taylor devices, inc. building today since 1955 for tomorrow

10
Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Upload: claude-johns

Post on 19-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Taylor Devices, Inc.Taylor Devices, Inc.

Building TodayBuilding Today

Since 1955Since 1955

For TomorrowFor Tomorrow

Page 2: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Taylor Dampers Protect Wood Frame Structures from Earthquakes

• Reduce shaking by 2/3.• Install easily inside studding• Adds around 1% to the total cost of a new

house if nothing else changes. Possible overall cost savings with optimum design!

• Retrofit for $6 to $8 per square foot.• Cosmetic damage only after a major

earthquake.

Page 3: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Toggle Brace Damper

Page 4: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Damper Installed

Page 5: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Why Customers Want Dampers

• Earthquake insurance premiums are skyrocketing.

• Deductibles are $60,00 to $100,000 or more, so protection is diluted.

• Insurance doesn’t cover a great deal of the non-structural loss.

• Retrofit with dampers provides an attractive alternate to earthquake insurance.

• People want safety, provided it is affordable.

Page 6: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Experimental Results• MCEER Earthquake Research Center, State

University of New York

• We have recently completed experimental tests using a toggle-braced damper configuration. A preliminary review of the data indicates that, for strong earthquake loading, the walls that were retrofitted with dampers experienced about 1/3 the displacement demand of conventional walls, the conventional walls being near collapse and the damped walls having minor damage.

Page 7: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Toggle Brace Used for the Tests

Page 8: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

Toggle Brace Installed

Page 9: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

How We Work With You

• Arrange for structural engineering review.• Provide toggle brace dampers as required to

the job site. Available from stock.• Supervise initial installation and train your

people to install.• Inspect after installation.

Page 10: Taylor Devices, Inc. Building Today Since 1955 For Tomorrow

The Bottom Line

• You can charge more for structures with built-in earthquake protection.

• You can significantly increase your profit by offering dampers as an option.

• You will have a competitive edge.