tlg titus thorn

16
Titus A powerful range of fluorescent luminaires designed for sport and industrial applications

Upload: vietdquoc

Post on 29-Nov-2015

202 views

Category:

Documents


3 download

DESCRIPTION

Tiêu chuẩn

TRANSCRIPT

TitusA powerful range of fluorescent luminaires designed for sport and industrial applications

Introduction

The Titus range of fluorescent luminaires for industrial and sports lighting applications has quickly gained wide acceptance and there are Titus installations in all parts of the world

The basic thinking that went into the first Titus range is still valid some five years on but our technical departments now allow us to update the range with significant benefits to both user and installer.

Titus offers many new benefitsHigher output lamps The range includes the use of 80W lamps for optimum performance. With up to 24,600 initial lamp lumens per luminaire, Titus now offers a high quality alternative to conventional high and low bay fittings with high pressure discharge lamps.

Energy savingsDimmable control gear options, allow the luminaires to be easily linked to presence or daylight detectors, resulting in potential energy saving benefits.

Longer life in industry Titus Industry luminaires are supplied with heavy duty electronic ballasts designed to operate in harsh environments; for example they have a life of up to 100,000 + hours at high ambient temperatures and can withstand voltage peaks of up to 4kV.

Improved SafetyEmergency lighting is required to operate automatically when a lighting circuit loses the mains supply. Integral emergency versions of Titus are offered as standard in the range.

s Titus Industry

t Titus Sport

Contents

Performance, Efficiency, Comfort - PEC 3

Indoor sports applications 4 - 7

Industrial applications 8 - 11

Titus Sport ordering guide 12 - 13

Titus Industry ordering guide 14 - 15

2

Tennis hall in the French city “Thorigné Fouillard” Photograph by Pilam ©

Titus evokes the spirit of Thorn Lighting’s dynamic, results-orientated PEC programme

Performance, Efficiency and Comfort (PEC) – for a better lit environment

Performance: Providing the best visual effectiveness

•Fromaluminairethatislessthan 250mm wide, MIRO reflectors offer precise light distributions (wide and asymmetric) to give good vertical illuminance

•Whencomparedtosinglepoint discharge fittings with high pressure discharge lamps, the linear nature of Titus provides less glare and distinct shadowing, offering a much improved light quality

•ColourrenderingofRa85+provides excellent visibility and satisfies the requirements of the European Directive EN 12464 for the lighting of workplaces and meets Sport Guidance recommendations

The programme is based on the principle that Performance, Efficiency and Comfort determine the effectiveness of lighting, its impact on the people using it, and its impact on the natural environment. Titus delivers the right light on the right place at the right time.

Efficiency: Conserving energy and effort, reducing CO2 emissions and waste, providing lighting that is practical and efficient to install, operate and maintain

•HighoutputT16lampswithtypically high efficacies in the 80 lumens per watt bracket combine with high frequency control gear to ensure energy efficient lighting

•Tituscanbeusedinconjunctionwith automatic control systems that react to the presence or absence of people and/or to the amount of daylight available to maximise the overall energy efficiency of any building

•Simplelightvariationcanbeachieved by Titus, through circuit switching or dimming. By reducing the power consumption on demand, energy saving is achieved.

•Thecurvedbodyprofileensuresgreat rigidity and mechanical strength whilst the steel stove enamel finish provides resistance to physically and chemically aggressive environments

•Heavydutyelectronicballastsused in certain Titus Industry versions ensures long reliable operation, saving maintenance costs in difficult to access areas

Comfort: giving people satisfaction and stimulation

•Highfrequencygeareliminatesthe risks and aggravation of stroboscopic effects, which can occur in high-speed sports or where rotating machinery is present

•Intheeventofthemainssupplyfailing, it is reassuring to know that integrated emergency versions of Titus will provide the correct level of illumination to reduce confusion and aid safe evacuation

•Betterindustriallightingcanboost workers’ morale and productivity, while in the sporting arena good lighting encourages performances and crowdenjoyment

3

Leisure Centre, Boson, Sweden

Indoor Sports Applications

Indoor sports facilities are being developed or upgraded throughout the world to achieve higher quality lighting

Lighting specifications are becoming more onerous, requiring increased illuminance, control flexibility and the ability to cater for multiple sport types. The Titus Sport range has been extended to address the following application needs:

Flexibility of use Most indoor sports halls cater for a mixture of different sports and non-sporting events. As all sports have different visual requirements, it is critical to define all likely activities and levels of play.

EN12193 defines all sporting requirements based on the level of competition and lighting class (I,II or III). See table above, plus individual activity requirements on page 7.

•TitusSporthasbeendevelopedfor use with ceiling heights of 4m+

•Schemescanbeplannedtocater for all three levels of competition

•Availablein49W,54Wand 80W

Visual environment It is easy to think that getting the lighting right is a matter of achieving the right lighting level, but lighting must also create the right visual performance. The uniformity of illumination, for example, affects the perception of space and the ability to play effectively. Discomfort glare determines how uncomfortable players find the lighting. Stroboscopic effect can impact the visual perception of moving objects,andmodellingisimportant as poor control of shadowingcanmakeobjectsappear unclear and flat. Discomfort glare, stroboscopic effect and modelling can all affect the performers ability to concentrate without distraction or fatigue.

•Titusprovideshighlevelsofvisual performance through a specially designed MIRO reflector

•Optionallouvresgiveadditional glare reduction

•T16lampsprovidehigh colour rendering

•Electronicballastsofferflicker free light eliminating stroboscopic effects

Level of competition Lighting ClassI II III

International or national 3

Regional 3 3

Local 3 3 3

Training 3 3

Recreational/education 3

4

Silkeborg Sports Centre, Denmark

5

Lighting control One lighting layout may not meet all requirements, as specific sports require different lighting configurations. (eg tennis - practice = 300 lux, tournament = 750 lux)

It is often essential for the lighting system to allow groups of luminaires to be controlled, adjustingtheleveloflightaccording to the sport. Simple luminaire lamp switching or linking directly to lighting controls enables flexibility in illuminance and a lower energy demand, allowing savings to be achieved. Some installations have daylight present, and further energy savings may be made by linking the luminaires to daylight sensors.

Forspectatoreventsthereisagrowing demand to provide theatrical lighting effects that can create atmosphere and interaction between the players and spectators. Again, this calls for lighting controls:

•Titusoffersafacilityforseparate circuit switching for different light output levels

•Dimmingcontrolgearallowsdynamic lighting effects

•Compatibilitywithlightingcontrols allows precise control and energy savings to be achieved

Arrangement of luminaires Forsportssuchasbadmintonand tennis, the positioning of the luminaires outside the playing area may be necessary to avoid disability glare for players looking upwards, whilst delivering a good level of vertical illuminance to ensure visibility of any high play.

•Tituscanbetiltedupto50°via patented brackets and still provide optimal light direction

•Allowsopportunityforproductplacement outside of the players viewing sight

Impact resistance Indoor sports luminaires should be impact resistant against balls andprojectiles.Theyshouldbe designed and mounted to minimisetherisksofobjectsbecoming trapped within or behind them.

•Titus’curvedbodyprofilepreventsprojectilesbecoming‘lodged’

•Arobustlockablewireguardsafeguards the lamps (IK09)

•DIN18032.3(ballimpactproof)approved

Norresundby Swimming Pool, Aalborg Denmark

Skøjtehal Ice Rink, Arhus Denmark

6

Indoor Sports Applications

Occasionally there is a requirement for a luminaire which is designed for prolonged, reliable operation in indoor sporting applications where environmental conditions are severe. Warm humid atmospheres, perhaps carrying corrosive agents, or low ambient temperatures, such as in swimming pools and ice

rinks, are representative of the more extreme conditions encountered. Titus Industry is justthatluminaire.Itismadefromgalvanised steel finished in grey with a protective glass enclosure, sealedtoIP65(dusttight,jetproof).

For certain sports, careful consideration needs to be given to environmental conditions

7

Type of area, task or activity Class Em Ra UoAerobics (recreational) 200 20 0.50Archery (lane/target) 200/Ev 750 60 0.5/0.8Athletics (indoor) Class I 500 60 0.70

Class II 300 60 0.60Class III 200 20 0.50

Badminton Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.70

Basketball (indoor) Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Billiards Class I 750 80 0.80Class II 500 80 0.80Class III 500 80 0.80

Boccia (indoor) Class I 300 60 0.70Class II 200 60 0.70Class III 200 20 0.50

Boules (indoor) Class I 300 60 0.70Class II 200 60 0.70Class III 200 20 0.50

10 pin/9 pin bowling Lanes 200 60 0.50Pins 25m lane Ev 1000 0.80Pins 50m lane Ev 2000 0.80

Boxing Class I 2000 80 0.80Class II 1000 80 0.80Class III 500 60 0.50

Climbing Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.50

Cricket nets Class I 1500 60 0.80Class II 1000 60 0.80Class III 750 20 0.80

Curling (target/playing area) 300/200 0.70 0.70Cycling (indoor) Class I 750 60 0.70

Class II 500 60 0.70Class III 200 20 0.50

Dancing Class I 500 60 0.70Class II 300 60 0.60Class III 200 20 0.50

Darts Class I Eh 200/Ev 750 60Class II Eh 100/Ev 500 60Class III Eh 50/Ev 300 20

Fencing Class I Eh 750/Ev 500 60 0.70Class II Eh 500/Ev 300 60 0.70Class III Eh 300/Ev 200 20 0.70

Football(indoor) Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Gymnastics Class I 500 60 0.70Class II 300 60 0.60Class III 200 20 0.50

Handball(indoor) Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Type of area, task or activity Class Em Ra UoHockey(indoor) Class I 750 60 0.70

Class II 500 60 0.70Class III 300 20 0.70

Ice hockey (indoor) Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.70

Ice skating Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.70

Judo Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Kendo/Karate Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Netball (indoor) Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Petanque (indoor) Class I 300 60 0.70Class II 200 60 0.70Class III 200 20 0.50

Racketball Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.70

Roller skating Class I 500 60 0.70Class II 300 60 0.60Class III 200 20 0.50

School sports Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Shooting (lane/target) 200/Ev 750 60 0.5/0.8Snooker Class I 750 80 0.80

Class II 500 80 0.80Class III 500 80 0.80

Speed skating Class I 500 60 0.70Class II 300 60 0.60Class III 200 20 0.50

Squash Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.70

Swimming Class I 500 60 0.70Class II 300 60 0.70Class III 200 20 0.50

Table tennis Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.70

Tennis (indoor) Class I 750 60 0.70Class II 500 60 0.70Class III 300 20 0.50

Weight lifting Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

Wrestling Class I 750 60 0.70Class II 500 60 0.70Class III 200 20 0.50

This table contains lighting recommendations for a variety of sports. Lighting requirements may differ according to the level of competition of a sport, and therefore requirements are shown for different lighting classes according to EN 12193: 2007 Light and Lighting - Sports Lighting

EN 12193: 2007 Light and Lighting - Sports Lighting

20X20m

Massive potential yearly power saving of 60%! (9,145,440W)

Graph B Power ConsumptionShows the energy saving potential over a yearly period when usingdimming technology linking to day light levels to achieve 500 lux.

Graph A Lighting ContributionShows the contribution of average daylight and luminaire artificial light required to achieve 500 lux.

Size: 20m X 20m, with a ceiling height of 6m’s containing 10% sky lights by floor area. Usage: Daily from 9am to 5pm (7 days a week, 365 days a year).

Based on Titus Industry 3 X 80W TW (fixed output) and Titus Industry 3 X 80W HFD TW (dimming output).

Required task illuminance level = 500 luxActual task illuminance level = 582 luxLuminaire quantity = 20

0

25

50

75

100

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

% o

f Tot

al L

ight

ing

illum

inan

ce

Artificial Luminaire Light % Output Contribution

Average Daylight % Output Contribution*

*Based on CIE average overcast sky value

Titus Industry 3 X 80W HFD TW Yearly power consumption = 6,096,960W

Titus Industry 3 X 80W TW Yearly power consumption = 15,242,400W

0

1500

3000

4500

6000

Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Pow

er (W

)

Industrial Applications

There isn’t an employer in industry who wouldn’t like to see a reduction in accidents and running costs, whilst improving worker morale and productivity

Energy saving Substantial savings can be made by controlling the hours of use. The lighting may be on unnecessarily whilst the building, or part of it, is unoccupied, for example, a racking area that is not continuously used. Also giving flexibility and control to the occupants increases their efficiency and effectiveness.

Simple use of daylight detectors allows natural daylight to be maximised, allowing luminaires to be powered only when required resulting in further energy savings!

•TitusIndustryoffersdimming,allowing a simple variation in illuminance

•CompatibilitywithThornlighting controls, such as daylight/presence sensors. Formorecontroldetailspleaserefer to Thorn’s SensaLite brochure

A typical industrial area schemeThe example scheme shows typical energy saving potential benefits that can be achieved when linking luminaires to day light control systems.

Happily,there’soneluminairethatcanhelpdeliveralltheseobjectives– Titus Industry. It has been designed with detailed consideration to the following application issues:

8

Aiding vision Although we must never forget the importance of energy saving, a lighting system chosen on the basis of this factor alone will not necessarily provide the correct lit environment. If the installation does not aid vision, then it cannot be claimed to be energy efficient.

Illuminance on the task is the main criteria as the level of lighting can effect productivity levels, motivation and create a safer working environment for employees.

Varying visual needs require the consideration of factors such as colour rendering, glare and illuminance levels, and these should be taken into account when choosing the correct luminaire/lamp combination.

Industrial areas generally contain different height equipment (eg press machines, racking and cranes) therefore it is essential to achieve good modelling, contrast and control of shadowing in any lighting scheme. Where rotatory machinery is used, the stroboscopic effect should be eliminated to reduce the risk of any potential accidents.

•TitusIndustry’shighperformance MIRO reflectors give precise light distribution

•Availablein49W,54Wand80W

•Optionallouvreattachmentsallows greater glare control

•Electronicballastsofferflicker free light, eliminating stroboscopic effects

Concrete Factory, Betongfabrik, Ulricehamn

Maintenance Many industrial environments have impurities in the power supply due to electrical motors running, or couplers connecting/disconnecting huge loads, giving spikes and voltage fluctuations.

Over time this can impact and reduce the gear and lamp life of any luminaire. If a fitting has not been designed for prolonged operation in the areas where it will find most use, it will fail.

Frequentaccesstofittingscan be difficult and costly, so measures that ease access should be considered, along with technology that extends maintenance intervals and designs that aid easy cleaning.

•Titus Industry offers robust heavy duty electronic ballasts: Long service life up to 100,000 + hours for extended maintenance cycles - Designed to withstand voltage peaks up to 4kV for reliable operation

•Theluminaire’stiltingfacility(upto50°)andasymmetriclight distributions allow flexible mounting positions around the task area for easy maintenance access

•Glasscoverremainsfixedtothe luminaire when open

9

Concrete Factory, Betongfabrik, Ulricehamn

10

•Goodmodellingandreducedshadowing can be easily achieved using a linear light source over a single point source

•Excellentcolourtemperaturesand rendering characteristics (Ra 85+) for improved visibility and compliance to EN 12464

•Opportunitytoeasily add lighting controls to the scheme. Dimming versions allow flexible illuminance levels or energy savings to be made on demand.

•Integralemergencyversionssave installation time and money compared to installing separate task and emergency lighting

•Steplesstiltingandasymmetriclight distributions provide directional light. This offers flexibility in luminaire positioning in any scheme design where placement around obstacles or access for maintenance might be difficult and costly.

•Thelampandcontrolgearcombination offers great lumen maintenance depreciation (>90% at 16,000hrs) maximising luminaire maintenance interval periods

•Electronicgearsallowlampsto be instantly dimmed and switched on/off when linked to lighting controls, to provide an efficient easy energy saving solution

Industrial Applications

Harsh environments Many industrial spaces have extreme environmental conditions. Mechanical stress is also often present, therefore, luminaires should be designed and chosen to ensure they are suitable for the environmental conditions within the task space.

•TitusIndustryissealedtoIP65(dusttightandjetproof)

•Atoughenedglasspanelclamped to a single pour rubber gasket, by long toggles, ensures consistent gasket pressure and reliability

•ImpactresistancetoIK08confirms its suitability for challenging applications

•Robustfabricatedsteelbodyensures mechanical strength

Titus Range Advantages Over High Pressure Discharge Luminaires

When comparing in a scheme, traditional single point source discharge solutions such as high/low bays or floodlights, the Titus range offers many benefits including:

Heathrow Airport Terminal 5, UK© www.baa.com/photolibrary

11

12

A dedicated sports hall luminaire matching the high expectations for rigid mechanical construction and superb lighting performance

Titus Sport

Titus Sport has been developed for use in all sports, athletics and recreational halls. •Uniquecurvedhousingpreventsprojectilesfromremainingontop of the fitting

•Suppliedanddeliveredwithprotective lockable wire guard

•Separatecircuitswitching on 3 and 4 lamp versions (2+2 or 1+2)

•Patentedmountingbracketallowssteplesstiltingupto50°without rotational torque

•Easyinstallationandmaintenance with patented built-injunctionbox

•Dimmingversionsarecompatible with lighting controls

•Optionallouvresforadditionalglare control (twin lamps only)

•DIN18032.3(ballimpactproof)approved

Lamps49W-80WT16(FDH) linear fluorescent. Cap: G5

Materials/FinishBody: white powder painted galvanised steel Wire guard: galvanised steel Reflector: high quality MIRO aluminium. Halogenfreeinternalwiring.

Installation/MountingSurface mounted or mounted on catenary pipe or catenary wire. Mounting brackets included which allow tilting up to 50° even when wire suspended. The centre of gravity is positioned directly below thefasteningpoint.Forcatenarysuspension either wire fastenings or pipe clamps should be ordered. The wire guard and optional louvres are hinged for ease of maintenance.

Electrical connection Two versions of Titus Sport are available:

1. Central wiring box version with patentedbuilt-injunctionbox(minimising installation time) has side access hatch to allow electrical termination without opening the fitting.

Two 3 x 2 x 2.5mm² terminal blocks allow wiring through end-caps or top of fitting. Grommets supplied, accepting 10 to 14mm cable.

2. Through-wiring version has 5 x 2 x 2.5mm² terminal blocks at each end.

Wire guard hinges for maintenance

StandardsDesigned and manufactured to comply with EN 60598EN 605982.22Tested and approved to DIN18032-3, (36 handball shots at impact speed exceeding 16.5m/s) IP23 (IP21 when tilted up to 50˚)IK09

SpecificationTo specify state: Sports hall luminaire for 49W, 54W or 80W T16 (T5) lamps, for surface or suspended mounting with brackets included which allow tilting up to 50° without rotational torque. To comply with DIN 18032.3. As Thorn Titus Sport.

Side access ‘hatch’ for electrical connection Optional top cable entry

13

TW-Throughwiring,E3TX-3houremergencySelfTestAddressable,PSB-Flatsatincrossvanes,DSB-Paraboliccrossvanesallsatinfinish,HFD-HighFrequencyDimmable*Only suitable for two lamp versions

NB:**AmalgamLampUsageWe recommend the use of amalgam lamps in applications where non dimming is required in Titus Sport 4x80W versions (96205439 & 96205440) only to allow a higher luminaire efficiency to be achieved.

We do not recommend the use of amalgam lamps in applications where very fast start up, dimming or emergency lighting is essential.

Ordering Guide T16 lamps to be ordered separately.

Description Ilcos Code Socket Wt (kg) SAP Code

High FrequencyTITUSSPORT2X49W FDH G5 7.80 96008788TITUSSPORT2X54W FDH G5 6.80 96008789TITUSSPORT3X49W FDH G5 8.10 96008790TITUSSPORT3X54W FDH G5 7.10 96008791TITUSSPORT3X80W FDH G5 8.10 96205433TITUSSPORT4X49W FDH G5 8.20 96008792TITUSSPORT4X54W FDH G5 7.20 96008793TITUSSPORT4X80W FDH G5 9.10 96205439**

High Frequency Dimmable

TITUSSPORT3X49WHFD FDH G5 8.10 96205423TITUSSPORT3X80WHFD FDH G5 8.20 96205435TITUSSPORT4X49WHFD FDH G5 9.20 96205425TITUSSPORT4X54WHFD FDH G5 7.10 96205431TITUSSPORT4X80WHFD FDH G5 9.20 96205441

High Frequency Emergency SelfTest AddressableTITUSSPORT2X49WE3TX FDH G5 9.50 96206065TITUSSPORT3X49WE3TX FDH G5 10.00 96206066TITUSSPORT3X80WE3TX FDH G5 9.80 96206067TITUSSPORT4X49WE3TX FDH G5 10.00 96206068TITUSSPORT4X54WE3TX FDH G5 8.00 96206069TITUSSPORT4X80WE3TX FDH G5 10.00 96206070

High Frequency Through WireTITUSSPORT2X49WTW FDH G5 7.90 96008794TITUSSPORT2X54WTW FDH G5 6.90 96008796TITUSSPORT3X49WTW FDH G5 8.20 96008797TITUSSPORT3X54WTW FDH G5 7.20 96008799

TITUSSPORT3X80WTW FDH G5 8.20 96205434

TITUSSPORT4X49WTW FDH G5 8.30 96010201

TITUSSPORT4X54WTW FDH G5 7.30 96010203

TITUSSPORT4X80WTW FDH G5 9.20 96205440**

High Frequency Dimmable Through WireTITUSSPORT3X49WHFDTW FDH G5 8.10 96205424TITUSSPORT3X80WHFDTW FDH G5 8.40 96205436TITUSSPORT4X49WHFDTW FDH G5 9.40 96205426TITUSSPORT4X54WHFDTW FDH G5 7.20 96205432TITUSSPORT4X80WHFDTW FDH G5 9.40 96205442

Attachments*TITUSLOUVRE54WPSB 0.85 96010222TITUSLOUVRE49WPSB 0.94 96010223TITUSLOUVRE54WDSB 0.85 96010224TITUSLOUVREB49WDSB 0.94 96010225TITUSLOUVREB54WDSB30DEGREES 0.85 96010226TITUSLOUVREB49WDSB30DEGREES 0.94 96010227

AccessoriesPIPECLAMPSFASTENINGS-PAIR 0.40 96010221WIRESUSPENSIONFASTENINGS-PAIR 0.07 96010220

E3TX emergency versions offer SelfTest and Addressable Test functionality in a single fitting. E3TX luminaires operate as SelfTest when stand alone. A diagnostic processor automatically performs the mandatory function and duration tests, using a bi-colour LED indicator to show the results.

These emergency fittings become addressable when connected to Thorn’s ExplorerProjectorExplorerVisionsystem.This links every luminaire to an intelligent local controller that automatically conducts all the necessary tests and stores the full results in one central location.

200

300

100

90° 90°

cd/1000 lm

60° 60°

30°30°

Titus Sport Lamp: T16 3 X 80WLOR: 79%

FC=Fixingcentres

1534 / 49/80W

FC1598/49/80W

1620 / 49/80W

1234 / 54W

231

FC1298/54W

1320 / 54W

157 135

Titus SportLamp: T16 2 X 49WLOR: 78%

240

360

120

90° 90°

cd/1000 lm

60° 60°

30°30°

Titus Sport with PSB louvreLamp: T16 2 X 49WLOR: 62%

240

360

120

90° 90°

cd/1000 lm

60° 60°

30°30°

14

Lamps49-80WT16(FDH) linear fluorescent. Cap: G5

Materials/FinishBody: matt grey powder painted galvanised steel Reflector: high quality MIRO aluminium Protective glass: 4mm toughened glass with EPDM gasket. Halogenfreeinternalwiring.

Installation/MountingSurface mounted or mounted on catenary wire. Mounting brackets included which allow tilting up to 50° without rotational torque. The centre of gravity is positioned directly below the fastening point.Forcatenarysuspensionfastening accessories should be ordered. Electrical connection: through-wiring version with 5 X 2 X 2.5mm² terminal blocks at each end. Grommets supplied, accepting 10 to 14mm cable.

StandardsDesigned and manufactured to comply with EN 60598 EN 605982.22 IP65IK08

SpecificationTo specify state: Dedicated IP65 industrial luminaire for T16 (T5) linear fluorescent lamps, for surface or suspended mounting with brackets which allow tilting up to 50° degrees without rotational torque. As Thorn Titus Industry.

A range designed to meet the higher demands of industrial applications in terms of protection and mechanical construction

Titus Industry

The luminaire is built to withstand aggressive environments and has a high level of corrosion protection as standard - for example when used in car cleaning facilities where detergents can easily destroy conventional plastic luminaires.

•Fourlongtoggles(570mmin length) maintain gasket pressure to ensure a consistent gasket seal and IP65 reassurance

•Patentedmountingbracketallowssteplesstiltingupto50°without rotational torque

•Asymmetriclightdistributionsavailable

•Optionallouvresavailable for additional glare control (twin lamp only)

•Dimmableversionsavailable

•Heavydutyballastversionsforreliable long life solutions

Optional louvres

EPDM gasket gives IP65 seal

Long toggles to maintain gasket pressure

15

Ordering Guide T16 Lamps to be ordered separately.

Description Ilcos Code Socket Wt (kg) SAP Code

High Frequency Through WireTITUSINDUSTRY1X49WTW FDH G5 11.60 96010204TITUSINDUSTRY1X54WTW FDH G5 10.40 96010205TITUSINDUSTRY2X49WTW FDH G5 11.90 96010208TITUSINDUSTRY2X54WTW FDH G5 10.70 96010209TITUSINDUSTRY3X49WTW FDH G5 12.20 96010212TITUSINDUSTRY3X54WTW FDH G5 10.80 96010213TITUSINDUSTRY3X80WTW FDH G5 12.20 96205454**TITUSINDUSTRY4X49WTW FDH G5 12.30 96010214TITUSINDUSTRY4X54WTW FDH G5 10.90 96010215

High Frequency Dimmable Through WireTITUSINDUSTRY3X80WHFDTW FDH G5 12.40 96205456TITUSINDUSTRY4X49WHFDTW FDH G5 13.50 96205450TITUSINDUSTRY4X54WHFDTW FDH G5 10.90 96205453

High Frequency Through Wire Emergency SelfTest AddressableTITUSINDUSTRY2X49WTWE3TX FDH G5 12.50 96206061TITUSINDUSTRY3X49WTWE3TXR FDH G5 10.00 96206063TITUSINDUSTRY4X49WTWE3TXR FDH G5 10.10 96206064

High Frequency Through Wire AsymmetricTITUSINDUSTRY1X49WTWAS FDH G5 11.60 96010206TITUSINDUSTRY1X54WTWAS FDH G5 10.40 96010207TITUSINDUSTRY2X49WTWAS FDH G5 11.90 96010210TITUSINDUSTRY2X54WTWAS FDH G5 10.70 96010211

Industry High Frequency Ballast Through Wire

TITUSINDUSTRY3X80WIHFTW FDH G5 12.40 96205455**TITUSINDUSTRY4X49WIHFTW FDH G5 13.50 96205449TITUSINDUSTRY4X54WIHFTW FDH G5 10.90 96205452TITUSINDUSTRY4X80WIHFTW FDH G5 13.50 96205458**

Attachments*TITUSLOUVRE49WPSB 0.94 96010223TITUSLOUVRE54WPSB 0.85 96010222TITUSLOUVREB49WDSB 0.94 96010225TITUSLOUVRE54WDSB 0.85 96010224TITUSLOUVREB49WDSB30DEGREES 0.94 96010227TITUSLOUVREB54WDSB30DEGREES 0.85 96010226

AccessoriesWIRESUSPENSIONCLIPKITTYPE2 0.07 96010220

TW-Throughwiring,HFD-HighFrequencyDimmable,AS-Asymmetric,R-Remoteexternalbox, E3TX-3houremergencySelfTestAddressable,IHF-IndustryheavydutyHighFrequencyballast, PSB-Flatsatincrossvanes,DSB-Parabolicvanesallsatinfinish*Only suitable for two lamp versions

NB**AmalgamLampUsageWe recommend the use of amalgam lamps in applications where non dimming is required in Titus Industry 80W versions (96205454, 96205455 & 96205458) only to allow a higher luminaire efficiency to be achieved.

We do not recommend the use of amalgam lamps in applications where very fast start up, dimming or emergency (especially dangerous work areas) is essential.

200

300

100

90° 90°

cd/1000 lm

60° 60°

30°30°

Titus Industry Lamp: T16 2 X 49W TWLOR: 89%

E3TX emergency versions offer SelfTest and Addressable Test functionality in a single fitting. E3TX luminaires operate as SelfTest when stand alone. A diagnostic processor automatically performs the mandatory function and duration tests, using a bi-colour LED indicator to show the results.

These emergency fittings become addressable when connected to Thorn’s ExplorerProjectorExplorerVisionsystem.This links every luminaire to an intelligent local controller that automatically conducts all the necessary tests and stores the full results in one central location.

FC=Fixingcentres

1620 / 49/80W

FC1598/49/80W

1534 / 49/80W

1234 / 54W

FC1298/54W

1320 / 54W

248

165 135

Titus Industry with PSB louvreLamp: T16 2 X 49W TWLOR: 71%

240

360

120

90° 90°

cd/1000 lm

60° 60°

30°30°

Titus Industry with DSB 30° louvreLamp: T16 2 X 49W TWLOR: 60%

240

360

120

90° 90°

cd/1000 lm

60° 60°

30°30°

Lighting people and places

AustraliaThorn Lighting Pty Limited 43 Newton Road, Wetherill Park NSW 2164Tel: (02) 8786 6000Fax: (02) 9612 2700E-mail: [email protected]: www.thornlighting.com.au

AustriaThorn Licht GmbH Donau-City-Straße 1, 1220 Wien, AustriaTel: (43) 1 202 66 11Fax: (43) 1 202 66 11 12E-mail: [email protected]: www.thornlighting.at

ChinaThorn Lighting (Guangzhou) Operations Ltd, No.12 Lian Yun Road, Eastern Section, GETDD, Guangzhou 510530, ChinaTel: (86) 20 3228 2706Fax: (86) 20 3228 1777E-mail: [email protected]

Thorn Lighting (Tianjin) Co. Ltd 332 Hongqi Road, Tianjin 300190, ChinaTel: (86) 22 8369 2303Fax: (86) 22 8369 2302E-mail: [email protected]

Czech RepublicThorn Lighting CS spol. s.r.o., Na Březince 6/930, 150 00 Praha 5Czech RepublicTel: (420) 224 315 252Fax: (420) 233 326 313E-mail: [email protected]: www.thornlighting.cz

DenmarkThorn Lighting A/SKanonbådsvej 12B, 1437 København K, DenmarkTel: (45) 7696 3600Fax: (45) 3264 0499E-mail: [email protected]: www.thornlighting.dk

FranceThorn Europhane SA 156 Boulevard Haussmann, Cedex 08, Paris 75379, FranceTel: (33) 1 49 53 6262Fax: (33) 1 49 53 6240Website: www.thornlighting.fr

Hong KongThorn Lighting (Hong Kong) LimitedUnit 4301, Level 43, Tower 1, Metroplaza,223 Hing Fong Road, Kwai Chung, N.T., Hong KongTel: (852) 2578 4303Fax: (852) 2887 0247E-mail: [email protected]

IndiaThorn Lighting India Pvt. Ltd.501, 5th Floor, Tanishka,Opp. Gundecha Industrial EstateAkurli Road, Kandivali (E), Mumbai – 400 101Tel: (91) 22285 41056Fax: (91) 22285 1120E-mail: [email protected]: www.thornlighting.com

IrelandThorn Lighting (Ireland) Limited 320 Harold’s Cross Road, Dublin 6W, IrelandTel: (353) 1 4922 877Fax: (353) 1 4922 724E-mail: [email protected]: www.thornlighting.co.uk

ItalyThorn Europhane Spa Via G Di Vittorio, 2, Cadriano di Granarolo, Bologna 40057, ItalyTel: (39) 051 763391Fax: (39) 051 763088E-mail: [email protected]: www.thornlighting.it

New ZealandThorn Lighting (NZ) Ltd 399 Rosebank Road, Avondale, Auckland 1026 PO Box 71134, Rosebank, Auckland 1348Tel: (64) 9 828 7155Fax: (64) 9 828 7591E-mail: [email protected] Website: www.thornlighting.co.nz

NorwayThorn Lighting ASStrømsveien 344, 1081 Oslo, NorwayTel: (47) 22 82 07 00Fax: (47) 22 82 07 01E-mail: [email protected]: www.thornlighting.no

PolandThorn Lighting Polska Sp.z.o.o., Ul. Gazowa 26A, Wrocław 50-513, PolandTel: (48) 71 7833 740Fax: (48) 71 3366 029E-mail: [email protected] Website: www.thornlighting.pl

RussiaThorn Lighting Novoslobodskaya Str., 21, office 406 Business Center “Novoslobodskaya 21”, Moscow 127030, RussiaTel: (7) 495 981 35 41Fax: (7) 495 981 35 42E-mail: [email protected]: www.thornlighting.ru

Thorn Lighting is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. The right is reserved to change specifications without prior notification or public announcement. All goods supplied by the company are supplied subject to the company’s General Conditions of Sale, a copy of which is available on request. All measurements are in millimetres and weights in kilograms unless otherwise stated.

Publication No: 440 (INT) Publication Date: 03/09

Thorn Lighting Main OfficesSingaporeThorn Lighting (Singapore) Pte Ltd5 Kaki Bukit Crescent, 04-02 Koyotech Building, 416238 SingaporeTel: (65) 6844 5800Fax: (65) 6745 7707E-mail: [email protected]

SwedenThorn Lighting ABIndustrigatan, Box 305, SE-261 23 Landskrona, SwedenTel: (46) 418 520 00Fax: (46) 418 265 74E-mail: [email protected]: www.thornlighting.se

United Arab EmiratesThorn Lighting Ltd Dubai Al Shoala Building, Office 301, Block E, Airport road, P.O. Box 1200, Deira, Dubai, UAETel: (971) 4 2940181Fax: (971) 4 2948838E-mail: [email protected]: www.thornlighting.com

Thorn Gulf LLC Al Shoala Building, Office 301/2, Block E, Airport road, P.O. Box 22672, Deira, Dubai, UAETel: (971) 4 2948938Fax: (971) 4 2948838E-mail: [email protected]: www.thornlighting.com

United KingdomThorn Lighting Limited Silver Screens, Elstree Way, Borehamwood, Hertfordshire, WD6 1FE, UKTel: (44) 20 8732 9800Fax: (44) 20 8732 9801E-mail: [email protected]

Thorn Olympics Sports Lighting TeamTel: 07785 251 438E-mail: [email protected]: www.thornlighting.co.uk

International SalesThorn Lighting Limited Silver Screens, Elstree Way, Borehamwood, Hertfordshire, WD6 1FE, UKTel: (44) 20 8732 1915Fax: (44) 20 8732 1911E-mail: [email protected]: www.thornlighting.com

www.thornlighting.com