thermal power plant, yamunanagar
DESCRIPTION
slides in thermal power plantTRANSCRIPT
TRAINING SEMINAR
Training carried at:
DEEN BANDHU CHHOTU THERMAL POWER PLANT
Yamuna Nagar – 135001
Submitted To:-
HPGCL at a Glance
Haryana is one of the forerunners to initiate reforms in its power sector in 1997. Pursuant to these reforms the State Electricity Board was unbundled and reorganised on August 14,1998. HPGCL was incorporated as a company on 17th March, 1997 and was given the responsibility of operating and maintaining State’s own generation projects. Various projects are as follows:
1.Deen bandhu chhotu ram thermal power plant , yamunanagar
2.Rajiv gandhi thermal power plant , hisar
3.Panipat thermal power plant , panipat
4.Wyc hydel power plant , yamunanagar
DEEN BANDHU CHHOTU RAM THERMAL POWER PLANT
YAMUNANAGAR
INTRODUCTION
.
Installed Capacity 2 X 300 MWAvailable Land 1107 acresLocation YamunanagarEPC Contractor M/s Reliance Energy Ltd, NoidaEPC Cost Rs 2097 crore ( Total estimated cost Rs.2400
crore)Administrative approval 22.07.2002
Coal Sources Central Coal Fields
Revised Zero date of Project 20.08.2005
Synchronization 300 MW Unit – 1 : 13.11.2007
300 MW Unit – 2 : 29.03.2008Trial Operation Completed 300 MW Unit – 1 : 14.04.2008
300 MW Unit – 2 : 24.06.2008
TRAINING SECTION
Turbines & Generators -2
Turbine & its DetailsSteam Turbine: Basically we use steam turbine to convert
the pressure energy into mechanical energy .
Type: Stationary Steam Reaction turbine , with HP& IP ,LP double flow
Specifications:
Calculated Load : 300MWMain Steam Temp. : 538 CMain steam pressure : 16.7 MpaReheat steam Temp. : 538 CSpeed : 3000 rpmFeed water temp : 275.8 C
Steam flow : 926.61 T/hr
WORKING PRINCIPLE OF TURBINE
RANKINE CYCLE
SCHEMATIC DIAGRAM
OF
POWER GENERATING
CYCLE
Generator & exciter
Type : two pole cylindrical rotor type synchronous machine coupled with steam turbine
Specifications (GENERATOR):
Rated output : 300 MWRated current : 10189 APower factor : 0.85 lagging Speed : 3000 rpmFrequency : 50 HZPhase : 3 PhaseExcitation : brushless
Chimney
Height of chimney : 290 mAmount of concrete used : 44000
tonnes
COOLING TOWER
Def: A cooling tower extracts heat from water by evaporation
Type : Natural draught cooling tower
Height : 130 m
BOILER FEED PUMP
Def: A BFP (boiler feed pump ) is a device which is used to feed the
water to the boiler
It is the largest water pump I the thermal power plant It consumes about 4% of the total of electricity produce in plant
Any QUERIES ?