Test Sieve Shakers,Test Sieves

and Laboratory Equipment

HAVER & BOECKER

Page 2: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

2

HAVER Test Sieves

... with Woven Wire ClothTest Sieves are supplied with wovenwire cloth with aperture widths from20 µm to 125 mm.

HAVER Test sieves excell in- a perfect tension even after

intensive use,- a long service life,- a smooth frame surface avoiding

cross-contamination.

... withPerforatedMetal PlatesSquare hole plates canbe supplied in holewidths from 4 mm to125 mm. They haveproved especiallyefficient in the rangefrom 16 mm hole widthupwards.

Test sieves with squarehole plates are mainlyused for sieving concreteaggregate materials, roadconstruction stones, natural sand, gravel,brush a.o.

... with Electroformed SheetsTest sieves with electroformed sheets are mainly used withhole widths from 5 mm to 100 µm.

They are standardized up to 500 µm hole width. They areextraordinarily precise, though mechanically very sensitive.

These electroformed nickel-foils have round or square holeswidth wide bridges.

HAVER Test Sieves are fabricated according to the valid standards: ISO 565, DIN ISO 3310, ASTM E 11, BS 410,AFNOR, NEN 2560, ISO 5223 etc. Our “International Test Sieve Comparison Table 2003” (see pages 14 + 15) gives ageneral idea.

HAVER Test Sieves are supplied with woven wire cloth, perforated metal plates or electroformed sheets.

Page 3: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

3

Certification and Re- Certification of Test SievesDIN EN ISO 9000 ff

Measuring instruments, includingtest sieves, have to be serviced,tested and labelled at regularintervals. HAVER & BOECKERoffers the opportunity to check testsieves by a video-analysis-systemat our works laboratory. As a special Service we can checkyour test sieves on-site.

There are two types of tests thatlead to a) a certification or b) to a calibration. Certification and calibration differ in the achiechedreliability levels of test results. The number of measured aperturesizes for a calibration is three times higher than for a certification.

Test results are statistically interpreted and documented in a certificate of compliance with the standard according to DIN EN 10 204.

HAVER Grid Sieves with parallel barsaccording to DIN EN 933-3

Grid sieves are used for the deter-mination of particle shapeflakinessindex of aggregate particles.

HAVER Grid Sieves are made of an anodized aluminium frame 300 x 300 mm and stainless steel rod bars.

Slot widths are offered from 2.5 mm to 40 mm, according to DIN EN 933-3.

Page 4: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

4

HAVER Test Sieves

Test Sieve with beaded frame,standard execution with full height.

Test Sieve – Special Execution– NEW GENERATION –for Alpine®-Air Jet Sieve 200 LS-N and 200 LS-AC

Test Sieve – Special Execution– OLD GENERATION –for Alpine®-Air Jet Sieve 200 LS

Stainless Steel: Diameter D 203 =̂ 8” mm

Effective height H 28 mm

Stainless Steel or Brass: Diameter D 200 mm

Effective height H 25 mm

Test Sieve with beaded frame,half height.

Brass: Durchmesser D 200 203 =̂ 8” mm

Effective height H 25 25 mm

Brass (mm): D 200 203 =̂ 8” 300 305 =̂ 12” 400 mm

H 50 50 60 50/65 65 mm

Stainless Steel: D 100 150 200 203 =̂ 8” 300 350 400 mm

H 45 50 50 50 60 60 65 mm

HAVER test sieves excell in accuracy and stability. The optimumtension of the sieve bottom guaranties a long service life.

Sieve bottoms (woven wire cloth or screens, perforated metal plates or electroformed sheets) are fixed to the tension ring by soldering,welding or using adhesives. The tension ring is pressed into the frameand sticked to it. Sieve bottoms made from woven wire cloth with 20 µm to 45 µm aperture width are usually fixed with their downsideto the tension ring. The careful fabrication guaranties a good service life with perfectoperation.

To meet the high demands, HAVER & BOECKER carries out regularreceipt and production controlls.Each test sieve gets a certified compliance with the order 2.1according to DIN EN 10204 without extra charge.

Upon request and with extra charge an inspection certificate “B”according to EN 10204 3.1 B can be provided, too. The test recordrepresents the measuring results of the distribution of apertures intabular and graphic form.

Stainless Steel: Diameter D 200 203 =̂ 8” 300 mm

Effective height H 25 25 30 mm

H

D

Page 5: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

5

Test Sievewith flat frame, especially for ultra-fineparticle-separation.Sieve bottom permanently soldered.Stainless Steel: Diameter D 76.2 =̂ 3” mm

Effective height H 22 mm

Test sieve with beechwood framemade from seasoned beechwood.

Test Sieve with cast aluminium framewith interchangeable screens.Destined for HAVER Test Sieve ShakersEML 400 and UWL 400.Diameter D 315 400 mm

Effective height H 62 65 mmNot suitable for wet sieving.

Dimensions L x W 300 x 300 500 x 500 mm

Effective height H 80 80 mmNot suitable for wet sieving.

Intermediate ringSieve frame without base.

Sieve coverwith or without knob.

Sieve panto receive the sieved material.

Intermediate panSieve frame with solid base.

Sieve pan with outlet

Auxiliary Parts for Test Sieves

Page 6: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

6

Test Sieve Shakers and Laboratory EquipmentTest Sieve Shakers are used to separate sieveable products into single fractions. Reproducible test sieve results can be achieved in the shortest possible time. Hand sieving, which is the basis of the total separation technique, can beaccurately replicated.

HAVER Test Sieve Shakers produce a three-dimensional sieving action. The material is distributed over the whole sieving surface. For difficult products, sudden interruption of the sieving action using intermittent drives intensifies the sieving and in many cases reduces the sieving period.

HAVER Test Sieve Shakers have no rotating parts, are extremely durable, maintenance free, very adaptable and have a low noise level. Due to the use of a special spring system and cast iron parts, the construction is heavy and sturdy.This avoids unwanted vibrations being transmitted to the stationary parts of the sieve shaker and its stand.

HAVER- and TYLER®-Test Sieve Shakers

EML200

digital

Diameterin mm

Dimensionin mm

Three-dimensionalsieving action

Two-dimensionalsieving action

Self readjusting amplitude;G-Control Constant Acceleration /Rotation

––

Max. amplitude apx./mm(with maximum load)Intermittend operationControl programmableControl with storingfunctionTime switch, minutesContinuous operationAll electronic controlDigit display for allfunctions

Max. weight of sieving materialin kg (with full load)Dry sievingWet sievingExplosion-proofWeight, apx. kg (without test sieves)

Test SieveShaker:

Characteristics

App

lica

ble

Tes

t S

ieve

s

EML200

digitalplus

EML300

digitalplus

EML450

digitalplus

UWL400

Ro-Tap8”

RX-29

Ro-Tap12”

RX-30

Ro-Tap IIRX-94

Tyler8”

RX-86

Tyler12”RX-812

76 (3”)100150200203 (8”)250300305 (12”)315350400450 (18”)300 x 300500 x 500

• • • • • •• •• •• • • • • • • • • •• • • • • • • • • •

• •• • • • •• • • • •

• •• •• ••

••

• • • • • • • •

• •

• • •

• • • •• • • • • • • • • •

• • •

• • • •• • • •• • • • • • • • • •

• • • • • • • • • •• • • • • • • •

– –

– – – – – – – –

– –

2,2 3 2 2

– –

0-59 0-99 0-99 0-99 0-599 0-99 0-99 0-99 0-99 0-99––

3 3 6 15 20

– –– – – –32 34 38 100 190 82 86 100 25 25

Page 7: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

7

Test Sieve Shaker HAVER EML 200 digital plus Twith self-readjusting amplitude; G-Control

– For test sieve diameters: 3” (76 mm), 100 mm, 150 mm, 200 mm, 8” (203 mm)

– Programmable, storing functions– Three-dimensional sieving action– All electronic control– Digital display for all functions– Max. weight of full sieve tower: 3 kg

TECHNICAL DATA:Operating voltage: 230 V, 50 or 60 Hz,

110 V, 50 or 60 HzAmplitude: self-readjusting, max.

apx. 3 mmControl: programmableWeight: apx. 34 kg

The EML 200 standard model can accom-modate up to 15 half-height test sieves with200 mm (8", 203 mm) diameter.Sound absorbing cupboard optional.

HAVER EML 200 digital plus Nfor wet screening with separate control gear

This test sieve shaker is also available withoutself-readjusting amplitude in the models HAVER EML 200 digital T and N.

Page 8: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

– For test sieve diameters:200 mm, 8" (203 mm), 250 mm, 300 mm, 305 mm

– Programmable, storing functions– Three-dimensional sieving action– All electronic control– Digital display for all functions– Max. weight of full sieve tower: 6 kg

TECHNICAL DATA:Operation voltage: 230 V, 50 or 60 Hz,

110 V, 50 or 60 HzAmplitude: self-readjusting,

max. apx. 2 mmControl: programmableWeight: apx. 38 kg

The EML 300 standard model can accom-modate up to 14 half-height test sieves with300 mm diameter.Sound absorbing cupboard optional.

HAVER EML 300 digital plus N for wet screening

8

Test Sieve Shaker HAVER EML 300 digital plus Twith self-readjusting amplitude; G-Control

Page 9: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

9

Test Sieve Shaker HAVER EML 450 digital plus Twith self-readjusting amplitude; G-Control

– For test sieve diameters: 200 mm, 8” (203 mm), 250 mm, 300 mm, 305 mm, 315 mm, 350 mm, 400 mm, 450 mm

– Programmable, storing functions– Three-dimensional sieving action– All electronic control– Digital indication of all functions– Max. weight of full sieve tower: 15 kg

TECHNICAL DATA:Operation voltage: 230 V, 50 or 60 Hz,

110 V, 50 or 60 HzAmplitude: self-readjusting,

max. apx. 2 mmControl: programmableWeight: apx. 100 kg

The EML 450 can accommodate up to 12test sieves with 400 mm diameter.Sound absorbing cupboard optional.

HAVER EML 450 digital plus Nfor wet screening

Page 10: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

Test Sieve Shaker HAVER UWL 400 TExtremely powerful and silent

– For test sieve diameters: 200 mm, 8” (203 mm), 300 mm, 305 mm, 315 mm, 350 mm, 400 mm

– Three-dimensional sieving action – Driven by two rotary current unbalanced

motors– Max. weight of full sieve tower: 20 kg

TECHNICHE DATEN:Operation voltage: 230 V, 50 Hz,

others on requestControl: programmable

0-599 minutes or continuousoperation

Weight: apx. 190 kg

The HAVER UWL 400 Test Sieve Shaker withits two unbalanced motors is the most efficientof our Test Sieve Shakers and achieves optimumresults.This machine is especially designed for coarse-grained products.The standard version can be fitted with amaximum of 12 test sieves with 400 mm dia-meter.Sound absorbing cupboard optional.

HAVER UWL 400 Ex(not illustrated)

– explosion-proof (temperature class Eex II T 4)

HAVER UWL 400 Nfor wet sieving

HAVERUWL 400 H

for test sieves with beechwood frame

300 x 300 mmor 500 x 500 mm

10

Page 11: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

Test Sieve Shakers Tyler Ro-Tap®

These test sieve shakers reproduce the circular and tapping motion of hand sieving, but with an even mechanical action, assuring constant and comparable analyses. They are operated by a vertically mounted, totally enclosed 1/4 hp motor. All machine types are adapted to EC-standards.

Test Sieve Shaker Tyler Ro-Tap® 8" RX-29Model B – ISO 9284For test sieves with 8" (203 mm) or 200 mmdiameter.It can be fitted with 6 test sieves with 50 mmeffective height or 10 test sieves with 25 mmeffective height and a sieve pan.Sound absorbing cupboard optional.

TECHNICAL DATA:Digital time switch: 0-99 minutesOperating voltage: 230 V, 50 Hz or

110 V, 60 HzRevolutions per min.: 278 ± 10Taps per min.: 150 ± 5Weight: apx. 82 kgDimensions: 710 x 530 x 635 mm

(w x d x h)

Test Sieve ShakerTyler Ro-Tap® 12“ RX-30

Test Sieve ShakerTyler Ro-Tap® II-RX-94

Test Sieve ShakerTyler 8“ RX-812

For test sieves with 12" (305 mm) or300 mm diameter. It can be fitted with6 test sieves with 50 mm effectiveheight or 10 test sieves with 30 mmeffective height and a sieve pan.Technical data: see RX-29

For test sieves with 8" (203 mm) or200 mm diameter. It can be fittedwith 2 sieve sets of 6 test sieves with50 mm effective height or 10 testsieves with 25 mm effective heighteach.Technical data: see RX-29Dimensions: 780 x 780 x 750 mm

(w x d x h)Weight: apx. 100 kg

Weighing only 25 kg, these test sieveshakers are handy and transportable.The sieving action is horizontallywithout tapping. Recommended siev-ing materials are coarse-grainedproducts (more than 150 µm). Depending on the type, the machinescan be fitted with up to 6 test sieveswith standard or up to 10 test sieveswith half effective height each. Fortest sieves from 200 mm to 305 mmdiameter.

11

Page 12: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

The cleaner the test sieves, the more exact the sieving results. The HAVER-USC-apparatus and the HAVER-USC-cleaningfluid have proved most reliable for a deep and thorough cleaning.

Test Sieve Cleaners

HAVER USC 200Single Sieve Cleaning

HAVER USC 500Single Sieve Cleaning

HAVER USC 200 Multi

For test sieves up to an outer diameterof 230 mm.– Time switch up to 15 minutes or

continuous operation– High-frequency-constant maximum

output:2 x 240 VA/period, 35 kHz

– Operating voltage: 230 VFrequency regulator 50 - 60 Hz

For test sieves up to an outer diameterof 500 mm.– Time switch up to 15 minutes or

continuous operation– High-frequency-constant maximum

output:2 x 600 VA/period, 35 kHz

– Operating voltage: 230 VFrequency regulator 50 - 60 Hz

For the simultaneous, vertical cleaning of up to 5 test sieves with 200 or203 mm diameter.– Time switch up to 15 minutes or con-

tinuous operation– High-frequency-constant maximum

output: 2 x 1000 VA/period, 35 kHz– Operating voltage: 230 V

Frequency regulator 50 or 60 Hz

12

Page 13: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

13

Sample Splitters and Sample Reducer

Sample splitters and sample reducers are used for dividing sieve material into representative test sieve samples.HAVER sample splitters divide sieve material into two representative samples by a divider consisting of a number ofalternatively arranged partitions.The TYLER® sample reducer accomplishes a 16 to 1 reduction by several dividing steps.

HAVERSample Splitters25 – 37.5 –50 – 75

Rack made from lacquered sheetsteel, one stainless steel divider, threereceivers made from tinned sheetsteel. The divider is available with12 divisions, 6.3 mm = 1/4"18 divisions, 12.5 mm = 1/2"Special execution with dust protec-tion available.

HAVERSample Splitters6.3 – 12.5

Rack, one divider and three receiversmade from galvanized steel.The divider is available with16 divisions, 25 mm = 1”12 divisions, 37.5 mm = 11/2”

8 divisions, 50 mm = 2”6 divisions, 75 mm = 3”

TYLER®

Sample ReducerRX-18

The TYLER® Sample reducer reduceslarge material samples to workabletesting sizes. It accomplishes a 16 to 1 reduction and maintains a repre-sentative size distribution in one process. The maximum particle size is 12.7 mm = 1/2”.

Page 14: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

14

(b) ASTM Supplementary values© Copyright 2003 by HAVER & BOECKER

ASTM E 11 oASTM E 323 ● ■

Woven Wire Cloth Drahtgewebe Round Holes ● Rundlochung Square Holes ■ Quadratlochung

International Test Sieve Comparison Table 2003TEST SIEVES, NOMINAL SIZES OF OPENINGS

Internationale Analysensieb-Vergleichstabelle 2003SIEBBÖDEN FÜR ANALYSENSIEBE (Prüfsiebe) Maschen- bzw. Lochweiten

125–1 mmTABLE 1

1 2 3 4 5 6 7 8 9 10 11

DEU

DIN

DIN ISO3310

AFNORNF ISO 3310

CAN/CGSB-

8.2-M88metric

BS 410ISO 3310

NEN2560

TYLER Screen Scale

FRA

NF

CANGBR NLD

N

USA TYLER®ISO 565 . ISO 3310Table 1, Millimetre sizes

Principal sizesHauptreihe

R 20/3

ISO 3310-1 Woven Wire Cloth

Round Holes

Square HolesISO 3310-2

R 20

2000 2001

125–1

125–1

125–4

125–1 125–1125–1

125–1

125–4

125–1

125–4

2000 1988

R 40/3

w w w

125

90

63

45

31,5

22,4

16

11,2

8

5,6

4

2,8

2

1,4

1

125

112

100

90

80

71

63

56

50

45

40

35,5

31,5

28

25

22,4

20

18

16

14

12,5

11,2

10

9

8

7,1

6,3

5,6

5

4,5

4

3,55

3,15

2,8

2,5

2,24

2

1,8

1,6

1,4

1,25

1,12

1

125

106

90

75

63

53

45

37,5

31,5

26,5

22,4

19

16

13,2

11,2

9,5

8

6,7

5,6

4,75

4

3,35

2,8

2,36

2

1,7

1,4

1,18

1

w

125

112

106

100

90

80

75

71

63

56

53

50

45

40

37,5

35,5

31,5

28

26,5

25

22,4

20

19

18

16

14

13,2

12,5

11,2

10

9,5

9

8

7,1

6,7

6,3

5,6

5

4,75

4,5

4

3,55

3,35

3,15

2,8

2,5

2,36

2,24

2

1,8

1,7

1,6

1,4

1,25

1,18

1,12

1

w

125

112

106

100

90

80

75

71

63

56

53

50

45

40

37,5

35,5

31,5

28

26,5

25

22,4

20

19

18

16

14

13,2

12,5

11,2

10

9,5

9

8

7,1

6,7

6,3

5,6

5

4,75

4,5

4

3,55

3,35

3,15

2,8

2,5

2,36

2,24

2

1,8

1,7

1,6

1,4

1,25

1,18

1,12

1

ww No. Meshw

125

112

100

90.0

80.0

71.0

63.0

56.0

50.0

45.0

40.0

35.5

31.5

28.0

25.0

22.4

20.0

18.0

16.0

14.0

12.5

11.2

10.0

9.0

8.0

7.10

6.30

5.60

5.00

4.50

4.00

3.55

3.15

2.80

2.50

2.24

2.00

1.80

1.60

1.40

1.25

1.12

1.00

125

106

100 (b)

90

75

63

53

50 (b)

45

37.5

31.5

26.5

25.0 (b)

22.4

19.0

16.0

13.2

12.5 (b)

11.2

9.5

8.0

6.7

6.3 (b)

5.6

4.75

4.00

3.35

2.80

2.36

2.00

1.70

1.40

1.18

1.00

5 in.

4.24 in.

4 in. (b)

3.1/2 in.

3 in.

2.1/2 in.

2.12 in.

2 in. (b)

1.3/4 in.

1.1/2 in.

1.1/4 in.

1.06 in.

1 in. (b)

7/8 in.

3/4 in.

5/8 in.

0.530 in.

1/2 in. (b)

7/16 in.

3/8 in.

5/16 in.

0.265 in.

1/4 in. (b)

3.1/2

4

5

6

7

8

10

12

14

16

18

1.05 in.

.883 in.

.742 in.

.624 in.

.525 in.

.441 in.

.371 in.

2.1/2

3

3.1/2

4

5

6

7

8

9

10

12

14

16

125

112

106

100

90

80

75

71

63

56

53

50

45

40

37,5

35,5

31,5

28

26,5

25

22,4

20

19

18

16

14

13,2

12,5

11,2

10

9,5

9

8

7,1

6,7

6,3

5,6

5

4,75

4,5

4

3,55

3,35

3,15

2,8

2,5

2,36

2,24

2

1,8

1,7

1,6

1,4

1,25

1,18

1,12

1

w

125

112

106

100

90

80

75

71

63

56

53

50

45

40

37,5

35,5

31,5

28

26,5

25

22,4

20

19

18

16

14

13,2

12,5

11,2

10

9,5

9

8

7,1

6,7

6,3

5,6

5

4,75

4,5

4

3,55

3,35

3,15

2,8

2,5

2,36

2,24

2

1,8

1,7

1,6

1,4

1,25

1,18

1,12

1

2000 1998

125–1

125–1 125–1

125–3.35

125–1

125–4

2001 1910

26,5–1

Supplementarysizes

Nebenreihen

Page 15: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

15

w w w

710

500

355

250

180

125

90

63

45

R’10

32

25

20

16

10

5

900

850

800

710

630

600

560

500

450

425

400

355

315

300

280

250

224

212

200

180

160

150

140

125

112

106

100

90

80

75

71

63

56

53

50

45

40

38

36

32

25

20

16

10

5

900

850

800

710

630

600

560

500

450

425

400

355

315

300

280

250

224

212

200

180

160

150

140

125

112

106

100

90

80

75

71

63

56

53

50

45

40

38

36

32

25

20

16

10

5

900

800

710

630

560

500

450

400

355

315

280

250

224

200

180

160

140

125

112

100

90

80

71

63

56

50

45

40

36

900

800

710

630

560

500

450

400

355

315

280

250

224

200

180

160

140

125

112

100

90

80

71

63

56

50

45

40

36

32

850

710

600

500

425

355

300

250

212

180

150

125

106

90

75

63

53

45

38

900

850

800

710

630

600

560

500

450

425

400

355

315

300

280

250

224

212

200

180

160

150

140

125

112

106

100

90

80

75

71

63

56

53

50

45

40

38

36

32

25

20

900

850

800

710

630

600

560

500

450

425

400

355

315

300

280

250

224

212

200

180

160

150

140

125

112

106

100

90

80

75

71

63

56

53

50

45

40

38

36

32

25

20

16

10

5

850

710

600

500

425

355

300

250

212

180

150

125

106

90

75

63

53

45

38

32

25

20

15

10

5

20

25

30

35

40

45

50

60

70

80

100

120

140

170

200

230

270

325

400

450

500

635

20

24

28

32

35

42

48

60

65

80

100

115

150

170

200

250

270

325

400

450

500

635

w w ww No. Meshww

© Copyright 2003 by HAVER & BOECKER

ASTM E 11 oASTM E 161 m

Electroformed Elektrogeformte Siebfolie

International Test Sieve Comparison Table 2003TEST SIEVES, NOMINAL SIZES OF OPENINGS

Internationale Analysensieb-Vergleichstabelle 2003SIEBBÖDEN FÜR ANALYSENSIEBE (Prüfsiebe) Maschen- bzw. Lochweiten

900–5 µmTABLE 2

1 2 3 4 5 6 7 8 9 10 11

DEU

DIN

DIN ISO3310

AFNORNF ISO 3310

BS 410ISO 3310

NEN2560

TYLERScreen Scale

FRA

NF

CANGBR NLD

N

USA TYLER®ISO 565 . ISO 3310Table 2, Micrometre sizes

Principal sizesHauptreihe

R 20/3

ISO 3310-1 Woven Wire Cloth

ElectroformedISO 3310-3

R 20

2000 2001

900–20

500–5

900–20

500–5

900–32900–20

2000 1988

R 40/3

CAN/CGSB-

8.2-M88metric

2000 1998

900–20

500–5

850–20 850–20

500–5

2001 2000 1910

850–20

Supplementarysizes

Nebenreihen

Woven Wire Cloth Drahtgewebe

Page 16: Test Sieve Shakers, Test Sieves and Laboratory · PDF fileTest Sieve Shakers, Test Sieves and Laboratory Equipment HAVER ... sieves by a video-analysis-system ... Test Sieve Shakers

HAVER & BOECKERWIRE WEAVING AND ENGINEERING WORKS

Ennigerloher Straße 64 • D-59302 OELDE, GermanyPhone: +49-25 22-300 • Fax: +49-25 22-30404

E-Mail:[email protected] • Internet: http://www.haverboecker.com

Postal Address: HAVER & BOECKER • D-59299 OELDE

The use of the latest technology and equipment for quality control guaranteethe highest and constant quality of our woven wire cloth products.

Our methodical quality management system is certified to DIN EN ISO 9001 : 2000

P 42

E 3

98 0

4200

3 2

Fe

Prin

ted

in G

erm

any

© H

AV

ER &

BO

ECK

ER. A

ll ri

gh

ts o

n a

ny

kin

d o

f re

pro

du

ctio

n, i

n w

ho

le o

r p

art,

res

erve

d.

HAVER CPA 3-2

HAVER CPA Online application for crusher control in the mineralprocessing technology

HAVER CPA 4 – Dual Range

HAVER CPA Scan Weighing System

Quality Management System

certified by DQS againstDIN EN ISO 9001