TABLE OF CONTENTS

Dual Manifold Systems

Single-Side Manifold Systems

Single Manifold Systems

Semi-Automatic Manifold Systems

Automatic Manifold Systems

Digital Automatic Manifold Systems

Semi-Automatic Manifold Systems for Liquid Vessel

Semi-Automatic Manifold Syetems for Dual Liquid Vessels

Single-Side & Dual Manifolds without Cylinder Header

Semi-Automatic Manifolds without Cylinder Header & Manifold Cylinder Header

Station Drops

Header Extensions, Valves & Accessories

Pigtails, Wall mounts, Pipe Holders / Supports

Flashback Arrestors

Flashback Arrestors, Pressure Switches & Alarms

Flashback Arrestors, Quick Connectors & Flowmeters

Manifold Regulators

Station & Line Regulators

Manifold Purchase Specifications Form 2

1

Manifold Systems3

4-5

6-7

8-9

10-11

12-13

14-15

16

17

18

19

20

21

22

23

24

25

26

27

www.genstartech.com

TABLE OF CONTENTS

Manifold Accessories

Warranty Information

1 Application of the manifold system: =� Industrial � Specialty Gas � Others

2 Gas service: � Oxygen ==� Acetylene � Propane ==� Air

� Carbon Dioxide (CO2)===� Inert Gases (Argon, Nitrogen, Helium) ==� Others

3 Type of manifold system required: � Manual==� Semi-Automatic= =� Automatic

4 Outlet pressure required: (PSI)

5 Outlet flow rate required: (SCFH)

6 Type of mounting: =� Wall Mount ==� Floor Mount

7 Cylinder Spacing (Center to Center): =� 5” ==� 10” � 13” ==� 18”

8 Number of cylinders required: Left Bank , Right Bank

9 Manifold system layout:

10 Accessories:

Pressure Switch Model No. Qty

Alarm System Model No. Qty

Gas Terminal (Pipeline) Model No. Qty

Gas Heater* Model No. Qty

Others Model No. Qty

*: Optional 500 SCFH heater is available for CO2 & N2O gas service with withdrawal rates above 35 SCFH / cylinder.

Note: Please fill out the above form so GENTEC can recommend the most suitable manifold system

for your application. Please do not hesitate to contact us for more information.

APPLICATION FORM

2

Manifold Purchase Specifications Form

www.genstartech.com

2 "L" shape Layout

4 Crossover Layout

5 Staggered Layout

1 Standard Layout

5200 Series

3 "U" shape Layout

5300/5400/5500/5500D SeriesSeries No.Layout

Manifolds

Cylinder

5600 Series

Ordering Information

Please specify the "model number" when ordering. For example: 5100X indicates a dual “oxygen” manifold

system.

Dual Manifold Systems

��Silver brazing on piping joints for maximum leak prevention.

��Individual Header Valves.

��Wall mount installation only.

Features

��24" flexible high pressure stainless steel braided pigtails with

check valve, Rigid copper pigtails are available as an option.

Pigtails for acetylene models are equipped with dry flashback

arrestor.

��For Acetylene or Fuel gas model, regulator outlet is equipped

with a dry flashback arrestor (FA30PF) for additional safety.

��Gentec's high flow regulator series 153M.

��Relief valve at outlet for protecting downstream piping.

DUAL MANIFOLD SYSTEMS

3

Standard Construction

www.genstartech.com

MODELNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

5100X5100Y5100F5100C5100IN5100Q5100BQ

3000

400

400

3000

3000

3000

3000

10~200

2~15

5~125

5~125

10~200

10~200

10~200

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA510

PIGTAIL, CGA510

PIGTAIL, CGA320

PIGTAIL, CGA580

PIGTAIL, CGA590

PIGTAIL, CGA346

5100 series dual manifold system is a simple gas delivery system which provides a maximum of 2 cylinders in

service at one time . This non-extendable system is suitable for maintenance and simple gas applications or

one cylinder in service at one time and one in reserve where a manual change over is required.

��Open-style manifold.

��System can be designed for right or left-hand direction cylinder bank.

��Silver brazing on piping joints for maximum leak prevention.

��System is designed to accomodate future expansion needs.

��Pressure switch port is available.

��Wall or stand mount are available.

Single-Side Manifold Systems

��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are available

as an option. Pigtails for Acetylene models are equipped with a dry flashback arrestor.

��For Acetylene or fuel gas model, regulator outlet is equipped with a dry flashback arrestor (FA30PF) for

additional safety. As an option, hydraulic flashback arrestors are available for an additional

charge.

��Gentec's high flow regulator series 155M.

��Relief valve at outlet for protecting downstream piping.

SINGLE-SIDE MANIFOLD SYSTEMS

4

5200 series single-side manifold system is designed for a single source of gas supply from one cylinder bank.

Although this system can be used as a main delivery system, it is typically used in industrial and medical

applications as a high pressure emergency back-up system for liquid vessel or bulk systems.

Features

Standard Construction

SERIESNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

5200X5200Y5200F5200C5200IN5200Q5200BQ

3000

400

400

3000

3000

3000

3000

10~200

2~15

5~125

5~125

10~200

10~200

10~200

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA510

PIGTAIL, CGA510

PIGTAIL, CGA320

PIGTAIL, CGA580

PIGTAIL, CGA590

PIGTAIL, CGA346

www.genstartech.com

"L" shape Layout

Crossover Layout

Staggered Layout

Standard Layout

Type of MountingCylinder Spacing(Center to Center)

Example: 5212X-3R-1 indicates a 3 cylinder right-handed simplex oxygen manifold system. Distance between

each cylinder is 10" on standard horizontal layout.

Ordering Information

Please follow the instructions below to select the correct

model number.

Manifold System Layout

Installation Dimensions

Right-handed simplex manifold system Left-handed simplex manifold system

Direction of manifold piping

("L" for left, "R" for right)

Note: Direction of piping (Right or Left) is indicated by facing the manifold

5 2 1 2 X - 3 R - 1

Simplex manifold system

series prefix

Cylinder valve spacing

Type of mounting

Manifold system layout

Number of cylindersGas service

Manifold System Layouts

GASSERVICE

W1(inch)

OXYGEN, AIR, BRESTHING AIR, Ar, He, N2, CO2

ACETYLENE, PROPANE

H1(inch)

W2(inch)

H2(inch)

14

21

61

61

6

6

15

21

5www.genstartech.com

PARTNUMBER

1

2

3

4

5

MANIFOLDSYSTEM LAYOUT

STANDARD LAYOUT

"L" SHAPE LAYOUT

N/A

CROSSOVER LAYOUT

STAGGERED LAYOUT

PARTNUMBER

1

2

3

4

CYLINDERSPACING

5”

10”

13”

18”

PARTNUMBER

1

2

TYPE OFMOUNTING

WALL MOUNT

FLOOR MOUNT

Gas Service

PARTNUMBER

X

Y

F

C

IN

Q

BQ

GASSERVICE

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

SINGLE-SIDE MANIFOLD SYSTEMS

6

Features

Single Manifold Systems5300 series single manifold system consists of a main gas delivery bank and a reserve bank of cylinders.

When the primary cylinder bank is depleted, manually“turn off” the valve on the primary bank and open the

valve on the reserve bank to reactivate gas flow. The changeover of this system needs to be operated manually.

SINGLE MANIFOLD SYSTEMS

��Open-style manifold.

��Silver brazing on piping joints for maximum leak prevention.

��System is designed to accommodate future expanison needs.

��Pressure switch port is available.

��Easy Installation.

��Wall or stand mount are available.

Standard Construction

��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper

pigtails are available as an option. Pigtails for Acetylene models are equipped with dry

flashback arrestor.

��For Acetylene or fuel gas model, regulator outlet is equipped with dry flashback arrestor

(FA30PF) for additional safety. As an option, hydraulic flashback arrestors

are available for an additional charge.

��Gentec's ultra high flow regulator series 155M.

��Relief valve at outlet for protecting downstream piping.

SERIESNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

5300X5300Y5300F5300C5300IN5300Q5300BQ

3000

400

400

3000

3000

3000

3000

10~200

2~15

5~125

5~125

10~200

10~200

10~200

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA510

PIGTAIL, CGA510

PIGTAIL, CGA320

PIGTAIL, CGA580

PIGTAIL, CGA590

PIGTAIL, CGA346

www.genstartech.com

5 3 1 2 X - 5�=5 - 1

SINGLE MANIFOLD SYSTEMS

Installation Dimensions

Ordering Information

Single manifold system

series prefix

"U" shape Layout

Crossover Layout

Staggered Layout

Standard Layout

Please follow the instructions below to select the correct

model number.

Number of cylinders (right side)

Note: Direction of piping (Right or Left) is indicated by facing the manifold

Cylinder valve spacing

Type of mounting

Manifold system layout

Number of cylinders (left side)Gas service

Manifold System Layouts

"L" shape Layout

Example: 5312X-5x5-1 indicates a 5 x 5 cylinder single manifold system. Distance between two cylinders is

10" on standard horizontal layout.

GASSERVICE

W(inch)

OXYGEN, AIR, BREATHING AIR, Ar, He, N2, CO2

ACETYLENE, PROPANE

H1(inch)

H2(inch)

11

11

19

26

61

61

7www.genstartech.com

Type of MountingCylinder Spacing(Center to Center)

Manifold System Layout

PARTNUMBER

1

2

3

4

5

MANIFOLDSYSTEM LAYOUT

STANDARD LAYOUT

"L" SHAPE LAYOUT

"U" SHAPE LAYOUT

CROSSOVER LAYOUT

STAGGERED LAYOUT

PARTNUMBER

1

2

3

4

CYLINDERSPACING

5”

10”

13”

18”

PARTNUMBER

1

2

TYPE OFMOUNTING

WALL MOUNT

FLOOR MOUNT

Gas Service

PARTNUMBER

X

Y

F

C

IN

Q

BQ

GASSERVICE

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

Semi-Automatic Manifold Systems

��Open-style manifold.

��Secondary regulator for consistant high flow delivery pressure to the pipeline.

��Silver brazing on piping joints for maximum leak prevention.

��System is designed to accommodate future expanison needs.

��Unique changeover valve provides uninterrupted supply of gas from primary and reserve banks.

��Pressure switch port is available.

��Easy installation.

��Wall or stand mount are available.

SEMI-AUTOMATIC MANIFOLD SYSTEMS

8

5400 series manifold system is designed to provide an uninterrupted gas supply. It consists of a primary bank

and a reserve bank of cylinders. When the primary cylinder bank is depleted, the changeover takes place

automatically to provide continuous supply of gas from the reserve bank. Upon changing the cylinders, the

regulators on both banks need to be re-adjusted in order for the changeover to occur automatically next time.

Features

Standard Construction

��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are

available as an option. Pigtails for Acetylene models are equipped with dry flashback arrestor.

��For Acetylene or fuel gas model, manifold outlet is equipped with dry flashback arrestor

(FA30PF) for additional safety. As an option, hydraulic flashback arrestors are available

for an additional charge.

��Gentec's ultra high flow regulator series 155L (except for acetylene) & 155M.

��Relief valve at outlet for protecting downstream piping.

SERIESNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

5400X5400Y5400F5400C5400IN5400Q5400BQ

3000

400

400

3000

3000

3000

3000

10~200

2~15

5~125

5~125

10~200

10~200

10~200

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA510

PIGTAIL, CGA510

PIGTAIL, CGA320

PIGTAIL, CGA580

PIGTAIL, CGA590

PIGTAIL, CGA346

www.genstartech.com

SEMI-AUTOMATIC MANIFOLD SYSTEMS

Installation Dimensions

5 4 1 2 X - 5�5 - 1

Ordering Information

Semi-automatic manifold

system prefix

Please follow the instructions below to select the correct

model number.

Number of cylinders (right side)

Note: Direction of piping (Right or Left) is indicated by facing the manifold

Cylinder valve spacing

Type of mounting

Manifold system layout

Number of cylinders (left side)Gas service

Manifold System Layouts

Example: 5412X-5x5-1 indicates a 5 x 5 cylinder semi-automatic manifold system. Distance between cylinder

is 10" on standard horizontal layout.

GASSERVICE

W(inch)

OXYGEN, AIR, BREATHING AIR, Ar, He, N2, CO2

ACETYLENE, PROPANE

H1(inch)

H2(inch)

22

22

19

26

61

61

9www.genstartech.com

"U" shape Layout

Crossover Layout

Staggered Layout

Standard Layout

"L" shape Layout

Type of MountingCylinder Spacing(Center to Center)

Manifold System Layout

PARTNUMBER

1

2

3

4

5

MANIFOLDSYSTEM LAYOUT

STANDARD LAYOUT

"L" SHAPE LAYOUT

"U" SHAPE LAYOUT

CROSSOVER LAYOUT

STAGGERED LAYOUT

PARTNUMBER

1

2

3

4

CYLINDERSPACING

5”

10”

13”

18”

PARTNUMBER

1

2

TYPE OFMOUNTING

WALL MOUNT

FLOOR MOUNT

Gas Service

PARTNUMBER

X

Y

F

C

IN

Q

BQ

GASSERVICE

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

AIR

BREATHING AIR

Automatic Manifold Systems

AUTOMATIC MANIFOLD SYSTEMS

5500 series automatic manifold system is designed to provide an uninteruppted gas supply without any

manual adjustments. This system automatically changes over when the primary cylinder bank is depleted.

Even in case of power failure, the system continues to supply gas without interruption.

10

Features

Standard Construction

Automatic Changeover System��Fully enclosed, tamper- resistant

metal cabinet.

��Pressure switch control.

�� Light indicators provide system

status.

��Systems for fuel gas come with an

Anti-explosive device.

��Remote alarm panels are available as

an option.

��Pressure switch port is available.

Pipeline��Open-style manifold.

��Silver brazing on piping joints for maximum leak

prevention.

��System is designed to accommodate future expanison

needs.

��Unique changeover valve provides uninterrupted supply of

gas from primary and reserve banks.

��Easy Installation.

��Wall or floor mount are available.

SERIESNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

Air

BREATHING AIR

5500X5500EY5500EF5500C5500IN5500Q5500BQ

3000

400

400

3000

3000

3000

3000

10~200

2~15

5~125

5~125

10~200

10~200

10~200

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA510

PIGTAIL, CGA510

PIGTAIL, CGA320

PIGTAIL, CGA580

PIGTAIL, CGA590

PIGTAIL, CGA346

www.genstartech.com

��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are available

as an option. Acetylene models equipped with dry flashback arrestor.

��For Acetylene or fuel gas model, manifold outlet is equipped with dry flashback arrestor (FA30PF). As an

option, hydraulic flashback arrestors are available for an additional charge.

��Gentec's ultra high flow regulator series 153 & 155L.

��Relief valve at outlet for protecting down-stream piping.

AUTOMATIC MANIFOLD SYSTEMS

11

Installation Dimensions

5 5 1 2 E X - 5 �=5 - 1

Ordering Information

Automatic manifold

system series prefix

Please follow the instructions below to select the correct

model number.

Number of cylinders (right side)

Note: Direction of piping (Right or Left) is indicated by facing the manifold

Cylinder valve spacing

Type of mountingManifold system layout

Number of cylinders (left side)Gas service

Manifold System Layouts

Example: 5512EX-5x5-1 indicates a 5 x 5 cylinder automatic manifold system. Distance between cylinder is

10" on standard horizontal layout.

GASSERVICE

W(inch)

OXYGEN, AIR, BREATHING AIR, Ar, He, N2, H2

ACETYLENE, PROPANE

H1(inch)

H2(inch)

22

22

19

26

61

61

www.genstartech.com

Anti-explosion service for fuel gas

"U" shape Layout

Crossover Layout

Staggered Layout

Standard Layout

"L" shape Layout

Type of MountingCylinder Spacing(Center to Center)

Manifold System Layout

PARTNUMBER

1

2

3

4

5

MANIFOLDSYSTEM LAYOUT

STANDARD LAYOUT

"L" SHAPE LAYOUT

"U" SHAPE LAYOUT

CROSSOVER LAYOUT

STAGGERED LAYOUT

PARTNUMBER

1

2

3

4

CYLINDERSPACING

5”

10”

13”

18”

PARTNUMBER

1

2

TYPE OFMOUNTING

WALL MOUNT

FLOOR MOUNT

Gas Service

PARTNUMBER

X

Y

F

C

IN

Q

BQ

GASSERVICE

OXYGEN

ACETYLENE

PROPANE

CO2

Ar, He, N2

Air

BREATHING AIR

Digital Automatic Manifold Systems

12

DIGITAL AUTOMATIC MANIFOLD SYSTEMS

5500D series digital automatic manifold system is designed to provide an uninteruppted gas supply with an

integrated circuit board. The fully automatic manifold system monitors cylinder bank pressure electronically,

controls the changover when the primary cylinder bank is depleted, and eliminates the need to manually

reset the valve. Even in case of power failure, the system continues to supply gas without interruption.

Features

Standard Construction

Automatic Changeover System��Fully enclosed, tamper- resistant

metal cabinet.

��Pressure switch control.

��LED indicators provide system status.

��Pressure switch port is available.

Pipeline��Open-styled manifold.

��Silver brazing on piping joints for maximum leak

prevention.

��System is designed to accomodate future expansion

needs.

��Unique changeover valve provides uninterrupted supply

of gas from primary and reserve banks.

��Easy Installation.

��Wall or floor mount are available.

��24" flexible high pressure stainless steel braided pigtails with check valve. Rigid copper pigtails are available

as an option.

��Gentec's ultra high flow regulator series 153 & 155L.

��Relief valve at outlet for protecting downstream piping.

SERIESNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

CO2

Ar, He, N2

N2O

Air

BREATHING AIR

5500DX5500DC5500DIN5500DN5500DQ5500DBQ

3000

3000

3000

3000

3000

3000

10~200

5~125

10~200

10~200

10~200

10~200

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA320

PIGTAIL, CGA580

PIGTAIL, CGA590

PIGTAIL, CGA590

PIGTAIL, CGA346

www.genstartech.com

13

DIGITAL AUTOMATIC MANIFOLD SYSTEMS

www.genstartech.com

Installation Dimension

5 5 1 2 D X - 5�5 - 1

Ordering Information

Digital automatic manifold

system series prefix

Please follow the instructions below to select the correct

model number.

Number of cylinders (right side)

Note: Direction of piping (Right or Left) is indicated by facing the manifold

Cylinder valve spacing

Type of mountingManifold system layout

Number of cylinders (left side)Gas service

Manifold System Layouts

Example: 5512DX-5x5-1 indicates a 5 x 5 oxygen cylinder, digital automatic manifold system. Distance

between two cylinders is 10" on standard horizontal layout.

GASSERVICE

W(inch)

OXYGEN, AIR, BREATHING AIR, Ar, He, N2, CO2, N2O

H1(inch)

H2(inch)

22 19 61

Digital

"U" shape Layout

Crossover Layout

Staggered Layout

Standard Layout

"L" shape Layout

Type of MountingCylinder Spacing(Center to Center)

Manifold System Layout

PARTNUMBER

1

2

3

4

5

MANIFOLDSYSTEM LAYOUT

STANDARD LAYOUT

"L" SHAPE LAYOUT

"U" SHAPE LAYOUT

CROSSOVER LAYOUT

STAGGERED LAYOUT

PARTNUMBER

1

2

3

4

CYLINDERSPACING

5”

10”

13”

18”

PARTNUMBER

1

2

TYPE OFMOUNTING

WALL MOUNT

FLOOR MOUNT

Gas Service

PARTNUMBER

X

C

IN

N

Q

BQ

GASSERVICE

OXYGEN

CO2

Ar, He, N2

N2O

AIR

BREATHING AIR

SEMI-AUTOMATIC MANIFOLD SYSTEMS FOR LIQUID VESSEL

5600 series manifold system is designed specifically for liquid vessels to provide an uninterrupted gas

supply. When the primary liquid vessel is depleted, the changeover takes place automatically to provide

continuous supply of gas from the reserve bank. Upon changing the cylinders, the regulators on both

banks need to be re-adjusted in order for the changover to occur automatically next time.

Semi-Automatic Manifold Systems For Liquid Vessel

14

Features

��Semi-automatic changeover control.

��Unique changeover valve provide uninterrupted supply of gas from primary and reserve banks.

��Easy Installation.

��Check valve on liquid vessel side to prevent high pressure reverse flow to liquid regulator.

��Relief valve at outlet for protecting downstream piping.

��GENTEC high flow regulator series 153M & 853MLC.

Note: The flow rate depends on the vaporization rate of gas supplied.

MODELNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

CO2

Ar, He, N2

5600X5600C5600IN

500

500

500

5~125

5~125

5~125

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA320

PIGTAIL, CGA580

www.genstartech.com

125PSIG is typical, 300PSIG models are available upon request.

15www.genstartech.com

5 6 1 2 X - 5�1 - 1

Semi-automatic manifold

system series prefix

Please follow the instructions below to select the correct

model number.

One liquid vessel (right side)Cylinder spacing

Type of mountingCylinder side

(Left Bank)layout

Number of cylinders (left side)Gas service

Manifold System Layouts

Example: 5612X-5x1-1 indicates a 5 x 1 oxygen cylinder, semi-automatic liquid vessel manifold system.

Distance between two cylinders is 10" on standard horizontal layout of left bank.

GASSERVICE

W(inch)

OXYGEN, Ar, He, N2, CO2

H1(inch)

H2(inch)

22 19 61

Standard Layout

"L" shape Layout

Type of MountingCylinder Spacing(Center to Center)

Manifold System Layout

PARTNUMBER

1

2

4

5

MANIFOLDSYSTEM LAYOUT

STANDARD LAYOUT

"L" SHAPE LAYOUT

CROSSOVER LAYOUT

STAGGERED LAYOUT

PARTNUMBER

1

2

3

4

CYLINDERSPACING

5”

10”

13”

18”

PARTNUMBER

1

2

TYPE OFMOUNTING

WALL MOUNT

FLOOR MOUNT

Gas Service

PARTNUMBER

X

C

IN

GASSERVICE

OXYGEN

CO2

Ar, He, N2

SEMI-AUTOMATIC MANIFOLD SYSTEMS FOR LIQUID VESSEL

Crossover Layout

Staggered Layout

Installation Dimension

Ordering Information

www.genstartech.com16

SEMI-AUTOMATIC MANIFOLD SYSTEMS FOR DUAL LIQUID VESSELS

5700 series manifold system is designed specifically for liquid vessels to provide an uninterrupted gas

supply. When the primary liquid vessel is depleted, the changeover takes place automatically to provide

continuous supply of gas from the reserve liquid vessel. Upon changing the vessel, the regulators on

both banks need to be re-adjusted in order for the changover to occur automatically next time.

Semi-Automatic Manifold Systems For Dual Liquid Vessel

��Semi-automatic changeover control.

��Unique changeover valve provide uninterrupted supply of gas from primary and reserve vessels .

��Check valve at outlets of regulators to prevent high pressure, reverse flow to liquid regulator.

��Easy Installation.

��Relief valve at the outlet for protecting downstream piping.

��GENTEC high flow regulator series 853MLC.

Note: The flow rate depends on the vaporization rate of gas supplied.

MODELNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

OUTLETCONNECTION

INLETDESCRIPTION

OXYGEN

CO2

Ar, He, N2

5700X5700C5700IN

500

500

500

5~125

5~125

5~125

3/4” NPT (M)

3/4” NPT (M)

3/4” NPT (M)

PIGTAIL, CGA540

PIGTAIL, CGA320

PIGTAIL, CGA580

Example: 5700X indicates oxygen dual liquid vessels manifold system.

Features

Ordering Information

125PSIG is typical, 300PSIG models are available upon request.

www.genstartech.com 17

SINGLE-SIDE & DUAL MANIFOLDSWITHOUT CYLINDER HEADER

Designed for single-side cylinder manifold systems (right or left).

Inlet connection thread: 1-11 1/2NPS RH(M).

Outlet connection thread: 3/4” NPT(M).

Max.Inlet Pressure: 3000 psig for Oxygen, CO2, Ar, He, N2, Air

400 psig for Acetylene, Propane

Designed for dual changeover manifold systems. Inlet connection thread: 1-11 1/2NPS RH(M). Outlet connection

thread: 3/4 NPT(M)

Max.Inlet Pressure: 3000 psig for Oxygen, CO2, Ar, He, N2, Air.

400 psig for Acetylene, Propane.

Dual Manifolds Without Cylinder Header

5300X-00

5200X-00R

5200X-00L

Single-Side Manifolds Without Cylinder Header

MODELNUMBER

GASSERVICE

DESCRIPTION

OXYGEN

OXYGEN

ACETYLENE

ACETYLENE

ACETYLENE

ACETYLENE

PROPANE

PROPANE

PROPANE

PROPANE

CO2

CO2

Ar, He, N2

Ar, He, N2

AIR, BREATHING AIR

AIR, BREATHING AIR

MODELNUMBER

GASSERVICE

DESCRIPTION

OXYGEN

ACETYLENE

ACETYLENE

PROPANE

PROPANE

CO2

Ar, He, N2

AIR, BREATHING AIR

5200X-00L5200X-00R5200YD-00L5200YH-00L5200YD-00R5200YH-00R5200FD-00L5200FH-00L5200FD-00R5200FH-00R5200C-00L5200C-00R5200IN-00L5200IN-00R5200Q-00L5200Q-00R

5300X-005300YD-005300YH-005300FD-005300FH-005300C-005300IN-005300Q-00

LEFT BANK with RV

RIGHT BANK with RV

LEFT BANK WITH FA (FA30PF) & RV

LEFT BANK WITH FA (GFA-1000A) & RV

RIGHT BANK WITH FA (FA30PF) & RV

RIGHT BANK WITH FA (GFA-1000A) & RV

LEFT BANK WITH FA (FA30PF) & RV

LEFT BANK WITH FA (GFA-1000LPG) & RV

RIGHT BANK WITH FA (FA30PF) & RV

RIGHT BANK WITH FA (GFA-1000LPG) & RV

LEFT BANK with RV

RIGHT BANK with RV

LEFT BANK with RV

RIGHT BANK with RV

LEFT BANK with RV

RIGHT BANK with RV

WITH FA (FA30PF) with RV

WITH FA (GFA-1000A) with RV

WITH FA (FA30PF) with RV

WITH FA (GFA-1000LPG) with RV

with RV

with RV

with RV

FA: Flashback Arrestor

RV: Relief Valve

FA: Flashback Arrestor

RV: Relief Valve

MODELNUMBER

GASSERVICE

DESCRIPTION

OXYGEN

ACETYLENE

ACETYLENE

PROPANE

PROPANE

CO2

Ar, He, N2

AIR, BREATHING AIR

H2

Designed for semi-automatic changeover manifold systems. Outlet connection thread: 3/4” NPT(M). Inlet connection

thread: 1-11 1/2NPS RH(M); Max.Inlet Pressure: 3000 psig for Oxygen, CO2, Ar, He, N2, Air; 400 psig for Acetylene,

Propane.

Semi-Automatic Manifolds Without Cylinder Hesder

5400X-00

5400X-00

5400YD-00

5400YH-00

5400FD-00

5400FH-00

5400C-00

5400IN-00

5400Q-00

5400H-00

WITH FA (FA30PF) & RV

WITH FA (GFA-1000A) & RV

WITH FA (FA30PF) & RV

WITH FA (GFA-1000LPG) & RV

WITH RV

WITH RV

WITH RV

WITH RV

SEMI-AUTOMATIC MANIFOLDS WITHOUT CYLINDER-HEADER & MANIFOLD CYLINDER-HEADER

Manifold Cylinder Header

��Machined with class "A" brass stock.

��Silver brazing on piping joints for maximum leak

prevention.

��Maximum working pressure: 3000 psig

��Inlet (Header valve): Fuel Gas - CGA510

Oxygen - CGA540

CO2 - CGA320

Ar,He,N2 - CGA580

Air - CGA590

Breathing Air - CGA346

��Outlet: 1-11 1/2NPS

��GHER, GHEL and GHEC series are designed with inlet

connection for each cylinder.

GHER-310X (right-sided manifold pipings)

GHEL-310X (left-sided manifold pipings)

GHEC-310X (dual-sided manifold pipings)

Header extension consists of a gas delivery pipe and header valves. It is expandable for different application

requirements.

Features

FA: Flashback Arrestor

RV: Relief Valve

www.genstartech.com18

www.genstartech.com 19

STATION DROPS

GSOL-2X-R

MODELNUMBER

GASSERVICE

OUTLETCONNECTION

GSOL-1X-R

GSOL-2X-R

GSOL-4X-R

GSOL-1X-H

GSOL-2X-H

GSOL-4X-H

GSOL-1IN-R

GSOL-2IN-R

GSOL-4IN-R

GSOL-1IN-H

GSOL-2IN-H

GSOL-4IN-H

GSOL-1F-R

GSOL-2F-R

GSOL-4F-R

GSOL-1F-H

GSOL-2F-H

GSOL-4F-H

Station Valve, 7/8"-14RH(M), CGA024

Station Valve, 7/8"-14RH(M), CGA024

Station Valve, 7/8"-14RH(M), CGA024

Ball Seat Valve, 9/16"-18RH(M),CGA022

Ball Seat Valve, 9/16"-18RH(M),CGA022

Ball Seat Valve,9/16"-18RH(M), CGA022

Station Valve, 7/8"-14RH(F), CGA034

Station Valve, 7/8"-14RH(F), CGA034

Station Valve, 7/8"-14RH(F), CGA034

Ball Seat Valve, 5/8"-18RH(F), CGA032

Ball Seat Valve, 5/8"-18RH(F), CGA032

Ball Seat Valve, 5/8"-18RH(F), CGA032

Station Valve, 7/8"-14LH(M), CGA025

Station Valve, 7/8"-14LH(M), CGA025

Station Valve, 7/8"-14LH(M), CGA025

Ball Seat Valve, 9/16"-18LH(M), CGA023

Ball Seat Valve, 9/16"-18LH(M), CGA023

Ball Seat Valve, 9/16"-18LH(M), CGA023

NO.OFOUTLET

1

2

4

1

2

4

1

2

4

1

2

4

1

2

4

1

2

4

==�� !"#$Station Drops

OXYGEN

OXYGEN

OXYGEN

OXYGEN

OXYGEN

OXYGEN

CO2,INLET GAS

CO2,INLET GAS

CO2,INLET GAS

CO2,INLET GAS

CO2,INLET GAS

CO2,INLET GAS

FUEL GAS

FUEL GAS

FUEL GAS

FUEL GAS

FUEL GAS

FUEL GAS

Example: GHER-210X indicates a right side oxygen manifold piping system with 2 joints, and 10" joint distance.

GHEX - X X X X

Series number

Number of joints(2/3/5)

Valve Spacing(05”/10”/13”/18”)

Gas service (X/C/IN/Q/F)

SERIESNUMBER

NUMBER OFJOINTS

JOINTDISTANCE

GAS SERVICE

2,3,5

2,3,5

2,3,5

5”10”13”18”5”

10”13”18”5”

10”13”

X: O2

C: CO2

IN: Ar, He, N2

Q: Air,

F: Acetylene

Propane

BQ: Breathing Air

GHER

GHEL

GHEC

PIPING SHAPE &LAYOUT JOINTS

Right-Side

Left-Side

Dual-Side

Ordering Infomation for Manifold Cylinder Header

singlewith ball seat valve

doublewith station valves

quadwith station valves

��GSOL series station drops are

�Inlet connection:1/2”NPT

�Station Regulators are available (page 24)

�In-Line shut-off valves (Ball Valves) are

available (page 18)

�Check valves for oxygen and fuel gases

are available (page 18)

�Labeled for Gas Service

GSOL-1 Series

GSOL-2 Series GSOL-4 Series

20 www.genstartech.com

Header Extensions

HEADER EXTENSIONS, VALVES& ACCESSORIES

GET-9X

GCC-4

GEE-11

MODELNUMBER

LENGTH INLETCONNECTION

DESCRIPTION

4-1/2”

8-1/3”

11-1/3”

8-2/3”

4”

4”

OUTLETCONNECTION

1-11 1/2 NPS-RH (M)

1-11 1/2 NPS-RH (M)

1-11 1/2 NPS-RH (M)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-RH (F)

1-11 1/2 NPS-LH (F)

GEE-4

GEE-8

GEE-11

GET-9X

GCC-4

GCC-4L Extension

Valves & Accossories

GMV-180

Master Valve

GMV-90X

Header Valve

GHFN-X Nut EN-100A Plug

GCC-A

Adaptor

GMQ-183

In-line Ball Valve

MODELNUMBER

GASSERVICE

INLET / OUTLETCONNECTION

DESCRIPTION

GMV-180

GMV-92F

GMV-92IN

GMQ-183

GMQ-184

27-CV-IL

GMV-90XGMV-90F

GMV-90C

GMV-90IN

GMV-90Q

GMV-90BQGMV-92X

*All gases = non-corrosive gases

1-11 1/2 NPS

1/2” NPT / 7/8-14 LH (M) (CGA025)

1/2” NPT / 7/8-14 RH (F) (CGA034)

1/2” NPT / 1/2” NPT

1/2” NPT / 3/4” NPT

1/2” NPT(M) / 1/2” NPT(F)

CGA540 / 1/2”NPTCGA510 / 1/2”NPT

CGA320 / 1/2”NPT

CGA580 / 1/2”NPT

CGA590 / 1/2”NPT

CGA346 / 1/2”NPT1/2” NPT / 7/8-14 RH (M) (CGA024)

*ALL GASES

O2

ACETYLENE, PROPANE

CO2

N2, Ar, He

Air

Breathing Air

O2

ACETYLENE, PROPANE

CO2, Air, N2O, Ar, He

*ALL GASES

*ALL GASES

ACETYLENE, PROPANE, O2

O2

ACETYLENE, PROPANE

CO2, Inert Gas

24-0205 1/4"NPT / 9/16-18RH (CGA022)24-0206 1/4"NPT / 9/16-18LH (CGA023)24-0215AR 1/4"NPT / 5/8-18RH (CGA032)

GMV-92X

Station Valve

24-0205

Ball Seat Valve

MASTER VALVE

HEADER VALVE

STATION VALVE

IN-LINE BALL VALVE

IN-LINE CHECK VALVE

BALL SEAT VALVES

MODELNUMBER

GASSERVICE

INLET / OUTLETCONNECTION

VENTING PRESSURE(PSI)

27-RV-Y-20

27-RV-F-40

27-RV-F-200

27-RV-IN-600

3/4” NPT

3/4” NPT

3/4” NPT

1/2” NPT

ACETYLENE

FUEL GAS

FUEL GAS

O2, Inert Gas

20

40

200

600

MODELNUMBER

DESCRIPTIONMODELNUMBER

DESCRIPTION

NUT 1-11 1/2 NPS RH (F)

NUT 1-11 1/2 NPS LH (F)

PLUG

Adaptor1/4” NPT(M) / 1-11 1/2 NPS RH (M)

Adaptor 1/4” NPT(M) / 1-11 1/2 NPS LH (M)

Adaptor 1/2” NPT(M) / 1-11 1/2 NPS RH (M)

Adaptor 1/2” NPT(M) / 1-11 1/2 NPS LH (M)

Adaptor 3/4” NPT(M) / 1-11 1/2 NPS RH (M)

Adaptor 3/4” NPT(M) / 1-11 1/2 NPS LH (M)

GHFN-X

GHFN-F

EN-100A

R155-111

R155-111A

R155-110

R155-110A

GCC-A

GCC-C

27-CV-IL

In-line Check Valve

Relief Valves

Elbow

T

21www.genstartech.com

PIGTAILS,WALL MOUNTS,PIPE HOLDERS / SUPPORTS

High Pressure Pigtails

Cylinder Wall Mounts, Pipe Holders, and Pipe Supports

GMB-7

GMB-1 GMB-3

GMB-9

GMB-6A

Note: End connectors of stainless steel tubings and pigtails are made of brass material.

( Stainless steel

braided Teflon

core pigtail )

MODELNUMBER

DESCRIPTION

GMB-1GMB-2GMB-3GMB-4

GMB-6AGMB-7GMB-9

SINGLE CYLINDER WALL MOUNT (9” wide)

SINGLE CYLINDER WALL MOUNT (14” wide)

DUAL CYLINDER WALL MOUNT (9” wide)

DUAL CYLINDER WALL MOUNT (14” wide)

PIPE SUPPORT (61”)

PIPE HOLDER Bracket

PIPE HOLDER

MODELNUMBER

GASSERVICE

INLET/OUTLETCONNECTION

LENGTH TYPE CHECKVALVE

FLASH BACKARRESTOR

��Rigid copper and flexible stainless steel braided

Teflon core pigtails are available.

��Stainless steel braided pigtails come with anti-whip armor.

��Dry Flash Back Arrestor is included in Fuel Gas Models.

��3000 PSI maximum working pressure.

OXYGEN

OXYGEN

OXYGEN

CO2

CO2

CO2

Ar,He,N2

Ar,He,N2

Ar,He,N2

Air

Air

Air

Breathing Air

Breathing Air

Breathing Air

Acetylene

Acetylene

Propane

Propane

Propane

GPF-36X-CV

GPF-24X-CV

GRP-24X-CV

GPS-36C-CV

GPS-24C-CV

GRP-24C-CV

GPS-36IN-CV

GPS-24IN-CV

GRP-24IN-CV

GPS-36Q-CV

GPS-24Q-CV

GRP-24Q-CV

GPS-36Q-CV-346

GPS-24Q-CV-346

GRP-24Q-CV-346

GPS-36Y-FA

GPS-24Y-FA

GPS-36F-FA

GPS-24F-FA

GRP-24F-FA

CGA540

CGA540

CGA540

CGA320

CGA320

CGA320

CGA580

CGA580

CGA580

CGA590

CGA590

CGA590

CGA346

CGA346

CGA346

CGA510

CGA510

CGA510

CGA510

CGA510

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

COPPER PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

COPPER PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

COPPER PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

COPPER PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

COPPER PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

FLEXIBLE STAINLESS STEEL BRAIDED PIGTAIL

COPPER PIGTAIL

36"

24"

24"

36"

24"

24"

36"

24"

24"

36"

24"

24"

36"

24"

24"

36"

24"

36"

24"

24"

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

N

N

N

N

N

N

N

N

N

N

N

N

N

N

N

Y

Y

Y

Y

Y

( Copper pigtail)

22 www.genstartech.com

FLASHBACK ARRESTORS

Hydraulic Flash Arrestor is designed for use on Acetylene or Fuel Gas Manifold Systems to protect the main

gas supply from the dangers of reverse flow and flashbacks. A pressure relief valve is included to provide

additional protection from excessive pressure.

Hydraulic Flashback Arrestors

In-line Low Pressure Flashback Arrestors

GFA-300A

Flashback Arrestor

GFS-300

Stand

Designed for use on Acetylene or Fuel Gas Manifold Systems with low pressure piping system to protect the

main gas supply from the dangers of reverse flow and flashbacks by stainless steel sintered elements and

check valves.

MODELNUMBER

GASSERVICE

FA30PFFA30P0

DELIVERYFLOW

(SCFH)

WORKINGPRESSURE

(psi)

INLETCONNECTION

OUTLETCONNECTION

ACETYLENE / PROPANE

OXYGEN15/22

145

2450

5700

3/4” NPT (F)

3/4” NPT (F)

3/4” NPT (F)

3/4” NPT (F)

MODELNUMBER

GASSERVICE

GFA-1000AGFA-1000LPGGFA-300AGFA-300LPGGFS-1000GFS-300

DELIVERY FLOW(SCFH)

1000

1000

300

300

ACETYLENE

PROPANE, LPG

ACETYLENE

PROPANE, LPG

STAND FOR GFA-1000A & GFA-1000LPG

STAND FOR GFA-300A & GFA-300LPG

FA30PO

RELIEF VALVE VENT PRESSURE(PSI)

20

40

20

40

INLET/OUTLETCONNECTION

1 1/2”NPT

1 1/2”NPT

1 1/2”NPT

1 1/2”NPT

23www.genstartech.com

FA40HPF

FLASHBACK ARRESTORS,PRESSURE SWITCHES, ALARMS

Designed for use on Acetylene or Fuel Gas Manifold Systems with high pressure piping system to protect the

main gas supply from the dangers of reverse flow and flashbacks. Stainless steel sintered elements and check

valves are constructed for additional protection.

High Pressure Flashback Arrestors

MODELNUMBER

GASSERVICE

FA40HPF

MAX.INLETPRESSURE

(psi)

INLETCONNECTION

OUTLETCONNECTION

ACETYLENE, PROPANE 400 1/4” NPT (F) 1/4” NPT (M)

Pressure switchs are designed for gas manifold systems to activate remote alarm systems. Operates when

cylinder/line pressure is below minimum pressure setting.

Pressure Switches ( Explosion-Proof Type )

Remote alarm panel is suitable for all manifold systems. The alarm is activated to provide audio and visual

warning when the service bank is empty. A press of reset button in front of the panel will silence the buzzer.

The red alarm light will remain illuminated until the empty bank is replaced.

Remote Alarm Panels

MODELNUMBER

PRESSURERANGE

(psi)

GHPS-1GHPS-2GHPS-3GHPS-4GHPS-5GHPS-6GHPS-7

MAX.INLETPRESSURE

(psi)

PRESSURECONNECTION

5~50

30~600

100~1500

400~1500

15~75

50~450

2~25

500

1500

2200

4500

1000

3000

1000

1/4” NPT

1/4” NPT

1/4” NPT

1/4” Female NPT

1/4” Female NPT

1/4” Female NPT

1/4” Female NPT

MODELNUMBER

SGPA-1SGPA-1-VSGPA-2SGPA-4

TYPE NO,OFGASES

1

1

2

4

AUDIO & VISUAL ALARM

VISUAL ALARM

AUDIO & VISUAL ALARM

AUDIO & VISUAL ALARM

EXPLOSION-PROOFTYPE

NO

NO

NO

YES

YES

YES

YES

Explosion-Proof Type

24 www.genstartech.com

191FM-60

Flowmeters

Regulator Flashback Arrestors

Designed for mounting on the regulator outlet. Internal stainless steel sintered elements and check valves

are constructed to provide protection from flashbacks.

FA7RF

FA7RO

RH14X

RH19X

Designed with a check valve to provide protection from reverse flow during gas cutting processes.

Quick Connectors with Check Valves

MODELNUMBER

GASSERVICE

RH14XRH14FRH18XRH18F

WORKINGPRESSURE

(psi)

INLETCONNECTION

OUTLETCONNECTION

OXYGEN

FUEL GAS

OXYGEN

FUEL GAS

145

30

145

30

9/16-18 RH (F)

9/16-18 LH (F)

9/16-18 RH (F)

9/16-18 LH (F)

9/16-18 RH (M)

9/16-18 LH (M)

1/4” HOSE NIPPLE

1/4” HOSE NIPPLE

Precision gas flow control for MIG and TIG welding, laboratorial, and other industrial applications. Suitable

for use on piping systems.

MODELNUMBER

GASSERVICE

FA7RFFA7RO

WORKINGPRESSURE

(psi)

INLETCONNECTION

OUTLETCONNECTION

ACETYLENE / PROPANE

OXYGEN

15/22

145

9/16-18 LH (F)

9/16-18 RH (F)

9/16-18 LH(M)

9/16-18 RH (M)

MODELNUMBER

GASSERVICE

191FM-60

191FM-60A

191FM-100

191FM-100A

191FM-70

191FM-70A

191FM-50

191FM-50A

191FM-150

191FM-150A

WORKINGPRESSURE

(psi)

INLETCONNECTION

OUTLETCONNECTION

Ar / CO2

Ar / CO2

Ar / CO2

Ar / CO2

Nitrogen / Air

Nitrogen / Air

Helium

Helium

Helium

Helium

50

50

50

50

50

50

50

50

50

50

1/4"NPT (M)

9/16"-18 RH (F)

1/4"NPT (M)

9/16"-18 RH (F)

1/4"NPT (M)

9/16"-18 RH (F)

1/4"NPT (M)

9/16"-18 RH (F)

1/4"NPT (M)

9/16"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

5/8"-18 RH (F)

REGULATORS FLASHBACK ARRESTORS,QUICK CONNECTORS & FLOW METERS

FLOWRATE

10-60SCFH

10-60SCFH

20-100SCFH

20-100SCFH

10-70SCFH

10-70SCFH

10-50SCFH

10-50SCFH

20-150SCFH

20-150SCFH

www.genstartech.com

155MY-15

591MX-750

153MC-125

155MX-125155MX-200155MY-15155MF-40155MIN-125155MIN-200155MQ-125155MQ-200155MC-125155MC-200

153MX-125153MX-200153MY-15153MF-40153MF-125153MIN-125153MIN-200153MQ-125153MQ-200153MC-125153MC-200

591MX-750591MX-1500591MX-3000591MIN-1500591MIN-3000591MQ-1500591MQ-3000

853MLCX-125853MLCCD-125853MLCIN-125

OXYGEN

ACETYLENE

LPG

Ar, He, N2

AIR

CO2

OXYGEN

ACETYLENE

LPG

Ar, He, N2

AIR

CO2

OXYGEN

Ar, He, N2

AIIR

OXYGEN

CO2

Ar, N2

5~125

10~200

2~15

2~40

5~125

10~200

5~125

10~200

5~125

10~200

5~125

10~200

2~15

2~40

5~125

5~125

10~200

5~125

10~200

5~125

10~200

50~750

100~1500

200~3000

100~1500

200~3000

100~1500

200~3000

5~125

5~125

5~125

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS LH (M)

1-11 1/2 NPS LH (M)

1-11 1/2 NPS LH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (M)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS LH (F)

1-11 1/2 NPS LH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS LH (F)

1-11 1/2 NPS LH (F)

1-11 1/2 NPS LH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

1-11 1/2 NPS RH (F)

853LC

SERIES

155M

SERIES

153M

SERIES

591-A

SERIES

MODELNUMBER

GASSERVICE

INLETCONNECTION

OUTLETCONNECTION

SERIES MAX.INLETPRESSURE

(psi)

DELIVERYPRESSURE

(psi)

3000

3000

400

400

3000

3000

3000

3000

3000

3000

3000

3000

400

400

400

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

3000

500

500

500

853MLCX-125

155M Series 153M Series 591M Series 853MLC Series

25www.genstartech.com

MANIFOLD REGULATORS

26 www.genstartech.com

STATION & LINE REGULATORS

3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)

1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)

1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)

7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 LH (F)7/8-14 LH (F)7/8-14 LH (F)

7/8-14 RH (M)7/8-14 RH (M)7/8-14 RH (M)7/8-14 RH (M)

7/8-14 LH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 LH (F)

7/8-14 LH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 RH (F)7/8-14 LH (F)

1-11 1/2 NPS LH (F)1-11 1/2 NPS RH (F)1-11 1/2 NPS LH (F)

3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)3/4” NPT (F)

1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)

1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)1/4” NPT (F)

9/16-18 RH (M)9/16-18 RH (M)9/16-18 RH (M)9/16-18 LH (M)9/16-18 LH (M)9/16-18 LH (M)5/8-18 RH (F)5/8-18 RH (F)5/8-18 RH (F)5/8-18 RH (F)

9/16-18 LH (M)9/16-18 RH (M)9/16-18 RH (M)9/16-18 RH (M)9/16-18 LH (M)

9/16-18 LH (M)5/8-18 RH (F)5/8-18 RH (F)

9/16-18 RH (M)9/16-18 RH (M)9/16-18 LH (M)

7/8-14 LH (M)7/8-14 RH (M)7/8-14 LH (M)

155LX-80155LX-125155LX-200155LY-15155LF-125155LIN-80155LIN-125155LIN-200155LQ-80155LQ-125155LQ-200155LC-125

152LX-125152LY-15152LF-80152LIN-125152LQ-125152LC-125

853LX-125853LY-15853LF-80853LF-125853LIN-125853LQ-125853LC-125

152SX-40152SX-80152SX-125152SY-15152SF-80152SF-125152SIN-40152SIN-80152SIN-125152SIN-40FG

853SF-80853SX-40853SX-80853SX-125853SY-15

853SRF-80853SRIN-80853SRIN-125853SRX-80853SRX-125853SRY-15

155SF-80155SX-125155SY-15

350350350350350350350350350350350350

350350350350350350

350350350350350350350

200200200200200200200200200200

200200200200200

200200200200200200

350350350

155LX-80

152SX-80

853SRIN-40

155L

SERIES

152L

SERIES

853L

SERIES

152S

SERIES

853S

SERIES

MODELNUMBER

GASSERVICE

MAX.INLETPRESSURE

(psi)

INLETCONNECTION

OUTLETCONNECTION

SERIES DELIVERYPRESSURE

(psi)

3~805~120

10~2002~15

5~1203~80

5~12010~200

3~805~120

10~2005~120

5~1202~153~80

5~1205~1205~120

5~1202~153~80

5~1205~1205~1205~120

2~404~80

5~1252~154~80

5~1252~404~80

5~1250~40 SCFH

4~802~404~80

5~1252~15

4~804~80

5~1254~80

5~1252~15

4~805~1252~15

155S

SERIES

853SR

SERIES

OXYGEN

ACETYLENELPG

Ar, He, N2

AIR

CO2

OXYGENACETYLENE

LPGAr, He, N2

AIRCO2

OXYGENACETYLENE

LPGAr, He, N2

AIRCO2

OXYGEN

ACETYLENE

LPG

AIRINERT GAS

CO2

LPG

OXYGEN

ACETYLENE

LPGINERT GAS

CO2

OXYGENACETYLENE

LPGOXYGEN, INERT GAS, CO2

ACETYLENE

155L Series 152S Series 853S Series

27www.genstartech.com

WARRANTY INFORMATION

Any GENTEC® apparatus found to be defective either in material or workmanship during the time set

forth below will be replaced by Genstar Technologies Company, Incorporated or its Authorized

Distributors, provided that said apparatus was used under normal conditions for the purpose intended.

Limited Warranty Period: The warranty period is as shown below, from the date of original purchase.

Product Type Warranty from the Date of Original PurchaseGas Manifold Systems 2 years

Pigtails 90 days

GENTEC® apparatus damaged or rendered inoperative due to abuse, negligence, misuse, accident

or abnormal wear and tear is not covered by this warranty and must be repaired at the sole expense

of the equipment owner. GENTEC® apparatus should be serviced or repaired by Genstar Technolo-

gies Company, Incorporated or designated service facilities only. Service or repair of this apparatus

by other than Genstar Technologies Company, Incorporated or designated service facilities may

void any warranties and relieve Genstar Technologies Company, Incorporated of any claims for

damage and/or liability.

To make a claim under this warranty, Buyer must notify Genstar Technologies Company, Incorpo-

rated or its Authorized Distributor of the details of such claim within 30 days of discovering a defect in

material or workmanship along with proof of purchase. The Buyer will be responsible for transporta-

tion costs and related risks.

Genstar Technologies Company, Incorporated shall not, under any circumstances, be liable forany damages including but not limited to: indirect, incidental, consequential, or special damages,whether such damages result from negligence, breach of warranty or otherwise.

There are no other warranties, expressed or implied, except as stated herein. This warranty gives you

specific legal rights, and you may also have other rights which vary from state to state. Genstar

Technologies Company, Incorporated reserves the right to discontinue manufacturing of any prod-

uct or change product materials, design or specifications without notice.