table of contents - genstartech manifold syste… · 6 features single manifold systems 5300 series...
TRANSCRIPT
TABLE OF CONTENTS
Dual Manifold Systems
Single-Side Manifold Systems
Single Manifold Systems
Semi-Automatic Manifold Systems
Automatic Manifold Systems
Digital Automatic Manifold Systems
Semi-Automatic Manifold Systems for Liquid Vessel
Semi-Automatic Manifold Syetems for Dual Liquid Vessels
Single-Side & Dual Manifolds without Cylinder Header
Semi-Automatic Manifolds without Cylinder Header & Manifold Cylinder Header
Station Drops
Header Extensions, Valves & Accessories
Pigtails, Wall mounts, Pipe Holders / Supports
Flashback Arrestors
Flashback Arrestors, Pressure Switches & Alarms
Flashback Arrestors, Quick Connectors & Flowmeters
Manifold Regulators
Station & Line Regulators
Manifold Purchase Specifications Form 2
1
Manifold Systems3
4-5
6-7
8-9
10-11
12-13
14-15
16
17
18
19
20
21
22
23
24
25
26
27
www.genstartech.com
TABLE OF CONTENTS
Manifold Accessories
Warranty Information
1 Application of the manifold system: =� Industrial � Specialty Gas � Others
2 Gas service: � Oxygen ==� Acetylene � Propane ==� Air
� Carbon Dioxide (CO2)===� Inert Gases (Argon, Nitrogen, Helium) ==� Others
3 Type of manifold system required: � Manual==� Semi-Automatic= =� Automatic
4 Outlet pressure required: (PSI)
5 Outlet flow rate required: (SCFH)
6 Type of mounting: =� Wall Mount ==� Floor Mount
7 Cylinder Spacing (Center to Center): =� 5” ==� 10” � 13” ==� 18”
8 Number of cylinders required: Left Bank , Right Bank
9 Manifold system layout:
10 Accessories:
Pressure Switch Model No. Qty
Alarm System Model No. Qty
Gas Terminal (Pipeline) Model No. Qty
Gas Heater* Model No. Qty
Others Model No. Qty
*: Optional 500 SCFH heater is available for CO2 & N2O gas service with withdrawal rates above 35 SCFH / cylinder.
Note: Please fill out the above form so GENTEC can recommend the most suitable manifold system
for your application. Please do not hesitate to contact us for more information.
APPLICATION FORM
2
Manifold Purchase Specifications Form
www.genstartech.com
2 "L" shape Layout
4 Crossover Layout
5 Staggered Layout
1 Standard Layout
5200 Series
3 "U" shape Layout
5300/5400/5500/5500D SeriesSeries No.Layout
Manifolds
Cylinder
5600 Series
Ordering Information
Please specify the "model number" when ordering. For example: 5100X indicates a dual “oxygen” manifold
system.
Dual Manifold Systems
��Silver brazing on piping joints for maximum leak prevention.
��Individual Header Valves.
��Wall mount installation only.
Features
��24" flexible high pressure stainless steel braided pigtails with
check valve, Rigid copper pigtails are available as an option.
Pigtails for acetylene models are equipped with dry flashback
arrestor.
��For Acetylene or Fuel gas model, regulator outlet is equipped
with a dry flashback arrestor (FA30PF) for additional safety.
��Gentec's high flow regulator series 153M.
��Relief valve at outlet for protecting downstream piping.
DUAL MANIFOLD SYSTEMS
3
Standard Construction
www.genstartech.com
MODELNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
5100X5100Y5100F5100C5100IN5100Q5100BQ
3000
400
400
3000
3000
3000
3000
10~200
2~15
5~125
5~125
10~200
10~200
10~200
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA510
PIGTAIL, CGA510
PIGTAIL, CGA320
PIGTAIL, CGA580
PIGTAIL, CGA590
PIGTAIL, CGA346
5100 series dual manifold system is a simple gas delivery system which provides a maximum of 2 cylinders in
service at one time . This non-extendable system is suitable for maintenance and simple gas applications or
one cylinder in service at one time and one in reserve where a manual change over is required.
��Open-style manifold.
��System can be designed for right or left-hand direction cylinder bank.
��Silver brazing on piping joints for maximum leak prevention.
��System is designed to accomodate future expansion needs.
��Pressure switch port is available.
��Wall or stand mount are available.
Single-Side Manifold Systems
��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are available
as an option. Pigtails for Acetylene models are equipped with a dry flashback arrestor.
��For Acetylene or fuel gas model, regulator outlet is equipped with a dry flashback arrestor (FA30PF) for
additional safety. As an option, hydraulic flashback arrestors are available for an additional
charge.
��Gentec's high flow regulator series 155M.
��Relief valve at outlet for protecting downstream piping.
SINGLE-SIDE MANIFOLD SYSTEMS
4
5200 series single-side manifold system is designed for a single source of gas supply from one cylinder bank.
Although this system can be used as a main delivery system, it is typically used in industrial and medical
applications as a high pressure emergency back-up system for liquid vessel or bulk systems.
Features
Standard Construction
SERIESNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
5200X5200Y5200F5200C5200IN5200Q5200BQ
3000
400
400
3000
3000
3000
3000
10~200
2~15
5~125
5~125
10~200
10~200
10~200
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA510
PIGTAIL, CGA510
PIGTAIL, CGA320
PIGTAIL, CGA580
PIGTAIL, CGA590
PIGTAIL, CGA346
www.genstartech.com
"L" shape Layout
Crossover Layout
Staggered Layout
Standard Layout
Type of MountingCylinder Spacing(Center to Center)
Example: 5212X-3R-1 indicates a 3 cylinder right-handed simplex oxygen manifold system. Distance between
each cylinder is 10" on standard horizontal layout.
Ordering Information
Please follow the instructions below to select the correct
model number.
Manifold System Layout
Installation Dimensions
Right-handed simplex manifold system Left-handed simplex manifold system
Direction of manifold piping
("L" for left, "R" for right)
Note: Direction of piping (Right or Left) is indicated by facing the manifold
5 2 1 2 X - 3 R - 1
Simplex manifold system
series prefix
Cylinder valve spacing
Type of mounting
Manifold system layout
Number of cylindersGas service
Manifold System Layouts
GASSERVICE
W1(inch)
OXYGEN, AIR, BRESTHING AIR, Ar, He, N2, CO2
ACETYLENE, PROPANE
H1(inch)
W2(inch)
H2(inch)
14
21
61
61
6
6
15
21
5www.genstartech.com
PARTNUMBER
1
2
3
4
5
MANIFOLDSYSTEM LAYOUT
STANDARD LAYOUT
"L" SHAPE LAYOUT
N/A
CROSSOVER LAYOUT
STAGGERED LAYOUT
PARTNUMBER
1
2
3
4
CYLINDERSPACING
5”
10”
13”
18”
PARTNUMBER
1
2
TYPE OFMOUNTING
WALL MOUNT
FLOOR MOUNT
Gas Service
PARTNUMBER
X
Y
F
C
IN
Q
BQ
GASSERVICE
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
SINGLE-SIDE MANIFOLD SYSTEMS
6
Features
Single Manifold Systems5300 series single manifold system consists of a main gas delivery bank and a reserve bank of cylinders.
When the primary cylinder bank is depleted, manually“turn off” the valve on the primary bank and open the
valve on the reserve bank to reactivate gas flow. The changeover of this system needs to be operated manually.
SINGLE MANIFOLD SYSTEMS
��Open-style manifold.
��Silver brazing on piping joints for maximum leak prevention.
��System is designed to accommodate future expanison needs.
��Pressure switch port is available.
��Easy Installation.
��Wall or stand mount are available.
Standard Construction
��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper
pigtails are available as an option. Pigtails for Acetylene models are equipped with dry
flashback arrestor.
��For Acetylene or fuel gas model, regulator outlet is equipped with dry flashback arrestor
(FA30PF) for additional safety. As an option, hydraulic flashback arrestors
are available for an additional charge.
��Gentec's ultra high flow regulator series 155M.
��Relief valve at outlet for protecting downstream piping.
SERIESNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
5300X5300Y5300F5300C5300IN5300Q5300BQ
3000
400
400
3000
3000
3000
3000
10~200
2~15
5~125
5~125
10~200
10~200
10~200
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA510
PIGTAIL, CGA510
PIGTAIL, CGA320
PIGTAIL, CGA580
PIGTAIL, CGA590
PIGTAIL, CGA346
www.genstartech.com
5 3 1 2 X - 5�=5 - 1
SINGLE MANIFOLD SYSTEMS
Installation Dimensions
Ordering Information
Single manifold system
series prefix
"U" shape Layout
Crossover Layout
Staggered Layout
Standard Layout
Please follow the instructions below to select the correct
model number.
Number of cylinders (right side)
Note: Direction of piping (Right or Left) is indicated by facing the manifold
Cylinder valve spacing
Type of mounting
Manifold system layout
Number of cylinders (left side)Gas service
Manifold System Layouts
"L" shape Layout
Example: 5312X-5x5-1 indicates a 5 x 5 cylinder single manifold system. Distance between two cylinders is
10" on standard horizontal layout.
GASSERVICE
W(inch)
OXYGEN, AIR, BREATHING AIR, Ar, He, N2, CO2
ACETYLENE, PROPANE
H1(inch)
H2(inch)
11
11
19
26
61
61
7www.genstartech.com
Type of MountingCylinder Spacing(Center to Center)
Manifold System Layout
PARTNUMBER
1
2
3
4
5
MANIFOLDSYSTEM LAYOUT
STANDARD LAYOUT
"L" SHAPE LAYOUT
"U" SHAPE LAYOUT
CROSSOVER LAYOUT
STAGGERED LAYOUT
PARTNUMBER
1
2
3
4
CYLINDERSPACING
5”
10”
13”
18”
PARTNUMBER
1
2
TYPE OFMOUNTING
WALL MOUNT
FLOOR MOUNT
Gas Service
PARTNUMBER
X
Y
F
C
IN
Q
BQ
GASSERVICE
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
Semi-Automatic Manifold Systems
��Open-style manifold.
��Secondary regulator for consistant high flow delivery pressure to the pipeline.
��Silver brazing on piping joints for maximum leak prevention.
��System is designed to accommodate future expanison needs.
��Unique changeover valve provides uninterrupted supply of gas from primary and reserve banks.
��Pressure switch port is available.
��Easy installation.
��Wall or stand mount are available.
SEMI-AUTOMATIC MANIFOLD SYSTEMS
8
5400 series manifold system is designed to provide an uninterrupted gas supply. It consists of a primary bank
and a reserve bank of cylinders. When the primary cylinder bank is depleted, the changeover takes place
automatically to provide continuous supply of gas from the reserve bank. Upon changing the cylinders, the
regulators on both banks need to be re-adjusted in order for the changeover to occur automatically next time.
Features
Standard Construction
��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are
available as an option. Pigtails for Acetylene models are equipped with dry flashback arrestor.
��For Acetylene or fuel gas model, manifold outlet is equipped with dry flashback arrestor
(FA30PF) for additional safety. As an option, hydraulic flashback arrestors are available
for an additional charge.
��Gentec's ultra high flow regulator series 155L (except for acetylene) & 155M.
��Relief valve at outlet for protecting downstream piping.
SERIESNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
5400X5400Y5400F5400C5400IN5400Q5400BQ
3000
400
400
3000
3000
3000
3000
10~200
2~15
5~125
5~125
10~200
10~200
10~200
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA510
PIGTAIL, CGA510
PIGTAIL, CGA320
PIGTAIL, CGA580
PIGTAIL, CGA590
PIGTAIL, CGA346
www.genstartech.com
SEMI-AUTOMATIC MANIFOLD SYSTEMS
Installation Dimensions
5 4 1 2 X - 5�5 - 1
Ordering Information
Semi-automatic manifold
system prefix
Please follow the instructions below to select the correct
model number.
Number of cylinders (right side)
Note: Direction of piping (Right or Left) is indicated by facing the manifold
Cylinder valve spacing
Type of mounting
Manifold system layout
Number of cylinders (left side)Gas service
Manifold System Layouts
Example: 5412X-5x5-1 indicates a 5 x 5 cylinder semi-automatic manifold system. Distance between cylinder
is 10" on standard horizontal layout.
GASSERVICE
W(inch)
OXYGEN, AIR, BREATHING AIR, Ar, He, N2, CO2
ACETYLENE, PROPANE
H1(inch)
H2(inch)
22
22
19
26
61
61
9www.genstartech.com
"U" shape Layout
Crossover Layout
Staggered Layout
Standard Layout
"L" shape Layout
Type of MountingCylinder Spacing(Center to Center)
Manifold System Layout
PARTNUMBER
1
2
3
4
5
MANIFOLDSYSTEM LAYOUT
STANDARD LAYOUT
"L" SHAPE LAYOUT
"U" SHAPE LAYOUT
CROSSOVER LAYOUT
STAGGERED LAYOUT
PARTNUMBER
1
2
3
4
CYLINDERSPACING
5”
10”
13”
18”
PARTNUMBER
1
2
TYPE OFMOUNTING
WALL MOUNT
FLOOR MOUNT
Gas Service
PARTNUMBER
X
Y
F
C
IN
Q
BQ
GASSERVICE
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
AIR
BREATHING AIR
Automatic Manifold Systems
AUTOMATIC MANIFOLD SYSTEMS
5500 series automatic manifold system is designed to provide an uninteruppted gas supply without any
manual adjustments. This system automatically changes over when the primary cylinder bank is depleted.
Even in case of power failure, the system continues to supply gas without interruption.
10
Features
Standard Construction
Automatic Changeover System��Fully enclosed, tamper- resistant
metal cabinet.
��Pressure switch control.
�� Light indicators provide system
status.
��Systems for fuel gas come with an
Anti-explosive device.
��Remote alarm panels are available as
an option.
��Pressure switch port is available.
Pipeline��Open-style manifold.
��Silver brazing on piping joints for maximum leak
prevention.
��System is designed to accommodate future expanison
needs.
��Unique changeover valve provides uninterrupted supply of
gas from primary and reserve banks.
��Easy Installation.
��Wall or floor mount are available.
SERIESNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
Air
BREATHING AIR
5500X5500EY5500EF5500C5500IN5500Q5500BQ
3000
400
400
3000
3000
3000
3000
10~200
2~15
5~125
5~125
10~200
10~200
10~200
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA510
PIGTAIL, CGA510
PIGTAIL, CGA320
PIGTAIL, CGA580
PIGTAIL, CGA590
PIGTAIL, CGA346
www.genstartech.com
��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are available
as an option. Acetylene models equipped with dry flashback arrestor.
��For Acetylene or fuel gas model, manifold outlet is equipped with dry flashback arrestor (FA30PF). As an
option, hydraulic flashback arrestors are available for an additional charge.
��Gentec's ultra high flow regulator series 153 & 155L.
��Relief valve at outlet for protecting down-stream piping.
AUTOMATIC MANIFOLD SYSTEMS
11
Installation Dimensions
5 5 1 2 E X - 5 �=5 - 1
Ordering Information
Automatic manifold
system series prefix
Please follow the instructions below to select the correct
model number.
Number of cylinders (right side)
Note: Direction of piping (Right or Left) is indicated by facing the manifold
Cylinder valve spacing
Type of mountingManifold system layout
Number of cylinders (left side)Gas service
Manifold System Layouts
Example: 5512EX-5x5-1 indicates a 5 x 5 cylinder automatic manifold system. Distance between cylinder is
10" on standard horizontal layout.
GASSERVICE
W(inch)
OXYGEN, AIR, BREATHING AIR, Ar, He, N2, H2
ACETYLENE, PROPANE
H1(inch)
H2(inch)
22
22
19
26
61
61
www.genstartech.com
Anti-explosion service for fuel gas
"U" shape Layout
Crossover Layout
Staggered Layout
Standard Layout
"L" shape Layout
Type of MountingCylinder Spacing(Center to Center)
Manifold System Layout
PARTNUMBER
1
2
3
4
5
MANIFOLDSYSTEM LAYOUT
STANDARD LAYOUT
"L" SHAPE LAYOUT
"U" SHAPE LAYOUT
CROSSOVER LAYOUT
STAGGERED LAYOUT
PARTNUMBER
1
2
3
4
CYLINDERSPACING
5”
10”
13”
18”
PARTNUMBER
1
2
TYPE OFMOUNTING
WALL MOUNT
FLOOR MOUNT
Gas Service
PARTNUMBER
X
Y
F
C
IN
Q
BQ
GASSERVICE
OXYGEN
ACETYLENE
PROPANE
CO2
Ar, He, N2
Air
BREATHING AIR
Digital Automatic Manifold Systems
12
DIGITAL AUTOMATIC MANIFOLD SYSTEMS
5500D series digital automatic manifold system is designed to provide an uninteruppted gas supply with an
integrated circuit board. The fully automatic manifold system monitors cylinder bank pressure electronically,
controls the changover when the primary cylinder bank is depleted, and eliminates the need to manually
reset the valve. Even in case of power failure, the system continues to supply gas without interruption.
Features
Standard Construction
Automatic Changeover System��Fully enclosed, tamper- resistant
metal cabinet.
��Pressure switch control.
��LED indicators provide system status.
��Pressure switch port is available.
Pipeline��Open-styled manifold.
��Silver brazing on piping joints for maximum leak
prevention.
��System is designed to accomodate future expansion
needs.
��Unique changeover valve provides uninterrupted supply
of gas from primary and reserve banks.
��Easy Installation.
��Wall or floor mount are available.
��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are available
as an option.
��Gentec's ultra high flow regulator series 153 & 155L.
��Relief valve at outlet for protecting downstream piping.
SERIESNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
CO2
Ar, He, N2
N2O
Air
BREATHING AIR
5500DX5500DC5500DIN5500DN5500DQ5500DBQ
3000
3000
3000
3000
3000
3000
10~200
5~125
10~200
10~200
10~200
10~200
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA320
PIGTAIL, CGA580
PIGTAIL, CGA590
PIGTAIL, CGA590
PIGTAIL, CGA346
www.genstartech.com
13
DIGITAL AUTOMATIC MANIFOLD SYSTEMS
www.genstartech.com
Installation Dimension
5 5 1 2 D X - 5�5 - 1
Ordering Information
Digital automatic manifold
system series prefix
Please follow the instructions below to select the correct
model number.
Number of cylinders (right side)
Note: Direction of piping (Right or Left) is indicated by facing the manifold
Cylinder valve spacing
Type of mountingManifold system layout
Number of cylinders (left side)Gas service
Manifold System Layouts
Example: 5512DX-5x5-1 indicates a 5 x 5 oxygen cylinder, digital automatic manifold system. Distance
between two cylinders is 10" on standard horizontal layout.
GASSERVICE
W(inch)
OXYGEN, AIR, BREATHING AIR, Ar, He, N2, CO2, N2O
H1(inch)
H2(inch)
22 19 61
Digital
"U" shape Layout
Crossover Layout
Staggered Layout
Standard Layout
"L" shape Layout
Type of MountingCylinder Spacing(Center to Center)
Manifold System Layout
PARTNUMBER
1
2
3
4
5
MANIFOLDSYSTEM LAYOUT
STANDARD LAYOUT
"L" SHAPE LAYOUT
"U" SHAPE LAYOUT
CROSSOVER LAYOUT
STAGGERED LAYOUT
PARTNUMBER
1
2
3
4
CYLINDERSPACING
5”
10”
13”
18”
PARTNUMBER
1
2
TYPE OFMOUNTING
WALL MOUNT
FLOOR MOUNT
Gas Service
PARTNUMBER
X
C
IN
N
Q
BQ
GASSERVICE
OXYGEN
CO2
Ar, He, N2
N2O
AIR
BREATHING AIR
SEMI-AUTOMATIC MANIFOLD SYSTEMS FOR LIQUID VESSEL
5600 series manifold system is designed specifically for liquid vessels to provide an uninterrupted gas
supply. When the primary liquid vessel is depleted, the changeover takes place automatically to provide
continuous supply of gas from the reserve bank. Upon changing the cylinders, the regulators on both
banks need to be re-adjusted in order for the changover to occur automatically next time.
Semi-Automatic Manifold Systems For Liquid Vessel
14
Features
��Semi-automatic changeover control.
��Unique changeover valve provide uninterrupted supply of gas from primary and reserve banks.
��Easy Installation.
��Check valve on liquid vessel side to prevent high pressure reverse flow to liquid regulator.
��Relief valve at outlet for protecting downstream piping.
��GENTEC high flow regulator series 153M & 853MLC.
Note: The flow rate depends on the vaporization rate of gas supplied.
MODELNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
CO2
Ar, He, N2
5600X5600C5600IN
500
500
500
5~125
5~125
5~125
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA320
PIGTAIL, CGA580
www.genstartech.com
125PSIG is typical, 300PSIG models are available upon request.
15www.genstartech.com
5 6 1 2 X - 5�1 - 1
Semi-automatic manifold
system series prefix
Please follow the instructions below to select the correct
model number.
One liquid vessel (right side)Cylinder spacing
Type of mountingCylinder side
(Left Bank)layout
Number of cylinders (left side)Gas service
Manifold System Layouts
Example: 5612X-5x1-1 indicates a 5 x 1 oxygen cylinder, semi-automatic liquid vessel manifold system.
Distance between two cylinders is 10" on standard horizontal layout of left bank.
GASSERVICE
W(inch)
OXYGEN, Ar, He, N2, CO2
H1(inch)
H2(inch)
22 19 61
Standard Layout
"L" shape Layout
Type of MountingCylinder Spacing(Center to Center)
Manifold System Layout
PARTNUMBER
1
2
4
5
MANIFOLDSYSTEM LAYOUT
STANDARD LAYOUT
"L" SHAPE LAYOUT
CROSSOVER LAYOUT
STAGGERED LAYOUT
PARTNUMBER
1
2
3
4
CYLINDERSPACING
5”
10”
13”
18”
PARTNUMBER
1
2
TYPE OFMOUNTING
WALL MOUNT
FLOOR MOUNT
Gas Service
PARTNUMBER
X
C
IN
GASSERVICE
OXYGEN
CO2
Ar, He, N2
SEMI-AUTOMATIC MANIFOLD SYSTEMS FOR LIQUID VESSEL
Crossover Layout
Staggered Layout
Installation Dimension
Ordering Information
www.genstartech.com16
SEMI-AUTOMATIC MANIFOLD SYSTEMS FOR DUAL LIQUID VESSELS
5700 series manifold system is designed specifically for liquid vessels to provide an uninterrupted gas
supply. When the primary liquid vessel is depleted, the changeover takes place automatically to provide
continuous supply of gas from the reserve liquid vessel. Upon changing the vessel, the regulators on
both banks need to be re-adjusted in order for the changover to occur automatically next time.
Semi-Automatic Manifold Systems For Dual Liquid Vessel
��Semi-automatic changeover control.
��Unique changeover valve provide uninterrupted supply of gas from primary and reserve vessels .
��Check valve at outlets of regulators to prevent high pressure, reverse flow to liquid regulator.
��Easy Installation.
��Relief valve at the outlet for protecting downstream piping.
��GENTEC high flow regulator series 853MLC.
Note: The flow rate depends on the vaporization rate of gas supplied.
MODELNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
OUTLETCONNECTION
INLETDESCRIPTION
OXYGEN
CO2
Ar, He, N2
5700X5700C5700IN
500
500
500
5~125
5~125
5~125
3/4” NPT (M)
3/4” NPT (M)
3/4” NPT (M)
PIGTAIL, CGA540
PIGTAIL, CGA320
PIGTAIL, CGA580
Example: 5700X indicates oxygen dual liquid vessels manifold system.
Features
Ordering Information
125PSIG is typical, 300PSIG models are available upon request.
www.genstartech.com 17
SINGLE-SIDE & DUAL MANIFOLDSWITHOUT CYLINDER HEADER
Designed for single-side cylinder manifold systems (right or left).
Inlet connection thread: 1-11 1/2NPS RH(M).
Outlet connection thread: 3/4” NPT(M).
Max.Inlet Pressure: 3000 psig for Oxygen, CO2, Ar, He, N2, Air
400 psig for Acetylene, Propane
Designed for dual changeover manifold systems. Inlet connection thread: 1-11 1/2NPS RH(M). Outlet connection
thread: 3/4 NPT(M)
Max.Inlet Pressure: 3000 psig for Oxygen, CO2, Ar, He, N2, Air.
400 psig for Acetylene, Propane.
Dual Manifolds Without Cylinder Header
5300X-00
5200X-00R
5200X-00L
Single-Side Manifolds Without Cylinder Header
MODELNUMBER
GASSERVICE
DESCRIPTION
OXYGEN
OXYGEN
ACETYLENE
ACETYLENE
ACETYLENE
ACETYLENE
PROPANE
PROPANE
PROPANE
PROPANE
CO2
CO2
Ar, He, N2
Ar, He, N2
AIR, BREATHING AIR
AIR, BREATHING AIR
MODELNUMBER
GASSERVICE
DESCRIPTION
OXYGEN
ACETYLENE
ACETYLENE
PROPANE
PROPANE
CO2
Ar, He, N2
AIR, BREATHING AIR
5200X-00L5200X-00R5200YD-00L5200YH-00L5200YD-00R5200YH-00R5200FD-00L5200FH-00L5200FD-00R5200FH-00R5200C-00L5200C-00R5200IN-00L5200IN-00R5200Q-00L5200Q-00R
5300X-005300YD-005300YH-005300FD-005300FH-005300C-005300IN-005300Q-00
LEFT BANK with RV
RIGHT BANK with RV
LEFT BANK WITH FA (FA30PF) & RV
LEFT BANK WITH FA (GFA-1000A) & RV
RIGHT BANK WITH FA (FA30PF) & RV
RIGHT BANK WITH FA (GFA-1000A) & RV
LEFT BANK WITH FA (FA30PF) & RV
LEFT BANK WITH FA (GFA-1000LPG) & RV
RIGHT BANK WITH FA (FA30PF) & RV
RIGHT BANK WITH FA (GFA-1000LPG) & RV
LEFT BANK with RV
RIGHT BANK with RV
LEFT BANK with RV
RIGHT BANK with RV
LEFT BANK with RV
RIGHT BANK with RV
WITH FA (FA30PF) with RV
WITH FA (GFA-1000A) with RV
WITH FA (FA30PF) with RV
WITH FA (GFA-1000LPG) with RV
with RV
with RV
with RV
FA: Flashback Arrestor
RV: Relief Valve
FA: Flashback Arrestor
RV: Relief Valve
MODELNUMBER
GASSERVICE
DESCRIPTION
OXYGEN
ACETYLENE
ACETYLENE
PROPANE
PROPANE
CO2
Ar, He, N2
AIR, BREATHING AIR
H2
Designed for semi-automatic changeover manifold systems. Outlet connection thread: 3/4” NPT(M). Inlet connection
thread: 1-11 1/2NPS RH(M); Max.Inlet Pressure: 3000 psig for Oxygen, CO2, Ar, He, N2, Air; 400 psig for Acetylene,
Propane.
Semi-Automatic Manifolds Without Cylinder Hesder
5400X-00
5400X-00
5400YD-00
5400YH-00
5400FD-00
5400FH-00
5400C-00
5400IN-00
5400Q-00
5400H-00
WITH FA (FA30PF) & RV
WITH FA (GFA-1000A) & RV
WITH FA (FA30PF) & RV
WITH FA (GFA-1000LPG) & RV
WITH RV
WITH RV
WITH RV
WITH RV
SEMI-AUTOMATIC MANIFOLDS WITHOUT CYLINDER-HEADER & MANIFOLD CYLINDER-HEADER
Manifold Cylinder Header
��Machined with class "A" brass stock.
��Silver brazing on piping joints for maximum leak
prevention.
��Maximum working pressure: 3000 psig
��Inlet (Header valve): Fuel Gas - CGA510
Oxygen - CGA540
CO2 - CGA320
Ar,He,N2 - CGA580
Air - CGA590
Breathing Air - CGA346
��Outlet: 1-11 1/2NPS
��GHER, GHEL and GHEC series are designed with inlet
connection for each cylinder.
GHER-310X (right-sided manifold pipings)
GHEL-310X (left-sided manifold pipings)
GHEC-310X (dual-sided manifold pipings)
Header extension consists of a gas delivery pipe and header valves. It is expandable for different application
requirements.
Features
FA: Flashback Arrestor
RV: Relief Valve
www.genstartech.com18
www.genstartech.com 19
STATION DROPS
GSOL-2X-R
MODELNUMBER
GASSERVICE
OUTLETCONNECTION
GSOL-1X-R
GSOL-2X-R
GSOL-4X-R
GSOL-1X-H
GSOL-2X-H
GSOL-4X-H
GSOL-1IN-R
GSOL-2IN-R
GSOL-4IN-R
GSOL-1IN-H
GSOL-2IN-H
GSOL-4IN-H
GSOL-1F-R
GSOL-2F-R
GSOL-4F-R
GSOL-1F-H
GSOL-2F-H
GSOL-4F-H
Station Valve, 7/8"-14RH(M), CGA024
Station Valve, 7/8"-14RH(M), CGA024
Station Valve, 7/8"-14RH(M), CGA024
Ball Seat Valve, 9/16"-18RH(M),CGA022
Ball Seat Valve, 9/16"-18RH(M),CGA022
Ball Seat Valve,9/16"-18RH(M), CGA022
Station Valve, 7/8"-14RH(F), CGA034
Station Valve, 7/8"-14RH(F), CGA034
Station Valve, 7/8"-14RH(F), CGA034
Ball Seat Valve, 5/8"-18RH(F), CGA032
Ball Seat Valve, 5/8"-18RH(F), CGA032
Ball Seat Valve, 5/8"-18RH(F), CGA032
Station Valve, 7/8"-14LH(M), CGA025
Station Valve, 7/8"-14LH(M), CGA025
Station Valve, 7/8"-14LH(M), CGA025
Ball Seat Valve, 9/16"-18LH(M), CGA023
Ball Seat Valve, 9/16"-18LH(M), CGA023
Ball Seat Valve, 9/16"-18LH(M), CGA023
NO.OFOUTLET
1
2
4
1
2
4
1
2
4
1
2
4
1
2
4
1
2
4
==�� !"#$Station Drops
OXYGEN
OXYGEN
OXYGEN
OXYGEN
OXYGEN
OXYGEN
CO2,INLET GAS
CO2,INLET GAS
CO2,INLET GAS
CO2,INLET GAS
CO2,INLET GAS
CO2,INLET GAS
FUEL GAS
FUEL GAS
FUEL GAS
FUEL GAS
FUEL GAS
FUEL GAS
Example: GHER-210X indicates a right side oxygen manifold piping system with 2 joints, and 10" joint distance.
GHEX - X X X X
Series number
Number of joints(2/3/5)
Valve Spacing(05”/10”/13”/18”)
Gas service (X/C/IN/Q/F)
SERIESNUMBER
NUMBER OFJOINTS
JOINTDISTANCE
GAS SERVICE
2,3,5
2,3,5
2,3,5
5”10”13”18”5”
10”13”18”5”
10”13”
X: O2
C: CO2
IN: Ar, He, N2
Q: Air,
F: Acetylene
Propane
BQ: Breathing Air
GHER
GHEL
GHEC
PIPING SHAPE &LAYOUT JOINTS
Right-Side
Left-Side
Dual-Side
Ordering Infomation for Manifold Cylinder Header
singlewith ball seat valve
doublewith station valves
quadwith station valves
��GSOL series station drops are
�Inlet connection:1/2”NPT
�Station Regulators are available (page 24)
�In-Line shut-off valves (Ball Valves) are
available (page 18)
�Check valves for oxygen and fuel gases
are available (page 18)
�Labeled for Gas Service
GSOL-1 Series
GSOL-2 Series GSOL-4 Series
20 www.genstartech.com
Header Extensions
HEADER EXTENSIONS, VALVES& ACCESSORIES
GET-9X
GCC-4
GEE-11
MODELNUMBER
LENGTH INLETCONNECTION
DESCRIPTION
4-1/2”
8-1/3”
11-1/3”
8-2/3”
4”
4”
OUTLETCONNECTION
1-11 1/2 NPS-RH (M)
1-11 1/2 NPS-RH (M)
1-11 1/2 NPS-RH (M)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-RH (F)
1-11 1/2 NPS-LH (F)
GEE-4
GEE-8
GEE-11
GET-9X
GCC-4
GCC-4L Extension
Valves & Accossories
GMV-180
Master Valve
GMV-90X
Header Valve
GHFN-X Nut EN-100A Plug
GCC-A
Adaptor
GMQ-183
In-line Ball Valve
MODELNUMBER
GASSERVICE
INLET / OUTLETCONNECTION
DESCRIPTION
GMV-180
GMV-92F
GMV-92IN
GMQ-183
GMQ-184
27-CV-IL
GMV-90XGMV-90F
GMV-90C
GMV-90IN
GMV-90Q
GMV-90BQGMV-92X
*All gases = non-corrosive gases
1-11 1/2 NPS
1/2” NPT / 7/8-14 LH (M) (CGA025)
1/2” NPT / 7/8-14 RH (F) (CGA034)
1/2” NPT / 1/2” NPT
1/2” NPT / 3/4” NPT
1/2” NPT(M) / 1/2” NPT(F)
CGA540 / 1/2”NPTCGA510 / 1/2”NPT
CGA320 / 1/2”NPT
CGA580 / 1/2”NPT
CGA590 / 1/2”NPT
CGA346 / 1/2”NPT1/2” NPT / 7/8-14 RH (M) (CGA024)
*ALL GASES
O2
ACETYLENE, PROPANE
CO2
N2, Ar, He
Air
Breathing Air
O2
ACETYLENE, PROPANE
CO2, Air, N2O, Ar, He
*ALL GASES
*ALL GASES
ACETYLENE, PROPANE, O2
O2
ACETYLENE, PROPANE
CO2, Inert Gas
24-0205 1/4"NPT / 9/16-18RH (CGA022)24-0206 1/4"NPT / 9/16-18LH (CGA023)24-0215AR 1/4"NPT / 5/8-18RH (CGA032)
GMV-92X
Station Valve
24-0205
Ball Seat Valve
MASTER VALVE
HEADER VALVE
STATION VALVE
IN-LINE BALL VALVE
IN-LINE CHECK VALVE
BALL SEAT VALVES
MODELNUMBER
GASSERVICE
INLET / OUTLETCONNECTION
VENTING PRESSURE(PSI)
27-RV-Y-20
27-RV-F-40
27-RV-F-200
27-RV-IN-600
3/4” NPT
3/4” NPT
3/4” NPT
1/2” NPT
ACETYLENE
FUEL GAS
FUEL GAS
O2, Inert Gas
20
40
200
600
MODELNUMBER
DESCRIPTIONMODELNUMBER
DESCRIPTION
NUT 1-11 1/2 NPS RH (F)
NUT 1-11 1/2 NPS LH (F)
PLUG
Adaptor1/4” NPT(M) / 1-11 1/2 NPS RH (M)
Adaptor 1/4” NPT(M) / 1-11 1/2 NPS LH (M)
Adaptor 1/2” NPT(M) / 1-11 1/2 NPS RH (M)
Adaptor 1/2” NPT(M) / 1-11 1/2 NPS LH (M)
Adaptor 3/4” NPT(M) / 1-11 1/2 NPS RH (M)
Adaptor 3/4” NPT(M) / 1-11 1/2 NPS LH (M)
GHFN-X
GHFN-F
EN-100A
R155-111
R155-111A
R155-110
R155-110A
GCC-A
GCC-C
27-CV-IL
In-line Check Valve
Relief Valves
Elbow
T
21www.genstartech.com
PIGTAILS,WALL MOUNTS,PIPE HOLDERS / SUPPORTS
High Pressure Pigtails
Cylinder Wall Mounts, Pipe Holders, and Pipe Supports
GMB-7
GMB-1 GMB-3
GMB-9
GMB-6A
Note: End connectors of stainless steel tubings and pigtails are made of brass material.
( Stainless steel
braided Teflon
core pigtail )
MODELNUMBER
DESCRIPTION
GMB-1GMB-2GMB-3GMB-4
GMB-6AGMB-7GMB-9
SINGLE CYLINDER WALL MOUNT (9” wide)
SINGLE CYLINDER WALL MOUNT (14” wide)
DUAL CYLINDER WALL MOUNT (9” wide)
DUAL CYLINDER WALL MOUNT (14” wide)
PIPE SUPPORT (61”)
PIPE HOLDER Bracket
PIPE HOLDER
MODELNUMBER
GASSERVICE
INLET/OUTLETCONNECTION
LENGTH TYPE CHECKVALVE
FLASH BACKARRESTOR
��Rigid copper and flexible stainless steel braided
Teflon core pigtails are available.
��Stainless steel braided pigtails come with anti-whip armor.
��Dry Flash Back Arrestor is included in Fuel Gas Models.
��3000 PSI maximum working pressure.
OXYGEN
OXYGEN
OXYGEN
CO2
CO2
CO2
Ar,He,N2
Ar,He,N2
Ar,He,N2
Air
Air
Air
Breathing Air
Breathing Air
Breathing Air
Acetylene
Acetylene
Propane
Propane
Propane
GPF-36X-CV
GPF-24X-CV
GRP-24X-CV
GPS-36C-CV
GPS-24C-CV
GRP-24C-CV
GPS-36IN-CV
GPS-24IN-CV
GRP-24IN-CV
GPS-36Q-CV
GPS-24Q-CV
GRP-24Q-CV
GPS-36Q-CV-346
GPS-24Q-CV-346
GRP-24Q-CV-346
GPS-36Y-FA
GPS-24Y-FA
GPS-36F-FA
GPS-24F-FA
GRP-24F-FA
CGA540
CGA540
CGA540
CGA320
CGA320
CGA320
CGA580
CGA580
CGA580
CGA590
CGA590
CGA590
CGA346
CGA346
CGA346
CGA510
CGA510
CGA510
CGA510
CGA510
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
COPPER PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
COPPER PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
COPPER PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
COPPER PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
COPPER PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL
COPPER PIGTAIL
36"
24"
24"
36"
24"
24"
36"
24"
24"
36"
24"
24"
36"
24"
24"
36"
24"
36"
24"
24"
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
( Copper pigtail)
22 www.genstartech.com
FLASHBACK ARRESTORS
Hydraulic Flash Arrestor is designed for use on Acetylene or Fuel Gas Manifold Systems to protect the main
gas supply from the dangers of reverse flow and flashbacks. A pressure relief valve is included to provide
additional protection from excessive pressure.
Hydraulic Flashback Arrestors
In-line Low Pressure Flashback Arrestors
GFA-300A
Flashback Arrestor
GFS-300
Stand
Designed for use on Acetylene or Fuel Gas Manifold Systems with low pressure piping system to protect the
main gas supply from the dangers of reverse flow and flashbacks by stainless steel sintered elements and
check valves.
MODELNUMBER
GASSERVICE
FA30PFFA30P0
DELIVERYFLOW
(SCFH)
WORKINGPRESSURE
(psi)
INLETCONNECTION
OUTLETCONNECTION
ACETYLENE / PROPANE
OXYGEN15/22
145
2450
5700
3/4” NPT (F)
3/4” NPT (F)
3/4” NPT (F)
3/4” NPT (F)
MODELNUMBER
GASSERVICE
GFA-1000AGFA-1000LPGGFA-300AGFA-300LPGGFS-1000GFS-300
DELIVERY FLOW(SCFH)
1000
1000
300
300
ACETYLENE
PROPANE, LPG
ACETYLENE
PROPANE, LPG
STAND FOR GFA-1000A & GFA-1000LPG
STAND FOR GFA-300A & GFA-300LPG
FA30PO
RELIEF VALVE VENT PRESSURE(PSI)
20
40
20
40
INLET/OUTLETCONNECTION
1 1/2”NPT
1 1/2”NPT
1 1/2”NPT
1 1/2”NPT
23www.genstartech.com
FA40HPF
FLASHBACK ARRESTORS,PRESSURE SWITCHES, ALARMS
Designed for use on Acetylene or Fuel Gas Manifold Systems with high pressure piping system to protect the
main gas supply from the dangers of reverse flow and flashbacks. Stainless steel sintered elements and check
valves are constructed for additional protection.
High Pressure Flashback Arrestors
MODELNUMBER
GASSERVICE
FA40HPF
MAX.INLETPRESSURE
(psi)
INLETCONNECTION
OUTLETCONNECTION
ACETYLENE, PROPANE 400 1/4” NPT (F) 1/4” NPT (M)
Pressure switchs are designed for gas manifold systems to activate remote alarm systems. Operates when
cylinder/line pressure is below minimum pressure setting.
Pressure Switches ( Explosion-Proof Type )
Remote alarm panel is suitable for all manifold systems. The alarm is activated to provide audio and visual
warning when the service bank is empty. A press of reset button in front of the panel will silence the buzzer.
The red alarm light will remain illuminated until the empty bank is replaced.
Remote Alarm Panels
MODELNUMBER
PRESSURERANGE
(psi)
GHPS-1GHPS-2GHPS-3GHPS-4GHPS-5GHPS-6GHPS-7
MAX.INLETPRESSURE
(psi)
PRESSURECONNECTION
5~50
30~600
100~1500
400~1500
15~75
50~450
2~25
500
1500
2200
4500
1000
3000
1000
1/4” NPT
1/4” NPT
1/4” NPT
1/4” Female NPT
1/4” Female NPT
1/4” Female NPT
1/4” Female NPT
MODELNUMBER
SGPA-1SGPA-1-VSGPA-2SGPA-4
TYPE NO,OFGASES
1
1
2
4
AUDIO & VISUAL ALARM
VISUAL ALARM
AUDIO & VISUAL ALARM
AUDIO & VISUAL ALARM
EXPLOSION-PROOFTYPE
NO
NO
NO
YES
YES
YES
YES
Explosion-Proof Type
24 www.genstartech.com
191FM-60
Flowmeters
Regulator Flashback Arrestors
Designed for mounting on the regulator outlet. Internal stainless steel sintered elements and check valves
are constructed to provide protection from flashbacks.
FA7RF
FA7RO
RH14X
RH19X
Designed with a check valve to provide protection from reverse flow during gas cutting processes.
Quick Connectors with Check Valves
MODELNUMBER
GASSERVICE
RH14XRH14FRH18XRH18F
WORKINGPRESSURE
(psi)
INLETCONNECTION
OUTLETCONNECTION
OXYGEN
FUEL GAS
OXYGEN
FUEL GAS
145
30
145
30
9/16-18 RH (F)
9/16-18 LH (F)
9/16-18 RH (F)
9/16-18 LH (F)
9/16-18 RH (M)
9/16-18 LH (M)
1/4” HOSE NIPPLE
1/4” HOSE NIPPLE
Precision gas flow control for MIG and TIG welding, laboratorial, and other industrial applications. Suitable
for use on piping systems.
MODELNUMBER
GASSERVICE
FA7RFFA7RO
WORKINGPRESSURE
(psi)
INLETCONNECTION
OUTLETCONNECTION
ACETYLENE / PROPANE
OXYGEN
15/22
145
9/16-18 LH (F)
9/16-18 RH (F)
9/16-18 LH(M)
9/16-18 RH (M)
MODELNUMBER
GASSERVICE
191FM-60
191FM-60A
191FM-100
191FM-100A
191FM-70
191FM-70A
191FM-50
191FM-50A
191FM-150
191FM-150A
WORKINGPRESSURE
(psi)
INLETCONNECTION
OUTLETCONNECTION
Ar / CO2
Ar / CO2
Ar / CO2
Ar / CO2
Nitrogen / Air
Nitrogen / Air
Helium
Helium
Helium
Helium
50
50
50
50
50
50
50
50
50
50
1/4"NPT (M)
9/16"-18 RH (F)
1/4"NPT (M)
9/16"-18 RH (F)
1/4"NPT (M)
9/16"-18 RH (F)
1/4"NPT (M)
9/16"-18 RH (F)
1/4"NPT (M)
9/16"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
5/8"-18 RH (F)
REGULATORS FLASHBACK ARRESTORS,QUICK CONNECTORS & FLOW METERS
FLOWRATE
10-60SCFH
10-60SCFH
20-100SCFH
20-100SCFH
10-70SCFH
10-70SCFH
10-50SCFH
10-50SCFH
20-150SCFH
20-150SCFH
www.genstartech.com
155MY-15
591MX-750
153MC-125
155MX-125155MX-200155MY-15155MF-40155MIN-125155MIN-200155MQ-125155MQ-200155MC-125155MC-200
153MX-125153MX-200153MY-15153MF-40153MF-125153MIN-125153MIN-200153MQ-125153MQ-200153MC-125153MC-200
591MX-750591MX-1500591MX-3000591MIN-1500591MIN-3000591MQ-1500591MQ-3000
853MLCX-125853MLCCD-125853MLCIN-125
OXYGEN
ACETYLENE
LPG
Ar, He, N2
AIR
CO2
OXYGEN
ACETYLENE
LPG
Ar, He, N2
AIR
CO2
OXYGEN
Ar, He, N2
AIIR
OXYGEN
CO2
Ar, N2
5~125
10~200
2~15
2~40
5~125
10~200
5~125
10~200
5~125
10~200
5~125
10~200
2~15
2~40
5~125
5~125
10~200
5~125
10~200
5~125
10~200
50~750
100~1500
200~3000
100~1500
200~3000
100~1500
200~3000
5~125
5~125
5~125
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS LH (M)
1-11 1/2 NPS LH (M)
1-11 1/2 NPS LH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (M)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS LH (F)
1-11 1/2 NPS LH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS LH (F)
1-11 1/2 NPS LH (F)
1-11 1/2 NPS LH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
1-11 1/2 NPS RH (F)
853LC
SERIES
155M
SERIES
153M
SERIES
591-A
SERIES
MODELNUMBER
GASSERVICE
INLETCONNECTION
OUTLETCONNECTION
SERIES MAX.INLETPRESSURE
(psi)
DELIVERYPRESSURE
(psi)
3000
3000
400
400
3000
3000
3000
3000
3000
3000
3000
3000
400
400
400
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
3000
500
500
500
853MLCX-125
155M Series 153M Series 591M Series 853MLC Series
25www.genstartech.com
MANIFOLD REGULATORS
26 www.genstartech.com
STATION & LINE REGULATORS
3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)
1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)
1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)
7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 LH (F)7/8-14 LH (F)7/8-14 LH (F)
7/8-14 RH (M)7/8-14 RH (M)7/8-14 RH (M)7/8-14 RH (M)
7/8-14 LH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 LH (F)
7/8-14 LH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 LH (F)
1-11 1/2 NPS LH (F)1-11 1/2 NPS RH (F)1-11 1/2 NPS LH (F)
3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)
1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)
1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)
9/16-18 RH (M)9/16-18 RH (M)9/16-18 RH (M)9/16-18 LH (M)9/16-18 LH (M)9/16-18 LH (M)5/8-18 RH (F)5/8-18 RH (F)5/8-18 RH (F)5/8-18 RH (F)
9/16-18 LH (M)9/16-18 RH (M)9/16-18 RH (M)9/16-18 RH (M)9/16-18 LH (M)
9/16-18 LH (M)5/8-18 RH (F)5/8-18 RH (F)
9/16-18 RH (M)9/16-18 RH (M)9/16-18 LH (M)
7/8-14 LH (M)7/8-14 RH (M)7/8-14 LH (M)
155LX-80155LX-125155LX-200155LY-15155LF-125155LIN-80155LIN-125155LIN-200155LQ-80155LQ-125155LQ-200155LC-125
152LX-125152LY-15152LF-80152LIN-125152LQ-125152LC-125
853LX-125853LY-15853LF-80853LF-125853LIN-125853LQ-125853LC-125
152SX-40152SX-80152SX-125152SY-15152SF-80152SF-125152SIN-40152SIN-80152SIN-125152SIN-40FG
853SF-80853SX-40853SX-80853SX-125853SY-15
853SRF-80853SRIN-80853SRIN-125853SRX-80853SRX-125853SRY-15
155SF-80155SX-125155SY-15
350350350350350350350350350350350350
350350350350350350
350350350350350350350
200200200200200200200200200200
200200200200200
200200200200200200
350350350
155LX-80
152SX-80
853SRIN-40
155L
SERIES
152L
SERIES
853L
SERIES
152S
SERIES
853S
SERIES
MODELNUMBER
GASSERVICE
MAX.INLETPRESSURE
(psi)
INLETCONNECTION
OUTLETCONNECTION
SERIES DELIVERYPRESSURE
(psi)
3~805~120
10~2002~15
5~1203~80
5~12010~200
3~805~120
10~2005~120
5~1202~153~80
5~1205~1205~120
5~1202~153~80
5~1205~1205~1205~120
2~404~80
5~1252~154~80
5~1252~404~80
5~1250~40 SCFH
4~802~404~80
5~1252~15
4~804~80
5~1254~80
5~1252~15
4~805~1252~15
155S
SERIES
853SR
SERIES
OXYGEN
ACETYLENELPG
Ar, He, N2
AIR
CO2
OXYGENACETYLENE
LPGAr, He, N2
AIRCO2
OXYGENACETYLENE
LPGAr, He, N2
AIRCO2
OXYGEN
ACETYLENE
LPG
AIRINERT GAS
CO2
LPG
OXYGEN
ACETYLENE
LPGINERT GAS
CO2
OXYGENACETYLENE
LPGOXYGEN, INERT GAS, CO2
ACETYLENE
155L Series 152S Series 853S Series
27www.genstartech.com
WARRANTY INFORMATION
Any GENTEC® apparatus found to be defective either in material or workmanship during the time set
forth below will be replaced by Genstar Technologies Company, Incorporated or its Authorized
Distributors, provided that said apparatus was used under normal conditions for the purpose intended.
Limited Warranty Period: The warranty period is as shown below, from the date of original purchase.
Product Type Warranty from the Date of Original PurchaseGas Manifold Systems 2 years
Pigtails 90 days
GENTEC® apparatus damaged or rendered inoperative due to abuse, negligence, misuse, accident
or abnormal wear and tear is not covered by this warranty and must be repaired at the sole expense
of the equipment owner. GENTEC® apparatus should be serviced or repaired by Genstar Technolo-
gies Company, Incorporated or designated service facilities only. Service or repair of this apparatus
by other than Genstar Technologies Company, Incorporated or designated service facilities may
void any warranties and relieve Genstar Technologies Company, Incorporated of any claims for
damage and/or liability.
To make a claim under this warranty, Buyer must notify Genstar Technologies Company, Incorpo-
rated or its Authorized Distributor of the details of such claim within 30 days of discovering a defect in
material or workmanship along with proof of purchase. The Buyer will be responsible for transporta-
tion costs and related risks.
Genstar Technologies Company, Incorporated shall not, under any circumstances, be liable forany damages including but not limited to: indirect, incidental, consequential, or special damages,whether such damages result from negligence, breach of warranty or otherwise.
There are no other warranties, expressed or implied, except as stated herein. This warranty gives you
specific legal rights, and you may also have other rights which vary from state to state. Genstar
Technologies Company, Incorporated reserves the right to discontinue manufacturing of any prod-
uct or change product materials, design or specifications without notice.