Bill Hatch
Amphibious Systems Division
Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02
Improved Flexible Causeway Connector
![Page 2: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/2.jpg)
OPERATIONS IN ELEVATED SEAS REQUIRE SUITABLE CONNECTORS
![Page 3: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/3.jpg)
1. A flexible connector is required if lengths > 160 ft.
• Driven by loads and operational configurations
2. Adapt existing NL P-8 end connector to prototype assets
• Pipe shear connectors
• Flexor tensile connectors
3. Increase safety and efficiency
• Reduce crew involvement in connections
• Provide better alignment and engagement
• Provide automated flexor locking
• Provide automated flexor extension and retraction
FLEXIBLE CONNECTOR DESIGN BASIS
![Page 4: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/4.jpg)
IMPROVED SHEAR CONNECTOR GEOMETRY
WIDE MOUTH RECEIVER
EXTENDED LENGTH SHEAR CONNECTOR
ALIGNMENT AND ENGAGEMENT
![Page 5: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/5.jpg)
IMPROVED SHEAR CONNECTOR PLAN VIEW
![Page 6: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/6.jpg)
NL FLEXOR AND SEABOSS FLEXOR
![Page 7: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/7.jpg)
IMPROVED FLEXOR FABRICATION
![Page 8: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/8.jpg)
SHEAR AND FLEXOR CONNECTIONS
![Page 9: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/9.jpg)
SHEAR AND FLEXOR CONNECTIONS
![Page 10: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/10.jpg)
Extension Methods
•Air motor
•12/24 volt electric winch
•Pneumatic cylinder
•Hand winch
•Pry bar
Locking Methods
•Trigger Plate
•“Door Latch” guillotine
LOCKING AND EXTENSION METHODS
![Page 11: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/11.jpg)
LOCKING METHODS
TRIGGER PLATE
SIDE LATCH
![Page 12: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/12.jpg)
LOCKING METHODS
TRIGGER PLATE SIDE LATCH
![Page 13: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/13.jpg)
EXTENSION METHODS
![Page 14: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/14.jpg)
EXTENSION METHODS PNEUMATIC
![Page 15: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/15.jpg)
EXTENSION METHODS PNEUMATIC CYLINDER
![Page 16: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/16.jpg)
EXTENSION METHODS
![Page 17: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/17.jpg)
EXTENSION METHODS ELECTRIC WINCH
![Page 18: ` Bill Hatch Amphibious Systems Division Naval Facilities Engineering Service Center, Port Hueneme, CA 93043-4370 1/29/02 Improved Flexible Causeway Connector](https://reader036.vdocuments.site/reader036/viewer/2022062321/56649f1c5503460f94c322fc/html5/thumbnails/18.jpg)
PROTOTYPE CONCEPT EVALUATION
1. Hardware to be delivered to Little Creek NAB
• Modules – AAA and USCG
• Flexor connectors
• Extension and locking mechanisms
2. At-Sea testing in March-April timeframe
3. Incorporate recommended design modifications in procurement of replacement Navy lighterage
• Platform-specific flexors
• Durability / reliability testing recommendations