Page 1: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

Vacuum Pumps,Manifolds,

Cups, and Accessories

Page 2: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

Product PageFastvac Pumps

Min Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Mid Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,5Max Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,7

Fastbreak Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Manifolds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8,9Highvac Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Dual-Vac Pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . 11J Series Pumps . . . . . . . . . . . . . . . . . . . . . . . . . 12,13VDF Series Pumps. . . . . . . . . . . . . . . . . . . . . . . . . 14CDF Series Pumps. . . . . . . . . . . . . . . . . . . . . . . . . 15DF Series Pumps . . . . . . . . . . . . . . . . . . . . . . . 16,17

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Sensors, Switches . . . . . . . . . . . . . . . . . . . . . 18,19Vacuum Cups. . . . . . . . . . . . . . . . . . . . . . . . . 20,21Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Silencers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Product PageDrawings . . . . . . . . . . . . . . . . . . . . . . . . . . 24 thru 29

Min Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Fastbreak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Mid Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Max Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Manifold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Highvac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Dual-Vac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28VDF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28CDF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29DF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Glossary of Terms . . . . . . . . . . . . . Inside Back CoverSpecial Products . . . . . . . . . . . . . . Inside Back Cover

TABLE OF CONTENTS

NEW FROM VACCON

Manifolds

Highvac pumps

Dual-Vac pumps

Vacuum sensors and switches

Page 3: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

1Vaccon Co. Inc. 800-848-8788

PRODUCT APPLICATION GUIDE

The following chart is a quick reference guide to some of the hundreds of applications of Vaccon products. Please contactour Applications Department for information on a Vaccon product to meet your specific application requirements.

APPLICATION SELECTION CHART

Application J-Series Fastvac VDF CDF DF Manifold HighVac Dual-VacAir Bearing √Air Wiper √ √Automotive √ √ √ √ √ √ √ √Bag/Box Opening √ √ √ √Blowoff √ √Chip Removal √ √Circuit Board Testing √ √Cooling of Electronics √Degassing √ √ √ √ √Dental/Hospital Suction √ √Dust Removal √ √Evacuation of Molds √ √ √ √ √Evaporation Control √ √ √ √ √Fume Removal √ √Labeling Machines √ √ √Loading Hoppers √Mandrel Collection √ √Paper Feeding/Printing √ √ √ √Pick & Place

Corrugated Sheet/Boxes √ √ √Electronic ComponentsFragile Items √ √ √ √Glass √ √ √Metals √ √ √Plastics √ √ √Stone, Brick, Concrete √

Pneumatic Conveyor √ √ √ √ √Powder Transfer √Replace Raw Air Lines √Unload Feeders √Vacuum Chuck √ √ √Vacuum Clamping √ √ √ √ √Vacuum Filling

Filtration of Liquids/Creams √ √ √Liquids √ √ √Powders √ √ √ √

Vacuum Impregnation √ √ √ √Vacuum Molding √ √ √ √Vacuum Packaging √ √ √ √Vacuum Toilets √ √ √Veneering √ √ √ √

Page 4: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

2Vaccon Co. Inc. 800-848-8788

MIN SERIES VACUUM PUMPS - 60HThe Min Series vacuum pumps offers one high vacuum venturi in several compact, lightweight configurations ideal for smallpart pick and place applications. Other common applications include fast evacuation of small vessels for purging operationsand water/air analyzers. These compact pumps require little installation space and can be positioned close to the vacuumpoint for fast response.

SPECIFICATIONS3 WAY MINI VALVEVALVE TYPE ..............................3/2 Normally Closed Solenoid Operated

Spring ReturnVALVE BODY MATERIAL ..........Anodized AluminumSEAL MATERIAL ......................BunaMEDlA ........................................Filtered (50 Micron), Non Lubricated AirOPERATING PRESSURE ..........0-150 PSIOPERATING TEMPERATURE ..15°-140°FAVERAGE LIFE ..........................100,000,000 CyclesPOWER CONSUMPTION ..........AC: 110 VAC, 50/60 Hz, 2 Watts (w/LED),DC: 24 VDC, 2 Watt (w/LED)RESPONSE TIME ......................8ms Open,15 ms CloseCYCLE RATE..............................2500 Cycles per MinuteELECTRICAL CONNECTION ....DIN 40050MANUAL OVERRIDE ................Standard with Pushbutton

VENTURI SPECIFICATIONSMEDIUM......................................Filtered (50 Micron),

unlubricated airOPERATING PRESSURE ........80 PSIOPERATING TEMPERATURE ..15°F-140°FOPERATING NOISE LEVEL ......68 dBAMATERIAL ..................................Anodized Aluminum, Brass, and Buna-N

Vaccon venturi pumps are designed to operate at peak efficiency at 80PSI. Systems requiring operation at 60 PSI should be ordered with thedesignate -60 at the end of the part number, i e. VP01-60H/24VDC-60

*Specify either 24vdc or 110vac when ordering

For detailed drawings, see page 24.

See page 18 for available accessories.

VP01 -60H*VP01 QR-60H*

VP00-60H

FEATURES: Miniature vacuum pump with silencer.

Compact

Lightweight

Powerful-28" Hg vacuum

Miniature vacuum pump with integral 3way solenoid valve and silencer.

Integral valve ensures high cycle rates,no delay due to long plumbing lines

Modular design eliminates plumbingbetween components and speedsinstallation

Minimizes compressed air consumption- vacuum generated as needed

Miniature vacuum pump with dual solenoidvalves and silencer. Provides all the featuresof the VP01-60H plus:

Positive vacuum blow off for accurateparts positioning and high cycle rates

Individual electrical connections for pre-cise control of vacuum creation and theduration of blow-off

PERFORMANCE DATAAir Consump. (SCFM) VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

Model @ 80 PSI0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

0.50 0.38 0.32 0.30 0.27 0.23 0.20 0.13 0.05 0.02 0.00

60H 0.80 EVACUATION TIME (SECONDS) FOR A 1 CU. FT. VOLUME ("Hg)

0.00 15.00 29.80 50.60 74.50 102.80 135.90 183.20 245.90 410.20 790.80

Quick Action Blow-off

Page 5: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

3Vaccon Co. Inc. 800-848-8788

FASTBREAK HIGH SPEED BLOW OFF VACUUM PUMPS FOR PICK AND PLACE APPLICATIONSVaccon's FASTBREAK vacuum pumps with high speed blow-off areideally suited for pick and place applications that require accurate partplacement and rapid part release. In addition to offering extremely fastblow-off capabilities, the compact FASTBREAK pumps incorporate thesame high quality construction features and superior operating perfor-mance for which Fastvac pumps are known. No external plumbing oron-site assembly is required.

FEATURESExtremely fast part releaseAccurate part positioningOne step installationNo assembly or external plumbing requiredAutomatically cleans vacuum lines

See page 18 for available accessories.For detailed drawings, see page 24.

SPECIFICATIONSOperating Pressure range: 20 to 120 psi Optimum 80 psiOperating Temperature range: 32°F to 125°F (0°C to 52°C)Cycle rates: Up to 300/min.Positive Release Pressure: 10 psiResponse Time: InstantaneousOrientation: Any PositionDuration: Based on System Design

TO ORDERVP0X-Available in the 60H Venturi sizeonly. To order use part number VP0X-60HVP1X-, VP2X-, from 60-150 “M” or “H”,Choose any one of the 8 Venturi's listed inthe below charts. i.e. VP1X-90HVP8X-choose 200M or HVP1X-2X Adjustable option: ADJ

Body StyleVP1XVP2XVP8X

Vacuum Level-H: HighM: MediumVacuum Flow Capacity60, 90, 100, 150

Vaccon venturi pumps are designed to operate at peak effi-ciency at 80 PSI. Systems requiring operation at 60 PSIshould be ordered with the designate -60 at end of the partnumber, i.e. VPIX-100M-60

VP1X-60H

VP0X-60H, VP1X, VP2X, VP8X

200 “M” or “H”

PERFORMANCE DATA M SERIES VENTURIS Medium Vacuum ApplicationsThe “M” series for “Medium” vacuum levels of up to 20" Hg for applications involving porous materials (cardboard, wood, fabric, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 20"60M 0.50 0.50 0.40 0.30 0.22 0.15 0.08 0.03 0.0090M 1.40 1.40 1.25 1.20 1.05 0.85 0.65 0.25 0.00100M 1.80 2.10 2.00 1.85 1.75 1.60 1.25 0.80 0.00150M 2.80 3.50 3.20 2.95 2.75 2.50 1.80 0.95 0.00200M 4.80 6.00 5.30 4.90 4.00 3.50 2.50 1.10 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 20"60M 0.00 12.50 25.10 43.90 68.60 99.30 153.70 227.0090M 0.00 3.75 7.20 12.40 19.10 29.90 52.00 104.00100M 0.00 2.65 5.80 9.90 16.20 22.90 36.20 56.60150M 0.00 1.35 3.20 5.20 7.70 11.80 23.40 52.00200M 0.00 0.75 1.90 3.20 5.30 8.70 17.10 42.60

PERFORMANCE DATA H SERIES VENTURIS High Vacuum ApplicationsThe “H” series for “High” vacuum levels of up to 28" Hg for applications involving non-porous materials (steel, plastic, glass, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"60H 0.80 0.50 0.38 0.32 0.30 0.27 0.23 0.20 0.13 0.05 0.02 0.0090H 1.80 1.20 1.00 0.95 0.90 0.85 0.75 0.70 0.52 0.47 0.20 0.00100H 2.80 2.00 1.85 1.75 1.57 1.40 1.25 1.05 0.84 0.70 0.35 0.00150H 4.80 3.20 2.80 2.50 2.30 2.00 1.60 1.40 1.20 0.80 0.50 0.00200H 7.80 5.40 4.70 3.85 3.30 3.00 2.60 2.10 1.60 1.20 0.60 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"60H 0.00 15.00 29.80 50.60 74.50 102.80 135.90 183.20 245.90 410.20 790.8090H 0.00 6.50 12.30 18.90 32.50 47.00 65.40 92.20 130.00 222.20 281.30100H 0.00 2.70 6.50 11.20 17.50 25.80 38.40 55.20 79.20 166.70 251.80150H 0.00 2.30 3.80 6.50 10.20 14.10 21.30 44.90 55.00 81.00 125.00200H 0.00 1.20 2.10 3.40 5.20 7.70 11.50 20.00 35.50 62.60 98.10

Page 6: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

4Vaccon Co. Inc. 800-848-8788

MID SERIES VACUUM PUMPS–60, 90, 100, 150WITH INTERCHANGEABLE NOZZLE DIFFUSERSFor maximum application versatility, the Mid Series utilizes modular components to allow the designer to specify only thosefeatures necessary for their specific application. Flexibility is further increased through the use of Vaccon’s interchangeablecartridge venturies. Anyone of the eight cartridges can be used with any of the three standard body styles.

Select the venturi that best fits your application based on the four performance characteristics: vacuum level, vacuum flow,evacuation speed, and air consumption (see facing page). To simplify selection, venturi performance has been separatedinto two categories, “M” for medium and “H” for high vacuum applications.

ORDERING INFORMATION1. Choose a body style based on features and accessories

2. Venturi size based on vacuum level and flow requirements

3. If required indicate the valve operating voltage.

4. Order using the following designates:

VP20-100H/24VDC*

Body StyleVP10VP20VP61*

Valve Voltage: •24 VDC •110 VACVacuum Level-H: High•Medium (20" Hg.)•H-High (28" Hg.)Venturi Flow Capacity60, 90, 100, 150

*24VDC or 110 AC only available on VP61

Vaccon venturi pumps are designed to operate at peak effi-ciency at 80 PSI. Systems requiring operation at 60 PSIshould be ordered with the designate -60 at the end of thepart number, i.e. VP10-100H-60

For detailed drawings, see page 25.See page 18 for available accessories.

VP10

VP20

VP61

Venturi vacuum pump with silencer

Compact design–locate close to vacuum point

Venturi vacuum pump with silencer

Optional vacuum sensor (adjustable) pro-vides electrical signal

Optional vacuum gauge provides visual moni-toring, helpful when setting vacuum sensorand troubleshooting

Venturi vacuum pump with integral 6 way solenoidvalve and silencer as standard. Provides precise,rapid vacuum generation and decay.

Integral 6 way valve has dual functions with onlyone electrical connection:

1. Energizes venturi rapidly for high cycle rates–noloss due to plumbing lines.

2. A positive vacuum blow-off is created automati-cally when the valve is de-energized. This allowsthe charged air reservoir within the pump to vent-through the vacuum port for rapid part removal.

Blow-off prevents vacuum line clogging

Eliminates plumbing between components forfaster installation

Optional air reservoir (P/N QRV-10) can be addedfor even faster vacuum release.

SPECIFICATIONS3 WAY & 6-WAY SPOOL VALVE3 WAY VALVE TYPE (optional) ..3/2 Pilot Operated Solenoid Valve w/Spring Return6 WAY VALVE TYPE ..................6/2 Pilot Operated Solenoid Valve w/Spring ReturnVALVE BODY MATERIAL ..........Die Cast ZincSPOOL MATERIAL ....................Polished AluminumSEAL MATERIAL ......................PolyethyleneMEDlA ........................................Filtered (50 Micron), Non Lubricated AirOPERATING PRESSURE ..........45-150 PSIOPERATING TEMPERATURE ..15°-140°FAVERAGE LIFE ..........................100,000,000 CyclesPOWER CONSUMPTION ..........AC: 110 VAC, 50/60 Hz, 2 Watts (w/LED),

DC: 24 VDC, 2 Watts (w/LED)RESPONSE TIME ......................11ms Open, 22 ms CloseCYCLE RATE..............................2000 Cycles per MinuteELECTRICAL CONNECTION ....DIN 40050MANUAL OVERRIDE ................Standard with Pushbutton

VENTURI SPECIFICATIONSMEDIUM......................................Compressed air or other gasesOPERATING PRESSURE ........80 PSIOPERATING TEMPERATURE ..15°F-140°FOPERATING NOISE LEVEL ......72 dBAMATERIAL ..................................Anodized Aluminum, Brass, and Buna-N

INTERCHANGEABLECARTRIDGE ASSEMBLY

Interchangeable within MID SeriesPumps

Precise Control of Flow andEvacuation

Minimize Air Consumption

Standardization of One Pump Style

See page 25 for selection chart.

Optional No blow-off pump (VP31) avail-able with integral 3 way solenoidvalve–contact factory

Quick ActionBlow-off

Page 7: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

5Vaccon Co. Inc. 800-848-8788

H SERIES VENTURIS High Vacuum ApplicationsThe “H” series for “High” vacuum levels of up to 28" Hg for applications involving non-porous materials (steel, plastic, glass, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

60H 0.80 0.50 0.38 0.32 0.30 0.27 0.23 0.20 0.13 0.05 0.02 0.0090H 1.80 1.20 1.00 0.95 0.90 0.85 0.75 0.70 0.52 0.47 0.20 0.00100H 2.80 2.00 1.85 1.75 1.57 1.40 1.25 1.05 0.84 0.70 0.35 0.00150H 4.80 3.20 2.80 2.50 2.30 2.00 1.60 1.40 1.20 0.80 0.50 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

60H 0.00 15.00 29.80 50.60 74.50 102.80 135.90 183.20 245.90 410.20 790.8090H 0.00 6.50 12.30 18.90 32.50 47.00 65.40 92.20 130.00 222.20 281.30100H 0.00 2.70 6.50 11.20 17.50 25.80 38.40 55.20 79.20 166.70 251.80150H 0.00 2.30 3.80 6.50 10.20 14.10 21.30 44.90 55.00 81.00 125.00

M SERIES VENTURIS Medium Vacuum ApplicationsThe “M” series for “Medium” vacuum levels of up to 20" Hg for applications involving porous materials (cardboard, wood, fabric, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 20"

60M 0.50 0.50 0.40 0.30 0.22 0.15 0.08 0.03 0.0090M 1.40 1.40 1.25 1.20 1.05 0.85 0.65 0.25 0.00100M 1.80 2.10 2.00 1.85 1.75 1.60 1.25 0.80 0.00150M 2.80 3.50 3.20 2.95 2.75 2.50 1.80 0.95 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 20"

60M 0.00 12.50 25.10 43.90 68.60 99.30 153.70 227.0090M 0.00 3.75 7.20 12.40 19.10 29.90 52.00 104.00100M 0.00 2.65 5.80 9.90 16.20 22.90 36.20 56.60150M 0.00 1.35 3.20 5.20 7.70 11.80 23.40 52.00

PERFORMANCE DATA

Page 8: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

6Vaccon Co. Inc. 800-848-8788

MAX SERIES VACUUM PUMPS - 200, 250, 300, 350

The Max Series offers high vacuum flow rates for rapid evacuation of large volumes of air. The Max Series is ideal for vacuum filling operations or where leakage must be overcome in order to sustain high vacuum levels while handling porousmaterials. The Max series venturis are commonly used in applications where:

ORDERING INFORMATION 1. Body styles and venturi size have been combined for a total

of 8 models.

2. Order using the following part numbers:

VP80-200M VP90-300M

VP80-200H VP90-300H

VP80-250M VP90-350M

VP80-250H VP90-350H

Vaccon venturi vacuum pumps are designed to operate atpeak efficiency at 80 PSI. Systems requiring operation at 60PSI should be ordered with the -60 at the end of the part num-ber i.e., VP90-350H-60.

SPECIFICATIONSVENTURI

MEDIUM....................................Filtered (50 Micron), unlubricated air

OPERATING PRESSURE.........80 PSI

OPERATING TEMP...................15°F-140°F

OPERATING NOISE LEVEL .....72 dBA

MATERlAL .................................Anodized Aluminum

For detailed drawings, see page 26.

See page 18 for available accessories.

One vacuum pump is powering multi-ple vacuum cups.

Large vacuum cups handle heavy,porous objects.

Systems have large vacuum lines orrotary vacuum valves which operate athigh cycle rates (200-300/min).

Evacuating a vessel with a vol-ume of 1/2 cu.ft. or larger.(Normally, smaller volumes canbe handled by the Mid Series.)

VP80-200 (M OR H) VP80-250 (M OR H) VP90-300,350 (M OR H)

The VP80- and VP90- models are available with optional vacuum gauge (VG-150). Mechanical and solid state vacuumsensors and switches can be factory installed upon request.

Page 9: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

7Vaccon Co. Inc. 800-848-8788

H SERIES VENTURIS High Vacuum ApplicationsThe “H” series for “High” vacuum levels of up to 28" Hg for applications involving non-porous materials (steel, plastic, glass, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

200H 7.80 5.40 4.70 3.85 3.30 3.00 2.60 2.10 1.60 1.20 0.60 0.00250H 12.50 9.00 8.50 7.85 7.00 6.50 5.30 3.90 2.50 1.80 0.90 0.00300H 22.00 20.00 17.00 14.00 12.70 12.00 10.00 7.40 4.90 2.70 1.30 0.00350H 28.00 28.00 22.00 18.70 15.90 14.50 11.80 8.10 5.70 4.50 2.25 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

200H 0.00 1.20 2.10 3.40 5.20 7.70 11.50 20.00 33.50 62.60 98.10250H 0.00 0.75 1.30 2.20 3.50 5.60 9.10 17.40 30.10 56.00 76.00300H 0.00 0.00 0.80 1.20 2.00 2.80 3.90 5.90 11.10 32.70 60.00350H 0.00 0.00 0.00 1.20 1.90 2.30 3.40 5.30 8.80 26.00 44.00

M-SERIES VENTURIS Medium Vacuum ApplicationsThe “M” series for “Medium” vacuum levels of up to 20" Hg for applications involving porous materials (cardboard, wood, fabric, etc.) or where leakage is present.

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 20"

200M 4.80 6.00 5.30 4.90 4.00 3.50 2.50 1.10 0.00250M 7.80 9.50 9.20 8.30 7.00 4.70 3.40 2.20 0.00300M 12.50 20.00 19.00 16.30 13.80 8.10 5.50 3.30 0.00350M 17.00 28.00 24.00 19.40 16.80 14.50 11.20 4.80 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 20"

200M 0.00 0.75 1.90 3.20 5.30 8.70 17.10 42.60250M 0.00 0.45 1.10 2.40 3.80 6.00 9.70 15.40300M 0.00 0.00 0.00 1.10 1.80 2.70 4.60 8.70350M 0.00 0.00 0.00 1.00 1.50 2.10 4.30 8.40

PERFORMANCE DATA

Page 10: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

8Vaccon Co. Inc. 800-848-8788

The Vaccon MID SERIES of segmented manifolds offermaximum application versatility where multiple vacuum sta-tions are required. The manifolds utilize modular compo-nents that enable the designer to select from eight inter-changeable cartridges and specify only the features neces-sary for their specific application.

For total operating flexibility, any of the 60M through 150Hcartridges can be used in any of the vacuum stations toobtain the optimum flow and vacuum levels while keepingair consumption to an absolute minimum.

FEATURES

Modular designInterchangeable cartridges and sensorsPrecision blow-off controlRapid recoveryAvailable with up to 20 vacuum stations

For detailed drawings see page 27.

MID SERIES SEGMENTED MANIFOLDS - 60, 90, 100, 150

ORDERING INFORMATION

1. Use specifications chart on page 9 to select venturi(s) based on vacuum level, vacuum flow, evacuation speed, and air consumption.

2. Select vacuum switch/sensor configuration and layout from below

3. Select valve voltage and layout from below

VM5-xxxxx-nnnnn-vvvvv

Vacuum Manifoldw/no. of Stations

Venturi Cartridge*Sizes and LayoutA=60M E=100M B=60H F=100H C=90M G=150M D=90H H=150H

*Each segment must have appropriate size and cartridge designation up to 20 segments.

Valve Voltage and Layout1 =12VDC 2=24VDC

Vacuum Switch/SensorConfiguration and Layout1=VSXP - SOURCING SWITCH2=VSXN - SINKING SWITCH3=VSXL - LOGIC SWlTCH4=VSSA - 4-20mA SENSOR5=VSSV - 0-5VDC SENSOR

Manifold segments numbered left to right

1 2 3 4 5

Page 11: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

9Vaccon Co. Inc. 800-848-8788

H SERIES VENTURIS High Vacuum ApplicationsThe “H” series for “High” vacuum levels of up to 28" Hg for applications involving non-porous materials (steel, plastic, glass, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

60H 0.80 0.50 0.38 0.32 0.30 0.27 0.23 0.20 0.13 0.05 0.02 0.0090H 1.80 1.20 1.00 0.95 0.90 0.85 0.75 0.70 0.52 0.47 0.20 0.00100H 2.80 2.00 1.85 1.75 1.57 1.40 1.25 1.05 0.84 0.70 0.35 0.00150H 4.80 3.20 2.80 2.50 2.30 2.00 1.60 1.40 1.20 0.80 0.50 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

60H 0.00 15.00 29.80 50.60 74.50 102.80 135.90 183.20 245.90 410.20 790.8090H 0.00 6.50 12.30 18.90 32.50 47.00 65.40 92.20 130.00 222.20 281.30100H 0.00 2.70 6.50 11.20 17.50 25.80 38.40 55.20 79.20 166.70 251.80150H 0.00 2.30 3.80 6.50 10.20 14.10 21.30 44.90 55.00 81.00 125.00

M SERIES VENTURIS Medium Vacuum ApplicationsThe “M” series for “Medium” vacuum levels of up to 20" Hg for applications involving porous materials (cardboard, wood, fabric, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 20"

60M 0.50 0.50 0.40 0.30 0.22 0.15 0.08 0.03 0.0090M 1.40 1.40 1.25 1.20 1.05 0.85 0.65 0.25 0.00100M 1.80 2.10 2.00 1.85 1.75 1.60 1.25 0.80 0.00150M 2.80 3.50 3.20 2.95 2.75 2.50 1.80 0.95 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 20"

60M 0.00 12.50 25.10 43.90 68.60 99.30 153.70 227.0090M 0.00 3.75 7.20 12.40 19.10 29.90 52.00 104.00100M 0.00 2.65 5.80 9.90 16.20 22.90 36.20 56.60150M 0.00 1.35 3.20 5.20 7.70 11.80 23.40 52.00

PERFORMANCE DATA

Page 12: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

10Vaccon Co. Inc. 800-848-8788

Vaccon’s Highvac vacuum pumps achieve vacuum levels inexcess of 29.5"Hg and offer a wide range of vacuum flowrates. They are ideal for vessel evacuation, process control,and HVAC applications. Because the assembly has nomoving parts they are easy to clean. The HIGHVAC pumpis ideal for applications where contaminants are present.

Their high vacuum rates, compact size, design featuresallow system designers to use smaller and less costly com-ponents and reduce maintenance repair costs.

FEATURES

Vacuum levels in excess of 29.5"HgCompact sizeNo moving parts

For detailed drawings, see page 27.

See page 18 for available accessories.

HIGHVAC SERIES VACUUM PUMPS

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 4" 8" 12" 16" 20" 24" 28" 29.5"

HVP 100 4.90 1.20 0.97 0.90 0.85 0.73 0.60 0.50 0.20 0.00

HVP 200 8.60 3.20 2.75 2.40 2.10 1.55 1.30 0.80 0.35 0.00

HVP 300 22.00 6.00 5.20 3.50 3.10 2.45 1.50 1.20 0.45 0.00

PERFORMANCE DATA

Vacuum Level: The magnitude of suction created by the vacuum pump. Vacuum level is effected by elevation andbarometric pressure. For each 1000 feet of elevation, vacuum decreases by approximately 1" Hg.

Page 13: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

11Vaccon Co. Inc. 800-848-8788

DUAL-VAC SERIESFOR THE RAPID EVACUATION OF MOLDS,VESSELS, AND CONTAINERS.

Vaccon’s Dual-Vac Series of vacuum pumps are designedto meet industry’s need for an economical rapid evacuationof molds, vessels and containers.

The Dual-Vac Series of pumps achieve both a high rate ofvacuum flow, for exceptional speed of evacuation, and ahigh level of vacuum through the use of two different vacuum devices combined in one compact unit.

FEATURES

High flow ratesHigh vacuum levelsCompact sizeReduced air consumption

SPECIFICATIONSSize . . . . . . . . . . . . . . . . 14"l x 4.5"w x 5"h

Weight . . . . . . . . . . . . . . 8 lbs.

Air Inlet . . . . . . . . . . . . . 1/2" NPTF

Vacuum Inlet . . . . . . . . . Combination 2" dia and 1.5" dia Barbed Fitting

Operating Pressure . . . . 80 psi

For detailed drawings, see page 27.

AIR CONSUMPTION1

MAXIMUM VACUUM VACUUM LEVELS1

(SCFM) FLOW1(SCFM) ("Hg)

MODEL

HIGH FLOW HIGH VAC HIGH FLOW HIGH VAC HIGH FLOW2 HIGH VAC3

Dual-Vac 5/150 24 3 30 3 up to 8 25

Dual-Vac 7/250 48 14 60 15 up to 8 25

Dual-Vac 10/500 48 44 95 60 up to 5 25

PERFORMANCE DATA

1. All levels @ 80 psi supply pressure

2. Field adjustable

3. Factory preset to customer specification (default is 25"Hg)

Page 14: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

12Vaccon Co. Inc. 800-848-8788

J SERIES VACUUM PUMPS

VACCON’s J Series of air powered vacuum pumps areavailable in 16 standard models with a full range of optionalaccessories for pick and place and other similar applica-tions where reliable vacuum and high performance arerequired. J Series pumps operate with instantaneousresponse in pulsed applications or on a continuous basis.

The rugged, cylindrical design of the J series makes it idealfor use in adverse operating conditions. These mainte-nance free pumps have no moving parts or seals thatrequire replacement. The pump’s light weight, compact con-figuration facilitates installation close to the work area givingthe added advantage of increased response time andreducing the need for using a larger pump.

J Series pumps are manufactured from anodized alu-minum. For high temperature and/or caustic applications,stainless steel, PVC, and other materials are available.

A transducer produces a vacuum by forcing compressed airthrough a limiting orifice into a venturi section. As the airexits the orifice it expands, increasing in velocity to super-sonic speeds before entering the venturi section. This cre-ates a vacuum or negative pressure at the vacuum inletport located between the orifice and venturi section. Thishigh velocity insures efficient and effective operation.

ORDERING INFORMATIONSelect a J Series pump with the lowest air consumption thatmeets the application requirements based on the followingcriteria: Vacuum Level, Vacuum Flow, Vacuum Force,and Cycle Times.

See page 30 for detailed selection criteria

Standard operating supply pressure for the J Series is80psi. Specify 60psi supply power if required by adding -60psi after model number.

Specify pump model: i.e. JS-250

Specify accessories and vacuum cup

PRINCIPLES OF OPERATION

The use of Vaccon silencers is strongly recommended.They will reduce noise level up to 30 dB without back pressure.

J Series can also be powered by alternate medias. Consultfactory.

See page 18 for available accessories.

For detailed drawings, see page 28.

FEATURES

Instant responseRugged, cylindrical designMaintenance freeAvailable in wide range of materials

Page 15: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

13Vaccon Co. Inc. 800-848-8788

JS series for “High” vacuum levels of up to 28" Hg for applications involving non-porous materials (steel, plastic, glass, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

JS60M 0.80 0.50 0.38 0.32 0.30 0.27 0.23 0.20 0.13 0.05 0.02 0.00JS90M 1.80 1.20 1.00 0.95 0.90 0.85 0.75 0.70 0.52 0.47 0.20 0.00JS100M 2.80 2.00 1.85 1.75 1.57 1.40 1.25 1.05 0.84 0.70 0.35 0.00JS150M 4.80 3.20 2.80 2.50 2.30 2.00 1.60 1.40 1.20 0.80 0.50 0.00JS200 7.80 5.40 4.70 3.85 3.30 3.00 2.60 2.10 1.60 1.20 0.60 0.00JS250 12.50 9.00 8.50 7.85 7.00 6.50 5.30 3.90 2.50 1.80 0.90 0.00JS300 22.00 20.00 17.00 14.00 12.70 12.00 10.00 7.40 4.90 2.70 1.30 0.00JS350 28.00 28.00 22.00 18.70 15.90 14.50 11.80 8.10 5.70 4.50 2.25 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 21" 24" 27" 28"

JS60M 0.00 15.00 29.80 50.60 74.50 102.80 135.90 183.20 245.90 410.20 790.80JS90M 0.00 6.50 12.30 18.90 32.50 47.00 65.40 92.20 130.00 222.20 281.30JS100M 0.00 2.70 6.50 11.20 17.50 25.80 38.40 55.20 79.20 166.70 251.80JS150M 0.00 2.30 3.80 6.50 10.20 14.10 21.30 44.90 55.00 81.00 125.00JS200 0.00 1.20 2.10 3.40 5.20 7.70 11.50 20.00 33.50 62.60 98.10JS250 0.00 0.75 1.30 2.20 3.50 5.60 9.10 17.40 30.10 56.00 76.00JS300 0.00 0.00 0.80 1.20 2.00 2.80 3.90 5.90 11.10 32.70 60.00JS350 0.00 0.00 0.00 1.20 1.90 2.30 3.40 5.30 8.80 26.00 44.00

JD series for “Medium” vacuum levels of up to 20" Hg for applications involving porous materials (cardboard, wood, fabric, etc.)

ModelAir Consumption VACUUM FLOW (SCFM) VS. VACUUM LEVEL ("Hg) @ 80 PSI

(SCFM)@ 80 PSI 0" 3" 6" 9" 12" 15" 18" 20"

JD60M 0.50 0.50 0.40 0.30 0.22 0.15 0.08 0.03 0.00JD90M 1.40 1.40 1.25 1.20 1.05 0.85 0.65 0.25 0.00JD100M 1.80 2.10 2.00 1.85 1.75 1.60 1.25 0.80 0.00JD150M 2.80 3.50 3.20 2.95 2.75 2.50 1.80 0.95 0.00JD200 4.80 6.00 5.30 4.90 4.00 3.50 2.50 1.10 0.00JD250 7.80 9.50 9.20 8.30 7.00 4.70 3.40 2.20 0.00JD300 12.50 20.00 19.00 16.30 13.80 8.10 5.50 3.30 0.00JD350 17.00 28.00 24.00 19.40 16.80 14.50 11.20 4.80 0.00

ModelEVACUATION TIME (SECONDS) BASED ON 1 CU. FT. VOLUME ("Hg)

0" 3" 6" 9" 12" 15" 18" 20"

JD60M 0.00 12.50 25.10 43.90 68.60 99.30 153.70 227.00JD90M 0.00 3.75 7.20 12.40 19.10 29.90 52.00 104.00JD100M 0.00 2.65 5.80 9.90 16.20 22.90 36.20 56.60JD150M 0.00 1.35 3.20 5.20 7.70 11.80 23.40 52.00JD200 0.00 0.75 1.90 3.20 5.30 8.70 17.10 42.60JD250 0.00 0.45 1.10 2.40 3.80 6.00 9.70 15.40JD300 0.00 0.00 0.00 1.10 1.80 2.70 4.60 8.70JD350 0.00 0.00 0.00 1.00 1.50 2.10 4.30 8.40

PERFORMANCE DATA

Page 16: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

14Vaccon Co. Inc. 800-848-8788

VDF SERIESVARIABLE FLOW VACUUM PUMPS

The VDF Series of adjustable air powered vacuum pumpsprovides a combination of high vacuum flow rates of up to120 SCFM, and vacuum levels of up to 25" Hg. Because ofits straight-through design, the VDF Series is ideal forhandling porous materials and operation in contaminatedsituations.

We have named this unit the “Dirty One” because of itsability to pass virtually all contaminants through its internalstructure. VDF pumps can be used to pick and placeconcrete block, or packaging materials that are coated withfine powder, and are commonly used in industrial air drivenvacuum cleaners to remove liquid/solid mixtures from sumpareas.

VDF pumps are field adjustable and eliminate the need foradditional regulation of air lines to remotely vary the levelsof vacuum or flow that is required.

PRINCIPLES OF OPERATION

The variable performance of the VDF pump is achieved byincreasing the annular gap between the venturi nozzle andthe diffuser. Rotating the diffuser section counter-clockwisewill increase the opening, allowing more compressed air toflow through the unit and increasing both the vacuum flowand the vacuum level. The result is a variable vacuumpump that can be adjusted to meet an application’s exactrequirements.

FEATURES

Ideal for dirty environments

Non-clogging, straight-through design

High performance to air consumption ratio

Field adjustable for your specific application

See page 18 for available accessories.

For detailed drawings, see page 28.

PERFORMANCE DATA

Model Air Consumption vs. Vacuum Level ("Hg) @ 80 PSINumber

0" 5" 10" 15" 20" 25"VDF 100 0 .70 1.20 1.30 2.10 2.60VDF 150 0 1.30 1.70 2.40 3.20 4.50VDF 200 0 2.40 3.70 4.70 6.00 6.80VDF 250 0 4.00 6.00 8.30 9.70 12.00VDF 375 0 6.20 11.50 17.00 21.00 29.00VDF 500 0 12.00 22.00 28.00 33.00 45.00VDF 750 0 23.00 30.80 44.00 63.00 90.00

Model Vacuum Flow vs. Vacuum Level ("Hg) @ 80 PSINumber

0" 5" 10" 15" 20" 25"VDF 100 0 .85 .90 1.20 1.60 2.00VDF 150 0 1.10 1.60 2.10 2.60 3.20VDF 200 0 2.20 3.00 4.00 5.20 6.00VDF 250 0 4.50 5.80 7.20 8.60 10.00VDF 375 0 14.00 18.50 22.00 26.00 30.00VDF 500 0 23.00 35.00 40.00 47.00 60.00VDF 750 0 40.00 51.00 69.80 87.00 120.00

The "Dirty One''

RecommendedSilencerST-4ST-4ST-4

ST-4A2ST-8B

ST-12CST-16C

Max AirVacuum Consumption

Flow SCFM SCFM*2.00 1.303.20 2.406.00 4.70

10.00 8.3030.00 17.0060.00 28.00

120.00 44.00

* These values can be achieved at 15"Hg.

Page 17: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

CDF SERIES VACUUM PUMPSFOR AIR AMPLIFICATION

The CDF Series of air amplifiers generates both a highvacuum flow and a high exhaust flow using only a smallamount of compressed air. The CDF can be used for appli-cations requiring high levels of vacuum flow to rapidly evac-uate large areas. They can also be used where porosity is amajor problem and a standard Vaccon unit does not gener-ate enough flow to offset the loss of vacuum.

The unique design of the CDF pump makes it an efficientand cost effective alternative to electric blowers or largevolumes of raw compressed air.

Seven standard models are available with bores of 1/8" to2". Air velocity and flow of all models are field adjustable toprovide a wide range of conditions to meet individualapplication requirements.

Amplification ratios as high as 40:1 (output to input) can beachieved with the CDF series.

PRINCIPLES OF OPERATION

CDF pumps operate on the “Coanda Effect” where a smallvolume of compressed air is converted into a large flow ofambient air. Compressed air is emitted from an annular gapand passes over a curved surface into the throat of the unit.As the air passes over this curved surface, similar to an airfoil, a low pressure area is created inducing ambient air toflow into the throat with the compressed air.

TYPICAL APPLICATIONS

Blow drying

Fume evacuation

Cooling

Improved utilization of compressed airFor detailed drawings, see Page 29.

PERFORMANCE DATAMODEL I.D. **INPUT OUTPUT VELOCITYNO. INCHES SCFM SCFM FT/SEC

CDF 100* 1/8 3 12 23472 8 15651 6 1173

CDF 200* 1/4 3 18 8602 14 6851 10 490

CDF 500H† 1/2 9 75 9105 42 5303 22 265

CDF 750H† 3/4 9 110 5655 70 4203 40 195

CDF 1000H† 1 9 145 4355 95 2903 57 174

CDF 1500H 1 1/2 9 240 3145 150 1983 86 123

CDF 2000H 2 9 350 2695 220 1683 140 106

Jam nut used to secure adjustment* 1/4" NPT male exhaust available

** Data is at 80 PSI† See page 29 for optional threaded exhaust attachments

FEATURES

High, 40:1 amplification ratios

Field adjustable

Instant response

Cost effective

15Vaccon Co. Inc. 800-848-8788

Page 18: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

16Vaccon Co. Inc. 800-848-8788

DF SERIESHIGH FLOW VACUUM PUMPSFOR MATERIAL TRANSFER

Vaccon’s DF Series of high flow vacuum pumps provides areliable and cost effective method of in-line transfer ofcomplex shapes and bulk materials such as; small parts upto 3 inches in diameter, continuous strips, and powders.

Vacuum flow rates can be infinitely controlled over thepumps entire range by regulating the input pressure.

The pump’s unique capability to create instantaneousvacuum flow and high air velocity combined with its straightthrough, smooth bore design allows material to passdirectly through the unit at high speeds without interferenceor clogging.

Its compact design facilitates placement close to the workarea for maximum efficiency and ease of installation.

DF pumps are available in 15 standard models with insidesdiameters from 1/8" to 3". Modified and custom engineeredunits are also available.

FEATURES

Application versatility

High efficiency

Low initial and operating cost

Maintenance free operation

Custom units available

PRINCIPLES OF OPERATION

Compressed air is fed into an exterior annular ring that hasa number of orifices leading into the main tube of a trans-ducer. As the compressed air exits from the orifices, itsvelocity increases to supersonic speed. The air forced intothe center of the tube rotates with a twisting motion similarto a worm screw. This cyclonic flow creates a powerfulvacuum capable of drawing materials into, and through thetransducer.

As a vacuum source, the DF series are capable of rapidevacuation of a large volume of air to a low vacuum level.

ORDERING INFORMATION

Select a DF pump based on the following:

Inside diameter

Velocity of flow

Vacuum flow

Vacuum force

Air consumption

Contact factory for custom pumps

APPLICATIONS

Unloading vibrator feeders

Reloading hoppers with plastic Regrind

Transferring of engine valves in grindingoperation

Chip removal in drilling operation

Transfer power detergent and caustic chemicals

Convey peanut husks

Selvedge removal in trimming operation

Mandrel collection system

Page 19: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

PERFORMANCE DATA

MODEL I.D. AIR VACUUM VACUUM AIR CONSUMPTIONNO. VELOCITY FLOW LEVEL @ 40 PSI @80 PSI

(ft/sec) (SCFM) (" Hg)

DF 1-3 1/8 585 3 8 1.1 2

DF 2-3 1/4 490 10 8 3.1 6

DF 3-3 3/8 328 15 4.5 3.5 6

DF 3-6 3/8 393 18 6 5.8 10

DF 5-3 1/2 306 25 3 5.2 9

DF 5-6 1/2 362 30 10 14 24

DF 7-3 3/4 272 50 4.3 14 24

DF 7-6 3/4 326 60 8 28 48

DF 10-3 1" 229 75 3 14 24

DF 10-6 1" 290 95 5.8 28 48

DF 15-3 1-1/2 224 165 1.3 14 24

DF 15-6 1-1/2 272 200 2.5 28 48

DF 20-3 2 183 240 0.8 14 24

DF 20-6 2 229 300 1.5 28 48

DF 30-6 3 168 375 .7 32 60

Values for velocity, vacuum flow, and vacuum level are for 80 psi input pressure

DF SERIES

ModelDIMENSIONS

I.D. (NPTF)A B C D E F G H I

DF1-3 1/8 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF2-3 1/4 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF3-3 3/8 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF3-6 3/8 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF5-3 1/2 1 1/2 1 5 1/2 1 1 1/4 3 1/4 5/8 1/4DF5-6 1/2 1 1/2 1 5 1/2 1 1 1/4 3 1/4 5/8 1/4DF7-3 3/4 2 1 1/4 7 1/2 1 1/2 2 4 1 3/8DF7-6 3/4 2 1 1/4 7 1/2 1 1/2 2 4 1 3/8DF10-3 1 2 1/4 1 1/2 7 1/2 1 1/2 2 4 1 3/8DF10-6 1 2 1/4 1 1/2 7 1/2 1 1/2 2 4 1 3/8DF15-3 1 1/2 2 3/4 2 7 1/2 1 1/2 2 4 1 3/8DF15-6 1 1/2 2 3/4 2 7 1/2 1 1/2 2 4 1 3/8DF20-3 2 3 1/4 2 1/2 7 1/2 1 1/2 2 4 1 3/8DF20-6 2 3 1/4 2 1/2 7 1/2 1 1/2 2 4 1 3/8DF30-6 3 4 1/4 3 1/2 10 1/2 2 3 5 1/2 1 1/2 1/2

17Vaccon Co. Inc. 800-848-8788

Page 20: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

18Vaccon Co. Inc. 800-848-8788

ACCESSORIESACCESSORY SELECTION GUIDE

PRODUCT VACUUM FILTER GAUGE SILENCER SILENCER SOLENOID SWITCH SWITCH SENSORCUPS AA ST VALVE MECH'L SOLID SOLID

STATE STATE

MINI SERIES Ã Ã Ã Ã Ã Ã Ã Ã Ã

MID SERIES Ã Ã Ã Ã Ã Ã Ã Ã Ã

MAX SERIES Ã Ã Ã Ã Ã Ã Ã

FASBREAK Ã Ã Ã Ã Ã Ã Ã Ã

HIGH VAC Ã Ã Ã Ã

J SERIES Ã Ã Ã Ã Ã 1 1 1

VDF SERIES Ã Ã Ã

1 Remote applications only

ADJUSTABLE VACUUM SWITCHESThese sensors are ideal for use in automated systems to generate a low current electrical signal for input to a PLC or otherlogic controller. They are normally open, diaphragm operated and utilize low stressing deflecting contacts instead of slidingor pivoting parts, resulting in high reliability and long life.

SX-4, SX-5To reduce plumbing andease installation, thevacuum sensors may befastened directly to theVP20, VP31, and theVP61 series of vacuumpumps.

SX-4SB, SX-5SBFor remote mountingchoose theSX-4SB or SX-5SB subbase mounted versions.

VS4, VS5Adjustable vacuumsensor.

Part No Size Range Hysteresis/ Input Max. Output Operating Port Indi- Electrical(inches) Deadband Voltage Current Temp. cator Connection

MECHANICAL SWITCHESVS-4 1x1x3/8 w/ 2-14.8"Hg. 1/2 % max 500 VAC/ 10-20 mA Sourcing -40°-250°F n/a None 12" flying leads

3/8x3/16Æbarb value 24 VDCVS-5 1x1x3/8 w/ 7.4-30"Hg. 1/2 % max 500 VAC/ 10-20 mA Sourcing -40°-250°F n/a None 12" flying leads

3/8x3/16Æbarb value 24 VDCSX-4 1x1.5x.75 thk 2-14.8"Hg. 1/2 % max 500 VAC/ 10-20 mA Sourcing -40°-250°F Optional Sub None 12" flying leads

value 24 VDC Base w/10-32SX-5 1x1.5x.75 thk 7.4-30"Hg. 1/2 % max 500 VAC/ 10-20 mA Sourcing -40°-250°F Optional Sub None 12" flying leads

value 24 VDC Base w/10-32VSW5A 1.84x4.26 4-28"Hg. ~ 20% 125-250 VAC 5 amp Sourcing -40°-176°F 1/8" NPTM None DIN 43650A

12 VDC 7 amp N/O or N/C24 VDC 5 amp

Model No. VSW5A

VACUUM GAUGE

Model No. VG-150

The VG-150 is a 0-30" Hg.vacuum gauge with a 1-1/2"face and an 1/8" NPTMbottom mount connection.

Nema 6 Enclosure (IP67)

Adjustable, 4" to 28" Hg.

Electrical Connection–DIN 43650A

UL and CSA Approved

Compact, sealed vacuumswitch for automation andprocess control applica-tions. Especially suited forhazardous applicationsincluding wash down anddust laden air.

Switch is field adjustablebetween 4" and 28"Hg.Adjusting screw is easilyaccessed below the DINconnector. Wiring can beeither Normally Open orNormally Closed.

IMPORTANT NOTICE:The electrical circuit is from one terminal, through the rivet to the contact blade; and from the other terminal, through the rivet, to the adjustment blade. Theadjustment screw is in contact with the diaphram and is part of the electrical circuit. To avoid potential shock, please use an insulated screwdriver when making adjustments.

Page 21: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

SOLID STATE SWITCHES AND SENSORS

Note 1: All solid state devices, sold individually, are mounted to a 1/8" thick base with a #10-32 female port. Optional male port adapters are available in10-32 and 1/8" NPT.

Note 2: All solid state devices, sold individually, can be optionally mounted to a 3/8" thick remote mounting base with a #10-32 port. NOTE: 1/8" NPTAdapters are not available with this option.Remote Mount Option Suffix: -RMOptional Port Adapters:

#10-32 Adapter: -321/8" NPTM Adapter: -18

Vaccon’s ultra miniature electronic vacuum and pressuresensing and switching devices utilize the latest electronictechnology available. They provide precision control forfeedback mechanisms or system monitoring and they canbe incorporated directly onto Vaccon’s Fastvac vacuumpumps. These devices are available for manifold applica-tions where multiple sensing points for vacuum or pressureare required.

For applications requiring feedback for batch or processcontrol, the sensors are available as a 0-5Vdc or 4-20mAvolt transducer device. Vacuum or pressure setpoints, andhysteresis are adjustable on all switches.

Part No Size Range Hysteresis/ Input Max. Output Operating Port Indi- Electrical(inches) Deadband Voltage Current Temp. cator Connection

SOLID STATE SWITCHESVSXP 1x.75x.41 thk 0.5-30" Hg. ~ 0-15% 5-30 VDC 100mA Sourcing -40°-150°F See notes 1&2 LED 3 conductor/24"VSXN 1x.75x.41 thk 0.5-30" Hg. ~ 0-15% 5-30 VDC 100mA Sinking -40°-150°F See notes 1&2 LED 3 conductor/24"VSXL 1x.75x.41 thk 0.5-30" Hg. ~ 0-15% 5-30 VDC 100mA Sinking -40°-150°F See notes 1&2 LED 3 conductor/24"

w/pullupresistor

PSXP 1x.75x.41 thk 10-150 psi ~ 0-15% 5-30 VDC 100mA Sourcing -40°-150°F See notes 1&2 LED 3 conductor/24"PSXN 1x.75x.41 thk 10-150 psi ~ 0-15% 5-30 VDC 100mA Sinking -40°-150°F See notes 1&2 LED 3 conductor/24"PSXL 1x.75x.41 thk 10-150 psi ~ 0-15% 5-30 VDC 100mA Sinking -40°-150°F See notes 1&2 LED 3 conductor/24"

w/pullupresistor

SOLID STATE SENSORSVSSA 1x.75x.41 thk 0.5-30" Hg. n/a 18-28 VDC n/a 4-20mA -40°-150°F See notes 1&2 n/a 2 conductor/24"VSSV 1x.75x.41 thk 0.5-30" Hg. n/a 12-30 VDC n/a 0-5 VDC -40°-150°F See notes 1&2 n/a 3 conductor/24"PSSA 1x.75x.41 thk 10-150 psi n/a 18-28 VDC n/a 4-20mA -40°-150°F See notes 1&2 n/a 2 conductor/24"PSSV 1x.75x.41 thk 10-150 psi n/a 12-30 VDC n/a 0-5 VDC -40°-150°F See notes 1&2 n/a 3 conductor/24"

.750

19Vaccon Co. Inc. 800-848-8788

Page 22: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

20Vaccon Co. Inc. 800-848-8788

VACUUM CUPS4 STYLES TO FIT YOUR APPLICATION: BELLOWS, CLEATED, OVAL, STANDARD

Available in 3 materials:

Vinyl ............................................ Durable, resists wear, up to 125°F

Silicon.......................................... High temp., FDA approved, up to 400°F (-76°F)

Polyurethane............................... Chemically resistant up to 125°F

4 BASIC CUP STYLES

STANDARD

Standard cups are flexible and work well in applications that do not requirelifting heavy loads. In food packaging for example, a standard cup can beused to apply a label to an uneven surface such as a package of chicken.

CLEATED

Cleated cups are strong with a rigid, low profile that will lift heavy loads. Thelow profile allows heavy loads to be lifted vertically without the cup “peeling”away from the product surface. These cups perform well when grippingsmooth, flat heavy objects such as steel sheet, glass (television picturetubes), and coated corrugated.

BELLOWS – with 1, 2, 3 or 4 convolutions

Bellows cups have a pliable outer rim that will conform to curved or unevensurfaces while the bellows sections compensate for inconsistent stackheights. Under vacuum, the accordion-style bellows cup will collapse oncontact. The collapsing action simulates a short cylinder stroke lifting theproduct for a short distance, possibly saving the need for a separate liftingmechanism.

OVAL

Like cleated cups, oval cups have heavy load handling capacity due to theirrigid design and large vacuum work area. Oval cups have the largest liftingforce because they provide the most surface area for a given cup footprint.

CUP STYLES

Equation for calculating vacuumlifting force using vacuum cups:Note: To covert ("Hg) vacuum level intoPSI divide by 2.

Vacuum Force (lbs.) x Safety Factor =Vacuum Level (PSI) x Surface Area (in.2)

Suggested Safety Factor:2 for cup in horizontal position. 4 for cup in vertical position

D

E

Page 23: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

Standard Model No. Approx. Area in2 A (O.D.) B C D E StyleVC 1 .01 .200 .225 .045 .225 .057 AVC 165A .05 .37 .25 .25 .37 .22 BVC 25 .02 .61 .62 .10 .50 .19 BVC 10 .30 1.00 .50 .28 .62 1/8 NPTF BVC 11 .40 1.19 .50 .28 .75 1/4 NPTF BVC 12 .60 1.44 .50 .50 .75 1/4 NPTF BVC 8 .44 1.50 .56 .38 .62 .23 BVC 37A .50 1.56 .81 .50 .87 1/4 NPTF BVC 168 .70 2.00 .69 .50 1.12 1/4 NPTF BVC 106 .80 2.50 .81 .50 1.12 1/4 NPTF BVC 30 1.10 3.09 1.44 .62 1.12 1/4 NPTF C

VACUUM CUPS

Cleated Model No. Approx. Area in2 A (O.D.) B C D E StyleVC 36B .30 1.00 .36 .25 .56 .25 AVC 2EA .37 1.37 1.06 .31 .62 1/8 NPTM CVC 59 1.30 2.00 .62 .25 1.56 1/4 NPTF BVC 49 2.10 2.44 1.94 .81 1.04 1/4 NPTF CVC 27A 2.40 3.25 1.06 .44 2.25 1/4 NPTF BVC 27 3.40 4.25 1.00 .50 3.00 1/4 NPTF BVC 63 5.60 4.75 1.18 1.00 1.62 3/8 NPTF BVC 34 10.40 6.25 1.18 .81 5.00 3/8 NPTF B

Ultraminiature Model No. Approx. Area in2 A (O.D.) B C D E OptionsVC-VI 062 .003 .063 .126 .006 .055 .025 B/ESDVVC-VI 125 .02 .125 .120 .020 .070 .030 B/ESD/R/UVVC-VI 250 .05 .250 .200 .040 .100 .045 B/ESD/R/UVVC-VI 375 .11 .375 .250 .070 .130 .060 B/ESD/R/UVVC-VI 500 .19 .500 .300 .110 .160 .060 B/ESD/R/UVVC-VI 625 .30 .625 .310 .110 .160 .060 B/ESD/R/UVVC-VI 750 .44 .750 .320 .130 .160 .060 B/ESD/R/UV

Oval Model No. Approx. Area in2 A (O.D.) B C D E StyleVC 89 1.75 1.12x2.75 .87 .70 .78 1/4 NPTF BVC 83 4.50 1.56x4.09 .94 .50 1.15x3.6 1/4 NPTF BVC 87BL .44 1.70x1.50 .50 .20 .62 1/8 NPTF AVC 183 6.00 2.0x6.0 1.00 .39 1.25x5.2 1/4 (2 Ports) BVC 90 12.00 3.0x8.0 1.12 .53 2.12x7.1 3/8 (2 Ports) B

Bellows Model No. Approx. Area in2 A (O.D.) B C D E StyleVC B6 .01 .25 .43 .15 .15 .06 D-1VC B10-5 .04 .42 .62 .21 .32 .15 D-1VC B3 .05 .50 .56 .38 .31 .15 D-1VC B15 .07 .62 .81 .40 .35 .14 D-1VC B2 .11 .75 .68 .50 .51 .25 D-1VC 33A5 .16 .75 1.00 .75 .69 .44 D-3VC B20P .15 .87 .75 .50 .57 .20 D-1VC 33A3 .20 .90 1.02 .62 .69 .44 D-2VC 124 .24 1.00 1.37 .62 .62 .37 D-1VC B1 .25 1.20 .85 .77 .56 1/8 NPTF D-1VC 33A2 .25 1.27 1.00 .87 .69 1/4 NPTF D-2VC 33A .40 1.37 1.50 1.00 .65 1/4 NPTF D-3VC 32C .78 2.00 1.68 .81 .75 1/4 NPTF D-1VC 32D 1.00 2.00 1.86 1.12 .75 1/4 NPTF D-2VC 32B 2.00 2.75 2.00 1.28 1.00 1/4 NPTF D-1VC 130 4.90 3.31 2.38 2.18 2.38 3/4 NPTF D-4VC 32-3.5x5.0 3.5x5.0 1.75 1.25 2.0x3.5 3/8 NPTF D-1

OPTIONSB = Non-Marking Static Dissipative. Temperature range: -4°F to 248°F (-20°C to 120°C)ESD = ESD Safe High Temperature. Temperature range: -67°F to 446°F (-55°C to 250°C)R = Red Silicone High Temperature. Temperature range: -67°F to 482°F (-55°C to 250°C)U = Blue Silicon High Temperature. Temperature range: -67°F to 482°F (-55°C to 350°C)V = Probe (cup holders) available

21Vaccon Co. Inc. 800-848-8788

All dimensions shown in inches

Many other cup sizesavailable on request.

Page 24: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

22Vaccon Co. Inc. 800-848-8788

IN-LINE VACUUM FILTERSADDED PROTECTION FOR EXTREME – ADVERSE CONDITIONS!

Compact in-line filters for adverse conditionsprovide the added protection of 10 micron filtrationand have a 150 psi pressure rating. Filters areconstructed from rugged injection molded nylonand plastic. Vaccon offers eight different designconfigurations for maximum placement versatilityand easy installation.

FEATURES

High Flow

10 Micron Filtration

8 Models

Vaccon’s unique single stage vacuum pumps do not require filters for maximum operating efficiency.Filters are recommended for use in only the most adverse operating conditions to provide additional,in-line protection and user satisfaction.

Part Number Description Ports A B C D Replacement ElementVF125LPM 1/8" Male Low Profile 1/8"NPTMVF250LPM 1/4" Male Low Profile 1/4"NPTM 2.4 3.1 2.0 1.9 RE1VF375LPM 3/8" Male Low Profile 3/8"NPTMVF250F 1/4" Female Filter 1/4"NPTF 3.7 3.0 3.25 1.9V375F 3/8" Female Filter 3/8"NPTF 3.7 3.0 3.25 1.9

RE1-L

VF500F 1/2" Female Filter 1/2"NPTF 5.35 3.6 4.8 2.95VF750F 3/4" Female Filter 3/4"NPTF 5.35 3.6 4.8 2.95

RE2

VF1000F 1" Female Filter 1"NPTF 6.35 5.0 5.6 4.1 RE3

VF125LPM (1.9 OZ)VF250LPM (2 OZ)VF375LPM (2 OZ)

VF500F (5.6 OZ)VF750F (5.6 OZ)VF1000F (7.8 OZ)

Page 25: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

SPECIFICATIONS

DIMENSIONS CONSTRUCTION MAX. OP. NOISE LEVELSILENCER PRESSURE MEDIA measured 4.5 ft.

A B Ø C D BODY BAFFLE SCREEN FILTERfrom silencer

AA2 1.052 .604 1/8" NPT .234 NYLON NYLON NYLON FELT 150 PSIG AIR 68dBA

AA4 1.265 .706 1/4" NPT .326 NYLON NYLON NYLON FELT 150 PSIG AIR 68dBA

AA6 1.833 .955 3/8" NPT .429 NYLON NYLON NYLON FELT 150 PSIG AIR 72dBA

FA51-1/4 5.75 3.25 1/4" NPT .5 STEEL FOAM STEEL PAPER 150 PSIG AIR 72dBA

FA51-3/8 5.75 3.25 3/8" NPT .5 STEEL FOAM STEEL PAPER 150 PSIG AIR 72dBA

FA51-1/2 5.75 3.25 1/2" NPT .5 STEEL FOAM STEEL PAPER 150 PSIG AIR 72dBA

ST4A2 2.65 1.00 1/4" NPT .30 ALUM. — — FELT 150 PSIG AIR 68dBA

STAA4 3.00 .75 1/4" NPT .40 ALUM. FELT NYLON FELT 150 PSIG AIR 68dBA

ST4 2.35 .75 1/4" NPT .4 ALUM. — — FELT 150 PSIG AIR 68dBA

ST6A 3.95 1.00 3/8" NPT .4 ALUM. — — FELT 150 PSIG AIR 68dBA

ST8A 3.95 1.00 1/2" NPT .4 ALUM. — — FELT 150 PSIG AIR 68dBA

ST6B 5.20 1.25 3/8" NPT .4 ALUM. — — FELT 150 PSIG AIR 68dBA

ST8B 5.20 1.25 1/2" NPT .4 ALUM. — — FELT 150 PSIG AIR 76dBA

ST12C 7.44 2.00 3/4" NPT .5 ALUM. — — FELT 150 PSIG AIR 76dBA

ST16C 7.44 2.00 1" NPT .5 ALUM. — — FELT 150 PSIG AIR 76dBA

NO

ISE

LE

VE

LS A

RE

BA

SE

D O

N T

HE

SIL

EN

CE

R B

EIN

GAT

TAC

HE

D T

O A

VAC

CO

N V

EN

TUR

I PU

MP.

NYLON NYLON

ACCESSORIES

VACCON SILENCERS

Vaccon silencers are extremely effective in reducing air exhaust noise from venturi pumps and other pneumatic devices.The AA, ST, and FA51 Series reduce noise levels by up to 30 dB while allowing high flow rates with minimal back pressure.

Compact, lightweight, these silencers haveexcellent noise reducing characteristics withminimal resistance to air flow. AA Seriessilencers are almost one third smaller thancomparable products providing considerablespace savings. The large surface of the felt ele-ment resists contamination far more than othermaterials such as sintered bronze, steel mesh,or porous polyethylene.

The FA51 Series silencers offer remarkablenoise reduction for high volume exhaust appli-cations without causing back pressure.Silencers are ideal for quieting large air valvesthat must exhaust quickly to maintain highcycle rates. Vaccon uses the FA51 silencers ontheir high flow venturi vacuum pumps whereeven small amount of back pressure woulddecrease performance.

A threaded connection provides easy installa-tion for replacement element, P/N RF51

The ST-Series’ straight-through design elimi-nates clogging by allowing contaminants topass directly through the silencer. Eachsilencer is tuned in proportion to its exhaustflow to minimize noise and reduce frequency.As air passes through the silencer, noise isabsorbed by the dense felt liner. This reduceshigh pitch exhaust noise to a gentle, lowfrequency flow of air.

Even in the most adverse conditions, contami-nants pass through the silencer making the ST- Series ideal for silencing venturi pumpsthat are continuously ingesting dirt and debris.

AA Series FA51 Series ST Series

23Vaccon Co. Inc. 800-848-8788

Page 26: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

24Vaccon Co. Inc. 800-848-8788

SPECIFICATION DRAWINGSMIN SERIES VACUUM PUMPS

VP00-60H VP01-60H, VP1QR-60H

FASTBREAK

VP0X-60H VPIX

VP2X VP8X-200M, H

7.56

4.00

Page 27: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

25Vaccon Co. Inc. 800-848-8788

SPECIFICATION DRAWINGSMID SERIES VACUUM PUMPS 60 90 100 150

VP10 VP20

VP61

Weight - 14.8 oz.Exhaust Port - 1/4" NPTSilencer - AA4

Page 28: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

26Vaccon Co. Inc. 800-848-8788

SPECIFICATION DRAWINGSMAX SERIES VACUUM PUMPS 200, 250, 300, 350

VP80-200M,H

VP80-250M,H

VP90-300M,HVP90-350M, H

Weight - 9.4 oz.Exhaust Port - 3/8" NPTSilencer - ST6A

Weight - 24.3 oz.Exhaust Port - 1/2" NPTSilencer - FA51-1/2

Weight - 24.3 oz.Exhaust Port - 1/2" NPTSilencer - FA51-1/2

Page 29: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

27Vaccon Co. Inc. 800-848-8788

SPECIFICATION DRAWINGSMANIFOLD, HIGHVAC, DUAL-VAC

Manifold

Highvac Dual-Vac

ModelDIMENSIONS

A B C D E F G H I J K L M SilencerAir Supply Vacuum Exhaust MTG

Port Port Port Hole Ø

HVP100 .375 2.25 4.58 3.20 1.78 * .078 1.50 .75 1/4 1/8 1/4 .125 AA4NPT NPT NPT

HVP200 .750 4.00 7.56 4.00 2.20 1.50 .20 2.80 1.00 1/4 1/4 1/2 .206 ST8ANPT NPT NPT

HVP300 .750 4.00 9.80 5.00 2.50 1.50 .20 2.75 1.00 3/8 1/4 1/2 .206 ST8BNPT NPT NPT

* F1=.6

Page 30: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

28Vaccon Co. Inc. 800-848-8788

SPECIFICATION DRAWINGSJ SERIES

ModelDIMENSIONS

A B C D E F Recommended Length(in.) (in.) (in.) NPT NPT NPT Silencer* w/Silencer

60M 3/4 2 3/4 3/4 1/8 1/8 1/4 AA4 4 1/890M ST4 4 7/8100M 3/4 2 3/4 3/4 1/8 1/8 1/4 AA4 4 1/8150M ST4 4 7/8

1501 1/4 4 1 1/4 3/8 3/8 AA6 5 7/8

ST6A 8

2001 1/4 4 1 1/4 3/8 3/8 AA6 5 7/8

ST6A 8FA51-3/8 9 3/4

2501 1/4 4 1 1/4 3/8 3/8 FA51-3/8 9 3/4

ST6B 8

3001 1/4 5 1 3/8 3/8 3/8 FA51-3/8 10 3/4

ST6B 10 1/4

3501 1/2 6 1 1/2 1/2 1/2 1/2 FA51-1/2 11 3/4

ST8B 11 1/4

*Note: For ultra quiet operation the STAA4 Silencer can be used on all of the M series models. All M series w/STAA4 length = 6.00".

ModelDIMENSIONS

A B C D E F G H I J Silencer SilencerBarrel Collar Input Barrel Collar Thread Thread Length

ID Length (NPTF) OD OD ID NPTF ID NPTFVDF100 .100 7/8 1 1/2 3/4 1/8 3/4 1 1/4 1 1/2 1/4 1/4 ST4 2.50VDF150 .150 7/8 1 1/2 3/4 1/8 3/4 1 1/4 1 1/2 1/4 1/4 ST4 2.50VDF200 .20 7/8 1 1/2 3/4 1/8 3/4 1 1/4 1 1/2 1/4 1/4 ST4 2.50VDF250 .25 7/8 1 1/2 3/4 1/8 3/4 1 1/4 1 1/2 1/4 1/4 ST4A2 2.65VDF375 .375 1 1/2 1 3/4 7/8 3/8 1 1 1/2 2 3/4 1/2 1/2 ST8B 5.20VDF500 .50 1 1/2 2 1 3/8 1 1/4 2 2 1/2 3/4 1/2 ST12C 7.50VDF750 .75 1 1/2 2 1 1/2 1 1/2 2 1/4 3 3/8 1 3/4 ST16C 7.50

VDF SERIES

A

Page 31: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

29Vaccon Co. Inc. 800-848-8788

SPECIFICATION DRAWINGSCDF SERIES

ModelDIMENSIONS

I.D. (NPTF)A B C D E F G H I

DF1-3 1/8 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF2-3 1/4 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF3-3 3/8 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF3-6 3/8 1 1/4 3/4 3 1/2 3/4 1 1 3/4 .5 1/8DF5-3 1/2 1 1/2 1 5 1/2 1 1 1/4 3 1/4 5/8 1/4DF5-6 1/2 1 1/2 1 5 1/2 1 1 1/4 3 1/4 5/8 1/4DF7-3 3/4 2 1 1/4 7 1/2 1 1/2 2 4 1 3/8DF7-6 3/4 2 1 1/4 7 1/2 1 1/2 2 4 1 3/8DF10-3 1 2 1/4 1 1/2 7 1/2 1 1/2 2 4 1 3/8DF10-6 1 2 1/4 1 1/2 7 1/2 1 1/2 2 4 1 3/8DF15-3 1 1/2 2 3/4 2 7 1/2 1 1/2 2 4 1 3/8DF15-6 1 1/2 2 3/4 2 7 1/2 1 1/2 2 4 1 3/8DF20-3 2 3 1/4 2 1/2 7 1/2 1 1/2 2 4 1 3/8DF20-6 2 3 1/4 2 1/2 7 1/2 1 1/2 2 4 1 3/8DF30-6 3 4 1/4 3 1/2 10 1/2 2 3 5 1/2 1 1/2 1/2

ModelDIMENSIONS

I.D. (NPTF) (NPTF)A B C D E F G H J

CDF100 1/8 1 1/4 9/16 2 1 3/4 0.13 1/8 —

CDF200 1/4 1 1/4 9/16 2 1 3/4 0.13 1/8 —

CDF500H† 1/2 1 1/2 1 4 1/8 2 5/8 1 1/2 0.2 1/4 1/2

CDF750H† 3/4 2 1 1/4 4 1/8 2 5/8 1 1/2 0.2 1/4 1

CDF1000H† 1 2 1/4 1 1/2 4 1/8 2 5/8 1 1/2 0.2 1/4 1 1/4

CDF1500H 1 1/2 2 3/4 2 4 1/8 2 5/8 1 1/2 0.2 3/8 2

CDF2000H 2 3 1/4 2 1/2 4 1/8 2 5/8 1 1/2 0.2 3/8 2 1/2

Jam nut is used to secure adjustment All dimensions in inches

These products will operate with as little as 3 psi All dimensions in inches

OPTIONAL THREADED EXHAUST ATTACHMENTS FORMODELS CDF500H, 750H 1000

THREADED † C* D* F*EXHAUST MODELPART NO.

EPT-100 CDF500H 1" NPT 4 5/8" 2"

EPT-107 CDF750H 1" NPT 5 1/8" 2 1/2"

EPT-125 CDF1000H 1 1/2" NPT 4 5/8" 2"

DF SERIES

Page 32: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

30Vaccon Co. Inc. 800-848-8788

WHERE:F is the weight of the object in pounds

(lbs) multiplied by a safety factor(See page 12)

P is the expected vacuum level in PSI,remember to convert “Hg” to PSI bydividing by 2

A is the area of the vacuum cup in sq.inches. Use the equation, Area = πd2

4

GUIDE TO VACUUM PUMP SELECTION

There are two types of vacuum applications

PICK AND PLACE – MATERIAL HANDLING

Referred to here as the lifting, gripping, rotating and positioning of an object throughthe use of a vacuum pump and vacuum cup

Use the Equation: Force = Pressure x Area

to Determine:

1. Lifting capacity of the pump and cup,

2. Required vacuum area, i.e. diameter of cup,

3. Required vacuum level of vacuum pump.

2 Vacuum Level Ranges - “H” for High Vacuum and “M” for Medium Vacuum.

“H” - Series (28'' Hg) for non-porous material togenerate maximum holding force.

Hint: Try P = 12.5 PSI (25" Hg) as a starting valuewhen using equation, F = P x A.

Systems Speed:Cycle rate of the pump and cup system is determined by the evacuation speed of the venturi, see “Vessel Evacuation” below.

“M” - Series (20'' Hg) for porous material togenerate medium holding force while overcomingleakage and saving compressed air.

Hint: Try P = 8 PSI (16" Hg) as a starting valueusing equation, F = P x A.

INEXACT SCIENCE

When handling porous materials such as corrugatedor heavy fabric it is hard to choose the exact pumprequired because the leakage rate is not normallyknown. Therefore, it is best to run a benchtop trial totest the ability of the pump to overcome the leakage.For existing systems, consult Vaccon for the equiva-lent pump size. In new applications, take advantage ofVaccon’s free 30 day trial to ensure proper pumpselection.

Increase safety, reliability and speed by using onesmall Fastvac pump at each cup location. Should onecup fail the others will not be affected.

VESSEL EVACUATION

In many process applications it is necessary to evacuate avessel for the purpose of purging gases, leak testing,degassing viscous fluids or the vessel may simply be thelength of tubing between the pump and cup. Knowing theevacuation speed will help determine process completiontime or the production rate of a pick and place system.

Evacuation speed is directly related to the vacuum flow ofthe pump. To use the chart of evacuation speed listed foreach venturi identify operating conditions;

Notice that the charts are based on a one cubic foot vol-ume. Evacuation speed is linear with volume, therefore a 2cu. ft. volume will take twice as long to evacuate.

1. Volume to be evacuated (Cu. Ft.), 1728 cu, in. = 1 cu. ft.

2. Desired vacuum level (“Hg),

3. Time to reach vacuum level (seconds).

Page 33: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

NOTES

31Vaccon Co. Inc. 800-848-8788

Page 34: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

32Vaccon Co. Inc. 800-848-8788

NOTES

Page 35: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

SPECIALLY ENGINEERED PRODUCTS

Vaccon's engineering expertise and manufacturing capabilities pro-vide custom solutions to specific problems. By modifying standardproducts or creating and developing new devices, Vaccon pridesitself in servicing the client's needs.

(A) SIZE - P/N: 52-1005, Miniature venturi for degassing water. Sizeis 9/16" dia. x 1" long, generates a vacuum level of 20" Hg at anoperating pressure of 21 PSI.

(B) SHAPE - P/N: CE-1, Integral Vacuum Mandrel CollectionSystem-Vaccon engineered a special DF model to mate directly ontocustomers product. Holds rivet by vacuum, removes spent mandrelby sucking into plastic bottle at rear of tool.

(C) MATERIAL - P/N: JS-250-PVC, Plastic body venturi for corro-sive battery filling equipment.

(D) SYSTEM DESIGN - P/N: VAC-90H, Custom vacuum housingusing cartridge venturi. Vaccon manufactures component and shipscomplete 100% tested.

GLOSSARY OF VACUUM TERMS AND DEFINITIONS

AIR CONSUMPTION: The volume of compressed air required to power the pump. Also measured in SCFM. Consumptionvaries directly with input pressure. A 1hp compressor can supply approximately 4SCFM @ 80PSI.

ATMOSPHERIC PRESSURE: The atmosphere that surrounds the earth can be considered a reservoir of low pressure air.It's weight exerts a pressure that varies with temperature, humidity, and altitude. Atmospheric pressure at sea level: 29.92"Hg or 760 mm Hg.

BAROMETER: Device, usually mercury filled, that measures the atmospheric pressure.

"HG (INCHES OF MERCURY): A unit used to measure vacuum level. 29.92" Hg =14.7 psi is the maximum vacuum possibleon a standard day. 1"Hg =13.6"H2O.

SCFM (STANDARD CUBIC FEET PER MINUTE): Air at sea level 59°F 50% humidity.

VENTURI'S / EJECTORS: Same as air-powered vacuum pump, just a different name.

VACUUM FLOW: The volume of free air induced by the vacuum pump per unit of time (standard cu. ft/minute).

VACUUM LEVEL: The magnitude of the suction created by the vacuum pump. The unit of measure is mm Hg. Vacuum levelis effected by elevation and barometric pressure. For each 1,000 feet of elevation, vacuum decreases by approximately1" Hg.

VACUUM FORCE: Equal to the vacuum level times the area of the vacuum surface, i.e. holding area of a vacuum cup.

Page 36: Vacuum Pumps, Manifolds, Cups, and AccessoriesVaccon venturi pumps are designed to operate at peak efficiency at 80 PSI. Systems requiring operation at 60 PSI should be ordered with

Available Worldwide

To ensure customer satisfaction and proper pump selection,Vaccon offers a 30 day free trial with no cost or obligation

Serving the Automation and Process Control Industries for over 20 years.

North AmericanSales Office

Vaccon Co., Inc.PO Box 324

32 Rear Spring StreetMedfield, MA 02052 USA

Tel 508-359-7200Fax 508-359-0177

e-mail: [email protected]

European Sales Office

KV Ltd.Presley Way

CrownhillMilton Keynes

BuckinghamshireMK8 0HB, England

Tel +(44) 01908 561515Fax +(44) 01908 561227

Your Local Distributor

1/97

http://www.vaccon.com