Tek-CARE ® NC110 Visual Nurse Call Signaling System UL ® 1069 Listed Operation, Installation and Service Manual The Tek-CARE ® NC110 Visual Nurse Call Signaling System is designed for nursing home or individual ward use. The nurse call system provides audible and visual indication of all calls originating in the system, including both normal and emergency calls. The NC110A and NC110N Master Stations contain lamps for call indication, as well as tone-off switch and an audible tone signaling device. IL381 SECTION E Rev. 19 - 07/2014 www.tektone.com Phone: (828) 524-9967 Toll-Free: (800) 327-8466 Sales: Option 2 Tech Support: Option 3 277 Industrial Park Road Franklin, NC 28734 [email protected] Fax: (828) 524-9968

Upload: phungphuc

Post on 11-Feb-2018

219 views

Category:

Documents


1 download

TRANSCRIPT

Tek-CARE® NC110Visual Nurse Call Signaling System

UL® 1069 Listed

Operation, Installation and Service Manual

The Tek-CARE® NC110 Visual Nurse Call Signaling System is designed for nursing home or individual ward use. The nurse call system provides audible and visual indication of all calls originating in the system, including both normal and emergency calls. The NC110A and NC110N Master Stations contain lamps for call indication, as well as tone-off switch and an audible tone signaling device.

IL381SECTION ERev. 19 - 07/2014

www.tektone.com

Phone: (828) 524-9967Toll-Free: (800) 327-8466 Sales: Option 2Tech Support: Option 3

277 Industrial Park RoadFranklin, NC [email protected]: (828) 524-9968

ii • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Operation, Installation and Service ManualCopyright © 2001–2014 TekTone® Sound & Signal Mfg., Inc., All rights reserved.

No part of this publication may be copied without the express written permission of TekTone® Sound & Signal Mfg., Inc. The content of this manual is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by TekTone® Sound & Signal Mfg., Inc. TekTone® Sound & Signal Mfg., Inc. assumes no responsibility or liability for any errors or inaccuracies that may appear in this documentation.

TekTone, the TekTone logo, Tek-Alert, Tek-Bridge, Tek-Call, Tek-Care, Tek-Check-In, Tek-Com, Tek-Entry, Tek-Guard, Tek-Micro, Tek-MMARS, Tek-Paging, Tek-Safe and Tek-Status are either registered trademarks or trademarks of TekTone® Sound & Signal Mfg., Inc. in the United States and/or other countries. All other trademarks are the property of their respective owners.

TekTone® Sound & Signal Mfg., Inc., 277 Industrial Park Road, Franklin, North Carolina 28734, USA.

IL381 Tek-CARE® NC110 Manual • iiiCopyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Table of Contents

System Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1NC110N Master Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1NC110A Master Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3SF100C, SF102, SF100N, SF100/2 Call Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . 3SF101C, SF101N Call Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3SF155B, SF339, SF151N, SF153N Emergency Stations and SF156B Code Station . . 4LI150B, LI150N Duty Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5LI382LED Corridor/Zone Lights, LI381 Corridor Lights . . . . . . . . . . . . . . . . . . . . 5LI382LED Corridor/Zone Lights, LI382 Zone Lights . . . . . . . . . . . . . . . . . . . . . . . 5

System Operating Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6PK152, PK151A Power & Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6PK800A Secondary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6NC110N Master Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6NC110A Master Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7SF100C, SF100N, SF100/2, SF101B, SF101C, SF101N, SF102 Call Stations . . . . 7SF155B, SF339, SF151N, SF153N Emergency Stations and SF156B Code Station . . 7

System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Equipment Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Wiring Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Station Wiring Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Housing Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Wire Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Wire Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Connections Checkout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12System Test Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12System Checkout and Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

System Maintenance Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14NC110A Master Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14NC110N Master Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14PK152, PK151A Power & Control Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15PK153 Third Priority Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15PK800A Secondary Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154A Fast-Blow Fuse Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15SF100C, SF100N, SF100/2, SF102 Call Stations . . . . . . . . . . . . . . . . . . . . . . . . . . 16SF101C, SF101N Call Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16SF155B, SF339, SF151N, SF153N Emergency Stations and SF156B Code Station . 16LI150B, LI150N Duty Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16LI381 Corridor and LI382 Zone Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Table of Contents

iv • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

IllustrationsFigure 1—NC110N Master Station Control Locations . . . . . . . . . . . . . . . . . . . . . . 1Figure 2—NC110A Master Station Control Locations . . . . . . . . . . . . . . . . . . . . . . 2Figure 3—Call Station and Call Cord Control Locations . . . . . . . . . . . . . . . . . . . . 2Figure 4—Emergency, Code, Call & Duty Station Control Locations . . . . . . . . . . 4Figure 5—Master Panel Housing Chart and Wall Cut-Out Details . . . . . . . . . . . 10Figure 6—Ring & Back Box for Call, Emergency, Code & Duty Stations,

and Corridor & Zone Lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Figure 7—SS106 Transformer Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Figure 8—NC110N Selector Lamp/Switch Lens, Filter and Lamp Replacement . . 14Figure 9—Block Wiring Diagram without Zone Lamps . . . . . . . . . . . . . . . . . . . . 17Figure 10—Block Wiring Diagram with Zone Lamps . . . . . . . . . . . . . . . . . . . . . 18Figure 11—NC110A Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Figure 12—NC110N Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Figure 13—NC150N, NC200N, Two Stations in Parallel . . . . . . . . . . . . . . . . . . . 21Figure 14—NC110A Housing Installation Diagram . . . . . . . . . . . . . . . . . . . . . . . 22Figure 15—PL116 Wall Plate Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Figure 16—NC110N Second Master Wiring Diagram . . . . . . . . . . . . . . . . . . . . . 23Figure 17—PK153 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Figure 18—PK153 Wiring Diagram with SF156B Code Station . . . . . . . . . . . . . 25Figure 19—PK152 or PK151A to PK800A Interconnection . . . . . . . . . . . . . . . . 26Figure 20—SF337C Cross Reference Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Figure 21—SF339 Cross Reference Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Figure 22—NC110N Hookup to NC150N, NC200N . . . . . . . . . . . . . . . . . . . . . . . 29Figure 23—SF157 and SF157/2 Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . 30

IL381 Tek-CARE® NC110 Manual • 1Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure 1—NC110N Master Station Control Locations

1 – ToneOffButton: Silences normal call tone when depressed. – ToneOffLamp: Indicates tone silenced when illuminated.

2 – ToneTestButton: Activates tone signal when depressed.

3 – Call Lamp: Indicates incoming call when illuminated. Indicates emergency call when flashing.

4 – Emergency Lamp: Indicates emergency call when flashing.

5 – Station Selector Lamps (PM110/4N): Indicates incoming call from associated remote when illuminated. Indicates emergency call from remote when flashing.

6 – LampTestButton: Illuminates all lamps on panel when pressed.

System Operating Instructions

This section provides complete operating instruction for all Tek-CARE® NC110 functions, as well as reference drawings for use in locating and describing all controls. System operators must read the following operating instructions concerning system equipment and the terms used in conjunction with the equipment.

NC110N Master StationsRefer to Figure 1 for locations, names, and functions of controls and indicators.

Answer Emergency Calls:All emergency calls take precedence over any normal call signal. Calls must be answered in person and can only be canceled from point of origin. Emergency calls are indicated by simultaneous operation of the following signals:

• Rapid flashing of the associated station selector lamp, which is marked to indicate origin of call.

• Rapid flashing of call lamp and emergency lamp.

• Rapidly pulsing audible tone.

Answer Normal Calls:Calls must be answered in person and can only be canceled from point of origin. Normal calls are indicated by simultaneous operation of the following signals:

• Steady illumination of the associated station selector lamp which is marked to indicate origin of call.

• Steady illumination of call lamp.

• Slowly pulsing audible tone. The audible call signal may be canceled for normal calls by pressing the tone off button. The tone off button will then illuminate to indicate tone silenced. Pressing the tone off button when illuminated will reset the call tone.

Drawing Name & Number: IL381 NC110N Product Rev0 121902 1

2 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure 2—NC110A Master Station Control Locations

POWER

TONETEST

TONE

VOLUME

OFF

EMER.

CALLCALL INDICATOR

EMERGENCY CALL INDICATOR

ROUTINE TONE OFF

TONE VOLUME SELECTOR

CALL TONE TEST

SYSTEM POWER INDICATOR ROOM INDICATORS

1 – Call Placed Lamp: Indicates a call is placed when flashing.

2 – CancelButton: Cancels the call when pressed.

3 – Call Cord Jack: Receptacle for SF301A or SF302 call cord.

4 – Plug: Connects call cord to patient station when plugged into call cord jack.

5 – CallButton: Places a call when pressed, if cord is connected to patient station.

SF100N Call Station SF100/2 Dual Call Station

4

5

SF301A Call Cord

SF302 Call Cord

SF100C Call Station

SF102 Dual Call Station

IL381 SF100C Product Rev0 121902 1

IL381 SF102 Product Rev0 121902 1

Figure 3—Call Station and Call Cord Control Locations

System Operating Instructions

IL381 Tek-CARE® NC110 Manual • 3Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Test Tone Signal: Press the tone test button. A tone signal should be heard at the master station.

Test Station Selector Lamps: Press the lamp test button (one is included for each panel of annunciator lamps). All annunciator lamps on that panel should be illuminated. (See System Maintenance Instructions for proper procedures and precautions in replacing defective lamps.)

Improper Operation:• If the NC110N Master Station fails to operate as described, contact qualified service

personnel. There are no user replaceable parts on the NC110N Master Station other than the station selector lamps and lenses.

• If a malfunction occurs during a call and causes a lack of indication of call origin on the master station, first determine the origin of the call by observing which corridor light and corridor zone light is illuminated, then inform qualified service personnel.

NC110A Master StationsRefer to Figure 2 for locations,  names, and functions of controls and indicators. Operation of the NC110A is similar to that of the NC110N, except that there is no selector lamp test (NC110A has selector LEDs instead).

Adjust volume:The NC110A master station has three volume levels. Press the volume button until the desired level is reached. The level is indicated by three lighted LEDs above the volume button. Use the tone test button to test volume when adjusting the volume.

Selector point labeling:A slot is provided at the top of each column of selector points for inserting a paper strip (TekTone® part number LB516). Apply room-identifying labels between the dashed lines so that each label lines up with the intended selector point on the NC110A membrane switch.

SF100C, SF102, SF100N, SF100/2 Call StationsRefer to Figure 3 for locations, names, and functions of controls and indicators.

Call a Nurse: Press the call button located on the end of the call cord. The call placed lamp will illuminate to indicate call placement. Wait for the nurse. Refer to Figure 3 for locations, names, and functions of call cord controls.

Cancel a Call: Press the cancel button. Indicator will go off. If the call cord is pulled from its receptacle, a call will be placed automatically and cannot be canceled until the call cord is replaced in the receptacle.

Replace Call Cord: See System Maintenance Instructions for proper procedures and precautions in replacing defective call cords.

Improper Operation: If the call station does not operate as described, contact qualified service personnel. There are no user serviceable parts on the SF100C, SF102, SF100N and SF100/2 Call Stations other than cords.

SF101C, SF101N Call StationsRefer to Figure 4 for locations, names, and functions of controls and indicators.

Call a Nurse: Press the call button. The call placed lamp will illuminate to indicate call placement. Wait for the nurse.

System Operating Instructions

4 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Cancel a Call: Press cancel button. Indicator will turn off.

Improper Operation: If the call station does not operate as described, contact qualified service personnel. There are no user serviceable parts on the SF101C and SF101N Call Stations.

SF155B,SF339,SF151N,SF153NEmergencyStationsandSF156BCodeStationRefer to Figure 4 for locations, names, and functions of controls and indicators.

Call a Nurse: Pull the call cord, slide the call/cancel switch down, or press the call/cancel button. The call placed lamp will flash. Wait for the nurse.

Cancel a Call: Push the call/cancel switch up, press the call/cancel button, or twist the push button. The call placed lamp will go off.

Figure 4—Emergency, Code, Call & Duty Station Control Locations

1 – Call Placed Lamp: Indicates a call is placed when flashing.

2 – CancelButton: Cancels the call when pressed.

3 – CallButton: Places a call when pressed.

4 – Call/Cancel Switch: Places a call when pulled down. Cancels the call when pushed up.

5 – Call Cord: Places a call when pulled.

6 – Call/CancelButton: Places a call when pressed to in position. Cancels the call when pressed or twisted to out position.

7 – ToneOffSwitch: Silences normal audible tone signal when pushed down.

SF151N Emergency Station

SF153N Emergency Station

SF101N Call Station

SF101C Call Station

IL381 SF101C Product Rev0 121902 1

LI150BDutyStation

Tone Off

IL381 LI150B Product Rev0 122002 1

LI150N Duty Station

IL381 LI150N Product Rev0 122002 1

SF155BEmergencyStation

SF156BCodeStation

SF339EmergencyStation

System Operating Instructions

IL381 Tek-CARE® NC110 Manual • 5Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Improper Operation: If the call station does not operate as described, contact qualified service personnel. There are no user serviceable parts on the SF155B, SF339, SF151N, SF153N Emergency Stations or the SF156B Code Station.

LI150B,LI150NDutyStationsRefer to Figure 4 for locations, names, and functions of controls and indicators.

Emergency Calls: Emergency calls are indicated by a flashing call placed lamp and a rapidly pulsing audible tone. The audible tone signal cannot be silenced by the tone off switch.

Normal Calls: Normal calls are indicated by steady illumination of the call placed lamp and a slowly pulsing audible tone. Push the tone off switch down to silence the audible tone signal. Push the tone off switch up to turn the audible tone signal on.

Improper Operation: If the call station does not operate as described, contact qualified service personnel. There are no user serviceable parts on the LI150B and LI150N Duty Stations.

LI382LED Corridor/Zone Lights, LI381 Corridor LightsEmergency Calls: Emergency calls are indicated by rapid flashing of the corridor light

that is associated with the calling station.

Normal Calls: Normal calls are indicated by steady illumination of the corridor light that is associated with the calling station.

Lamp Replacement: See System Maintenance Instructions for proper procedures and precautions in replacing defective LI381 lamps.

Improper Operation: If corridor light does not operate as described, contact qualified service personnel. There are no user serviceable parts on the LI382LED Corridor/Zone Lights. There are no user serviceable parts on the LI381 Corridor Lights other than lamps.

LI382LED Corridor/Zone Lights, LI382 Zone LightsThe LI382 Zone Light includes two indicator lamps: a clear normal call indicator lamp and an emergency call indicator lamp with a red bulb cover. The LI382LED Corridor/Zone Light includes four indicator LEDs: two clear normal call indicator LEDs that operate in unison, and two red emergency call indicator LEDs that operate in unison.

Emergency Calls: Emergency calls are indicated by rapid flashing of the red corridor zone light(s) associated with the zone or area from which an emergency call has been placed.

Normal Calls: Normal calls are indicated by steady illumination of the white corridor zone light(s) associated with the zone or area from which a normal call has been placed.

Concurrent Emergency and Normal Calls: If an emergency and normal call are placed in the same zone at the same time, the red light(s) connected to the emergency station from which a call was placed will flash rapidly, while the white light(s) associated with the normal call will maintain a steady illumination.

Lamp Replacement: See System Maintenance Instructions for proper procedures and precautions in replacing defective LI382 lamps.

Improper Operation: If corridor zone light does not operate as described, contact quali-fied service personnel. There are no user serviceable parts on the LI382LED Corridor/Zone Lights. There are no user serviceable parts on the LI382 Corridor Zone Lights other than lamps and red bulb cover.

6 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Operating Principle

Each system uses a series of bus conductors to carry the operating and signaling voltage to the various units. In addition, each station capable of calling the master station has individual conductors between it and the master to give the station its own identity.

When a call button is depressed, switching circuits operate to light various call lights and to energize system call tone. All calls must be reset at the point of origin.

Emergency calls are signaled by a different flashing rate at the master station. An emergency call is indicated by an intermittent tone and flashing lights at approximately 1/3-second intervals. A normal call is indicated by a steady lamp and an intermittent tone at approximately 8-second intervals.

The Tek-CARE® NC110 Nurse Call System includes three basic units, each essential for operation. These will be discussed individually and are as follows:

• Power & Control Unit• Master Station• Call Stations

The use of these basic units, in conjunction with wiring, housings and auxiliary equipment, make up a complete system.

PK152, PK151A Power & Control UnitsThe power & control unit utilizes a transformer which steps down the 120 VAC input to 24 VAC, 30 VA, which is then rectified, filtered and regulated to provide a stable 24 VDC for the rest of the system.

Control circuits are provided to detect the presence of normal or emergency calls and to provide steady or intermittent voltages to operate external devices with indications as follows:

Normal calls are indicated by a positive voltage applied to Terminal R by the calling remote station. Emergency calls are indicated by a positive voltage applied to terminal Q by the calling remote station.

PK800A Secondary Power SupplyThe secondary power supply accepts a 24 VAC input from the SS100 transformer. It rectifies, filters and regulates a +24 VDC output, which is provided on the two terminals labeled “24 VDC.” A +5 VDC output is also available, but is not used in this application.

NC110N Master StationsThe Master Station includes:

• Buzzer for audible signals.• Annunciator lamps for call indication.• Additional operating controls, including tone off and tone test switches and

additional emergency and normal call indicators.

System Operating Principle

IL381 Tek-CARE® NC110 Manual • 7Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

NC110A Master StationsThe NC110A’s design is based on the NC110N master station. The NC110N’s control switches have been replaced with relays that have reliable control circuitry, which are operated via the buttons on the NC110A membrane switch. The NC110A uses an electronic oscillator circuit to generate call tones via an enclosed 45-ohm speaker. A simple digital counter keeps track of tone volume and is advanced by pressing the volume button.

The NC110A includes an isolated N/O relay contact for ancillary off-board call handling. An RC hold circuit keeps the contact closed during off cycles of the call indication LED. For this reason, the contact will remain closed for a few seconds after call activity at the station has ended.

SF100C,SF100N,SF100/2,SF101B,SF101C,SF101N,SF102CallStationsThe SF100C, SF100N, SF100/2, SF101C and SF102 Call Stations are for normal calls that use an LED visual indicator.

Pressing the momentary call button initiates a routine level call. A latching circuit maintains signaling after the call button has been released. Pressing the cancel button cancels the call.

Call stations SF101B and SF101N have different features, but function in a similar manner.

SF155B,SF339,SF151N,SF153NEmergencyStationsandSF156BCodeStationThe SF155B Emergency Station is for emergency calls. In the emergency position, associated signal lights are disconnected from the normal signal terminals and connected to the emergency signal terminals.

Emergency stations SF339, SF151N and SF153N, and code station SF156B have different features, but function in a similar manner.

8 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Installation

Installation ProcedureStep 1: Read the following instructions concerning system equipment and determine

installation methods before proceeding.

Step 2: Determine equipment location.

Step 3: Install wiring.

Step 4: Install housing.

Step 5: Check wires.

Step 6: Connect equipment.

Step 7: Check connections.

Equipment LocationsNC110A, NC110N Master Stations: Locate master stations within easy reach of operating

personnel. Do not exceed operating temperature of 10° C–30° C.

SF100C, SF101C, SF102 Call Stations: Locate call stations where convenient for opera-tion. Calls are placed on the SF100C and SF102 by means of a call cord, permitting easy operation by seated or prone patients. Calls are placed on the SF101C by means of a push button located on the station.

SF155B, SF339 Emergency Stations and SF156B Code Station: Locate emergency sta-tions where convenient for operation. Avoid areas where direct contact with water may occur. The SF155B includes a 6’ long pull cord permitting installation high enough to provide easy operation by the nurse and by seated or prone patients. The SF155B may be used without the cord as a pull down actuated switch.

LI150B Duty Stations: Locate duty stations as needed and where convenient for opera-tion. Location should provide for unobstructed visibility of the call indicator.

LI382LED, LI381 Corridor Lights: Locate corridor lights in the corridor above or beside the door of the associated room. Location should provide for unobstructed visibility of the corridor light in both directions.

LI382LED, LI382 Zone Lights: Locate zone lights in the corridor area nearest the nurses central monitoring station. Location should provide for unobstructed visibility of each zone light from the central location.

SF301-series, SF302-series Call Cords: Insert call cord plugs into associated station jacks as indicated on the stations.

PK152, PK151A Power & Control Units: Locate the PK152 or PK151A and the IH151N junction box in an accessible area. Do not exceed operating temperature range of 10° C–30° C. Location should provide for convenient cable runs to remote and master stations. Cable run from the PK152 or PK151A to the NC110N Master Station must not exceed 100’.

PK153 Third Priority Conrol Unit: Locate the PK153 in the same location as the PK152 or PK151A Power & Control Unit.

System Installation

IL381 Tek-CARE® NC110 Manual • 9Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

PK800A Secondary Power Supply: Locate the PK800A in an accessible area within 2 feet of the PK152 or PK151A that it is to be connected to. Do not exceed operating temperature range of 10°C–30°C. The PK800A is for use in applications that exceed the current load capacity of the PK152 or PK151A (1 amp). The PK800A allows the current load to be increased to 3 amps. The 4A fast-blow fuse assembly (included with the PK800A) must be located between the PK800A and the PK152 or PK151A. See Figure 19 for actual FZ151 connection points.

24 VAC 100 VA Transformer: For use with the PK800A. Locate the transformer within 3 feet of the PK800A Secondary Power Supply. Do not exceed operating temperature range of 10°C–30°C.

Wiring InstallationRun wiring conduit from corridor light to corridor light and terminate at the PK152 or PK151A Power & Control Unit. Limit each run to 15 corridor lights and 600 feet of wire. Select conduit size to accommodate the following cables:

• 3 cond. #18 common to all call stations (except LI150B Duty Stations). Add 2 cond. #18 common if LI382 Zone Lights are used.

• Run 3 cond. #18 common from LI382 to PK152 or PK151A Power & Control Unit.

• 1 cond. #22 selective for each SF155B Emergency Station not used in conjunction with a call station.

• 4 cond. #22 to one LI150B Duty Station. Use 4 cond. #18 if feeding more than one duty station. Install a maximum of 4 duty stations per system. If more are needed, call factory for wiring information.

Station Wiring LayoutNC110A, NC110N Master Stations: Run cable or conduit directly from the master sta-

tion to the PK152 or PK151A Power & Control Unit and the IH151N Junction Box. Include the following:• 5 cond. #18• 1 cond. #22 for each SF100C/SF101C/SF102 Call Station.• 1 cond. #22 for each SF155B Emergency Station not used in conjunction with a

call station.

SF100C, SF101C, SF102 Call Stations: Run 4 cond. #22 directly to associated SF155B Emergency Station. If an emergency station is not used, run cable directly to the associated corridor light. If more than one call station is used in the same room, all stations run directly to the emergency station (if used).

SF155B Emergency Stations: Run 4 cond. #22 for each call station associated with the SF155B. Run cable directly to associated corridor light. If no call station is used, only 3 cond. #22 is needed from the SF155B to the corridor light.

LI150B Duty Stations: Run 4 cond. #22 to the PK152 or PK151A Power & Control Unit. Use 4 cond. #18 if feeding more than one duty station. Install a maximum of 4 duty stations per system. If more are needed, call factory for wiring information.

Power Wiring: Run conduit and 2 cond. #18 cable from the PK152 or PK151A Power & Control Unit and the IH151N Junction Box to 117 VAC - 60 cycle power source. Do not connect power.

Refer to Figure 11 and Figure 12 for typical system wiring and cable sizes.

System Installation

10 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

16″

B

16.25″

Housing InstallationNC110A Master Station:

The NC110A is a desktop unit. Locate the PL116 wall plate directly behind the desk to accommodate the NC110A. Mount the wall plate to a four-gang electrical backbox with a three-gang mud ring (TekTone® part numbers IH353 and IH352 respectively). Connect the NC110A to the wall plate using the provided 8-wire, RJ-terminated cable (CA045) and fixed 50-wire ribbon cable (CA046). Gather extra length in the ribbon cable and tie as shown. See Figure 14 for unit placement.

NC110N Master Station:Flush Wall Mounting: Provide wall cutout as shown in Figure 5. Fit back box and frame assembly into prepared opening. Fasten assembly in place using screws. Back box must be TekTone® OH200-series.

Surface Wall Mounting: Fasten box and frame assembly to wall through holes provided in back of box. Use suitable fasteners. Back box must be TekTone® OH300-series.

Figure 5—Master Panel Housing Chart and Wall Cut-Out Details

Figure 6—Ring&BackBoxforCall,Emergency, Code & Duty Stations, and

Corridor & Zone Lights

Install ring with panel mounting holes at top and bottom, as shown.

Figure 7—SS106TransformerInstallation

B Housing Wall Opening Flush Surface Width (B) Height OH202 OH302 8.5″ 16.25″ OH203 OH303 12.5″ 16.25″ OH204 OH304 16.5″ 16.25″ OH205 OH305 20.5″ 16.25″

B3.75″

Finished Wall4″ min.

B

Finished Floor

66″

16.25″

In masonry walls, install 0.5″×4″ wood fillers at top and bottom of opening for housing attachment.

System Installation

IL381 Tek-CARE® NC110 Manual • 11Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

SF100C, SF101C, SF102 Call Stations, SF155B Emergency Station: Install single gang ring (or single gang ring and double gang box) as shown in Figure 6 for each call and emergency station in the system. Ring and back box must be UL® approved. Minimum dimensions of back box must be not less than 4″×4″×1.5″. Minimum opening on ring must be not less than 1.75″×2.75″. Minimum clearance from live parts on station to dead metal parts must be not less than 0.5″.

LI150B Duty Stations: Install single gang ring (or single gang ring and double gang box) as shown in Figure 6 for each duty station. Ring and back box must be UL® approved. Minimum dimensions are the same as for the call/emergency stations listed previously.

LI382LED Corridor/Zone Lights: Install standard one- or two-gang box with one- or two-gang ring as shown in Figure 6 for each corridor light in system. Ring and back box must be UL® approved. Minimum clearance from live parts of station to dead metal parts to be not less than 0.5″.

LI381 Corridor Lights, LI382 Zone Lights: Install double gang ring (or double gang ring and double gang box) as shown in Figure 6 for each corridor light in system. Ring and back box must be UL® approved. Minimum dimensions of back box must be not less than 4″×4″×1.5″. Minimum opening of ring must be not less than 2.75″×2.75″. Minimum clearance from live parts of station to dead metal parts must be not less than 0.5″.

PK152 or PK151A Power & Control Unit, IH151N Junction Box: Fasten IH151N Junction Box to wall using suitable fasteners. Mount PK152 or PK151A inside junction box. Any alternate junction box must be UL® approved. Minimum dimensions of junction box must be not less than 12″×12″×4″. Minimum clearance from live parts to dead metal parts on housing must be 1″.

Install SS106 Transformer in junction box as shown in Figure 7. Do not connect transformer primary to power source until entire installation is completed and checked for shorts and grounds.

Install transformer connection box as shown in Figure 7. Transformer box must be UL® approved. Minimum dimensions must be not less than 1.75″×3.75″×1.5″. The junction box, transformer and power & control unit are also available preassembled from the factory as part number IH151NK.

PK800A Secondary Power Supply: Fasten PK800A Secondary Power Supply to wall using suitable fasteners.

24 VAC 100VA Transformer: Fasten 24 VAC 100 VA Transformer to wall using suitable fasteners. Do not connect transformer primary to power source until entire installation is completed and checked for shorts and grounds.

Wire CheckoutUse an ohmmeter or other continuity checking device to test wires for shorts or grounds. If shorts or grounds are encountered, find and correct the problem before continuing. Make sure minimum number of conductors needed for all of the equipment being used in the system are available.

System Installation

12 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Wire ConnectionsUse crimp-style connectors for all wire connections. Do not use wire nuts.

NC110A Master Station: Wire the PL116 Wall Plate as shown in Figure 15.

NC110N Master Station: No internal wiring is necessary for the NC110N Master Station.

SF100C, SF101C, SF102 Call Stations: Connect wires as shown in Figure 11 and Figure 12.

SF155B Emergency Stations: Connect wires as shown in Figure 11 and Figure 12.

LI150B Duty Stations: Connect wires as shown in Figure 11 and Figure 12.

LI381 Corridor Lights, LI382 Zone Lights, LI382LED Corridor/Zone Lights: Connect wires as shown in Figure 11 and Figure 12.

PK152, PK151A Power & Control Unit: Connect wires as shown in Figure 11 and Figure 12. Also connect secondary from the SS106 Transformer (24 VAC, 30 VA connec-tions) to the PK152 or PK151A as shown in Figure 11 and Figure 12. Do not connect transformer primary to power source until entire installation is completed and checked for shorts and grounds.

PK800A Secondary Power Supply: Connect wires as shown in Figure 19.

24 VAC 100 VA Transformer: Connect wires as shown in Figure 19. Do not connect transformer primary to power source until entire installation is completed and checked for shorts and grounds.

Connections CheckoutRecheck all connections to equipment. If all wires and connections are satisfactory, connect primary coil of SS106 Transformer to source of 117 VAC 60 cycles (40 watts max.) and operation of system can be checked according to System Test Instructions next in this section.

System Test InstructionsBefore proceeding with a system test, all stations should be set to normal conditions as follows:

NC110A Master Station: No initialization is necessary.

NC110N Master Station: All push buttons should be in normal out position. If depressed, the tone off button may be released by pressing the button and then releasing it.

SF100C, SF102, SF100N, SF100/2 Call Stations: If the call cord push button has been pressed, reset the station by pressing the cancel button.

SF101N, SF101C Call Stations: If the call button has been pressed, reset the station by pressing the cancel button.

SF339, SF153N Emergency Stations: If the call/cancel switch is pressed to the in posi-tion, press the switch again or twist the switch to the out position to reset the station.

SF155B, SF151N Emergency Stations and SF156B Code Station: If the call cord has been pulled or the switch has been pulled down, reset the station by pushing the switch up.

LI150B, LI150N Duty Stations: Push the tone off switch up.

System Installation

IL381 Tek-CARE® NC110 Manual • 13Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Checkout and TestingSF100C, SF100N, SF100/2, SF101C, SF101N, SF102 Call Stations: Test call stations one

at a time. Initiate a call on each station. Press the button on the end of the call cord for SF100C, SF100N, SF100/2, SF102 Call Stations. Press the call button for SF101C, SF101N Call Stations. Check for operation of the following signals:

• The call placed lamp on the call station should be illuminated.• The LI381, LI382 or LI382LED Corridor Light near the room entrance should be

illuminated.• On the NC110N Master Station, the call lamp should be illuminated and the

associated station selector lamp (marked to identify the calling station) should be illuminated. A slowly repeating audible call tone should be heard. The normal call tone may be silenced by the tone off button, which should be illuminated to indicate tone silencing.

• On all LI150B Duty Stations, the call placed lamp should be illuminated, and a slowly repeating audible call tone should be heard. The normal call tone may be silenced by the tone off button.

Reset the call at the call station: Press the cancel button on SF100C, SF100N, SF101C, SF101N and SF102 stations. All signals should be canceled.

SF155B, SF339, SF151N, SF153N Emergency Stations and SF156B Code Station: Test stations one at a time. Initiate a call on each station. Pull the call cord on the SF151N Emergency Station. Push the switch to the in position on the SF339, SF153N Emer-gency Stations. Slide the switch to the down position or pull the call cord on the SF155B Emergency Station. Slide the switch to the down position on the SF156B Code Station. Check for operation of the following signals:

• The call placed lamp should be flashing• The LI381 Corridor Light, LI382 Zone Light and LI382LED Corridor/Zone Light

near the room entrance should be flashing.• On the NC110N Master Station, the call lamp should be flashing, the emergency

lamp should be flashing, and the associated station selector lamp (marked to identify the calling station) should be flashing. An intermittent audible call tone should be heard. Pressing the tone off button must not cancel the emergency call tone.

• On all LI150B Duty Stations, the call lamp should be flashing, and an intermittent audible call tone should be heard. The tone off button must not cancel the emergency call tone.

14 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

System Maintenance Instructions

Most of the equipment and parts used in the Tek-CARE® NC110 Nurse Call System are not user serviceable and cannot be replaced or repaired by the end user. Equipment must be repaired by qualified service personnel only. Parts that are user serviceable are listed in the following sec tion and their replacement explained.

NC110A Master StationsThere are no user replaceable components on the NC110A. Clean the membrane switch with a damp cloth as needed. Check for unintentional button presses which may occur during cleaning.

NC110N Master StationsRefer to Figure 8 to identify replacement parts. A full list of replacement parts and num-

bers appears in the Replacement Parts section.

Selector Lamp Lens Replacement:• Remove lens by squeezing top and bottom together and pulling away from panel.• Replace with same color lens by pushing new lens towards panel. The lens should

snap into place on the selector lamp/switch knob with a noticeable click.

Selector Lamp Filter Identification:• Remove lens by squeezing top and bottom together and pulling away from panel.• Remove white filter by lifting it out of the selector lamp/switch knob.• Identify filter by room number or other means using dry transfer lettering, labels,

or other similar methods. Be sure identified filter is replaced in knob so that lettering is readable right side up.

• Replace lens by pushing it towards panel. The lens should snap into place on the selector lamp/switch knob with a noticeable click.

Figure 8—NC110N Selector Lamp/Switch Lens,

Filter and Lamp Replacement1

2

3

4

1 – Lens2 – Filter3 – 24V Lamp4 – Switch Knob

System Maintenance Instructions

IL381 Tek-CARE® NC110 Manual • 15Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Defective Lamp Replacement:• Remove lens and filter by methods described above.• Using needle-nosed pliers, tweezers or similar tool, pull lamp out of socket by

gripping lamp at sides and moving it from side to side as it is pulled away from the panel. WARNING: Do not squeeze too tightly, or it will break.

• Replace lamp by holding with tool and pushing into socket. Be sure lamp is turned so that the base is lined up with the slot in the socket. Lamp must be pushed in below the level of the filter.

• Push test button to make sure lamp has been placed in socket properly. If lamp does not light, try pressing more firmly into socket. If lamp still does not light, repeat steps above with new lamp until one works properly.

• Replace lens and filter in selector lamp/switch knob as previously described.

PK152, PK151A Power & Control UnitsThere are no user serviceable parts in the PK152 and PK151A Power & Control Units. Notify qualified service personnel for repair or replacement.

PK153 Third Priority Control UnitThere are no user serviceable parts in the PK153 Third Priority Control Unit. Notify qualified service personnel for repair or replacement.

PK800A Secondary Power SupplyThe only user serviceable part is a 4A, 125 VAC fuse (1.25″×0.25″).

• Disconnect power to the associated transformer. If the transformer is hard wired, locate the associated breaker and turn it off. If a means cannot be established to remove power to the transformer, then contact qualified service personnel and do not proceed further. The SS106 powering the associated PK152 or PK151A should also be powered down in the same fashion.

• Once power has been disconnected, firmly grasp the black fuse holder knob on the side of the PK800A, push in and rotate it counterclockwise. Pull out on the knob to expose the fuse.

• Remove the fuse and insert a new fuse. Reinsert fuse holder knob. Restore power to the system.

For repair or replacement of any other parts, contact qualified service personnel. A list of replacement parts and numbers appears in the Replacement Parts section.

4AFast-BlowFuseAssemblyThe only user serviceable part is a 4A, 125 VAC fuse (1.25″×0.25″).

• Disconnect power to the associated transformer. If the transformer is hard wired, locate the associated breaker and turn it off. If a means cannot be established to remove power to the transformer, then contact qualified service personnel and do not proceed further. The SS106 powering the associated PK152 or PK151A should also be powered down in the same fashion.

• Once power has been disconnected, firmly grasp both ends of the fuse holder, push in and rotate in opposite directions. Pull out on both ends to expose the fuse.

• Remove the fuse and insert the new fuse. Put fuse holder back together and verify that both pieces are interlocked. Restore power to the system.

For repair or replacement of any other parts, contact qualified service personnel. A list of replacement parts and numbers appears in the Replacement Parts section.

System Maintenance Instructions

16 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

SF100C, SF100N, SF100/2, SF102 Call StationsThe only user serviceable part on these stations are the call cords. To replace:

• To remove the call cord, grip end of plug firmly and pull straight away from call station.• To replace the call cord, hold by end of plug and push straight into call cord jack

on call station.• To test, push the button at the end of the call cord. The call placed lamp should

illuminate. Push the cancel button to cancel the call.

For repair or replacement of any other parts, contact qualified service personnel. A list of replacement parts and numbers appears in the Replacement Parts section.

SF101C, SF101N Call StationsThere are no user servicable parts on the SF101C, SF101N Call Staions. Notify qualified service personnel for repair department

SF155B,SF339,SF151N,SF153NEmergencyStationsandSF156BCodeStationThere are no user serviceable parts on the SF155N, SF339, SF151N, SF153N Emergency or SF156B Code Stations. Notify qualified service personnel for repair or replacement.

LI150B,LI150NDutyStationsThere are no user serviceable parts on the LI150B, LI150N Duty Stations. Notify qualified service personnel for repair or replacement.

LI381 Corridor and LI382 Zone Lights• To remove cover, grip firmly by sides, and pull cover away from plate.• To remove bulb, make sure that no call is placed, then push bulb in towards plate.

Turn bulb counterclockwise and pull bulb out of socket. On LI382, remove red bulb cover before removing bulb.

• To replace bulb, hold by glass part and push metal end into socket. When resistance is encountered, turn bulb clockwise until it falls into socket. (Metal part should be below the top of the socket.) Push bulb again and turn clockwise until bulb stops turning, and then release. On LI382, replace red bulb cover. Be sure to place bulb cover over the same bulb from which it was removed.

• To test light, place a call at the associated station. If light still does not work, repeat steps above until corridor light and/or corridor zone lights function properly.

• To replace cover, reverse instructions for removal.

Replacement PartsPart No. Description Used ForLI014K 24V Lamp NC110N Control and Selector Module LampsLI028K 28V Lamp LI381 Corridor Lights, LI382 Zone LightsRP021K Blank Filter NC110N Selector Button LabelRP022K Orange Lens NC110N Tone Test Button and Selector ButtonsRP024K Green Lens NC110N Tone Off ButtonRP027K Clear Lens NC110N Emergency ButtonRP028K Yellow Lens NC110N Call ButtonRP037AK Red Bulb Cover LI382 Corridor Zone LightsSF301A Call Cord SF100C, SF100N, SF100/2, SF102 Call StationsSF302 Call Cord Dual SF100C, SF100N, SF100/2, SF102 Call Stations

IL381 Tek-CARE® NC110 Manual • 17Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure9—BlockWiringDiagramwithoutZoneLamps

TRUNK CABLE

TRUNK CABLE3 #18

POINT WIRE1 #22 [per room, home-run to the master]

SYSTEMTO

MASTER

<OVERHEAD VIEW OF HOSPITAL CORRIDOR>

IR

STATIONSERIES

SF

STATIONSERIES

SF

STATIONSERIES

SF

STATIONSERIES

IR

STATIONSERIES

DOMELIGHT

DOMELIGHT

SF

STATIONSERIESDOME

LIGHT

IR

STATIONSERIES

2 #22 plus

DOMELIGHTTRUNK &

POINT WIRE

IR

STATIONSERIES

SF

STATIONSERIESDOME

LIGHT

2 #22 plus

3 #22 plus 4 #22

3 #22 plus 3 #22

3 #22 plus 3 #22 plus 3 #22 plus

3 #18

SF

STATIONSERIES

SF

STATIONSERIES

IR

STATIONSERIESDOME

LIGHT

3 #22 plus 4 #22 plus 3 #22 plus

TRUNK &POINT WIRE

TRUNK &POINT WIRE

MASTER STATION

PK151N / PK151A / PK152POWER/CONTROL UNIT

6 #18

POINTWIRES

TRUNK(3 #18)

SS106TRANSFORMER

2 #18

POINT WIRE

POINT WIRE

POINT WIRE

POINT WIRE POINT WIRE POINT WIRE

POINT WIRE

100' MAX.

Drawing Name & Number: IL381 NC110N Block Diagram 1 Rev0 062614

POINT WIRE

TRUNK &POINT WIRE

TRUNK &POINT WIRE

TRUNK &POINT WIRE

POINT WIRE

POINT WIRE POINT WIRE

Maximum 15 corridor lights, 16 stations and 500' per run.

18 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure 10—BlockWiringDiagramwithZoneLamps

TRUNK CABLE

TRUNK CABLE5 #18 (3 #18 + 2 #18 for zone pair)

POINT WIRE1 #22 [per room, home-run to the master]

SYSTEM

ZONELAMP

(The two additional conductors extend from ZONE lamp through corridor.)

TO

MASTER

<OVERHEAD VIEW OF HOSPITAL CORRIDOR>

IR

STATIONSERIES

SF

STATIONSERIES

SF

STATIONSERIES

SF

STATIONSERIES

IR

STATIONSERIES

DOMELIGHT

DOMELIGHT

SF

STATIONSERIESDOME

LIGHT

IR

STATIONSERIES

3 #22 plus

DOMELIGHTTRUNK &

POINT WIRE

IR

STATIONSERIES

SF

STATIONSERIESDOME

LIGHT

3 #22 plus

5 #22 plus 5 #22

5 #22 plus 4 #22

5 #22 plus 4 #22 plus 4 #22 plus

3 #183 #18

5 #18

ONE TRUNK COMMON, "P" PLUSTWO ZONE LIGHT COMMONS

These conductors are common to all rooms <NOT individual home-runs>.

SF

STATIONSERIES

SF

STATIONSERIES

IR

STATIONSERIESDOME

LIGHT

5 #22 plus 6 #22 plus 4 #22 plus

TRUNK &POINT WIRE

TRUNK &POINT WIRE

MASTER STATION

PK151N / PK151A / PK152POWER/CONTROL UNIT

6 #18

POINTWIRES

TRUNK(3 #18)

SS106TRANSFORMER

2 #18

POINT WIRE

POINT WIRE

POINT WIRE

POINT WIRE POINT WIRE POINT WIRE

POINT WIRE

100' MAX.

NC110N Wiring Diagram with Zone Lamps

Drawing Name & Number: IL381 NC110N Block Diagram 2 Rev0 062614

Maximum 15 corridor lights, 16 stations and 500' per run.

POINT WIRE

TRUNK &POINT WIRE

TRUNK &POINT WIRE

TRUNK &POINT WIRE

POINT WIRE

POINT WIRE POINT WIRE

IL381 Tek-CARE® NC110 Manual • 19Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 1

1—N

C11

0A W

irin

g D

iagr

am

J D R R P T1 N Q E

P L R P F VQ LY

G P F V Q L

P Y L R

Red

Whi

te

R PCo

mm

onW

ires

Q

SF15

1N/S

F153

N

See

Note

1

NO. 2

2

SS10

6

PK15

1N/A

PL11

6

NC11

0A

ENCL

OSU

REEQ

UIPM

ENT

CENT

RAL

LI38

1

N Q

J D P E

SF10

0N &

SF1

00/2

LI38

1

SF10

0N/S

F101

N/10

0/2

NOTE

S1.

Use

18

gaug

e wi

re fo

r opt

iona

l LI3

82, L

I382

LED

Corri

dor Z

one

Ligh

t wiri

ng.

2. M

ain

supp

ly cir

cuit:

con

nect

to 1

17 V

AC, 6

0 Hz

(40

watts

max

.).

U

se 1

8 ga

uge

wire

min

imum

. SS1

06 T

rans

form

er ra

ting

is 24

VAC

, 30

VA m

inim

um.

3. T

erm

inal

iden

tifica

tions

sho

wn a

re n

ot in

act

ual o

rder

.4.

All c

o mm

on w

ires

18 g

auge

. Al

l oth

er w

ires

22 g

auge

.

24 V

AC, 6

0 Hz

. 1.2

5 Am

ps

NO. 1

8

NO. 1

8

LI38

2, L

I382

LED

SF15

1NSF

153N

G

LI38

1

5. W

ire c

olor

s do

not

app

ly to

"N" v

ersio

ns o

f sta

tions

.

T2P

SF10

0B, S

F100

C, S

F101

C &

SF10

2

SF15

5B

LI38

1

LI38

1LI

381

SF15

5B

BRO

WN

(P)

RED

(R)

ORA

NGE

(N.U

.)

YELL

OW

(N.U

.)

GRE

EN (Y

)BL

UE (L

)

BRO

WN

(P)

RED

(R)

ORA

NGE

(N.U

.)

YELL

OW

(N.U

.)

GRE

EN (Y

)BL

UE (L

)BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)BL

UE (N

.U.)

BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)

BLUE

(N.U

.)

LI15

0N/L

I150

B

Stan

d Al

one

Conf

igur

atio

nSt

and

Alon

e Co

nfig

urat

ion

Stan

d Al

one

Conf

igur

atio

nSt

and

Alon

e Co

nfig

urat

ion

Com

bine

d Co

nfig

urat

ion

Com

bine

d Co

nfig

urat

ion

Powe

r/Con

trol u

nit

SF10

0B/1

00C/

102

BLUE

N.O

. DRY

CO

NTAC

TCA

LL O

U TPU

TM

AX. 2

8V, 1

A NO

N-PU

L SAT

ING

SEE

NOTE #2

OR

ANG

E (4

)

RED

(8)

WHI

TE (7

)

BRO

WN

(2)

GR

EEN

( 3)

VIO

LET

BLAC

K (1

)

(5)

(6)

111

2131

412 3 4 5 6 7 8 9 10

12 13 14 15 16 17 18 19 20

22 23 24 25 26 27 28 29 30

32 33 34 35 36 37 38 39 40

42 43 44 45 46 47 48 49 50

CONN

ECTO

RG

ROUP

ING

BRO

WN

ORA

NGE

GRE

ENYE

LLO

WVI

OLE

TRE

DG

RAY

BLAC

KW

HITE

BLUE

COLO

RW

IRE

MAS

TER

STAT

ION

KEYP

AD C

OLU

MN

LAYO

UT

or P

K152

24 V

AC, 6

0 Hz

. 1.2

5 Am

ps

IL38

1 NC

110A

Wiri

ng D

iagr

am R

ev3

0303

11 1

Zone

Lig

ht

ELEC

TRIC

AL R

ATIN

GS

(MAX

IMUM

)NC

110A

PK15

1N/A

SF10

0N/C

SF10

1N/B

SF15

1N

SF15

5BSF

153N

LI15

0N/B

LI38

1LI

382

Mas

ter S

tatio

nPo

wer/C

ontro

l Uni

t

Call S

tatio

nCa

ll Sta

tion

Emer

genc

y St

atio

n

Duty

Sta

tion

Corri

dor L

ight

Emer

genc

y St

atio

n

Corri

dor Z

one

Ligh

t

24 V

DC, .

36 A

mps

24 V

DC, .

09 A

mps

24 V

DC, .

03 A

mps

24 V

DC, .

03 A

mps

24 V

DC, .

03 A

mps

24 V

DC, .

068

Amps

Emer

genc

y St

atio

n24

VDC

, .03

Am

ps

SF10

2Ca

ll Sta

tion

24 V

DC, .

09 A

mps

24 V

DC, .

09 A

mps

24 V

DC, .

06 A

mps

PK15

2Po

wer/C

ontro

l Uni

t

LI38

2LED

Corri

dor Z

one

Ligh

t24

VDC

, .08

Am

ps

PK80

0ASe

cond

ary

Powe

r Sup

ply

24 V

AC, 6

0 Hz

1 250

8 6

4 2

7 5

3 1

(BAC

K O

F PL

ATE)

20 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 1

2—N

C11

0N W

irin

g D

iagr

am

JD

EE1

LL

LL

NN

J D R R P T1 N Q E

P

P L R P F VQ LY

G P F V Q L

P Y L R

Red

Whi

te

R PCo

mm

onW

ires

Q

SF15

1N/S

F153

N

See

Note

1

NO. 2

2

SS10

6

PK15

1N/A

/ PK

152

See

Not

e2

ENCL

OSU

REM

ASTE

R ST

ATIO

NNC

110N

ENCL

OSU

REEQ

UIPM

ENT

CENT

RAL

SELE

CTO

R M

OD

ULE

TERM

INAL

MO

DULE

LI38

1

N Q

J D P E

SF10

0N &

SF1

00/2

LI38

1

SF10

0N/S

F101

N/10

0/2

NOTE

S1.

Use

18

gaug

e wi

re fo

r opt

iona

l LI3

82, L

I382

LED

Corri

dor Z

one

Ligh

t wiri

ng.

2. M

ain

supp

ly cir

cuit:

con

nect

to 1

17 V

AC, 6

0 Hz

(40

watts

max

.).

U

se 1

8 ga

uge

wire

min

imum

. SS1

06 T

rans

form

er ra

ting

is 24

VAC

, 30

VA m

inim

um.

3. T

erm

inal

iden

tifica

tions

sho

wn a

re n

ot in

act

ual o

rder

.4.

All c

o mm

on w

ires

18 g

auge

. Al

l oth

er w

ires

22 g

auge

.

ELEC

TRIC

AL R

ATIN

GS

(MAX

IMUM

)NC

110N

Mas

ter S

tatio

n24

VDC

, .36

Am

ps

NO. 2

2

NO. 1

8

NO. 1

8

SF15

1NSF

153N

G

LI38

1

5. W

ire c

olor

s do

not

app

ly to

"N" v

ersio

ns o

f sta

tions

.

T2P

P

SF10

0B, S

F100

C

SF15

5B

LI38

1

LI38

1LI

381

SF15

5B

LL

LL

BRO

WN

(P)

RED

(R)

ORA

NGE

(N.U

.)

YELL

OW

(N.U

.)

GRE

EN (Y

)BL

UE (L

)

BRO

WN

(P)

RED

(R)

ORA

NGE

(N.U

.)

YELL

OW

(N.U

.)

GRE

EN (Y

)BL

UE (L

)BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)BL

UE (N

.U.)

BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)

BLUE

(N.U

.)

LI15

0N/L

I150

B

Stan

d Al

one

Conf

igur

atio

nSt

and

Alon

e Co

nfig

urat

ion

Stan

d Al

one

Conf

igur

atio

nSt

and

Alon

e Co

nfig

urat

ion

Com

bine

d Co

nfig

urat

ion

Com

bine

d Co

nfig

urat

ion

Powe

r/Con

trol u

nit

Cont

rol M

odul

e

SF10

0B/1

00C/

102

SF10

1C &

SF1

02

IL38

1 NC

110N

Wire

1 Re

v6 0

3031

1 1

24 V

AC, 6

0 Hz

. 1.2

5 Am

ps24

VAC

, 60

Hz. 1

.25

Amps

PK15

1N/A

SF10

0N/C

SF10

1N/B

SF15

1N

SF15

5BSF

153N

LI15

0N/B

LI38

1LI

382

Powe

r/Con

trol U

nit

Call S

tatio

nCa

ll Sta

tion

Emer

genc

y St

atio

n

Duty

Sta

tion

Corri

dor L

ight

Emer

genc

y St

atio

n

Corri

dor Z

one

Ligh

t

24 V

DC, .

09 A

mps

24 V

DC, .

03 A

mps

24 V

DC, .

03 A

mps

24 V

DC, .

03 A

mps

24 V

DC, .

068

Amps

Emer

genc

y St

atio

n24

VDC

, .03

Am

ps

SF10

2Ca

ll Sta

tion

24 V

DC, .

09 A

mps

24 V

DC, .

09 A

mps

24 V

DC, .

06 A

mps

PK15

2Po

wer/C

ontro

l Uni

t

LI38

2LED

Corri

dor Z

one

Ligh

t24

VDC

, .08

Am

ps

PK80

0ASe

cond

ary

Powe

r Sup

ply

24 V

AC, 6

0 Hz

LI38

2, L

I382

LED

Zone

Lig

ht

IL381 Tek-CARE® NC110 Manual • 21Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 1

3—N

C15

0N, N

C20

0N, T

wo

Sta

tions

in P

aral

lel

Switc

h M

odul

e

UN

JE

J D R R P T1 Q E

Red

Whi

te

RCo

mm

onW

ires

QSee

SS10

6

TALK

/LIS

TEN

Mas

ter S

tatio

n En

closu

reNC

150N

/200

NCe

ntra

l Equ

ipm

ent

SELE

CTO

R M

OD

ULE

TER

MIN

A L M

OD

ULE

N Q

J D P E

IR15

0N/1

51N/

152N

/153

N/15

5N

NOTE

S1.

Sel

ecto

r swi

tch

mod

ule

show

n is

repr

esen

tativ

e of

NC1

50N

mas

ter s

tatio

n.

3. M

ain

supp

ly cir

cuit:

Con

nect

to 1

17 V

AC, 6

0 Hz

(40

watts

max

.). U

se 1

8 ga

uge

wire

min

imum

.

SS1

06 T

rans

form

er ra

ting

is 2

4 VA

C, 3

0 VA

min

imum

.

2. T

erm

inal

iden

tifica

tions

sho

wn a

re n

ot in

act

ual o

rder

.

4. U

se s

hiel

ded

cabl

e if

not i

n a

met

al c

ondu

it. If

shi

elde

d ca

ble

is us

ed, s

hiel

d wi

re re

plac

es

No. 2

2

No. 1

8

No. 1

8

LI38

2, L

I382

LED

T2PSF

155B

LI38

1

BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)BL

UE (N

.U.)

P YC XRP L YC XR

C

CD

PP1

No. 1

8

LL

XL

LX

LL

XL

LX

XXX

X

cond

ucto

r con

nect

ed to

ter

min

al C

on

talk

/Lis

ten

mod

ule

on N

C150

N.5.

Use

18

gaug

e wi

re fo

r opt

iona

l LI3

82, L

I382

LED

zone

lIgh

t wiri

ng.

Shie

lded

, See

Not

e 4 Cha

ssis

gro

und

Note

5

LI15

0N/L

I150

B

Com

bine

d Co

nfig

urat

ion

Com

bine

d Co

nfig

urat

ion

IR15

0N/1

51N/

152N

/153

N/15

5N

NOTE

: Dio

des

are

1N40

03 ty

pe.

IL38

0 IL

381

NC15

0N N

C200

N 2

Stat

ions

Par

alle

l Rev

5 03

0311

1

Enclo

sure

See

Note

3

P

N

L

PK15

1N /

PK15

1A /

Powe

r & C

ontro

l Uni

tPK

152

Zone

Lig

ht

22 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure 14—NC110A Housing Installation Diagram

Figure 15—PL116 Wall Plate Wiring Diagram

NC110A TYPICAL INSTALLATION REV0 112806 1

CABLES GATHERED AND TIEDWHERE APPROPRIATE

WALL PLATE

NC110A

DESK

TO PK151

TO FIELD

PL116 REAR VIEW

IL381 PL116 REAR VIEW REV1 082812

IL381 Tek-CARE® NC110 Manual • 23Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Notes:

1. Main supply circuit, connect to 117 VAC, 60Hz (40 watts max). Use #18 gauge wire minimum. SS106 transformer rating is 24 VAC, 30VA maximum.

2. Terminal identifications shown are not in actual order.

3. All common wires are #18 gauge. All other wires are #22 gauge.

4. The secondary PK151A or PK152 uses terminals P (power to second master) and N (common) only. All other functions are supplied by the primary PK151A or PK152.

Figure 16—NC110N Second Master Wiring Diagram

Central EquipmentEnclosure

NC110NSecond Master Station

Enclosure

NC110NMaster Station

Enclosure

ControlModule

SS106

PK151A / PK152

24 VACSelector ModuleTerminal Module

N N P P

L L L L

N N P P

L L L L

J D E E1J D E E1

JD

RRPPT1T2NNQ

QE

Rev.0•10/07/96•MELRev. 1 • 05/24/10 • RLTRev. 2 • 10/05/10 • RLT

24 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 1

7—P

K15

3 W

irin

g D

iagr

am

JD

EE1

LL

LL

NN

P

ENCL

OSU

REM

ASTE

R ST

ATIO

NNC

110N

ENCL

OSU

REEQ

UIPM

ENT

CENT

RAL

SELE

CTO

R M

ODU

LE

TERM

INAL

MO

DULE

P

LL

LL

Cont

rol M

odul

e

J D R R P T1 N Q E

24VA

C SS

106

PK15

1N/A

/ PK

152

N QT2P

Powe

r/Con

trol u

nit

E2 D2 E1 D1 P1 P N J1 J2

PK15

3 P1

Cont

rol u

nit

E J PD

LI15

0N

V

LI15

0B

V R P Q

SF15

5B LI38

1

BROW

N (P

)RE

D (R

)OR

ANGE

(N.U

.)

YELL

OW (N

.U.)

GREE

N (Y

)BL

UE (L

)

BROW

N (P

)

RED

(Q)

ORAN

GE (F

)

YELL

OW (V

)

GREE

N (L

)BL

UE (N

.U.)

N.O

.N.

C.

Smok

e De

tect

or

NOTE

S:1.

Thi

s dr

awin

g is

a su

pple

men

t to

the

stan

dard

NC1

10N

wirin

gdi

agra

m a

nd w

iring

not

es.

2. T

he N

C110

N pr

ovid

es a

ncilla

ry a

nnun

ciatio

n on

ly of

fire

sig

nals.

SF10

0B, S

F100

C,Co

mbi

ned

Conf

igur

atio

n

SF10

1C, S

F102

SF15

5B LI38

1

BROW

N (P

)RE

D (R

)OR

ANGE

(N.U

.)

YELL

OW (N

.U.)

GREE

N (Y

)BL

UE (L

)

BROW

N (P

)

RED

(Q)

ORAN

GE (F

)

YELL

OW (V

)

GREE

N (L

)BL

UE (N

.U.)

SF10

0B, S

F100

C,Co

mbi

ned

Conf

igur

atio

n

SF10

1C, S

F102

SF10

0B, S

F100

C,

SF15

5B

LI38

2

BROW

N (P

)RE

D (R

)OR

ANGE

(N.U

.)

YELL

OW (N

.U.)

GREE

N (Y

)BL

UE (L

)

BROW

N (P

)

RED

(Q)

ORAN

GE (F

)

YELL

OW (V

)

GREE

N (L

)BL

UE (N

.U.)

Com

bine

d Co

nfig

urat

ion

N.O

.

N.O

.N.

C. WHI

TE

RED

Smok

e De

tect

or

SF10

1C, S

F102

BROW

N (P

)

RED

(Q)

ORAN

GE (F

)

YELL

OW (V

)

GREE

N (L

)BL

UE (N

.U.)

SF15

5B

IL38

1 PK

153

Wire

1 Re

v4 0

3031

1 1

LI38

2LED

IL381 Tek-CARE® NC110 Manual • 25Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 1

8—PK153WiringDiagram

withSF156BCodeStation

JD

EE1

LL

LL

NN

P

ENCL

OSU

REM

ASTE

R ST

ATIO

NNC

110N

ENCL

OSU

REEQ

UIPM

ENT

CENT

RAL

SELE

CTO

R M

ODU

LE

TERM

INA L

MO

DULE

P

LL

LL

Cont

rol M

odul

e

J D R R P T1 N Q E

24VA

C SS

106

N QT2P

Powe

r/Con

trol u

nit

E2 D2 E1 D1 P1 P N J1 J2

PK15

3 P1

Cont

rol u

nit

E J PD

LI15

0N

V

P L R P F VQ LYSF10

0N &

SF1

00/2

LI38

1

SF15

1N/1

53N

GCom

bine

d Co

nfig

urat

ion

LI15

0B

V R P Q

SF10

1C, S

F102

SF15

5B LI38

1

BRO

WN

(P)

RED

(R)

ORA

NGE

(N.U

.)

YELL

OW

(N.U

.)

GRE

EN (Y

)BL

UE (L

)

BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)BL

UE (N

.U.)

Com

bine

d Co

nfig

urat

ion

BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)BL

UE (N

.U.)

P F VQ LGSF

156

LI38

1

Smok

e De

tect

or

SF15

6B

BRO

WN

(P)

RED

(Q)

ORA

NGE

(F)

YELL

OW

(V)

GRE

EN (L

)BL

UE (N

.U.)

SF15

6B

LI38

1

Stan

d Al

one

Conf

igur

atio

nSt

and

Alon

e Co

nfig

urat

ion

NOTE

S:1.

Thi

s dr

awin

g is

a su

pple

men

t to

the

stan

dard

NC1

10N

wirin

g N

C110

N wi

ring

diag

ram

and

wiri

ng n

otes

.

2. T

he N

C110

N pr

ovid

es o

nly

ancil

lary

ann

uncia

tion

of fi

re s

igna

ls.N.

O.

N.C.

PK15

1A /

PK15

2

SF10

0B, S

F100

C,

26 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure19—

PK

152

or P

K15

1A to

PK

800A

Inte

rcon

nect

ion

J D R R P T1 N Q E

24VA

C SS

100

PK80

0A

N QT2P

Powe

r sup

ply

PK15

1A /

PK1

52Co

ntro

l uni

t

Fuse

Ass

y.

Mou

nt w

ithin

2 fe

et o

f eac

h ot

her.

Note:

T1 a

nd T

2 in

puts

whe

n in

terc

onne

ctin

g PK

800A

Seco

ndar

y Po

wer S

uppl

y!

Do n

ot c

onne

ct S

S106

Tra

nsfo

rmer

to P

K151

A/PK

152

Gro

und

Gro

und

Gro

und

Gro

und

24VA

C

24VA

C

24VD

C

24VD

C

24VD

C

5VDC

5VDC

5VDC

To m

aste

r

To fi

eld

IL38

1 PK

151A

PK8

00A

Inte

rcon

nect

ion

Rev5

030

111

J D E P N R Q P

4A F

ast-B

low

INLI

NE

All w

iring

sho

wn is

18-

gaug

e.

IL381 Tek-CARE® NC110 Manual • 27Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 2

0—SF337CCrossReferenceDiagram

Brow

nRe

dO

rang

eYe

llow

Gre

enBl

ue

on s

tatio

n

P Not u

sed

Q QLV

7 pi

n co

nnec

tor

Purp

leF NO

TE: B

oth

jum

pers

on

back

of s

tatio

nne

ed to

be

in u

p po

sitio

n!

DRAW

ING

#: IL

380

IL38

1 SF

337C

WIR

ING

REV

1 09

1603

1

EMER

GEN

CY

Note

: Bot

h O

rang

e &

Blue

wire

s ar

e co

nnec

ted

to "Q

" com

mon

an

d m

ust b

e co

nnec

ted

toge

ther

.

28 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 2

1—SF339CrossReferenceDiagram

Brow

nRe

dO

rang

eYe

llow

Gre

enBl

ue

on s

tatio

n

P Not u

sed

Q QLV

7 pi

n co

nnec

tor

Purp

leF NO

TE: B

oth

jum

pers

on

back

of s

tatio

nne

ed to

be

in u

p po

sitio

n!

Brow

nRe

dO

rang

eYe

llow

Gre

enBl

ue

on s

tatio

n

P Not u

sed

Q QLV

7 pi

n co

nnec

tor

Purp

leF NO

TE: B

oth

jum

pers

on

back

of s

tatio

nne

ed to

be

in u

p po

sitio

n!

DRAW

ING

#: IL

380

IL38

1 SF

339

WIR

ING

REV

3 09

1603

1

Note

: Bot

h O

rang

e &

Blue

wire

s ar

e co

nnec

ted

to "Q

" com

mon

an

d m

ust b

e co

nnec

ted

toge

ther

.

IL381 Tek-CARE® NC110 Manual • 29Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figure 22—NC110N Hookup to NC150N, NC200N

MODULE

J D E E1

L L L L

N N P P

CONTROL

ENCLOSUREMASTER STATION

NC110N

SELECTOR MODULE

TERMINAL MODULE

D

J

E

NPK151A / PK152

L

L

L

TOSELECTIVE LAMP

WIRE ONNC150N, NC200N

NC150N, NC200NTO

PK151A / PK152NC110NTO

N

P

IL381 NC110N NC150N NC200N Hookup Rev2 100110 1

#22

#18

#18

PK and NC150N/NC200Nmust not exceed 100'.

Total wire distance between

30 • IL381 Tek-CARE® NC110 Manual Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Figu

re 2

3—S

F157

and

SF1

57/2

Wir

ing

Dia

gram

1

1P

2Y

Conn

ectio

ns to

3L

4R N P F

To M

aste

r "L"

V L Q

SF15

1N/

SF15

7

SF15

7/2

2 3 4

1 2 3 4P Y L R N

P Y L R N

To M

aste

r "L"

P Co

mm

o

R Co

mm

Q C

omm

N Co

mm

To P

K15

TV o

utpu

ts

SF15

3N

Conn

ectio

ns to

TV o

utpu

tsCo

nnec

tions

to

LI38

1Do

me

Ligh

t

*Not

e - O

rder

of t

erm

inal

s ha

s be

en c

hang

ed fo

r dra

wing

pur

pose

s.

Pillo

w Sp

eake

r Wiri

ng

1 - T

V Sw

itch

2 - T

V Sw

itch

and

TV A

udio

Com

mon

3 - T

V Au

dio

To Z

one

Lam

p R

edBu

lb

To Z

one

Lam

p W

hite

Bulb

LI38

1Do

me

Ligh

t

TV o

utpu

ts