177 Installation Diagram Building lightningproof regional map Classification of lightningproof zone for buildings (LPZ) Primary protection for power supply (MBD1-B) Primary protection for signal circuit (MBX-RJ45) (ALT) Protector for CATV circuit (MBD-T) Secondary protection for power supply (MBD1-C) Secondary protection for signal circuit (MBX-RJ45) Protector for antenna feeder In order to distinguish the degree that lightning electromagnetic pulse(LEMP) on different lightningproof zone and the position of equal potential in the joint between different zones. The protected zone divided into several lightningproof zones (LPZ). LPZ0A zone: all objects in this zone may be strike by direct lightning and carry full lightning current, electromagnetic field strength has no attenuation. LPZ0B zone: within the relevant scope of selected grounder radius in this lightning-proof zone, the objects may not be strike by direct lightning, but electromagnetic field strength has no attenuation. LPZ1 zone: the objects in this zone are impossibly strike by lighting, lighting current on conductors and electromagnetic field strength are attenuated, the attenuation degree is determined by field solutions in the buildings. LPZ2 zone: if required to further reduce lighting current and electromagnetic field strength, it shall add extra lightningproof zone, such as machine room with shield, metal shell of equipment, machine cabinet and etc; it shall determine such zone according to ambient conditions for the protected object. Typical application of surge protective device for information building LPZ0A LEMP LPZ0A LEMP LEMP LEMP LEMP LPZ0A LPZ0B LPZ0B LPZ1 LPZ2 LPZ3 LPZ1 LPZ0A LPZ0B 1 3 2 Lightning rod External lightning protection equipment Antenna Lead referrals (Computer room) Equipment metal case, etc Shielding (3) Structures within the room (Representative shie lding 2) Buildings (Representative shielding 1) In LPZ1 and LPZ2 on the interface bonding belt Lightning zone In LPZ0B area and LPZ1 boundaries of surface bonding belt Lead referrals The electric power, the signal cable, routes and metal pipe Ground net.through introducing (door, window) Hole CATV B1 B2 C2 C1 HUb A2 A1 Satellite three line Lightning rod Grounding lead referrals Cable TV Signal cable Network cable office office office office office Receiver Server Workstations Signal the first level protection Potential spark gap Total switchgear room Points switchgear room Switch Signal the second level protection The first level protection The second level protection Logic where

Upload: meba-electric-enterprises

Post on 27-Jul-2015

80 views

Category:

Sales


2 download

TRANSCRIPT

Page 1: Surge Protective Device -Meba

177

Installation DiagramBuilding lightningproof regional map

Classification of lightningproof zone for buildings (LPZ)

Primary protection for power supply (MBD1-B)

Primary protection for signal circuit (MBX-RJ45)

(ALT) Protector for CATV circuit (MBD-T)

Secondary protection for power supply (MBD1-C)

Secondary protection for signal circuit (MBX-RJ45)

Protector for antenna feeder

In order to distinguish the degree that lightning electromagnetic

pulse(LEMP) on different lightningproof zone and the position of

equal potential in the joint between different zones. The protected

zone divided into several lightningproof zones (LPZ).

LPZ0A zone: all objects in this zone may be strike by direct lightning

and carry full lightning current, electromagnetic field strength has

no attenuation.

LPZ0B zone: withi n the relevant scope of selected grounder radius

in this lightning-proof zone, the objects may not be strike by direct

lightning, but electromagnetic field strength has no attenuation.

LPZ1 zone: the objects in this zone are impossibly strike by lighting,

lighting current on conductors and electromagnetic field strength

are attenuated, the attenuation degree is determined by field

solutions in the buildings.

LPZ2 zone: if required to further reduce lighting current and

electromagnetic field strength, it shall add extra lightningproof

zone, such as machine room with shield, metal shell of equipment,

machine cabinet and etc; it shall determine such zone according

to ambient conditions for the protected object.

Typical application of surge protectivedevice for information building

LPZ0A

LEMPLPZ0A

LEMP

LEMP

LEMP

LEMP

LPZ0A

LPZ0B

LPZ0B

LPZ1

LPZ2

LPZ3

LPZ1

LPZ0A

LPZ0B

1

3

2

Lightning rod

External lightning protection equipment

Antenna

Lead referrals

(Computer room)Equipment metal case, etcShielding (3)

Structures within the room(Representative shie lding 2)

Buildings(Representative shielding 1)

In LPZ1 and LPZ2 on the interface bonding belt

Lightning zone

In LPZ0B area and LPZ1 boundaries of surface bonding belt

Lead referrals

The electric power, the signal cable,

routes and metal pipe

Ground net.through introducing

(door, window)Hole

CATV

B1 B2

C2

C1HUb

A2

A1

Satellite three line Lightning rod

Grounding lead referrals

Cable TV

Signal cable Network cable

office office office office office

Receiver

Server

Workstations

Signal the first level protection

Potential spark gap

Total switchgear room

Points switchgear room

SwitchSignal the second level protection

Th

e firs

t leve

l p

rote

ctio

n

The second level protection

Logic where

178

N

L3

L2

L1

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60/3+NPE

MBD1-C40/3+NPE

L=5-10m L=5-10m

MBD1-D10/1+NPE

MBD1-D20/1+NPE

Up 3.0kV Up 2.0kV Up 1.5kV

TT System (1)

Total distribution ark Distribution

electricity arkEquipment place

According to different protection modes, nomenclature and definitions of IEC standard, Low voltage distribution system divided into three

kinds on basis of earthing mode of low voltage distribution system.

1. TT power supply network: TT mode is namely the protection system that metal shell of electric consumer directly earthed, calling

protective earthing system, or TT system.

2. TN power supply network: this system require metal shell of electric equipment is connected with neutral line, also calling Neutral

protection system, indicated by TN.

3. TN-C power supply network: neutral line also used as protective ea rthing wire, calling Neutral Protective earthi ng line, indicated

by NPE.

4. TN-S power supply network: neutral line (N) and protective earthing (PE) wire are separated.

5. TN-C-S power supply network: in the temporary power supply for the constructing sit e, if front supply ne twork is TN-C, and TN-S

network shall be required on local constructing sites, so PE line can be divided from general distribution box on local site.

6. IT network, I means isolation without earthing, or earthing via high resistance. Every two letters of 'T' means electric consumer of

loading side is protective earthed.

MBD Surge Protective Device(SPD) Installation diagram

Basic network of Power Supply

Page 2: Surge Protective Device -Meba

177

Installation DiagramBuilding lightningproof regional map

Classification of lightningproof zone for buildings (LPZ)

Primary protection for power supply (MBD1-B)

Primary protection for signal circuit (MBX-RJ45)

(ALT) Protector for CATV circuit (MBD-T)

Secondary protection for power supply (MBD1-C)

Secondary protection for signal circuit (MBX-RJ45)

Protector for antenna feeder

In order to distinguish the degree that lightning electromagnetic

pulse(LEMP) on different lightningproof zone and the position of

equal potential in the joint between different zones. The protected

zone divided into several lightningproof zones (LPZ).

LPZ0A zone: all objects in this zone may be strike by direct lightning

and carry full lightning current, electromagnetic field strength has

no attenuation.

LPZ0B zone: withi n the relevant scope of selected grounder radius

in this lightning-proof zone, the objects may not be strike by direct

lightning, but electromagnetic field strength has no attenuation.

LPZ1 zone: the objects in this zone are impossibly strike by lighting,

lighting current on conductors and electromagnetic field strength

are attenuated, the attenuation degree is determined by field

solutions in the buildings.

LPZ2 zone: if required to further reduce lighting current and

electromagnetic field strength, it shall add extra lightningproof

zone, such as machine room with shield, metal shell of equipment,

machine cabinet and etc; it shall determine such zone according

to ambient conditions for the protected object.

Typical application of surge protectivedevice for information building

LPZ0A

LEMPLPZ0A

LEMP

LEMP

LEMP

LEMP

LPZ0A

LPZ0B

LPZ0B

LPZ1

LPZ2

LPZ3

LPZ1

LPZ0A

LPZ0B

1

3

2

Lightning rod

External lightning protection equipment

Antenna

Lead referrals

(Computer room)Equipment metal case, etcShielding (3)

Structures within the room(Representative shie lding 2)

Buildings(Representative shielding 1)

In LPZ1 and LPZ2 on the interface bonding belt

Lightning zone

In LPZ0B area and LPZ1 boundaries of surface bonding belt

Lead referrals

The electric power, the signal cable,

routes and metal pipe

Ground net.through introducing

(door, window)Hole

CATV

B1 B2

C2

C1HUb

A2

A1

Satellite three line Lightning rod

Grounding lead referrals

Cable TV

Signal cable Network cable

office office office office office

Receiver

Server

Workstations

Signal the first level protection

Potential spark gap

Total switchgear room

Points switchgear room

SwitchSignal the second level protection

Th

e firs

t leve

l p

rote

ctio

n

The second level protection

Logic where

178

N

L3

L2

L1

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60/3+NPE

MBD1-C40/3+NPE

L=5-10m L=5-10m

MBD1-D10/1+NPE

MBD1-D20/1+NPE

Up 3.0kV Up 2.0kV Up 1.5kV

TT System (1)

Total distribution ark Distribution

electricity arkEquipment place

According to different protection modes, nomenclature and definitions of IEC standard, Low voltage distribution system divided into three

kinds on basis of earthing mode of low voltage distribution system.

1. TT power supply network: TT mode is namely the protection system that metal shell of electric consumer directly earthed, calling

protective earthing system, or TT system.

2. TN power supply network: this system require metal shell of electric equipment is connected with neutral line, also calling Neutral

protection system, indicated by TN.

3. TN-C power supply network: neutral line also used as protective ea rthing wire, calling Neutral Protective earthi ng line, indicated

by NPE.

4. TN-S power supply network: neutral line (N) and protective earthing (PE) wire are separated.

5. TN-C-S power supply network: in the temporary power supply for the constructing sit e, if front supply ne twork is TN-C, and TN-S

network shall be required on local constructing sites, so PE line can be divided from general distribution box on local site.

6. IT network, I means isolation without earthing, or earthing via high resistance. Every two letters of 'T' means electric consumer of

loading side is protective earthed.

MBD Surge Protective Device(SPD) Installation diagram

Basic network of Power Supply

Page 3: Surge Protective Device -Meba

N

L3

L2

L1

PE

MBD1-B60

MBD1-B40

L=5-10m L=5-10m

MBD1-D10

MBD1-D20

Up 3.0kV Up 2.0kV Up 1.5kV

MBD1-B100

MBD1-B80

MBD1-B65

Total distribution ark

Distribution electricity ark

Equipment place

TT System (2)

N

L3

L2

L1

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60

MBD1-C40

L=5-10m L=5-10m

MBD1-D10

MBD1-D20

Up 3.0kV Up 2.0kV Up 1.5kV

TN-S System

PE

Total distribution ark

Distribution electricity ark

Equipment place

Installation DiagramBasic network of Power Supply

N

L3

L2

L1

PE

L=5-10m L=5-10m

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60

MBD1-C40

MBD1-D10

MBD1-D20

Up 3.0kV Up 2.0kV Up 1.5kV

Total distribution ark Distribution

electricity arkEquipment place

L3

L2

L1

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60

MBD1-C40

L=5-10m L=5-10m

Up 2.0kV Up 1.8kV

Total distribution ark Distribution

electricity ark

IT System The Wiring Diagram

TN-C-S System

Installation DiagramBasic network of Power Supply

179 180

Page 4: Surge Protective Device -Meba

N

L3

L2

L1

PE

MBD1-B60

MBD1-B40

L=5-10m L=5-10m

MBD1-D10

MBD1-D20

Up 3.0kV Up 2.0kV Up 1.5kV

MBD1-B100

MBD1-B80

MBD1-B65

Total distribution ark

Distribution electricity ark

Equipment place

TT System (2)

N

L3

L2

L1

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60

MBD1-C40

L=5-10m L=5-10m

MBD1-D10

MBD1-D20

Up 3.0kV Up 2.0kV Up 1.5kV

TN-S System

PE

Total distribution ark

Distribution electricity ark

Equipment place

Installation DiagramBasic network of Power Supply

N

L3

L2

L1

PE

L=5-10m L=5-10m

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60

MBD1-C40

MBD1-D10

MBD1-D20

Up 3.0kV Up 2.0kV Up 1.5kV

Total distribution ark Distribution

electricity arkEquipment place

L3

L2

L1

PE

MBD1-B100

MBD1-B80

MBD1-B65

MBD1-B60

MBD1-C40

L=5-10m L=5-10m

Up 2.0kV Up 1.8kV

Total distribution ark Distribution

electricity ark

IT System The Wiring Diagram

TN-C-S System

Installation DiagramBasic network of Power Supply

179 180

Page 5: Surge Protective Device -Meba

MBD1-B100/80

Operation Elements Technical Parameter

108

L L L N

90

45

50

62

35

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B60

Installation

The SPD need not to be adjusted afte r

in-stalled according to requirement.

It can automatically protect the power

net-work after proper installation.

On services it need periodically check if

SPD is invalid or not, meanwhile check red

indicator of fuse lighting or not, please rep-

lace the invalid element on time.

Operation Elements

Technical Parameter

Installation

To be mounted between LPZ0A or LPZ0B

zone and LPZ1 zone, adopts 35mm standard

mountin g rail. The cross sectional area of

2multi-strand so ft copper conductor: 6 ~ 35 mm .

Generally it shall be mounted in the incoming

side of main distribution panel or box.

2Earthing wire shall be of 10mm dual color

conductor, its length not more than 500mm.

In order to eliminate the influence on normal

service of power netwo rk due SPD is invalid,

it shall add fuse or breaker to be series

connected in L line. (NB: selected according

to standard current In)

SPD as only one side of terminals, able to

prevent from being electri c touching, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal. The visible window show

white color in normal service, if to be separated

from network, it will show red color.

Maxi discharging current of each wire:

up to 100KA.

Model and specification MBD1-B60 MBD1-B80 MBD1-B100

Maxi discharging current

Nominal discharging current

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

Remarks

60 80 100

<25

IP20

Primary protection for in line

Can also picking

Maxi continuous operating voltage

Voltage protective level

750

3.5

420

2.2

385

2.0

275

1.6

420

2.5

385

2.3

320

2.0

275

1.8

420

3.0

385

3.0

320

2.5

275

2

30 40 60

Aging invalidation: white: Normal, red: invalidation

Other maxi continuous operating voltage Can be customized

MBD1 SeriesSurge Protective Device

Product introduction

MBD1 series surge protective device

(herei nafte r called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, Class I

surge protective device, it is category B

surge protective device. SPD has two

protection modes: MC and MD, SPD is in

compliance with GB18802.1/IEC61643-1

standards.

Model and Signification

MB D 1 100 385 - - -

Number of poles: 1P 2P 3P 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

-

Remote signal

B, C, D level protection

Outside Size Fig

MBD1-B SeriesSurge Protective Device

Product introduction

MBD1-B series surge protective device

(hereinafter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to pr otect from di rec t

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, Class I

surge prote -cti ve device, it is category B

surge protective device.

SPD has two protection modes: MC and MD

SPD is in compliance with GB18802.1/

IEC61643-1 standards.

In three phases and four wires system,

all three phase lines and one neutral line

to earthing line have SPD to be protected,

in normal service, the SPD is at the state

of high resistance, when network produce

surging over-voltage due to thunder or other

reasons, SPD will be conductive within

short time (ns), lead surging voltage into

ground, consequently to protect the electric

appliances of network. After surging voltage

passed by SPD, and disappeared, SPD

recover in high resistance. It will not have

influence on the normal service of network.

Outside Size Fig

91

45

L NL L

7250

62

35

MBD1-B60

Rec

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

MBD1-B60

Rec

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

MBD1-B60

Rec

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

Rec

MBD1-B60

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

Model and specification MBD1-B60 MBD1-B80

Maxi discharging current

Nominal discharging current

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

Remarks

60 80

<25

IP20

Primary protection for in line

Can also picking

Maxi continuous operating voltage

Voltage protective level

30 40

Aging invalidation: white: Normal, red: invalidation

Other maxi continuous operating voltage Can be customized

420

2.2

385

2.0

320

1.8

275

1.6

420

2.5

385

2.3

320

2.0

275

1.8

ABCN

L L L N

1

2

1

2

1

2

Principle Diagrams

Figure 1 380 V network diagram Figure 2 surge protector electrical diagram

Note: 1 heat failure from the 2 pressure sensitive resistors

181 182

Page 6: Surge Protective Device -Meba

MBD1-B100/80

Operation Elements Technical Parameter

108

L L L N

90

45

50

62

35

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B100

Rec

Uc ImaxInUp

::::

~385V100kA60kA3.0kV

GB18802.1IEC61643-1

MBD1-B60

Installation

The SPD need not to be adjusted afte r

in-stalled according to requirement.

It can automatically protect the power

net-work after proper installation.

On services it need periodically check if

SPD is invalid or not, meanwhile check red

indicator of fuse lighting or not, please rep-

lace the invalid element on time.

Operation Elements

Technical Parameter

Installation

To be mounted between LPZ0A or LPZ0B

zone and LPZ1 zone, adopts 35mm standard

mountin g rail. The cross sectional area of

2multi-strand so ft copper conductor: 6 ~ 35 mm .

Generally it shall be mounted in the incoming

side of main distribution panel or box.

2Earthing wire shall be of 10mm dual color

conductor, its length not more than 500mm.

In order to eliminate the influence on normal

service of power netwo rk due SPD is invalid,

it shall add fuse or breaker to be series

connected in L line. (NB: selected according

to standard current In)

SPD as only one side of terminals, able to

prevent from being electri c touching, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal. The visible window show

white color in normal service, if to be separated

from network, it will show red color.

Maxi discharging current of each wire:

up to 100KA.

Model and specification MBD1-B60 MBD1-B80 MBD1-B100

Maxi discharging current

Nominal discharging current

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

Remarks

60 80 100

<25

IP20

Primary protection for in line

Can also picking

Maxi continuous operating voltage

Voltage protective level

750

3.5

420

2.2

385

2.0

275

1.6

420

2.5

385

2.3

320

2.0

275

1.8

420

3.0

385

3.0

320

2.5

275

2

30 40 60

Aging invalidation: white: Normal, red: invalidation

Other maxi continuous operating voltage Can be customized

MBD1 SeriesSurge Protective Device

Product introduction

MBD1 series surge protective device

(herei nafte r called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, Class I

surge protective device, it is category B

surge protective device. SPD has two

protection modes: MC and MD, SPD is in

compliance with GB18802.1/IEC61643-1

standards.

Model and Signification

MB D 1 100 385 - - -

Number of poles: 1P 2P 3P 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

-

Remote signal

B, C, D level protection

Outside Size Fig

MBD1-B SeriesSurge Protective Device

Product introduction

MBD1-B series surge protective device

(hereinafter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to pr otect from di rec t

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, Class I

surge prote -cti ve device, it is category B

surge protective device.

SPD has two protection modes: MC and MD

SPD is in compliance with GB18802.1/

IEC61643-1 standards.

In three phases and four wires system,

all three phase lines and one neutral line

to earthing line have SPD to be protected,

in normal service, the SPD is at the state

of high resistance, when network produce

surging over-voltage due to thunder or other

reasons, SPD will be conductive within

short time (ns), lead surging voltage into

ground, consequently to protect the electric

appliances of network. After surging voltage

passed by SPD, and disappeared, SPD

recover in high resistance. It will not have

influence on the normal service of network.

Outside Size Fig

91

45

L NL L

7250

62

35

MBD1-B60

Rec

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

MBD1-B60

Rec

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

MBD1-B60

Rec

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

Rec

MBD1-B60

Uc: Imax:In:Up:

~385V60kA30kA

2.0kV

GB18802.1IEC61643-1

Model and specification MBD1-B60 MBD1-B80

Maxi discharging current

Nominal discharging current

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

Remarks

60 80

<25

IP20

Primary protection for in line

Can also picking

Maxi continuous operating voltage

Voltage protective level

30 40

Aging invalidation: white: Normal, red: invalidation

Other maxi continuous operating voltage Can be customized

420

2.2

385

2.0

320

1.8

275

1.6

420

2.5

385

2.3

320

2.0

275

1.8

ABCN

L L L N

1

2

1

2

1

2

Principle Diagrams

Figure 1 380 V network diagram Figure 2 surge protector electrical diagram

Note: 1 heat failure from the 2 pressure sensitive resistors

181 182

Page 7: Surge Protective Device -Meba

MBD1-C40

Installation

To be mounted between LPZ0B or LPZ1 zone

and LPZ2 zone, adopts 35mm standard

mounting rail. The cross sectional area of

multi-strand soft copper conductor: 2.5~352mm .

Every phase of SPD shall be protected b y

fuse or mini circuit breaker from short circuit

when SPD is broken down caused by surging

voltage.

It is mounted in distribution boxes of different

floors, computer center, telecommunication

room, control room of elevator, CATV room,

fire fighting center, distribution box of villa

and etc.

ABCN

L L L N

1

2

1

2

1

2

Principle Diagrams

Figure 1 380 V network diagram

Figure 2 surge protector electrical diagramNote: 1 heat failure from the 2 pressure sensitive resistors

MBD1-D20

Principle Diagrams

91

45

L NL L

7250

62

35

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C SeriesSurge Protective Device

Product introduction

Outside Size Fig

MBD1-C series surge protective device

(hereinafter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from dir ect

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1: 1998-02 standard, Class II

surge prote-ctive device, it is category C

surge protective device.

SPD has two protection modes: MC and MD

SPD is in compliance with GB18802.1/

IEC61643-1 standards.

Operation Elements

SPD as only one side of terminals, able to prevent from being electric touch ing, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD is invalid due to overheating or breakdown,

the disconnector can automatically separate SPD from the network, meanwhile send

an indication signal. The visible window show white color in normal service, if to be

sepa-rated from network, it will show red color.

1P+N, 2P+N, 3P+N SPD consist of 1P 2P 3P SPD and NPE neutral and earthing

protection modules, used in the power supply system of TN-S, TN-C-S and etc.

Technical Parameter

Other maxi continuous operating voltage Can be customized

Can also picking

Secondary protection for in line

20

750

3.0

420

2.0

385

1.8

320

1.6

275

1.5

175

1.3

48

0.6

<25

IP20

40

Aging invalidation: white: Normal, red: invalidation

MBD1-C40

Remarks

Remote signal Function

Application

Indication of invalidation

Protection grade

Model and specification

Maxi discharging current

Nominal discharging current

Response time

Voltage protective level

Maxi continuous operating voltage

L/N

M1

V

t

V: high-energy MOV

Ft: Large current fusing

t : Hot open circuit device

M I: Open circuit instructions device

Red failure, White normal

MBD1-D SeriesSurge Protective Device

Outside Size Fig

Product introduction

MBD1-D series surge protective device

(hereinafter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, C lass III

surge protective device, it is category D

surge protective device.

SPD has two protection modes: MC and MD

SPD is in compliance with GB18802.1/

IEC61643-1 standards

Installation

To be mounted between LPZ1 or LPZ2 zone

and LPZ3 zone, adopts 35mm standard

mounting rail. The cross sectional area of

multi-strand soft copper conductor : 2.5~ 35

2mm .

Every pole of MBD shall be protected by fuse

or mini circuit breaker.

It is mounted in distri bution boxes of living

house, computer center, communication

equipment, electronic equipment and control

equipment or nearest socket box.

91

45

L NL L

7250

62

35

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

Operation Elements

SPD as only one side of terminals, able to prevent from being electric touching, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD is invalid due to overheating or breakdown,

the disconnector can automatically separate SPD from the network, meanwhile

send an indicatio n signa l. The visi ble window show white color in normal service,

if to be sepa-rated from network, it will show red color.

1P+N, 2P +N, 3P+N SPD consist of 1P 2P 3P SPD and NPE neutral and earthing

protection modules, used in the power supply system of TN-S , TN-C-S and et c.

Technical Parameter

Model and specification

Other maxi continuous operating voltage Can be customized

Can also picking

Several protection for in line

Aging invalidation: white: Normal, red: invalidation

IP20

<25

Remarks

Remote signal Function

Application

Indication of invalidation

Protection grade

Response time

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operating voltage 420

1.8

385

1.5

320

1.4

275

1.2

420

1.6

385

1.3

320

1.2

275

1.0

750

2.5

750

2.0

20

10

10

5

MBD1-D20 MBD1-D10

183 184

Page 8: Surge Protective Device -Meba

MBD1-C40

Installation

To be mounted between LPZ0B or LPZ1 zone

and LPZ2 zone, adopts 35mm standard

mounting rail. The cross sectional area of

multi-strand soft copper conductor: 2.5~352mm .

Every phase of SPD shall be protected b y

fuse or mini circuit breaker from short circuit

when SPD is broken down caused by surging

voltage.

It is mounted in distribution boxes of different

floors, computer center, telecommunication

room, control room of elevator, CATV room,

fire fighting center, distribution box of villa

and etc.

ABCN

L L L N

1

2

1

2

1

2

Principle Diagrams

Figure 1 380 V network diagram

Figure 2 surge protector electrical diagramNote: 1 heat failure from the 2 pressure sensitive resistors

MBD1-D20

Principle Diagrams

91

45

L NL L

7250

62

35

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C SeriesSurge Protective Device

Product introduction

Outside Size Fig

MBD1-C series surge protective device

(hereinafter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from dir ect

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1: 1998-02 standard, Class II

surge prote-ctive device, it is category C

surge protective device.

SPD has two protection modes: MC and MD

SPD is in compliance with GB18802.1/

IEC61643-1 standards.

Operation Elements

SPD as only one side of terminals, able to prevent from being electric touch ing, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD is invalid due to overheating or breakdown,

the disconnector can automatically separate SPD from the network, meanwhile send

an indication signal. The visible window show white color in normal service, if to be

sepa-rated from network, it will show red color.

1P+N, 2P+N, 3P+N SPD consist of 1P 2P 3P SPD and NPE neutral and earthing

protection modules, used in the power supply system of TN-S, TN-C-S and etc.

Technical Parameter

Other maxi continuous operating voltage Can be customized

Can also picking

Secondary protection for in line

20

750

3.0

420

2.0

385

1.8

320

1.6

275

1.5

175

1.3

48

0.6

<25

IP20

40

Aging invalidation: white: Normal, red: invalidation

MBD1-C40

Remarks

Remote signal Function

Application

Indication of invalidation

Protection grade

Model and specification

Maxi discharging current

Nominal discharging current

Response time

Voltage protective level

Maxi continuous operating voltage

L/N

M1

V

t

V: high-energy MOV

Ft: Large current fusing

t : Hot open circuit device

M I: Open circuit instructions device

Red failure, White normal

MBD1-D SeriesSurge Protective Device

Outside Size Fig

Product introduction

MBD1-D series surge protective device

(hereinafter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, C lass III

surge protective device, it is category D

surge protective device.

SPD has two protection modes: MC and MD

SPD is in compliance with GB18802.1/

IEC61643-1 standards

Installation

To be mounted between LPZ1 or LPZ2 zone

and LPZ3 zone, adopts 35mm standard

mounting rail. The cross sectional area of

multi-strand soft copper conductor : 2.5~ 35

2mm .

Every pole of MBD shall be protected by fuse

or mini circuit breaker.

It is mounted in distri bution boxes of living

house, computer center, communication

equipment, electronic equipment and control

equipment or nearest socket box.

91

45

L NL L

7250

62

35

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

Operation Elements

SPD as only one side of terminals, able to prevent from being electric touching, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD is invalid due to overheating or breakdown,

the disconnector can automatically separate SPD from the network, meanwhile

send an indicatio n signa l. The visi ble window show white color in normal service,

if to be sepa-rated from network, it will show red color.

1P+N, 2P +N, 3P+N SPD consist of 1P 2P 3P SPD and NPE neutral and earthing

protection modules, used in the power supply system of TN-S , TN-C-S and et c.

Technical Parameter

Model and specification

Other maxi continuous operating voltage Can be customized

Can also picking

Several protection for in line

Aging invalidation: white: Normal, red: invalidation

IP20

<25

Remarks

Remote signal Function

Application

Indication of invalidation

Protection grade

Response time

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operating voltage 420

1.8

385

1.5

320

1.4

275

1.2

420

1.6

385

1.3

320

1.2

275

1.0

750

2.5

750

2.0

20

10

10

5

MBD1-D20 MBD1-D10

183 184

Page 9: Surge Protective Device -Meba

MBD1-RC40 MBD1-D20-N-PE

91

45

L

N

L L

7250

62

35

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

N-PE

Uc: Imax:Up:

~255V40kA(8/20)

1.1kV

GB18802.1IEC61643-1

MBD1-R SeriesFuse Combination Surge Protective Device

MB D 1- R / / /

Enterprise code

Surge Protective Device(SPD)

Design No

Maxi discharging current Imax(8/20 s)(kA)

Maxi continuous operating voltage Uc(V)

Remote signal

Fuse Combination

Number of poles: 1P, 2P, 3P, 4P 1P+NPE, 3P+NPE

Features Technical Parameter

Product introduction Model and Signification

In order to meet with user demand, we

developed new generation MBD1-R series

protector with built- in circuit breaking

devi ce, to limit surge current, overvoltage,

over-current occurred in the power system

due to some reasons, working in the system

of AC 50Hz, rated voltage 380V and bel ow

to prevent surge voltage from damaging

electric equipment.

MBD1-R series protector has integrated

short circuit protective function in its SPD

module, fuse not needed again, it can be

mounted on 35mm railway, compared with

normal combination of fuse + SPD module,

there has following advantages:

Residual voltage reduce more than 50%, for

normal combination, fuse body and connected

conductor have inductance, and will result

in residual voltage, but MBD1-R series

almos t has no residual voltage at this case,

therefore it can get better result of protecting

equipment.

Easy installation, saving space, saving

installation cost in cabinet.

Quicker response speed, comprehensive

performance being improved.

Better N point: no matter which step of circuit,

there has shortest distance for discharging

surge current, residual voltage decrease more.

Model and specification MBD1-RB60MBD1-RC40MBD1-RD20MBD1-RD10

AC220V/AC380V

AC385V/AC420V

30

60

40

20

20

10

10

5

1.8/2.01.5/1.81.2/1.51.0/1.2

1P 2P 3P 4P 1P+NPE 3P+NPE

25ns

Ip20

Rated working voltage Un(AC)

Maxin continuous operating voltage

Nominal discharging current In

Max discharging current Imax

Protective level Up (kV)

Pole combination

Response time tA

Outline size mm (Lx H x W)

Protective grade

Indication of invalidation

Remote signaling function Able to provide if required.

Aging invalidation: white: Normal, red: invalidationShort circuit invalidation: red LED shining.

135*73*18n Pole number

MBD1-RB80

40

80

2.0/2.5

RemarkOther maxi continuous working voltage Uc (AC) 175V 275V

320V, can be supplied if required.

Technical Parameter

N-PE SeriesSurge Protective Device

Product introduction

Outside Size Fig

L1L2L3N

PE

L

N

PE

Figure 1 Figure 2

Principle Diagrams

N-PE surge protective device module

(here inaft er called SPD) is suitable for

the "3+1" circuit protected mode TT system

of AC 50/60Hz, rated voltage up to 380V,

used in bet ween equal potential system

of neutral and PE l ine, to protect from

direct and indirect lightning impulse and

other transient over voltage. If cooperated

with MBD1-C40 series surge protec tive

device, i t is constructed as 1P+1NPE;

2P+NPE, 3P+NPE combined SPD, this

is to improve the surg ing protect ive

performance. As per the condit ions of

IEC61643-1:1998-02 standard, Class II

surge protective device, it is category C

surge protective device.

N-PE meets with GB18802.1/IEC61643-1

standards.

Operation Elements

The main operating element of NPE is gas

discharging tube or air discharging gap, ge-

nerally, it is high resistance between electr-

odes, while the surge of direct and indirect

lightning impulse and other transient over

voltage influence on the power network, the

SPD between electrodes will be conductive

within short time (ns) , and leading surging

current into ground, consequently to protect

the electric appliances of network. After

surging voltage passed by NPE, and disa-

ppeared, NPE recovers in high resistance.

It will not have influence on the normal

service of network.

Installation

NPE and MBD1-C series surge protective

devices forms MBD1-40-1P+N, 2PN, 3+P+N

and etc SPD, with MC and MD protection

modes.

NPE adopt s 35mm standard mounting rail. 2Neutral line is of 2.5~ 35 mm conductor,

eart hing wire shall be dual color multi-2strand copper conductor of more than 4 mm ,

the length not more than 500mm.

Maxi continuous operating voltage

Model and specification

Voltage protective level

Remarks

Remote signal Function

Application

Protection grade

Response time

Maxi discharging current

Nominal discharging current

Indication of invalidation

Other maxi continuous operating voltage Can be customized

Can also picking

Aging invalidation: white: Normal, red: invalidation

Several protection for in line

IP20

25

20

40

MBD1-NPE

L-N

N-PE

L-N

N-PE

420

2.0

385

1.8

320

1.6

275

1.5

1.2

255

185 186

Page 10: Surge Protective Device -Meba

MBD1-RC40 MBD1-D20-N-PE

91

45

L

N

L L

7250

62

35

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

MBD1-D20

Rec

Uc: Imax:In:Up:

~385V20kA10kA

1.5kV

GB18802.1IEC61643-1

N-PE

Uc: Imax:Up:

~255V40kA(8/20)

1.1kV

GB18802.1IEC61643-1

MBD1-R SeriesFuse Combination Surge Protective Device

MB D 1- R / / /

Enterprise code

Surge Protective Device(SPD)

Design No

Maxi discharging current Imax(8/20 s)(kA)

Maxi continuous operating voltage Uc(V)

Remote signal

Fuse Combination

Number of poles: 1P, 2P, 3P, 4P 1P+NPE, 3P+NPE

Features Technical Parameter

Product introduction Model and Signification

In order to meet with user demand, we

developed new generation MBD1-R series

protector with built- in circuit breaking

devi ce, to limit surge current, overvoltage,

over-current occurred in the power system

due to some reasons, working in the system

of AC 50Hz, rated voltage 380V and bel ow

to prevent surge voltage from damaging

electric equipment.

MBD1-R series protector has integrated

short circuit protective function in its SPD

module, fuse not needed again, it can be

mounted on 35mm railway, compared with

normal combination of fuse + SPD module,

there has following advantages:

Residual voltage reduce more than 50%, for

normal combination, fuse body and connected

conductor have inductance, and will result

in residual voltage, but MBD1-R series

almos t has no residual voltage at this case,

therefore it can get better result of protecting

equipment.

Easy installation, saving space, saving

installation cost in cabinet.

Quicker response speed, comprehensive

performance being improved.

Better N point: no matter which step of circuit,

there has shortest distance for discharging

surge current, residual voltage decrease more.

Model and specification MBD1-RB60MBD1-RC40MBD1-RD20MBD1-RD10

AC220V/AC380V

AC385V/AC420V

30

60

40

20

20

10

10

5

1.8/2.01.5/1.81.2/1.51.0/1.2

1P 2P 3P 4P 1P+NPE 3P+NPE

25ns

Ip20

Rated working voltage Un(AC)

Maxin continuous operating voltage

Nominal discharging current In

Max discharging current Imax

Protective level Up (kV)

Pole combination

Response time tA

Outline size mm (Lx H x W)

Protective grade

Indication of invalidation

Remote signaling function Able to provide if required.

Aging invalidation: white: Normal, red: invalidationShort circuit invalidation: red LED shining.

135*73*18n Pole number

MBD1-RB80

40

80

2.0/2.5

RemarkOther maxi continuous working voltage Uc (AC) 175V 275V

320V, can be supplied if required.

Technical Parameter

N-PE SeriesSurge Protective Device

Product introduction

Outside Size Fig

L1L2L3N

PE

L

N

PE

Figure 1 Figure 2

Principle Diagrams

N-PE surge protective device module

(here inaft er called SPD) is suitable for

the "3+1" circuit protected mode TT system

of AC 50/60Hz, rated voltage up to 380V,

used in bet ween equal potential system

of neutral and PE l ine, to protect from

direct and indirect lightning impulse and

other transient over voltage. If cooperated

with MBD1-C40 series surge protec tive

device, i t is constructed as 1P+1NPE;

2P+NPE, 3P+NPE combined SPD, this

is to improve the surg ing protect ive

performance. As per the condit ions of

IEC61643-1:1998-02 standard, Class II

surge protective device, it is category C

surge protective device.

N-PE meets with GB18802.1/IEC61643-1

standards.

Operation Elements

The main operating element of NPE is gas

discharging tube or air discharging gap, ge-

nerally, it is high resistance between electr-

odes, while the surge of direct and indirect

lightning impulse and other transient over

voltage influence on the power network, the

SPD between electrodes will be conductive

within short time (ns) , and leading surging

current into ground, consequently to protect

the electric appliances of network. After

surging voltage passed by NPE, and disa-

ppeared, NPE recovers in high resistance.

It will not have influence on the normal

service of network.

Installation

NPE and MBD1-C series surge protective

devices forms MBD1-40-1P+N, 2PN, 3+P+N

and etc SPD, with MC and MD protection

modes.

NPE adopt s 35mm standard mounting rail. 2Neutral line is of 2.5~ 35 mm conductor,

eart hing wire shall be dual color multi-2strand copper conductor of more than 4 mm ,

the length not more than 500mm.

Maxi continuous operating voltage

Model and specification

Voltage protective level

Remarks

Remote signal Function

Application

Protection grade

Response time

Maxi discharging current

Nominal discharging current

Indication of invalidation

Other maxi continuous operating voltage Can be customized

Can also picking

Aging invalidation: white: Normal, red: invalidation

Several protection for in line

IP20

25

20

40

MBD1-NPE

L-N

N-PE

L-N

N-PE

420

2.0

385

1.8

320

1.6

275

1.5

1.2

255

185 186

Page 11: Surge Protective Device -Meba

MBD1A-C

With sound and light alarm module appearance and size (mm)

MBD2-40

Operation Elements

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal. The visible window show

white color in normal service, if to be sepa-

rated from network, it will show red color.

Installation

To be mounted between LPZOB or LPZ1

zone and LPZ2 zone, adopts 35mm st andard

mounting rai l. The cross sectional area of

multi -strand sof t copper conductor: 2.5~

235 mm .

Every pole of SPD shall be protected by

fuse or mini circuit breaker. As required, the

user can assemble single pole or three poles

surge protective device freely.

Technical Parameter

Model and specification

Maxi carrying capacity

Nomial carrying capacity

MBD1S-B MBD1S-C MBD1S-D

80

40

60

30

40

20

20

10

10

5

Technical Parameter

Model and specification

Maxi carrying capacity

Nomial carrying capacity

MBD1A-B MBD1A-C MBD1A-D

80

40

60

30

40

20

20

10

10

5

MBD1S-C series remote sign-aling surge protective device

MBD1S/A-C SeriesRemote Signaling/ Acoustic-optical Alarm Surge Protective Device

Product introduction Model and Signification

The acoustic-optical alarm module shall

operate with module surge protective

device, used in AC 50/60Hz, 220V/385V

power supply system, the protection grade

and number of poles (1P 2P 3P 4P) ar e

determined by user.

Once power source module is out of oper-

ation, acoustic alarm sounds, red LED

flash, meanwhile it will give a command

signal to a terminal for alarm against

in va li di ty, which has NO, NC contacts,

namely NC marked with 1, 2, NO marked

with 1, 3; while alarming, push black button

to cancel the alarm sound temporarily, red

LED continue flashing, if fault module is not

replaced, the acoustic alarm will sound

again , afte r to replace the fault module, red

LED go out, SPD return to normal operation.

Disconnector built in SPD, when SPD is

inva lid due to breakdown come from over

heating, over-current, the disconnector

will cut of f the SPD automatically and give

indication signal of changed color. When

SPD work normally, the visible window of

module will show green, once invalid, it w ill

show red, and produce acousticoptical

alarm via connecting rod on the base, indi-

cating the status of SPD is in normal service,

aging, tripped temperature fuse or over-

current and etc.

Enterprise code

Surge Protective Device(SPD)

S: Output of remote signal

A: Output of acoustic-optical alarm

MB D 1 A/S - B /C

Protected Category

Design No

MBD1A-C series acoustic-optical alarm surge protective device

Disconnector built in SPD, when SPD is in-valid due to breakdown come from over-

heatin g, over-current, the disconnector will cut of f the SPD automatically and give

indication signal of c hanged color. When SPD work normally, the visible window of

modul e will show g reen, o nce in vali d, it wi ll show r ed, and produce acousticoptical

alarm via con- necting rod on the base, indicating the status of SPD i s in no rmal se rvice,

aging, tripped temperature fuse or over-current and etc.

2 3 2 3

1 1

L L L NL N

90

18

62

5018

90

45

35

Buzzer

Power

Reset

24 Hour

LED Arrester

1 2 3

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

Normal Failure

MB D 2 65 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Outside Size Fig

6550

45

35

N L1 L2 L3

72

18

91

57

45

C40

Red: Replace

Imax:In:Up:Uc:

40kA20kA1.5kV340V~

MBD2

GB18802.1

C40

Red: Replace

Imax:In:Up:Uc:

40kA20kA1.5kV340V~

MBD2

GB18802.1

C40

Red: Replace

Imax:In:Up:Uc:

40kA20kA1.5kV340V~

MBD2

GB18802.1

C40

Red: Replace

MBD2

GB18802.1

MBD2 SeriesSurge Protective Device

Product introduction Model and Signification

MBD2 series surge protector (hereinafter

referred to as the SPD) is in absorbing

foreign advanced technology research and

development on the basis of new replaceable

type SPD.

SPD is suitable for use in ac 50/60 Hz ac

rated voltage 380 V, below the power supply

system of indirect or direct lightning, the

lightning influence or other instanta neous

overvoltage protection.

SPD has common mode (MC) and dif ferential

mode (MD) protection way.

SPD accord with GB18802.1 / IEC61643-1.Technical Parameter

Can also picking

Protection for in line

Aging invalidation: white: Normal, red: invalidation

Model and specification

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

IP20

<25

Nominal discharging current

Maxi discharging current

Voltage protective level

420

2.5

MBD2-65

275

2.0

65

30

40

15

15

5

8

2

275

0.8

420

1.2

275

1.0

420

1.5

275

1.2

420

2.0

MBD2-40 MBD2-15 MBD2-8

Maxi continuous operating voltage

187 188

Page 12: Surge Protective Device -Meba

MBD1A-C

With sound and light alarm module appearance and size (mm)

MBD2-40

Operation Elements

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal. The visible window show

white color in normal service, if to be sepa-

rated from network, it will show red color.

Installation

To be mounted between LPZOB or LPZ1

zone and LPZ2 zone, adopts 35mm st andard

mounting rai l. The cross sectional area of

multi -strand sof t copper conductor: 2.5~

235 mm .

Every pole of SPD shall be protected by

fuse or mini circuit breaker. As required, the

user can assemble single pole or three poles

surge protective device freely.

Technical Parameter

Model and specification

Maxi carrying capacity

Nomial carrying capacity

MBD1S-B MBD1S-C MBD1S-D

80

40

60

30

40

20

20

10

10

5

Technical Parameter

Model and specification

Maxi carrying capacity

Nomial carrying capacity

MBD1A-B MBD1A-C MBD1A-D

80

40

60

30

40

20

20

10

10

5

MBD1S-C series remote sign-aling surge protective device

MBD1S/A-C SeriesRemote Signaling/ Acoustic-optical Alarm Surge Protective Device

Product introduction Model and Signification

The acoustic-optical alarm module shall

operate with module surge protective

device, used in AC 50/60Hz, 220V/385V

power supply system, the protection grade

and number of poles (1P 2P 3P 4P) ar e

determined by user.

Once power source module is out of oper-

ation, acoustic alarm sounds, red LED

flash, meanwhile it will give a command

signal to a terminal for alarm against

in va li di ty, which has NO, NC contacts,

namely NC marked with 1, 2, NO marked

with 1, 3; while alarming, push black button

to cancel the alarm sound temporarily, red

LED continue flashing, if fault module is not

replaced, the acoustic alarm will sound

again , afte r to replace the fault module, red

LED go out, SPD return to normal operation.

Disconnector built in SPD, when SPD is

inva lid due to breakdown come from over

heating, over-current, the disconnector

will cut of f the SPD automatically and give

indication signal of changed color. When

SPD work normally, the visible window of

module will show green, once invalid, it w ill

show red, and produce acousticoptical

alarm via connecting rod on the base, indi-

cating the status of SPD is in normal service,

aging, tripped temperature fuse or over-

current and etc.

Enterprise code

Surge Protective Device(SPD)

S: Output of remote signal

A: Output of acoustic-optical alarm

MB D 1 A/S - B /C

Protected Category

Design No

MBD1A-C series acoustic-optical alarm surge protective device

Disconnector built in SPD, when SPD is in-valid due to breakdown come from over-

heatin g, over-current, the disconnector will cut of f the SPD automatically and give

indication signal of c hanged color. When SPD work normally, the visible window of

modul e will show g reen, o nce in vali d, it wi ll show r ed, and produce acousticoptical

alarm via con- necting rod on the base, indicating the status of SPD i s in no rmal se rvice,

aging, tripped temperature fuse or over-current and etc.

2 3 2 3

1 1

L L L NL N

90

18

62

5018

90

45

35

Buzzer

Power

Reset

24 Hour

LED Arrester

1 2 3

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

MBD1-C40

Rec

Uc: Imax:In:Up:

~385V40kA20kA

1.8kV

GB18802.1IEC61643-1

Normal Failure

MB D 2 65 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Outside Size Fig

6550

45

35

N L1 L2 L3

72

18

91

57

45

C40

Red: Replace

Imax:In:Up:Uc:

40kA20kA1.5kV340V~

MBD2

GB18802.1

C40

Red: Replace

Imax:In:Up:Uc:

40kA20kA1.5kV340V~

MBD2

GB18802.1

C40

Red: Replace

Imax:In:Up:Uc:

40kA20kA1.5kV340V~

MBD2

GB18802.1

C40

Red: Replace

MBD2

GB18802.1

MBD2 SeriesSurge Protective Device

Product introduction Model and Signification

MBD2 series surge protector (hereinafter

referred to as the SPD) is in absorbing

foreign advanced technology research and

development on the basis of new replaceable

type SPD.

SPD is suitable for use in ac 50/60 Hz ac

rated voltage 380 V, below the power supply

system of indirect or direct lightning, the

lightning influence or other instanta neous

overvoltage protection.

SPD has common mode (MC) and dif ferential

mode (MD) protection way.

SPD accord with GB18802.1 / IEC61643-1.Technical Parameter

Can also picking

Protection for in line

Aging invalidation: white: Normal, red: invalidation

Model and specification

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

IP20

<25

Nominal discharging current

Maxi discharging current

Voltage protective level

420

2.5

MBD2-65

275

2.0

65

30

40

15

15

5

8

2

275

0.8

420

1.2

275

1.0

420

1.5

275

1.2

420

2.0

MBD2-40 MBD2-15 MBD2-8

Maxi continuous operating voltage

187 188

Page 13: Surge Protective Device -Meba

MBD3-40/120

Operation ElementsTechnical Parameter

MBD4-40

Installation

L L L N

72

10

0 90

45

66

51

35MBD4-C

Uc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

MBD4-CUc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

MBD4-CUc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

MBD4-CUc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

Outside Size Fig

MBD3 SeriesSurge Protective Device

Product introduction Model and Signification

MBD3- B series surge protective device

(hereinaf ter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, Cla ss I

surge protective device, it is category B

surge protective device.

SPD meets with GB18802.1/IEC61643-1

standards.

Installation

Category B surge protective device (SPD),

used in the connection between equal pot-

ential electrodes while thunder occur.

To be mounted: between LPZ0A or LPZ0B

zone and LPZ1 zone, adopts 35mm standard

mounting rail. The cross sectional area of

2multi-strand soft copper conductor: 2.5~35mm.

Generally to be installed in low voltage main

incoming distribution panel, overhead incoming.

As required, the user can assemble single pole

or three poles surge protective device freely.

Generally to be installed in low voltage main

incoming distribution panel, earthing wire

shall be dual color multi-strand soft copper

2conductor more than 16 mm

MB D 3 120 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Single pole structure, single pole or three

poles combined SPD available.

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal.

The visible window show white color in normal

service, if to be separated from network, it

will show red color. It can adopt Kelvin wiring

mode. Large current carrying capacity, fast

response time, low residual voltage.

Model and specification

Voltage protective level

<25

IP20

Maxi discharging current

Nominal discharging current

Response time

Application

Protection grade

Indication of invalidation

420

2.5

275

1.8

420

2.8

275

2.0

420

3.0

275

2.0

Protection for in line

Aging invalidation: white: Normal, red: invalidation

420

2.5

275

1.5

420

1.8

275

1.5

80 100 120654515

40 50 6030155

MBD3-80 MBD3-100 MBD3-120MBD3-65MBD3-40MBD3-15

420

1.2

275

1.0

Maxi continuous operating voltage

69

46

35

36

87

57

45

Uc: 385V

Imax:120kA(8/20)

In: 60kA(8/20)

Up : 3.0kV

Ref.8144-03-03

RecRec

Imax:40kA

Uc: 420V

In : 15kA

UP:1.8kV

MBD3-40

18

87

58 45

MBD3-40

Outside Size Fig

Product introduction Model and Signification

MBD4 series surge protective device

(hereinafter called SPD) is sui-tably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage.

SPD meets with GB18802.1/IEC61643-1

standard.

MBD4 SeriesSurge Protective Device

Operation Elements

SPD as only one side of terminals, able to

prevent from being electric touching, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal. The visible window show

white color in normal service, if to be sepa-

rated from network, it will show red color.

Fast response time, low residual voltage.

To be mounted in joint of LPZ1 or LPZ2 zone,

adopts 35mm standard mounting rail. The

cross sectional area of multi-strand soft

2copper conductor: 2.5~ 35 mm .

Every pole of SPD shall be protected by fuse

or mini circuit breaker.

The Contact

SPD can provide the NO contact for remote

communication, if one or more modules of

SPD is invalid, the NO and NC contact will

be closed and send fault information.

MB D 4 40 385 - -

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Technical Parameter

Remarks

Remote signal Function

Application

Indication of invalidation

Protection grade

Response time

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operating voltage

Model and specification

Other maxi continuous working voltage Uc (AC) can be supplied if required.

<25

IP20

Protection for in line

Can also picking

Aging invalidation: white: Normal, red: invalidation

20

10

40

20

420

1.8

275

1.2

420

2.0

275

1.5

MBD4-20 MBD4-40

189 190

Page 14: Surge Protective Device -Meba

MBD3-40/120

Operation ElementsTechnical Parameter

MBD4-40

Installation

L L L N

72

10

0 90

45

66

51

35MBD4-C

Uc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

MBD4-CUc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

MBD4-CUc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

MBD4-CUc : In : Imax:Up :

~385V20kA40kA1.8kV

Surge Protective Device

Outside Size Fig

MBD3 SeriesSurge Protective Device

Product introduction Model and Signification

MBD3- B series surge protective device

(hereinaf ter called SPD) is suitably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage. As per the conditions

of IEC61643-1:1998-02 standard, Cla ss I

surge protective device, it is category B

surge protective device.

SPD meets with GB18802.1/IEC61643-1

standards.

Installation

Category B surge protective device (SPD),

used in the connection between equal pot-

ential electrodes while thunder occur.

To be mounted: between LPZ0A or LPZ0B

zone and LPZ1 zone, adopts 35mm standard

mounting rail. The cross sectional area of

2multi-strand soft copper conductor: 2.5~35mm.

Generally to be installed in low voltage main

incoming distribution panel, overhead incoming.

As required, the user can assemble single pole

or three poles surge protective device freely.

Generally to be installed in low voltage main

incoming distribution panel, earthing wire

shall be dual color multi-strand soft copper

2conductor more than 16 mm

MB D 3 120 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Single pole structure, single pole or three

poles combined SPD available.

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal.

The visible window show white color in normal

service, if to be separated from network, it

will show red color. It can adopt Kelvin wiring

mode. Large current carrying capacity, fast

response time, low residual voltage.

Model and specification

Voltage protective level

<25

IP20

Maxi discharging current

Nominal discharging current

Response time

Application

Protection grade

Indication of invalidation

420

2.5

275

1.8

420

2.8

275

2.0

420

3.0

275

2.0

Protection for in line

Aging invalidation: white: Normal, red: invalidation

420

2.5

275

1.5

420

1.8

275

1.5

80 100 120654515

40 50 6030155

MBD3-80 MBD3-100 MBD3-120MBD3-65MBD3-40MBD3-15

420

1.2

275

1.0

Maxi continuous operating voltage

69

46

35

36

87

57

45

Uc: 385V

Imax:120kA(8/20)

In: 60kA(8/20)

Up : 3.0kV

Ref.8144-03-03

RecRec

Imax:40kA

Uc: 420V

In : 15kA

UP:1.8kV

MBD3-40

18

87

58 45

MBD3-40

Outside Size Fig

Product introduction Model and Signification

MBD4 series surge protective device

(hereinafter called SPD) is sui-tably used

in the IT, TT, TN-C, TN-S, TN-C-S and etc

power supply system of AC 50/60Hz, rated

voltage up to 380V, to protect from direct

and indirect lightning impulse and other

transient over voltage.

SPD meets with GB18802.1/IEC61643-1

standard.

MBD4 SeriesSurge Protective Device

Operation Elements

SPD as only one side of terminals, able to

prevent from being electric touching, indoor

fixedly mounted, limiting voltage.

SPD has built-in disconnector, when SPD

is invalid due to overheating or breakdown,

the disconnector can automatically separate

SPD from the network, meanwhile send an

indication signal. The visible window show

white color in normal service, if to be sepa-

rated from network, it will show red color.

Fast response time, low residual voltage.

To be mounted in joint of LPZ1 or LPZ2 zone,

adopts 35mm standard mounting rail. The

cross sectional area of multi-strand soft

2copper conductor: 2.5~ 35 mm .

Every pole of SPD shall be protected by fuse

or mini circuit breaker.

The Contact

SPD can provide the NO contact for remote

communication, if one or more modules of

SPD is invalid, the NO and NC contact will

be closed and send fault information.

MB D 4 40 385 - -

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Technical Parameter

Remarks

Remote signal Function

Application

Indication of invalidation

Protection grade

Response time

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operating voltage

Model and specification

Other maxi continuous working voltage Uc (AC) can be supplied if required.

<25

IP20

Protection for in line

Can also picking

Aging invalidation: white: Normal, red: invalidation

20

10

40

20

420

1.8

275

1.2

420

2.0

275

1.5

MBD4-20 MBD4-40

189 190

Page 15: Surge Protective Device -Meba

MBD5-120

Outside Size Fig

MBD6-40

MB D 6 40 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Accessories: X-the contact

Installation

MBD6-20 is mounted between LPZ1 or

LPZ2 zone and LPZ3 zone. The cross

sectional area of multi-strand soft copper

2conductor to be connecte d: 2.5~ 35 mm .

It is used in distribution boxes of living

house, computer center, communication

equipment, electronic equipment and

control equipment or nearest socket box.

MBD6-40 is mounted between LPZ0B or

LPZ1 zone and LPZ2 zone. The cross

sectional area of multi-strand soft copper

2conductor to be connected: 2.5~ 35 mm .

The Contact

Contact for remote communication can be

provided for SPD, the contact has one pair

for transferring, 11 as middle position, 12

and 11 opened under SPD acting, 14 and

11 closed under SPD acting, 11 and 14 as

NO contact . If one or more of modules of

SPD is invalid, the contact will be closed

and send fault signal.

Outside Size Fig

Technical Parameter

Model and specification

Voltage protective level

Response time

Protection grade

Application

Remote signal Function

Indication of invalidation

Remarks Other maxi continuous operating voltage Can be customized

Can also picking

Protection for in line

Aging invalidation: white: Normal, red: invalidation

IP20

<25

60

30

40

20

20

10Nominal discharging current

Maxi discharging current

Maxi continuous operating voltage

MBD6-60

420

2.5

385

2.0

MBD6-40 MBD6-20

320

1.8

275

1.6

420

2.0

385

1.8

320

1.6

275

1.3

420

1.8

385

1.5

320

1.3

275

1.2

MBD5 SeriesSurge Protective Device

Model and SignificationProduct introduction

MBD5 series surge protective device

(hereinafter called SPD) is suit-able for the

IT, TT, TN-C, TN-S, TN-C-S and etc power

supply system of AC 50/60Hz, rated voltage

380V and below, to protect from lightning

impulse and other transient over voltage,

it is applica ble in class I lightning proof

system where there has higher danger

of lightning strikes As per the conditions

of IEC61643-1:1998-02 standard, Class I

surge protective device, it is category B

surge protective device.

SPD meets with GB18802.1/IEC61643-1

standards.

Operation Elements

Fast response time: less than 25ns

Low limited voltage

Large current carrying capacity

Normal state: white color, invalid state:

red color

Kelvin wiring mode available.

Installation

Category B surge protective device (SPD),

used in the connection between equal

potential electrodes while thunder occur.

Generally to be installed in low voltage main

incoming distribution panel, overhead

incoming.

To adopt 35mm standard mounting rail for

SPD mounting.

When to place an order, please indicate the

model, specification and quantity of SPD. 2It shall adopt 10~35mm copper conductor

to be connected with SPD, earthing wire

shall be dual color multi-st rand s oft copper 2conductor more than 16mm .

The Contact

SPD can provide the NO contact for remote

communication, if one or more modules of

SPD is invalid, the NO and NC contact will

be closed and send fault information.

MB D 5 120 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Surge Protective Device

MBD5-120Uc~:

In(8/20):

Imax(8/20):

Up:

385V

60kA

120kA

2.5kV

36

90

RED:TO BE REPLACED

L(N)

35

65

Technical Parameter

<25

IP20

MBD5-100

50

Model and specification

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

Remarks

Can also picking

420

2.5

385

2.3

275

1.8

420

2.5

385

2.3

MBD5-120 MBD5-150

320

2.0

275

1.8

420

3.5

385

3.2

320

2.5

275

2

60

100 120 150

80

Primary protection for in line

Other maxi continuous operating voltage Can be customizedUc175,440,690V

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operat ing voltage

Aging invalidation: white: Normal, red: invalidation

MBD6 SeriesSurge Protective Device

Model and SignificationProduct introduction

MBD6 series surge protective device

(hereinafter called SPD) is suitably used

in the TT TN-S TN-C IT TN-C-S and

etc power supply system of AC 50/60Hz,

rated voltage 380V and below, to protect

from direct and indirect lightning impulse

and other transient over voltage.

SPD meets with GB18802.1/IEC61643-1

standard.

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

N L L L

18

72

90

45

63

49

35

Surge Protective Device

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

Surge Protective Device

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

Surge Protective Device

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

Surge Protective Device

191 192

Page 16: Surge Protective Device -Meba

MBD5-120

Outside Size Fig

MBD6-40

MB D 6 40 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Accessories: X-the contact

Installation

MBD6-20 is mounted between LPZ1 or

LPZ2 zone and LPZ3 zone. The cross

sectional area of multi-strand soft copper

2conductor to be connecte d: 2.5~ 35 mm .

It is used in distribution boxes of living

house, computer center, communication

equipment, electronic equipment and

control equipment or nearest socket box.

MBD6-40 is mounted between LPZ0B or

LPZ1 zone and LPZ2 zone. The cross

sectional area of multi-strand soft copper

2conductor to be connected: 2.5~ 35 mm .

The Contact

Contact for remote communication can be

provided for SPD, the contact has one pair

for transferring, 11 as middle position, 12

and 11 opened under SPD acting, 14 and

11 closed under SPD acting, 11 and 14 as

NO contact . If one or more of modules of

SPD is invalid, the contact will be closed

and send fault signal.

Outside Size Fig

Technical Parameter

Model and specification

Voltage protective level

Response time

Protection grade

Application

Remote signal Function

Indication of invalidation

Remarks Other maxi continuous operating voltage Can be customized

Can also picking

Protection for in line

Aging invalidation: white: Normal, red: invalidation

IP20

<25

60

30

40

20

20

10Nominal discharging current

Maxi discharging current

Maxi continuous operating voltage

MBD6-60

420

2.5

385

2.0

MBD6-40 MBD6-20

320

1.8

275

1.6

420

2.0

385

1.8

320

1.6

275

1.3

420

1.8

385

1.5

320

1.3

275

1.2

MBD5 SeriesSurge Protective Device

Model and SignificationProduct introduction

MBD5 series surge protective device

(hereinafter called SPD) is suit-able for the

IT, TT, TN-C, TN-S, TN-C-S and etc power

supply system of AC 50/60Hz, rated voltage

380V and below, to protect from lightning

impulse and other transient over voltage,

it is applica ble in class I lightning proof

system where there has higher danger

of lightning strikes As per the conditions

of IEC61643-1:1998-02 standard, Class I

surge protective device, it is category B

surge protective device.

SPD meets with GB18802.1/IEC61643-1

standards.

Operation Elements

Fast response time: less than 25ns

Low limited voltage

Large current carrying capacity

Normal state: white color, invalid state:

red color

Kelvin wiring mode available.

Installation

Category B surge protective device (SPD),

used in the connection between equal

potential electrodes while thunder occur.

Generally to be installed in low voltage main

incoming distribution panel, overhead

incoming.

To adopt 35mm standard mounting rail for

SPD mounting.

When to place an order, please indicate the

model, specification and quantity of SPD. 2It shall adopt 10~35mm copper conductor

to be connected with SPD, earthing wire

shall be dual color multi-st rand s oft copper 2conductor more than 16mm .

The Contact

SPD can provide the NO contact for remote

communication, if one or more modules of

SPD is invalid, the NO and NC contact will

be closed and send fault information.

MB D 5 120 385 - - -

Number of poles: 1P, 2P, 3P, 4P

Maxi continuous operating voltage Uc(V)

Maxi discharging current Imax(8/20 s)(kA)

Design No

Surge Protective Device(SPD)

Enterprise code

Surge Protective Device

MBD5-120Uc~:

In(8/20):

Imax(8/20):

Up:

385V

60kA

120kA

2.5kV

36

90

RED:TO BE REPLACED

L(N)

35

65

Technical Parameter

<25

IP20

MBD5-100

50

Model and specification

Response time

Application

Protection grade

Remote signal Function

Indication of invalidation

Remarks

Can also picking

420

2.5

385

2.3

275

1.8

420

2.5

385

2.3

MBD5-120 MBD5-150

320

2.0

275

1.8

420

3.5

385

3.2

320

2.5

275

2

60

100 120 150

80

Primary protection for in line

Other maxi continuous operating voltage Can be customizedUc175,440,690V

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operat ing voltage

Aging invalidation: white: Normal, red: invalidation

MBD6 SeriesSurge Protective Device

Model and SignificationProduct introduction

MBD6 series surge protective device

(hereinafter called SPD) is suitably used

in the TT TN-S TN-C IT TN-C-S and

etc power supply system of AC 50/60Hz,

rated voltage 380V and below, to protect

from direct and indirect lightning impulse

and other transient over voltage.

SPD meets with GB18802.1/IEC61643-1

standard.

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

N L L L

18

72

90

45

63

49

35

Surge Protective Device

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

Surge Protective Device

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

Surge Protective Device

MBD6-CUc : ~385VIn : 20kAImax: 40kAUp : 1.8kV

Surge Protective Device

191 192

Page 17: Surge Protective Device -Meba

MBX-R/L24

MBX-R/L SeriesSurge Protective Device

MBX-R/ L surge pr otect or prot ect un-earthed dat a (asymmetrica l, suspended) cable that used for dual wire electronic measurement

and control and the voltage shall not exceed 110V, frequency not more than 2MHz, to prevent data cabl e and relate d equipment from

being damaged due to surging over-voltage caused by lightning or traveling wave. It is mounted between LPZ1 LPZ3.

MBX-R/L two-stage circuit consists of gas discharging tube, piezore-sistance and clamping diode, with advantages of large

discharging capacity, short clamping time and low protection level.

MBX-R/L protector can be mounted on 35mm rail of different sta ndard switching box or distribution box. It does not need screws for

connecting with terminal.

Function and application

62

50

35

18

91

45

IN

OUT

1 PE 2

4 PE 3

MBX-L24

:

:

:

:

:

24V

27V

200mA

5kA

80V

UN

Uc

IL

In(8/20)

Up

Technical ParameterOutside Size Fig

MBX-R/L

1 3

5V

7V

13V

6V

9V

20V

12V

15V

30V

24V

30V

51V

48V

51V

100V

0.2A

1.0A

Arrester

10KA

Mounting position

100 H

15

Nominal voltage

Max. continuous operating voltage

Voltage protective level

Rated loading current of category R

Rated loading current of category L

Nominal discharging current

Series connected resistance of each line of category R

Series connected inductance of each line of category L

Cross sectional area of connected conductor

Peel-off length for the wire to be connected

Color

20.14-2.5mm

6-7mm

Grey

Material Fire resistant reinforced PC

Applicable standard GB18802.2 IEC61643-21

MBX-N

MBX-N SeriesSurge Protective Device

Product introduction Model Signification

MB X - N /

SPD used in signal control line of data transmission.

Network Surge Protector

Enterprise code

Protection Port 8 16 24

Technical Parameter

MBX-N 12V 5KA(8/20) <35V <0.2VdB 10ns RJ45

Model and specification

Rated voltage

Protective level

Insertion loss

Response time

Interfacemode

Flux

Installation

This surge protect ive device will be series connected between circuit and protected

equipment, outp ut terminal of SPD shall be connected with input of equipment to be

protected, the circuit distance connected shall be short as possible, this can get best

protection effect.

The PE line shall be reliably connected with earthing line of lightning system, this

leading wire shall be shortest as possible, to get good protection effect.

If this SPD discharged the surging many times and take on invalidation, please replace

it on time, to ensure continuous safety.

This product belong to termination protection device, due to uncertainty of lightning

and surging, it shall cooperate well with anterior protection appliance in consideration

of working conditions, in order to get good protection effect .

Lightning injury mainly is by the way of

the line of power supply or signal circuits

for connected equipment. Cons equen tly

it is necessary that it shall protect power

line or circuits effective ly from being

damaged or personnel injury.

MBX-N series surge protective device,

adopts international latest gas discharging

tube, TVS tub e, solid discharging tube of

quicker response, good non-linear curve,

large flux, as the protective elements,

assembled with auxiliary components,

via optimized production technology.

Which lessen the output residual voltage.

When equipment happen to over-volt age,

this SPD quickly respond leading over-

current discharged into ground, limiting

the line voltage within permissible value,

and finally to protect personnel safety

and equipment from being damaged.

The product meets with IEC61643-1 and

related standards.

Product purpose

Surging protection for computer, network

station, data exchanging network can avoid

the damage due to inductive voltage and

surging voltage coming from signal circuit.

193 194

Page 18: Surge Protective Device -Meba

MBX-R/L24

MBX-R/L SeriesSurge Protective Device

MBX-R/ L surge pr otect or prot ect un-earthed dat a (asymmetrica l, suspended) cable that used for dual wire electronic measurement

and control and the voltage shall not exceed 110V, frequency not more than 2MHz, to prevent data cabl e and relate d equipment from

being damaged due to surging over-voltage caused by lightning or traveling wave. It is mounted between LPZ1 LPZ3.

MBX-R/L two-stage circuit consists of gas discharging tube, piezore-sistance and clamping diode, with advantages of large

discharging capacity, short clamping time and low protection level.

MBX-R/L protector can be mounted on 35mm rail of different sta ndard switching box or distribution box. It does not need screws for

connecting with terminal.

Function and application

62

50

35

18

91

45

IN

OUT

1 PE 2

4 PE 3

MBX-L24

:

:

:

:

:

24V

27V

200mA

5kA

80V

UN

Uc

IL

In(8/20)

Up

Technical ParameterOutside Size Fig

MBX-R/L

1 3

5V

7V

13V

6V

9V

20V

12V

15V

30V

24V

30V

51V

48V

51V

100V

0.2A

1.0A

Arrester

10KA

Mounting position

100 H

15

Nominal voltage

Max. continuous operating voltage

Voltage protective level

Rated loading current of category R

Rated loading current of category L

Nominal discharging current

Series connected resistance of each line of category R

Series connected inductance of each line of category L

Cross sectional area of connected conductor

Peel-off length for the wire to be connected

Color

20.14-2.5mm

6-7mm

Grey

Material Fire resistant reinforced PC

Applicable standard GB18802.2 IEC61643-21

MBX-N

MBX-N SeriesSurge Protective Device

Product introduction Model Signification

MB X - N /

SPD used in signal control line of data transmission.

Network Surge Protector

Enterprise code

Protection Port 8 16 24

Technical Parameter

MBX-N 12V 5KA(8/20) <35V <0.2VdB 10ns RJ45

Model and specification

Rated voltage

Protective level

Insertion loss

Response time

Interfacemode

Flux

Installation

This surge protect ive device will be series connected between circuit and protected

equipment, outp ut terminal of SPD shall be connected with input of equipment to be

protected, the circuit distance connected shall be short as possible, this can get best

protection effect.

The PE line shall be reliably connected with earthing line of lightning system, this

leading wire shall be shortest as possible, to get good protection effect.

If this SPD discharged the surging many times and take on invalidation, please replace

it on time, to ensure continuous safety.

This product belong to termination protection device, due to uncertainty of lightning

and surging, it shall cooperate well with anterior protection appliance in consideration

of working conditions, in order to get good protection effect .

Lightning injury mainly is by the way of

the line of power supply or signal circuits

for connected equipment. Cons equen tly

it is necessary that it shall protect power

line or circuits effective ly from being

damaged or personnel injury.

MBX-N series surge protective device,

adopts international latest gas discharging

tube, TVS tub e, solid discharging tube of

quicker response, good non-linear curve,

large flux, as the protective elements,

assembled with auxiliary components,

via optimized production technology.

Which lessen the output residual voltage.

When equipment happen to over-volt age,

this SPD quickly respond leading over-

current discharged into ground, limiting

the line voltage within permissible value,

and finally to protect personnel safety

and equipment from being damaged.

The product meets with IEC61643-1 and

related standards.

Product purpose

Surging protection for computer, network

station, data exchanging network can avoid

the damage due to inductive voltage and

surging voltage coming from signal circuit.

193 194

Page 19: Surge Protective Device -Meba

MBX-DB9/25MBX-Z

Product introduction Product introduction

Computer network lightning protector is mainly used to prevent

lightning (overvoltage) from access to equipment via network

circuits, widely serving for the network equipments in banking

system, communication system, traf fic and t ransportation system,

petrochemical control system and etc.

Characteristics

High surge current passing by; multi-step protected.

Built-in fast semi-conductive protective element, quick response

speed and lower residual voltage.

Low inserting loss, ensure circuit working safely.

Core element adopted international famous products, with

excellent performances.

It is to be easy installed, suitable for different standard ports.

MBX1-RJ11/45

Operation instruction

This product is of series connected mode.

Please choose the right protector with same port of the equipment

to be protected.

In the protector, "IN" is input terminal, "OUT" is output terminal,

input terminal connected with exterior wires, output terminal

connected to input side of the equipment to be protected.

PE line of protector must be connected solidl y to earthing wire

of lightning proof system, connected wire shall be short, large

and straight.

During servicing, the protector shall be inspected periodically,

if some fault happen, it shall be repaired or replace on time.

Earthing resistance not larger than 4Ù.

Laypeople do not remove.

Monitoring Comprehensive Surge Protector

MBX-Z Series

Model Signification

220 2MB X - Z /

SPD used in signal control line of data transmission.

Enterprise code

Two in One, Three in One

Power supply voltage

Monitoring comprehensive surge protector

MBX-Z series surge protective device for AC/DC supply

monitoring vidicon is multifunction integrated protector (3 in 1),

can protect the circuit of power supply, video and audio, Pan-

tilt control in vidicon from surging, maximum discharging current

up to 1000A, to limit voltage down to 15V, response time: picosecond

class. It can fully protect the latest hi-tech monitoring equipments.

Multifunctional surging over-voltage protection-12Large capacity: 1000A Quick response: (10 s)

3 in 1 designed. Low loss

Technical Parameter

Model and specification

Functions

Nominal discharging current

Maxi continuous operating voltage

Load current

Limiting voltage

Maxi discharging current

Maxi continuous operating voltage

Limiting voltage

Nominal discharging current

Maxi discharging current

Max. Transmission rates

Maxi continuous operating voltage

Limiting voltage

Nominal discharging current

MBX-Z

Comprehensive surge protector

Power protection parameters

8V

15V

5kA

PTZ control signal protective parameter (only Three in One type)

10MHz(Insertion loss<0.2dB)

320V

10A

900V

5kA

10kA

40V

5A

75V

5kA

10kA

8V

15V

5kA

10kA

Video protection parameters

MBX-DB9/25 SeriesPort Surge Protector

IN

OU

T

79(105)

25

25

25

40

RJ45 RJ11

Outside Size Fig

MBX1-RJ11/45 SeriesSurge Protective Device

Model and SignificationProduct introduction

MBX1-RJ11 series signal surge protectiv e

device (hereinafter called SPD) is suitable

for the circuit of Modem, DDN special line,

facsimile, telephone and etc, to protect

communication equipment from being

damaged by lightning impulse and other

transient over voltage.

MBX1-RJ45 series signal surge protect ive

device (hereinafter called SPD) is suitable

for the circuit of Ethernet, local area network

(LAN), Token ring, server, routers, Hub, broad

band, the functions of rough prote ction,

fine protection, precise protection can meet

with differen t requirements for protection

zone against surging, to protect RJ45

inter face and communication equipment

from being damaged due potential rise up

or ove r-vol tage result from circuit induction.

Installation

To be mounted in the interface between

LPZ1 to LPZ3.

To be mounted in the interf ace of RJ11,

as required, it can form multiple poles or

multi circuit lightning proof device, in the

joint of PZ2, connected with multi-st rand

2soft copper conductor of 2.5~35mm .

Operation Elements

MBX1-RJ11: Small cross sectional area,

low inductive voltage drop, dual protection

against over-voltage and overloading,

outer shell is made of shielded Al.

MBX1-RJ45: Input and output by RJ45

male/ female connector, easy to be connected

and assembled, small cross sectional area,

low inductive voltage drop, dual protection

against over-voltage and overloading,

outer shell is made of shielded Al.

Working vol tage: 5-DC5V, 12-DC12V, 24-DC24V, 48-DC48V, 110-DC110V

Frequency bandwidth: C-2MHz, D-10MHz, F-100MHz

Interface mode: (RJ11/RJ45)

Design No

SPD used in signal control line of data transmission.

Enterprise code

MB X - / 1

Technical Parameter

Model and specification

Network service voltage

Maxi continuous operating voltage

Voltage protective level

Attackdischarging current

Nominal discharging current

Frequency bandwidth

Insertion loss

Protective circuit

Response time

Invalid factor

MBX1-RJ11

AC110

DC110

DC150

500

2MHz

0.5db

3, 4

Communication circuit Short connectedwith ground, or communication circuit opened.

1

100MHz

0.3db

1, 2, 3, 6

600

3

DC5

DC6

40

DC12

DC15

60

MBX1-RJ45

DD5 ED5 DD12 ED12

195 196

Page 20: Surge Protective Device -Meba

MBX-DB9/25MBX-Z

Product introduction Product introduction

Computer network lightning protector is mainly used to prevent

lightning (overvoltage) from access to equipment via network

circuits, widely serving for the network equipments in banking

system, communication system, traf fic and t ransportation system,

petrochemical control system and etc.

Characteristics

High surge current passing by; multi-step protected.

Built-in fast semi-conductive protective element, quick response

speed and lower residual voltage.

Low inserting loss, ensure circuit working safely.

Core element adopted international famous products, with

excellent performances.

It is to be easy installed, suitable for different standard ports.

MBX1-RJ11/45

Operation instruction

This product is of series connected mode.

Please choose the right protector with same port of the equipment

to be protected.

In the protector, "IN" is input terminal, "OUT" is output terminal,

input terminal connected with exterior wires, output terminal

connected to input side of the equipment to be protected.

PE line of protector must be connected solidl y to earthing wire

of lightning proof system, connected wire shall be short, large

and straight.

During servicing, the protector shall be inspected periodically,

if some fault happen, it shall be repaired or replace on time.

Earthing resistance not larger than 4Ù.

Laypeople do not remove.

Monitoring Comprehensive Surge Protector

MBX-Z Series

Model Signification

220 2MB X - Z /

SPD used in signal control line of data transmission.

Enterprise code

Two in One, Three in One

Power supply voltage

Monitoring comprehensive surge protector

MBX-Z series surge protective device for AC/DC supply

monitoring vidicon is multifunction integrated protector (3 in 1),

can protect the circuit of power supply, video and audio, Pan-

tilt control in vidicon from surging, maximum discharging current

up to 1000A, to limit voltage down to 15V, response time: picosecond

class. It can fully protect the latest hi-tech monitoring equipments.

Multifunctional surging over-voltage protection-12Large capacity: 1000A Quick response: (10 s)

3 in 1 designed. Low loss

Technical Parameter

Model and specification

Functions

Nominal discharging current

Maxi continuous operating voltage

Load current

Limiting voltage

Maxi discharging current

Maxi continuous operating voltage

Limiting voltage

Nominal discharging current

Maxi discharging current

Max. Transmission rates

Maxi continuous operating voltage

Limiting voltage

Nominal discharging current

MBX-Z

Comprehensive surge protector

Power protection parameters

8V

15V

5kA

PTZ control signal protective parameter (only Three in One type)

10MHz(Insertion loss<0.2dB)

320V

10A

900V

5kA

10kA

40V

5A

75V

5kA

10kA

8V

15V

5kA

10kA

Video protection parameters

MBX-DB9/25 SeriesPort Surge Protector

IN

OU

T

79(105)

25

25

25

40

RJ45 RJ11

Outside Size Fig

MBX1-RJ11/45 SeriesSurge Protective Device

Model and SignificationProduct introduction

MBX1-RJ11 series signal surge protectiv e

device (hereinafter called SPD) is suitable

for the circuit of Modem, DDN special line,

facsimile, telephone and etc, to protect

communication equipment from being

damaged by lightning impulse and other

transient over voltage.

MBX1-RJ45 series signal surge protect ive

device (hereinafter called SPD) is suitable

for the circuit of Ethernet, local area network

(LAN), Token ring, server, routers, Hub, broad

band, the functions of rough prote ction,

fine protection, precise protection can meet

with differen t requirements for protection

zone against surging, to protect RJ45

inter face and communication equipment

from being damaged due potential rise up

or ove r-vol tage result from circuit induction.

Installation

To be mounted in the interface between

LPZ1 to LPZ3.

To be mounted in the interf ace of RJ11,

as required, it can form multiple poles or

multi circuit lightning proof device, in the

joint of PZ2, connected with multi-st rand

2soft copper conductor of 2.5~35mm .

Operation Elements

MBX1-RJ11: Small cross sectional area,

low inductive voltage drop, dual protection

against over-voltage and overloading,

outer shell is made of shielded Al.

MBX1-RJ45: Input and output by RJ45

male/ female connector, easy to be connected

and assembled, small cross sectional area,

low inductive voltage drop, dual protection

against over-voltage and overloading,

outer shell is made of shielded Al.

Working vol tage: 5-DC5V, 12-DC12V, 24-DC24V, 48-DC48V, 110-DC110V

Frequency bandwidth: C-2MHz, D-10MHz, F-100MHz

Interface mode: (RJ11/RJ45)

Design No

SPD used in signal control line of data transmission.

Enterprise code

MB X - / 1

Technical Parameter

Model and specification

Network service voltage

Maxi continuous operating voltage

Voltage protective level

Attackdischarging current

Nominal discharging current

Frequency bandwidth

Insertion loss

Protective circuit

Response time

Invalid factor

MBX1-RJ11

AC110

DC110

DC150

500

2MHz

0.5db

3, 4

Communication circuit Short connectedwith ground, or communication circuit opened.

1

100MHz

0.3db

1, 2, 3, 6

600

3

DC5

DC6

40

DC12

DC15

60

MBX1-RJ45

DD5 ED5 DD12 ED12

195 196

Page 21: Surge Protective Device -Meba

MBD-W MBD-T MB380-20

MBD-W SeriesSurge Protective Device

Product introduction

MBD-W series wireless signal surge protectiv e device, designed

according to IEC standard, divi ded into interna tional F10 head,

ANSI F10 head, BNC hea d, N mode, L16, SL16, TNC and etc

coaxial interface, suitable for satellite ground station of satellite,

wireless communication equipment as GSM, CDMA, microwave

station and etc system and wireless broad network and etc coaxial

communication equipment, it can protect electronic communication

equipment from being damaged by over voltage due to lightning

strike, inductive over-voltage, and static discharging.

Protection against surging over-voltage in communication circuit.

Multiple interfaces for choice, easy to be installed.

Good hi-freq characteristics.

Low voltage standing wave rate.

Large carrying capacity.

Micro insertion and cast loss.

Technical Parameter

MBD-W

1.2

300W

0.1dB

BNC/N/TNC/SL16/L16

DC30V/DC68V/AC130V/AC280V

10kA

50/75

Model and specification

Interface mode

Maxi continuous operating voltage

Nominal discharging current

Characteristic impedance

Power

Insertion loss

Standing wave rate

24V

30V

10kA

50/75

0.1dB

120V

Communication circuit short connected with ground

Outer shell earthed

MBD-T SeriesSurge Protective Device

Product introduction

MBD-T series coaxial communication signal surge protective

device, designed according to IEC standard, divided into F10

head, N head, BNC head and etc co axial interface, suitable for

CATV, monitoring, Video communication equipment. It can

provide the protection for cablet and thicknet equipment.

Protection against surging over-voltage in communication circuit.

Wide bandwidth, low insertion loss.

N/F/BUG bidirectional interface.

Free of maintenance.

Fast response.

Technical Parameter

MBD-TModel and specification

Interface mode

Maxi continuous operating voltage

Nominal discharging current

Characteristic impedance

Insertion loss

N/F/BINC/TNC

Working voltage

Limiting voltage

Invalid factor

Remarks

Product introduction Technical Parameter

MB SeriesBox Surge Protective Device

MB series lightning proof box is designed

according to IEC and national standards,

it has the indicators of invalidation of lightning

proof function, earthing invalidation, the

circuit auto-breaking protection device

against the invalidation of lightning proof

function, the key part of lightning proof

box is high efficient lightning proof module,

each line of discha-rging capacity is 20KA

to 80KA, voltage prote-ction level at nominal

discharging current less than 2.5KV, response

time of lightning dis-charging less than

25ns, it can effect ively eliminate the surging

over- volta ge and protect the electronic

equipment.

MB series lightning proof box has excellent

lightning proof effects, used in single/three

phase power source system, where the

equipment need high lightning proof function.

MB series lightning proof box is wall hung

mounted, generally used for the distribut ion

panel without mounting space.

1. High lightning impulse discharging.

2. Circuit auto breaking protection against

the invalidation of lightning proof function.

3. Lamp indicator for the invalidation of

lightning proof function.

4. Discharging time very short, nanosecond

class.

5. Lamp indicator for earthing invalidation.

6. Low voltage protective level.

7. Counter for lightning strikes (optional).

8. Single or three phases for choice.

MB380-20 MB380-40 MB380-60 MB380-80Model and specification

SPD interface classifications

SPD kinds

Maxi discharging current

Limiting voltage

Protection mode

Maxi continuous operating voltage

Conductor to be connected

Indication for invalidation, Green as Normal state, Red as Invalidation

Working temperature

Protection grade of shell

Product size (L x W x H)

Single interface

Limiting voltage type

L-N-PE

385V

210-16mm

LED alarm

-40/85

Ip50

235*165*70

<1500V <1800V <2000V <2500V

>20KA/ Each line >40KA/ Each line >60KA/ Each line >80KA/ Each line

Outside Size Fig

165mm

118mm

21

0m

m

23

5m

m

67.5mm

118mm

197 198

Page 22: Surge Protective Device -Meba

MBD-W MBD-T MB380-20

MBD-W SeriesSurge Protective Device

Product introduction

MBD-W series wireless signal surge protectiv e device, designed

according to IEC standard, divi ded into interna tional F10 head,

ANSI F10 head, BNC hea d, N mode, L16, SL16, TNC and etc

coaxial interface, suitable for satellite ground station of satellite,

wireless communication equipment as GSM, CDMA, microwave

station and etc system and wireless broad network and etc coaxial

communication equipment, it can protect electronic communication

equipment from being damaged by over voltage due to lightning

strike, inductive over-voltage, and static discharging.

Protection against surging over-voltage in communication circuit.

Multiple interfaces for choice, easy to be installed.

Good hi-freq characteristics.

Low voltage standing wave rate.

Large carrying capacity.

Micro insertion and cast loss.

Technical Parameter

MBD-W

1.2

300W

0.1dB

BNC/N/TNC/SL16/L16

DC30V/DC68V/AC130V/AC280V

10kA

50/75

Model and specification

Interface mode

Maxi continuous operating voltage

Nominal discharging current

Characteristic impedance

Power

Insertion loss

Standing wave rate

24V

30V

10kA

50/75

0.1dB

120V

Communication circuit short connected with ground

Outer shell earthed

MBD-T SeriesSurge Protective Device

Product introduction

MBD-T series coaxial communication signal surge protective

device, designed according to IEC standard, divided into F10

head, N head, BNC head and etc co axial interface, suitable for

CATV, monitoring, Video communication equipment. It can

provide the protection for cablet and thicknet equipment.

Protection against surging over-voltage in communication circuit.

Wide bandwidth, low insertion loss.

N/F/BUG bidirectional interface.

Free of maintenance.

Fast response.

Technical Parameter

MBD-TModel and specification

Interface mode

Maxi continuous operating voltage

Nominal discharging current

Characteristic impedance

Insertion loss

N/F/BINC/TNC

Working voltage

Limiting voltage

Invalid factor

Remarks

Product introduction Technical Parameter

MB SeriesBox Surge Protective Device

MB series lightning proof box is designed

according to IEC and national standards,

it has the indicators of invalidation of lightning

proof function, earthing invalidation, the

circuit auto-breaking protection device

against the invalidation of lightning proof

function, the key part of lightning proof

box is high efficient lightning proof module,

each line of discha-rging capacity is 20KA

to 80KA, voltage prote-ction level at nominal

discharging current less than 2.5KV, response

time of lightning dis-charging less than

25ns, it can effect ively eliminate the surging

over- volta ge and protect the electronic

equipment.

MB series lightning proof box has excellent

lightning proof effects, used in single/three

phase power source system, where the

equipment need high lightning proof function.

MB series lightning proof box is wall hung

mounted, generally used for the distribut ion

panel without mounting space.

1. High lightning impulse discharging.

2. Circuit auto breaking protection against

the invalidation of lightning proof function.

3. Lamp indicator for the invalidation of

lightning proof function.

4. Discharging time very short, nanosecond

class.

5. Lamp indicator for earthing invalidation.

6. Low voltage protective level.

7. Counter for lightning strikes (optional).

8. Single or three phases for choice.

MB380-20 MB380-40 MB380-60 MB380-80Model and specification

SPD interface classifications

SPD kinds

Maxi discharging current

Limiting voltage

Protection mode

Maxi continuous operating voltage

Conductor to be connected

Indication for invalidation, Green as Normal state, Red as Invalidation

Working temperature

Protection grade of shell

Product size (L x W x H)

Single interface

Limiting voltage type

L-N-PE

385V

210-16mm

LED alarm

-40/85

Ip50

235*165*70

<1500V <1800V <2000V <2500V

>20KA/ Each line >40KA/ Each line >60KA/ Each line >80KA/ Each line

Outside Size Fig

165mm

118mm

21

0m

m

23

5m

m

67.5mm

118mm

197 198

Page 23: Surge Protective Device -Meba

MBD-S MBD-C

MBD-S SeriesExplosion Proof Surge Protected Power Source Box

Product introduction

Classification

Classif ied according to system: Single

phase, three-phase four-wire, according

to applicable site: B type, luxury type.

Power supply incoming distribut ion box,

downside main auto switch (fuse).

C The distribution box that the length of

wire connected to user incoming power

supply distribution box is more than 15m,

downside main auto switch (fuse).

D Downside main auto switch (fuse) of

terminal box.

Classified according to voltage limiting

level: 1-2kV, 2-1.5kV, 3-1kV.

Classified according to connection mode:

shunt connection, series connection (2-

step, 3-step).

Classified according to accessory: A, B, C

Operation Elements

The SPD in lightning proof box has the

ind-ication device for invalidation, Green

mean normal service, Red means SPD

invalidation.

The breaker (fuse) in lightningproof box

will assure the SPD being separated from

net-work if PSD is invalid.

Alarm is the extra necessary device for

sho-wing the invalid SPD. It can produce

sound and optica l signals when SPD is

invalid, if the fault can't be eliminated in

time, it can push"STOP"button to terminate

annunciator sounding. But red indicator

still shows the fault state (shining). If the

fault is not swept away after 24 hours, the

annunciator will sound again. User can

choose such device as required.

MBD-S series power supply lightning

proof device (hereinafter called SPD box)

is suitable for AC 50/60Hz, rated voltage

380V power supply system, to protect from

direct or indirect lightning impulse or other

transient over voltage.

SPD box meets wi th GB18802.1, IEC61643-

1 and YD/T1235.1 standards.

Model and Signification

MB D - S - -

Lightningproof modules 1,2,3,4,

Lightningproof box

Surge protective device

Enterprise code

Maximum continuous operating voltage

Accessories: A: N/A, B: Sound and optical annunciator, C: Fuse, D: Sound & optical annunciator and fuse.

Loading capacity: as per main technical specifications.

Voltage limiting level: 1-2kV, 2-1.5kV, 3-1kV

Mounting category: A: User incoming power supply distribution box, downside main breaker (or fuse).B: The distribution box that the length of wire connected to user incoming power supply distri-bution box is more than 15m, downside main auto switch (fuse).C: Downside main auto switch (fuse) of terminal box.

Electric connection: 0-shunt connection, 2-2 step series connection, 3- three-step series connection

Technical Parameter

Model and specification MBD-S-100

380/220

385

2.02.5 1.8

MBD-S-60 MBD-S-40

60100 40

Network service voltage

Maxi continuous operating voltage

IP20

25

Voltage protective level

Maxi discharging current

Counting for lightning strikes

Response time

Protection grade

Application

Lowest counting current: 1KA, maxi 99 times.

Primary protection for power supplySecondary protection for power supply

Product introduction

MBD-C SeriesMuiti-functional PowerStrip With Surge Protection

MBD-C series receptacle type surge

protective device (hereina fter called SPD)

is suitably used in the power supply system

of AC 50/60Hz, rated voltage up to 220V,

as the secondary protective device for

equipment, to protect from direct and

indirect lightning impulse and other transient

over voltage, and absorb wireless/radio

interference and etc circuit surging, extend

the working life of equipment, save the

long-term operating cost.

SPD meets with GB18802.1, IEC61643-

1-1 standards.

Operation Elements

Receptacle type SPD cooperated with

socket, Built -in over-current protecti on unit,

prevent fire danger caused by accident.

Rear bu tterfl y hole, it can be mounted

on desk or wall.

Wrong ea rthi ng wire, indication of inverse

insertion, assure reliable earthing, avoid

incidental electric leakage.

Wrong e arthing wire, indicat ion of inverse

inser tion, prevent inverse insertion

between phase and earthing lines.

Shor t circuit indication, dual color indication

for different states, red and green color.

Outer shell material: reinforced fire resistant.

PBT, in compliance wit h UL94-5V standard.

MB D C - 4 2- -

Surge protective device

Enterprise code

International 2 Pin number

International 3 Pin number

Lightningproof socket

Model and Signification

Indicate when placing an order

Please indicate the model, specification and quantity of SPD.

The following documents and accessories will be delivered together with goods.

Certificate of qualification 1 copy (each product) Operation manual 1 copy

(each product)

Technical Parameter

Protection grade

Response time

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operating voltage

Power source for network service

suitable for power supply systems

Model and specification MBD-C

TT/TN/IT

220V

330V

1kV

10kA

5kA

25ns

IP20

199 200

Page 24: Surge Protective Device -Meba

MBD-S MBD-C

MBD-S SeriesExplosion Proof Surge Protected Power Source Box

Product introduction

Classification

Classif ied according to system: Single

phase, three-phase four-wire, according

to applicable site: B type, luxury type.

Power supply incoming distribut ion box,

downside main auto switch (fuse).

C The distribution box that the length of

wire connected to user incoming power

supply distribution box is more than 15m,

downside main auto switch (fuse).

D Downside main auto switch (fuse) of

terminal box.

Classified according to voltage limiting

level: 1-2kV, 2-1.5kV, 3-1kV.

Classified according to connection mode:

shunt connection, series connection (2-

step, 3-step).

Classified according to accessory: A, B, C

Operation Elements

The SPD in lightning proof box has the

ind-ication device for invalidation, Green

mean normal service, Red means SPD

invalidation.

The breaker (fuse) in lightningproof box

will assure the SPD being separated from

net-work if PSD is invalid.

Alarm is the extra necessary device for

sho-wing the invalid SPD. It can produce

sound and optica l signals when SPD is

invalid, if the fault can't be eliminated in

time, it can push"STOP"button to terminate

annunciator sounding. But red indicator

still shows the fault state (shining). If the

fault is not swept away after 24 hours, the

annunciator will sound again. User can

choose such device as required.

MBD-S series power supply lightning

proof device (hereinafter called SPD box)

is suitable for AC 50/60Hz, rated voltage

380V power supply system, to protect from

direct or indirect lightning impulse or other

transient over voltage.

SPD box meets wi th GB18802.1, IEC61643-

1 and YD/T1235.1 standards.

Model and Signification

MB D - S - -

Lightningproof modules 1,2,3,4,

Lightningproof box

Surge protective device

Enterprise code

Maximum continuous operating voltage

Accessories: A: N/A, B: Sound and optical annunciator, C: Fuse, D: Sound & optical annunciator and fuse.

Loading capacity: as per main technical specifications.

Voltage limiting level: 1-2kV, 2-1.5kV, 3-1kV

Mounting category: A: User incoming power supply distribution box, downside main breaker (or fuse).B: The distribution box that the length of wire connected to user incoming power supply distri-bution box is more than 15m, downside main auto switch (fuse).C: Downside main auto switch (fuse) of terminal box.

Electric connection: 0-shunt connection, 2-2 step series connection, 3- three-step series connection

Technical Parameter

Model and specification MBD-S-100

380/220

385

2.02.5 1.8

MBD-S-60 MBD-S-40

60100 40

Network service voltage

Maxi continuous operating voltage

IP20

25

Voltage protective level

Maxi discharging current

Counting for lightning strikes

Response time

Protection grade

Application

Lowest counting current: 1KA, maxi 99 times.

Primary protection for power supplySecondary protection for power supply

Product introduction

MBD-C SeriesMuiti-functional PowerStrip With Surge Protection

MBD-C series receptacle type surge

protective device (hereina fter called SPD)

is suitably used in the power supply system

of AC 50/60Hz, rated voltage up to 220V,

as the secondary protective device for

equipment, to protect from direct and

indirect lightning impulse and other transient

over voltage, and absorb wireless/radio

interference and etc circuit surging, extend

the working life of equipment, save the

long-term operating cost.

SPD meets with GB18802.1, IEC61643-

1-1 standards.

Operation Elements

Receptacle type SPD cooperated with

socket, Built -in over-current protecti on unit,

prevent fire danger caused by accident.

Rear bu tterfl y hole, it can be mounted

on desk or wall.

Wrong ea rthi ng wire, indication of inverse

insertion, assure reliable earthing, avoid

incidental electric leakage.

Wrong e arthing wire, indicat ion of inverse

inser tion, prevent inverse insertion

between phase and earthing lines.

Shor t circuit indication, dual color indication

for different states, red and green color.

Outer shell material: reinforced fire resistant.

PBT, in compliance wit h UL94-5V standard.

MB D C - 4 2- -

Surge protective device

Enterprise code

International 2 Pin number

International 3 Pin number

Lightningproof socket

Model and Signification

Indicate when placing an order

Please indicate the model, specification and quantity of SPD.

The following documents and accessories will be delivered together with goods.

Certificate of qualification 1 copy (each product) Operation manual 1 copy

(each product)

Technical Parameter

Protection grade

Response time

Nominal discharging current

Maxi discharging current

Voltage protective level

Maxi continuous operating voltage

Power source for network service

suitable for power supply systems

Model and specification MBD-C

TT/TN/IT

220V

330V

1kV

10kA

5kA

25ns

IP20

199 200

Page 25: Surge Protective Device -Meba

MBD-Z-300

Operation Elements

Non-electronic type, long working life,

only when lightning happen, the lighting

rod will be excited by itself, with prospective

disch-arging function, forwardly guide

the lightning system, after to withstand

repeated lightning discharging, it still has

such continuity of electric performances.

NB: The above data is calculated on basis of lightning rod height H = 5m.

Calculation formula of protective radius at prospective self-discharging

If prospective discharging time: T, then prior lead-up distance L=V* T, according

to calculation methods specified in NFC-17-102 standard, protective radius Rp come

from the following formula:

Representative= h(2D-H)+ L(2D+ L) h 5

D distance of lightning strike, determined by the grade of objects to be protected, for

category III object, D equal to 20m, 45m, 60m respectively.

H height from pin of lightning rod to the surface of protected object

T come from calculation and evaluation (as above sheet) V=106m/s L=V* T

Surge Protective Device

The appliance used to limit transient over voltage and dis charge

the surging current, it includes one of non-linear element at least.

Impulse Current

It determined by current peak value and electric charge Q, it shall

be performed according to the program for test of acting load. It is

used for SPD classification of Class I test.

Maximum Discharge Current Forclass Test

Passing through SPD, the peak value of current with 8/20 wave,

determined by the program for Class II acting load. Imax larger

than In.

Maximum Continuous Operating Voltage

Maximum AC virtual voltage or DC voltage allowed to be applied

on SPD continuously, the value equal to rated voltage.

Voltage Protection Level

It indicates the performance of SPD limiting the voltage between

terminals being connected. The value can be selected from the

sheet of prior values. This val ue shall be larger than highest

limited voltage.

MBD-Z-300 SeriesPre-discharge Lightning Rod

MB D Z 300- --

Lightning passing curr ent

Pre-discharge lightning rod

Surge protective device

Enterprise code

Product introduction Model and Signification

The strength of electric field between

central collection rod and exciter in the

lightning rod rise up quickly, and lead to

atmosphere ionization in the top end, it

will discharging in shorte st time accurately,

due a great deal of electricion existing,

which weaken the domino offect from

natural Corona, produce a prospective

discharging passage, it can quickly, safely

lead the lighting surging into ground.

Lightning passing current

Technical Parameter

Model and specification

Ground resistance requirement

Wind resistant strength

Height

Weight

Characteristics

Prospective discharging time T

MBD-Z-300

400kA

10

40m/s

67cm

8.5kg

52 s

Pre-discharge lightning type

5

6

7

8

10

15

20

42

42

43

43

43

44

45

5

7

8

10

15

20

45

57

58

59

60

63

65

70

5

8

10

15

20

45

60

64

67

68

72

75

83

85

MBD-Z-300

Sheet of height

from pin of

lightning rod to

ground versus

protective

radius (m)

Classification

Table of cross-refer Height and protect Radii(meter)

Category I protective

height D=20m

Related protective radius (m)

Category II protective

heightD=50m

Related protective radius (m)

Category III protective

height D=60m

Related protective radius (m)

Explanation Of SPD Technical Term

Voltage Switching Type SPD

SPD that it shows high impedance when there has no surging, and

becomes low impedance while surging voltage occurs. Voltage

switching type SPD generally composed of discharging gap, gas

discharging tube, thyratron (silicone controllable rectifier) and

three-ending bidirectional silicone switching element. Sometimes

it also call "short circuit type SPD" .

Voltage Limiting Type SPD

SPD that it shows high impedance when there has no surging, but

the impedance will decrease gradually while surging current and

voltage rise up. Common non-linear element: piezoresistance,

and clamping diode. Sometimes it also call "Clamping SPD".

Combination SPD

SPD constructed of voltage switching and voltage limiting elements.

The characteristics curve can take on the characteristics of voltage

switching or limiting type, or both.

Modes Of Protection

Protective element of SPD can be connected between phase line

to phase line (L-L), phase line to earth (L-PE), phase line to neutra l

line (L-N), neutral line to earthing line (N-PE) or their combination.

These connections call protection modes.

SPD Disconnector

The device that isolates SPD from power supply network

(interior and / or outer).

Nominal Discharge Current

The 8/20 wave current peak that passing by SPD, used for grading

SPD under class II test, or prospective treatment of SPD class I,

II test.

201 202

Page 26: Surge Protective Device -Meba

MBD-Z-300

Operation Elements

Non-electronic type, long working life,

only when lightning happen, the lighting

rod will be excited by itself, with prospective

disch-arging function, forwardly guide

the lightning system, after to withstand

repeated lightning discharging, it still has

such continuity of electric performances.

NB: The above data is calculated on basis of lightning rod height H = 5m.

Calculation formula of protective radius at prospective self-discharging

If prospective discharging time: T, then prior lead-up distance L=V* T, according

to calculation methods specified in NFC-17-102 standard, protective radius Rp come

from the following formula:

Representative= h(2D-H)+ L(2D+ L) h 5

D distance of lightning strike, determined by the grade of objects to be protected, for

category III object, D equal to 20m, 45m, 60m respectively.

H height from pin of lightning rod to the surface of protected object

T come from calculation and evaluation (as above sheet) V=106m/s L=V* T

Surge Protective Device

The appliance used to limit transient over voltage and dis charge

the surging current, it includes one of non-linear element at least.

Impulse Current

It determined by current peak value and electric charge Q, it shall

be performed according to the program for test of acting load. It is

used for SPD classification of Class I test.

Maximum Discharge Current Forclass Test

Passing through SPD, the peak value of current with 8/20 wave,

determined by the program for Class II acting load. Imax larger

than In.

Maximum Continuous Operating Voltage

Maximum AC virtual voltage or DC voltage allowed to be applied

on SPD continuously, the value equal to rated voltage.

Voltage Protection Level

It indicates the performance of SPD limiting the voltage between

terminals being connected. The value can be selected from the

sheet of prior values. This val ue shall be larger than highest

limited voltage.

MBD-Z-300 SeriesPre-discharge Lightning Rod

MB D Z 300- --

Lightning passing curr ent

Pre-discharge lightning rod

Surge protective device

Enterprise code

Product introduction Model and Signification

The strength of electric field between

central collection rod and exciter in the

lightning rod rise up quickly, and lead to

atmosphere ionization in the top end, it

will discharging in shorte st time accurately,

due a great deal of electricion existing,

which weaken the domino offect from

natural Corona, produce a prospective

discharging passage, it can quickly, safely

lead the lighting surging into ground.

Lightning passing current

Technical Parameter

Model and specification

Ground resistance requirement

Wind resistant strength

Height

Weight

Characteristics

Prospective discharging time T

MBD-Z-300

400kA

10

40m/s

67cm

8.5kg

52 s

Pre-discharge lightning type

5

6

7

8

10

15

20

42

42

43

43

43

44

45

5

7

8

10

15

20

45

57

58

59

60

63

65

70

5

8

10

15

20

45

60

64

67

68

72

75

83

85

MBD-Z-300

Sheet of height

from pin of

lightning rod to

ground versus

protective

radius (m)

Classification

Table of cross-refer Height and protect Radii(meter)

Category I protective

height D=20m

Related protective radius (m)

Category II protective

heightD=50m

Related protective radius (m)

Category III protective

height D=60m

Related protective radius (m)

Explanation Of SPD Technical Term

Voltage Switching Type SPD

SPD that it shows high impedance when there has no surging, and

becomes low impedance while surging voltage occurs. Voltage

switching type SPD generally composed of discharging gap, gas

discharging tube, thyratron (silicone controllable rectifier) and

three-ending bidirectional silicone switching element. Sometimes

it also call "short circuit type SPD" .

Voltage Limiting Type SPD

SPD that it shows high impedance when there has no surging, but

the impedance will decrease gradually while surging current and

voltage rise up. Common non-linear element: piezoresistance,

and clamping diode. Sometimes it also call "Clamping SPD".

Combination SPD

SPD constructed of voltage switching and voltage limiting elements.

The characteristics curve can take on the characteristics of voltage

switching or limiting type, or both.

Modes Of Protection

Protective element of SPD can be connected between phase line

to phase line (L-L), phase line to earth (L-PE), phase line to neutra l

line (L-N), neutral line to earthing line (N-PE) or their combination.

These connections call protection modes.

SPD Disconnector

The device that isolates SPD from power supply network

(interior and / or outer).

Nominal Discharge Current

The 8/20 wave current peak that passing by SPD, used for grading

SPD under class II test, or prospective treatment of SPD class I,

II test.

201 202

Page 27: Surge Protective Device -Meba
Page 28: Surge Protective Device -Meba
Page 29: Surge Protective Device -Meba