viraj ppr slides
TRANSCRIPT
Company Profile
VIRAJ ENGGINEERINGA right blend of professionals from Academic & Industry Experts to give right piping solutions.
Experts who understands Polymer Pipes - Properties & Behavior and hence know exactly how to apply it most efficiently at the site.
We undertake Turnkey Projects in Thermo-weld Piping like HDPE, PPRC, PBT, polycarbonate etc.We have HARD CORE experience in Refurbishment & Retrofitting of Industrial piping.
Successfully carried out various industrial retrofitting projects in Cooling Water Lines, Compressed Air Lines, Acid Regeneration Plants Piping, ETP Plants Piping etc by replacing the Conventional Metal Pipes by Polymer Pipes which does not corrode & are low on Maintenance as well costing.
We provide presales services like surveying BOQ as per your site requirements, as well we do undertake Annual Maintenance Contracts too which reduces hassles of training the in-house staff which automatically gets trained over the period of AMC.
Please go through few pictures of our installations in further slides.
VE CAGE LEAKAGE…PlantS & PipinG
Ctc : [email protected] /M: 9987557248
Service Life Chart With Working Pressure & TemperaturesVE CAGE LEAKAGE…PlantS & PipinG
PN10 PN16 PN20 PN10 PN16 PN20
10 16.1 15.8 32.3 10 8.3 13.2 16.525 15.6 15 31.2 25 8 12.8 1650 15.2 24.3 30.4 50 7.7 12.4 15.5
100 14.8 23.7 29.6 10 6.9 11.1 13.910 13.7 22 27.5 25 6.7 10.7 13.325 13.3 21.3 26.7 50 6.5 10.4 12.950 12.9 20.7 25.9 10 5.8 9.3 11.6
100 12.5 19.5 25.1 25 4.9 7.9 9.910 11.6 18.6 23.2 50 4.3 6.8 8.525 11.2 17.9 22.4 10 4 6.4 850 10.9 17.5 21.9 25 3.2 5.1 6.410 9.9 15.8 19.7 1 3.9 6.2 7.725 9.5 15.2 18.9 5 2.6 4.1 5.250 9.2 14.7 18.4 10 2.2 3.5 4.3
Recommended for COLDRecommended for HOTRecommended for Central Heating
Te
mp
era
tur
e
( in
De
g C
elc
ius
)
Se
rv
ice
Lif
e
( in
Yr
s.)
Pipe Grade According to DIN8077/78 or I.S. 15801
Nominal Pressure
95
80
60
50
70
Permissible Working Pressures are given at Safety Factor of 1.5
20
30
40
Pipe Grade According to DIN8077/78 or I.S. 15801
Te
mp
era
tur
e
( in
De
g C
elc
ius
)
Se
rv
ice
Lif
e
( in
Yr
s.) Nominal Pressure
10
VIRAJ ENGGINEERING
Ctc : [email protected] /M: 9987557248
InstallationsBrine Solution Piping in PPR EPC Plant Piping (Trial)
EPC Plant Piping (Installed)
VE CAGE LEAKAGE…PlantS & PipinG
VIRAJ ENGGINEERING
Ctc : [email protected] /M: 9987557248
Projects Completed & Ongoing Cooling Water Lines
IPCA Laboratories, Waluj-ongoing
IPCA LABORATORIES, WALUJ
VE CAGE LEAKAGE…PlantS & PipinG
VIRAJ ENGGINEERING
Ctc : [email protected] /M: 9987557248