposure to a concentration of an airborne containment that would occur if the employee were not using respiratory protection
FIT Factor: A quantitative estimate of the fit of a particular respirator to a specific individual
FIT Test: A way to evaluate the fit of a respirator on an individual
Definitions
![Page 4: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/4.jpg)
Hazardous Atmospheres: Atmosphere that contains contaminant (s) in excess of the allowable limit or has less than 19.5% oxygen. Contaminants can be generated from direct handling of chemical containing products or as a by-product from regular operations.
Immediately Dangerous to Life and Health (IDLH): Atmosphere that poses an immediate threat to life, or would impair an individual’s ability to escape. IDHL for chlorine is 10 ppm.
Definitions
![Page 5: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/5.jpg)
Protection Factor: A ratio of the air contaminate concentration outside the respirator to the air contaminate inside the respirator◦ A protection factor of 10 means that the respirator can
reduce air contaminates by a factor of 10 Maximum Use Concentration: The mathematical
product of the permissible exposure limit (PEL) and the assigned protection factor◦ Chlorine has a PEL of 0.5ppm. If you have a respirator
with a protection factor of 10, then the maximum use concentration would be 5ppm (0.5ppm x 10 = 5ppm)
Definitions
![Page 6: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/6.jpg)
Qualitative FIT Test: A pass/fail test that relies on an individuals response to the test
Quantitative FIT Test: A test performed by a computer to numerically measure the amount a respirator leaks
Definitions
![Page 7: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/7.jpg)
User Seal Check: An action performed by the user to ensure a proper seal each time the mask is worn
NIOSH: National Institute for Occupational Safety and Health. They test and issue approvals for respirators
Definitions
![Page 8: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/8.jpg)
Different respirators are used for different work environments and different jobs/tasks
Different respirators have different service lives (typically cartridge life)
Different respirators can protect from different/stronger contaminants
Selection and Use
![Page 9: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/9.jpg)
What do you need protecting from?◦ Physical, chemical, and toxicological
determination of all possible contaminants◦ Odor threshold data◦ NIOSH recommended exposure limit◦ ACGIH threshold limit value◦ OSHA permissible exposure limit◦ IDLH concentrations◦ Eye irritation potential◦ How quickly do these contaminants effect
respirators and cartridges
Criteria for Selecting a Respirator
![Page 10: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/10.jpg)
Monitoring should be done to determine the potential for employee exposure
The data collected during this monitoring should be put into a report and distributed to all employees
The monitoring should take place in normal work conditions
Industrial Hygiene Monitoring
![Page 11: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/11.jpg)
Employees working in the process area must carry at least a “Half mask respirator” at all times that will allow evacuation in hazardous atmosphere conditions
In many cases a respirator is required as a precaution in the event of a process upset (ie Chlorine Leak)
An employee should not attempt to deal with an emergency situation when the atmosphere is unknown
Respirator Use
![Page 12: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/12.jpg)
1. First Break involving certain chemicals◦ The list of chemicals can be found in the PPE
section◦ The respirator must be worn for 5-10 min after the
first break has been performed◦ In the event of a release the respirator is used as
an escape respirator 2. Loading Hydrochloric Acid
◦ Respirators are worn during the connect and disconnect process as a precaution
◦ The respirator should be worn for approximately 5-10 minutes per connection
Half Mask and Full face Cartridge Required If…
![Page 13: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/13.jpg)
All the visitor, temporary employees and contractor are required to carry an escape respirator while on the process.
Brief training regarding the use of escape respirator is proved to all the visitors and contractor before entering the plant.
These respirator is to used for escape purpose only and employees should not attempt to deal with the gas release wearing an escape respirator.
Escape Respirator
![Page 14: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/14.jpg)
One example of an engineering control in use at our facility that helps control atmospheric contamination is Chlorine Sensor AIG110.
A specific example of an operation at our facility that generates air contaminants or hazardous atmospheres is the acid column.
The specific type of respirator we use at our facility is a full face respirator for loading acid and in special circumstances. Half mask respirators are used for general respiratory precautions.
Our Facility
![Page 15: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/15.jpg)
At our facility:
The location of the written respiratory protection program can be found in the Safety and Environmental manual.
The place I will store my respirator when not in use is my personal locker.
Our Facility (cont’d)
![Page 16: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/16.jpg)
Respirator users must receive annual training in basic maintenance, inspection, and cleaning. Additional training includes FIT testing (also annually) and any other manufacturers specifications
Negative pressure respirators should not be used when facial scars interfere with the seal
No respirator can be used when any facial hair is present that could interfere with the seal
Restrictions and Requirements for Respirator Use
![Page 17: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/17.jpg)
Workers cannot be exposed to unvarying concentrations of hazardous substances. Individual exposures may vary throughout the facility, a work shift, or days.
The highest concentration of contaminate should be used to compute the required protection factor
Respirator wearers should be aware of the variability in human response to the warning properties of hazardous substances
A user seal check must be completed every time a cartridge respirator is put on
Restrictions and Requirements for Respirator Use
![Page 18: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/18.jpg)
Annual Requirement Must be performed using an exact copy of
the respirator that the employee will wear (Can be the exact respirator that will be worn)
Can be done using a qualitative or quantitative method
FIT Testing protocols must comply with OSHA requirements
FIT Testing
![Page 19: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/19.jpg)
DO NOT supply oxygen For use in areas containing 19.5% oxygen DO NOT use when concentrations of
contaminants are unknown Leave area if:
◦ Breathing becomes difficult◦ Dizziness or distress occurs◦ Taste or smell contaminant
Follow all instructions carefully Never alter or modify
Air Purifying Respirators
![Page 20: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/20.jpg)
1. Headbands: Check to see they have their elasticity. Look for cracks or tears.
2. Face Piece: Check for dirt, cracks, tears, or holes. Inspect for distortion and make sure rubber is still flexible.
Preparations for Use (5 Points)
![Page 21: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/21.jpg)
3. Inhalation/Exhalation Valves: Check for cracks, tears, dirt, and build up of materials.
4. Cartridge Holders: Check gaskets and look for possible damage to threads.
5. Cartridge/Filters: Make sure they are clean and undamaged. Do NOT clean using compressed air.
Preparations for Use (5 Points)
![Page 22: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/22.jpg)
See that straps lie flat on head
Tighten lower “neck” straps
Tighten the “side” straps
Place both hands on headband pad and push it towards the neck
Donning the Respirator
![Page 23: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/23.jpg)
Tighten “neck” and “side” straps again
Tighten forehead or “front” strap a few notches if necessary
Always perform a seal check by placing a palm over the exhale valve and gently exhale. Then place hands over the cartridges/filters and gently inhale till mask collapses
Donning the Respirator
![Page 24: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/24.jpg)
Replace when taste gases or vapors, eye, nose, or throat irritation
If this does not occur cartridges should be changed every six months, or based on the cartridges expiration date
Replacing Cartridges
![Page 25: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/25.jpg)
Respirators should be regularly cleaned and disinfected. Respirator issued for exclusive one worker should be cleaned after each use by wiping interior and exterior with a damp cloth followed by a sanitizing wipe.
Do NOT overheat the respirator by using water warmer than 110°F
Cleaning, Sanitizing, and Maintenance
![Page 26: Defines standard operating procedures to ensure the protection of all employees from respiratory hazards Includes: ◦ Selection and Use ◦ Cleaning](https://reader036.vdocuments.site/reader036/viewer/2022062517/56649e9e5503460f94b9f381/html5/thumbnails/26.jpg)
When inspection shows some signs of problems, get a new respirator or fix the respirator immediately
Never distort rubber face piece
Cleaning, Sanitizing, and Maintenance