zenoro premium marine generator model: zajdls0555hese · zenoro premium marine generator 4045tfm85...

4
Zenoro Premium Marine Generator 4045TFM85 Marine Generator Set 55 ekW / 50 HZ 1500 rpm Official distributor Created by GENERATOR RATINGS PRIME (KVA AT POWER FACTOR 0,8) Voltage Phase Amps ekW/KVA 400/230 3 144 55/68,75 380/220 3 152 55/68,75 415/240 3 139 55/68,75 JOHN DEERE ENGINE SPECIFICATION INLINE 4 CYLINDERS, 4 CYCLE-DIESEL Engine type 4045TFM85 Prime Power 61 kWm Emission IMO exempt Firing order 1-3-4-2 Displacement 4,5 L (275 cu. in.) Rated engine speed 1500 Bore 106 mm (4,17 in.) Stroke 127 mm (5,00 in.) Aspiraon Turbocharged Combuson Direct injecon Governor Electronic Cooling system Heat exchanged Refill capacity - Cooling system 14 L (3,7 US GAL) - Lube oil system 15 L (3,96 US GAL) Coolant change interval Up to six years or 6000 hours of ope- raon with John Deere COOL-GARD™ II Premix, COOL-GARD II PG Premix and COOL-GARD II Concentrate. Oil change interval 375 hours with John Deere “Plus-50 Oils” & use of Low Sulphur fuel <1000 ppm. Rotaon (from flywheel end) Counter clockwise Engine crankcase venlaon Closed to eliminate engine room system contaminaon ENGINE ELECTRICAL Baery voltage 24 volt isolated ground Baery charging 50 Amps Baery recommendaon 625 CCA COOLING SYSTEM Seawater pump Gear driven impeller type Max. seawater pump sucon liſt 3,0 m (10 ſt) Seawater pump flow 78 Lpm (21 US GALpm) Sea water temp maximum engine in 32 °C Ambient temperature max. 50 °C FUEL Fuel recommended EN 590 or ASTM D975 Fuel injecon system HPCR Recommended fuel line inside diameter 5 mm* *Max. Fuel Inlet Restricon 20 kPa Total fuel flow 71 L/hr (18,8 US GAL/hr) Maximum fuel height above 2,4 m Transfer pump Fuel pre-filter Yard supply min. 30 Mi- cron, recom. 10 micron OPERATION REQUIREMENTS AIR REQUIREMENTS Engine combuson air 4,2 m3/min Max air intake restricon (dirty) 6,25 kPa Cooling air flow required for generator 15,72 m3/min set at 50 °C Exhaust flow 10,51 m3/min Exhaust temperature max. 482°C Maximum Exhaust backpressure 7,5 kPA FUEL CONSUMPTION Diesel fuel consumpon at % load 100% 16,6 l/hr (4,4 US GAL/hr) 75% 12,3 l/hr (3,3 US GAL/hr) 50% 8,5 l/hr (2,2 US GAL/hr) 25% 4,9 l/hr (1,3 US GAL/hr) All above values at rated speed and power at standard condions per SAE J1995 unless otherwise noted. POWER 55 ekW 400 V 50 HZ EMISSION IMO exempt COLOURS RAL 9010 or custom ENCLOSURE aluminium modular design DIMENSIONS 1754 x 820 x 1046 mm WEIGHT dry weight 1100 kg SOUND REDUCTION equal or > than 20 dba at 1 meter free field conditions VIBRATIONS low Model: ZAJDLS0555HESE

Upload: dinhthuan

Post on 10-Dec-2018

265 views

Category:

Documents


0 download

TRANSCRIPT

Zenoro Premium Marine Generator4045TFM85 Marine Generator Set 55 ekW / 50 HZ 1500 rpm

Official distributorCreated by

GENERATOR RATINGS PRIME (KVA AT POWER FACTOR 0,8) Voltage Phase Amps ekW/KVA400/230 3 144 55/68,75380/220 3 152 55/68,75415/240 3 139 55/68,75

JOHN DEERE ENGINE SPECIFICATION

INLINE 4 CYLINDERS, 4 CYCLE-DIESELEngine type 4045TFM85Prime Power 61 kWmEmission IMO exemptFiring order 1-3-4-2Displacement 4,5 L (275 cu. in.)Rated engine speed 1500Bore 106 mm (4,17 in.)Stroke 127 mm (5,00 in.)Aspiration TurbochargedCombustion DirectinjectionGovernor Electronic Cooling system Heat exchangedRefillcapacity- Cooling system 14 L (3,7 US GAL)- Lubeoilsystem 15L(3,96USGAL)Coolant change interval Up to six years or 6000 hours of ope-

rationwithJohnDeereCOOL-GARD™II Premix, COOL-GARD II PG Premix and COOL-GARD II Concentrate.

Oilchangeinterval 375hourswithJohnDeere “Plus-50 Oils” & use of Low Sulphur fuel <1000 ppm.

Rotation(fromflywheelend) CounterclockwiseEnginecrankcaseventilationClosedtoeliminateengineroomsystem contamination

ENGINE ELECTRICALBatteryvoltage 24voltisolatedgroundBatterycharging 50AmpsBatteryrecommendation 625CCA

COOLING SYSTEMSeawater pump Gear driven impeller typeMax.seawaterpumpsuctionlift 3,0m(10ft)Seawaterpumpflow 78Lpm(21USGALpm)Sea water temp maximum engine in 32 °CAmbienttemperaturemax. 50°C

FUELFuel recommended EN 590 or ASTM D975Fuelinjectionsystem HPCRRecommended fuel line inside diameter 5 mm* *Max.FuelInletRestriction 20kPaTotalfuelflow 71L/hr(18,8USGAL/hr)Maximumfuelheightabove 2,4mTransfer pump Fuelpre-filter Yardsupplymin.30Mi-

cron, recom. 10 micron

OPERATION REQUIREMENTS

AIR REQUIREMENTSEnginecombustionair 4,2m3/minMaxairintakerestriction(dirty) 6,25kPaCoolingairflowrequiredforgenerator 15,72m3/minset at 50 °C Exhaustflow 10,51m3/minExhaust temperature max. 482°C MaximumExhaustbackpressure 7,5kPA

FUEL CONSUMPTIONDieselfuelconsumptionat%load100% 16,6l/hr (4,4USGAL/hr)75% 12,3l/hr (3,3USGAL/hr)50% 8,5l/hr (2,2USGAL/hr)25% 4,9l/hr (1,3USGAL/hr)

Allabovevaluesatratedspeedandpoweratstandard conditionsperSAEJ1995unlessotherwisenoted.

POWER 55 ekW 400 V 50 HZ

EMISSION IMO exempt

COLOURS RAL 9010 or custom

ENCLOSURE aluminium modular design

DIMENSIONS1754 x 820 x 1046 mm

WEIGHT

dry weight 1100 kg

SOUND REDUCTION equal or > than 20 dba at 1 meter

free field conditions

VIBRATIONSlow

Model: ZAJDLS0555HESE

ZENORO STANDARD FEATURES- Engine and alternator marine white painted- Singleserviceside(oilfilter,fuelfilter&airfilter)- Doublewalledfuellines- Steel frame to support engine & alternator - Approvedvibrationisolators- Wetelbowthroughenclosure4inchconnection- Junctionbox&controllerboxinonepiece,

central service connector - Emergencybutton- ABS,BVclassification,otherclassificationsocieties byoption

STANDARD ENGINE SAFETY SYSTEM- Horn for alarm warnings- Engine oil pressure low warning & shutdown- Engine coolant temperature high warning & shutdown- Wetexhaustelbowtemperaturehighwarning&shutdown- Fueloilleakagefromdoublewalledfuellineswarning- Over speed shutdown- Belt guard

STANDARD POSITION OF INTERCONNECTIONS, SEE DRAWING- Fuelconnections,fuelinlet/outlet- Seawaterinletpipehoseconnection- Seawateroutletviawetelbow- Oil drain- Opening for AC-load leads- Openingforbatterycables

STANDARD HIGH QUALITY HEAVY DUTY SOUND ENCLOSURE- Highqualitymodularsoundenclosurewithaluminium extrusionprofiles

- RAL9010standardcolor,2layersPowdercoating, 70%gloss,minimumtotallayerthickness120micron measured according ISO 2808

- Easilybuiltup&dismantle- Heavydutyservicepanels,easyremovable- Non-combustibleinsulationmaterialaccordingIMO

(oil & vapour proof)- Separate generator & engine compartment

ENGINE CONTROLLER PLATFORM FEATURES - Providescompleteengine&generatorprotectionand

control- Multipleparallelinggen-setswithinternalload-sharing

controller

DISPLAY / USER INTERFACE- Graphic 128 × 64 pixels display- English language - Buttonswithmechanicalfeedback

ENGINE CONTROL & PARAMETERSEngineparametersarevisualizedondisplayandorModbusRS232as:- Engine running hours - Engine status - Oil pressure - Coolant temperature- Rpm - Engineloadin%- Batteryvoltage - Fuelconsumption

ENGINE FAULT CODE DESCRIPTIONS AND CODES- Automaticrestartofengineafterstartfailure- Coolingdownfunction,allowingthethenenginetocooldownafterstopcommand

- Remote start & stop

HISTORY LOGS- Eventbasedhistory- Reason, Date and Time + all important values are stored- Batterybacked-upRTC

3 PHASE GENERATOR PROTECTIONS- Circuitbreaker(NONmotorized) - Over/Underfrequency- Over/Under voltage - Current/Voltage asymmetry- Overcurrent/Overload

TRUE RMS VOLTAGE MEASUREMENT- 3-phasegeneratorandbusvoltages

TRUE RMS CURRENT MEASUREMENTS- 3 generator phase currents- CT mounted inside generator

POWER MEASUREMENTS- Active/ReactivePowerandPowerFactorperphase- GensetActiveandReactiveEnergycounter- MainsActiveandReactiveEnergycounter- Apparent power

PARALLELING FUNCTIONS- Automaticsynchronizationandbreakercontrol- ActiveLoadSharing- VAr Sharing

Official distributorCreated by

ZAJD

LS05

55HE

SE

ALTERNATOR SPECIFICATIONManufacturer Leroy SomerType LSAM44.3 S2Electrical output 55 ekW/68,75 KVAPower factor 0,8Voltageregulator AVR438+/-0,5%Typeofregulation AREPTemp Rise 115°CInsulationClass HBearing SinglerollerbearingCoupling FlexiblediscIP 23Space heater* 125 W 230/240VAC *Tobeconnected&switchedbyyard

ALTERNATOR FEATURES- Compact & low weight - Standard12wirere-connectablewinding,3-phasebrushless,

2/3 pitch windings- Highefficiency- Shortcircuitcurrentupto300%ofratedcurrent

for 10 seconds- Permanentlygreasedbearingsupto20.000h

GENERAL- Plasticwrappacking- Manualssuppliedincdromformatwithinstruction, OperatingandMaintenanceManual(inPDFformatonly)

- Factory Quality Report

OPTIONAL - Drippanunderneathoil&fuelfilter(s)- EnginecoolantlevellowwarningbyMurphygauge- Engine oil temperature sensor warning & display- Duplexfueloilfilterswitchable- Dry exhaust - Engine oil drain with hose & hand pump- Seawaterflowsensor- ModbusconverterforRS485protocol- Circuitbreaker(motorized)- OptionalInternet/Ethernetconnectionforremotemonitoring- ElectriccablepenetrationswithRoxtec- Siphonbreak- Outsidemuffler&waterseparator- PTO(powertakeofffront)- OtherClassificationsocietiesasLloyds,GL-DNV,RINA- Manuals in hard copy format - Electrical Zero Soot System

REFERENCE CONDITIONS- Rated speed and power- GrossPowerguaranteedwithin+/-5%atSAEJ1995and

ISO3046- J1995andISO1346conditions:- 25 °C (77 °F)air inlet temperature- 99kPa(29.31in.Hg)barometricpressure- 40 °C (104 °F) fuel inlet temperature- 0,853fuelspecificgravity@15°C(60°F)

Ambientairtemperatureisdefinedtobethetemperatureofambientairclosetooperatingvesselthatisnotinfluencedatanymannerbyoperatingcharacteristicsofthevessel(freefieldtemperature).

Allvaluesfromcurrentavailabledata.Subjecttomanufacturingandmeasurementvariationsandtochangewithoutnotice.ActualperformanceissubjecttoapplicationandoperationconditionsoutsideofZenorocontrol.

RATINGSMarineGenerator:TheMarinegeneratorengineratingis thepoweravailableundernormalvaryingelectricalloadfactorsforanunlimitednumberofhoursperyearincommercial applications.Thisratingincorporatesa10%overloadcapability,and conforms to ISO 8528 prime power. Average load over a24-hourperiodshallnotexceed67%oftheprimerating, ofwhichnomorethan2hoursarebetween100%and110% oftheprimerating.

Themarinegeneratorratingisrestrictedtogenerator applicationsonly.Thecriteriausedtoestablishmarinegeneratorapplicationratingsarethesameusedtoestablishindustrialprimepowergeneratorapplicationratings.

Official distributorCreated by

ZAJD

LS05

55HE

SE

DIMENSIONS

Official distributorCreated by

500

200

Seawater inlet position

fuel supply / return connection position

Service space

1754

104

6

820 147

Air inlet

Service space

Cutout for cable gothroughCutout for cable gothrough

Wet Exhaust 100 mm

110 192

150 150

380 902

ZENORO | De Hammen 1 | 5371 MK Ravenstein | The Netherlands | +31 (0)486 201 600 | [email protected] | www.zenoro.com

Premium Generators for Superyachts

NOTE:Generatorsetstobeinstalledabovewaterline.Ifnotconsultfactory. Thisdrawingisprovidedforreferenceonlyandisnotintendedforinstallationpurpose.Contactuseitheryourlocaldistributorfordetailedinformation.

Editi

on 1

5/03

/201

6 ZA

JDLS05

55HE

SE