Waterco Ps Heaters

Download Waterco Ps Heaters

Post on 13-Nov-2014

25 views

Category:

Documents

4 download

Embed Size (px)

TRANSCRIPT

<p>Part Number 278562 278812 278852 2788532 27810532 27812532 27815032</p> <p>Product Description Electroheat Digital 55 Mk II Electroheat Digital 80 Mk II Electroheat Plus 85 Mk II Electroheat Plus 85 Mk II (3 Phase) Electroheat Plus 105 Mk II (3 Phase) Electroheat Plus 125 Mk II (3 Phase) Electroheat Plus 150 Mk II (3 Phase)</p> <p>Nominal Size 16kW 23kW 25kW 25kW 31kW 36.5kW 44kW</p> <p>Sizing chart to heat your pool to 28 C Temperate Location* 12hrs / Day Runtime Pool Size (m) 3x7 3.5 x 7 4 x 8.5 5 x 10 5.5 x 11 6 x 12 6 x 15 Litres Up to 35000 Up to 38000 Up to 57000 Up to 76000 Up to 95000 Up to 114000 Up to 133000 with Pool Cover 55 55 80 105 125 150 see dealer 14hrs / Day Runtime Warm Location* 12hrs / Day Runtime 14hrs / Day Runtime</p> <p>No Pool with Pool No Pool with Pool No Pool with Pool No Pool Cover Cover Cover Cover Cover Cover Cover 80 55 55 55 55 55 80 105 55 80 55 80 55 55 125 55 125 55 105 55 85 see dealer 85 150 80 150 55 125 see dealer 105 see dealer 85 see dealer 80 150 see dealer 125 see dealer 105 see dealer 85 150 see dealer 150 see dealer 150 see dealer 125 see dealer</p> <p>Please note : Heat pump sizing is influenced by ambient temperature , humidity , presence of a pool cover , nightly temperatures , pool location , wind factor water features and hours of operation . * Temperate location: Where minimum average daytime temperatures between September to May are not less than 18C. * Warm location: Where minimum average daytime temperatures between September to May are not less than 26C .</p> <p>Technical Specifications Specifications Nominal Heating Capacity btu * Power Output (kW) Supply Voltage (VAC) Supply Voltage Phase Power Consumption (kW/h) Unit Running Amperage (AMP) Fan Full Load Amp (FLA) Breaker or Fuse (AMP) Min./Max. Ambient Air Temperature (C) Min./Max. Water inlet (C) Water Connections (mm) Min./Max. Water Flow Rate LPM Weight (kg) Dimensions A x B x C (mm) Electroheat Electroheat Electroheat Plus Electroheat 55 MKII 80 MKII 85 MKII Plus 105 MKII 55,000 16 240 80,000 23 240 240 Single phase 6.5 29.4 1 40 12 - 40 14/40 40 170 - 200 84 750 x 850 x 1000 25 12 - 40 14/40 40 170 - 200 85,000 25 415 Three Phases 6.5 11.1 105,000 31 415 Three Phases 7.2 11.4 1 25 12 - 40 14/40 40 170 - 200 87 Electroheat Plus 125 MKII 120,000 36.5 415 Three Phases 7.1 10 1 25 12 - 40 14/40 40 170 - 200 89 890 x 880 x 1130 Electroheat 150 MKII 150,000 44 415 Three Phases 7.9 16.4 1 25 12 - 40 14/40 40 170 - 200 93</p> <p>Single phase Single phase 4.2 17.4 1 30 12 - 40 14/40 40 170 - 200 59 735 x 560 x 815 6.8 29.4 1 40 12 - 40 14/40 40 170 - 200 78 915 x 610 x 865</p> <p>Model Electroheat MK II 55 Electroheat MK II 80 Electroheat Plus MK II 85 Electroheat Plus MK II 105 Electroheat Plus MK II 125 Electroheat Plus MK II 150</p> <p>A 735 mm 915 mm 750 mm 890 mm 890 mm 890 mm</p> <p>B 560 mm 610 mm 850 mm 880 mm 880 mm 880 mm</p> <p>C 815 mm 865 mm 1000 mm 1130 mm 1130 mm 1130 mm</p> <p>Part Number 278551 278751 278753 2781003</p> <p>Product Description Electroheat SubZero 55 Electroheat SubZero 75 Electroheat SubZero 75 (three phase) Electroheat SubZero 100 (three phase)</p> <p>Nominal Size 16 Kw 22 Kw 22 Kw 31 Kw</p> <p>Sizing chart to heat your pool to 28 C Model Regional average daytime temperatures Between September to April Over 20C 18C to 23C 10C to 15C 55 55 75 55 75 100 75 75 100 75 100 100 100 100 See Dealer 100 See Dealer See Dealer 100 See Dealer See Dealer</p> <p>Pool Size m 3x7 4x7 4x8 4x9 5x9 5x10 5x11</p> <p>Surface Area m2 21 28 32 36 45 50 55</p> <p>Litres Up to 29400 Up to 39200 Up to 44800 Up to 50400 Up to 63000 Up to 70000 Up to 75000</p> <p>Please note: Heat pump sizing is influenced by ambient temperature, humidity, presence of a pool cover, nightly temperatures, pool location, wind factor, water features and hours of operation.</p> <p>Technical Specifications Models Nominal Heating Capacity btu * Power Output (Kw) Supply Voltage (VAC) Supply Voltage Phase Power consumption (kW/h) Unit Running Amperage Fan Full Load Amp (FLA) Min / Max Breaker or Fuse (AMP) Min./Max. Air Inlet Temperature (C) Water Bypass Type Min./Max. Water Flow Rate (LPM) Min./Max. Water Inlet Temperature (Degrees C) Plumbing Connection Size (Inch. / mm ) ElectroHeat Subzero 55 55,000 BTU 16 240 1 phase 4 16.9 1.0 30 - 40 0 - 40 Ext. Field Install 180 - 225 12 - 40 1 - 1/2 / 40mm 40 - 50 0 - 40 Ext. Field Install 180 - 225 12 - 40 1 - 1/2 / 40mm 240 1 phase 5.4 22.4 1.0 25 0 - 40 Ext. Field Install 170 - 200 12 - 40 1 - 1/2 / 40mm ElectroHeat Subzero 75 75,000 BTU 22 415 3 Phases 5.3 10.1/ Phase ElectroHeat Subzero 100 100,000 BTU 31 415 3 Phases 7.2 10.4 /Phase 1.0 25 0 - 40 Ext. Field Install 180 - 225 12 - 40 1 - 1/2 / 40mm</p> <p>Water Flow &amp; Plumbing Characteristics</p> <p>SubZero 55 A B C 750mm 890mm 870mm</p> <p>SubZero 75 890mm 940mm 990mm</p> <p>SubZero 100 890mm 940mm 990mm</p> <p>SubZero 55 90kg</p> <p>SubZero 75 108kg</p> <p>SubZero 100 118kg</p> <p>Part Number 27125N 27175N 27250N 27325N 27400N 67R0336000</p> <p>Product Description LLC 125 LLC 175 LLC 250 LLC 325 LLC 400 Temperature Rise Measurement Kit All heaters are available for Natural Gas or LPG - Propane N - Natural, V - Outdoor , P - Propane, D - Indoor Note: Prices do not include delivery charges</p> <p>Nominal Size 132MJ/hr 185MJ/hr 264MJ/hr 343MJ/hr 423MJ/hr</p> <p>Part Number 27125J 27175J 27250J 27325J 27400J 274001</p> <p>Product Description LJ125 LJ175 LJ250 LJ325 LJ400 Indoor Vent Cap All heaters are available for Natural Gas or LPG - Propane N - Natural, V - Outdoor , P - Propane, D - Indoor</p> <p>Nominal Size 132MJ/hr 185MJ/hr 264MJ/hr 343MJ/hr 423MJ/hr</p> <p>Temp. Rise above Ambient 8c 11c 14c 17c 20c</p> <p>LLC 125 62sqm 50sqm 37sqm 31sqm 27sqm</p> <p>LLC 175 90sqm 65sqm 55sqm 45sqm 35sqm</p> <p>LLC 250 125sqm 95sqm 75sqm 65sqm 55sqm</p> <p>LLC 325 160sqm 120sqm 100sqm 80sqm 70sqm</p> <p>LLC 400 200sqm 150sqm 120sqm 100sqm 85sqm</p> <p>Spa Size 750 litres 1500 litres 2250 litres 3000 litres 3750 litres</p> <p>LLC 125 30 60 90 120 150</p> <p>LLC 175 21 43 64 86 107</p> <p>LLC 250 15 30 45 60 75</p> <p>LLC 325 12 23 35 46 58</p> <p>LLC 400 9 19 28 37 47</p> <p>Model No.</p> <p>Gas Consumed</p> <p>Heat Output</p> <p>125 175 250 325 400</p> <p>Nom. MJ/hour Nom. Natural LPG Natural 131 118 29 184 166 41 263 236 59 341 307 76 420 377 94</p> <p>LPG Only Qty. LPG 45kg Continuous Time to Water flow through cylinders use one LPG cyl. heater lpm kW - min.* - hours Min. Max. LPG 26.5 2 17 76 475 37 2 12 76 475 53 3 8.2 95 475 68.5 4 6.4 114 475 84.5 4 5.3 114 475</p> <p>Model No. 125 175 250 325 400</p> <p>Vent (V) mm 125 150 175 200 225</p> <p>Width (W) mm 381 457 572 679 806</p> <p>Stack Dimensions Outdoor Indoor A B A 197 359 197 234 371 235 289 476 289 346 457 346 410 527 410</p> <p>B 454 632 635 635 660</p> <p>Shipping Weight kg 81 90 101 116 130</p> <p>B</p> <p>A 114</p> <p>V W 419 254</p> <p>B</p> <p>857 920 89 333</p> <p>203 724</p> <p>Part Number 85540 85530</p> <p>Product Description Flocheck Valve Flocheck Valve</p> <p>Nominal Size 40mm 50mm</p> <p>Part Number 28006 28118 28124</p> <p>Product Description Waterco Single Phase Heater Waterco 3 Phase Heater Waterco 3 Phase Heater</p> <p>Nominal Size 6kW 18kW 24kW</p> <p>18kW &amp; 24kW Three phase Body : 316 grade Stainless Steel</p> <p>6kW Single phase Body : Engineering Plastic</p> <p>Thermostat temperature adjustment Over-temperature sensor Maximum temperature Pressure switch settings Maximum working pressure Maximum pressure International protection rating Amps - 6kW Amps per phase - 18kW Amps per phase - 24kW</p> <p>: : : : : : : : : : :</p> <p>20 deg C - 40 deg C 45 deg C 70 deg C On 35 kPa (3.5m head) Off 15 kPa (1.5m head) 250 kPa 350 kPa IP23 25 amps 25 amps 34 amps</p> <p>Single Phase (6kW)220mm</p> <p>Three Phase (18kW &amp; 24kW)385mm</p> <p>COLD</p> <p>HOT</p> <p>260mm wide</p> <p>480mmOVERALL HEIGHT</p> <p>500mm 240mmOVERALL HEIGHT</p> <p>265mm</p> <p>45mm</p> <p>50mm</p>