tender document · providing reinforcement for rcc work including straightening ... bressummers...

100
INDIAN INSTITUTE OF TECHNOLOGY GUWAHATI Guwahati - 781 039, Assam Phone : (0361) 2582061, 2692771 : : Fax : (0361) 2692771 , 2690762 TENDER DOCUMENT NIT NO: IITG/ENGG/17/NIT/01 Dated: 19.01.2017 Part – B : Price Bid NAME OF WORK Extension of Academic Complex Phase-VI (CIF & CET Building) at IITG Campus.

Upload: others

Post on 13-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

INDIAN INSTITUTE OF TECHNOLOGY GUWAHATI

Guwahati - 781 039, Assam

Phone : (0361) 2582061, 2692771 : : Fax : (0361) 2692771 , 2690762

TENDER DOCUMENT

NIT NO: IITG/ENGG/17/NIT/01 Dated: 19.01.2017

Part – B : Price Bid

NAME OF WORK

Extension of Academic Complex Phase-VI (CIF & CET Building) at

IITG Campus.

Page 2: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl. No. Particulars Amount (Rs.)

1

PART - A : Building Works

PART - B : Sanitary and Water Supply Installation

PART - C : Site Development Work

PART - D : Electrical Works

PART - E : HVAC Works

PART - F : Passenger Lift

2

PART - A : Building Works

PART - B : Sanitary and Water Supply Installation

PART - C : Electrical Works

Total =

Technology (CET) Building and Construction of Central Instruments Facility (CIF) Building at

IITG campus, Guwahati

Construction of Centre for Educational Technology (CET) Building :

Construction of Central Instruments Facility (CIF) Building :

ABSTRACT OF COST

Name of Work : Extension of Academic Complex (Phase-VI) – Construction of Centre for Educational

PART - C : Electrical Works

PART - D : HVAC Works

Interest bearing mobilisation advance (if required) =

Non-Interest bearing mobilisation advance (if required) =

Grand Total (Sl. No. 1 + 2) =

Rebate if any =

Total after rebate =

Total =

(Rebate shall be given at this space in the form of percentage of the rates quoted and rebate given in any other place other than this space, shall not be acceptable)

Page 3: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1 BORED CAST IN SITU PILE

a Boring, providing and installing bored cast-in-situ reinforced cement concretepiles of specified capacity, diameter and length by DMC mechanical meansas per specifications, drawings below the pile cap in cement concrete ofgrade-M30 to carry a safe working load not less than the specified excludingcost of steel reinforcement but including the cost of boring, casing of alllengths, bentonite, concreting and all other arrangements as requiredetc.and the length of the pile to be embedded in the pile cap as specified inthe specifications (effective length of pile for payment will be measured frombottom of the pile up to the cut off level of piles. Rate shall includearrangement of all equipments and drilling mud etc. 500 mm dia. Piles

Metre 8160.00

b Vertical load testing of pile in accordance with IS:2911 (Part-IV) includinginstallation of loading plateform and preparation of pile head or constructionof test cap and dismantling of test cap after test etc. complete as perspecification and direction of engineer-in-Charge.(capacity up to 100 tonnes)

(i) Initial test (Test Load 2.5 times the Design load) Per test 2

PART - A : Building Works

Name of Work : Construction of Centre for Educational Technology (CET) Building

(ii) Routine test (Test Load 1.5 times the Design load) Per test 4

c Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead up to 50mand lift up to 1.5m: All kinds of soil

sqm 1,000.00

2 EARTH WORK IN EXCAVATION

(a) Earth work in excavation in foundation trenches and drains including bailingout water, dressing of sides, shoring & strutting, ramming of bottoms,including all lifts from the existing ground level and getting out the excavatedsoil, disposal of excavated soil at suitable places within the IIT campus asdirected including refilling the foundation trenches with approved qualityselected excavated / imported soil (excluding rock) etc. including bailing outwater before filling in layers

Cum 1,107.00

Page 4: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

not exceeding 20 cm in depth; consolidating/compacting each depositedlayer to the acceptable density by ramming and watering all complete asdirected with all leads and lifts. (Measurements for excavation in foundationfor footings shall be taken on vertical lines with 300 mm tolerance all aroundthe finished concrete of the foundation and that for plinth beams/walls or anyother structure, shall be made on vertical lines with tolerance 150mm aroundthe finished surfaces of concrete. No extra payment shall be made onaccount of removal of slipped earth and backfilling thereof, dewatering,shoring & strutting, etc.) a) In all types of soil

3 EARTH WORK IN FILLING

Earth work in filling in Plinth with approved quality granular soil under floors,plinth beam, etc. as per drawing and as directed including watering,ramming, consolidating upto acceptable limit of 90% proctor density anddressing complete.( The rate shall be inclusive of providing soil including allleads and lifts, payment for land compensation for obtaining earth, paymentof royalty , taxes etc.)

Cum 722.00

4 ANTI-TERMITE TREATMENT

Providing and injecting chemical emulsion for pre-constructional anti-termitetreatment and creating a chemical barrier under & all-round the column pits,wall trenches, basement excavation, top surface of plinth filling, junction ofwall and floor, along the external perimeter of building, expansion joints,surroundings of pipes and conduits etc. complete. Stages shall be treated asper CPWD specification. (Plinth area of the building at ground floor level onlyshall be measured for payments).- With Chlorpyriphos Emulsifiable

Sq.M. 985.00

shall be measured for payments).- With Chlorpyriphos Emulsifiableconcentrate 20% with 1% concentration.

5 CEMENT CONCRETE WORK

Providing,vibrating, laying in position cement concrete of specified gradeincluding curing but excluding the cost of centring and shuttering in all worksupto floor-V level.

(a) 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominalsize) Cum 224.00

(b) 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mmnominal size) Cum 42.00

Page 5: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

( c ) Providing and laying damp proof course 40 mm thick with cement concrete1:2:4 (1 cement: 2 course sand: 4 graded stone aggregate 12.5 mm nominalsize) with approved quality water proofing compound in cement concrete and cement mortar work at the rate as recommended by the manufacturers.

Sq.M. 98.50

(d) Applying a coat of residual petroleum bitumen of penetration 80/100 0fapproved quality using 1.7kg per square metre on damp proof course aftercleaning the surface with brushes and finally with a piece of cloth lightlysoaked in kerosene oil.

Sq.M. 98.50

(e) Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mmbed by dry brick ballast 40mm nominal size well rammed and consolidatedand grouted with fine sand including finshing the top smooth.

Sq.M. 150.00

6 STEEL REINFORCEMENT

Providing reinforcement for RCC work including straightening, cutting,bending, binding with specified wire & placing in position complete as perspecifications and drawings - Fe 500 D grade super ductile steel ofapproved manufacturers only of all diameters as per relevent IS codes.

kg 701,608.00

7 CENTERING AND SHUTTERING

Providing, fitting and fixing of centring and shuttering including strutting,propping etc., & removal of forms at all heights and levels for concrete workto give desired surface finish on the concrete.

(a) Foundations, footings, pile caps, bases of columns, mass concrete , etc. Sq.M. 605.00

(b) Walls of any thickness including attached pilasters, buttress, plinth and string course etc.

Sq.M. 911.00

( c) Suspended floors, roofs, inclined roofs and balconies / projections andchajjas, shelves.

Sq.M. 5,781.00

(d) Lintels, beams, girders, bressummers & cantilevers including sloping beams. Sq.M. 6,486.00

Page 6: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(e) Column, pillars, posts & struts. Sq.M. 2,966.00

(f) Staircase plain/folded plate including landings. Sq.M. 460.00

(g) Vertical and horizontal fins individually or forming box louvers, band andfacias and eaves boards.

Sq.M. 479.00

(h) Extra for shuttering in circular work (20% of respective centering andshuttering items)

Sq.M. 220.00

(i) Small lintels not exceeding 1.5 m clear span, moulding as in cornices,window sills, string courses, bands, copings, bed plates, anchor blocks andthe like

Sq.M. 69.00

8 REINFORCED CEMENT CONCRETE

Providing and laying in position machine batched and machine mixed designmix M-25 grade cement concrete for reinforced cement concrete work, usingcement content as per approved design mix, including pumping ofconcrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommendedproportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability as per direction ofEngineer-in-charge. All works at all heights and level.Engineer-in-charge. All works at all heights and level.

(a) In rafts, footings, pile caps, bases of columns and footing beams etc.Cum 839.00

All works above plinth level upto floor V level

(b) In lintels, beams, bressummers, suspended floors, roofs including inclinedroof, landings, balconies, chajjas, staircases etc. upto floor five level. Cum 1537.00

( c) In walls (of any thickness) including attached pillarsters, buttresses, plinthand string courses, fillets, column, pillars, piers, abutments posts and strutsetc. up to floor five level.

Cum 343.00

Page 7: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(d) Reinforced cement concrete work in vertical and horizontal fins individuallyor forming box louvers, facias and eaves boards up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mmnominal size).

Cum 22.00

(e) Providing, hoisting and fixing upto floor five level pre-cast reinforced cementconcrete in shelves including setting in cement mortar 1:3 ( 1 cement : 3coarse sand) cost of required centring, shuttering and finishing with neatcement punning on exposed surfaces but excluding the cost ofreinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5mm nominal size)

Cum 8.50

All works above floor V level

(f) In lintels, beams, bressummers, suspended floors, roofs including inclinedroof, landings, balconies, chajjas, staircases etc. upto floor five level. Cum 392.00

(g) In walls (of any thickness) including attached pillarsters, buttresses, plinthand string courses, fillets, column, pillars, piers, abutments posts and strutsetc. up to floor five level.

Cum 78.00

(h) Reinforced cement concrete work in vertical and horizontal fins individuallyor forming box louvers, facias and eaves boards up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mmnominal size).

Cum 5.00

9 MASONRY WORKS

(a) Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:

Cum 104.00designation 7.5 in foundation and plinth in:

Cum 104.00

Cement mortar 1:4 (1 cement : 4 coarse sand)

(b) Providing and laying autoclaved aerated concrete (AAC) blocks masonrywith 100/150/200 mm thick AAC blocks in super structure above plinth levelup to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rateincludes providing placing in position 2 nos of 6mm dia MS bar at every thirdcoarse of masonry works.

Cum 1119.00

( c) Making circular opening for exhaust fan up to 600 mm dia in brick/AAC workby providing precast RCC ring of required diameter complete as directed byEngineer-in-Charge.

Each 24

(d) Extra for brick work / AAC block masonry / Tile brick masonry insuperstructure above floor V level, for each four floors or part thereof bymechanical means.

Cum 208.00

Page 8: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

10 FLOORING

(a) Providing flat brick soling under foundation, floor, plinth beam includingpacking with coarse sand and watering etc complete as directed with bricksclass designation-75 in cement mortar in proportion 1:4 including curingcomplete as specified and as directed.

Sq.M. 1017.00

(b) 100 mm thick cement concrete in floors in proportion 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) over flat bricksoling with brick of designation 75 (to be measured and paid separately)including curing etc. complete as directed.

Sq.M. 15.50

( c) 40mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with floating coat ofneat cement slurry.

Sq.M. 323.00

( d) Extra over item no.10(c) for finishing with NITOFLOR HARDTOP/equivalentof approved shade as per manufacturers specifications in place of floatingcoat of neat cement cement slurry complete as per drawing and as directedby the Engineer-in -charge

Sq.M. 323.00

(e) Stone tile (polished) work for wall lining over 12 mm thick bed of cementmortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqmincluding pointing in white cement complete.

8mm thick

Granite of any colour and shade Sq.M. 280.00

(f) Providing and laying flamed finish Granite stone flooring in required design(f) Providing and laying flamed finish Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with cement slurry and pointing with white cementslurry admixed with pigment of matching shade including rubbing, curing andpolishing etc. all complete as specified and as directed by the Engineerin-Charge :

Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eyeor equivalent.

Sq.M. 496.00

Page 9: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

( g) Providing and fixing markana Chak doongri marble stone of averagethickness 18mm to 20mm over 20 mm thick base mortar of proportion 1:4 (1cement : 4 coarse sand) laid and jointed with tiles jointing compound ofmatching shade including half round moulding of the nose, rubbing andpolishing complete in all respects including cutting the stone to makenoutch/offset on all corners vertical and horizontal and moulding as per

noutch detail in drawing and directed in window sills

Sq.M. 17.00

(h) Extra over item no. 10(g) for mirror polishing of marble stone surfaces. Sq.M. 17.00

(i) Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finishetc.complete as per design approved by Engineer-in-Charge.

Metre 584.00

Granite work

(j) Providing and fixing stone slab with table rubbed, edges rounded andpolished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions bycutting a chase of appropriate width with chase cutter and embedding thestone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.

Sq.M. 6.00

Granite Stone of approved shade

(k) Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shade of theslab, including rubbing and polishing complete with base of cement mortar 1jointed with grey cement slurry mixed with pigment to match the shade of theslab, including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand) : 25 mm thick

Sq.M. 359.00

(l) Providing and laying in floor Group -V matt finished ceramic tile of minimumthickness 7.8mm without warpage of approved design and manufacturerlaid on 20mm thick cement mortar 1:3(1cement:3 sand) including filling thejoints with pigmented tile joint filler Nitotile-GR or equivalent of matchingshade and approved manufacturer as per manufacturers specification etc.and cleaning the surface with detergent and water complete.Size 400 mm x 400mm..

Sq.M. 120.00

Page 10: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(m) Providing and laying polished vitrified tiles in floors and skirting in differentsizes with water absorption's less than 0.08% and conforming to IS: 15622of approved make in all colours and shades,laid on 20mm thick cementmortar 1:3 (1 cement : 3 coarse sand) including grouting the joints withapproved tile jointing compound of matching colour etc.complete. Size ofTile 1000x1000 mm

Sq.M. 4560.00

(n) Providing and laying matt finished vitrified tile of size 300x300x9.8mm havingwith water absorption less than 0.5% and conforming to IS: 15622 ofapproved make in all colours and shades in for outdoor floors such asfootpath, court yard, multi modals location etc., laid on 20mm thick base ofcement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patternsincluding grouting the joints with white cement mixed with matching pigmentsetc. complete as per direction of Engineer-in-Charge.

Sq.M. 150.00

(o) Extra for providing opening of required size & shape for wash basins, kitchensink in kitchen platform, vanity counters and similar locations in mable/granite/ stone work including necessary holes for pillar tapes etc. includingrubbing and polishing of cut edges etc. complete.

Each 28

11 DADO, SKIRTING, STEPS & RISERS

(a) Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser ofsteps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarsesand), including grouting the joint with white cement & matching pigments

Sq.M. 373.00sand), including grouting the joint with white cement & matching pigmentsetc. complete.Size of Tile 1000x1000 mm

(b) Providing and fixing ceramic tiles of approved design & shade and ofminimum thickness 5.6mm thick in dado/skirting in any pattern and size over12mm thick cement mortar 1:3(1cement : 3 coarse sand ) and filling thejoints with Nitotile-GR or equivalent of matching shade as per manufacturersspecification etc and cleaning the surface with detergent and watercomplete. Size-300mm x 600 mm

Sq.M. 490.00

(c) Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laidon 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) andjointed with grey cement slurry mixed with pigment to match the shade of theslabs, including rubbing and polishing complete.

Sq.M. 85.00

Page 11: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(d) Extra for nosing of the stone edges as per detail and polishing the same togive mirror finish as directed by Engineer in Charge. Rm 658.00

12 DOORS AND WINDOWS

(a) Providing and fixing pressed steel door frames confirming to IS:4351manufactured from commercial mild sreel sheet of 1.6mm thicknessincluding hinges ,jamb,lock jamb,bead and if required angle threshold of mildsteel angle of section 50x25mm or base ties of 1.6mm pressed mild steelwelded or rigidly fixed together by mechanical means,adjustable lugs withsplit end tail to each jamb including steel but hinges 2.5mm thick with mortarguards,lock strike plate and shock absorber as specified and applying a coatof approved steel primer after ptre treatment of the surface as directed byEngineer-in Charge a) Profile-B

Rm 410.00

(b) Providing and fixing ISI marked flush door shutters conforming to IS: 2202(Part) decorative, core of block construction with frame of 1st class hardwood and well matched teak 3 ply veneering with vertical grains or crossbands and face vanees on both faces of shutters.

Sq.M. 153.00

35 mm thick including ISI marked Stainless Steel built hinges with necessaryscrews.

(c ) Providing and fixing ISI marked flush door shutters conforming to IS : 2202(Part I) non-decorative type, core of block board construction with frame of1st class hard wood and well matched commercial 3 ply veneering withvertical grains or cross bands and face veneers on both faces of shutters:

30 mm thick including ISI marked Stainless Steel butt hinges with necessaryscrews

Sq.M. 11.00

(d) Providing and fixing glazing in doors, windows and ventilators shutterscompete as per architectural drawings and the directions of Engineer-in–charge.

With clear glass panes of 5.0 mm thickness (weight not less than 13.75kg/sqm)

Sq.M. 370.00

(e) With float glass panes of 8 mm thickness

Sq.M. 65.00

(f) With frosted glass panes of 5.0 mm thickness (weight not less than13.75kg/sqm) Sq.M. 48.00

Page 12: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

13 ALUMINIUM WINDOWS

(a) Providing and fixing powder coated aluminium work for doors,windows(catchment/sliding), ventilators, partitions or any other places withextruded built up standard tubular and other sections of approved makeconfirming to IS:733 and IS: 1285, anodised transparent according to IS:1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs andscrews or with fixing clips, or with expansion hold fasteners includingnecessary filling up of gaps at junction, at top, bottom and sides withrequired PVC/ neoprene felt, silicon sealants etc. to make perfactlywatertight. Aluminium sections shall be smooth , rust free, straight, andjointed mechanically wherever required including cleat angle, aluminiumsnap beading for glazing/ panelling, C.P./ stainless steel screws, hinges allcomplete as per architectural drawings and the directions of Engineer-in-Charge. (Glazing and panelling shall be paid separately)

Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminium snapbeading for glazing / paneling, C.P. brass / stainless steel screws, allcomplete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

kg 5527.00

For fixed portions like outer frames etc

(b) For shutters of doors, windows & ventilators including providing and fixinghinges/ pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber / neoprene gasket required (Fittings shallbe paid for separately)be paid for separately)

Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron)

kg 3423.00

( c) Providing and fixing of double action heavy duty Hydraulic door spring ofapproved make (hardwyn or equivalent) Each 78

(d) Providing and fixing 12mm prelaminated three layer medium density(exteriorgrade) particle board Grade-I, type-II conforming to IS:12823 bonded withphenol formaldehyde synthetic resin of approved brand and manufacturer inpanelling fixed in aluminium door shutter with C.P./ Brass/ stainless steelscrews etc. complete as per Architectural drawings and the direction ofEngineer-in-charge

Sq.M. 115.00

Page 13: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(e) Providing and fixing 12mm thick frameless toughened glass door shutter ofapproved brand and manufacture, including providing and fixing top &bottom pivot & spring type fixing arrangement and making necessary holesetc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately)

Sq.M. 15

(f) Providing and fixing aluminium casement window stainless steel frictionstays of required length for aluminium windows with necessary screws etc.complete.

pair 21

14 PARTITIONS AND FALSE CEILING WORKS

(a) Providing and fixing false ceiling at all height including providing and fixing offrame work made of special sections, power pressed from M.S. sheets andgalvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS :277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick withflanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixedto the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm diabolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm ofrequired length with nuts & bolts of required size and other end of anglehanger fixed with intermediate G.I. channels 45x15x0.9 mm running at thespacing of 1200 mm centre to centre, to which the ceiling section 0.5 mmthick bottom wedge of 80 mm with tapered flanges of 26 mm each havinglips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a directionperpendicular to G.I. intermediate channel with connecting clips made

Sq.M. 4079.00

Page 14: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixingperimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the perimeter of ceiling fixed to wall/partition with the help ofrawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mminterval, including fixing of gypsum board to ceiling section and perimeterchannel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,including jointing and finishing to a flush finish of tapered and square edgesof the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides ofjoint and two coats of primer suitable for board, all as per manufacturer’sspecification and also including the cost of making openings for light fittings,grills, diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction of theEngineer in Charge but excluding the cost of painting with

12.5 mm thick tapered edge gypsum moisture resistant board

(b) 98mm thick metal stud partition which includes one layer of tapered edge13mm thick DURALINE gypboard of India gypsum or equivalent (confirmingto IS:2095-1982) screw fixed with drywall screws of 25mm at 300mm centresto either sides of 70mm studs (0.55mm thick having one flange of 34mm &another flange of 36mm made GI steel) placed at 610mm centre to centre in72mm floor and ceiling channel (0.55mm thick having equal flanges of 32mm made GI steel) with joints staggered to avoid leakage through joints. Finallythe square and tapered edges of the boards are to be joined and finished soas to have a flush look which includes filling and finishing with jointing Sq.M. 420.00as to have a flush look which includes filling and finishing with jointingcompound. Joint paper tape and two coats of drywall top coat suitable forgypboard including angle bead to be at external angles to get straight linefinish & protection from normal impacts and edge bead to be used to protectthe exposed gypsum core of gypboard specially at cut edges of the openingfor doors/ windows/ glazig or any other unprotected core complete as per thedrawing & direction of engineer-in-charge (as per recommended practices ofIndia gypsum)

Sq.M. 420.00

15 STEEL WORK

(a) Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete.

Fixed to openings /wooden frames with rawl plugs screws etc. Kg 3348.00

Page 15: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(b) Steel work in built up tubular ( round, square or rectangular hollow tubesetc.) trusses etc.,including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including welding and bolted withspecial shaped washers etc. complete.

Kg 23058.00

Hot finished welded type tubes

( c) Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railing withnecessary accessories & stainless steel dash fasteners , stainless steelbolts etc., of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.).

Kg 6665.00

(d) Providing, fabrication and fixing of structural glazing made out of colouredanodised aluminium mother frame (INDAL 9303) and subframe (INDAL9406)and 5mm reflective glass of approved shade. The glass to be pasted usingstructural silicon (DC995) and weatherseal silicon to be used (DC789), thestructure complete with all accessories as and where necessary.

Sq.M. 444.00

16 WOOD & P.V.C. WORK

(a) Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or withdash fasteners of required dia & length ( hold fast lugs or dash fastener shall

Cum 4.00dash fasteners of required dia & length ( hold fast lugs or dash fastener shallbe paid for separately).

Second class teak wood

( b) Providing and fixing Pre-laminated flat pressed 3 layer (medium density)particle board or graded wood particle board IS : 3087 marked, with one sidedecorative and other side balancing lamination Grade I, Type II exteriorgrade IS : 12823 marked, in shelves with screws and fittings whereverrequired, edges to be painted with polyurethane primer (fittings to be paidseparately).

Sq.M. 145.00

18 mm thick

(c) Extra for providing lipping with 2nd class teak wood battens 25 mm minimumdepth on all edges of flush door shutters (over all area of door shutter to bemeasured).

Sq.M. 153.00

Page 16: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(d) Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flatpressed three layer particle board or graded wood particle board IS: 12823marked, exterior grade (Grade l Type ll), having one side decorativelamination and other side balancing lamination, including IInd class teakwood lipping of 25 mm wide x12 mm thick with necessary screws and brightfinished stainless steel piano hinges, complete as per direction of theEngineer-in-Charge

Sq.M. 45.00

17 TERRACING

( a) Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A,including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.

Metre 450.00

110 mm diameter

( b) Providing and fixing on wall face un-plasticised - Regid PVC moulded fittingsconforming to IS : 13592 type-A including jointing with seal ring conformingto IS : 5382 leaving 10 mm gape for thermal expansion

Coupler

110 mm Each 225

Bend 87.5°

110 mm bend Each 18

Shoe (Plain)

110 mm Shoe Each 18

( c) Providing and fixing unplasticised -PVC pipe clips of approved design tounplasticised - PVC rain water pipes by means of 50x50x50 mm hard woodplugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and makinggood the wall etc. complete.

Each 225

110 mm

(d) Providing gola 75x75mm in cement concrete 1:2:4 (1cement:2coarsesand:4 graded stone aggregate 10mm and down size) including finishingwith cement mortar 1:3( 1cement:3 fine sand) as per standard design. In75x75mm deep chase.

Metre 148.00

Page 17: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

( e) Making khurras 45x45 cm with average minimum thickness of 5cm cementconcrete 1:2:4 (1cement:2 coarse sand:4 graded stone aggregate 20mmnominal size) over 1mX1mx 400 micron PVC sheet finished with 12mm thickcement plaster 1:3 (1cement:3 coarse sand) and a coat of neat cementrounding the edges and making and finishing the outlet complete.

Each 18

( f) Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams. Each 18

( h) Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as perIS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side ofthe sheet and polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratches duringtransportation and should be supplied in single length upto 12 metre or asdesired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins,rafters and trusses and including cutting to size and shape whereverrequired.

Sqm 444

( i) Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqmas per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns using self drilling/ self

Rm 163.00as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns using self drilling/ selftapping screws complete :

Rm 163.00

Flashings/ Aprons.( Upto 600 mm)

( j) Providing & Fixing of 12mm thick UV protected polycarbonate panels withopaque & Transluscent combination for aesthetic appeal with verticalstanding seam on both sides, snap on locking system. The system will befitted on MS rafters/Purlin (will be paid separately) with spacing as specifiedby manufacturer.

Sq.M. 466.00

18 WATER PROOFING

(a) Providing water proofing treatment with best quality acrylic polymer modifiedcementitious composite slurry quoating and fibre glass cloth of approvedbrand over sunken floors roof and terraces as per manufacturer'sspecification and as approved by Engineer-in-Charge.

Sq.M. 265.00

Page 18: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(b) Providing and laying water proofing treatment on roofs of slabs by applyingcement slurry mixed with water proofing cement compound consisting ofapplying: a) after surface preparation, first layer of slurry of cement @ 0.488kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. b)laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layerof 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixedwith water proofing cement compound @ 0.670 kg/sqm and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by watercuring for 48 hours. The entire treatment will be taken upto 30 cm on parapetwall and tucked into groove in parapet all around. d) fourth and final layer ofbrick tiling with cement mortar (which will be paid for separately. For thepurpose of measurement the entire treated surface will be measured.

Sq.M. 946.00

( c) Grading roof for water proofing treatment with

Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size)

Cum 66.00

(d) Cement mortar 1:4 (1cement : 4 coarse sand) Cum 66.00

19 FINISHING

(a) 12 mm thick cement plaster on even surface of wall with cement mortar 1:4(1 cement : 4 sand)

Sq.M. 18734.00

(b) 15 mm thick cement plaster on the rough side of single or half brick wall with(b) 15 mm thick cement plaster on the rough side of single or half brick wall withcement mortar of 1:4 (1 cement : 4 sand) Sq.M. 8847.00

( c) 6 mm plaster to ceiling in cement mortar 1:3 (1 cement : 3 sand) Sq.M. 5500.00

( d) 20mm thick cement plaster 1:3(1 cement : 3 coarse sand) finished with afloating coat of neat cement slurry damp proof on wall between plinth leveldifference.

Sq.M. 180.00

( e) 18 mm thick cement mortar plastering consisting of 12mm undercoat ofcement mortar 1:4(1 cement : 4 coarse sand) with 6mm thick finishing coatof cement mortar 1:3(1cement:3 fine sand) to give desired pattern oversloping roof

Sq.M. 444.00

Page 19: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(f) Neat cement punning. Sq.M. 454.00

(g) Providing and applying wall care putty of Birla White/JK white or equivalentat all heights and levels on the entire surface including removal ofundulations and sand papering the wall after the surface is dry to get asmooth and even surface

Sqm 27581.00

(h) Providing and applying cement primer of approved manufacturers overprepared surface Sq.M. 27581.00

(i) Finishing walls with textured exterior paint of required shade

New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and includingpriming coat of exterior primer applied @ 2.20kg/ 10 sqm

Sq.M. 250.00

(j) Finishing walls with water proofing cement paint or equivalent of approvedcolour, Shade and anufacturer and as per direction of Engineer-in -charge -New Work

Sq.M. 300.00

(k) Finishing walls with fungus and algae resistant superior grade water proofacrylic paint of approved shade and brand to give an even shade to allexternal wall surfaces(two or more coats) including surface preparation togive an even surface as per manufacturer's specification

Sq.M. 8847.00

(l) Applying priming coat :

With ready mixed pink or Grey primer of approved brand and manufactureon wood work (hard and soft wood)

Sq.M. 420.00

(m) Painting with synthetic enamel paint of approved brand and manufacture to(m) Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on wood work/ steel work in allshades

Sq.M. 1624.00

(n) Varnishing with varnish of approved brand and manufacture

Two or more coats of glue sizing with copal varnish over an under coat offlatting varnish

Sq.M. 306.00

(o) Providing and applying on walls two or more coats of Acrylic emulsion ofapproved shades and manufacturer. Sq.M. 18734.00

(p) Providing and applying on walls and ceiling two or more coats of Acrylicwashable distemper of approved shades and manufacturer. Sq.M. 5500.00

Page 20: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

20 BUILDING HARDWARE

(a) Providing 40x5 mm flat iron hold fast 40 cm long including fixing to framewith 10 mm diameter bolts, nuts and wooden plugs and embedding incement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand: 6graded stone aggregate 20mm nominal size).

Each 1000.00

(b) Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers of approved quality including necessary screwsetc. complete.50 mm

Each 68

( c ) Providing and fixing aluminium sliding door bolts, ISI marked anodisedanodic coating not less than grade AC 10 as per IS : 1868), transparent ordyed to required colour or shade, with nuts and screws etc. complete :

Each 114

300x16 mm

(d) Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed torequired colour or shade, with necessary screws etc. complete :

Each 246

300x10 mm

(e) Providing and fixing aluminium handles, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade, with necessary screws etc. complete :

125 mm

Each 142

100 mm

Each 68

(f) Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessary screwsetc. complete.

Single rubber stopper

Each 38

Twin rubber stopper

Each 78

Page 21: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(g) Providing and fixing aluminium round shape handle of outer dia 100 mm withSS screws etc. complete as per direction of Engineerin-charge

Polyester powder coated minimum thickness 50 micronaluminium

Each 156

21 MISCELLANEOUS ITEMS

(a) Under Deck (Roof) Insulation:SINGLE LAYER SYSTEM UNDER DECKTHERMAL INSULATION SYSTEM WITH INSU.BOARD

Sq.M. 790.00

Cleaning of the surface by brush

(b) Day Time use Building: Providing & Laying of Insuboard, thickness 50mm ofdensity 32 kgs/ cum over the RCC CEILING ( Plastered Surface) frominside. The insuboard will be fixed over the wall surface by the PVC Fastner(side lap) (Make: M/S Supreme or equivalent)

Sq.M. 790.00

PARTITIONS AND ASSOCIATED WORKS

Toilet Cubical

( d) Providing & fixing Greenlam Sturdo Classique Versatile Toilet Cubicle (of

following standard dimension which includes 600mm door size width) made

of heat, bacteria, water, chemical, scratch, impact and anti bacterial

resistant 12mm thick solid compact laminate panels tested by Shriram

Test House. Finish of the compact laminate should be Suede, which

includs doors, pilasters & intermediate panels finished with approvedtexture/shade as per the detail drawings & as per IS 2046 (Indian Standard)

and as per fire retardant BS-476/97 standard. The product should have

Green Guard Certificate.

This also includes providing and fixing in position necessary hardware made

No. 11.00

This also includes providing and fixing in position necessary hardware madeout of Stainless steel (Grade 304) &

Aluminium powder coated top rail as per manufacturer’s specifications &Architects instructions like (1) SS Door Knob, (2) SS Gravity hinges, (3) SSThumb turn lockset indicators, (4) Aluminum Powder Coated Top Rail, (5)SS Coat Hooks, (6) SS U-Channels, (7) SS Adjustable Foot, (8) NoiseDeafening Tape etc. (9) Screws & wall Plugs.The top fitting should consist of Aluminium Powder Coated top rail which willget fixed with Mid & End pilasters. All other hardware & screws will of stainless steel in 304 Grade with satinfinish. Top rail is extruded Aluminium will be powder coated or anodized(Grade 6063 Micron Aluminium). All pilasters are supported by stainlesssteel adjustable footing with non corrosive steel inserts.

Page 22: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Toilet Cubicle with standard dimension of 1955mm Height x 1000mm

Width x 1550mm Depth, which includes 600mm door size width).

Toilet Cubicle I-Shape (Front Partition) with standard dimension of

1955mm Height x 1000mm Width which includes 600mm door size width).

All aspects specified by the manufactures, Greenlam Sturdo Classique

Versatile Model or equivalent.

TOTAL (PART - A : Building Works)

Page 23: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushingcistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required:

White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot rests

Each 4

2 Providing fitting and fixing Vitreous china wall hang water closet (Europeantype W.C pan 400mm high) with seat and lead ,CP brass hinges and rubberbuffers , CI/MS brackets , 40 mm dia flush band with fittings includingpainting of fittings and brackets, required. (Flushing Cistern to be paidseparately)

a) Parryware make

Indus walvit Pan set (inclusive of seat cover and fittings) (white) Each 21

3 Providing and fixing white vitreous china flat back or wall corner type lippedfront SENSOR operated urinal basin of approved size. (Sample to beapproved by the engineer in charge)

Each 14

4 Providing and fixing toilet paper holder :

C.P. brass Each 21

PART - B : Sanitary and Water Supply Installation

Name of Work : Construction of Centre for Educational Technology (CET) Building

C.P. brass Each 21

5 Providing and fixing one piece construction white vitreous china squattingplate with an integral longitudinal flushing pipe, white P.V.C. automaticflushing cistern, with fittings, standard size G.I. / PVC flush pipe for back andfront flush with standard spreader pipes with fittings, G.I clamps and C.P.brass coupling complete, including painting of fittings and cutting and makinggood the walls and floors etc. wherever required :

Single squatting plate with 5 litre P.V.C. automatic flushingcistern

Each 3

6 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with minimum distances of 37 mm from wall face with concealedfittings arrangement of approved quality and colour, weighing not less than88 gms.

Each 28

Page 24: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

7 Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws with concealed fitting arrangement of approvedquality and colour. 600mm long towel rail with total length of 645mm, width78mm and effective height of 88mm, weighing not less than 190gms.

Each 20

8 Providing and fixing square-mouth S.W. gully trap grade 'A' complete withC.I. grating brick masonry chamber with water tight C.I. cover with frame of300x300mm size (inside) the weight of cover to be not less than 4.50 kg andframe to be not less than 2.70 kg as per standard design: 100x100mm sizeP type. With F.P.S. Bricks class designation 75.

Each 21

9 Providing vitreous china counter-top wash basin of size 490mm dia ofHindware make with 32mm CP brass waste coupling of standard pattern,C.P brass chain with plug, PVC waste pipe including painting of fittings andbrackets, cutting and making good the wall and slabs wherever required.

Each 27

a) Coloured vitreous china counter-top wash basin of size 490mm dia

10 Providing, fitting and fixing recessed soap tray of Hindware make completeas specified and directed, Coloured. Size 216mm x 108mm. Each 27

11 Providing and fixing 600x450mm bevelled edge mirror of superior glass (ofapproved quality) complete with 6mm thick hard board ground fixed towooden cleats with C.P. brass screws and washers complete.

Each. 27

12 Supplying and fitting fixing C.P. pillar cock of 15mm dia of 5011 of Jaquarbrand as specified and directed. Each 56brand as specified and directed. Each 56

13 Providing and fixing 600x120x5 mm glass shelf with edges rounded offsupported on anodised aluminium angle frame with C.P. brass brackets andguard rail complete fixed with 40mm long screws, rawl plugs etc. complete.

Each 27

14 Providing fitting and fixing C.P. Grating to the floors complete as directedand specified.

Circular type

100 mm nominal dia Each 35

15 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including paintingof fittings and brackets, cutting and making good the walls wherever required:

Each 1

Kitchen sink with drain board

510x1040 mm bowl depth 250 mm

Page 25: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

16 Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required :

Each 28

Size 600x450x200 mm

17 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.

Semi rigid pipeEach 56

32 mm dia

18 Providing and fixing PTMT Waste Coupling for wash basin and sink, ofapproved quality and colour.

Waste coupling 38 mm dia of 83 mm length and 77mm breadth,weighing not less than 60 gms

Each 27

19 Providing and fixing PTMT Bottle Trap for Wash basin and sink.

Bottle trap 31mm single piece moulded with height of 270 mm, effectivelength of tail pipe 260 mm from the centre of the waste coupling, 77 mmbreadth with 25 mm minimum water seal, weighing not less than 260 gms

Each 27

PP- R PIPES

20 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesSDR 7.4, U V stabilized & anti - microbial fusion welded, having thermalstability for hot & cold water supply, including all PP - R plain & brassthreaded polypropylene random fittings, i/c fixing the pipe with clamps at1.00 m spacing. This includes testing of joints complete as per direction of1.00 m spacing. This includes testing of joints complete as per direction ofEngineer in Charge.

Internal work - Exposed on wall

18.4.3 PN - 16 Pipe, 25 mm OD Metre 40.00

18.4.4 PN - 16 Pipe, 32 mm OD Metre 70.00

18.4.5 PN - 16 Pipe, 40 mm OD Metre 100.00

Page 26: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

21 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesSDR 7.4, U V stabilized & anti - microbial fusion welded, having thermalstability for hot & cold water supply, including all PP - R plain & brassthreaded polypropylene random fittings, i/c fixing the pipe with clamps at1.00 m spacing. This includes the cost of cutting chases and making goodthe same including testing of joints complete as per direction of Engineer inCharge.

Concealed work, including cutting chases and making good the

walls etc.,

PN - 16 Pipe, 16 mm OD

Metre 90.00

PN - 16 Pipe, 20 mm OD

Metre 110.00

PN - 16 Pipe, 25 mm OD

Metre 90.00

BRASS FITTINGS

22 Providing and fixing brass bib cock of approved quality :

15 mm nominal bore Each 28

23 Providing and fixing brass stop cock of approved quality :

15 mm nominal bore Each 62 15 mm nominal bore Each 62

24 Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete :

15 mm nominal bore Each 15

25 Providing and fixing uplasticised PVC connection pipe with brass unions :

45 cm length

15 mm nominal bore Each 24

Page 27: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

26 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cementmortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside)with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4graded stone aggregate 20mm nominal size ) , i/c necessary excavation,foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stoneaggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neatcement complete as per standard design :

With common burnt clay F.P.S.(non modular) bricks of classdesignation 7.5

Each 10

27 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.

Each 27

PVC PIPES,BENDS,JUNCTIONS,TEES ETC.

28 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) orother ISI approved including joining ,fitting and fixing with clamps etc.asnecessary complete at all levels including below G.L as directed andspecified.

a) In exposed surfaces or in trenches.

110 mm dia Metre 120.00

75 mm diameter : Metre 95.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

110 mm dia Metre 190.00

75 mm diameter : Metre 185.00

Page 28: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

29Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) orother ISI approved including joining ,fitting and fixing etc.as necessarycomplete at all levels including below G.L as directed and specified.

a) In exposed surfaces or in trenches.

110 mm dia Each 25.00

75 mm diameter : Each 15.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

110 mm dia Each 20.00

75 mm diameter : Each 10.00

30 Supplying fiting and fixing 87.5 degree PVC bend with door of(Supreme/Prince) or other ISI approved including joining , fitting and fixingetc. as necessary complete at all levels including below G.L. as directed andspecified.

a) In exposed surfaces or in trenches.

110 mm dia Each 25.00110 mm dia Each 25.00

75 mm diameter : Each 15.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

110 mm dia Each 20.00

75 mm diameter : Each 10.00

31Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) orother ISI approved including joining , fitting and fixing etc. as necessarycomplete at all levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

110 mm dia Each 25.00

Page 29: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

75 mm diameter : Each 15.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

110 mm dia Each 20.00

75 mm diameter : Each 10.00

32Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or otherISI approved including joining, fitting and fixing etc. as necessary completeat all levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

110 mm dia Each 25.00

75 mm diameter : Each 15.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.good to the damages.

110 mm dia Each 15.00

75 mm diameter : Each 15.00

33 Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) orother ISI approved including joining , fitting and fixing etc. as necessarycomplete at all levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

Page 30: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

110 mm dia Each 15.00

75 mm diameter : Each 15.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

110 mm dia Each 15.00

75 mm diameter : Each 15.00

34 Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISIapproved including joining , fitting and fixing etc. as necessary complete atall levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

110 mm dia Each 15.00

75 mm diameter : Each 15.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

110 mm dia Each 10.00

75 mm diameter : Each 10.00

TOTAL (PART - B : Sanitary and Water Supply Installation)

Page 31: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1 Earth work in excavation over areas (exceeding 30 cm in depth, 1.5 m inwidth as well as 10 sqm on plan including disposal of excavated earth,including all lead and lift, disposal earth to be leveled and neatly dressed : All types of soil

Cum 64.8

2 Earthwork in filling for site preparation with approved quality earth includingfilling the portion within plinth area upto the formation level, peripheral apron& drains etc. complete upto the formation level in layers not exceeding 20cm in depth including watering, ramming, consolidating to the acceptable densityand dressing complete as directed including obtaining earth and removal oftop vegetation ,dressing the surface upto proper grade and slope. (The rateshall be inclusive of providing earth including all lead and lifts, payment forland compensation for obtaining earth, payment of royalty, taxes etc. thepayment of earthwork shall be made in profile measurement.)

Cum 786.6

3 Earth work in excavation for foundation trenches and drains including bailingout water, dressing of sides, shoring & strutting, ramming of bottoms,including all lifts from the existing ground level and getting out the excavatedsoil, disposal of excavated soil at suitable places within the IIT campus asdirected including refilling the foundation trenches with approved qualityselected, excavated/ imported soil (excluding rock) etc. in trenches, plinth, Cum 64.8

PART - C : Site Development Work

Name of Work : Construction of Centre for Educational Technology (CET) Building

selected, excavated/ imported soil (excluding rock) etc. in trenches, plinth,sides of foundations etc., including bailing out water before filling in layersnot exceeding 20cm in depth; consolidating/compacting each depositedlayer to the acceptable density by ramming and watering all complete asdirected with all leads and lifts.

Cum 64.8

(retaining wall manholes, sewer line etc.) (Measurements for excavation forfoundation of columns shall be taken on vertical lines with 300mm toleranceall around the finished concrete of foundation and that for plinth beams/wallsor any other structures, shall be made on vertical lines with tolerance of150mm around the finished surfaces. No extra payment will be made onaccount of removal of slipped earth and backfilling thereof, dewatering,shoring & strutting, etc.)

Page 32: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

4 Brick work with bricks of class designation 75 in foundation & plinth incement mortar 1:4 (1 cement : 4 coarse sand) Cum 36.45

5 20mm thick cement plaster 1:3(1 cement : 3 coarse sand) finished with afloating coat of neat cement slurry damp proof on wall between plinth leveldifference.

Sqm 306.00

6 Cement concerete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size) in pavements, laid to required slope andcamber in panels as required including consolidation finishing and tempingcomplete.

Cum 16.2

7 Providing and laying interlocking precast cement concrete paver of approveddesign and compressive strength of 300kg/sqcm laid on a bed of 40mm thickcoarse sand including filling the joints with local sand complete 75mm

sqm 170

8 Labour for consolidaiton of stone metal (construction of Water BoundMacadam) including local carriage of materials within one Km. Spreadingthe stone metal evenly and uniformly over the prepared sub-grade and sub-base, between prepared shoulders in layers of thickness not exceeding100mm (loose)/200mm (loose) incase of 53.22.4mm size aggregates, testingthe depth with depth blocks and surface with templates, correcting the highand low spots by adding or removing, stones, dry rolling with a power rollerof 8-10 tonnes, commencing rolling from the edges, running the rollersforward and backward until the edges are fimrly compacted, progressingrolling from edges to centre, parallel to the centrline of the road and lappinguniformly the preceeding rear wheel by one half width, rolling on until theuniformly the preceeding rear wheel by one half width, rolling on until theentire area of the surface has been rolled by the rear wheel and until theroad metal is throughly keyed and creeping of stone ahead of the roller is nolonger visible,slight sprinkling of water, if required, adding or removingmaterials after lossening, if necessary, to keep the longitudinal and the crossprofile within the permissible tolerance limits, checking the profile withtemplate and straight edges, applying screenings in 3 or more applications ata uniform and slow rate, dry rolling till the surface is free from any deformity,copiously sprinkling water (to be supplied by the contractor), sweepingrolling, applying additional screenings and water forms ahead of the roller,applying binding materials (to be supplied by the contractor) and sufficientwateing and rolling until a paste of blindge and water beings to flow ahead ofthe roller, (WBM will be measured as finsiehd work in position for thecompacted thickness)

cum 40

Page 33: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

9 Turfing with selection No.1 grass including watering and maintenance of the lawn for 30 days

or more till the grass forms a thick lawn, free from weeds and fit for mowing including

supplying good earth, if needed (the good earth shall be paid for separately).Sqm 120

10 Constructing brick masonry circular type manhole 0.91 m internal dia atbottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand),in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with a floating coat of neat cement, foundationconcrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standarddesign : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20grade designation) 560 mm internal diameter conforming to I.S. 12592, totalweight of cover and frame to be not less than 182 kg., fixed in cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) including centering,shuttering all complete. (Excavation, foot rests and12mm thick cement plaster at the external surface shall be paid forseparately) : With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5

Each 25

11 Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth upto 30 cm measured at a height of 1 m aboveground level and removal of rubbish upto a distance of 50 m outside theperiphery of the area cleared.

Sq.M. 1311.00

TOTAL (PART - C : Site Development Work)

Page 34: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1.0 POINT WIRING AND SUBMAIN WIRING

1.1

Wiring for light point / fan point / exhaust fan point / call bell point with 1.5sq.mm. PVC insulated, FR, multistrand copper conductor cable in surface/recessed medium class PVC conduit complete with modular switch, modularplate, suitable G.I. box and earthing the point with 1.5 sq.mm, FR PVC insulatedcoper conductor single core cable etc., as required..

Point 935

1.2

Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with1.5 sq.mm FR PVC insulated copper conductor single core cable etc. asrequired.

Point 68

1.3Wiring for submain with the following sizes of PVC insulated, FR copperconductor, single core cable in surface/recessed PVC conduit, as required.

a) 3 X 1.5 sq.mm Mtr. 1120

b) 3 X 2.5 sq.mm Mtr. 2600

PART - D : Electrical Works

Name of Work : Construction of Centre for Educational Technology (CET) Building

b) 3 X 2.5 sq.mm Mtr. 2600

c) 3 X 4 sq.mm Mtr. 36000

d) 3 X 6 sq.mm Mtr. 1500

e) 6 X 4 sq.mm Mtr. 2050

Page 35: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

f) 6 X 2.5 sq.mm Mtr. 1360

g) 6 X 6 sq.mm Mtr. 1200

h) 2 X 10 sq.mm + 1 X 6 sq.mm earth wire Mtr. 800

i) 4 X 10 sq.mm + 2 X 6 sq.mm earth wire Mtr. 2700

j) 4 X 16 sq.mm + 2 X 6 sq.mm earth wire Mtr. 2550

1.4Supplying & fixing suitable size G.I. box with modular plate & cover in front onsurface or in recess, including providing & fixing, 3/5 pin 5/6 Amp. modularsocket outlet and 5/6 Amp. modular switch. connections etc., as required.

No. 340

1.5Supplying & fixing suitable size G.I. box with modular plate & cover in front onsurface or in recess, including providing & fixing 6 pin 15/16 Amp. Modularsocket outlet and 15/16 Amp. modular switch, connections, etc., as required.

No. 510

1.6Supplying & fixing following size / modules, G.I. box along with modular base &cover plate for modular switches / sockets in recess etc., as required.

a) 1 or two module (75 mm x 75 mm) No. 200

b) 3 module (100 mm x 75 mm) No. 50

c) 4 module (125 mm x 75 mm) No. 80

Page 36: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

d) 6 module (200 mm x 75 mm) No. 200

e) 8 module (125 mm x 125 mm) No. 350

f) 12 module (200 mm x 150 mm) No. 180

1.7Supplying & fixing following modular switch / socket on the existing modularplate and switch box including connections, but excluding modular plate etc. asrequired.

a) 5/6A switch No. 400

b) 15/16A switch No. 600

c) 3/5 pin 5/6A socket No. 900

d) 6 pin 15/16A socket No. 800d) 6 pin 15/16A socket No. 800

1.8Supplying and fixing two module stepped type electronic fan regulator alongwith two module box cover plate etc. complete.

No. 25

1.9Supply & installation including connection to existing wiring etc. of followingpresence detectors / movement detector -

a) High sensitivity detector - area of detection, 1-7 m for Class rooms, Cat.-Hager / EE883 or equivalent.

No. 16

Page 37: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b) Single lens, 360°, 6 m dia detector, 10A, AC, 1 Channel surface / flushmounted for corridor / toilet - Cat.- Hager - EE804 / 805 or equivalent.

No. 48

1.10Supply & installation of modular 20 A, DP, Energy Key switch with boxes & allaccessories.

No. 16

2.0 CABLING

2.1 Supplying of following PVC/XLPE insulated cable 1.1 KV grade

a) 3.5 C 300 sq.mm Mtr. 800

b) 3.5 C 185 sq.mm Mtr. 200

2.2Laying of one number PVC/XLPE insulated and sheated 1.1KVgrade Aluminiumarmoured power cable of following size in ground including excavation & sandcushioning, brick protection and refilling etc. all complete.

a) above 185 sq.mm and upto 400 sq mm M 380

Laying of one additional number PVC/XLPE insulated and s sheathed cable 1.1KV grade aluninium armoured cable of following size direct in ground in same

2.3KV grade aluninium armoured cable of following size direct in ground in sametrench in one tier horizonal formation including excavation, sand cushioning,protective brick covering and refilling etc., as required size exceeding 120sq.mm but not exceeding 400 sq.mm

a) above 185 sq.mm and upto 400 sq mm M 380

2.4Laying of one number PVC/XPLE insulated and sheated 1.1KV gradeAluminium armouredpower cable of following size in duct pipe/trench etc.

a) above 95 sq.mm and upto 185 sq mm Mtr. 200

Page 38: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b) above 185 sq.mm and upto 400 sq mm Mtr. 40

2.5Supplying and making end termination with brass compression gland andaluminioum lig the following size of PVC/XLPE insulated conductor cable of1.1KV grade, as required.

a) 3½ C 300 sq.mm Set 4

b) 3½ C 185 sq.mm Set 20

3.0 DISTRUBTION BOARDS / MV PANEL

3.1Supplying and fixing of miniature circuit breaker with 'C' curve, 10 KA offollowing poles in the existing MCB DB complete with connections, testing andcommissioning etc., as required (5-32A).

a) Single pole No. 786

b) Double pole No. 24

c) Triple pole No. 32

d) Triple pole & netural No. 18

3.2Supplying and fixing single pole, blanking plate in the existing MCB DBcomplete etc. as required.

No. 60

Page 39: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

3.3

Supplying and fixing 20amps, 240 volts, SPN industrial type, socket outlet, with2 pole and earth, metal enclosed plug top along with 20amps C-series, SP,MCB in sheet steel enclosure, on surface or in recess, with chained metal coverfor the socket outlet, and complete with connections, testing and commissioningetc. as required.

No. 50

3.4

Supplying and fixing 30amps, TPN industrial type socket outlet, with 4 pole andearth, metal enclosed plug top along with 30amps "C' series TP MCB in sheetenclosure, on surface or in recess, with chained metal cover for the socketoutlet and complete with connection, testing, commissioning as required.

No. 30

3.5

Supplying and fixing of following way single pole and netural, steel, dustprotected double door type MCB distribution board 240 volts, onsurfacew/racess complete with loose wire box, terminal blocks, tinned copperbusbar, neutral link, earth bar, din bar, detachable gland plate, inter-connections, including power coated painting,earthing etc., as required.

a) 8 way, Double door No. 12

b) 12 way, Double door No. 12

Supplying, installation, testing and commissioning of surface/recess mounting,horizontal type, double door 415 volts, TPN MCB distrubtionboard of sheet

3.6

horizontal type, double door 415 volts, TPN MCB distrubtionboard of sheetsteel, 1.6 mm thick, dust protected, duly phosphatized and painted, inclusive of200amps tinned copper busbars, earth bar, common neutral link, din bar formounting MCB's detachable gland/kNo.ck out plates, hinged front acrylic coerand with built in loose wire box, and superior make terminal connectiors for allincoming and outgoing circuits, duly prewired with adequate size of PVCinsulated copper wires between the busbars and the MCB's as well as theincomer and upto the terminal connectors/neutral link and ready for installation,of followin ways (but without the supply of outgoing MCB's/Isolator)

a) 6 way (4+18), Double door No. 18

Page 40: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

3.7

Supplying, installation, testing and commissioning of surface/recess mounting,vertical type, double door, 415 volts, TPN MCB distrubtion board of sheet steel,1.6 mm thick, dust protected, duly phosphatized and painted, inclusive of200amps tinned copper busbars, earth bar, common neutral link, din bar formounting MCB's detachable gland/kNo.ck out plates, hinged front acrylic coverand with built in loose wire bix, and superior make terminal connectiors for allincoming and outgoing circuits, duly prewired with adequate size of PVCinsulated copper wires between the busbars and the MCB's as well as theincomer and upto the terminal connectors/neutral link and ready for installation,of following ways complete with supply of one 100A, 16 KA, TP MCCB at theincomer (but without the supply of outgoing MCBs)

a) 8 way (4+24), Double door No. 15

3.8

Fabrication, supplying, installation, testing & commissioning of wall/floormounted cubicle board out of 2mm thick CRCA MS sheet steel, havingmountings as detailed below in suitable size compartments, lockingarrangement for each compartment including interconnection with 1100V gradePVC insulated copper conductor of size as that of sunmains, labelling, earthing,brass compression glands for incoming and outgoing cables and suitableadapter box for outgoing submains:

SDBSDB

Incomer: No. 6

200A FP MCCB, 35 KA breaking capacity having 70%-100% adjustable thermalseeting - 2 Nos.

200A FP, 35 KA breaking capacity Bus Coupler breaker - 1 No.

2 Sets digital multifunction meter for measurement of current, voltage, KWh,KVAh & p.f., current Transformer, Selector Switches indicating Lammps at theincoming for both incomings.

Bus Bar:

200A 4 Strip Aluminioum Bus Bar - 2 Sections

Outgoing in each Section :

100A TP MCCB, 25KA breaking capacity - 5 Nos.

63A TP MCCB, 25KA breaking capacity - 4 Nos.

32A DP MCB - 4 Nos.

Page 41: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

4.0 LIGHTING FIXTURE & FANS

4.1Installation, testing and commissoning of wall bracket / ceiling fittings of all sizesof LED fittings on ceiling/wall recessed or surface including connections with 1.5sq.mm PVC insulated, copper conductor, single core cable etc., as required.

No. 725

4.2Installation of exhust fan upto 450mm sweep in the existing opening, includingmaking the hole to suit the size of the above fan, making good the damage,connections, testing, commissioning etc., as required.

No. 30

4.3Installation, testing & commissioning of ceiling fan including wiring the downrods of standard length (upto 30 cm) with 3 x 1.5 sq.mm copper wire single corecable as required.

No. 25

4.4Supplying & fixing extra conduit down rod of 20 cm length G.I. pipe, 15 mm dia,heavy gauge including painting etc. as required.

No. 50

4.5Supply of following light fittngs (LED) complete with all accessories such asholders, copper/HF ballast, wherever required, etc. complete factory wired witcopper conductor and lamp as required.

(i) RC 380B G2 LED 35S-6500 PSU OD WH - 2 x 2 square LED recessed fittingof Philips

No. 280

(ii) BN 150W LED 20S-6500 PSE OD GR - LED batten of Philips. No. 220

(iii) DN192B LED 9S-6500 PSU WH SI round LED recessed light of Philips No. 225

Equivalent fittings from Philips / Crompton / Wipro / Syska / Havells may beused subject to approval. All LED fittings shall have 5 years warranty from themanufacturer w.e.f from the date of supply.

4.6 Supply of following energy efficient 5-Star rated ceiling fan -

a) 1200 mm sweep No. 25

Page 42: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

4.7 Supply of following heavy duty Exhaust fans with louvers

a) 300 mm sweep No. 30

4.8 Supply & installation of 450 mm sweep wall mounted bracket fan. No. 18

5.0 EARTHING AND LIGHTNING PROTECTION

5.1Earthing with G.I. earth pipe 4.5m long X 40mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. ( with charcoal or coke and salt) complete, as required.

Set 10

5.2

Earthing with G.I. earth plate 600mm X 600mm X 6mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and waterting pipe etc. (with charcoal or coke and salt) complete,as required.

Set 6

5.3Supplying and laying 25mm X 5mm G.I. strip at 0.50m below ground level asstrip earth electrode, including soldering etc., as required.

Mtr. 50

5.4Providing and fixing 25mm X 5mm G.I. strip in 40mm dia G.I. pipe from the earthelectrode, as required.

Mtr. 40

5.5Providing and fixing 25mm X 5mm G.I. strip on surface or in recess for

Mtr. 1255.5Providing and fixing 25mm X 5mm G.I. strip on surface or in recess forconnections etc., as required

Mtr. 125

5.6Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loopearthing along with the existing surface/recessed conduit/submain wiring/cableas required

Mtr. 30

5.7Providing and fixing of lightning conductor final made of 25mm dia, 300mm longG.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. plateincluding holes etc., as required.

No. 8

5.8Revetting, sweating and soldering of copper/G.I. tape (with aNo.thercopper/G.I> tape, base of the finial or any other metalic object) as required.

No. 80

Page 43: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

5.9Providing and fixing G.I. tape 20mm X 3mm thick on parapet on surface of wallfor lighting conductor as required. (for horizontal run)

Mtr. 250

5.10Providing and fixing G.I. tape 20mm X 3mm thick on parapet or surface of wallfor lighting conductor as required. (for vertical run)

Mtr. 250

5.11Providing and fixing testing joint, made of 20mm X 3mm thick G.I. strip, 125mmlong, with 4 Nos. of G.I. bolts, nuts, check nuts and spring washers etc.complete as required.

No. 15

6.0 WIRING FOR TELEPHONE

6.1Wiring for telephone points/tag blocks/call indicator units with following sizePVC insulated annealed tinned electrolytic copper conductor cable in existingrecessed conduits, ducts, shafts etc. (cost includes supply of wires)

a) 0.5 mm dia 2 pair Mtr. 3200

6.2Providing and fixing in posotion telephone junction box complete with hingeddoor having locking arrangement with following tag blocks.

a) 50 pair tag block No. 2

b) 20 pair tag block No. 6

6.3Supplying and fixing of 2 pin Telephone jack RJ-11 modualr type in compatiablebox along with cover plate etc. complete

No. 150

6.4Supplying and fixing of following size of PVC conduit along with the acessoriesin surface/recess incuding painting in case of surface conduit, or cutting the wallmaking good the same in case of recessed conduit as required.

a) 20 mm Mtr. 1200

Page 44: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b) 25 mm Mtr. 900

7.0 JELLY FILLED TELEPHONE CABLE

7.1Supplying of following polyethylene insulated jelly filled armoured telephonecables as per DOT specification.

a) 50 pair, 0.5mm copper armoured cable Mtr. 500

b) 20 pair 0.5 mm copper unarmoured cable Mtr. 200

7.2Excavation and trenching one meter depth and 0.3m width including refillingwith excavated earth after laying of jelly filled telephone cable dressing, sandcushing and protective bricks covering etc as required.

Mtr. 600

7.3Laying of jelly filled cable in trenches (excavated under item 7.2) as per DOTSpecification including transportation, loadning & unloading of cable fromconcernd store depot to work site of following jelly filled cable

a) 50 Pair. Mtr. 500

b) 20 Pair. Mtr. 200

8.0 COMPUTER WIRING AND LAN CABLING

8.1Supplying and laying of UTP 4 pair Cat-6 computer Networking cable n existingPVC conduit and terminaiton etc., as required (one run).

Mtr. 22500

8.2Providing, fitting & fixing of computer point RJ-45 of approved make computersocket in compatiable MS/PVC box, screw etc., as required.

No. 750

Page 45: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

8.3 Supplying & laying of following size PVC conduit recessed in wall/celling

a) 20 mm Mtr. 10000

b) 25 mm Mtr. 8000

8.4 Installation of 6 U wall mounted rack for Patch panel No. 6

9.0 FIRE DETECTION & ALARM SYSTEM

9.1

Supply, installation, testing & commissioning of intelligent plug in photo electricsmoke detectors having features like integral communication, dual LED for 360˚viewing angle, walk test with address display etc. UL / LPCB approved, Make :HONEYWELL, MORLEY IAS, Model : MI - PSE or equiv.

No. 140

9.2

Supply, installation, testing & commissioning of intelligent plug in thermaldetectors having features like integral communication, dual LED for 360˚viewing angle, walk test with address display etc. UL / LPCB approved, Make:HONEYWELL, MORLEY IAS, Model : MI - RHSE or equiv.

No. 15

9.3Supply, installation, testing & commissioning of Addressable hooter completewith control module.UL / LPCB approved, Make - HONEYWELL, MORLEY IAS, No. 129.3 with control module.UL / LPCB approved, Make - HONEYWELL, MORLEY IAS,Model - MI - LASR + NBD / R or equiv.

No. 12

9.4

Supply, installation, testing & commissioning of Dual action pull station withaddressable interface, built in bicolour LED with key reset facility & smooth dualaction design.UL / LPCB listed. Make : HONEYWELL, MORLEY IAS, Model :MI - LASR + NBD / R or equiv.

No. 15

9.5Supply, installation, testing & commissioning of response indicator to give visualindication of detection of smoke - RED colour LED for indication. Make - AgniSuraksha, System Sensor.

No. 30

Page 46: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

9.6

Supply, installation, testing & commissioning of 5 Loop Intelligent / AnalogueAddressable Fire Alarm Panel Microprocessor based character display Networkoption built in Alarm, Trouble & supervisory relays LPCB listed. Make :HONEYWELL, MORLEY IAS, Model - ZX 5 e or equiv.

No. 1

9.7Supply, installation, testing & commissioning of Addressable Base Model -Detectors, LPCB approved, Make - HONEYWELL, MORLEY IAS or equiv.

No. 155

9.8Wiring with 1100V grade PVC insulated copper conductor in existing PVC / MSconduit (including supply of wire)

i) 3 x 1.5 mm2 RM 1300

9.9 Supply and laying of following PVC conduit recessed in wall/ ceiling

i) 20 mm RM 800

10.0 BUS TRUNKING SYSTEM

10.1

Supplying, installing on wall, testing and commissioning of following capacity AirInsulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts,50Hz A.C. supply with enclosure having IP-54 rating after fixing the tap offboxes and all accessories, made of 1.6mm thick steel sheet duly powder coatedin convenient sections complete with 4 Nos aluminium bus bars, having currentdensity of 130 A/ sq.cm at Nominal current rating, necessary joints & expansion

10.1density of 130 A/ sq.cm at Nominal current rating, necessary joints & expansionjoints, fire barrier at each floor, provision of tapping at every metre, continuousearthing with 2 Nos. aluminium strip of suitable size (one on each side)including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.

a) 400 Amp lsc = 30 KA for 1 second Mtr. 50

Page 47: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

10.2

Supplying, installing, testing & commissioning of following capacity End FeedUnit for the existing Air Insulated Compact Type bus trunking / rising mains foruse on 3 phase 4 wire 415 Volts, 50Hz A.C. supply made with 1.6 mm thicksteel sheet enclosure (IP54) duly powder coated with provision of MCCB / ACB(but without MCCB / ACB) complete with necessary joints including clampingbrackets, angle iron bracket, steel fasteners, connecting to earthing system etc.as required.

a) 400 Amps lsc = 30 KA for 1 second No. 4

10.3

Supplying, installation, testing & commissioning of following capacity Plug In /tap off box on the existing Air Insulated Compact Type bus trunking / risingmains for use on 3 phase 4 wire 415 Volts, 50Hz A.C. supply made with 1.6 mmthick steel sheet enclosure (IP54) duly powder coated with provision of MCCB(but without MCCB) complete etc. as required.

a) 200 Amps lsc = 25 KA for 1 second No. 12

10.4Providing & fixing following rating and breaking capacity and pole MCCB withthermo-magnetic release and terminal spreaders in the above end-feed units /tap off boxes including drilling holes etc. making connections etc. as required.

a) 400 Amp, 35 KA, TPMCCB No. 4

b) 200 Amp, 25 KA, TPMCCB No. 12

11.0 MISCELLANEOUS ITEMS

11.1Providing, laying and jointing GI pipes of medium class including excavationand back filling all complete as pipe ducts for passing services through roads,pavements, foundations, floors, etc.)

Page 48: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

a) 50 mm dia Mtr. 20

b) 100 mm dia Mtr. 20

c) 150 mm dia Mtr. 20

11.2

Supplying & installing of perforated, pre-painted M.S. cable trays withperforation No.t more than 17.5% in convenient sections joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts paintingetc., as required.

a) 100 mm width x 50 mm depth x 1.6 mm thick Mtr. 30

b) 150 mm width x 50 mm depth x 1.6 mm thick Mtr. 150

c) 225 mm width x 50 mm depth x 1.6 mm thick Mtr. 20

d) 300 mm width x 50 mm depth x 1.6 mm thick Mtr. 20

TOTAL (PART - D : Electrical Works)

Page 49: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

1 EQUIPMENTUnit Qty

Rate (INR in

Figure) Rate in words Amount(INR)

Double Skin Air Handling Units

1.1

Supply, installation, testing and commissioning of sheet metal sectionalised

construction thermal break type double skin AHU of following capacity with Chilled

water cooling coil, 50 mm thick prefilter having efficiency 90% down to 10 micron,

Microvee Filter Section sutable to accomodate 300 mm Microvee filter, squirrel

cage induction motor,DIDW centrifugal backward curved fan, belt drive package

and vibration isolation (spring mounted), insulated drain pan,thermostate,wiring

etc. as per specification complete as required.

aDouble skin floor mounted AHU 8.0 TR, 3700 CFM, 65 mm SP, 6 RD, 12 FPI with

mixing boxNo 6

bDouble skin floor mounted AHU 4.0 TR, 1600 CFM, 65 mm SP, 6 RD, 12 FPI with

mixing boxNo 5

cDouble skin floor mounted AHU 11 TR, 5400 CFM, 65 mm SP, 6 RD, 12 FPI with

mixing box No 1

dDouble skin floor mounted AHU 12 TR, 5800 CFM, 65 mm SP, 6 RD, 12 FPI with

mixing box No 4

1.2 Double Skin Ceiling Suspended Air Handling Units

aS/I/T/C of Double skin Ceiling suspended AHU 4 TR, 1600 CFM, 35 mm SP, 6 RD,

12 FPI i/c all accessories complete as required.No 3

1.3 Fan Coil Unit

Supply , installation, testing and commissioning of Low height Inverter driven

lownoise fan coil unit complete with hidden/ exposed with 3 RD cooling coils , 3

speed fan, extended drain pan (sandwitched construction only),thermostate,wiring

and pre filters. Suitable for 230 V, 50Hz single phase power connection.Coil face

velocity shall be limited to 350 FPM.

a 2.0TR No 1

b 1.5TR No 17

1.4

Supply, installation, testing and commissioning of Double Skin Plenum Box

with Microvee filter of efficiency 95% down to 3 micron of folloiwng sets along with

necessary trap doors. The Height of the Plenum box should not be more than

1225mm complete as required.

a 4 nos 600 x 600 x 300 (depth Microvee Filter Nos 6

b 6 nos 600 x 600 x 300 (depth) microvee filter Nos 6

1.5

Supply, Installation, Testing & Commissioning of Desicent Rotor Heat recovery

wheel with DIDW Centrifugal Forward Curved Supply & Exhaust fan, Sq. Cage

Motor for Supply & Exhaust fan & HRW Wheel, The unit shall be completely factory

fabricated with purge arrangement and having minimum 65% efficiency complete

as required

a 750 CFM No 1

Name of Work : Construction of Centre for Educational Technology (CET) Building

PART - E : HVAC WORKS

Page 50: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b 300 CFM No 2

1.6 AUTO AIR VENT

a

Supply, installation, testing and commissioning of Auto Air vents at the highest

points in the chilled water piping as per approved makes and specifications 50 mm

Dia Auto Air Vents complete as required.

No 20

1.7

Supply, installation, testing and commissioning of 2kwX3strip heater bank on the

duct with thermostat & dehumidifier,control connection ,DOL starter etc complete

as required,

No 2

2 PIPING

2.1

Supply, Installation, testing & Commissioning of CHILLED WATER PIPING as per

IS 1239 with all necessary supports MS / Civil etc as required as per site condition

and as per specification with MS Heavy class pipe, fittings etc.

2.1.1

Providing and fixing in position the following MS HEAVY class chilled water piping,

cut to required length and installed with welded joints,including at necessary

fittings such as elbow, tees, etc. And confirming to the specifications as detailed

in the relevant chapter in the document.

a 150 mm dia RM 10

b 100 mm dia RM 24

c 80 mm dia RM 68

d 65 mm dia RM 10

e 50 mm dia RM 220

f 40 mm dia RM 440

g 32 mm dia RM 240

h 25 mm dia RM 240

2.2

Providing and fixing of Chilled water pipe insulation with 25 mm thk. Al. Foil Faced

Closed cell Nitrile rubber pipe Section with approved thermal protection layer etc

Complete as required as per specification as required.

a 150 mm dia RM 10

b 100 mm dia RM 24

c 80 mm dia RM 68

d 65 mm dia RM 10

e 50 mm dia RM 220

f 40 mm dia RM 440

g 32 mm dia RM 240

h 25 mm dia RM 240

2.3Providing and fixing of Chilled water pipeline Valve insulation as per chilled water

pipe insulation complete as required.Lot 1

TOTAL CARRIED OVER TO SUMMARY (EQUIPMENT)

Page 51: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

2.4 Drain Water Piping (GI PIPE)

2.4.1Providing and fixing of Condensate drain water pipeline with 19 mm thick al.foil

facia closed cell nitrile rubber pipe section complete as required.

a 50 NB RMT 40

b 25 NB RMT 6

2.5 Drain Water Piping Insulation

condensate drain water insulation with 19 mm thick AL. foil faced closed cell

Nitrile rubber pipe section complete as required

a 50 NB RMT 40

b 25 NB RMT 6

2.6Excavation of trench Trench work to take the chilled water piping upto 250 mm dia

and refilling with excavated soil with compaction with fine sand. RM 20

2.7

Supply, Installation, testing & Commissioning of Underground CHILLED

WATER PIPING with insulation with 75 mm thick expanded. polystyrine of 20

kg/cm3 density .covered with chickenwire mesh,10mm cement sand plaster . 2

layes of terfelt and finally painted the bituminus paint in 2 layers. All the pipes will

be as per IS 1239 with all necessary supports MS / Civil etc as required as per site

condition and as per specification with MS Heavy class pipe, fittings etc comp-lete

as required.a 150mm dia RM 20

b 100mm dia RM 30

3Providing and fixing in position the following insulated butterfly valves i/c all

accessories complete as required..

a 100 mm dia No. 12

b 50 mm dia No 12

c 40 mm dia No 12

d 32 mm No 16

3.1Providing and fixing in position the following insulated ball valves with strainner

complete as required..

a 25 mm dia Set 17

3.2Providing and fixing in position Industrial type pressure gauges with ball valves for

isolation and necessary fittings for the USE of maintenance and operation

complete as required.

No 36

3.3Providing and fixing in position stem alcohol filled industrial thermometers

comple as required.No 36

3.4

Supply, installation, testing and commissioning of insulated Electronic, Self-

balancing Pressure independent type dynamic balancing valve with integrated 2

way modulating control valves in a single body. The actuator shall be capable of

accepting 2 - 10 VDC,4 - 20 mA electric signal and shall provide similar

trnasduced feedback output signal to control system. The minimum close-off rating

of actuator must be 1.5 times shut off head of pump as per specifications for the

following sizesa 20 mm dia No 17

Page 52: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b 25 mm dia No 8

c 32 mm dia No 6

d 40 mm dia No 6

3.5 Supply, Installation, testing & Commissioning of Proportional type thermostat

having 0-10V DC / 4-20mA output with Controller suitable to work with the above

valve or VFD input for AHU of approved make.

No 57

3.6Providing and fixing in position the following insulated Y-Strainers i/c all

accessories complete as required.

a 50 mm dia No 6

b 40 mm dia No 6

c 32 mm dia No 6

4 AIR DISTRIBUTION

a 0.63 mm (24 gauge) GSS Sqm 1000

b 0.8 mm (22 gauge) GSS Sqm 200

4.2

Supply, installation and testing of multiblade type louver damper of MS sheet for

Fresh air to be provided with suitable links, levers and quadrants for manual control

of volume of Fresh air flow as per approved shop floor drawings and specifications

complete as required..

Sqm 1

4.3

Supply, installation and testing of multiblade box type GSS construction

damper for ducts to be provided with suitable links and Supply, installation and

testing of multiblade box type GSS quadrants for control of volume of air.

Complete as required .

Sqm 15

4.4

Supply, installation, testing and commissioning of motorized combination fire

and smoke damper (spring return type) of approved make of atleast 90 minute fire

rating and as per the specifications as detailed earlier in the relevant sections. The

fire damper shall be complete with electronic temperature sensor and

electrically operated actuator. The fire dampers shall be located in the supply

/return air ducts at all fire rated crossovers (shaft/walls etc.) The control panel will

be such located that the reset can be easily done.These combination smoke and

fire dampers shall be interlocked withthe building management system for fire

detection / HVAC and shall trip/close in the event of fire / smoke in the respective

zone.(a+b++c)a Providing and fixing,Bare Fire Dampers with sleeve and fixing arrangement. Sqm 6

bProviding and fixing,Control panel actuator including Electrical spring type actuator

with smoke sensor and remote indication of the dire damper positionand control

wiring etc as required..

No 20

cInterconnecting wiring for the fire alarm system with the AHU and the smoke

dampersLot 20

4.5

Supply, installation, testing and commissioning of Fusible link type fire damper of

approved make of atleast 90 minute fire rating with Limit Switch and as per the

specifications as detailed earlier in the relevant sections for return air duct.(a+b+c)

a Bare Fire Dampers with sleeve and fixing arrangement Sqm 5

TOTAL CARRIED TO SUMMARY (PIPING) Rs

4.1

Supply, Fabrication, Installation and testing of sheet metal ducts in accordance

with the approved shop floor drawings and specifications and shall also

confirm to the ISI specifications

Page 53: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b Fusible link for fire damper No 18

c Interconnecting wiring for the Fire damper limit switch with AHU stater Lot 18

4.6

Supply, installation, testing and commissioning of square supply air diffusers as per

approved shop floor drawings and colour. Each diffuser will be equipped with

removable core and a aluminium volume control damper which will be key operated

complete as required.

aPowder coated extruded aluminium supply air diffuser with VCD of approved colour

and shade complete as required.Sqm 15

bPowder coated extruded aluminium supply air grill with VCD of approved colour and

shade complete as required.Sqm 4

4.7

Supply, installation, Testing and commissioning of Linear Grill for return air diffuser

as per approved shop floor drawings and colour. Each diffuser will be equipped with

removable core

aPowder coated extruded aluminium return air Grill of approved colour and

shadecomplete as required.Sqm 30

bPowder coated extruded aluminium return air diffuser/grill of approved colour and

shadecomplete as required.Sqm 6

5 INSULATION

5.1Supply and Application of accoustic lining within the supply air duct as per

specifications and drawings

a25 mm thick, 48 kg/m3 density FGP with 24G aluminium perforated sheet, tissue

paper as per specification etc as required.Sqm 126

5.2

Supply and Application of external thermal insulation of ducting with Self Adehisive

type Closed Cell Nitrial Rubber/FR XLPE with aluminium foil facia and of density

as specified in the specifications

a 19 mm thick for Supply air Sqm 1000

b 13 mm thick for Return air Sqm 150

5.3Supply, fixing and application of under deck insulation of roof exposed to direct

Sun with 25 mm Self Adhesiv type Close Cell Nitrial Rubber /FR XLPE with

necessary accessories complete as required..

Sqm 500

5.4 AHU Room WALL accostic Lining

a

Supply,installation,testing and commissioning of accoustion lining on all sides of

walls of each AHU room with fibreglass ,tissue paper and 24 gauge perforated

aluminium sheet.The fibre glass insulation shall be of 50 mmx32kg/m3 of board

type and shall be fixed on GI frame as per site condition and specification as

required.

Sqm 150

5.5Supply,installation,testing and commissioning of Inline Exhaust Fan complete as

required.

a 300 CFM No 5

6

TOTAL CARRIED TO SUMMARY (AIR DISTRIBUTION) Rs

TOTAL CARRIED TO SUMMARY (INSULATION) Rs

ELECTRICAL WORKS

Page 54: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

6.1

Design, fabrication, assembling, wiring, supply, installation, testing and

commissioning of following LT panels fabricated out of 14 gauge CRCA sheet

steel in cubical formation with reinforcement of suitable size angle iron and channel

T iron flats. All steel material used in the construction of panels shall undergo seven

tank process before painting as per standards with 2 coats of red oxide primer and

final approved shade of enamel paint. A solid busbar shall be provided at the

bottom of the panel with two connecting eyes for termination. The boards shall be

suitable for 415 volts, 50 Hz, 3 phase, 4 wire supply system. All the hardware used

in the fabrication of the panel shall be galvanized with zinc passivation. The panel

shall be compartmentalized to accomodate one feeder in eachcompartment.

A vertical cable alley of suitable width shall be provided to serve on or two

vertical feeder sections. Also the opening between the busbar chamber and the

feeder section shall be shrouded with bakelite/hylam sheet with mm 3 mm

thickness.All panels to have Auto Manual switches to make them compatible

Facility Management System (BMS).The panel drawing shall be approved before

taking up the fabrication.6.1.1

All panels to have Auto-Manual switches to make them compatible with Facility

Management System (BMS)

6.1.11 The panel drawing shall be approved before taking up the fabrication

a2 KW AHU stater panel with 2 KW VFD & DOL Bypass stater having MCCB as

incomer, phase indicating lamp, voltmeter, volt meter selecting switch,

semiconductor fuse for VFD, control fuse, 24V 50VA transformer for Fire damper

No 12

b

1 KW AHU stater panel with 1 KW VFD & DOL Bypass stater having MCCB as

incomer, phase indicating lamp, voltmeter, volt meter selecting switch,

semiconductor fuse for VFD, control fuse, 24V 50VA transformer for Fire damper

actuator & Dynamic balancing valve, toggle switch, start / Stop push button for

stater, power & Control terminals etc as per specification and of approved make.

(VFD will be supplied with Panel)

No 8

6.2 CABLING (POWER)

6.2.1 Power Cabling and Earthing

Electrical contractor but the terminations shall be done by the HVAC contractor

PVC insulation PVC sheathed armoured Aluminium FRLS cable of 1.1 kv grade

with termination glands and GI earthing identification tags, clamps, saddles etc.

a 3C x 6 sqmm RM 60

b 3C x 6 sqmm RM 40

6.2.2

aCopper conductor, PVC insulated PVC sheathed armoured FRLS cable of 1.1 kv

grade 2C x 1.5 sqmmRM 200

6.2.3 Cable Trays

6.2.31

P/F cable trays of ladder type made of GI slats 100 mm high and 2.6 mm thick

complete with clamps and suspension arrangement comprising of MS rods

(10 mm dia) etc. duly painted with Polyurethane plant.

a 100 mm wide RM 50

Control Cabling

TOTAL CARRIED OUT TO SUMMARY (ELECTRICAL)

SUMMARY

EQUIPMENT

Page 55: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

ELECTRICAL WORKS

TOTAL PART AC WORKS ,PART :E

PIPING

AIRDISTRIBUTION

INSULATION

Page 56: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1.0 PASSENGER LIFT :

1.1

Design, manufacture, supply, installation, testing & commissioning offollowing Passenger Lifts of 10 persons (680kg) capacity Gearless andmachine roomless, having minimum speed 1.0 m/sec., stainless steel body,automatic power operated center opening stainless steel power door withvision panel, Granite flooring finish, variable voltage and variable frequencydrive with microprocessor based Simplex full collective control, fitted withdirection & position indicator, emergency light & alarm bell, battery operatedemergency rescue device and infra-red door safety system as perspecification.

No. 1

Make : Shindler / Otis / Kone / Mistubishi / Jhonson (Subject to approval of

the dept. & subject to availability of service center at Guwahati).

a) 6 Stop, 6 Level, 6 Opening - (Ground to 5th floor).

TOTAL (PART - F : Passenger Lift)

PART - F : Passenger Lift

Name of Work : Construction of Centre for Educational Technology (CET) Building

Page 57: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1 CEMENT CONCRETE WORK

(a) Providing,vibrating, laying in position cement concrete of specified gradeincluding curing but excluding the cost of centring and shuttering in all worksupto floor-V level.

1:4:8 (1 cement : 4 coarse sand: 8 graded stone agg. 40 mm nominal size

Cum 41.00

(b) Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mmbed by dry brick ballast 40mm nominal size well rammed and consolidatedand grouted with fine sand including finshing the top smooth.

Sq.M. 206.25

2 STEEL REINFORCEMENT

Providing reinforcement for RCC work including straightening, cutting,bending, binding with specified wire & placing in position complete as perspecifications and drawings - Fe 500 D grade super ductile steel ofapproved manufacturer of all diameters as per relevent IS codes.

kilogram

233,870.01

3 CENTERING AND SHUTTERING

Providing, fitting and fixing of centring and shuttering including strutting,

PART - A : Building Works

Name of Work : Construction of Central Instruments Facility (CIF) Building

Providing, fitting and fixing of centring and shuttering including strutting,propping etc., & removal of forms at all heights and levels for concrete workto give desired surface finish on the concrete.

a Walls of any thickness including attached pilasters, buttress, plinth and string course etc. Sq.M. 3,065.20

b Suspended floors, roofs, inclined roofs and balconies / projections andchajjas, shelves. Sq.M. 4,100.50

c Lintels, beams, girders, bressummers & cantilevers including sloping beams.

Sq.M. 4,161.00

Page 58: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

d Column, pillars, posts & struts.

Sq.M. 2,068.00

e Staircase plain/folded plate including landings.

Sq.M. 132.00

f Small lintels not exceeding 1.5 m clear span, moulding as in cornices,window sills, string courses, bands, copings, bed plates, anchor blocks andthe like

Sq.M. 82.00

4 REINFORCED CEMENT CONCRETE

Providing and laying in position machine batched and machine mixed designmix M-25 grade cement concrete for reinforced cement concrete work, usingcement content as per approved design mix, including pumping ofconcrete to site of laying but excluding the cost of centering, shuttering,finishing and reinforcement, including admixtures in recommendedproportions as per IS: 9103 to accelerate, retard setting of concrete, improveworkability without impairing strength and durability as per direction ofEngineer-in-charge. All works at all heights and level.

a In lintels, beams, bressummers, suspended floors, roofs including inclinedroof, landings, balconies, chajjas, staircases etc. upto floor five level. Cum 1300.00

b In walls (of any thickness) including attached pillarsters, buttresses, plinthb In walls (of any thickness) including attached pillarsters, buttresses, plinthand string courses, fillets, column, pillars, piers, abutments posts and strutsetc. up to floor five level.

Cum 73.00

c Reinforced cement concrete work in vertical and horizontal fins individuallyor forming box louvers, facias and eaves boards up to floor five level,excluding the cost of centering, shuttering, finishing and reinforcement, with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mmnominal size).

Cum 25.00

d Providing, hoisting and fixing upto floor five level pre-cast reinforced cementconcrete in shelves including setting in cement mortar 1:3 ( 1 cement : 3coarse sand) cost of required centring, shuttering and finishing with neatcement punning on exposed surfaces but excluding the cost ofreinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5mm nominal size)

Cum 9.00

Page 59: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

5 MASONRY WORKS

a Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure : Cum 100.00

Cement mortar 1:4 (1 cement : 4 coarse sand)

b Providing and laying autoclaved aerated concrete (AAC) blocks masonrywith 100/150/200 mm thick AAC blocks in super structure above plinth levelup to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rateincludes providing placing in position 2 nos of 6mm dia MS bar at every thirdcoarse of masonry works.

Cum 1200.00

c Making circular opening for exhaust fan up to 600 mm dia in brick/AAC workby providing precast RCC ring of required diameter complete as directed byEngineer-in-Charge

Each 6

6 FLOORING

(a) 100 mm thick cement concrete in floors in proportion 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) over flat bricksoling with brick of designation 75 (to be measured and paid separately)including curing etc. complete as directed.

CUM 9.00

(b) 40mm thick cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with floating coat ofneat cement slurry in proper line and level.

Sq.M. 300.00

(c) Extra over item no.6(b) for finishing with NITOFLOR HARDTOP/equivalentof approved shade as per manufacturers specifications in place of floatingcoat of neat cement cement slurry complete as per drawing and as directed Sq.M. 300.00coat of neat cement cement slurry complete as per drawing and as directedby the Engineer-in -charge

Sq.M. 300.00

(d) Providing and laying flamed finish Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slab over20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with cement slurry and pointing with white cementslurry admixed with pigment of matching shade including rubbing, curing andpolishing etc. all complete as specified and as directed by the Engineerin-Charge :

Sq.M. 143.00

Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eyeor equivalent.

Page 60: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(e) Providing and fixing markana Chak doongri marble stone of averagethickness 18mm to 20mm over 20 mm thick base mortar of proportion 1:4 (1cement : 4 coarse sand) laid and jointed with tiles jointing compound ofmatching shade including half round moulding of the nose, rubbing andpolishing complete in all respects including cutting the stone to makenoutch/offset on all corners vertical and horizontal and moulding as pernoutch detail in drawing and directed in window sills.

Sq.M. 122.00

(f) Extra over item no. 6(e) for mirror polishing of marble stone surfaces.

Sq.M. 122.00

(g) Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc., including machine polishing to edge to give high gloss finishetc.complete as per design approved by Engineer-in-Charge.

Metre 258.00

Granite work

(h) Extra for providing opening of required size & shape for wash basins, kitchensink in kitchen platform, vanity counters and similar locations in mable/granite/ stone work including necessary holes for pillar tapes etc. includingrubbing and polishing of cut edges etc. complete.

Each 4

(i) Providing and fixing stone slab with table rubbed, edges rounded andpolished, of size 75 x 90 cm deep and 1.8 cm thick, fixed in urinal partitionsby cutting a chase of appropriate width with chase cutter and embedding thestone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per

Sq.M. 55.00: 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.

Granite Stone of approved shade mirror polished on both sides.

(j) 25 mm thick Kota stone slab flooring in steps over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment tomatch the shade of the slab, including rubbing and polishing complete withbase of cement mortar 1 : 4 (1 cement : 4 coarse sand) including mouldingof the nose complete as per Engineer-in-Charge :

Sq.M. 197.00

(k) Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laidon 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) andjointed with grey cement slurry mixed with pigment to match the shade of theslabs, including rubbing and polishing complete.

Sq.M. 125.00

Page 61: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(l) Providing and laying in floor Group -V matt finished ceramic tile of minimumthickness 7.8mm without warpage of approved design and manufacturerlaid on 20mm thick cement mortar 1:3(1cement:3 sand) including filling thejoints with pigmented tile joint filler Nitotile-GR or equivalent of matchingshade and approved manufacturer as per manufacturers specification etc.and cleaning the surface with detergent and water complete.Size 400 mm x 400mm.

Sq.M. 117.00

(m) Providing and laying in floor heavy duty vitrified antiskid matt finish tiles incorridors as per IS:4457 of minimum thickness 10mm without warpage ofapproved design and manufacturer laid on 20mm thick cement mortar1:3(1cement:4 sand) including filling the joints with pigmented tile joint fillerNitotile-GR or equivalent of matching shade and approved manufacturer asper manufacturers specification etc. and cleaning the surface with detergentand water complete. Size : 600 mm x 600 mm.

Sq.M. 1017.00

(o) Providing and laying vitrified tiles in floors and skirting in different sizes withwater absorption's less than 0.08% and conforming to IS: 15622 of approvedmake in all colours and shades,laid on 20mm thick cement mortar 1:3 (1cement : 3 coarse sand) including grouting the joints with approved tilejointing compound of matching colour etc.complete. Size 600 mm x 600 mm

Sq.M. 1945.00

(n) Providing and laying V.C shield Tiles of SOMANY / DURATUFF of ASEANTiles of 1st quality conforming to IS: 15622 of approved make in colours,shades, laid on 20mm thick cement mortar 1:3(1 cement : 3 coarse sand)including pointing the joints with tile jointing compounds of approvedmanufacturwer and matching shades etc. all complete (size 600mm X 600mm or more)

Sq.M. 450.00

mm or more)

7 DADO, SKIRTING, STEPS & RISERS

(a) Providing and laying Vitrified tiles in different sizes (thickness to be specifiedby manufacturer), with water absorption less than 0.08 % and conforming toI.S. 15622, of approved make, in all colours & shade, in skirting, riser ofsteps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarsesand), including grouting the joint with white cement & matching pigmentsetc. complete.

Sq.M. 135.00

Page 62: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(b) Providing and laying in steps, landings and risers heavy duty, vitrified,antiskid and matt finish tiles as per IS:4457 of minimum thickness 10mmwithout warpage of approved design and manufacturer laid on 20mm thickcement mortar 1:3(1cement:3 sand) including filling the joints withpigmented tile joint filler Nitotile-GR or equivalent of matching shade andapproved manufacturer as per manufacturers specification etc. andcleaning the surface with detergent and water complete Size: 600 mm x600mm

Sq.M. 131.00

(c) Providing and fixing ceramic tiles of approved design & shade and ofminimum thickness 5.6mm thick in dado/skirting in any pattern and size over12mm thick cement mortar 1:3(1cement : 3 coarse sand ) and filling thejoints with Nitotile-GR or equivalent of matching shade as per manufacturersspecification etc and cleaning the surface with detergent and watercomplete. Size-300mm x 600 mm

Sq.M. 304.00

8 DOORS AND WINDOWS

(a) Providing and fixing pressed steel door frames confirming to IS:4351manufactured from commercial mild sreel sheet of 1.6mm thicknessincluding hinges ,jamb,lock jamb,bead and if required angle threshold of mildsteel angle of section 50x25mm or base ties of 1.6mm pressed mild steelwelded or rigidly fixed together by mechanical means,adjustable lugs withsplit end tail to each jamb including steel but hinges 2.5mm thick with mortarguards,lock strike plate and shock absorber as specified and applying a coatof approved steel primer after ptre treatment of the surface as directed byEngineer-in Charge a) Profile-B

R.M. 380.00

(b) Providing and fixing ISI marked flush door shutters conforming to IS: 2202(Part) decorative, core of block construction with frame of 1st class hardwood and well matched teak 3 ply veneering with vertical grains or crossbands and face vanees on both faces of shutters. 30mm thick including ISImarked Stainless Steel built hinges with necessary screws.

Sq.M. 83.00

(c) Providing and fixing ISI marked flush door shutters conforming to IS : 2202(Part I) non-decorative type, core of block board construction with frame of1st class hard wood and well matched commercial 3 ply veneering withvertical grains or cross bands and face veneers on both faces of shutters:

Page 63: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

30 mm thick including ISI marked Stainless Steel butt hinges with necessaryscrews Sq.M. 59.00

(d) Providing and fixing glazing in doors, windows and ventilators shutterscompete as per architectural drawings and the directions of Engineer-in–charge.

With clear glass panes of 5.0 mm thickness (weight not less than 13.75kg/sqm) Sq.M. 350.00

(e) With float glass panes of 8 mm thickness

Sq.M. 392.00

(f) With frosted glass panes of 5.0 mm thickness (weight not less than13.75kg/sqm) Sq.M. 14.00

9 ALUMINIUM WINDOWS

(a) Providing and fixing 50 micron powder coated aluminium work for doors,windows(catchment/sliding), ventilators, partitions or any other places withextruded built up standard tubular and other sections of approved makeconfirming to IS:733 and IS: 1285, fixed with rawl plugs and screws or withfixing clips, or with expansion hold fasteners including necessary filling up ofgaps at junction, at top, bottom and sides with required PVC/ neoprene felt,silicon sealants etc. to make perfactly watertight. Aluminium sections shallbe smooth , rust free, straight, and jointed mechanically wherever requiredbe smooth , rust free, straight, and jointed mechanically wherever requiredincluding cleat angle, aluminium snap beading for glazing/ panelling, C.P./stainless steel screws, hinges all complete as per architectural drawings andthe directions of Engineer-in-Charge. (Glazing and panelling shall be paidseparately)

oAluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminium snapbeading for glazing / paneling, C.P. brass / stainless steel screws, allcomplete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

For fixed portions like outer frames etc

kg 3481.00

Page 64: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(b) For shutters of doors, windows & ventilators including providing and fixinghinges/ pivots and making provision for fixing of fittings wherever requiredincluding the cost of EPDM rubber / neoprene gasket required (Fittings shallbe paid for separately)

kg 3089.00

Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron)

(c) Providing and fixing of double action heavy duty Hydraulic door spring ofapproved make (hardwyn or equivalent) Each 52

(d) Providing and fixing 12mm prelaminated three layer medium density(exteriorgrade) particle board Grade-I, type-II conforming to IS:12823 bonded withphenol formaldehyde synthetic resin of approved brand and manufacturer inpanelling fixed in aluminium door shutter with C.P./ Brass/ stainless steelscrews etc. complete as per Architectural drawings and the direction ofEngineer-in-charge

Sq.M. 890.00

10 PARTITIONS AND FALSE CEILING WORKS

(a) Providing and fixing 6mm thick hollow PVC strips and other accessories ofapproved colour in the frame work made of special sections power pressedfrom M.S. sheet and galvanized in accordance with zinc coating 600 as perIS: 277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick withflanges of 22 mm and 37 mm at 1200 mm centre to centre one flange fixedto the ceiling with dash fastener 12.5 mm dia x 40 mm long with dashfastener 12.5 mm dia x 40 mm long with 6mm dia bolts to the angle hangersof 25 x 25 x 5 mm of required length , and other end of angle hanger being Sq.M. 3050.00of 25 x 25 x 5 mm of required length , and other end of angle hanger beingfixed with nut and bolts to G.I channels 45 x 15 x 0.9 mm running at the rateof 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottomwedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5mm at 450 , maintaining the descried profile ( horizontal / vertical / slanting /arch ) as per drawing all complete as per drawing and specification anddirection of the engineer – in charge

Sq.M. 3050.00

Page 65: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(b) 98mm thick metal stud partition which includes one layer of tapered edge13mm thick DURALINE gypboard of India gypsum or equivalent (confirmingto IS:2095-1982) screw fixed with drywall screws of 25mm at 300mm centresto either sides of 70mm studs (0.55mm thick having one flange of 34mm &another flange of 36mm made GI steel) placed at 610mm centre to centre in72mm floor and ceiling channel (0.55mm thick having equal flanges of 32mm made GI steel) with joints staggered to avoid leakage through joints. Finallythe square and tapered edges of the boards are to be joined and finished soas to have a flush look which includes filling and finishing with jointingcompound. Joint paper tape and two coats of drywall top coat suitable forgypboard including angle bead to be at external angles to get straight linefinish & protection from normal impacts and edge bead to be used to protectthe exposed gypsum core of gypboard specially at cut edges of the openingfor doors/ windows/ glazig or any other unprotected core complete as per thedrawing & direction of engineer-in-charge (as per recommended practices ofIndia gypsum)

Sq.M. 575.00

11 STEEL WORK

Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc. including priming coat withapproved steel primer all complete.

a) Fixed to openings /wooden frames with rawl plugs screws etc.

Kg 4935.00

b) Steel work in built up tubular trusses including cutting , welding hoistingfixing in position and applying a coat of yellow zinc chromate primer welded

Kg 1874.00fixing in position and applying a coat of yellow zinc chromate primer weldedand bolted including special shaped washers complete a) Hot finishedwelded type tubes

Kg 1874.00

c) Providing and fixing bolts including nuts and washers complete.

Kg 302.00

Page 66: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

d) Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete, i/c fixing the railing withnecessary accessories & stainless steel dash fasteners , stainless steelbolts etc., of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, ( forpayment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.).

Kg 4270.00

e) Providing, fabrication and fixing of structural glazing made out of colouredanodised aluminium mother frame (INDAL 9303) and subframe (INDAL9406)and 5mm reflective glass of approved shade. The glass to be pasted usingstructural silicon (DC995) and weatherseal silicon to be used (DC789), thestructure complete with all accessories as and where necessary.

Sq.M. 75.00

12 TERRACING

(a) Providing and fixing on wall face unplasticised Rigid PVC rain water pipesconforming to IS : 13592 Type A,including jointing with seal ring conformingto IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketedpipes.

Metre 578.00

110 mm diameter

(b) Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10 mm gap for thermal expansion.

Coupler Coupler

110 mm

Each 289

( c ) Bend 87.5°

110 mm bend Each 34

(d) Shoe (Plain)

110 mm Shoe Each 34

Page 67: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

( e) Providing and fixing unplasticised -PVC pipe clips of approved design tounplasticised - PVC rain water pipes by means of 50x50x50 mm hard woodplugs, screwed with M.S. screws of required length, including cutting brickwork and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and makinggood the wall etc. complete.

Each 289

110 mm

( f) Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 stone aggregate 10 mm and down gauge), including finishing withcement mortar 1:3 (1 cement : 3 fine sand) as per standard design : Metre 291.00

In 75x75 mm deep chase

( g) Making khurras 45x45 cm with average minimum thickness of 5 cm cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neatcement, rounding the edges and making and finishing the outlet complete.

Each 34

(h) Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15cm diameter and weighing not less than 440 grams. Each 34

(i) Providing & Fixing of 12mm thick UV protected polycarbonate panels withopaque & Transluscent combination for aesthetic appeal with verticalstanding seam on both sides, snap on locking system. The system will befitted on MS rafters/Purlin (will be paid separately) with spacing as specified

Sq.M. 126.00fitted on MS rafters/Purlin (will be paid separately) with spacing as specifiedby manufacturer.

13 WATER PROFFING

(a) Providing water proofing treatment with best quality acrylic polymer modifiedcementitious composite slurry quoating and fibre glass cloth of approvedbrand over sunken floors roof and terraces as per manufacturer'sspecification and as approved by Engineer-in-Charge.

Sq.M. 163.00

Page 68: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

(b) Providing and laying water proofing treatment on roofs of slabs by applyingcement slurry mixed with water proofing cement compound consisting ofapplying: a) after surface preparation, first layer of slurry of cement @ 0.488kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. b)laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layerof 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixedwith water proofing cement compound @ 0.670 kg/sqm and coarse sand @1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by watercuring for 48 hours. The entire treatment will be taken upto 30 cm on parapetwall and tucked into groove in parapet all around. d) fourth and final layer ofbrick tiling with cement mortar (which will be paid for separately. For thepurpose of measurement the entire treated surface will be measured.

Sq.M. 2230.00

Grading roof for water proofing treatment with

(c) Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) Cum 323.10

(d) Providing 12mm thick plaster to protect waterproofing treatment in cementmortar 1:4 ( 1cement : 4 coarse sand) . Sq.M. 105.00

14 FINISHING

( a ) 12 mm thick cement plaster on even surface of wall with cement mortar 1:4(1 cement : 4 sand)

Sq.M. 17317.00

(b) 15 mm thick cement plaster on the rough side of single or half brick wall withcement mortar of 1:4 (1 cement : 4 sand)

Sq.M. 4885.00

( c ) 6 mm plaster to ceiling in cement mortar 1:3 (1 cement : 3 sand) Sq.M. 4212.00

( d ) Neat cement punning. Sq.M. 25.00

Page 69: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

( e) Providing and applying wall care putty of Birla White/JK white or equivalentat all heights and levels on the entire surface including removal ofundulations and sand papering the wall after the surface is dry to get asmooth and even surface

Sqm 22202.00

( f) Providing and applying cement primer of approved manufacturers overprepared surface: Sq.M. 22202.00

( g ) Finishing walls with textured exterior paint of required shade

New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and includingpriming coat of exterior primer applied @ 2.20kg/ 10 sqm Sq.M. 245.00

(h) Finishing walls with fungus and algae resistant superior grade water proofacrylic paint of approved shade and brand to give an even shade to allexternal wall surfaces(two or more coats) including surface preparation togive an even surface as per manufacturer's specification

Sq.M. 4906.00

Applying priming coat :

( i ) With ready mixed pink or Grey primer of approved brand and manufactureon wood work (hard and soft wood) Sq.M. 295.00

( j) With ready mixed yellow zinc chromate primer of approved brand andmanufacture on steel galvanised iron/ steel works Sq.M. 472.00

( k) Painting with synthetic enamel paint of approved brand and manufacture to( k) Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Sq.M. 767.00

Two or more coats on new work

( l ) Providing and applying on walls two or more coats of Acrylic emulsion ofapproved shades and manufacturer. Sq.M. 17317.00

(m) Providing and applying on walls and ceiling two or more coats of Acrylicwashable distemper of approved shades and manufacturer. Sq.M. 4212.00

Page 70: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

15 BUILDING HARDWARE

(a) Providing and fixing aluminium sliding door bolts, ISI marked anodisedanodic coating not less than grade AC 10 as per IS : 1868), transparent ordyed to required colour or shade, with nuts and screws etc. complete : -300x16mm.

Each 140

(b Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed torequired colour or shade, with necessary screws etc. complete 300x10mmsize.

Each 188

(c) Providing and fixing aluminium handles ISI marked coloured anodised(anodic coating not less than grade AC 10 as per IS:1868) of approvedcolour or shade wiith necessary screws etc. complete: 125mm.

Each 188

(d) Providing and fixing aluminium hanging floor door stopper ISI markedanodised (anodic coating not less than grade AC 10 as per IS: 1868transparent or dyed to require colour and shade with necessary screws etc.complete.

i) Single rubber stopper

Each 56

ii) Twin rubber stopper

Each 52

(e) Providing and fixing aluminium round shape handle of outer dia 100 mm withSS screws etc. complete as per direction of Engineerin-chargeSS screws etc. complete as per direction of Engineerin-charge

Polyester powder coated minimum thickness 50 micronaluminium Each 108

16 DISMANTALING WORK

( a ) Demolishing cement concrete manually/ by mechanical means includingdisposal of material within the IITG campus as per direction of Engineer - in -charge.

Cum 15.00

(b) Demolishing R.C.C. work manually/ by mechanical means including stackingof steel bars and disposal of unserviceable material within the IITG Campusas per direction of Engineer - in- charge.

Cum 35.00

Page 71: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

( c ) Demolishing brick work manually/ by mechanical means including stackingof serviceable material and disposal of unserviceable material within theIITG Campus as per direction of Engineer-in-charge.

Cum 63.50

( d) Dismantling roofing including ridges, hips, valleys and gutters etc.,andstacking the material within the IITG Campus of G.S. Sheet. : Sq.M. 239.00

17 MISCELLANEOUS ITEMS

PARTITIONS AND ASSOCIATED WORKS

Toilet Cubical

( a ) Providing & fixing Greenlam Sturdo Classique Versatile Toilet Cubicle (offollowing standard dimension which includes 600mm door size width) madeof heat,bacteria, water, chemical, scratch, impact and anti bacterial resistant12mm thick solid compact laminate panels tested by Shriram Test House.Finish of the compact laminate should be Suede, which includs doors,pilasters & intermediate panels finished with approved texture/shade as perthe detail drawings & as per IS 2046 (Indian Standard) and as per fireretardant BS-476/97 standard. The product should have Green GuardCertificate.This also includes providing and fixing in position necessary hardware madeout of Stainless steel (Grade 304) &

No. 8

Aluminium powder coated top rail as per manufacturer’s specifications &Architects instructions like (1) SS Door Knob, (2) SS Gravity hinges, (3) SSThumb turn lockset indicators, (4) Aluminum Powder Coated Top Rail, (5)SS Coat Hooks, (6) SS U-Channels, (7) SS Adjustable Foot, (8) NoiseSS Coat Hooks, (6) SS U-Channels, (7) SS Adjustable Foot, (8) NoiseDeafening Tape etc. (9) Screws & wall Plugs.The top fitting should consist ofAluminium Powder Coated top rail which will get fixed with Mid & Endpilasters. All other hardware & screws will of stainless steel in 304 Grade with satinfinish. Top rail is extruded Aluminium will be powder coated or anodized(Grade 6063 Micron Aluminium). All pilasters are supported by stainlesssteel adjustable footing with non corrosive steel inserts.

Toilet Cubicle with standard dimension of 1955mm Height x 1000mm Widthx 1550mm Depth, which includes 600mm door size width).

Toilet Cubicle I-Shape (Front Partition) with standard dimension of 1955mmHeight x 1000mm Width which includes 600mm door size width).

Page 72: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

All aspects specified by the manufactures, Greenlam Sturdo ClassiqueVersatile Model or equivalent.

(b) Under Deck (Roof) Insulation:SINGLE LAYER SYSTEM UNDER DECKTHERMAL INSULATION SYSTEM WITH INSU.BOARD Sq.M. 1700.00

Cleaning of the surface by brush

(c) Day Time use Building: Providing & Laying of Insuboard, thickness 50mm ofdensity 32 kgs/ cum over the RCC CEILING ( Plastered Surface) frominside. The insuboard will be fixed over the wall surface by the PVC Fastner(side lap) (Make: M/S Supreme or equivalent)

Sq.M. 1700.00

. TOTAL (PART - A : Building Works)

Page 73: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1 Providing and fixing white vitreous china pedestal / wall hung type watercloset (European type W.C. pan) with seat and lid, 10 litre low level whiteP.V.C.flushing cistern, including flush pipe, with manually controlled device(handle lever), conforming to IS : 7231, with all fittings and fixtures complete,including cutting and making good the walls and floors wherever required :

W.C. pan with ISI marked white solid plastic seat and lid

Each 10

2 Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.

Semi rigid pipe

32 mm dia Each 10

3 Providing and fixing white vitreous china flat back half stall urinal of size580x380x350 mm with electrically operated concealed electronics flushingsystem and standard size C.P. brass flush pipe, spreaders with unions andclamps (all in C.P. brass) witrh waste fitting as per IS : 2556, C.I. trap withoutlet grating and other couplings in C.P. brass including painting of fittings

Each 10

PART - B : Sanitary and Water Supply Installation

Name of Work : Construction of Central Instruments Facility (CIF) Building

outlet grating and other couplings in C.P. brass including painting of fittingsand cutting and making good the walls and floors wherever required.

4 Providing and fixing 600x450 mm beveled edge mirror of superior glass(ofapproved quality) complete with 6 mm thick hard board ground fixed towooden cleats with C.P. brass screws and washers complete.

Each. 10

5 Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets andguard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.

Each 10

6 Providing and fixing toilet paper holder :

Page 74: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

C.P. brass Each 10

7 Providing and fixing PTMT Bottle Trap for Wash basin and sink.

Bottle trap 31mm single piece moulded with height of 270 mm,effective length of tail pipe 260 mm from the centre of the wastecoupling, 77 mm breadth with 25 mm minimum water seal,weighing not less than 260 gms

Each 10

8 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including paintingof fittings and brackets, cutting and making good the walls wherever required:

Each 5

Kitchen sink with drain board

510x1040 mm bowl depth 250 mm

9 Providing and fixing white vitreous china laboratory sink with C.I. brackets,C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P.brass trap with necessary C.P. brass unions complete, including painting offittings and brackets, cutting and making good the wall wherever required :

Each 3

Size 600x450x200 mm

10 Providing and fixing PTMT towel rail complete with brackets fixed to woodencleats with CP brass screws with concealed fittings arrangement ofapproved quality and colour.

600 mm long towel rail with total length of 645 mm, width 78mm andeffective height of 88 mm, weighing not less than 190 gms Each 10effective height of 88 mm, weighing not less than 190 gms Each 10

PP- R PIPES

11 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesSDR 7.4, U V stabilized & anti - microbial fusion welded, having thermalstability for hot & cold water supply, including all PP - R plain & brassthreaded polypropylene random fittings, i/c fixing the pipe with clamps at1.00 m spacing. This includes testing of joints complete as per direction ofEngineer in Charge.

Internal work - Exposed on wall

18.4.3 PN - 16 Pipe, 25 mm OD

Metre 100.00

Page 75: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

18.4.4 PN - 16 Pipe, 32 mm OD

Metre 130.00

18.4.5 PN - 16 Pipe, 40 mm OD

Metre 75.00

12 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipesSDR 7.4, U V stabilized & anti - microbial fusion welded, having thermalstability for hot & cold water supply, including all PP - R plain & brassthreaded polypropylene random fittings, i/c fixing the pipe with clamps at1.00 m spacing. This includes the cost of cutting chases and making goodthe same including testing of joints complete as per direction of Engineer inCharge.

Concealed work, including cutting chases and making good the walls

etc.,

18.5.1 PN - 16 Pipe, 16 mm OD

Metre 155

18.5.2 PN - 16 Pipe, 20 mm OD

Metre 145

BRASS FITTINGS

13 Providing and fixing brass bib cock of approved quality :13 Providing and fixing brass bib cock of approved quality :

15 mm nominal bore

Each 20

14 Providing and fixing brass stop cock of approved quality :

15 mm nominal bore

Each 36

15 Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete :

15 mm nominal bore

Each 2

Page 76: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

16 Providing and fixing uplasticised PVC connection pipe with brass unions :

45 cm length

15 mm nominal bore

Each 25

17 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipesbut without fittings and the base support for tank.

per litre

2000

18 Supplying and fitting fixing C.P. pillar cock of 15mm dia of 5011 of Jaquarbrand as specified and directed. Each 15

19 Providing fitting and fixing C.P. Grating to the floors complete as directedand specified. Each 30

a) 100mm dia

20 Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms.

Each 10

PVC PIPES,BENDS,JUNCTIONS,TEES ETC.

21 Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) orother ISI approved including joining ,fitting and fixing with clamps etc.asnecessary complete at all levels including below G.L as directed andnecessary complete at all levels including below G.L as directed andspecified.

a) In exposed surfaces or in trenches.

i) 110 mm dia Metre 89.00

ii) 75 mm diameter : Metre 89.00

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

Page 77: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

i) 110 mm dia Metre 55.00

ii) 75 mm diameter : Metre 42.00

22 Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) orother ISI approved including joining ,fitting and fixing etc.as necessarycomplete at all levels including below G.L as directed and specified.

a) In exposed surfaces or in trenches.

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 15

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

i) 110 mm dia Each 8

ii) 75 mm diameter : Each 10

23 Supplying fiting and fixing 87.5 degree PVC bend with door of(Supreme/Prince) or other ISI approved including joining , fitting and fixingetc. as necessary complete at all levels including below G.L. as directed andspecified.

a) In exposed surfaces or in trenches.

i) 110 mm dia Each 10

Page 78: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

ii) 75 mm diameter : Each 8

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 10

24Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) orother ISI approved including joining , fitting and fixing etc. as necessarycomplete at all levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 8

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makingb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 8

25Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or otherISI approved including joining, fitting and fixing etc. as necessary completeat all levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

Page 79: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 10

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

i) 110 mm dia Each 8

ii) 75 mm diameter : Each 8

26Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) orother ISI approved including joining , fitting and fixing etc. as necessarycomplete at all levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

i) 110 mm dia Each 8

ii) 75 mm diameter : Each 8

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

i) 110 mm dia Each 8

ii) 75 mm diameter : Each 8

Page 80: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

27Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISIapproved including joining , fitting and fixing etc. as necessary complete atall levels including below G.L. as directed and specified.

a) In exposed surfaces or in trenches.

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 10

b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and makinggood to the damages.

i) 110 mm dia Each 10

ii) 75 mm diameter : Each 10

28 Providing vitreous China wash basin with CI/MS brackets, C.P brass chainwith plug,PVC waste pipe including painting of fittings and brackets, cuttingand making good the walls wherever required. (Pillar cock, stop cocks,waste coupling are to be paid separately)

(a) White(a) White

(i) Optra 570 x 440 (Cat. No.91008)

Each 10

29 Providing and fixing of Health faucet CAT NO. ALDCHR-579

Each 10

TOTAL (PART - B : Sanitary and Water Supply Installation)

Page 81: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

Sl.

No.Item Description Unit Qty.

Rate in Figure

(Rs.)Rate in Words

Amount

(Rs.)

1.0 POINT WIRING AND SUBMAIN WIRING

1.1

Wiring for light point / fan point / exhaust fan point / call bell point with 1.5sq.mm. PVC insulated, FR, multistrand copper conductor cable in surface/recessed medium class PVC conduit complete with modular switch, modularplate, suitable G.I. box and earthing the point with 1.5 sq.mm, FR PVC insulatedcoper conductor single core cable etc., as required..

Point 520

1.2

Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copperconductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with1.5 sq.mm FR PVC insulated copper conductor single core cable etc. asrequired.

Point 10

1.3Wiring for submain with the following sizes of PVC insulated, FR copperconductor, single core cable in surface/recessed PVC conduit, as required.

a) 3 X 1.5 sq.mm Mtr. 650

b) 3 X 2.5 sq.mm Mtr. 1500

PART - C : Electrical Works

Name of Work : Construction of Central Instruments Facility (CIF) Building

b) 3 X 2.5 sq.mm Mtr. 1500

c) 3 X 4 sq.mm Mtr. 22000

d) 3 X 6 sq.mm Mtr. 1500

e) 6 X 4 sq.mm Mtr. 1500

Page 82: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

f) 6 X 2.5 sq.mm Mtr. 1100

g) 6 X 6 sq.mm Mtr. 650

h) 2 X 10 sq.mm + 1 X 6 sq.mm earth wire Mtr. 450

i) 4 X 10 sq.mm + 2 X 6 sq.mm earth wire Mtr. 1800

j) 4 X 16 sq.mm + 2 X 6 sq.mm earth wire Mtr. 1700

1.4

Supplying and fixing metal box of 150mm X 75mm X 60mm deep (normal size)in recess with suitable size pheno;ic laminated sheet cover in the front includingproviding and fixing of one 5 pin 5/6amps socket outlet and one 5/6amps pianotype switch. connections painting etc., as per required. (for light plugs).

No. 250

1.5

Supplying and fixing metal box of 180mm X 100mm X 60mm deep (normal size)in recess with suitable size phenolic laminated sheet cover in the front includingproviding and fixing one 6 pin 15/16 Amp. socket & 15/16 Amp. piano type

No. 2801.5providing and fixing one 6 pin 15/16 Amp. socket & 15/16 Amp. piano typeswitch, connections, painting etc., as required (for power plugs)

No. 280

1.6

Supplying and fixing metal box of 200 mm x 150 mm x 60 mm deep (nominalsize) on surface or in recessed with suitable size of phenolic laminated sheetcover in the front including providing & fixing 3 nos. 5 pin 6 Amp socket outletand 1 no. 16 Amp piano type switch connection painting ect., as required. (forComputer Power Point)

No. 410

1.7 Supplying & fixing of following switchs in existing box

a) 6A piano type switch No. 270

Page 83: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

b) 16A Piano switch No. 620

1.8 Supply & fixing of following sockets in existing box

a) 6A socket No. 920

b) 16A socket No. 600

1.9Supplying and fixing in RCC slab before concreting M.S. sheet hexagonal fanhook box of approximately 150mm dia and covering with suitable of phenoliclamitad sheet cover with brass screws, as required.

No. 2

1.10Supplying, fixing of following M.S. boxes complete with phenolic laminatedsheet cover, including painting etc. complete.

a) 180mm X 100mm X 60mm No. 450

b) 200mm X 150mm X 60mm No. 260

c) 200mm X 250mm X 60mm No. 180

1.11 Supplying & installation of electronic step regulator in existing switch box No. 29

1.12Supply & installation including connection to existing wiring etc. of followingpresence detectors / movement detector -

a) Single lens, 360°, 6 m dia detector, 10A, AC, 1 Channel surface / flushmounted for corridor / toilet - Cat.- Hager - EE804 / 805 or equivalent.

No. 45

Page 84: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

2.0 CABLING

2.1 Supplying of following PVC/XLPE insulated cable 1.1 KV grade

a) 3.5 C 240 sq.mm Mtr. 100

b) 3.5 C 185 sq.mm Mtr. 80

c) 4 C 25 sq.mm Mtr. 100

2.2Laying of one number PVC/XPLE insulated and sheated 1.1KV gradeAluminium armouredpower cable of following size in duct pipe/trench etc.

a) above 95 sq.mm and upto 185 sq mm Mtr. 50

b) above 185 sq.mm and upto 400 sq mm Mtr. 100

c) Upto 35 sq.mm Mtr. 100

2.3Supplying and making end termination with brass compression gland andaluminioum lig the following size of PVC/XLPE insulated conductor cable of1.1KV grade, as required.

a) 3½ C 240 sq.mm Set 4

b) 3½ C 185 sq.mm Set 6

Page 85: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

c) 4 C 25 sq.mm Set 6

3.0 DISTRUBTION BOARDS / MV PANEL

3.1Supplying and fixing of miniature circuit breaker with 'C' curve, 10 KA offollowing poles in the existing MCB DB complete with connections, testing andcommissioning etc., as required (5-32A).

a) Single pole No. 704

b) Double pole No. 16

c) Triple pole No. 40

d) Triple pole & netural No. 32

3.2Supplying and fixing single pole, blanking plate in the existing MCB DBcomplete etc. as required.

No. 30

Supplying and fixing 20amps, 240 volts, SPN industrial type, socket outlet, with

3.3

Supplying and fixing 20amps, 240 volts, SPN industrial type, socket outlet, with2 pole and earth, metal enclosed plug top along with 20amps C-series, SP,MCB in sheet steel enclosure, on surface or in recess, with chained metal coverfor the socket outlet, and complete with connections, testing and commissioningetc. as required.

No. 50

3.4

Supplying and fixing 30amps, TPN industrial type socket outlet, with 4 pole andearth, metal enclosed plug top along with 30amps "C' series TP MCB in sheetenclosure, on surface or in recess, with chained metal cover for the socketoutlet and complete with connection, testing, commissioning as required.

No. 35

Page 86: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

3.5

Supplying and fixing of following way single pole and netural, steel, dustprotected double door type MCB distribution board 240 volts, onsurfacew/racess complete with loose wire box, terminal blocks, tinned copperbusbar, neutral link, earth bar, din bar, detachable gland plate, inter-connections, including power coated painting,earthing etc., as required.

a) 8 way, Double door No. 8

b) 12 way, Double door No. 8

3.6

Supplying, installation, testing and commissioning of surface/recess mounting,horizontal type, double door 415 volts, TPN MCB distrubtionboard of sheetsteel, 1.6 mm thick, dust protected, duly phosphatized and painted, inclusive of200amps tinned copper busbars, earth bar, common neutral link, din bar formounting MCB's detachable gland/knock out plates, hinged front acrylic coerand with built in loose wire box, and superior make terminal connectiors for allincoming and outgoing circuits, duly prewired with adequate size of PVCinsulated copper wires between the busbars and the MCB's as well as theincomer and upto the terminal connectors/neutral link and ready for installation,of followin ways (but without the supply of outgoing MCB's/Isolator)

a) 6 way (4+18), Double door No. 16a) 6 way (4+18), Double door No. 16

3.7

Supplying, installation, testing and commissioning of surface/recess mounting,vertical type, double door, 415 volts, TPN MCB distrubtion board of sheet steel,1.6 mm thick, dust protected, duly phosphatized and painted, inclusive of200amps tinned copper busbars, earth bar, common neutral link, din bar formounting MCB's detachable gland/knock out plates, hinged front acrylic coverand with built in loose wire bix, and superior make terminal connectiors for allincoming and outgoing circuits, duly prewired with adequate size of PVCinsulated copper wires between the busbars and the MCB's as well as theincomer and upto the terminal connectors/neutral link and ready for installation,of following ways complete with supply of one 100A, 16 KA, TP MCCB at theincomer (but without the supply of outgoing MCBs)

Page 87: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

a) 8 way (4+24), Double door No. 20

3.8

Fabrication, supplying, installation, testing & commissioning of wall/floormounted cubicle board out of 2mm thick CRCA MS sheet steel, havingmountings as detailed below in suitable size compartments, lockingarrangement for each compartment including interconnection with 1100V gradePVC insulated copper conductor of size as that of sunmains, labelling, earthing,brass compression glands for incoming and outgoing cables and suitableadapter box for outgoing submains:

a) MDB-1

Incomer: No. 1

400A TP MCCB, 50KA breaking capacity having 70%-100% adjustment thermalseeting -1 No.

1 set digital multifunction meter for measurement of current, voltage, KWh,KVAh & p.f. current Transformer, Selector Switches including Lamps at theincoming.

Bus Bar:

400A 4 Strip Aluminioum Bus Bar

Outgoing:

200A TP MCCB, 35KA breaking capacity- 4 No.

100A TP MCCB, 25KA breaking capacity -10 Nos.

63A TP MCCB, 25KA breaking capacity -6 Nos.

32A DP MCB - 10 Nos.32A DP MCB - 10 Nos.

b) SDB-1

Incomer: No. 2

200A TP MCCB, 35KA breaking capacity having 70%-100% adjustable thermalseeting - 1 No.

1 Set digital multifunction meter for measurement of current, voltage, KWh,KVAh & p.f., current Transformer, Selector Switches indicating Lammps at theincoming.

Bus Bar:

200A 4 Strip Aluminioum Bus Bar

Outgoing:

100A TP MCCB, 25KA breaking capacity - 10 Nos.

63A TP MCCB, 25KA breaking capacity - 6 Nos.

32A DP MCB - 6 Nos.

Page 88: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

4.0 LIGHTING FIXTURE & FANS

4.1Installation, testing and commissoning of wall bracket / ceiling fittings of all sizesof LED fittings on ceiling/wall recessed or surface including connections with 1.5sq.mm PVC insulated, copper conductor, single core cable etc., as required.

No. 450

4.2Installation of exhust fan upto 450mm sweep in the existing opening, includingmaking the hole to suit the size of the above fan, making good the damage,connections, testing, commissioning etc., as required.

No. 30

4.3Supply of following light fittngs (LED) complete with all accessories such asholders, copper/HF ballast, wherever required, etc. complete factory wired witcopper conductor and lamp as required.

(i) RC 380B G2 LED 35S-6500 PSU OD WH - 2 x 2 square LED recessed fittingof Philips

No. 200

(ii) BN 150W LED 20S-6500 PSE OD GR - LED batten of Philips. No. 50

(iii) DN192B LED 9S-6500 PSU WH SI round LED recessed light of Philips No. 200

Equivalent fittings from Philips / Crompton / Wipro / Syska / Havells may beused subject to approval. All LED fittings shall have 5 years warranty from themanufacturer w.e.f from the date of supply.manufacturer w.e.f from the date of supply.

4.4 Supply of following heavy duty Exhaust fans with louvers

a) 300mm sweep No. 6

5.0 EARTHING AND LIGHTNING PROTECTION

5.1Earthing with G.I. earth pipe 4.5m long X 40mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. ( with charcoal or coke and salt) complete, as required.

Set 4

5.2

Earthing with G.I. earth plate 600mm X 600mm X 6mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and waterting pipe etc. (with charcoal or coke and salt) complete,as required.

Set 4

Page 89: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

5.3Supplying and laying 25mm X 5mm G.I. strip at 0.50m below ground level asstrip earth electrode, including soldering etc., as required.

Mtr. 80

5.4Providing and fixing 25mm X 5mm G.I. strip in 40mm dia G.I. pipe from the earthelectrode, as required.

Mtr. 15

5.5Providing and fixing 25mm X 5mm G.I. strip on surface or in recess forconnections etc., as required

Mtr. 200

5.6Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loopearthing along with the existing surface/recessed conduit/submain wiring/cableas required

Mtr. 30

5.7Providing and fixing of lightning conductor final made of 25mm dia, 300mm longG.I. tube, having single prong at top, with 85mm dia 6mm thick G.I. plateincluding holes etc., as required.

No. 8

5.8Revetting, sweating and soldering of copper/G.I. tape (with another copper/G.I>tape, base of the finial or any other metalic object) as required.

No. 80

5.9Providing and fixing G.I. tape 20mm X 3mm thick on parapet on surface of wallfor lighting conductor as required. (for horizontal run)

Mtr. 250

5.10Providing and fixing G.I. tape 20mm X 3mm thick on parapet or surface of wallfor lighting conductor as required. (for vertical run)

Mtr. 160

5.11Providing and fixing testing joint, made of 20mm X 3mm thick G.I. strip, 125mmlong, with 4 nos. of G.I. bolts, nuts, check nuts and spring washers etc.complete as required.

No. 8

6.0 WIRING FOR TELEPHONE

6.1Wiring for telephone points/tag blocks/call indicator units with following sizePVC insulated annealed tinned electrolytic copper conductor cable in existingrecessed conduits, ducts, shafts etc. (cost includes supply of wires)

Page 90: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

a) 0.5 mm dia 2 pair Mtr. 2100

6.2Providing and fixing in posotion telephone junction box complete with hingeddoor having locking arrangement with following tag blocks.

a) 50 pair tag block No. 1

b) 20 pair tag block No. 2

6.3Supplying and fixing of 2 pin Telephone jack RJ-11 modualr type in compatiablebox along with cover plate etc. complete

No. 60

6.4Supplying and fixing of following size of PVC conduit along with the acessoriesin surface/recess incuding painting in case of surface conduit, or cutting the wallmaking good the same in case of recessed conduit as required.

a) 20 mm Mtr. 800

b) 25 mm Mtr. 600b) 25 mm Mtr. 600

7.0 JELLY FILLED TELEPHONE CABLE

7.1Supplying of following polyethylene insulated jelly filled armoured telephonecables as per DOT specification.

a) 50 pair, 0.5mm copper armoured cable Mtr. 150

b) 20 pair 0.5 mm copper unarmoured cable Mtr. 100

Page 91: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

7.2Excavation and trenching one meter depth and 0.3m width including refillingwith excavated earth after laying of jelly filled telephone cable dressing, sandcushing and protective bricks covering etc as required.

Mtr. 250

7.3Laying of jelly filled cable in trenches (excavated under item 7.2) as per DOTSpecification including transportation, loadning & unloading of cable fromconcernd store depot to work site of following jelly filled cable

a) 50 Pair. Mtr. 150

b) 20 Pair. Mtr. 100

8.0 COMPUTER WIRING AND LAN CABLING

8.1Supplying and laying of UTP 4 pair Cat-6 computer Networking cable n existingPVC conduit and terminaiton etc., as required (one run).

Mtr. 15000

8.2Providing, fitting & fixing of computer point RJ-45 of approved make computersocket in compatiable MS/PVC box, screw etc., as required.

No. 550

8.3 Supplying & laying of following size PVC conduit recessed in wall/celling

a) 20 mm Mtr. 8000

b) 25 mm Mtr. 6000

8.4 Installation of 6 U wall mounted rack for Patch panel No. 2

Page 92: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

9.0 FIRE DETECTION & ALARM SYSTEM

9.1

Supply, installation, testing & commissioning of intelligent plug in photo electricsmoke detectors having features like integral communication, dual LED for 360˚viewing angle, walk test with address display etc. UL / LPCB approved, Make :HONEYWELL, MORLEY IAS, Model : MI - PSE or equiv.

No. 88

9.2

Supply, installation, testing & commissioning of intelligent plug in thermaldetectors having features like integral communication, dual LED for 360˚viewing angle, walk test with address display etc. UL / LPCB approved, Make:HONEYWELL, MORLEY IAS, Model : MI - RHSE or equiv.

No. 10

9.3Supply, installation, testing & commissioning of Addressable hooter completewith control module.UL / LPCB approved, Make - HONEYWELL, MORLEY IAS,Model - MI - LASR + NBD / R or equiv.

No. 8

9.4

Supply, installation, testing & commissioning of Dual action pull station withaddressable interface, built in bicolour LED with key reset facility & smooth dualaction design.UL / LPCB listed. Make : HONEYWELL, MORLEY IAS, Model :MI - LASR + NBD / R or equiv.

No. 12

9.5Supply, installation, testing & commissioning of response indicator to give visualindication of detection of smoke - RED colour LED for indication. Make - AgniSuraksha, System Sensor.

No. 20

9.6

Supply, installation, testing & commissioning of 4 Loop Intelligent / AnalogueAddressable Fire Alarm Panel Microprocessor based character display Networkoption built in Alarm, Trouble & supervisory relays LPCB listed. Make :HONEYWELL, MORLEY IAS, Model - ZX 5 e or equiv.

No. 1

Supply, installation, testing & commissioning of Addressable Base Model -9.7

Supply, installation, testing & commissioning of Addressable Base Model -Detectors, LPCB approved, Make - HONEYWELL, MORLEY IAS or equiv.

No. 98

9.8Wiring with 1100V grade PVC insulated copper conductor in existing PVC / MSconduit (including supply of wire)

i) 3 x 1.5 mm2 RM 1100

9.9 Supply and laying of following PVC conduit recessed in wall/ ceiling

i) 20 mm RM 500

Page 93: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

10.0 MISCELLANEOUS ITEMS

10.1Providing, laying and jointing GI pipes of medium class including excavationand back filling all complete as pipe ducts for passing services through roads,pavements, foundations, floors, etc.)

a) 50 mm dia Mtr. 20

b) 100 mm dia Mtr. 10

c) 150 mm dia Mtr. 10

10.2

Supplying & installing of perforated, pre-painted M.S. cable trays withperforation not more than 17.5% in convenient sections joined with connectors,suspended from the ceiling with M.S. suspenders including bolts & nuts paintingetc., as required.

a) 100 mm width x 50 mm depth x 1.6 mm thick Mtr. 50

b) 150 mm width x 50 mm depth x 1.6 mm thick Mtr. 200

c) 225 mm width x 50 mm depth x 1.6 mm thick Mtr. 20

d) 300 mm width x 50 mm depth x 1.6 mm thick Mtr. 200

TOTAL (PART - C : Electrical Works)

Page 94: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

1 EQUIPMENTUnit Qty

Rate (INR in

Figure) Rate in words Amount(INR)

Double Skin Air Handling Units

a Double skin floor mounted AHU 8.0 TR, 3700 CFM, 65 mm SP, 6 RD, 12 FPI

with mixing boxNo 4

b

Double skin floor mounted AHU 4.0 TR, 1600 CFM, 65 mm SP, 6 RD, 12 FPI

with mixing box No 1

c

Double skin floor mounted AHU 11 TR, 5400 CFM, 65 mm SP, 6 RD, 12 FPI

with mixing box No 10

d

Double skin floor mounted AHU 12 TR, 5800 CFM, 65 mm SP, 6 RD, 12 FPI

with mixing box No 1

1.2 Double Skin Ceiling Suspended Air Handling Units

aS/I/T/C of Double skin Ceiling suspended AHU 4 TR, 1600 CFM, 35 mm SP, 6

RD, 12 FPI i/c all accessories complete as required. No 2

1.3 Fan Coil Unit

Supply , installation, testing and commissioning of Low height Inverter driven

lownoise fan coil unit complete with hidden/ exposed with 3 RD cooling coils ,

3 speed fan, extended drain pan (sandwitched construction

only),thermostate,wiring and pre filters. Suitable for 230 V, 50Hz single

phase power connection.Coil face velocity shall be limited to 350 FPM.

a 2.0TR No 7

b 1.5TR No 4

1.4

Supply, installation, testing and commissioning of Double Skin Plenum

Box with Microvee filter of efficiency 95% down to 3 micron of folloiwng sets

along with necessary trap doors. The Height of the Plenum box should not be

more than 1225mm complete as required.

a4 nos 600 x 600 x 300 (depth Microvee Filter

Nos 4

b6 nos 600 x 600 x 300 (depth) microvee filter Nos 10

1.5

Supply, Installation, Testing & Commissioning of Desicent Rotor Heat

recovery wheel with DIDW Centrifugal Forward Curved Supply & Exhaust fan,

Sq. Cage Motor for Supply & Exhaust fan & HRW Wheel, The unit shall be

completely factory fabricated with purge arrangement and having minimum

65% efficiency complete as required

Name of Work : Construction of Central Instruments Facility (CIF) Building

Supply, installation, testing and commissioning of sheet metal

sectionalised construction thermal break type double skin AHU of following

capacity with Chilled water cooling coil, 50 mm thick prefilter having efficiency

90% down to 10 micron, Microvee Filter Section sutable to accomodate

300 mm Microvee filter, squirrel cage induction motor,DIDW centrifugal

backward curved fan, belt drive package and vibration isolation (spring

mounted), insulated drain pan,thermostate,wiring etc. as per specification

complete as required.

PART - D : HVAC WORKS

1.1

Page 95: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

a750 CFM

No 1

b 300 CFM No 1

1.6AUTO AIR VENT

a

Supply, installation, testing and commissioning of Auto Air vents at the highest

points in the chilled water piping as per approved makes and specifications 50

mm Dia Auto Air Vents complete as required.

No 14

1.7

Supply, installation, testing and commissioning of 2kwX3strip heater bank on

the duct with thermostat & dehumidifier,control connection ,DOL starter etc

complete as required,

No 8

2 PIPING

2.1.1Providing and fixing in position the following MS HEAVY class chilled water

piping, cut to required length and installed with welded joints,including at

necessary fittings such as elbow, tees, etc. And confirming to the

a 150 mm dia RM 10

b 100 mm dia RM 200

c 80 mm dia RM 160

d 65 mm dia RM 140

e 50 mm dia RM 210

f 40 mm dia RM 114

g 32 mm dia RM 52

h 25 mm dia RM 48

2.2Providing and fixing of Chilled water pipe insulation with 25 mm thk. Al. Foil

Faced Closed cell Nitrile rubber pipe Section with approved thermal protection

layer etc Complete as required as per specification as required.a 150 mm dia RM 10

b 100 mm dia RM 200

c 80 mm dia RM 160

d 65 mm dia RM 140

e 50 mm dia RM 210

f 40 mm dia RM 114

g 32 mm dia RM 52

h 25 mm dia RM 48

Supply, Installation, testing & Commissioning of CHILLED WATER PIPING as

per IS 1239 with all necessary supports MS / Civil etc as required as per site

condition and as per specification with MS Heavy class pipe, fittings etc.2.1

TOTAL CARRIED OVER TO SUMMARY (EQUIPMENT)

Page 96: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

2.3Providing and fixing of Chilled water pipeline Valve insulation as per chilled

water pipe insulation complete as required.Lot 1

2.4 Drain Water Piping (GI PIPE)

2.4.1Providing and fixing of Condensate drain water pipeline with 19 mm thick

al.foil facia closed cell nitrile rubber pipe section complete as required.

a 50 NB RM 100

b 25 NB RM 40

2.5 Drain Water Piping Insulation

condensate drain water insulation with 19 mm thick AL. foil faced closed

cell Nitrile rubber pipe section complete as required

a 50 NB RM 100

b 25 NB RM 40

2.6Excavation of trench Trench work to take the chilled water piping upto 250 mm

dia and refilling with excavated soil with compaction with fine sand.RM 20

2.7

Supply, Installation, testing & Commissioning of Underground CHILLED

WATER PIPING with insulation with 75 mm thick expanded. polystyrine of 20

kg/cm3 density .covered with chickenwire mesh,10mm cement sand plaster .

2 layes of terfelt and finally painted the bituminus paint in 2 layers. All the

pipes will be as per IS 1239 with all necessary supports MS / Civil etc as

required as per site condition and as per specification with MS Heavy class

pipe, fittings etc comp-lete as required.

a 150mm dia RM 30

b 100mm dia RM 20

3Providing and fixing in position the following insulated butterfly valves i/c

all accessories complete as required..

a 100 mm dia No. 4

b 50 mm dia No 20

c 40 mm dia No 8

d 32 mm No 4

3.1Providing and fixing in position the following insulated ball valves with

strainner complete as required..

a 25 mm dia Set 12

3.2

Providing and fixing in position Industrial type pressure gauges with ball

valves for isolation and necessary fittings for the USE of maintenance

and operation complete as required.

No 28

3.3Providing and fixing in position stem alcohol filled industrial

thermometers comple as required.No 28

3.4Supply, installation, testing and commissioning of insulated Electronic,

Self-balancing Pressure independent type dynamic balancing valve with

integrated 2 way modulating control valves in a single body. The actuator shall a 20 mm dia No 12

b 25 mm dia No 2

Page 97: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

c 32 mm dia No 4

d 40 mm dia No 10

3.5

Supply, Installation, testing & Commissioning of Proportional type thermostat

having 0-10V DC / 4-20mA output with Controller suitable to work with the

above valve or VFD input for AHU of approved make.

No 30

3.6Providing and fixing in position the following insulated Y-Strainers i/c all

accessories complete as required.

a 50 mm dia No 10

b 40 mm dia No 4

c 32 mm dia No 2

4 AIR DISTRIBUTION

a 0.63 mm (24 gauge) GSS Sqm 900

b 0.8 mm (22 gauge) GSS Sqm 200

4.2

Supply, installation and testing of multiblade type louver damper of MS sheet

for Fresh air to be provided with suitable links, levers and quadrants for

manual control of volume of Fresh air flow as per approved shop floor

drawings and specifications complete as required..

Sqm 2

4.3

Supply, installation and testing of multiblade box type GSS construction

damper for ducts to be provided with suitable links and Supply, installation

and testing of multiblade box type GSS quadrants for control of volume of

air. Complete as required .

Sqm 6

4.4

Supply, installation, testing and commissioning of motorized combination

fire and smoke damper (spring return type) of approved make of atleast 90

minute fire rating and as per the specifications as detailed earlier in the

relevant sections. The fire damper shall be complete with electronic

temperature sensor and electrically operated actuator. The fire dampers

shall be located in the supply /return air ducts at all fire rated crossovers

(shaft/walls etc.) The control panel will be such located that the reset can be

easily done.These combination smoke and fire dampers shall be interlocked

withthe building management system for fire detection / HVAC and shall

trip/close in the event of fire / smoke in the respective zone.(a+b++c)

aProviding and fixing,Bare Fire Dampers with sleeve and fixing arrangement.

Sqm 6

b

Providing and fixing,Control panel actuator including Electrical spring type

actuator with smoke sensor and remote indication of the dire damper

positionand control wiring etc as required..

No 16

cInterconnecting wiring for the fire alarm system with the AHU and the smoke

dampersLot 16

4.5

Supply, installation, testing and commissioning of Fusible link type fire damper

of approved make of atleast 90 minute fire rating with Limit Switch and as per

the specifications as detailed earlier in the relevant sections for return air

duct.(a+b+c)

TOTAL CARRIED TO SUMMARY (PIPING) Rs

Supply, Fabrication, Installation and testing of sheet metal ducts in

accordance with the approved shop floor drawings and specifications

and shall also confirm to the ISI specifications

4.1

Page 98: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

a Bare Fire Dampers with sleeve and fixing arrangement Sqm 8

b Fusible link for fire damper No 14

c Interconnecting wiring for the Fire damper limit switch with AHU stater Lot 14

4.6

Supply, installation, testing and commissioning of square supply air diffusers

as per approved shop floor drawings and colour. Each diffuser will be

equipped with removable core and a aluminium volume control damper which

will be key operated complete as required.

aPowder coated extruded aluminium supply air diffuser with VCD of approved

colour and shade complete as required.Sqm 15

bPowder coated extruded aluminium supply air grill with VCD of approved

colour and shade complete as required.Sqm 4

4.7

Supply, installation, Testing and commissioning of Linear Grill for return air

diffuser as per approved shop floor drawings and colour. Each diffuser will be

equipped with removable core

aPowder coated extruded aluminium return air Grill of approved colour and

shadecomplete as required.Sqm 30

bPowder coated extruded aluminium return air diffuser/grill of approved colour

and shadecomplete as required. Sqm 6

5.1Supply and Application of accoustic lining within the supply air duct as per

specifications and drawings

a25 mm thick, 48 kg/m3 density FGP with 24G aluminium perforated sheet,

tissue paper as per specification etc as required.Sqm 200

5.2

Supply and Application of external thermal insulation of ducting with Self

Adehisive type Closed Cell Nitrial Rubber/FR XLPE with aluminium foil facia

and of density as specified in the specifications

a 19 mm thick for Supply air Sqm 900

b 13 mm thick for Return air Sqm 100

5.3

Supply, fixing and application of under deck insulation of roof exposed to

direct Sun with 25 mm Self Adhesiv type Close Cell Nitrial Rubber /FR XLPE

with necessary accessories complete as required..Sqm 1200

5.4 AHU Room WALL accostic Lining

a

Supply,installation,testing and commissioning of accoustion lining on all sides

of walls of each AHU room with fibreglass ,tissue paper and 24 gauge

perforated aluminium sheet.The fibre glass insulation shall be of 50

mmx32kg/m3 of board type and shall be fixed on GI frame as per site

condition and specification as required.

Sqm 250

5.5Supply,installation,testing and commissioning of Inline Exhaust Fan complete

as required.

a 300 CFM No 2

6

TOTAL CARRIED TO SUMMARY (AIR DISTRIBUTION) Rs

ELECTRICAL WORKS

INSULATION5

TOTAL CARRIED TO SUMMARY (INSULATION) Rs

Page 99: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

6.1

Design, fabrication, assembling, wiring, supply, installation, testing and

commissioning of following LT panels fabricated out of 14 gauge CRCA

sheet steel in cubical formation with reinforcement of suitable size angle iron

and channel T iron flats. All steel material used in the construction of panels

shall undergo seven tank process before painting as per standards with 2

coats of red oxide primer and final approved shade of enamel paint. A solid

busbar shall be provided at the bottom of the panel with two connecting eyes

for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase, 4

wire supply system. All the hardware used in the fabrication of the panel shall

be galvanized with zinc passivation. The panel shall be compartmentalized

to accomodate one feeder in eachcompartment. A vertical cable alley of

suitable width shall be provided to serve on or two vertical feeder

sections. Also the opening between the busbar chamber and the feeder

section shall be shrouded with bakelite/hylam sheet with mm 3 mm

thickness.All panels to have Auto Manual switches to make them compatible

Facility Management System (BMS).The panel drawing shall be approved

before taking up the fabrication.

6.1.1All panels to have Auto-Manual switches to make them compatible with

Facility Management System (BMS)

6.2 CABLING (POWER)

6.2.1 Power Cabling and Earthing

Electrical contractor but the terminations shall be done by the HVAC

contractor

PVC insulation PVC sheathed armoured Aluminium FRLS cable of 1.1 kv

grade with termination glands and GI earthing identification tags, clamps,

saddles etc.

a 3C x 6 sqmm RM 70

b 3C x 6 sqmm RM 30

6.2.2 Control Cabling

aCopper conductor, PVC insulated PVC sheathed armoured FRLS cable of 1.1

kv grade 2C x 1.5 sqmmRM 134

6.2.3 Cable Trays

The panel drawing shall be approved before taking up the fabrication

2 KW AHU stater panel with 2 KW VFD & DOL Bypass stater having MCCB

as incomer, phase indicating lamp, voltmeter, volt meter selecting switch,

semiconductor fuse for VFD, control fuse, 24V 50VA transformer for Fire

damper actuator & Dynamic balancing valve, toggle switch, start / Stop push

button for stater, power & Control terminals etc as per specification and of

approved make.The Panel Should also have 2 nos feeder for Supply &

Exhaust fan of HRW & One No. Feeder for Wheel

No 14

1 KW AHU stater panel with 1 KW VFD & DOL Bypass stater having MCCB

as incomer, phase indicating lamp, voltmeter, volt meter selecting switch,

semiconductor fuse for VFD, control fuse, 24V 50VA transformer for Fire

damper actuator & Dynamic balancing valve, toggle switch, start / Stop push

button for stater, power & Control terminals etc as per specification and of

approved make. (VFD will be supplied with Panel)

2

a

6.1.11

b No

Page 100: TENDER DOCUMENT · Providing reinforcement for RCC work including straightening ... bressummers & cantilevers including sloping beams. Sq.M. 6,486.00 (e) Column, pillars, posts &

6.2.31

P/F cable trays of ladder type made of GI slats 100 mm high and 2.6 mm

thick complete with clamps and suspension arrangement comprising of

MS rods (10 mm dia) etc. duly painted with Polyurethane plant.

a 100 mm wide RM 75

TOTAL PART AC WORKS ,PART :E

SUMMARY

TOTAL CARRIED OUT TO SUMMARY (ELECTRICAL)

EQUIPMENT

PIPING

AIRDISTRIBUTION

ELECTRICAL WORKS

INSULATION