HF-Performer III for PL-T/C lampsHF-P 226 PL-T/C III 220-240V 50/60Hz
HF-Performer III PL-T/C is a sustainable, slim and high-frequency electronic ballast for PL-T and PL-C fluorescentlamps. It is ideal for applications where high energyefficiency is required. The HF-Performer III range has arobust design, meets all relevant international safety andperformance standards and is energy efficient (CELMA EEIA2).
Product data
• General InformationApplication Code IIILamp Type PL-T/CNumber Of Lamps 2 piece/unitNumber Of ProductsOn MCB (16A TypeB) (Nom)
28
Automatic Restart Yes
• Operating and ElectricalInput Voltage 220 to 240 VInput Frequency 50/60 HzOperating Frequency(Max)
- kHz
Operating Frequency(Min)
42 kHz
Operating Frequency(Nom)
45 kHz
Ignition Method Warm StartCrestfactor (Max) 1.7Power Factor 100%Load (Nom)
0.95
Ignition Time (Max) 0.65 sMains VoltagePerformance (AC)
-8%/+6%
Mains Voltage Safety(AC)
-10%/+10%
Earth LeakageCurrent (Nom)
0.5 mA
Inrush CurrentWidth
0.250 ms
Constant WattageDeviation
-2%/+2%
Ballast Factor (Nom) 1Power Losses (Nom) 4.25-3.59 W
Inrush Current Peak(Max)
18 A
• WiringConnector TypeInput Terminals
Insert
Cable CapacityOutput Wires Mutual(Nom)
100 pF
Connector TypeOutput Terminals
Insert
Cable Length FromDevice To Lamp
1 m
Cable Length HotWiring
1 m
Wire Striplength 8.5-9.5 mmDual Fixture Master/Slave
Not applicable [ Master/Slave oper.not applicable]
Input Terminal CrossSection
0.50-1.50 mm²
Output TerminalCross Section
0.50-1.50 mm²
Cable CapacityOutput Wires ToEarth (Nom)
100 pF
• System characteristicsRated Ballast-LampPower
26 W
Rated Lamp PowerOn PL-T/C
26 W
System Power OnPL-T/C
30.3 W
Power Loss On PL-T/C
4.3 W
Lamp Power On PL-T/C
26 W
• TemperatureT-Ambient (Max) 50 °CT-Ambient (Min) -25 °CT-Storage (Max) 80 °CT-Storage (Min) -40 °CT-Case Lifetime(Nom)
75 °C
T-Case Maximum(Max)
75 °C
T-Ignition (Max) 50 °CT-Ignition (Min) -25 °C
• Mechanical and HousingHousing S 103x67x30
• Emergency OperationNominal LightOutput After 60Seconds
100% of EBLF
Battery Voltage LampIgnition
198-254 V
Normal OperatingVoltage (DC)
220-240 V
Battery Voltage LampOperation
176-254
Battery VoltageGuaranteed Opera-tion
176-275 V
Battery VoltageGuaranteed Ignition
186-275 V
Nominal LightOutput After 5Seconds
50% of EBLF
• Approval and ApplicationEnergy EfficiencyIndex
A2
EMI 9 kHz ... 30 MHz EN55015Safety Standard IEC 61347-2-3PerformanceStandard
IEC 60929
Quality Standard ISO 9000:2000EnvironmentalStandard
ISO 14001
Harmonic CurrentEmission Standard
IEC 61000-3-2
Emc ImmunityStandard
IEC 61547
Vibration Standard IEC 68-2-6 FcBumps Standard IEC 68-2-29 EbHumidity Standard EN 61347-2-3 clause 11TemperatureMarking
Yes
Emergency Standard IEC 60598-2-22Hum And NoiseLevel
Inaudible
• Product DataFull product code 872790083423900Order product name HF-P 226 PL-T/C III 220-240V
50/60HzEAN/UPC - Product 8711500881052Order code 913700648866Numerator - Quan-tity Per Pack
1
Numerator - Packsper outer box
12
Material Nr. (12NC) 913700648866Net Weight (Piece) 0.130 kg
Dimensional drawing
A1
A2
B2
B1
C1
D1
HF-P 226 PL-T/C III 220-240V 50/60HzProduct D1 C1 A1 A2 B1 B2
HF-P 226 PL-T/C III 220-240V 50/60Hz 4.2 mm 30.0 mm 103.8 mm 93.5 mm 67.8 mm 57.5 mm
HF-Performer III for PL-T/C lamps
2015, December 24data subject to change
Dimensional drawing
1
234567
HF
BALLAST
8
9
10
L
N
HF-Performer III for PL-T/C lamps
© 2015 Koninklijke Philips N.V. (Royal Philips)All rights reserved.
Specifications are subject to change without notice. Trademarks are the property ofKoninklijke Philips N.V. (Royal Philips) or their respective owners.
www.philips.com/lighting