yield calibration on 2600/2630 display in a 60 series combine

5
Yield Calibration on 2600/2630 Display in a 60 Series Combine 1.Press Main Menu Button. 2. Press "Original GreenStar Monitor" Button.

Upload: others

Post on 10-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Yield Calibration on 2600/2630 Display in a 60 Series Combine

Yield Calibration on 2600/2630 Display in a 60 Series Combine

1.Press Main Menu Button.

2. Press "Original GreenStar Monitor" Button.

Page 2: Yield Calibration on 2600/2630 Display in a 60 Series Combine

3.Press "Setup" Button.

4.Press "A" Button for Harvest Monitor.

Page 3: Yield Calibration on 2600/2630 Display in a 60 Series Combine

5. Press "D" Button for Yield Calibration.

6. Have grain tank empty and press "C" Button to start yield calibration. After you press "C" Button

for Start you can begin harvesting.

Page 4: Yield Calibration on 2600/2630 Display in a 60 Series Combine

7. As you are combining you will notice the harvested weight in pounds start to accumulate. When

you have harvested the desired amount of crop press "C" to Stop the yield calibration.

8. Press "E" Button then enter in Scale Weight using number pad. The Scale Weight Box will turn

white after "E" Button is pressed.

Page 5: Yield Calibration on 2600/2630 Display in a 60 Series Combine

9. Press "E" Button again to accept the Scale Weight. Your Calibration Factor will change

automatically. The Scale Weight Box will go back to black after the "E" Button is pressed.

10. Press Home Button and Return to harvesting.