Straumann 2

The implant-abutment connection may be of great importance for long-term stability and successful outcome of a restoration.

The combination of Straumann abutments on Straumann implants is designed to achieve the best possible performance of the implant-abutment connection and therefore of the entire restoration.

Page 3: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 3

Implant-Abutment Connection

Importance

Straumann® Connections

Risks of Mix and Match

Page 4: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 4

Genuine vs. compatible components

Genuine components are original components designed and manufactured by a company to fit harmoniously into another original component by the same company.

‘Compatible’ components are designed to fit into another company’s genuine - often patented - component. However to get around the patent, the ‘compatible’ part needs to be made differently than the original design. This can increase the risk of complications.

Genuine Components: Restorative Success

Page 5: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 5

Avoid peak stressesConical screw head

Sealed connectionConical implant-abutment interface

Precise guidance at assemblyRadial contact surfaces

High stabilityDeep implant-abutment engagement

1

2

3

4

Benefits of Using Genuine Components

1

2

3

4

Page 6: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 6

1. Avoid Peak Stresses

1

Page 7: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 7

1. Avoid Peak Stresses

Connection design

Conical screw head is designed to offer the clinician additional benefits:

- High resistance to lateral forces

- Even load distribution

- Distribution of anti-rotational and bendingforces

- Even stress distribution to avoid peak stresses

- Minimizes loosening or breakage of the screw

1

Data on file

Page 8: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 8

2. Sealed Connection

Conical implant-abutment interface offersthe clinician the following benefits:

- Supports mechanical stability of systemto lateral forces

- Helps ensure proper seating of the abutment

- Designed to provide a seal against bacterialcontamination, minimizing the microgap

- Designed to reduce the risk of micromovements

2

Data on file

Page 9: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 9

2. Sealed Connection

Relation to crestal bone maintenance

Microgap measurements

Mechanical stability of system to lateral forces

Strength to withstand chewing forces

Bone must be stimulated in a certain range to be maintained and not overused

Designed to reduce bone resorption

Any implant-abutment gap from unharmonized tolerances or mismatched components may cause bacterial infiltration and accumulation, which may impact treatment success

Data on file

Page 10: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 10

Microgap Measurements

Problem statement

A microgap can cause bacterial contamination and micro-movements

How it was investigated

Cut and polished micrographs

Scanning electron microscopy

Data on file

Page 11: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 11

Microgap Measurements

Representative polished micrograph section(magnification: left 50×; right 2500×)Data on file

Page 12: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 12

Microgap Measurements

Results and conclusion

Microgap is below 1µm (0.6 ± 0.3 µm)

Such as small Microgap is intended to prevent bacterial contamination, which is important for crestal bone maintenance

Data on file

Page 13: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 13

3. Precise Guidance at Assembly

Microgap is below 1µm (0.6 ± 0.3 µm)

Such as small Microgap is intended to prevent bacterial contamination, which is important for crestal bone maintenance No additional X-ray needed to verify if impression post or abutment screw is fully seated

3

X-rays courtesy of Dr. Robert Margeas, DDS, Des Moines, IA

Abutment screw fully seated

Page 14: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 14

4. High Stability

Deep implant-abutment engagement

All parts function together as intended

Excellent fatigue strength

Harmonized dimensional tolerances

High-quality materials compatible with each other (screw, implant, abutment) to avoid contact corrosion

Straumann® guarantees the composition of their materials - Straumann cannot guarantee what materials are used by other manufacturers

4

Data on file

Page 15: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 15

3. Precise Guidance at Assembly

Assembly only possible in its correct orientation

Precise abutment placement

Radial contact surfaces

Tactile feedback when fully assembled

Compensates for low visibility

3

Page 16: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 16

Genuine Components Summary

Genuine components are designed to offer technicians and clinicians the following advantages:

- Provide restorations for an excellent outcome

- All parts function together as intended

- Minimize loosening or breakage of the screw

- Help ensure proper seating of the abutment

- Provide a seal against bacterialcontamination, minimizing the microgap

Competitors can only assume dimensions and tolerances of Straumann components

Straumann® support for hands-on training, educational events, business consulting and more

Page 17: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 17

Implant-Abutment Connection

Importance

Straumann® Connections

Risks of Mix and Match

Page 18: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 18

Straumann Implant-Abutment Connection

Straumann® synOcta® Morse taper connection

Straumann Bone Level CrossFit® connection

Tissue Level Implants Bone Level Implants

Page 19: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 19

Straumann Implant-Abutment ConnectionsDesigned to:

Ensure optimal load distribution to reduce peak stresses

Minimize the infiltration of bacteria and contamination in micro-gaps

Have a design harmony between abutment, screw and implant to provide optimal mechanical performance and long-term stability of a restoration

Ensure simple handling of abutments and screws during the assembly process

Page 20: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 20

Straumann Implant-Abutment Connections

Straumann delivers products built on specialization, reliability and simplicity

Genuine components are backed by our Straumann Guarantee.

With Straumann’s Bone Control Design® and unique CrossFit® Connection, the bone level implant and abutment are designed to seamlessly connect for long-lasting, beautiful esthetics.

Straumann parts have undergone mechanical testing and have been engineered precisely to function in a particular mechanical configuration.

Page 21: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 21

Mouth situation

Strength Tests

Two extremes:

A) Biting once on a hard object

(e.g. stone pit in fruit)- single incident

- very high forces

B) Years of chewing - millions of cycles

- low to moderate forces

Fatigue strength• intricate simulation• up to 2 weeks of testing• reference: competitors

Ultimate strength• simple test• fast

Laboratory situation

Page 22: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 22

Conclusion Fatigue Strength

BL Ø 4.8 mm, RC

BL Ø 3.3 mm, NC

BL Ø 4.1 mm, RC

Market average

Straumann®

Bone Level

shoulder diameter [mm]

fatig

ue

str

en

gth

[N

]

0

50

100

150

200

250

300

350

400

450

500

2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0

Data on file

Page 23: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 23

Combined Benefits of Genuine Components Bone Control Design® - Based on 5 key Biological Principles

Page 24: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 24

Combined Benefits of Genuine Components Confidence with CrossFit® Connection

Prosthetic flexibility and stability through a deep conical connection

Clear-cut insertion through the guidance of 4 grooves

Designed to prevent rotation

Page 25: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 25

CrossFit® ConnectionRespects Straumann® strengths: simplicity

Clear-cut insertion through the guidance of 4 grooves

Page 26: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 26

CrossFit® ConnectionRespects Straumann strengths: stability and precision

15° conical connection

4 protrusions

Page 27: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 27

≤ 30°

15° cone

CrossFit® ConnectionRespects Straumann® strengths: flexibility

Page 28: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 28

Limitations of Competitor Design

Competitor abutments are not designed using Straumann’s precise engineering specifications

The square-shaped connection, shown here, provides surface contact with only the protrusions and can undermine security

The resulting imprecise fit leaves gaps that can lead to compromised performance

Page 29: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 29

Straumann® - The Confident Choice

Lifetime limited warranty for implants

5 year warranty for ceramic abutments*

10 year limited warranty for metal abutments*

Conditions:

For implants placed at or after April 01, 2011

Straumann products must be used exclusively with other Straumann products and not in combination with any other manufacturer product

Other conditions apply

*Guarantee includes screw retained bars and bridges and Straumann CARES copings, crowns and bridges

Page 30: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 30

Implant-Abutment Connection

Importance

Straumann® Connections

Risks of Mix and Match

Page 31: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 31

The Risks of Mixing Straumann® Implants with Non-Straumann Abutments

Non-Straumann abutments cannot satisfy Straumann’s strict design and engineering specifications.

Any compromise in the abutment-implant connection can lead to complications including micro-gap bacterial colonization shown to cause bone loss or even a failed implant.

To protect the integrity of your procedure choose components designed for optimal precision.

Page 32: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 32

Identifying the Cost of Compromise*Potential Failure Costs Due to Use of Non-Straumann® Abutment on Straumann Implant

Avg. Estimated Hours

SURGICAL COSTS

Chairtime for explantation 1.5

Regeneration materials 0.25 – 1.0

Chairtime for re-implantation 1.0

Cost of Implant and healing components

Lost opportunity /revenue due to extension of treatment time and additional patient visits

Loss of patient

RESTORATIVE COSTS

Chairtime for impression, temporization and follow-up 3.0

Cost of abutment

Cost of Impression components and materials

Lost opportunity /revenue due to extension of treatment time and additional patient visits

Loss patient

DENTAL LABORATORY COSTS

Labor 1.0

Materials cost*Assumption: Replacement of single implant

Page 33: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 33

Is it Straumann? How to Tell

Page 34: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 34

Is It Straumann®? How to Tell

Our custom abutments bear distinguishing marks that make it easy to be sure you’re using authentic Straumann components.

For Straumann ZrO2 CADCAM components (top row), look for the black laser line around the screw shaft.

For both ZrO2 and Straumann Ti CADCAM components, look for the distinctive yellow and purple tops.

The more you know, the more confident you can feel.

Yellow Magenta

Page 35: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 35

THE CONFIDENT CHOICETHE CONFIDENT CHOICE

Page 36: Your Partner of Choice Straumann Authenticity Name, Function (Arial 20p) Event, Date (Arial 20p)

Straumann 36

Presentation links

Straumann Prosthetics Overview

TL Restorations (procedures detail)

BL Restorations (procedures detail)

Authenticity

Straumann CARES Overview