• What is Title 24?• What changes are going into effect?• How will customers be able to meet

requirements?• Prescriptive method• Performance method

• How does Title 24 vary from Energy Star?• How will Simonton meet Title 24 requirements• Coastal Zone variances

Title 24 Agenda

Page 4: Title 24 for Simonton DSM's

Title 24 is the California Energy Commission’s (CEC) Energy Standards for Residential and Non-residential

buildings. For windows, requirements include;

• U-Factor performance minimums• SHGC performance minimums• Air Infiltration maximums• Is 100% independent from Energy Star

What is Title 24?

Page 5: Title 24 for Simonton DSM's

What is Title 24?

To be approved for building permits in the state of California, projects must meet or exceed Title 24

building code requirements.

• Title 24 is established as a minimum performance threshold

• Jurisdictions can supersede the code/make it more strict

Page 6: Title 24 for Simonton DSM's

6

Effective July 1, 2014

Requirements

For all of CA, except Coastal Zones 1, 3

and 5*

U-Factor Air

Cfm/sf SHGC*

2014 Code Residential Prescriptive

0.32 ≤.30 0.25

Current Title 24 Prescriptive

0.40 0.40

Page 7: Title 24 for Simonton DSM's

How to meet Title 24 requirements

– Prescriptive Method• Most common• Easiest to determine: .32 U-factor, ≤.30 cfm/sf air

infiltration, and .25 SHGC (Coastal SHGC requirements for Zones 1, 3 and 5 will differ)

– Performance Method• Less common• Several factors involved

All CA homeowners replacing windows will be required to meet Title 24 requirements

following one of two methods:

Page 8: Title 24 for Simonton DSM's

How to meet Title 24 requirements

• Required to follow code exactly, no exceptions

• Same U-factor and air infiltration requirements for all 16 California Energy Zones (Zones 1, 3 and 5 SHGC requirements differ)

• Simple to follow

• Saves time when pulling a permit

• Can be used for both residential new construction and replacement windows

Prescriptive Method

Page 9: Title 24 for Simonton DSM's

Performance Method Calculation

• The performance of the home as a whole is taken into consideration

• Requires approximately 2 weeks to receive the needed report, can delay permits

• ‘Title 24 Consultants’ utilize software such as “Alternative Calculation Method” to find whether or not the home meets requirements and provide wiggle room for products not meeting the prescriptive method

• Average costs of testing is $200-300

How to meet Title 24 requirements

Page 10: Title 24 for Simonton DSM's

10

Page 11: Title 24 for Simonton DSM's

11

Energy Star® vs. Title 24

South Central

South Central

North Central

Energy Star Climate Zones

Page 12: Title 24 for Simonton DSM's

What does this mean for Simonton & You?

Page 13: Title 24 for Simonton DSM's

13

Simonton & Title 24

Simonton will make it simple to meet the prescriptive Title 24 requirements by offering the “Title 24 Glass

Package,” available in EPOPS.

Page 14: Title 24 for Simonton DSM's

14

Simonton & Title 24Prescriptive:U Value ≤ .32SHGC ≤ .25

Product Series Style (w/o grids) Glass Gas Spacer USHGC no

grids/grids MeetsBase - ProSolar Argon Intercept 0.30 0.31 NoT24 - ProSolar

Shade Argon Intercept 0.29 0.22/0.20 YesBase - ProSolar Argon Intercept 0.27 0.32 NoT24 - ProSolar

Shade Argon Intercept 0.26 0.23/0.21 YesBase - ProSolar Argon Intercept 0.29 0.30 NoT24 - ProSolar

Shade Argon Intercept 0.29 0.22/0.20 YesBase - ProSolar Argon Intercept 0.27 0.22 YesT24 - ProSolar

Shade Argon Intercept 0.27 0.11/0.16 Yes

SH 3050

D'Max

PW 4040

SL 5030

CS 3040

Page 15: Title 24 for Simonton DSM's

15

Simonton & Title 24Prescriptive:U Value ≤ .32SHGC ≤ .25

Product Series Style (w/o grids) Glass Gas Spacer USHGC no

grids/grids MeetsBase - ProSolar Argon Intercept 0.29 0.29 NoT24 - ProSolar

Shade Argon Intercept 0.29 0.21/0.19 YesBase - ProSolar Argon Intercept 0.30 0.28 NoT24 - ProSolar

Shade Argon Intercept 0.29 0.20/0.18 YesBase - ProSolar Argon Intercept 0.30 0.29 NoT24 - ProSolar

Shade Argon Intercept 0.29 0.20/0.18 YesBase - ProSolar Argon Intercept 0.28 0.30 NoT24 - ProSolar

Shade Argon Intercept 0.28 0.22/0.19 Yes

Madeira

SL 5030

DH 3050

SH 3050

PW 4040

Page 16: Title 24 for Simonton DSM's

16

Simonton & Title 24Prescriptive:U Value ≤ .32SHGC ≤ .25

Product Series Style (w/o grids) Glass Gas Spacer USHGC no

grids/grids MeetsProSolar (Std) Argon Intercept 0.32 0.25 + NoT24 - ProSolar

Shade Argon Intercept 0.31 0.18/0.16 YesProSolar (Std) Argon Intercept 0.32 0.25 + NoT24 - ProSolar

Shade Argon Intercept 0.29 0.21/0.19 YesLumera 2, 3, 4 -Lite ProSolar (Std) Argon Intercept 0.32 0.18/0.15 Yes

French Rail PD

Contemporary PD

2, 3, 4 -Lite

2, 3, 4 -Lite

Page 17: Title 24 for Simonton DSM's

17

Simonton & Title 24Prescriptive:U Value ≤ .32SHGC ≤ .25

Product Series Style (w/o grids) Glass Gas Spacer USHGC no

grids/grids MeetsClear Air Intercept 0.48 0.63 NO

ProSolar Argon Intercept 0.31 0.30 NOProSolar Shade Argon Supercept 0.31 0.22/0.19 Yes

Clear Air Intercept 0.48 0.63 NOProSolar Argon Intercept 0.30 0.30 NO

ProSolar Shade Argon Supercept 0.30 0.22/0.19 YesClear Air Intercept 0.47 0.70 NO

ProSolar Argon Intercept 0.27 0.33 NOProSolar Shade Argon Supercept 0.28 0.24/0.22 Yes

Clear Air Intercept 0.48 0.63 NOProSolar Argon Intercept 0.31 0.30 NO

ProSolar Shade Argon Supercept 0.29 0.24/0.22 YesClear Air Intercept 0.48 0.63 NO

ProSolar Argon Intercept 0.30 0.30 NOProSolar Shade Argon Supercept 0.29 0.22/0.19 Yes

SH-PC-SH 7050

Verona

PC over SL 5050

SL 5030

SH 3050

PW 4040

Page 18: Title 24 for Simonton DSM's

18

Simonton Windows, Inc. has made every effort to provide products which will help our customers meet the code requirements. In order to ensure that your project will meet all applicable codes, please consult your local design professional or code enforcement

official.

Page 19: Title 24 for Simonton DSM's

19

Title 24 Coastal variations

• U-Factor requirements are the same for all of CA

• There are NO SHGC requirements for Coastal regions 1, 3 and 5

Page 20: Title 24 for Simonton DSM's

20

Summary• Simonton currently has glass packages which will comply

with Title 24 requirements for seamless transition• Homeowners replacing windows will have to meet Title 24

requirements via Prescriptive or Performance methods• Prescriptive requirements are ≤.32 U-factor, .30 cfm/sf air

infiltration and ≤.25 SHGC for all areas other than Coastal regions 1, 3 and 5

• Coastal requirements for zones 1, 3 and 5 have no SHCG Title 24 min/max

• Utilize a “Title 24 Consultant” if using the Performance Method to ensure compliance

• When in doubt, contact your Simonton Representative