Page 1: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Semester Dec – Apr 2010

Page 2: ULTRAVIOLET-VISIBLE SPECTROSCOPY

In this lecture, you will learn:Molecular species that absorb UV/VIS

radiationAbsorption process in UV/VIS region in terms

of its electronic transitionsImportant terminologies in UV/VIS

spectroscopy

Page 3: ULTRAVIOLET-VISIBLE SPECTROSCOPY

MOLECULAR SPECIES THAT

ABSORB UV/VISIBLE RADIATION

Organic compounds

Inorganic species

Charge transfer

Page 4: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Definitions:Organic compound

Chemical compound whose molecule contain carbon.E.g. C6H6, C3H4

Inorganic speciesChemical compound that does not contain carbon.E.g. transition metal, lanthanide and actinide elementsCr, Co, Ni, etc..

Charge transferA complex where one species is an electron donor and the

other is an electron acceptor.E.g. iron(III) thiocyanate complex

Page 5: ULTRAVIOLET-VISIBLE SPECTROSCOPY

NOTE: Transition metals - groups IIIB through IB

Page 6: ULTRAVIOLET-VISIBLE SPECTROSCOPY

UV-VIS ABSORPTIONIn UV/VIS spectroscopy, the transitions which

result in the absorption of EM radiation in this region are transitions btw electronic energy levels.

Page 7: ULTRAVIOLET-VISIBLE SPECTROSCOPY

- In molecules, not only have electronic level but also consist of vibrational and rotational sub-levels. - This result in band spectra.

Page 8: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Type of Transitions3 types of electronic transitions

σ, п and n electronsd and f electronsCharge transfer electrons

Page 9: ULTRAVIOLET-VISIBLE SPECTROSCOPY

What is σ, What is σ, and n and n electrons?electrons?

Page 10: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Sigma ()electron

Electrons involved in single bonds such as those between carbon and hydrogen in alkanes.

These bonds are called sigma (σ) bonds.The amount of energy required to excite

electrons in σ bond is more than UV photons of wavelength. For this reason, alkanes and other saturated compounds (compounds with only single bonds) do not absorb UV radiation and therefore frequently very useful as transparent solvents for the study of other molecules. For example, hexane, C6H14.

Page 11: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Pi () electronElectrons involved in double and triple bonds

(unsaturated). These bonds involve a pi (п) bond. For example: alkenes, alkynes, conjugated

olefins and aromatic compounds.Electrons in п bonds are excited relatively

easily; these compounds commonly absorb in the UV or visible region.

Page 12: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Examples of organic molecules containing п bonds.

CH2CH3

C

CC

C

CC

H

H

H

H

H

H

C C HH3C

C C

C CH H

H

H

H

H

ethylbenzene benzen

e

propyne

1,3-butadiene

Page 13: ULTRAVIOLET-VISIBLE SPECTROSCOPY

n electronElectrons that are not involved in bonding

between atoms are called n electrons. Organic compounds containing nitrogen,

oxygen, sulfur or halogens frequently contain electrons that are nonbonding.

Compounds that contain n electrons absorb UV/VIS radiation.

Page 14: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Examples of organic molecules with non-bonding electrons.

NH2

C

R

O C CH

H

H3C

Br

aminobenzene

Carbonyl compoundIf R = H aldehydeIf R = CnHn ketone

2-bromopropene

Page 15: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Absorption by Organic Compounds

UV/Vis absorption by organic compounds requires that the energy absorbed corresponds to a jump from occupied orbital unoccupied orbital.

Generally, the most probable transition is from the highest occupied molecular orbital (HOMO) to the lowest unoccupied molecular orbital (LUMO).

Page 16: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Electronic energy levels diagram

Occupied levels

Unoccupied levels

Page 17: ULTRAVIOLET-VISIBLE SPECTROSCOPY

* transitionsNever observed in normal UV/Vis work.The absorption maxima are < 150 nm.The energy required to induce a σ σ*

transition is too great (see the arrow in energy level diagram)

This type of absorption corresponds to breaking of C-C, C-H, C-O, C-X, ….bonds

vacuum UV region σ σ*

Page 18: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Saturated compounds must contain atoms with unshared electron pairs.

Compounds containing O, S, N and halogens can absorb via this type of transition.

Absorptions are typically in the 150 -250 nm region and are not very intense.

ε range: 100 – 3000 Lcm-1mol-1

n * transitions

Page 19: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Some examples of absorption due to n σ* transitions

Compound λmax (nm) εmax

H2O 167 1480CH3OH 184 150CH3Cl 173 200CH3I 258 365(CH3)2O 184 2520CH3NH2 215 600

Page 20: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Unsaturated compounds containing atoms with unshared electron pairs

These result in some of the most intense absorption in 200 – 700 nm region.

ε range: 10 – 100 Lcm-1mol-1

n * transitions

Page 21: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Unsaturated compounds to provide the orbitals.

These result in some of the most intense absorption in 200 – 700 nm region.

ε range: 10oo – 10,000 Lcm-1mol-1

* transitions

Page 22: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Some examples of absorption due to n * and * transitions

Page 23: ULTRAVIOLET-VISIBLE SPECTROSCOPY

CHROMOPHORE

Unsaturated organic functional groups that absorb in the UV/VIS region are known as chromophores.

Page 24: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 25: ULTRAVIOLET-VISIBLE SPECTROSCOPY

AUXOCHROMEGroups such as –OH, -NH2 & halogens that

attached to the doubley bonded atoms cause the normal chromophoric absorption to occur at longer λ (red shift). These groups are called auxochrome.

Page 26: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Effect of Multichromophores on Absorption

More chromophores in the same molecule cause bathochromic effect ( shift to longer ) and hyperchromic effect(increase in intensity)

In the conjugated chromophores * electrons are delocalized over larger number of atoms causing a decrease in the energy of * transitions and an increase in due to an increase in probability for transition.

Page 27: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Factors that influenced the λ:i) Solvent effects (shift to shorter λ: blue shift)ii) Structural details of the molecules

Other Factor that Influenced Absorption

Page 28: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Important terminologies

hypsochromic shift (blue shift)- Absorption maximum shifted to shorter λ

bathochromic shift (red shift)- Absorption maximum shifted to longer λ

Page 29: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Terminology for Absorption Shifts

Nature of Shift Descriptive Term

To Longer Wavelength Bathochromic

To Shorter Wavelength Hypsochromic

To Greater Absorbance Hyperchromic

To Lower Absorbance Hypochromic

Page 30: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Absorption by Inorganic Species

Involving d and f electrons absorption

3d & 4d electrons- 1st and 2nd transition metal series e.g. Cr, Co, Ni & Cu- Absorb broad bands of VIS radiation- Absorption involved transitions btw filled and unfilled d-orbitals with energies that depend on the ligands, such as Cl-, H2O, NH3 or CN- which are bonded to the metal ions.

Page 31: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 32: ULTRAVIOLET-VISIBLE SPECTROSCOPY

4f & 5f electrons- Ions of lanthanide and actinide elements- Their spectra consists of narrow, well-defined characteristic absorption peaks

Page 33: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 34: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Charge Transfer Absorption

Absorption involved transfer of electron from the donor to an orbital that is largely associated with the acceptor.

an electron occupying in a σ or orbital (electron donor) in the ligand is transferred to an unfilled orbital of the metal (electron acceptor) and vice-versa.

e.g. red colour of the iron(III) thiocyanate complex

Page 35: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 36: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Important components in a UV-Vis spectrophotometer

Source lamp

Sample holder λ selector Detecto

rSignal

processor & readout

1 23 4

5

UV region: - Deuterium lamp; H2 discharge tube

Visible region: - Tungsten lamp

Quartz/fused silica

Glass/quartz

Prism/monochromator

Prism/monochromator

Phototube,PM tube, diode array

Phototube,PM tube, diode array

Page 37: ULTRAVIOLET-VISIBLE SPECTROSCOPY

UV-VIS INSTRUMENT

Single beamDouble beam

Page 38: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 39: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Single beam instrument

One radiation sourceFilter/monochromator (λ selector)CellsDetectorReadout device

Page 40: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Disadvantages:

Two separate readings has to be made on the light. This results in some error because the fluctuations in the intensity of the light do occur in the line voltage, the power source and in the light bulb btw measurements.

Changing of wavelength is accompanied by a change in light intensity. Thus spectral scanning is not possible.

Single beam instrument

Page 41: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Double-beam instrument with beams separated in space

Page 42: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Advantages:

1. Compensate for all but most short-term fluctuations in the radiant output of the source as well as for drift in the transducer and amplifier

2. Compensate for wide variations in source intensity with λ

3. Continuous recording of transmittance or absorbance spectra

Double beam instrument

Page 43: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Quantitative Analysis

The fundamental law on which absorption methods are based on Beer’s law (Beer-Lambert law).

Page 44: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Measuring absorbance

You must always attempt to work at the wavelength of maximum absorbance (max)

This is the point of maximum response, so better sensitivity and lower detection limits.

You will also have reduced error in your measurement.

Page 45: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 46: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Quantitative Analysis

Calibration curve method Standard addition method

Page 47: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Calibration curve method

A general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of std sample of known concentration

Page 48: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard Calibration Curve

How to measure the concentration of unknown? Practically, you have measure the absorbance of your

unknown. Once you know the absorbance value, you can just read the corresponding concentration from the graph .

Concentration, ppm

Page 49: ULTRAVIOLET-VISIBLE SPECTROSCOPY

How to produce standard calibration curve?

Prepare a series of standard solution with known concentration.

Measure the absorbance of the standard solutions.

Plot the graph A vs concentration of std.

Find the ‘best’ straight line by using least-squares method.

A

Page 50: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Finding the Least-Squares Line

Concentrationxi

Absorbanceyi

x2i y2i xiyi

5 0.20110 0.42015 0.65420 0.86225 1.084

xi yi xi2 yi

2 xiyi

N – is the number of points used

N = 5

Page 51: ULTRAVIOLET-VISIBLE SPECTROSCOPY

The calculation of the slope and intercept is simplified by defining three quantities Sxx, Syy and Sxy.

Sxx = (xi – x)2 = xi2– ( xi)2 …… (1)

Syy = (yi – y)2 = yi2– ( yi)2 ……(2)

Sxy = (xi – x) (yi – y)2 = xiyi – xi yi

…(3)

N

N

N

Page 52: ULTRAVIOLET-VISIBLE SPECTROSCOPY

The slope of the line, m:

m = Sxy

Sxx

The intercept, b:

b = y - mx

Thus, the equation for the least-squares line is

y = mx + b

Page 53: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Concentrationx

y = mx + b

510152025

From the least-squares line equation, you can calculate the new y values by substituting the x value.

Then plot the graph.

Page 54: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Most linear regression implementations have an option to “force the line through the origin,” which means forcing the intercept of the line through the point (0,0). This might seem reasonable, since a sample with no detectable concentration should produce no response in a detector, but must be used with care.

HOWEVER, forcing the plot through (0,0) is not always recommended, since most curves are run well above the instrumental limit of detection (LOD). Randomly, adding a point (0,0) can skew the curve because the instrument’s response near the LOD is not predictable and is rarely linear. As illustrated next page, forcing a curve through the origin can, under some circumstances, bias results.

Page 55: ULTRAVIOLET-VISIBLE SPECTROSCOPY
Page 56: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard addition method

used to overcome matrix effectinvolves adding one or more increments of a

standard solution to sample aliquots of the same size.

each solution is diluted to a fixed volume before measuring its absorbance

Page 57: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Concentration, ppm

Absorbance

Page 58: ULTRAVIOLET-VISIBLE SPECTROSCOPY

How to produce standard addition curve?

1. Add same quantity of unknown sample to a series of flasks

2. Add varying amounts of standard (made in solvent) to each flask, e.g. 0,5,10,15mL)

3. Fill each flask to line, mix and measure

Page 59: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Single-point standard addition method

Multiple additions method

Page 60: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard addition- if Beer’s law is obeyed,

A = εbVstdCstd + εbVxCx

Vt Vt

= kVstdCstd + kVxCx

k is a constant equal to εb

Vt

Page 61: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard Addition - Plot a graph: A vs Vstd

A = mVstd + b

where the slope m and intercept b are:

m = kCstd ; b = kVxCx

Page 62: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Cx can be obtained from the ratio of these two quantities: m and b

b = kVxCx

m kCstd

Cx = bCstd

mVx

Page 63: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard Addition

For single-point standard addition

A1 = εbVxCx Vt A2 = εbVxCx + Vt

εbVsCs Vt

Eq. 1

Eq. 2

Absorbance of diluted sample

Absorbance of diluted sample + std

Page 64: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard AdditionFor single-point standard addition

Dividing the 2nd equation by the first & then rearrange it will give:

Cx = A1 Cs Vs (A2 – A1 ) Vx

Page 65: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Example Standard Addition (single point addition)

A 2.00-mL urine specimen was treated with reagent to generate a color with phosphate, following which the sample was diluted to 100 mL. To a second 2.00mL sample was added exactly 5.00mL of a phosphate solution containing 0.03 mg phosphate /mL, which was treated in the same way as the original sample. The absorbance of the first solution was 0.428, while the second one was 0.538. Calculate the concentration of phosphate in milligrams per millimeter of the specimen.

Example 14-2 (page 376)

Page 66: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Solution:

Cx = (0.428) (0.03 mg PO43-/mL) (5.00mL) (0.538 – 0.428)(2.00mL)

= 0.292 mg PO43- / mL sample

Page 67: ULTRAVIOLET-VISIBLE SPECTROSCOPY

Standard, mL Absorbance0.0 0.201

10.0 0.29220.0 0.37830.0 0.46740.0 0.554

The concentration of an unknown chromium solution was determined by pipetting 10.0mL of the unknown into each of five 50.0 mL volumetric flasks. Various volumes of a standard containing 12.2 ppm chromium were added to the flasks and then the solutions were diluted to the mark.

Determine the concentration of chromium (in ppm) in the unknown.

Exercise