web lct alcplus2 idu

Upload: jonathan-yovera-rojas

Post on 10-Oct-2015

759 views

Category:

Documents


78 download

TRANSCRIPT

  • WEB LCTALCplus2 IDUALS series equipment with ALCplus2 IDUmanagement software application

    Release 1.1

    User manual

    MN.00237.E - 003Volume 1/1

  • The information contained in this handbook is subject to change without notice.

    Property of SIAE MICROELETTRONICA. All rights reserved according to the law and according to the inter-national regulations. No part of this document may be reproduced or transmitted in any form or by anymeans, electronic or mechanical, without written permission from SIAE MICROELETTRONICA.

    Unless otherwise specified, reference to a Company, name, data and address produced on the screen dis-played is purely indicative aiming at illustrating the use of the product.

    MS-DOS, MS Windows are trademarks of Microsoft Corporation

    HP, HP OpenView NNM and HPUX are Hewlett Packard Company registered trademarks.

    UNIX is a UNIX System Laboratories registered trademark.

    Oracle is a Oracle Corporation registered trademark.

    Mozilla Firefox is a Mozilla Foundation registered trademark.

    Linux term is a trademark registered by Linus Torvalds, the original author of the Linux operating system.Linux is freely distributed according the GNU General Public License (GPL).

    Other products cited here in are constructor registered trademarks.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 1

    WEB LCT ALCplus2 IDUContents

    WEB LCT APPLICATION............................................................................................................ 9

    WEB LCT ALCPLUS2 IDU APPLICATION.................................................................................. 12

    VERSION........................................................................................................................... 13

    LIMITS.............................................................................................................................. 14

    INSTALLATION ...................................................................................................................... 15

    START-UP .............................................................................................................................. 16

    START-UP FROM BROWSER ................................................................................................. 17To open the WEB LCT page from browser (Ethernet connection) ......................................... 17To open the WEB LCT page from browser (USB connection) ............................................... 18To open the WEB LCT page from browser (serial connection).............................................. 18To open the WEB LCT page from browser (connection via modem)...................................... 19Messages displayed at the start of WEB LCT..................................................................... 20

    START-UP FROM SCT/LMT ................................................................................................... 23

    WEB LCT ALCPLUS2 IDU PAGE ............................................................................................... 25

    INFO/STATUS EQUIPMENT AREA .......................................................................................... 26To verify the version of the WEB LCT application............................................................... 28To verify/modify the timeout used for the update of all the information presentin the WEB LCT page..................................................................................................... 28To execute the login of the user ..................................................................................... 28To execute the logout of the user ................................................................................... 29

    CONTEXTUAL AREA............................................................................................................. 30

    EVENTS LIST AREA............................................................................................................. 33To verify/modify the filters applied to the list of the alarm/status signals.............................. 34Alarm and status signals (more info) ............................................................................... 34

    MAIN MENU ........................................................................................................................... 35

    EQUIPMENT PROPERTIES .................................................................................................... 36To verify the equipment properties ................................................................................. 36To modify the equipment identifier.................................................................................. 37To modify the IP address of the agent SNMP of the equipment............................................ 37To execute the equipment software reset......................................................................... 37To align the reference date/time of the equipment to the current date/time of the PC ............ 37

    PORT CONFIGURATION ....................................................................................................... 38To verify/modify the parameters of the communication ports reserved to thelocal and remote supervision of the equipment ................................................................. 38

    Ethernet port ......................................................................................................... 39LCT PPP port .......................................................................................................... 40Radio 1A port ......................................................................................................... 402Mb/s EOC port ...................................................................................................... 41

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 2

    IP Over OSI port..................................................................................................... 42To execute the equipment software reset......................................................................... 43

    ROUTING TABLE................................................................................................................. 44To verify the Routing Table and the Default Gateway currently used by the selectedequipment (Running Routing Table and Running Default Gateway)...................................... 44To add an element to the Routing Table........................................................................... 45To remove one or more elements from the Routing Table................................................... 45To set/modify the IP Address used as Default Gateway...................................................... 46To delete the IP Address used as Default Gateway ............................................................ 46Routing Table and Default Gateway (more info) ................................................................ 46

    STORED ROUTING TABLE .................................................................................................... 48To verify the static Routing Table and the Default Gateway address present into the backupmemory of the equipment controller (Stored Routing Table and Stored Default Gateway)....... 48

    To add an element into the Stored Routing Table .............................................................. 49To remove one or more elements from the Stored Routing Table ........................................ 50To set/modify the IP Address used as Default Gateway into the Stored Routing Table ............ 50To delete the IP address used as Default Gateway into the Stored Routing Table................... 50

    REMOTE ELEMENT TABLE .................................................................................................... 51To verify the remote equipment list................................................................................. 51To add a station to the list ............................................................................................. 52To rename a station of the list........................................................................................ 52To remove a station of the list ........................................................................................ 53To add an equipment to the list ...................................................................................... 53To remove an equipment from the list ............................................................................. 54To reset the remote equipment list ................................................................................. 54Remote equipment list (more info).................................................................................. 54

    PERFORMANCE MONITORING............................................................................................... 56Measures available for the ALCplus2 IDU equipment.......................................................... 57Quality parameters description (PM measures) ................................................................. 58To verify the status of the PM measures .......................................................................... 61To activate a PM measure .............................................................................................. 62To activate all PM measures in a group contemporaneously ................................................ 62To deactivate a PM measure........................................................................................... 62To deactivate all PM measure in a group contemporaneously .............................................. 63To display the results of a measure and the status of the threshold exceeding alarms ............ 63

    G829 RstB1 STM-1 measure........................................................... 64G829 MstB2M1 STM-1 measure ...................................................... 69G828 Radio measure ........................................................................ 74G828 E1 Line Side measure ..................................................................................... 78G828 E1 Radio Side measure ................................................................................... 82G828 STM-1 - Vc12 measure ......................... 84ACM Radio A measure ............................................................................................. 89RxPwr Radio measure....................................................................... 95TxPwr Radio measure ....................................................................... 98

    PM measures (more info)..............................................................................................101

    REPORTS & LOGGERS MAINTENANCE...................................................................................102To save the equipment configuration, the alarm/status signals and the operationsexecuted by the users to file .........................................................................................102To delete the signals stored into the equipment controller .................................................105To delete the operations list stored into the equipment controller .......................................105

    SNTP & WAKE UP CONFIGURATION......................................................................................106To verify the SNTP functionality .....................................................................................106To set the execution parameters and activate the SNTP functionality ..................................107To disable the SNTP functionality ...................................................................................107To verify the Wake Up functionality status ......................................................................108To set the execution parameters and activate the Wake Up functionality .............................108To disable the Wake Up functionality ..............................................................................109

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 3

    Server NTP functionality (more info) ..............................................................................109Wake Up functionality (more info)..................................................................................110

    SD MEMORY MANAGEMENT.................................................................................................111To verify the status and the configuration of the SD memory.............................................111To execute the automatic equipment restart from SD memory in case of replacementof IDU unit .................................................................................................................113To execute the automatic update of the equipment software from SD memory.....................114To execute the management and maintenance of the SD memory......................................115

    To delete the configuration data and/or the equipment sw from the SD memory ............115To disable the automatic equipment restart from SD memory ......................................116To disable the deletion of the equipment sw present in the standby memory benchafter an automatic sw update from SD memory .........................................................116To force the restore of the configuration data and of the equipment sw fromthe SD memory to the controller..............................................................................116To copy the equipment sw from the SD memory to the controller (Sw Dwl SD) ..............116

    SD memory card (more info).........................................................................................117

    SOFTWARE INFO & MAINTENANCE.......................................................................................119To verify the firmware version of the equipment ..............................................................119To update the firmware of the equipment .......................................................................120To switch the functioning of the memory benches relevant to the main controller .................121To verify the WEB LCT version present into the equipment ................................................121To update the WEB LCT application ................................................................................122To verify the communication stack in use........................................................................122To modify the communication stack in use ......................................................................123To execute the equipment software reset........................................................................123Update of the equipment firmware (more info) ................................................................124

    BACKUP/RESTORE CONFIGURATION ....................................................................................125To save the whole equipment configuration (configuration backup) ....................................125To transfer the equipment configuration previously saved (configuration restore) .................125To retrieve the equipment configuration automatically saved by the program beforethe last operation of configuration restore (configuration revert) ........................................126Backup/restore of the equipment configuration (more info) ...............................................126

    UNIT LIST ........................................................................................................................127To verify the characteristics of the equipment units (real configuration) ..............................127

    ACTIVE MANUAL OPERATION ..............................................................................................129To verify the active manual operations ...........................................................................129To verify/modify the manual operation timeout................................................................130

    ALARM SEVERITY CONFIGURATION .....................................................................................131To verify the severity level and the enabling/forwarding status of the alarms.......................131To enable/disable an alarm ...........................................................................................132To enable/disable the forwarding of the trap of an alarm...................................................132To change the severity level of an alarm.........................................................................133Enabling/forwarding/severity of an alarm (more info) .......................................................133

    VIEW LOGGED USER..........................................................................................................134To verify the users connected to the equipment...............................................................134To force the logout of a user .........................................................................................135

    USER MANAGER ................................................................................................................136To verify the user list ...................................................................................................136To add a user to the list ...............................................................................................137To modify a user into the list.........................................................................................137To delete a user from the list ........................................................................................138To change the password and the timeout of the System user (System Password).................138To change the network password and timeout (Network Password) ....................................138To change the password and timeout of the NMS5UX user (CEM password) .........................139To verify/modify the IP address of remote machines that contain a remote user (differentfrom WEB LCT, SCT/LMT or NMS5UX user) who has the possibility to be connected tothe equipment of remote users......................................................................................139

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 4

    User list (more info).....................................................................................................140

    FEATURES MANAGEMENT ...................................................................................................141To verify the functionalities enabled for the equipment .....................................................141To enable the new functionalities ...................................................................................142

    RMON ..............................................................................................................................143To display the enabling/disabling status of the collection of the statistic countersof the equipment Ethernet ports ....................................................................................143To activate the collection of the statistic counters for an Ethernet port ................................144To deactivate the collection of the statistic counters for an Ethernet port.............................144To display the values of statistical counters of an Ethernet port (RMON)..............................144Implementation of the RMON standard in the equipment managed by WEB LCT ...................146

    EQUIPMENT MENU ............................................................................................................... 148

    MAIN MENU ......................................................................................................................149

    EQUIPMENT......................................................................................................................150Configurator ...............................................................................................................151

    To verify/modify the radio configuration....................................................................151To verify/modify the management of STM-1 stream ...................................................153To verify/modify the management of synchronisation .................................................153To verify/modify the management of nodal configuration ............................................153To verify/modify the equipment identifier in the nodal configuration (AlcPlus2...) ...........154To verify/modify the number of equipment of the nodal configuration (AlcPlus2...) .........154To verify/modify the equipment identifier in the nodal configuration (ALplus).................154To verify/modify the number of equipment of the nodal configuration (ALplus)...............154To verify/modify the protection of the nodal configuration (ALplus)...............................155

    Mod. Cap/Link ID.........................................................................................................156To verify the reference band/modulation, the operating status andthe configuration parameters of the adaptive modulation ............................................156To display the table summarizing the radio transport ..................................................158To modify the reference band/modulation .................................................................159To modify the operating status of the adaptive modulation ..........................................159To modify the power profile of the RF transmitter (ACM enabled) .................................159To modify the lower threshold and the upper threshold of the modulation (ACM enabled) 160To modify the number of E1 streams permanently allocated (high priority streams)........160To modify the number of E1 streams assigned to an ACM profile (low priority streams) ...160To verify/modify the link identification number ..........................................................160To verify/modify the priority of the dynamic E1 stream (Extra TDM Cap.) ......................161Adaptive modulation (more info)..............................................................................162

    General Preset ............................................................................................................164To verify/modify the threshold level of the signal at reception......................................164To verify/modify the enabling of the switch in transmission .........................................164To verify/modify the T and N parameters (Tx Switch Control) ......................................165To reset the Transmitter Switch on Remote... alarm (Tx Switch Control) .......................166To verify/modify the radio branch label.....................................................................166

    SYNCHRONISATION...........................................................................................................167To verify the status of the synchronism sources...............................................................167To enable/disable the use of a synchronism source in input ...............................................169To verify/modify the use priority of a synchronism source in input......................................171To force the use of a synchronism source in input ............................................................171To set a synchronism source in input as preferential.........................................................172To set the E1 tributary used as synchronism source for T2/T3 2.........................................172To set the source type used as synchronism for STM-1/NODAL 2 (T0) ................................172To verify the alarms status of synchronism source in input ................................................173To force the status of the T0 synchronisation...................................................................173To verify the alarms status of T0 synchronism .................................................................173To manage the output of synchronism (T12) on tributary A/B and set the interface(output/input) of tributary A/B ......................................................................................174

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 5

    To re-timing the E1s set for the contemporary transport of traffic and synchronisation..........175Management of synchronisation (more info) ....................................................................176

    Synchronism sources in input ..................................................................................176Internal synchronism T0 .........................................................................................179Synchronism in output T12 .....................................................................................179Re-timing of the E1s set for the contemporary transport of traffic and synchronisation ....180

    BASE BAND ......................................................................................................................182Ethernet Switch...........................................................................................................183

    To verify/modify the aging time of the MAC addresses stored in the specific table...........183To verify/modify the maximum size of the accepted packet .........................................185To verify/modify the Eth Type value in the S_Tag QinQ field ........................................185To verify/modify the emptying algorithm of the packets present in the output queue ......185To verify/assign the output queue to a packet, in input to any Ethernet port,

    according to its Tag 802.1p.....................................................................................185To verify/modify the time interval (Hysteresis) after which the Link Loss Forwardingmodality is activated and deactivated .......................................................................186To verify/modify which queue a packet must be assigned to, in input fromthe Ethernet ports, depending on its PTOS/DSCP field (level 3) ....................................186To verify the existing virtual LANs ............................................................................187To create a virtual Lan............................................................................................189To modify the configuration of a virtual Lan...............................................................189To delete a virtual Lan............................................................................................190

    LAN 1, LAN 2, LAN 3, LAN 4 ..........................................................................................191To verify/modify the enabling status of the external port (Lan1, Lan2, Lan3, Lan4).........192To verify/modify the inversion status of the Tx and Rx lines of the external port(Lan1, Lan2 and Lan3, Lan4 electrical interface) ........................................................194To verify/modify the enabling status of the auto negotiation and, if the auto negotiationis inactive, the operation modality and the transmission speed used by the external port (Lan1, Lan2, Lan3, Lan4)........................................................................................195To verify/modify the enabling status of the flow control of the external port(Lan1, Lan2, Lan3, Lan4)........................................................................................195To verify/modify the enabling status of the automatic learning of the MAC Addressin the specific table (Lan1, Lan2, Lan3, Lan4) ............................................................196To restart the auto negotiation procedure for the external port (Lan1, Lan2, Lan3, Lan4) 196To verify/modify the operating modality of the line synchronism (role)(Lan1, Lan2 and Lan3, Lan4 electrical interface) ........................................................196To verify/modify the activation status of the autonegotiation between the rolesof the line synchronism (Lan1, Lan2 and Lan3, Lan4 electrical interface) .......................196To verify/modify the interface type of the external port (Lan3, Lan 4) ...........................197To verify/modify the default Vid value of the external port (Lan1, Lan2, Lan3, Lan4) ......197To verify/modify the control of Tag Vlan Id on the messages in input fromthe external port (Lan1, Lan2, Lan3, Lan4) ...............................................................199To verify/modify the behaviour of the external port towards the packets in output(Lan1, Lan2, Lan3, Lan4)........................................................................................199To force the value of Vid of the external port to the default value(Lan1, Lan2, Lan3, Lan4)........................................................................................200To enable/disable the ports through which the messages in input from the external port(Lan1, Lan2, Lan3, Lan4)........................................................................................200To verify/modify the priority criterion used to associate the packets in input fromthe external port to the output queue (Lan1, Lan2, Lan3, Lan4)...................................201To verify/modify the value to insert in the field 802.1p of the packets in input fromthe external port which, in output, the Tag is added to (Lan1, Lan2, Lan3, Lan4) ...........202To verify/modify the mapping of the priority (802.1p) inside the Tag VLan(Lan1, Lan2, Lan3, Lan4)........................................................................................202To verify the status of the external port in relation to the Spanning Tree protocol(Lan1, Lan2, Lan3, Lan4)........................................................................................202To enable/disable the Spanning Tree protocol for the external port(Lan1, Lan2, Lan3, Lan4)........................................................................................204To verify/modify the priority of the external port (Lan1, Lan2, Lan3, Lan4) (SPT/ELP) .....204To verify/modify the connection cost of the external port (Lan1, Lan2, Lan3, Lan4)

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 6

    (STP/ELP) .............................................................................................................204To verify the status of the external port in relation to the ethernet line protection(Lan1, Lan2, Lan3, Lan4)........................................................................................204To enable/disable the ethernet line protection for the external port(Lan1, Lan2, Lan3, Lan4)........................................................................................205To verify/modify the enabling status of the Link Loss Forwarding modalityof the external port (Lan1, Lan2, Lan3, Lan4)............................................................206To activate/deactivate the loop on line side of the external port(Lan1, Lan2, Lan3, Lan4)........................................................................................207To verify the current status of the laser (Lan3, Lan4 - optical interface) ........................208To verify the type of laser module (Lan3, Lan4 - optical interface)................................209To verify/modify the enabling status of the laser (Lan3, Lan4 - optical interface) ............209To verify/modify the transmission mode of the laser (Lan3, Lan4 - optical interface).......209

    To enable manually the laser transmission (Lan3, Lan4 - optical interface) ....................210To execute the test laser functioning status (Lan3, Lan4 - optical interface)...................210

    Port A ........................................................................................................................211To verify/modify the enabling status of the internal port .............................................211To verify/modify the enabling status of the automatic learning of the MAC Addressin the specific table for the internal port....................................................................212To verify/modify the default Vid value of the internal port ...........................................212To verify/modify the control of Tag Vlan Id on the messages in input fromthe internal port ....................................................................................................214To verify/modify the behaviour of the internal port towards the packets in output ..........214To force the value of Vid of the internal port to the default value..................................215To enable/disable the ports through which the messages in input from the internal port ..215To verify/modify the priority criterion used to associate the packets in inputfrom the internal port to the output queue ................................................................215To verify/modify the value to insert in the field 802.1p of the packets in input fromthe internal port which, in output, the Tag is added to ................................................216To verify/modify the mapping of the priority (802.1p) inside the Tag VLan (internal port)217To verify the status of the internal port in relation to the Spanning Tree protocol............217To enable/disable the Spanning Tree protocol for the internal port................................218To verify/modify the priority of the internal port (STP)................................................219To verify/modify the connection cost of the internal port (STP) ....................................219

    Spanning Tree.............................................................................................................220To verify/modify the version of the Spanning Tree protocol .........................................220To verify/modify the transmission interval of the BPDU packets ...................................221To verify/modify the Forward Delay interval ..............................................................221To verify/modify the maximum lifetime of the BPDU packets .......................................222To verify the status of the Ethernet ports in relation to the Spanning Tree protocol .........222To verify the MAC Address of a bridge ......................................................................223To verify/modify the priority of a bridge....................................................................224To verify the status of the external ports in relation to the ethernet line protection .........224Spanning Tree Protocol (STP) (more info) .................................................................225Ethernet Line Protection (ELP) (more info) ................................................................225

    TDM Tributaries...........................................................................................................227E1 .......................................................................................................................228STM-1..................................................................................................................231VC-4 ....................................................................................................................240VC-12 ..................................................................................................................245

    Cross Connection.........................................................................................................251To display the connections of the equipment in graphic format.....................................251To display the connections of the equipment in table format ........................................257To execute a Tributary-Radio connection...................................................................258To execute a Tributary-Tributary connection..............................................................258To delete one or more connections...........................................................................259To enable the closing of a channel on itself (Auto-Loop) ..............................................259To disable an Auto-Loop .........................................................................................260

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 7

    To verify/modify the connection label .......................................................................260To execute an E1 NBUS E1 connection (AlPlus/3 Element/Protected)......................261Cross connection matrix (more info).........................................................................261

    RADIO .............................................................................................................................265Radio Branch ..............................................................................................................266

    To verify/modify the RF channel on which it is tuned the transmitter of the equipment....266To verify/modify the modulation status of the RF carrier .............................................268To verify/modify the operation of the transmitter .......................................................268To verify/modify the operation of the RT power supply................................................268To verify/modify the resolution of the received power (Prx) .........................................269To verify/modify the resolution of the transmitted power (Ptx).....................................269To verify/modify the functioning status of the ATPC....................................................269To verify/modify the maximum output power value at the transmitter ..........................271

    To verify/modify the intervention threshold (High/Low) of the ATPC device....................271To display the table resuming the minimum/maximum power in transmission/reception for every ACM profile................................................................................271

    MAINTENANCE ..................................................................................................................273LAN Statistics..............................................................................................................274

    To verify the counters of the packets/bytes in input/output from the Ethernet ports........274To reset the counters results ..................................................................................276

    S/N Meas ...................................................................................................................277To verify the measure of the S/N ratio ......................................................................277

    Fade Margin................................................................................................................278To execute the calculation of the link margin and check/delete the results (Fade Margin) 278Messages displayed during the execution of the Fade Margin .......................................280To verify the values of the power parameters stored into the equipment andused for the calculation of the Fade Margin................................................................280Calculation of the link margin (Fade Margin) (more info) .............................................281

    PRBS .........................................................................................................................282To verify the PRBS measure status...........................................................................282To activate/reset the PRBS measure.........................................................................283To deactivate the PRBS measure..............................................................................283To verify/modify the type of PRBS pattern used for the measure ..................................283To enable/disable the used E1 signal for the measure .................................................284

    Radio Loop .................................................................................................................285To verify the radio loops status................................................................................285To activate a radio loop ..........................................................................................286To deactivate a radio loop.......................................................................................286Radio loop (more info)............................................................................................286

    Radio Switch A ............................................................................................................287To verify the status and the configuration parameters of the radio switches...................287To modify the management of the switching in reception (Rx Forced Switch) .................288To modify the management of the switching in transmission (Tx Forced Switch).............288To modify the preferential branch for the service at transmission (Tx Preferential)..........289To modify the Wait Time parameter .........................................................................289To force the switch on the preferential branch without waiting for the Wait Timeexpiration .............................................................................................................289Radio switch (more info).........................................................................................289

    SWITCH ...........................................................................................................................291STM-1........................................................................................................................292

    To verify the status and the configuration parameters of the STM-1 switch ....................292To modify the management of the STM-1 switch ........................................................293To modify the logic of STM-1 switch .........................................................................294To set the primary STM-1 stream as preferential........................................................294To modify the Wait Time parameter .........................................................................294To force the switch on preferential STM-1 stream without waiting for the Wait Timeexpiration .............................................................................................................294

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 8

    STM-1 switch (more info)........................................................................................295Nodal Bus...................................................................................................................296

    To verify the status and the configuration parameters of the nodal switch .....................296To modify the management of the nodal switch .........................................................297To modify the Wait Time parameter .........................................................................297To force the switch on the preferential NBUS connection without waiting forthe Wait Time expiration.........................................................................................297Nodal switch (more info).........................................................................................298

    USER INPUT .....................................................................................................................299Local User Input ..........................................................................................................300

    To verify the local user input status..........................................................................300To verify/modify the name of a local user input..........................................................301To verify/modify the rest condition of a local user input ..............................................301To enable/disable the alarm and to define the severity level of a local user input............301Enabling the user input alarms (more info)................................................................302

    Remote User Input ......................................................................................................303To verify the remote user input status ......................................................................303To change the name of a remote user input ..............................................................304To enable/disable the alarm and to define the severity level of a remote user input ........304

    USER OUTPUT...................................................................................................................305To verify the user output status.....................................................................................305To verify/modify the name of an user output...................................................................306To verify/modify the functioning mode of the relay contacts of an user output .....................306To verify/modify the signals coupled to the user output ....................................................306To enable the forced activation of the relays contact from operator ....................................307To force the user output activation.................................................................................307To remove the forcing of the user output ........................................................................307

    ALARMS LIST ....................................................................................................................... 308

    OPERATIONS LIST ............................................................................................................... 313

    PARAMETERS LIST ............................................................................................................... 321

    GLOSSARY ........................................................................................................................... 327

    ASSISTANCE SERVICE.......................................................................................................... 330

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 9

    WEB LCT APPLICATION

    The WEB LCT application allows an user connecting to an equipment via his own machine (pc, workstation,etc.) using the operating system* and the Web browser at his disposal.

    WEB LCT is an application resident in the equipment controller. It does not require any additional moduleinstalled on the user PC, except for the SCT/LMT program or the WEB Lct Console program, necessary toWEB LCT for the management of the file transfer between PC and equipment (FTP), of the serial/USB/mo-dem connection (PPP) and of the help on-line of WEB LCT (Help Web Server).

    * For operating systems different from MS Windows, a FTP server, an Help WEB server and a PPP management modulemust be installed on ones PC.

    The WEB LCT application can be started:

    From browser (see Fig.1).

    In this case, by means of the WEB LCT interface, it is possible to manage 2 machines at most:local equipment (equipment which you are connected to) and remote equipment (equipment de-fined as Remote Link in the remote equipment list of the local equipment).

    From SCT/LMT program (see Fig.2).

    In this case, the WEB LCT interface of the equipment selected by the SCT/LMT interface isopened.

    Through the WEB LCT application, it is possible to manage:

    The equipment configuration: radio configuration, capacity, modulation, RF channels, tributar-ies, parameters, etc. (pag.148).

    The properties (identifier, addresses, reference date/time, etc.) and to execute the reset of theequipment software (pag.36).

    The communication ports reserved to the local and remote supervision of the equipment(pag.38).

    The stating Routing Table and the Default Gateway address currently used by the equipment(Running Routing Table and Running Default Gateway) (pag.44).

    The static Routing Table and the Default Gateway address stored in the equipment (Stored Rout-ing Table and Stored Default Gateway) (pag.48).

    The remote equipment list (pag.51).

    The measures of Performance Monitoring (pag.56).

    The saving to file of the equipment configuration, of the status/alarm signals and of the opera-tions executed by the users (pag.102).

    The automatic acquisition of the reference date/time of the equipment from a network elementand the Wake Up trap (pag.106).

    The memory card SD for the backup/restore of the equipment configuration and software(pag.111).

    The equipment firmware, the WEB LCT software present in the equipment and the communica-tion stack used by the equipment (pag.119).

    The back-up/restore of the whole equipment configuration (pag.125).

    The hardware constituting the equipment (pag.127).

    The manual operations and the relevant timeout (pag.129).

    The forward status of the alarms and their severity level (pag.131).

    The users connected to the equipment (pag.134).

    The equipment users list (pag.136).

    The functionalities enabled for the equipment (features key) (pag.141).

    The statistic counters of the Ethernet ports of the equipment (pag.143).

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 10

    In order to access the WEB LCT page, a valid SCT/LMT user (username and password) is necessary. Withvalid user (username and password) we mean an user present in the users list stored in the controller (seepag.140).

    It is possible to open:

    More WEB LCT pages on more machines or on the same machine, using the same user or dif-ferent users.

    Only one WEB LCT page relevant to the same equipment.

    More WEB LCT pages relevant to different equipment.

    For more information about the limits of the application, refer to the specific paragraph (pag.14).

    Fig.1 WEB LCT application (start-up of the WEB LCT page from browser)

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 11

    Fig.2 WEB LCT application (start-up of the WEB LCT page from SCT/LMT)

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 12

    WEB LCT ALCPLUS2 IDU APPLICATION

    The WEB LCT application is called WEB LCT depending on the equipment type to man-age.

    This guide describes the WEB LCT ALCplus2 IDU application present in the equipment of series ALS withALCplus2 IDU.

    In this guide, to make the writing easier, the wording:

    WEB LCT identifies the WEB LCT ALCplus2 IDU application.

    ALCplus2 IDU identifies the equipment of series ALS with ALCplus2 IDU.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 13

    VERSION

    The version of the WEB LCT application present in the equipment controller can be verified opening therelevant WEB LCT page and executing one of the following operations:

    Select the About tab.

    Select the command Main Menu > Software info & Maintenance > Web LCT tab.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 14

    LIMITS

    * If the WEB LCT page is opened from browser (local equipment and remote equipment - see Fig.1). If theWEB LCT page is opened from SCT application, the user can connect only to the local equipment (seeFig.2).

    Maximum number of... Limit

    Equipment into the remote equipment list 100

    Stations into the remote equipment list 30

    Equipment which can be connected contemporarily via a singleWEB LCT page

    2 *

    Users (WEB LCT, SCT/LMT e NMS5UX) contemporarily connectedto an equipment via the WEB LCT page

    2

    Signals into the Events List area 400

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 15

    INSTALLATION

    WEB LCT is an application resident in the equipment controller. It does not require any installation on theuser PC.

    To install or update the WEB LCT application present in an equipment, see pag.122.

    As help to the WEB LCT application for the management of the FTP, PPP and Help Web Server, it is neces-sary to use the SCT/LMT or WEB Lct Console program.

    The instructions for the installation of the SCT/LMT and Web Lct Console programs are reported in the rel-evant manuals.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 16

    START-UP

    WEB LCT can be run:

    From browser (pag.17).

    In this case, by means of the WEB LCT interface, it is possible to manage the local equipment(equipment which you are connected to) and the remote equipment (equipment defined as Re-mote Link in the remote equipment list of the local equipment).

    From the SCT/LMT program (pag.23).

    In this case, the WEB LCT interface of the equipment selected by the SCT/LMT interface isopened.

    For the management of the FTP, PPP and Help Web Server, it is necessary to start even the SCT/LMT orWEB Lct Console (WLC) program.

    The instructions to start the SCT/LMT and Web Lct Console programs are reported in the relevant manuals.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 17

    START-UP FROM BROWSER

    The following procedure requires that:

    The relevant WEB LCT application is present on the equipment which you are connecting to.

    The user, you wish to use to open the WEB LCT page, is valid. With valid user (username andpassword) we mean an user present in the users list stored in the controller.

    Depending on the type of used physical connection PC-equipment, follow the specific procedure:

    To open the WEB LCT page from browser (Ethernet connection) - pag.17.

    To open the WEB LCT page from browser (USB connection) - pag.18.

    To open the WEB LCT page from browser (serial connection) - pag.18.

    To open the WEB LCT page from browser (connection via modem) - pag.19.

    To open the WEB LCT page from browser (Ethernet connection)

    If this type of connection is used, checks or settings are not generally necessary. Only if morenetwork cards are equipped, it will be necessary to select the card you wish to use (Host Adapter) (seeWeb Lct Console user manual).

    When the equipment is connected to the PC via LAN network, the relevant WEB LCT page can be openedalso selecting the equipment from the address book of Web Lct Console (see relevant documentation).

    1. If not already active, run WLC program (see relevant documentation).

    2. Run a browser.

    3. Type in the address box:

    http://

    With IP address we mean the address of the equipment supervision port from which you wish to reachthe equipment itself.

    The WEB LCT login page opens.

    4. Type, into the User box, the name of the SCT/LMT user to use to activate the connection.

    5. Type, into the Password box, the access code coupled with the set user.

    6. Check the Remember Me box if you wish that, on the next opening of the WEB LCT application of theconsidered equipment, the current username and password are automatically displayed. Otherwise un-check the considered box.

    7. Press Login.

    If the typed values are correct, the WEB LCT page of the local equipment and of the remote equipmentis displayed.

    Fig.3 shows an example of WEB LCT ALCplus2 IDU pages.

    The items present in the WEB LCT ALCplus2 IDU page of the local equipment and of the remote equip-ment are the same and are described in Fig.5.

    As regards the messages that can be displayed during the start procedure of WEB LCT go to pag.20.

    After the opening of the WEB LCT page depicted in Fig.3, the Login page of the browser remains avail-able pointing out the characteristics of the connected equipment. In any moment, it is possible to closethe WEB LCT page and re-open it without executing the login but simply selecting the label Click herein the Login window.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 18

    To open the WEB LCT page from browser (USB connection)

    If this type of connection is used, before activating the connection, the USB driver must beinstalled and configured (see Web Lct Console user manual).Then, if you think the USB driver does not operate correctly, execute the controls pointed out in the WebLct Console user manual.

    When the equipment is connected to PC via an USB connection, the connection management is implement-ed by WLC program.

    1. Connect the equipment to ones PC by means of the USB cable.

    2. If not already active, run Web Lct Console program and open the relevant graphical interface (see rel-evant documentation).

    The Web Lct Console window opens.

    3. Press Options.

    The Options window opens.

    4. Select the Connect using direct serial cable option in the PPP area.

    5. Press Ok.

    6. Execute one of the following operations:

    In the Web Lct Console window, press Connect.

    Select , press the right button of the mouse and select Connect in the pop-up menu.

    If the connection operation is successful, the default browser is opened with the WEB LCT login page.

    7. Type, into the User box, the name of the SCT/LMT user to use to activate the connection.

    8. Type, into the Password box, the access code coupled with the set user.

    9. Check the Remember Me box if you wish that, on the next opening of the WEB LCT application of theconsidered equipment, the current username and password are automatically displayed. Otherwise un-check the considered box.

    10.Press Login.

    If the typed values are correct, the WEB LCT page of the local equipment and of the remote equipmentis displayed.

    Fig.3 shows an example of WEB LCT ALCplus2 IDU pages.

    The items present in the WEB LCT ALCplus2 IDU page of the local equipment and of the remote equip-ment are the same and are described in Fig.5.

    As regards the messages that can be displayed during the start procedure of WEB LCT go to pag.20.

    After the opening of the WEB LCT page depicted in Fig.3, the Login page of the browser remains avail-able pointing out the characteristics of the connected equipment. In any moment, it is possible to closethe WEB LCT page and re-open it without executing the login but simply selecting the label Click herein the Login window.

    To open the WEB LCT page from browser (serial connection)

    If this type of connection is used, checks or settings are generally not necessary as, at theinstallation of WLC, the Remote Access (LctDirectPPP) is automatically installed and config-ured.If you think the Remote Access does not operate correctly, verify its configuration as points out in Web LctConsole user manual.

    When the equipment is connected to PC via the serial connection, the connection management is imple-mented by WLC program.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 19

    1. Connect the equipment to ones PC by means of the serial cable.

    2. If not already active, run Web Lct Console program and open the relevant graphical interface (see rel-evant documentation).

    The Web Lct Console window opens.

    3. Press Options.

    The Options window opens.

    4. Select the Connect using direct serial cable option in the PPP area.

    5. Press Ok.

    6. Execute one of the following operations:

    In the Web Lct Console window, press Connect.

    Select , press the right button of the mouse and select Connect in the pop-up menu.

    If the connection operation is successful, the default browser is opened with the WEB LCT login page.

    7. Type, into the User box, the name of the SCT/LMT user to use to activate the connection.

    8. Type, into the Password box, the access code coupled with the set user.

    9. Check the Remember Me box if you wish that, on the next opening of the WEB LCT application of theconsidered equipment, the current username and password are automatically displayed. Otherwise un-check the considered box.

    10.Press Login.

    If the typed values are correct, the WEB LCT page of the local equipment and of the remote equipmentis displayed.

    Fig.3 shows an example of WEB LCT ALCplus2 IDU pages.

    The items present in the WEB LCT ALCplus2 IDU page of the local equipment and of the remote equip-ment are the same and are described in Fig.5.

    As regards the messages that can be displayed during the start procedure of WEB LCT go to pag.20.

    After the opening of the WEB LCT page depicted in Fig.3, the Login page of the browser remains avail-able pointing out the characteristics of the connected equipment. In any moment, it is possible to closethe WEB LCT page and re-open it without executing the login but simply selecting the label Click herein the Login window.

    To open the WEB LCT page from browser (connection via modem)

    If this type of connection is used, before activating the connection, the default modem must be config-ured (see Web Lct Console user manual).

    When the equipment is connected to PC via modem, the connection management is implemented by WLCprogram.

    1. Connect the equipment to ones PC by means of the modem.

    2. If not already active, run Web Lct Console program and open the relevant graphical interface (see rel-evant documentation).

    The Web Lct Console window opens.

    3. Press Options.

    The Options window opens.

    4. Select the Connect using a modem option in the PPP area.

    5. Press Ok.

    6. Execute one of the following operations:

    In the Web Lct Console window, press Connect.

    Select , press the right button of the mouse and select Connect in the pop-up menu.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 20

    If the connection operation is successful, the default browser is opened with the WEB LCT login page.

    7. Type, into the User box, the name of the SCT/LMT user to use to activate the connection.

    8. Type, into the Password box, the access code coupled with the set user.

    9. Check the Remember Me box if you wish that, on the next opening of the WEB LCT application of theconsidered equipment, the current username and password are automatically displayed. Otherwise un-check the considered box.

    10.Press Login.

    If the typed values are correct, the WEB LCT page of the local equipment and of the remote equipmentis displayed.

    Fig.3 shows an example of WEB LCT ALCplus2 IDU pages.

    The items present in the WEB LCT ALCplus2 IDU page of the local equipment and of the remote equip-ment are the same and are described in Fig.5.

    As regards the messages that can be displayed during the start procedure of WEB LCT go to pag.20.

    After the opening of the WEB LCT page depicted in Fig.3, the Login page of the browser remains avail-able pointing out the characteristics of the connected equipment. In any moment, it is possible to closethe WEB LCT page and re-open it without executing the login but simply selecting the label Click herein the Login window.

    Messages displayed at the start of WEB LCT

    At the start of WEB LCT, the display of the message:

    Welcome in the WebLct Software upload utility.... The WEB LCT program is not present on theequipment you wish to connect to.

    In order to install WEB LCT, follow the procedure To update the WEB LCT application (pag.122)starting from step 3.

    Warning: in order to view the contents you must install Adobe Flash Player.... It is necessary toinstall or to update the version of Adobe Flash Player present on ones PC for a correct use ofWEB LCT. The program can be installed/updated from the web site:

    www.siaemic.com > Login (to access to the Download area the registration is necessary)> Download area - Software > WEB LCT (Windows version) > Adobe Flash Player...

    www.adobe.com.

    Login Fail. Problem: Invalid User!. It means that the typed username is wrong and/or notpresent in the equipment user list or that the user password is wrong.

    Login Fail. Problem: The equipment is update protected by element manager, retry to login asRead Only user. It means that the equipment is managed also by the NMS5UX/NMS5UX-B/NMS5LX supervisory system and the NMS5UX user has prevented the possibility, for the SCT/LMT user, to be able to execute the login of the equipment.

    In this case, it is necessary that the NMS5UX user enables again the SCT/LMT user for the ex-ecution of the operation.

    Login Fail. Problem: To many WEB users!. It means that the equipment has been connected tothe maximum number of allowed users (see par. Limits - pag.14).

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 21

    Fig.3 WEB LCT page (local and remote equipment)

    Fig.3 notes

    (1) The local equipment is the equipment which you are connected to (equipment which the IP addresstyped in the command line of the browser corresponds to).

    At the opening of the WEB LCT page, the user will be connected to the local equipment with theuser/profile entered during the login request. In any moment it is possible to execute the logout(pag.29) and re-execute the login (pag.28) using the same or a different user with respect to thatused for the login.

    If the equipment is managed also by the NMS5UX/NMS5UX-B/NMS5LX supervisory system, the su-pervisory system considers the connection of a SCT/LMT user with Read Only profile a LCT connec-tion in Monitoring mode. While the supervisory system considers the connection to the equipmentof a SCT/LMT user with Station Operator or System profile a LCT connection in Configuration mode.

    (2) For a correct display of the equipment in the WEB LCT page, it is NECESSARY insert in the remoteequipment table of the local equipment:

    The local equipment with type Managed by SCT.

    The remote equipment with type Remote Link.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 22

    If an equipment of type Remote Link is not present in the remote equipment table, the messageWarning: Unable to open remote element interface... is displayed in this area, pointing out the ab-sence of the remote equipment. Select the label Click here to display, in the WEB LCT page of thelocal equipment, the Remote Element Manager contextual area (see Fig.15) where the remoteequipment table can be managed.

    At the opening of the WEB LCT page, the user will be connected to the remote equipment in Monitormodality. In order to set or modify the parameters of the remote equipment, the user shall executethe login for the remote equipment. Even for the remote equipment, in any moment it is possibleto execute the logout and re-execute the login using the same or a different user with respect tothat used for the first login.

    If more equipment configured as Remote Link are present in the remote equipment list, the ap-plication will automatically acknowledge as remote equipment the FIRST equipment of Remote Linktype present in the list, even if this one is not physically connected, with respect to the local equip-ment, to the other side of the radio link.

    In the remote equipment table, the equipment are sorted in increasing order by their IP address.

    Moreover, the bar Remote Element List is displayed on the right side of the WEB LCT page of thelocal equipment: selecting the bar, the Available Remote Element List pop-up window is displayed,where the equipment configured as Remote Link present in the remote equipment list is listed.

    For each equipment, the following characteristics are reported:

    Station. Station name.

    Equipment ID. Equipment identifier.

    IP Address. IP address.

    Radio Direction. Radio direction (radio branch)

    Radio Link Status. Radio link status between local and remote equipment. Wording:

    Link Up (green). The radio link is active.

    Link Down (red). The radio link is inactive.

    Conn. Status. Connection status between equipment and WEB LCT page (PC). Wording:

    Connected (green). The connection is active.

    Unreacheable (red). The connection is inactive.

    Selecting an equipment in the list, the relevant WEB LCT page is displayed. For example, if the fol-lowing remote equipment list is defined for the local equipment A:

    Equipment B - 172.18.10.23 - Remote LinkEquipment C - 172.18.10.25 - Remote Link

    At the opening of the WEB LCT page of equipment A from browser, the WEB LCT pages of equipmentA and equipment B (equipment of type Remote Link present in the Remote Element Table with low-est IP address) will be displayed. In order to display the WEB LCT page of equipment C, instead ofthat of equipment B, it is sufficient to open the Available Remote Element List window and selectthe area pointing out the characteristics of equipment C.

    To close the Available Remote Element List pop-up window, select the bar Remote Element List.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 23

    START-UP FROM SCT/LMT

    The following procedure requires that:

    The relevant WEB LCT application is present on the equipment you are connecting to.

    The user, you wish to use to open the WEB LCT page, is valid. With valid user (username andpassword) we mean an user present in the users list stored in the controller.

    The SCT/LMT is installed on the PC. More information about the SCT/LMT program is reportedin the relevant documentation.

    1. If not already active, run SCT/LMT program (see relevant documentation).

    2. Activate the connection with the wished equipment (see relevant documentation).

    3. Double click on the record representing the equipment in the SCT/LMT window or selecting the recordof the equipment and the Equipment > LCT Interface command.

    The WEB LCT page of the equipment opens.

    Fig.4 shows an example of WEB LCT ALCplus2 IDU page.

    The items present in the WEB LCT ALCplus2 IDU page are described in Fig.5.

    At the opening of the WEB LCT page, the user will be connected to the equipment with the user/profileof the equipment in the SCT/LMT window.

    In any moment, it is possible to execute the logout (pag.29) and re-execute the login (pag.28) usingthe same or a different user with respect to that used for the login.

    If both the LCT module and the WEB LCT module are available for a given equipment type, the se-lection of the equipment in the SCT/LMT window and the successive selection of the LCT Interfacecommand automatically open the LCT equipment interface.

    Some equipment types have only the WEB LCT program and not the LCT module. In this case, whenthe LCT Interface command is selected, a message is displayed warning that, for the consideredequipment type, only the WEB interface is available. The message is displayed even if the selectedequipment type has the LCT module but this has not been installed on ones PC.

    In this case, there is no need to differentiate the opening of the WEB LCT page according to the con-nection type, as the connection management is executed by the SCT/LMT program itself. For more infor-mation, refer to the relevant documentation.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 24

    Fig.4 WEB LCT page (local equipment)

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 25

    WEB LCT ALCPLUS2 IDU PAGE

    Fig.5 shows an example of WEB LCT ALCplus2 IDU page subdivided in the following areas:

    Info/status equipment area (pag.26)

    Contextual area (pag.30)

    Events List area (pag.33)

    Fig.5 WEB LCT ALCplus2 IDU page

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 26

    INFO/STATUS EQUIPMENT AREA

    The info/equipment status area points out the characteristics and the connection status of the equipmentas depicted in Fig.6.

    The information displayed in the area are updated at regular intervals depending on the timeout set bythe user.

    Moreover, by means of the items present in the area, it is possible:

    To verify the version of the WEB LCT application (pag.28).

    To verify/modify the timeout used for the update of all the information present in the WEB LCTpage (pag.28).

    To execute the login of the user (pag.28).

    To execute the logout of the user (pag.29).

    Fig.6 info/status equipment area (WEB LCT page)

    Fig.6 notes

    (1) The wording ALCplus2 IDU points out the ALCplus2 IDU radio equipment.

    (2) The field is not present if no identifier is assigned to the equipment.

    (3) Label:

    Read & Write, Station Op or System. The equipment is in connected/login status and the userwho has required the login has, respectively, a profile of type Read and Write, Station Op-erator or System.

    Monitor. The equipment is in connected/monitor status or in connected/login status the userwho has required the login has profile of type Read Only.

    (4) Tab:

    About. Displays the version of the WEB LCT application present on the equipment.

    Options. Displays and manages the timeout used for the update of all the informationpresent in the WEB LCT page.

    Login. Manages the login and the logout of the user.

    (5) Label:

    On Line (green). The equipment is in connected status. In this condition, the parameters canbe verified/modified.

    Off Line (red). The equipment is in disconnected status. In this condition, the parameterscannot be verified/modified. The browser sends the command of reconnection at regular in-tervals (timeout set by the user) until when the equipment returns in connected status orthe WEB LCT page is closed.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 27

    (6) Box:

    Urg. Status of the urgent alarms (alarms with Critical or Major severity). The box, accordingto the severity of the alarms present into the equipment, can get different colours:

    Orange. The most serious alarm present into the equipment has Major severity

    Red. The most serious alarm present into the equipment has Critical severity.

    Grey. The equipment has no active alarms with Critical or Major severity.

    Not Urg. Status of the not urgent alarms (alarms with Minor or Warning severity). The box,according to the severity of the alarms present into the equipment, can get different colours:

    Light blue. The most serious alarm present into the equipment has Warning severity.

    Yellow. The most serious alarm present into the equipment has Minor severity.

    Grey. The equipment has no active alarms with Minor or Warning severity.

    Radio 1A. Status of the radio connection with branch 1A.Depending on the equipment configuration type, the box can take on different colours. Indetail in configuration:

    1+0. Color box:

    Green. The radio connection works properly.

    Red. There is loss of radio connection on branch 1A.

    1+1. Color box:

    Green. The radio connection works properly.

    Orange. There is loss of radio connection on branch 1A (the branch 2A workscorrectly).

    Red. There is loss of radio connection on branch 1A (the branch 2A does notcorrectly work).

    Radio 2A. Status of the radio connection with branch 2A.The parameter is meaningful only for equipment in protected configuration.If the box is of color:

    Green. The radio connection works properly.

    Orange. There is loss of radio connection on branch 2A (the branch 1A works correct-ly).

    Red. There is loss of radio connection on branch 2A (the branch 2A does not correctlywork).

    ManOp. Activation status of the manual operations. If the box is of color:

    Light blue. A manual forcing is enabled (e.g. a loop).

    Grey. No manual forcing is active.

    Dwl. Activation status of the update of the equipment firmware. If the box is of color:

    Light blue. The firmware update is in progress.

    Grey. The firmware update is not in progress.

    x C. Operating temperature of the equipment. If the box is of color:

    Green. The operating temperature of the equipment is lower than 75C.

    Orange. The operating temperature of the equipment is between 75C and 80C.

    Red. The operating temperature of the equipment is higher than 80C.

    . Wording:

    1+0. Unprotected radio configuration.

    1+1 FD. Radio configuration with hetero-frequential protection.

    1+1 HS. Radio configuration with iso-frequential protection.

    The absence of alarms, of manual forcing and of download in progress is pointed out by the greybox.

    (7) For each branch, a line is foreseen pointing out from left to right in the column:

    Radio. Branch which the data present in the relevant row refer to. Wording:

    Tx.... Operating status and radio parameters of the branches (1 and 2) relevant totransmission.

    Rx... Operating status and radio parameters of the branches (1 and 2) relevant toreception.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 28

    The boxes Tx2A and Rx2A are present and meaningful only for the equipment in protectedconfiguration.

    The operating status of the branch, independently if the switch is automatic or manual, isrepresented by the colour of the box:

    Green. Working branch.

    White. Standby branch.

    In the equipment in 1+1 hetero-frequential configuration, the branches 1 and 2 transmit atthe same time; in this case both the Tx1A and Tx2A boxes will be green.

    ACM Prof. Current ACM profile.

    TDM Cap. Radio capacity reserved to the TDM tributaries (E1, STM-1).

    ETH Cap. Radio capacity reserved to the Ethernet tributaries.

    Chan - Freq. RF channel expressed as channel number (Chan) and relevant frequency(Freq).

    The wording UNAVAIL. points out that the RF channel is not set.

    Power. Power in input to the receiver (lines Rx) and in output to the transmitter (lines Tx).

    In the equipment in 1+1 isofrequential configuration, the wording Std-by is present in theline Tx relevant to the standby branch.

    Both the powers are measured at the antenna flange.

    To verify the version of the WEB LCT application

    1. Select the About tab (see Fig.6).

    The About tab opens.

    The Version parameter points out the version of the WEB LCT ALCplus2 IDU application present in theequipment controller.

    To verify/modify the timeout used for the update of all the information present in the WEB LCT page

    1. Select the Options tab (see Fig.6).

    The Change Options tab opens.

    The Event polling interval parameter points out the time interval (timeout) between two successive up-dates of the information present in the WEB LCT page.

    2. To modify the parameter, set a number between 5 and 30 seconds.

    3. Press Ok.

    To execute the login of the user

    1. Select the Login tab (see Fig.6).

    The Change Login tab opens.

    2. Type the name of the user, with which you wish to execute the login, in the User box.

    3. Type the access code associated to the set use into the Password box.

    4. Press Login.

    If the operation is successful, the profile of the user who has executed the operation is pointed out inthe Curr. Profile box (Read and Write, Station Operator or System).

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 29

    If the system displays the following message:

    Login Fail. Problem: Invalid User!, it means that the typed username is wrong and/or notpresent in the users list of the local equipment or that the user password is wrong.

    Login Fail. The equipment is update protected by element manager, retry to login as Read Onlyuser, it means that the equipment is managed also by the NMS5UX/NMS5UX-B/NMS5LX super-visory system and the NMS5UX user has prevented the possibility, for the SCT/LMT user, to beable to execute the login of the equipment. In this case, it is necessary that the NMS5UX userenables again the SCT/LMT user for the execution of the operation.

    Problem: To many WEB users! it means that the equipment has been connected to the maxi-mum number of allowed users (see par. Limits - pag.14).

    To execute the logout of the user

    1. Select the Login tab (see Fig.6).

    The Change Login tab opens.

    2. Press Logout.

    If the operation is successful, the wording Monitor is displayed in the Curr. Profile box.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 30

    CONTEXTUAL AREA

    The contextual area is the part of the WEB LCT page where the equipment parameters are displayed. Itscontent changes accordingly to the selected command.

    In WEB LCT the commands allowing to verify/modify the equipment parameters are collected in the fol-lowing menus:

    Main Menu (pag.35). Commands for the management of the general equipment parametersas, for example, the configuration of the supervision ports, the Routing Table, the remote equip-ment table, the measure of Performance Monitoring, etc.

    The commands of the Main Menu are displayed in the contextual area at the opening of theWEB LCT page or each time you select the command Go to Main or Equipment Menu > MainMenu as depicted in Fig.7.

    Equipment Menu (pag.148). Commands for the management of the configuration parameterstypical of the equipment type which the WEB LCT page refers to.

    The command of the Equipment Menu are displayed in a pop-up area that opens when themouse pointer passes over the Equipment Menu as depicted in Fig.8.

    When a command is selected in the Main Menu or in the Equipment Menu, the contextual area displaysall the parameters relevant to the selected command.

    Fig.9 displays an example.

    For some commands, the parameters are subdivided in tabs. If all the tabs are not displayed at the sametime, the arrows keys are displayed to scroll the tabs.

    In detail, use the keys to scroll the tabs and the key to display the list of the tabs.

    The contextual area can moreover display the following messages:

    WARNING. Access enabled only for SYSTEM users. The selected command is available only tothe user with profile System.

    You are forcing a manual operation. Operation timeout: . The setting you wish to exe-cute is a manual operation subjected to timeout.

    For each equipment, a timeout can be set after which the relevant active manual operationsare automatically deactivated (see pag.129). The wording No Timeout points out that the time-out is disabled; this means that a manual operation remains active until when the user deacti-vates it.

    Requesting Data. Please wait!, Sending Data. Please wait!. The request or the sending of datais respectively in progress between the PC and the equipment.

    Operation Fail! Wrong value assigned! A not allowed value has been set.

    Operation Fail! Unable to Get or Update parameter(s). Wrong user profile or not logged yet! Theoperation cannot be executed because the user profile in use is not enabled to execute the actionor is not logged to the equipment yet.

    Not Implemented Yet!. The command is not available for the current version of the program.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 31

    Fig.7 Main Menu commands (WEB LCT page)

    Fig.8 Equipment Menu commands (WEB LCT page)

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 32

    Fig.9 Contextual area (WEB LCT page)

    Fig.9 notes

    (1) Select the Help command to display the help on-line.

    (2) Select the Go to Main command to display in the contextual area the commands of the Main Menu(pag.35).

    (3) Press Refresh to force the reading of the data from equipment.

    If the push-button is not available, the connection with the equipment is not active.

    (4) Press Apply to make the set changes operative.

    Generally, on the selection of the push-button, a confirmation window is displayed. Some confirma-tion windows are timed (for example, the confirmation windows of the manual operations). Whenthis period (pointed out by the clock) is elapsed, if the operator has not confirmed the operation,the window is closed and the operation cancelled.

    If the Apply push-button is not available:

    It is not possible to execute changes because the user profile does not allow this or theequipment is in connected/monitor status.

    No parameter present in the window has been modified. In this case, the push-button be-comes available when the value of a parameter is changed.

    Another push-button is present in the contextual area for the confirmation of the operationor the change of the parameters.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 33

    EVENTS LIST AREA

    The Events List area displays the list of the status and alarm signals stored in the equipment controller asdepicted in Fig.10.

    By means of the items present in the area, it is possible:

    To verify/modify the filters applied to the list of alarm/status signals (pag.34).

    While, by means of the Main Menu > Reports & Loggers Maintenance command, it is possible:

    To save the equipment configuration, the alarm/status signals and the operations executed bythe users to file (pag.102).

    To delete the signals stored into the equipment controller (pag.105).

    For more information about the status/alarm signals, refer to pag.34.

    Fig.10 Events list area (WEB LCT page)

    Fig.10 notes

    (1) To each signal a record is associated, where the following information is reported:

    . Box:

    Green. Status signal.

    Light blue. Alarm detected with Warning severity.

    Yellow. Alarm detected with Minor severity.

    Orange. Alarm detected with Major severity.

    Red. Alarm detected with Critical severity.

    Grey. Alarm detected/cleared.

    Alphanumeric string which details the nature of the signal.

    When the mouse passes over a signal, a window is displayed where the following information is re-ported:

    Signal type:

    Status. Status signal.

    Warning. Alarm detected with Warning severity.

    Minor. Alarm detected with Minor severity.

    Major. Alarm detected with Major severity.

    Critical. Alarm detected with Critical severity.

    Cleared. Alarm detected/cleared.

    Logic group which the signal belongs to: LIM, RT, COMMON, etc.

    Date/time of the signal detection (field In:).

    Date/time of the signal clearing (field Out:).

    This field is present only for the detected/cleared alarms (signals of type Cleared).

    The date/time is set by the network element that has generated the signal. The format of the date/time is the following: month/day/year hour:minutes:seconds.

  • WEB LCT ALCplus2 IDU - MN.00237.E - 003 34

    (2) Wording:

    Filter is Off. No filter is active.

    Filter is On. At least one filter is active.

    (3) The information present in the list are updated at regular intervals.

    The period between an update and the successive one is pointed out by the clock.

    If you want to update the information immediately without waiting for the refresh period select theReload command.

    To verify/modify the filters applied to the list of the alarm/status signals

    1. In the Events list area of the WEB LCT page (see Fig.10) if present the wording:

    Filter is Off. No filter is active for the status/alarm signals displayed in the area.

    Filter is On. At least one filter is active for the status/alarm signals.

    2. To verify the status of the filters, select the Filter is... command.

    A tab opens where the following filters are displayed:

    Status. Status signal.

    Warning. Alarm detected with Warning severity.

    Minor. Alarm detected with Minor severity.

    Major. Alarm detected with Major severity.

    Critical. Alarm detected with Critical severity.

    Cleared. Alarm detected and cleared.

    Box:

    . Filter active. For example, if the Status box is active the status signals will not be present inthe list.

    . Filter inactive.

    3. To modify the filters, activate/deactivate the specific boxes.

    4. Select .

    Each time a filter is applied, not only the currently displayed records are considered, but even all therecords stored in the equipment controller.

    The setting of the filters remains valid until it is not modified by the user or the WEB LCT is closed.

    Alarm and status signals (more info)

    The term alarm defines the fault signal generated by an error or malfunction of the equipment or of anycomponent that composes it.

    The term status identifies instead the signals referring to any event that does not points out a malfunctio