store fitout and joinery.compressed
TRANSCRIPT
UP
DNNorth North
I.T CarlowDept. Of Built Environment
Architectural Technology Year 3Technical Design and Detailing
Mark Grincell - C00162901
Project No.1 - Internal Fitout
Lecturer: Dan O'Sullivan, Noel DunneFinal Hand Up 21/10/2014
Sheet Index:
No.01 1.1 Joinery - Counter - General Arrangments
No.02 1.1 Joinery - Counter - Details
No.03 1.2 Joinery - Display Unit - General Arrangments
No.04 1.2 Joinery - Display Unit - Details
No.05 1.3 Joinery - Display Case - General Arrangments
No.06 1.3 Joinery - Display Case - Details
No.07 2.0 General Arrangments - Floor Plans/ Elevations
No.08 2.0 General Arrangments - Ceiling Plans/ Sections
No.09 3.1 Regulations - TGD M - Plans/Elevations/Details
No.10 3.2 Rgeulations - TGD B - Plans/ Elevations/Details
No.11 4.0 Technology Details - Suspended Ceiling
No.12 4.1 Technology Details - Internal Partitions
No.13 4.2 Technology Details - Raised Access Flooring
No.14 4.3 Technology Details - Stairs
No.15 6.0 MEP Layout - Plans/Ceilings
List Of Details:
Sheet No.2 (Section 1.1)- Counter Detail No.1- Counter Detail No.2- Counter Detail No.3- Counter Detail No.4- Counter Detail No.5- Counter Detail No.6
Sheet No.4 (Section 1.2)- Display Unit Detail No.1- Display Unit Detail No.2- Display Unit Detail No.3- Display Unit Detail No.4
Sheet No.6 (Section 1.3)- Display Case Detail No.1- Display Case Detail No.2- Display Case Detail No.3- Display Case Detail No.4- Display Case Detail No.5
Sheet No.9 (Section 3.1)-TGD B Detail No.1-TGD B Detail No.2-TGD B Detail No.3-TGD B Detail No.4
Sheet No.11 (Section 4.0)-Suspended Ceiling Detail No.1-Suspended Ceiling Detail No.2-Suspended Ceiling Detail No.3
Sheet No.12 (Section 4.1)- Internal Partition Details No.1- Internal Partition Details No.2- Internal Partition Details No.3- Internal Partition Details No.4- Internal Partition Details No.5- Internal Partition Details No.6
Sheet No.13 (Section 4.2)- Raised Access Floor Details No.1- Raised Access Floor Details No.2- Raised Access Floor Details No.3
Sheet No.14 (Section 4.3)-Stairs Detail No.1-Stairs Detail No.2-Stairs Detail No.3-Stairs Detail No.4
1248
1050
50
1026
1687
1481
600
350
1836
2036
1248
1050
50
301
950
600
1026563
1481
586
386
936
756
950
350
600
1248
586
386
350 950
350
600
756
93610
50
1248
7
No.01
2507
936
1694
1026
756
12
No.01
1No.02
2No.02
3No.02
3216
610
50
100 1836 100
2036
550
50
232 563 231
1651
350
6No.02
1026
950
Medium Density Fibreboard (MDF) With WhiteOak Veneer and Solid White Oak Edges.Measurements: 2440mm X 1220mm SheetsThickness Used:18mm
ESG TuffLam Safety Glass (Toughened Glass)Thickness Used: 9mmDisplay Unit on SISO PTO Sliders.
Philips iW Cove MX Powercore,White-light LED 6500 K
Shelving for TillElectrical Supply Unit Located Here
4No.02
5No.02
180 756
298
900
50
350 100 386 100
298
350
600
SISO PTO Drawer Sliders.Storage here for Materials
Marine plywood, WBPBase for Internal StructureThickness Used: 18mm
Medium Density Fibreboard (MDF) With WhiteOak Veneer and Solid White Oak Edges.
2Elevation
Elevation 3
Eleva
tion
4 5Ele
vatio
n
Push Button Alarm SystemWired to Shop Security SystemHidden from view, Easily Accessible
100 386 100586
600
350
1248
756
525 232
260
938
50
Medium Density Fibreboard (MDF) WithWhite Oak Veneer and Solid White Oak Edges.Measurements: 2440mm X 1220mm SheetsThickness Used:18mm, 25mm
ESG TuffLam Safety Glass(Toughened Glass)
Thickness Used: 6mm
Philips iW Cove MXPowercore, White-light
LED 6500 K
Interl StructureWhite Deal (Rough Cut)
Thickness Used: 25mm x 25mm
Shelving for Till*Electrical Supply Needed.
Electric Supply Unit for TillReassessed into MDF
Panel
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
20/1
0/20
14 1
5:51
:25
1.1 Joinery - Counter - GA
No.1
07/10/2014
No.01
No.01
1.1 Joinery - Counter - 3D Isometric View0
1 : 20No.01
1.1 Joinery - Counter - Front Elevation2
1 : 20No.01
1.1 Joinery - Counter - Rear Elevation3
1 : 20No.01
1.1 Joinery - Counter - Left Elevatin5
1 : 20No.01
1.1 Joinery - Counter - Right Elevation4
1 : 20No.01
1.1 Joinery - Counter - Plan1
1 : 10No.01
1.1 Joinery - Counter - Section AA6 1 : 10No.01
1.1 Joinery- Counter - Section BB7
Specifications:
Timber:Medium Density Fibreboard (MDF) With WhiteOak Veneer and Solid White Oak Edges.Measurements: 2440mm X 1220mm SheetsThickness Used:18mm
Marine plywood, WBP (weather and Boil proof)phenolic glue.Measurements: 2440mm X 1220mmThickness Used: 18mm, 25mm
White Deal (Rough Cut)Thickness Used: 25mm x 25mm, 50mm x 25mm,50mm x 100mm Battens.
Glass:ESG TuffLam Safety Glass (Toughened Glass)Thickness Used: 9mm, 6mm
Fittings:Point Fixture 30mm Diameter - M8 x 40mm Bolt- 303 Polished Stainless Steel Finish. Suited for 6 -16mm Glass.
FIX FX19 PSF Panel Screw System.303 Grade Stainless Steel (Polished) InteriorApplication. 10g Countersunk Screw Required19mm Diameter x 8mm Thickness
SISO Push to Open (PTO) 4500 Drawer Slider,2mm PTO.Cold Rolled Steel 1.2mm. Fixing via ChipboardScrews 4mm Dia.Travel: 600mm.
Lighting:Philips iW Cove MX Powercore, White-light LED6500 K. 100–240 V AC, auto-switching, 50-60Hz, White powder-coated finish.
1 : 20No.01
1.1 Joinery - Counter - Section AA - Lighting8
1 : 20No.01
1.1 Joinery- Counter -Section BB - Lighting9
No.01
1.1 Joinery - Counter - Interior View11
1 : 10No.01
1.1 Joinery - Counter - Section CC12
MDF Panel White Oak Veneer SecuredUsing FIX Panel Screw System.
303 Grade Stainless Steel (Polished)
Display Drawer, SISO Push to Open Sliders.Interior: Black Velvet Covering
Lighting under the Display Unit: Philips iWCove MX Powercore, White-light LED 6500 K.
ESG TuffLam Safety Glass (ToughenedGlass)
6mm Secured Via 30mm Stainless SteelPoint Fixtures
ESG TuffLam Safety Glass (ToughenedGlass)9mm secured via 30mm Point Fixtures
1 : 20No.01
1.1 Joinery - Counter -Section CC - Lighting13
Lighting:Philips iW Cove MXPowercore, White-
light LED 6500 K.- 70 Degrees Beam
Angle(Electrical Wiring
requires consultation.)
Luminaire Wiring
Light Area
Drawer Storage , SISO PTOSliders
Shelving for TillElectrical Supply UnitLocated Here
50
50
25 25
1220
18 153
2514
918
18
89
150
18
ESG "Tufflam Glass"12mm Tempered GlassFixing: Via Point FixtureFinish: Polished
30mm Point FixtureFixing: Oak Veneer MDF PanelFinish: Polished Stainless Steel
19mm Panel Screw SystemFixing: Secure MDF Panel(White Oak Veneer)To Internal StructureFinish: Polished Stainless Steel
25mm x 25mm Internal Structure BattenFixing : To Joiner SpecFinished: N/A
18mm MDF Panel White OakVeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
Philips iW Cove MX Powercore,White-light LED 6500 K.
Fixing: Secured to MDF undersideFinished:White powder-coated
18mm MDF Panel White OakVeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
19mm Panel Screw SystemFixing: Secure MDF Panel
(White Oak Veneer)To Internal Structure, PlywoodFinish: Polished Stainless Steel
232
182
18mm Plywood x2Fixing: To internal Structure
Finish: Plain
200
1825
25
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
25mm x 25mm Internal Structure BattenFixing : To Joiner SpecFinished: N/A
5075
2518
43
18 50
68
2518
18
61
100
19mm Panel Screw SystemFixing: Secure MDF Panel
(White Oak Veneer) ToInternal Structure
Finish: Polished StainlessSteel
25mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
Philips iW Cove MXPowercore, White-light
LED 6500 K.Fixing: Secured to MDF
undersideFinished:White powder-
coated
18mm MDF Panel WhiteOak Veneer
Fixing: Via Panel ScrewSystem
Finish: Plain (Wood Grain)
25mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
50mm x 100mm Structure BattenFixing : To Joiner SpecFinished: N/A
100
1220
25
18
18 14 18 25
915
318
450
1850
100
25
37
30mm Point FixtureFixing: Oak Veneer MDF PanelFinish: Polished Stainless Steel
ESG "Tufflam Glass"12mm Tempered GlassFixing: Via Point FixtureFinish: Polished
19mm Panel Screw SystemFixing: Secure MDF Panel(White Oak Veneer)To Internal StructureFinish: Polished StainlessSteel
50mm x 25mm InternalStructure BattenFixing : To Joiner SpecFinished: N/A
18mm MDF Panel WhiteOak VeneerFixing: Via PanelScrew SystemFinish: Plain (Wood Grain)
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
50mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
Philips iW Cove MXPowercore, White-lightLED 6500 K.Fixing: Secured to MDFundersideFinished:White powder-coated
3212
1
18mm MDF PanelWhite Oak Veneer
Fixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
Black FeltLayed for interior of display
case
ESG "Tufflam Glass"9mm Tempered GlassFixing: Via Point Fixture
Finish: Polished
SISO Push to Open SliderModel: PTO 4500Travel: 650mm
Stainless Steel Strip
10030
25mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
25mm x 25mm Internal Structure BattenFixing : To Joiner SpecFinished: N/A
25
1220
25
37
140
5
913
25 18
1812
1
ESG "Tufflam Glass"12mm Tempered GlassFixing: Via Point FixtureFinish: Polished
Black FeltLayed for interior of
display case
25mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
18mm MDF Panel White OakVeneer
Fixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
ESG "Tufflam Glass"9mm Tempered GlassFixing: Via Point Fixture
Finish: Polished
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
Stainless Steel Strip
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
19mm Panel Screw SystemFixing: Secure MDF Panel (WhiteOak Veneer)To Internal StructureFinish: Polished Stainless Steel
30mm Point FixtureFixing: Oak Veneer MDF PanelFinish: Polished Stainless Steel
15
515
05
150
515
05
500
19mm Panel Screw SystemFixing: Secure MDF Panel(White Oak Veneer)To Internal StructureFinish: Polished StainlessSteel
19mm Panel Screw SystemFixing: Secure MDF Panel(White Oak Veneer)To Internal StructureFinish: Polished Stainless Steel
18mm MDF Panel White OakVeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain
18mm MDF Panel WhiteOak VeneerFixing: Via Panel ScrewSystemFinish: Plain (Wood Grain
SISO Push to Open SliderModel: PTO 4500Travel: 650mm
132
1813
218
1813
215
25
1825
25 18
2520
25
100
75
1224
912
2512
818
450
7
2525
1825
18 25 18
25
30
18 14 18
SISO Push to Open SliderModel: PTO 4500
Travel: 650mm
18mm MDF PanelWhite Oak Veneer
Fixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
18mm MDF Panel WhiteOak VeneerFixing: Via PanelScrew SystemFinish: Plain (WoodGrain)
50mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
19mm Panel Screw SystemFixing: Secure MDF Panel (White Oak Veneer)To Internal StructureFinish: Polished Stainless Steel
ESG "Tufflam Glass"12mm Tempered GlassFixing: Via Point FixtureFinish: Polished
30mm Point FixtureFixing: Oak Veneer MDF PanelFinish: Polished Stainless Steel
Stainless Steel Strip
ESG "Tufflam Glass"9mm Tempered GlassFixing: Via Point FixtureFinish: Polished
Black FeltLayed for interior of display case
25mm MDF Panel WhiteOak Veneer
Fixing: Via PanelScrew System
Finish: Plain (Wood Grain)
18mm MDF Panel WhiteOak Veneer
Fixing: Via PanelScrew System
Finish: Plain (Wood Grain)
50mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
50mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
1 : 2
20/1
0/20
14 1
5:23
:33
1.1 Joiner - Counter - Details
No.1
07/10/2014
No.02
1 : 2No.02
1.1 Joinery - Counter - Detail No.11 1 : 2No.02
1.1 Joinery - Counter - Detail No.22
1 : 2No.02
1.1 Joinery - Counter - Detail No.33
1 : 2No.02
1.1 Joinery- Counter - Detail No.44
1 : 2No.02
1.1 Joinery- Counter - Detail No.55
Specifications:
Timber:Medium Density Fibreboard (MDF) With WhiteOak Veneer and Solid White Oak Edges.Measurements: 2440mm X 1220mm SheetsThickness Used:18mm, 25mm
Marine plywood, WBP (weather and Boilproof) phenolic glue.Measurements: 2440mm X 1220mmThickness Used: 18mm
White Deal (Rough Cut)Thickness Used: 25mm x 25mm, 50mm x25mm, 50mm x 100mm Battens.
Glass:ESG TuffLam Safety Glass (Toughened Glass)Thickness Used: 9mm, 6mm
Fittings:Point Fixture 30mm Diameter - M8 x 40mm Bolt- 303 Polished Stainless Steel Finish. Suited for 6- 16mm Glass.
FIX FX19 PSF Panel Screw System.303 Grade Stainless Steel (Polished) InteriorApplication. 10g Countersunk ScrewRequired19mm Diameter x 8mm Thickness
SISO Push to Open (PTO) 4500 Drawer Slider,2mm PTO.Cold Rolled Steel 1.2mm. Fixing via ChipboardScrews 4mm Dia.Travel: 600mm.
Lighting:Philips iW Cove MX Powercore, White-light LED6500 K. 100–240 V AC, auto-switching, 50-60Hz, White powder-coated finish.
1 : 2No.02
1.1 Joinery - Counter - Detail No.66
Luminaire Wiring
Light Area
50
1700
400
200
200
200
200
200
200
400 400
400
1100
800
5020
011
0040
0
1700
200
400
400400400
600
800
5020
0
1100
1700
400 400400
400
600100
400 400
200
400
200
1700
5020
020
0
600800
1500
2Elevation
Elevation 3
5Ele
vatio
n
Eleva
tion
4
8
No.03
9
No.03
400 400
400
400 400
400
400
400
5
No.04
1No.04
2No.04
3No.04
1700
1500
100
100
800
400
1300
600
Medium Density Fibreboard (MDF)With White Oak Veneer and Solid
White Oak Edges.Measurements: 2440mm X1220mm Sheets Thickness
Used:18mm
ESG TuffLam Safety Glass(Toughened Glass)
Thickness Used: 9mm
Philips iW CoveMX Powercore,White-light LED6500 K
Interl StructureWhite Deal(Rough Cut)Thickness Used:25mm x 25mm
4No.04
1700
400
1100
400
400 400
800
Medium DensityFibreboard
(MDF) With WhiteOak Veneer
and Solid WhiteOak Edges.
Philips iW Cove MXPowercore, White-light LED 6500 K
Interl StructureWhite Deal (Rough Cut)Thickness Used: 25mmx 25mm
SISO PTO Drawer Sliders.On Side of Unit for
Opening Display
Lighting:Philips iW Cove MXPowercore, White-lightLED 6500 K.- 70 Degrees Beam Angle(Electrical Wiring requiresconsultation.)
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
21/1
0/20
14 0
8:10
:44
1.2 Joinery - Display Unit -GA
No.1
07/10/2014
No.03
Specifications:
Timber:Medium Density Fibreboard (MDF) With WhiteOak Veneer and Solid White Oak Edges.Measurements: 2440mm X 1220mm SheetsThickness Used:18mm
Marine plywood, WBP (weather and Boil proof)phenolic glue.Measurements: 2440mm X 1220mmThickness Used: 18mm, 25mm
White Deal (Rough Cut)Thickness Used: 25mm x 25mm, 50mm x 25mm,50mm x 100mm Battens.
Glass:ESG TuffLam Safety Glass (Toughened Glass)Thickness Used: 9mm, 6mm
Fittings:Point Fixture 30mm Diameter - M8 x 40mm Bolt- 303 Polished Stainless Steel Finish. Suited for 6 -16mm Glass.
FIX FX19 PSF Panel Screw System.303 Grade Stainless Steel (Polished) InteriorApplication. 10g Countersunk Screw Required19mm Diameter x 8mm Thickness
SISO Push to Open (PTO) 4500 Drawer Slider,2mm PTO.Cold Rolled Steel 1.2mm. Fixing via ChipboardScrews 4mm Dia.Travel: 600mm.
Lighting:Philips iW Cove MX Powercore, White-light LED6500 K. 100–240 V AC, auto-switching, 50-60Hz, White powder-coated finish.
Luminaire Wiring
Light Area
1 : 20No.03
1.2 Joinery - Display Unit - Front Elevation1
1 : 20No.03
1.2 Joinery - Display Unit - Left Elevation2 1 : 20No.03
1.2 Joinery - Display Unit - Rear Elevation3
1 : 20No.03
1.2 Joinery - Display Unit - Right Elevation4
1 : 20No.03
1.2 Joinery - Display Unit - Plan6
No.03
1.2 Joinery - Display Unit - Interior View7
1 : 10No.03
1.2 Joinery - Display Unit - Section AA8 1 : 10No.03
1.2 Joinery - Display Unit - Section BB9 1 : 20No.03
1.2 Joinery - Display Unit - Section AA - Lighting10 1 : 20No.03
1.2 Joinery - Display Unit - Section BB - Lighting11
No.03
1.2 Joinery - Display Unit - 3D Isometric View12
The Lighting for the Display will be Directed Down From Above
MDF Panel White Oak Veneer SecuredUsing FIX Panel Screw System.303 Grade Stainless Steel (Polished)
MDF Panel White Oak VeneerSecured Using FIX Panel Screw
System.303 Grade Stainless Steel (Polished)
Display Drawer, SISOPush to Open Sliders.
ESG TuffLam Safety Glass(Toughened Glass)
9mm
19mm Panel Screw SystemFixing: Secure MDF Panel
(White Oak Veneer)To Internal Structure
Finish: Polished Stainless Steel
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
25mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
25mm x 25mm Internal Structure BattenFixing : To Joiner SpecFinished: N/A
2518
30
ESG "Tufflam Glass"6mm Tempered GlassFixing: Base, Glue and
Oak WedgeFinish: Polished
Mitre Joint at ConnectionsGlass Panels. ConnectionSealed by UV Glass Glue.
66 6
20 1825
6
6
5075
25 18
43
1850
68
2518
18
61
100
19mm Panel Screw SystemFixing: Secure MDF Panel(White Oak Veneer) ToInternal StructureFinish: Polished StainlessSteel
25mm x 25mm InternalStructure BattenFixing : To Joiner SpecFinished: N/A
Philips iW Cove MXPowercore, White-lightLED 6500 K.Fixing: Secured to MDFundersideFinished:White powder-coated
18mm MDF Panel WhiteOak VeneerFixing: Via Panel ScrewSystemFinish: Plain (Wood Grain)
25mm x 25mm InternalStructure BattenFixing : To Joiner SpecFinished: N/A
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
50mm x 100mm Structure BattenFixing : To Joiner Spec
Finished: N/A
100
19mm Panel Screw SystemFixing: Secure MDF Panel
(White Oak Veneer)To Internal Structure
Finish: Polished Stainless Steel
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
25mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
18mm MDF Panel White OakVeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
25mm x 25mm InternalStructure BattenFixing : To Joiner SpecFinished: N/A
30
ESG "Tufflam Glass"6mm Tempered GlassFixing: Base, Glue and
Oak WedgeFinish: Polished
66 6
20 1825
19mm Panel Screw SystemFixing: Secure MDF Panel
(White Oak Veneer)To Internal Structure
Finish: Polished Stainless Steel
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
25mm x 25mm InternalStructure Batten
Fixing : To Joiner SpecFinished: N/A
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
25mm x 25mm Internal Structure BattenFixing : To Joiner SpecFinished: N/A
30
ESG "Tufflam Glass"6mm Tempered GlassFixing: Base, Glue and
Oak WedgeFinish: Polished
66 6
18
Mitre Joint at ConnectionsGlass Panels. ConnectionSealed by UV Glass Glue.
6
2518
20
2518
19mm Panel Screw SystemFixing: Secure MDF Panel
(White Oak Veneer)To Internal Structure
Finish: Polished Stainless Steel
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
25mm x 25mm InternalStructure BattenFixing : To Joiner SpecFinished: N/A
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw SystemFinish: Plain (Wood Grain)
25mm x 25mm Internal Structure BattenFixing : To Joiner SpecFinished: N/A
30
ESG "Tufflam Glass"6mm Tempered GlassFixing: Base, Glue and
Oak WedgeFinish: Polished
Mitre Joint at ConnectionsGlass Panels. ConnectionSealed by UV Glass Glue.
66 6
17.8
25
6
18
25
SISO Push to Open SliderModel: PTO 4500
Travel: 650mmSecured to Structure Inside
18
30
18mm MDF Panel White Oak VeneerFixing: Via Panel Screw System
Finish: Plain (Wood Grain)
1700
1500
100
100
800
400
1300
600
Medium Density Fibreboard (MDF)With White Oak Veneer and Solid
White Oak Edges.Measurements: 2440mm X1220mm Sheets Thickness
Used:18mm
ESG TuffLam Safety Glass(Toughened Glass)
Thickness Used: 9mm
Philips iW CoveMX Powercore,White-light LED6500 K
Interl StructureWhite Deal(Rough Cut)Thickness Used:25mm x 25mm
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
21/1
0/20
14 0
8:12
:38
1.2 Joinery - Display Unit -Details
No.1
07/10/2014
No.04
1 : 2No.04
1.2 Joinery - Display Unit - Detail No.11 1 : 2No.04
1.2 Joinery - Display Unit - Detail No.22
1 : 2No.04
1.2 Joinery - Display Unit - Detail No.33 1 : 2No.04
1.2 Joinery - Display Unit - Detail No.44
Specifications:
Timber:Medium Density Fibreboard (MDF) With WhiteOak Veneer and Solid White Oak Edges.Measurements: 2440mm X 1220mm SheetsThickness Used:18mm, 25mm
Marine plywood, WBP (weather and Boilproof) phenolic glue.Measurements: 2440mm X 1220mmThickness Used: 18mm
White Deal (Rough Cut)Thickness Used: 25mm x 25mm, 50mm x25mm, 50mm x 100mm Battens.
Glass:ESG TuffLam Safety Glass (Toughened Glass)Thickness Used: 9mm, 6mm
Fittings:Point Fixture 30mm Diameter - M8 x 40mm Bolt- 303 Polished Stainless Steel Finish. Suited for 6- 16mm Glass.
FIX FX19 PSF Panel Screw System.303 Grade Stainless Steel (Polished) InteriorApplication. 10g Countersunk ScrewRequired19mm Diameter x 8mm Thickness
SISO Push to Open (PTO) 4500 Drawer Slider,2mm PTO.Cold Rolled Steel 1.2mm. Fixing via ChipboardScrews 4mm Dia.Travel: 600mm.
Lighting:Philips iW Cove MX Powercore, White-light LED6500 K. 100–240 V AC, auto-switching, 50-60Hz, White powder-coated finish.
1 : 10No.04
1.2 Joinery - Display Unit - Section AA Details5
UP
DNDN
UP
2000
4500
5050
4011
3100
1672
4500
5050
3000
1885
1500
1000
7 m²Staff Canteen
No.7
6 m²Safe Room
No.8
5 m²WCNo.6
3 m²StoreNo.5
21 m²Hallway
No.3
22 m²Workshop
No.4
North
50504115
9184
2700
1270
0
1710
5065
1900
1000
300 1000 1515 1000
935
1200
47 m²Shop Floor
No.1
7 m²Consultation Room
No.2
North
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level -1
-3000
2.2 GA - Plan -Level -1
-3000
Solid Oak WindowsHeight: 1500mmWidth: 1000mm
Triple Glazed Unit
Veneer Oak MDF FireRated Door.
Head Height: 2200mmWidth: 1500mm
30min Fire Resistance
1500
2200
1000
1500
Existing BrickworkWall 215mm
Existing Brick WorkWall 215mm
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level -1
-3000
2.2 GA - Plan -Level -1
-3000
Basement
Solid Oak WindowsHeight: 1500mmWidth: 1000mmTriple Glazed Unit
Solid Oak Double DoorHead Height: 2200mmWidth: 1900mmTriple Glazed Unit
2200
700
10411000 19731900
5050
4115
9184
2700
1710
Existing Windows Were Removed and theVoid was Filled with a Standard BrickworkWall to Match the Existing Structure
Triple Glazed Solid White Oak SashWindows Replace the Existing OnesMeasurements: 1000mm x 1500mmThe Cill Height must be raised to 1200 toaccommodate the Raised AccessFlooring
Existing Shop Front Door and GlazingRemoved and Replaced by StandardBrickwork Wall to Match the existingStructure.
Solid Oak Windows and Solid OakDouble Door will Replace the Entrance.
The Door will be 2200mm HH, 1900mmWidth Which will Comply with TGD M.
Triple Glazed Solid White Oak SashWindows Replace the Existing OnesMeasurements: 1000mm x 1500mm
The Existing WC and Staff Kitchen willbe moved down stairs and theconsultation Room will be moved tothe Ground Floor.The Reasoning behind this is the Toiletand Kitchen are a Staff only facilityand having the consultation RoomUp Stairs will allow the Whole Public toaccess it.
A new Stairs will have to replace theExisting Hatch to Allow Access intothe Basement Level.The Stairs will be Designed so to bean Ambient Stairs.It Will Also Act as an OptionalEscape Route, Leading Directly tothe Final Exit
Existing Projects in the Brickwork Wallwill be Removed.(Required Structural Analysis)
This will allow easy to line the wall andgain space as the Floor Area is quiteSmall.Existing Projects in the Brickwork
Wall will be Removed.Possible Fire Place.(Required Structural Analysis)
This will allow easy to line the walland gain space as the Floor Areais quite Small.
5065
Raised Access Floor Area to Levelthe Area and over Come theExisting Stepped Area.Platform Lift Will be placed toallow Wheelchair Access.
North
2000
4500
Existing Rear Door Replaced with Oak MDFFire Rated Door.Width: 1500mm to Allow Access of Materialsand Machinery.Door will be used as Rear Exit but also as anEmergency Escape.
A new Stairs will have to replace theExisting Hatch to Allow Access into theBasement Level.The Stairs will be Designed so to be anAmbient Stairs.It Will Also Act as an Optional EscapeRoute, Leading Directly to the Final Exit
Existing Projects in the Brickwork Wallwill be Removed.(Required Structural Analysis)
This is Required to Allow the StairsStructure to be Installed.
The Basement Boundary Extends Furtherthen the Ground Floor Above.
The Above Wall Sits on an Concrete Floorwhich close the gap between thebasement retaining wall and Front Wall.
All Existing Internal Walls will be taken out.New Steel Partitions will Replace these.
New Oak Veneer MDF 3Omin FireRated Doors Will be Installed intothe Stud Partitions.Width: 1000mm to meet TGD M andB.
A One Sided Partition Will beConstructed here to allow a run forservices as the Kitchen/ Canteenare along this Side of The Building.
The WC will be located here. Thiswill be fully AccessibleThe Services will Run In The OneSides Partition.
The Work Shop is a High Risk Area. Thisneeds to be a Secure Area as well asneeds 60min Fire Resistance as wellneeds its own Ventilation.
Existing Building on Both Sides of theBuilding. Terraced Building.
5050
4011
3100
1672
4500
5050
3000
North
Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel with
Catalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal, 601.5mm Rise.
Oak Veneer MDF 3Omin Fire Rated DoorsWill be Installed into the Stud Partitions.Width: 1000mm to meet TGD M and B.
Stairs Structure 31mm Toughened Glazing, StainlessSteel Hand Rail, Treads Solid White Oak Panel, 30mm x1200mm x 300mm, Held in Place by PanelScrew/Tread System 19mm Dia.
Gyproc MF Suspended Panel System, 600mm x 600mmFreshtone panel, Shadow Gap Around Edges.
Oak Veneer MDF 3Omin Fire Rated DoorsWill be Installed into the Stud Partitions.Width: 1000mm to meet TGD M and B.
Pilkington LCD FILM Glass12mm, Partition System. MildSteel Frame, 100mmx50mm
Gyproc Suspended Ceiling System, Plasterboard9mm, 15mm MDF Oak Veneer Feature Supportedby Gyproc Framing System (GL5)
Steel Stud System (50mm x50mm C-Channel) using:Gyproc Plasterboard
Gyproc MF Suspended Panel System,600mm x 600mm Freshtone panel,
Shadow Gap Around Edges.
225mm Wooden Joists 500c/c, Lath andPlaster removed and 12.5mm + 12.5mmGyproc Fibreboard replaces it securedto Joists, 2.5mm Plaster Skim.
Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF Oak VeneerFeature Supported by Gyproc FramingSystem (GL5)
225mm Wooden Joists 500c/c, Lath andPlaster removed and 12.5mm + 12.5mm
Gyproc Fibreboard replaces it secured toJoists, 2.5mm Plaster Skim.
215mm Brickwork, 15mmGyproc Plasterboard, 2.5mm
Plaster Skim..
Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF OakVeneer Feature Supported by GyprocFraming System (GL5)
Gyproc MF Suspended PanelSystem, 600mm x 600mmFreshtone panel, 10mm ShadowGap Around Edges
Steel Stud System (50mm x 50mm C-Channel) using: Gyproc Plasterboard
Pilkington LCD FILM Glass 12mm, PartitionSystem. Mild Steel Frame, 100mmx50mm
Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Board Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal
New Oak Veneer MDF 3Omin Fire Rated DoorsWill be Installed into the Stud Partitions. Width:1000mm meet TGD M and B.
Gyproc MF Suspended Panel System,600mm x 600mm Freshtone panel,
10mm Shadow Gap Around Edges
Elevation North
Elevation South
Eleva
tion
Wes
t
Eleva
tion
East
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
20/1
0/20
14 1
5:55
:42
2.0 GA - Floor Plans /Elevations
No.1
07/10/2014
No.07
1 : 100No.07
2.2 GA - Plan - Level -11
1 : 100No.07
2.2 GA - Plan - Level 02
1 : 50No.07
2.1 GA - South Elevation6 1 : 50No.07
2.1 GA- North Elevation7
1 : 100No.07
2.1 GA - Alterations - Ground Floor Level8
1 : 100No.07
2.1 GA - Alterations - Basment Level9
Specifications:
Wall Build Up:Existing: Wall Build Up 2015mm Brickwork,Lime Based Mortar.
New: 215mm Brickwork, 15mm GyprocPlasterboard, 2.5mm Plaster Skim.
Floor Build Up:Existing: 225mm Wooden Joists 500 c/c, Lathand Plaster Finish.
New: 225mm Wooden Joists 500c/c, Lathand Plaster removed and 12.5mm + 12.5mmGyproc Fibreboard replaces it secured toJoists, 2.5mm Plaster Skim.
Suspended Ceiling Build Up:Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF Oak VeneerFeature Supported by Gyproc FramingSystem (GL5)
Gyproc MF Suspended Panel System,600mm x 600mm Freshtone panel, ShadowGap Around Edges.
Partition Build Up:Various Steel Stud System (50mm x 500mmC-Channel) using:
- Gyproc Fireboard,One Sided:Skim 2.5mm Plaster 15mm +15mm 2.5mmPlaster Skim, Shadow gap, (90MIN)
- Gyproc Wallboard, Two sided:Plaster Skim 2.5mm,, 2x12.5mm, 50mm Stud,2x12.5mm, Plaster Skim 2.5mm, (90MIN)
Pilkington LCD FILM Glass 12mm, PartitionSystem. Mild Steel Frame, 100mmx50mm
Internal Doors:New Oak Veneer MDF 3Omin Fire RatedDoors Will be Installed into the Stud Partitions.Width: 1000mm to meet TGD M and B.
External Doors:Front Door - Solid Oak Double Door HeadHeight: 2200mm Width: 1900mm TripleGlazed Unit, 30min Fire Rated.
Back Door - Veneer Oak MDF Fire RatedDoor. Head Height: 2200mm Width: 1500mm30min Fire Rated.
External Windows:Solid Oak Windows Height: 1500mm Width:1000mm Triple Glazed Unit
Raised Access Flooring:Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal, 601.5mm Rise.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatalogue Finish: Calcutta GoldButech 10mm Catches System.
Stairs Construction:Stairs Structure 31mm Toughened Glazing,Stainless Steel Hand Rail, Treads Solid WhiteOak Panel, 30mm x 1200mm x 300mm, Heldin Place by Panel Screw/Tread System19mm Dia.
1 : 50No.07
2.1 Internal Elevation - East3
1 : 50No.07
2.1 Internal Elevation - North4 1 : 50No.07
2.1 Internal Elevation - South5
1 : 50No.07
2.1 Internal Elevation - West10
Existing Construction (Demolished):
New Construction:
Butech 15k Panel System, Thickness 12.5mm, 600mm x600mm Calcium Sufile Core with Catalogue Finish: CalcuttaGold Butech 10mm Catches System.
Front Door - Solid OakDouble Door HeadHeight: 2200mm Width:1900mm Triple GlazedUnit, 30min Fire Rated
The Ceiling Requires a 600mm x 600mm Grid SystemThe Ceiling is a Duel Level Ceiling:
-The Plasterboard at -350 From First Floor Level
-The MDF White Oak Veneer at -600 from First Floor Level
Gyproc MF Suspended PanelSystem, 600mm x 600mmFreshtone panel, Shadow GapAround Edges
Gyproc Suspended Ceiling Grid System
- 9mm Plasterboard 9mm- Supported by Gyproc Framing System600mm x 600mm-150mm Bulk Head Upstanding-350mm from FFL
Gyproc Suspended Ceiling System
-15mm MDF Oak Veneer Feature-Supported by Gyproc Framing System600mm x 600mm-150mm Bulk Head Upstanding-600mm from FFL
1020
0
3000 1200
8400
4243
98.13
°81.87°
Gyproc Suspended Ceiling Grid System-9mm Plasterboard
Gyproc Suspended Ceiling System-15mm MDF Oak Veneer Feature
500 2994 1471
3966
4105
1710
North
Shadow GapGrid
Framing System
Freshtone Panel
Shadow Gap Feature 10mm
Shadow Gap Bead
Freshtone Panel
4450
5050
1572
1950
3000
4228
148
1803
1793
2990
2255
5030
4430
1930
1552
2520
4416
4667
1783
1783
2980
2234 18
15
Gyproc MF Suspended Panel System.600mm x 600mm Freshtone panelThickness 10mm, Diamond White vinyl-faced
-10mm Shadow Gap Around Edges
Suspended Aluminium Grid System, secured toplasterboard above.Shadow Line Grid
The Hall way that thestairs occupies has nosuspended Ceiling, It hasa plaster finish.
North
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level -1
-3000
2929
3000
2706
2200
2929
2200
1000
900
2419
220025
91
2400
1No.11
3No.13
250
276.
588
.5
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level -1
-3000
2929
900
1940
.5
1993
657
2705
.5
2200
2929
3000
2200
2200
1000
2705
.5
294.
5
200
205.
5
2500
235.
5
1No.13
2No.11
5No.12
4No.11
2No.13
1No.12
3No.12
2314
1150
276.
5 338.
5
1248
1066
600
3
No.08
4
No.08
10
No.08
Level 13200
Level 13200
204
175
350
1164
179
265 503485668
Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF OakVeneer Feature Supported by GyprocFraming System (GL5)
Gyproc MFSuspended PanelSystem, 600mm x600mm Freshtonepanel, ShadowGap Around Edges.
Stairs Structure 31mm Toughened Glazing,Stainless Steel Hand Rail, Treads Solid WhiteOak Panel, 30mm x 1200mm x 300mm, Heldin Place by Panel Screw/Tread System19mm Dia.
Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal, 601.5mm Rise.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatalogue Finish: Calcutta GoldButech 10mm Catches System.
Oak Veneer MDF 3Omin Fire Rated DoorsWill be Installed into the Stud Partitions.
Width: 1000mm meet TGD M and B.
Gyproc Suspended Ceiling System, Plasterboard9mm, 15mm MDF Oak Veneer FeatureSupported by Gyproc Framing System (GL5)
Gyproc MF Suspend Panel System, 600mmx 600mm Freshtone panel, Shadow Gap
Around Edges.
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level -1
-3000
Stairs Construction:Stairs Structure 31mm Toughened Glazing, Stainless Steel Hand Rail, Treads Solid White Oak Panel, 30mm x 1200mm x300mm, Held in Place by Panel Screw/Tread System 19mm Dia.
The Stairs Meets all the requirements of TGD K the stairs will meet the requirements set out in TGD M , to Allow Accessto People of All Disability, it will not be an Ambient Disability Stairs but will meet the Highest Standard.
Steps: 18 Rises in TotalLanding: 1000mm1200mmRise: 170mmGoing: 300mmWidth 1200mm
900
2706
900
1000
1053
167
275300
170
100012 Steps
2000
1706
6 Steps
31mm Toughened Glass ESG
Solid White oak Panel,30mm Thick x 300mm
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
20/1
0/20
14 1
5:56
:13
2.0 GA - Ceiling Plans /Sections
No.1
07/10/2014
No.08
1 : 100No.08
2.2 GA - Plan - Level 01
1 : 100No.08
2.2 GA - Plan - Level -12
Specifications:
Wall Build Up:Existing: Wall Build Up 2015mm Brickwork, LimeBased Mortar.
New: 215mm Brickwork, 15mm GyprocPlasterboard, 2.5mm Plaster Skim.
Floor Build Up:Existing: 225mm Timber Joists 500 c/c, Lathand Plaster Finish UNder Joists
New: 225mm Wooden Joists 500c/c, Lath andPlaster removed and 12.5mm + 12.5mmGyproc Fireboard replaces it secured to Joists,2.5mm Plaster Skim.
Suspended Ceiling Build Up:Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF Oak VeneerFeature Supported by Gyproc Framing System(GL5)
Gyproc MF Suspend Panel System, 600mm x600mm Freshtone panel, Shadow Gap AroundEdges.
Partition Build Up:Various Steel Stud System (50mm x 50mm C-Channel) using:
- Gyproc Fireboard,One Sided:Skim 2.5mm Plaster 15mm +15mm 2.5mmPlaster Skim, Shadow gap, (90MIN)
- Gyproc Wallboard, Two sided:Plaster Skim 2.5mm,, 2x12.5mm, 50mm Stud,2x12.5mm, Plaster Skim 2.5mm, (90MIN)
Pilkington LCD FILM Glass 12mm, PartitionSystem. Mild Steel Frame, 100mmx50mm
Internal Doors:New Oak Veneer MDF 3Omin Fire Rated Doorand Frame Will be Installed into the StudPartitions. Width: 1000mm meet TGD M and B.
External Doors:Front Door - Solid Oak Double Door HeadHeight: 2200mm Width: 1900mm Triple GlazedUnit, 30min Fire Rated.
Back Door - Veneer Oak MDF Fire Rated Door.Head Height: 2200mm Width: 1500mm 30minFire Rated.
External Windows:Solid Oak Windows Height: 1500mm Width:1000mm Triple Glazed Unit
Raised Access Flooring:Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal, 601.5mm Rise.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatalogue Finish: Calcutta GoldButech 10mm Catches System.
Stairs Construction:Stairs Structure 31mm Toughened Glazing,Stainless Steel Hand Rail, Treads Soiled WhiteOak Panel, 30mm x 1200mm x 300mm, Held inPlace by Panel Screw/Tread System 19mmDia.
1 : 50No.08
2.4 GA - Section - AA3 1 : 50No.08
2.4 GA - Section - BB4
No.08
2.0 GA - 3D Interior View7 1 : 25No.08
2.4 GA - Section - AA - GF Ceiling8
No.08
2.4 GA - Section - AA 3D6No.08
2.4 GA - Section - BB 3D9
1 : 50No.08
2.4 GA - Section - Stairs10
DN
UP
DN
UP
North
FD No.2
47 m²Shop Floor
No.1
7 m²Consultation Room
No.2
TD:13
.5m
TD: 2.5m
TD:1
3.5m
TD:13.5m
TD:13.5m
Final Exit Ground Floor Level 0mm
From the back of theShop to the FrontEntrance there is ClearSight, This will Aid in FireDetection and EnsureQuick Detection.
3
No.09
The Stairs is designed to leadDirectly to the Final Exit.
The Stairs is not Part of the EscapeRoute but as it designed in this
manor it can aid in evacuation.
The Consultation Room ismoved from the basement tothe Ground Floor as it is to be
fully assessable. The GlassPartition allows clear view of
the shop and Visa Versa
North
FD No.6
FD No.7
FD No.5
FD No.3
FD No.8
22 m²Workshop
No.4
21 m²Hallway
No.3
3 m²StoreNo.5
5 m²WCNo.6
7 m²Staff Canteen
No.7
6 m²Safe Room
No.8
TD:4.6m
TD:17
.7m
TD:17.7m
TD:17.7m
TD:17
.7m
TD:17m
Finial ExitBasement Level-3000mm
Store is an High RiskArea as it will be leftunattended forlong periods oftime.
The Safe Room is of HighRisk as it is Left Unintended
for Long Periods of time.
The Stairs is notpart of the
Escape Route butis an Option
The Workshop is wherethe most high risk workwill be undertaken This
enclosed with an 60minFire Rating.
3
No.09
1000
4No.09
5No.09
6No.09
7No.09
Gyproc CoreBoard
Gyproc FireStrip (continuous Strip)
Existing Wall Block Work 215mm
Existing Floor Joists 250mm at600mm c/c
Sealant Bead (continuous Strip)Steel Stud 50mm x50mm
Product:12.5mm x 2 Gyproc FireLine BoardFixing: Secured to Steel StudFinish: Plaster Skin 2.5mm
Resistance: 60Min
Service Cavity 150mm.
1313
1313
50150
Gyproc CoreBoardGyproc FireStrip (continuous Strip)
Existing Wall Block Work 215mm
Existing Floor Joists 250mm at600mm c/c
Service Cavity 150mm.
Product:12.5mm x 2 Gyproc FireLine BoardFixing: Secured to Steel StudFinish: Plaster Skin 2.5mm
Resistance: 60Min
Butech Floor Build Up
Sealant Bead (continuous Strip)Steel Stud 50mm x50mm
Product:12.5mm x 2 Gyproc FireLine BoardFixing: Secured to Steel StudFinish: Plaster Skin 2.5mm
Resistance: 60Min
Service Cavity 150mm.
50149
40
1313
1313
50150
Rockwool Cavity Barrier 75mm60min Fire Resistance
Layed ontop of the Joists andSecured
2
Existing Wall Block Work 215mm
Service Cavity 150mm.
Product:12.5mm x 2 GyprocFireLine BoardFixing: Secured to Steel StudFinish: Plaster Skin 2.5mm
Resistance: 60Min
Steel Stud 50mm x50mm
13 13 50 25
30
Exiting Basement Floor
4016
0
35 87
Solid Oak Step 300mm GoingFixing: Secured by Stainless
Steel Screw Fixing
32mm Hardened Glass StringerESG Glass
Butech Floor Build Up
Existing Wall Block Work 215mm
Service Cavity 150mm.
Product:12.5mm x 2 GyprocFireLine Board
Fixing: Secured to Steel StudFinish: Plaster Skin 2.5mm
Resistance: 60Min
Steel Stud 50mm x50mm
1313 50 25
Solid Oak Step 300mm GoingFixing: Secured by StainlessSteel Screw Fixing
32mm Hardened Glass StringerESG Glass
3016
0
FFL
47 m²Shop Floor
No.1
7 m²Consultation Room
No.2
22 m²Workshop
No.4
21 m²Hallway
No.3
3 m²StoreNo.5
5 m²WCNo.6
7 m²Staff Canteen
No.7
6 m²Safe Room
No.8
In Accordance with TGD B, B3Table A2:The Structural Element must bemaintained for 60min.
This forms compartmentation forthe building as Required in B3
This will be Achieved by Liningthe Underside of the Joists withGyproc Fireboard.
Staff Canteen and WC30min Fire Resistance on theCeiling will be given here inaccordance with TGD B, B3Table A21.
This will be Achieved byLining the Underside of theJoists with Gyproc Fireboard.
As the Stairs is in theHallway the Ceiling
requires no FireResistance, As it is
Breached.
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
20/1
0/20
14 1
5:56
:23
3.1 Regulations - TGD B
No.1
07/10/2014
No.09
1 : 50No.09
3.1 Regulations - TGD B - Level 01 1 : 50No.09
3.1 Regulations - TGD B - Level -12
Purpose GroupShop 4(a)Premises used for a retail or wholesale tradeor business (including retail sales byauction, self-selection and over-the-counter wholesale trading, the business oflending books or periodicals for gain andthe business of a barber or hairdresser) andpremises to which the public is invited todeliver or to collect goods in connectionwith their hire, repair or other treatment, orwhere they themselves may carry out suchrepairs or other treatments.
Rooms ScheduleNumber Name Area Occupancy Risk Profile
No.1 Shop Floor 47 m² 10 MinimumNo.2 Consultation Room 7 m² 4 MinimumNo.3 Hallway 21 m² 0 MinimumNo.4 Workshop 22 m² 3 HighNo.5 Store 3 m² 0 HighNo.6 WC 5 m² 1 MinimumNo.7 Staff Canteen 7 m² 3 MediumNo.8 Safe Room 6 m² 0 High
Legend TGD-B:
Travel Distances/ Escape Routes Max 18m
30min Fire Rated Plasterboard Stud WallConstruction. Gyproc Wallboard, ENCLASSIFICATION A.
60min Fire Rated Plasterboard Stud WallConstruction. Gyproc Wallboard, ENCLASSIFICATION A.
30min Fire Resistance Doorset in Accordancewith Tale B1 TGD B, Fitted with fitted withintrumescent strips and smoke seals. Doorsetto be fitted with automatic self-closingdevice which shall be capable of closing thedoor from any angle and against any latchfitted to this door in accordance withAppendix B - B2.
60min Fire Resistance Doorset in Accordancewith Table B1 TGD B, Fitted with fitted withintrumescent strips and smoke seals. Doorsetto be fitted with automatic self-closingdevice which shall be capable of closing thedoor from any angle and against any latchfitted to this door In accordance withAppendix B - B2.
30min Fire Resistant Ceiling in In Accordancewith TGD B, B3 Table A2:Compartmentation.The Structural Elementmust be maintained for 30min.
60min Fire Resistant Ceiling in In Accordancewith TGD B, B3 Table A2:Compartmentation.The Structural Elementmust be maintained for 60min.
General Notes:30min Fire Resistance Ceilings, GyprocFireline, EN CLASSIFICATION A. Plasterboardsecured to Existing Joists.
Emergency escape lighting to comply withtable1.8 TGD - Part B to be designed, installedand certified in accordance with IS3217:2013.
Fire detection system type: L3 to bedesigned, installed and certified inaccordance with IS 3218:2009[2013], i.e.mains powered with battery back-up to beprovided throughout entire building.
The use, siting, inspection and maintenanceof portable fire extinguishers to be designed,installed and certified in accordance with IS291 2002.
All Penetrations in Stud Walls are to be Filledusing FireSeal, Fire Batt – Nullifire B747.
Door ScheduleDoor Number Fire Rating Height Width Level
FD No.1 NA 2000 1000 2.2 GA - Plan - Level 0FD No.2 30Min 2200 1900 2.2 GA - Plan - Level 0FD No.3 60Min 2200 1000 2.2 GA - Plan - Level -1FD No.4 30Min 2200 1000 2.2 GA - Plan - Level -1FD No.5 30Min 2200 1000 2.2 GA - Plan - Level -1FD No.6 30Min 2200 1000 2.2 GA - Plan - Level -1FD No.7 NA 2200 1500 2.2 GA - Plan - Level -1FD No.8 60Min 2200 1000 2.2 GA - Plan - Level -1
1 : 50No.09
3.1 Regulations - Section AA3
1 : 5No.09
3.1 TGD M - Detail No.14
1 : 5No.09
3.1 TGD M - Detail No.25 1 : 5No.09
3.1 TGD M - Detail No.36
1 : 5No.09
3.1 TGD M - Detail No.47
1 : 100No.09
3.1 TGD B - Level 0 - Ceiling Fireproofing8 1 : 100No.09
3.1 TGD B - Level -1 - Ceiling Fireproofing9
In Accordance with TGD B, B3Table A2:The Structural Element must bemaintained for 60min.
This forms compartmentationfor the building as Required inB3
This will be Achieved by Liningthe Underside of the Joists withGyproc Fireboard.
DN
UP
DN
North
47 m²Shop Floor
No.1
7 m²Consultation Room
No.2
Existing Level AccessWidth: 1900mm in Accordancewith TGD-M Part 1.2.4
1900
1200
11761200
1026
.611
00
1400
900Ascension Lifts
Melody 1 Lifting Platform
Platform Lift inCompliance with TGD M -
Part 2.3.4.1.1
1000
Internal Doors in Compliancewith TGD M - Part 1.3.3.2Handles at 900mm above FFLHead Height: 2200mmWidth: 1000mm
Visual Contrasting between:Opening Furniture and SurfaceDoor, Door Frame and Wall.
300
1109.9
1109.9
1109.91000
1000
1000
900
931.
899
7.2
1257.9
1100
Stairs in Accordancewith TGD - K (Handrails)
and TGD M - Part 1.3.4.3and Diagram 14
Clear Width: 1200mmGoing:300mm
Rise160mm
See Illustration No.9+10
Floor finishes throughout thebuilding shall be in
accordance with BS8300:2009 Annex E (Non Slip)
Internal Doors in Compliancewith TGD M - Part 1.3.3.2
Handles at 900mm above FFLHead Height: 2200mm
Width: 1000mm
Visual Contrasting between:Opening Furniture and Surface
Door, Door Frame and Wall.
Stairs in Accordance with TGD -K (Handrails) and TGD M - Part
1.3.4.3 and Diagram 14
Clear Width: 1200mmGoing:300mm
Rise160mm
See Illustration No.9+10
North
22 m²Workshop
No.4
21 m²Hallway
No.3
3 m²StoreNo.5
5 m²WCNo.6
7 m²Staff Canteen
No.7
6 m²Safe Room
No.8
1200
1000
50
1000
2200
1000
300
1000
1000
300
300
1500
1628.51650.0
Floor finishes throughout thebuilding shall be inaccordance with BS8300:2009 Annex E (Non Slip)
1000
3989
.6
600
1242
.5
1802.5
Splash Back Tiling100mm x 100mmPorcelain TilesFixing: Ceramic Grout
1802.5
3000
1800.0
ø 1500
Pull Down Grab Rail atsame Height as HorizontalGrab Rail when at Rest
Vertical Grab Rail
Horizontal Grab Rail
WC with FlatTopped CloseCouple Cistern
Hand Rinse Basin withTap on side closest to WC
Alarm Pull Cord(Two Bangles)
100mm and900mm Above FFL
Non Slip Floor Finish inAccordance with BS
8300:2009 Annex E
500
500
320
150
400
464.5
1000
500mm x 500mm Shelf
Disposal Bin
Sanitary Dispenser CoinSlot 950mm from FFL
800
1200
1028
.4
11501200
1200
Landing in Accordance with:TGD-M Part1.2.4.3
Rise, Going, RunLength, Width inAccordance with TGD- M Part 1.2.4.3
2.2 GA - Plan -Level 0
0
2.2 GA - Plan -Level -1
-3000
900
2706
900
1000
1053
167
275300
170
100012 Steps
2000
1706
6 Steps
Stairs Structure 31mm Toughened Glazing, Stainless Steel Hand Rail, Treads Solid White Oak PaOak, 30mm x 1200mm x 300mm, Held in Place by Panel Screw/Tread System 19mm Dia.
The Stairs Meets all the requirements of TGD K the stairs will meet the requirements set out in TGD M , toAllow Accessto People of All Disability, it will not be an Ambient Disability Stairs but will meet the Highest Standard.
Steps: 18 Rises in Total - Landing: 1000mm1200mm - Rise: 170mm - Going: 300mm - Width 1200mm
410
300
300
1100
730
2500
3000
Vertical Grab Rail
Pull Down Grab Rail at sameHeight as Horizontal Grab Rail
when at Rest
WC with Flat ToppedClose Couple Cistern
Alarm Pull Cord (Two Bangles)100mm and 900mm Above FFL
Hand Rinse Basin with Tap onside closest to WC
Non Slip Floor Finish in Accordancewith BS 8300:2009 Annex E
Vertical grabrails equal distancefrom centre of hand rinse basin
Gyproc MF Suspended Panel System,600mm x 600mm Freshtone panel,Shadow Gap Around Edges.
Lighting Sensor Connected toLight and Extractor Fan
Extractor Fan
1802.51800
2500
2200
410
730
300
300
1100
700
Sanitary Dispenser Coin Slot950mm from FFL
Vertical grabrails equal distancefrom centre of hand rinse basin
Pull Down Grab Rail atsame Height as Horizontal
Grab Rail when at Rest
WC with Flat ToppedClose Couple Cistern
Non Slip Floor Finish in Accordancewith BS 8300:2009 Annex E
Alarm Pull Cord (Two Bangles)100mm and 900mm Above FFL
Vertical Grab Rail
Vertical grabrails equal distancefrom centre of hand rinse basin
Hand Rinse Basinwith Tap on sideclosest to WC
Gyproc MF Suspended Panel System,600mm x 600mm Freshtone panel, ShadowGap Around Edges.
Lighting Sensor Connected toLight and Extractor Fan
Extractor Fan
800
100
4213.44200
900
602.
377
7.7
Small Kitchen UnitOak Veneer MDF Panels
Seating for Staff
2400
1242.5
Splash Back Tiling100mm x 100mmPorcelain TilesFixing: Ceramic Grout
Gyproc MF SuspendedPanel System, 600mm x600mm Freshtone panel,Shadow Gap AroundEdges.
5050
1099
.8
900
1000
1176
1042
.7
1200
1000
Raised Access Floor StepsGoing:300mm
Rise: 165mmIn Accordance with TGD-M Part 1.3.4.3
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
20/1
0/20
14 1
5:58
:38
3.2 Regulations - TGD M
No.1
07/10/2014
No.10
1 : 50No.10
3.2 Regulations - TGD M - Level 01 1 : 50No.10
3.2 Regulations - TGD M - Level -12
1 : 50No.10
3.2 Regulations - TGD M - Kitchen8
1 : 20No.10
3.2 Regulations - TGD M - Toilet3
1 : 50No.10
3.2 Regulations - TGD M - Stairs10 1 : 50No.10
3.2 Regulations - TGD M - Stairs Elevation9
1 : 20No.10
3.2 Regulations - TGD M - Toilet Elevation Front4 1 : 20No.10
3.2 Regulations - TGD M - Toilet Elevation Side5
1 : 50No.10
3.2 Regulations - TGD M - Canteen Elevation Front7
General Notes:The Consultation Room is moved upstairs to allowaccess to people of all disabilities, the ambientsteps and Platform Lift to the Raised Access FloorArea will ensure this.
The Facilities, Toilet and Kitchen is moved downstairs. This area is Staff Only Area.
Section 2 (Access and Use of an Existing Buildingother than Dwellings)of TGD M is relevant to thisBuilding, where possible the Standard set inSection 1 (Access and Use of buildings other thandwellings ) will be Achieved.
Existing Construction has Level Threshold.
Glazed doors (internal & external) to be providedwith permanent manifestations on the glass, withintwo zones, at 900mm and 1500mm above the floorwhich shall visually contrast with the backgroundseen through the glass in all lighting conditions
Switches, outlets and controls within thedevelopment shall be provided in accordancewith diagram 30, TGD M - Part 2.5.7
Signage within the development will be providedwith the international symbol for access on signs tofeatures andfacilities that are accessible such as entrances,routes, sanitary and other facilities in accordancewith TGD M - Part1.6.3
Visual Contrast, The difference in the LRV (lightreflectance values) of surfaces shall be inaccordance with TGD M - Part 1.6.4
Internal doors to be provided in accordance withthe requirements of diagram 10, Table 2 TGD M -Parts 1.3.3. (900mm One Leaf)
Handrails to all stairwells, steps and ramped accessroutes to be provided in accordance with the TGDM - Part 1.1.3
Floor finishes throughout the building shall be inaccordance with BS 8300:2009 Annex E
Legend TGD M:
Unobstructed Circulation Route Min:1000mmTGD-M Part 2.3.3.3
1500mm Turning Circle in Accordance with TGD-M Part 2.3.3.3 (1000Min)
1800mm Turning Circle in Accordance with TGD-M Part 1.4 (Sanitary Facilities) (1500mm Min)
Ascension Platform Lift: Melody 1
Complies with Part M of the BuildingRegulations and meets the requirementsof the Disability Discrimination Act
Application range: People with impairedmobility andWheelchair users. Internal &External Locations
Safe working Load: 250kg (hydraulic scissoroperation)
Maximum travel: 1Metre (1000mm)
Rated speed: 0.06 metres per second
Power supply electrical requirements: 220 /240v~50 /m60 Hz-680mA (max)
Low voltage operating system: 24VDC
Operating temperature range: -10°C to +40°C
Safety: Full platform safe edge which stops thelift should it touch any obstacle in the downdirection only. Fully interlocked upper andlower gates
Emergency lowering facility
Kitchen/Canteen inAccordance with TGD M -Part 1.5 (Diagram 28)See Illustration No.7+8
WC Facilities inAccordance with TGDM - Part 1.4 (Diagram15A)See Illustration No.3+4+5
1 : 50No.10
3.2 Regulations - TGD M - Consultation Room6
Platform Lift inCompliance with TGD
M - Part 2.3.4.1.1
Ascension LiftsMelody 1 Lifting Platform
Platform Lift in Compliancewith TGD M - Part 2.3.4.1.1
Gyproc CoreBoardFixing:Secured to C Channel
and Joist Above
Gyproc FireStrip (continuous Strip)
Existing Wall Block Work 215mm
Existing Floor Joists 250mm at600mm c/c
Sealant Bead (continuous Strip)
Steel Stud 50mm x50mmSecured to C Channel at
Head and Base.
12.5mm x 2 Gyproc FireLine BoardFixing: Secured to Steel Stud
Finish: Plaster Skin 2.5mm
Resistance: 60Min
Service Cavity 150mm.
12.512.5
50150
2x 12.5mm Gyproc FireLineFixing: Secured to Existing JoistsFinish: Plaster Skin 2.5mm
Resistance: 60Min
Existing Floor Joists 250mm at600mm c/c
12.5
356.
2
12.5
150
150 665
12.5mm Gyproc WallboardFixing: Secured to HorizontalBoard Via Steel Angle BracketFinish: 2.5mm Plaster
Vertical Gyproc FurringChannel
12.5mm Gyproc WallBaardFixing: Secured to Gyproc Furring ChannelFinish: 2.5mm Plaster
Gyproc Suspension Rod BracketFixing: Secured to Existing Joist 600mm c/c
Gyproc Suspension ChannelFixing: Top Bracket and Bottom Clip
Gyproc Top Cross RailSecured to Furring ChannelVia Locking Key
9mm MDF Panel White Oak VeneerFixing:Secured to Horizontal BoardVia Steel Angle Bracket
Vertical Gyproc Furring Channel
9mm MDF Panel White Oak VeneerFixing:Secured to Vertical Board ViaSteel Angle Bracket
Gyproc Top Cross RailSecured to Furring ChannelVia Locking Key
Gyproc Suspension ChannelFixing: Top Bracket andBottom Clip
250
Gyproc Furring Channel
138.5
9
9
Vertical Gyproc Furring Channel
10230.
6
300
10
Gyproc Freshtone SuspednedCeiling Panel
600mm x 600mm 10mm ThickFinish: Diamond White Vynal
Gyproc MF CeilingMain Tee SupportFixing: Secured to
Ceiling Via SteelHanger Strip
Gyproc MF CeilingSteel Hanger
Fixing: Secured toExisting Joists
Existing Wall Block Work 215mmExisting Plaster Board and Plaster12.5mm + 2.5mm
Existing Floor Joists 250mmat 600mm c/c
Gyproc MF Ceiling Cross Tee600mm x 600mm Grid System
Shadow Gap Joint
10mm Shadow Gap Bead, Supportingedge of Panel and Cross TeeFixing: Secured to Existing PlasterboardVia Mecanical Fixings
2x 12.5mm Gyproc FireLineFixing: Secured to Existing JoistsFinish: Plaster Skin 2.5mm
Resistance: 60Min
1413.5
138.5 138.5
250
632.
712
.5
12.5
9
9
12.5
368.
7
Vertical Gyproc Furring Channel
9mm MDF Panel White Oak VeneerFixing:Secured to Horizontal Board Via Steel AngleBracket
12.5mm Gyproc WallboardFixing: Secured to Gyproc Furring
Channel Finish: 2.5mm Plaster
Gyproc FurringChannel
9mm MDF Panel White Oak VeneerFixing:Secured to Vertical Board ViaSteel Angle Bracket
Gyproc Suspension ChannelFixing: Top Bracket and Bottom Clip
Gyproc Top Cross RailSecured to FurringChannel Via Locking Key
Gyproc Suspension ChannelBracketFixing: Secured to ExistingJoist 600mm c/c
Existing FloorJoists 250mm at
600mm c/c
2x 12.5mm Gyproc FireLineFixing: Secured to Existing Joists
Finish: Plaster Skin 2.5mm
Resistance: 60Min
Reccesses LuminairePhilips SmartForm LED LightingBBS 415 Family - 4000K
1054.5
The Ceiling Requires a 600mm x 600mm Grid SystemThe Ceiling is a Duel Level Ceiling:
-The Plasterboard at -350 From First Floor Level
-The MDF White Oak Venner at -600 from First Floor Level
Gyproc MF Suspended PanelSystem, 600mm x 600mmFreshtone panel, Shadow GapAround Edges
Gyproc Suspended Ceiling Grid System
- 9mm Plasterboard 9mm- Supported by Gyproc Framing System600mm x 600mm-150mm Bulk Head Upstand-350mm from FFL
Gyproc Suspended Ceiling System
-15mm MDF Oak Veneer Feature-Supported by Gyproc Framing System600mm x 600mm-150mm Bulk Head Upstand-600mm from FFL
1020
0
3000 1200
8400
4243
98.13
°81.87°
Gyproc Suspended Ceiling Grid System-9mm Plasterboard
Gyproc Suspended Ceiling System-15mm MDF Oak Veneer Feature
500 2994 1471
3966
4105
1710
North
4450
5050
1572
1950
3000
4228
148
1803
1793
2990
2255
5030
4430
1930
1552
2520
4416
4667
1783
1783
2980
2234 18
15
Gyproc MF Suspended Panel System.600mm x 600mm Freshtone panelThickness 10mm, Diamond White vinyl-faced
-10mm Shadow Gap Around Edges
Suspended Aluminium Grid System, securedto plasterboard above.Shadow Line Grid
The Hall way that thestairs occupies has nosuspended Ceiling, It hasa plaster finish.
North
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
21/1
0/20
14 0
1:21
:54
4.0 Technology Details -Suspended Ceiling
No.1
07/10/2014
No.11
1 : 5No.11
4.0 Suspended Ceiling - Detail No.11
1 : 5No.11
4.0 Suspended Ceiling - Detail No.22
1 : 5No.11
4.0 Suspended Ceiling - Detail No.34
Specifications:
Wall Build Up:Existing: Wall Build Up 2015mm Brickwork,Lime Based Morter.
New: 215mm Brickwork, 15mm GyprocPlasterbard, 2.5mm Plaster Skim.
Floor Build Up:Existing: 225mm Wooden Joists 500 c/c, Lathand Plaster Finsh.
New: 225mm Wodden Joists 500c/c, Lathand Plaster removed and 12.5mm + 12.5mmGyproc Fireboard replaces it secured toJoists, 2.5mm Plaster Skim.
Suspended Ceiling Build Up:Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF Oak VennerFeature Suspported by Gyproc FramingSystem (GL5)
Gyproc MF Suspened Panel System, 600mm x600mm Freshtone panel, Shadow GapAround Edges.
Partition Build Up:Various Steel Stud System (50mm x 50mm C-Channel) using:
- Gyproc Fireboard,One Sided:Skim 2.5mm Plaste 15mm +15mm 2.5mmPlaster Skim, Shadow gap, (90MIN)
- Gyproc Wallboard, Two sided:Plaster Skim 2.5mm,, 2x12.5mm, 50mm Stud,2x12.5mm, Plaster Skim 2.5mm, (90MIN)
Pilkington LCD FILM Glass 12mm, PartitionSystem. Mild Steel Frame, 100mmx50mm
Internal Doors:New Oak Veneer MDF 3Omin Fire RatedDoors Will be Installed into the StudPartitions.Width: 1000mm meet TGD M and B.
External Doors:Front Door - Solid Oak Double Door HeadHeight: 2200mm Width: 1900mm TripleGlazed Unit, 30min Fire Rated.
Back Door - Veneer Oak MDF Fire RatedDoor. Head Height: 2200mm Width: 1500mm30min Fire Rated.
External Windows:Solid Oak Windows Height: 1500mm Width:1000mm Triple Glazed Unit
Raised Access Flooring:Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Partical Bard Panel withCatolouge Finish: Calacata GoldKingspan Alpha 5 Pedistal, 601.5mm Rise.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatolouge Finish: Calacata GoldButech 10mm Catches System.
Stairs Construction:Stairs Structure 31mm Thoughened Glazing,Stainless Steel Hand Rail, Treads Soild WhiteOak Panel, 30mm x 1200mm x 300mm, Heldin Place by Panel Screw/Tread System 19mmDia.
1 : 100No.11
4.0 Suspended Ceiling - Level 05
1 : 100No.11
4.0 Suspended Ceiling - Level -16
UP
Gyproc MF Ceiling Main Tee SupportFixing: Secured to Ceiling Via SteelHanger Stringer
Gyproc Freshtone SuspendedCeiling Panel 600mm x 600mm10mm Thick Finish: DiamondWhite Vinyl
Gyproc MF Ceiling Steel HangerFixing: Secured to Existing Joists
2x 12.5mm Gyproc FireLine BoardFixing: Secured to Existing Floor Joist
Existing Floor Joists250mm at 600mm c/c
Gyproc MF Ceiling MainTee SupportFixing: Secured to CeilingVia Steel Hanger Stringer
Gyproc FreshtoneSuspended Ceiling Panel
600mm x 600mm 10mmThick Finish: Diamond
White Vinyl
Pilkington Switchblade MirropaneGlass Partition 6mmFixing: Secured at top and bottom
Gyproc FireStrip(continuous Strip)
Pilkington Glazing Gasket
Pilkington Glazing UnitDeflection Head Detail
Fixing: Secured to Rafters
Pilkington SwitchbladeMirropane
Glass Partition 6mmFixing: Secured at top and
bottom by unit and gaskets
Gyproc Steel Stud 50mm x50mmFixing: Secured to C Channel at base
12.5mm Gypson WallBoardFixing: Secured to Gyproc Steel Stud
Kingspan Alpha V Pedistal
Existing Basment Floor Build Up
Sealent Bead andJoining Material
Gypson C ChannelSecured to Exising Floor
Butech 40N Panel System,Thickness 31mm, 600Xmm x600mm Partical Bard Panel withCatolouge Finish: Calacata Gold
Pilkington Glazing UnitFixing: Secured to C Channel Below
673.
3
75
31
12
12.3 12.5
50
160
200
1515
BuTech Expansion Joint Material
Existing Basment Floor Build Up
235.
5
1040
114
50 12.512.512.5 12.5
Joining Material
Sealent Bead
Plaster SkimCoat 2.5mm
2 X 12.5mmGyproc FireLine Board
Fixing: Secured toGyproc Stud Frame
Finish: Plaster Skim
Resistance: 60Min
Gyproc Steel Stud50mm x50mm
Fixing: Secured to CChannel at base
600mm C/C
Gyproc FrameworkC Channel
Fixing: Secured toExisting Floor
Shadow GapBead 10mm
2.5
12.512.52.5
12.512.5
50114
Corner Bead
Gyproc MF Ceiling MainTee Support
Fixing: Secured toCeiling Via SteelHanger Stringer
Gyproc FreshtoneSuspedned Ceiling Panel
600mm x 600mm 10mmThick Finish: Diamond
White Vyna
Gyproc MF CeilingSteel Hanger
Fixing: Secured toExisting Joists
2x 12.5mm GyprocFireLine Board
Fixing: Secured toExisting Floor Joist
Sealent Bead Gyproc FireStrip (continuous Strip)
Existing Floor Joists250mm at 600mm c/c
12.5
12.5
C Channel 50x50mm secured toGyproc CoreBoardDeflection Head Detail
GyprocCoreBoard
Gyproc Steel Stud50mm x50mm
2 X 12.5mmGyproc FireLine BoardFixing: Secured toGyproc Stud FrameFinish: Plaster Skim
Plaster SkimCoat 2.5mm
Butech 15k Panel System,Thickness 12.5mm, 600mm x600mm Calcium Sufile Corewith Catalogue Finish:Calcutta Gold
Butech 10mm Catches System.
6No.12
7No.12
8No.12
12.512.5
2.5
12.512.5
2.5
114
2.5
25
4010
2.512.5
12.5
230.
6
Gyproc FreshtoneSuspedned Ceiling
Panel 600mm x 600mm10mm Thick Finish:
Diamond White Vyna
Gyproc MF CeilingSteel Hanger
Fixing: Secured toExisting Joists
Gyproc MF CeilingMain Tee SupportFixing: Secured to
Ceiling Via SteelHanger Stringer
2x 12.5mm Gyproc WallBoardFixing: Secured to Existing
Floor Joists
2 X 12.5mmGyproc WallBardFixing: Secured to GyprocStud FrameFinish: Plaster Skim
Gyproc Steel Stud50mm x50mm
Plaster Skim Coat2.5mm
Gyproc FireStrip (continuous Strip)
Deflection Head DetailC Channel 60mm x 50mm
Sealent Bead
Existing FloorJoists 250mmat 600mm c/c
Plaster SkimCoat 2.5mm
2 X 12.5mmGyproc WallBard
Fixing: Secured to GyprocStud Frame
Finish: Plaster Skim
Gyproc Steel Stud50mm x50mm
Fixing: Secured to CChannel at base
600mm C/C
Gyproc FrameworkC Channel
Fixing: Secured toExisting Floor
Shadow GapBead 10mm
50
114
50114
Butech 15k Panel System,Thickness 12.5mm, 600mm x600mm Calcium Sufile Corewith Catalogue Finish:Calcutta Gold
Butech 10mm Catches System.
Existing Basment Floor Build Up
Joining Material
Sealent Bead
12.5
10
Corner Bead
2x 12.5mm Gyproc FireLine BoardFixing: Secured to Existing Floor Joist
Existing Floor Joists 250mm at 600mm c/c
Gyproc FireStrip(continuous Strip)
Pilkington Glazing Gasket
Pilkington Glazing UnitDeflection Head DetailFixing: Secured to Existing Wall
Pilkington SwitchbladeMirropaneGlass Partition 6mmFixing: Secured at top andbottom by unit and gasket
1515
50105
150
12.5 12.5 50
77.5
50
Gyproc Steel Stud50mm x50mm
Fixing: Secured to CChannel at base
600mm C/C
Gyproc Steel Stud50mm x50mmFixing: Secured to CChannel at base600mm C/C
Existing BasmentFloor Build Up
Service Cavity
2 X 12.5mmGyproc Fireline Board
Fixing: Secured toGyproc Stud Frame
Finish: Plaster Skim
Plaster SkimCoat 2.5mm
2 X 12.5mmGyproc FireLine BoardFixing: Secured toGyproc Stud FrameFinish: Plaster Skim
Corner Bead
Corner Bead
Gyproc FireStrip(continuous Strip)
Sealent Bead
Gyproc Framework C ChannelFixing: Secured to Existing Floor
1515
50105
150
12.5 12.5 50
77.5
50
Gyproc Steel Stud50mm x50mm
Fixing: Secured to CChannel at base
600mm C/C
Gyproc Steel Stud50mm x50mmFixing: Secured to CChannel at base600mm C/C
Existing BasmentFloor Build Up
Service Cavity
2 X 12.5mmGyproc WallBardFixing: Secured to
Gyproc Stud FrameFinish: Plaster Skim
Plaster SkimCoat 2.5mm
2 X 12.5mmGyproc WallBardFixing: Secured toGyproc Stud FrameFinish: Plaster Skim
Corner Bead
Corner Bead
Gyproc FireStrip(continuous Strip)
Sealent Bead
Gyproc Framework C ChannelFixing: Secured to Existing Floor
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
As indicated
21/1
0/20
14 0
1:22
:02
4.1 Technology Details -Internal Partitons
No.1
07/10/2014
No.12
Specifications:
Wall Build Up:Existing: Wall Build Up 2015mm Brickwork,Lime Based Mortar.
New: 215mm Brickwork, 15mm GyprocPlasterboard, 2.5mm Plaster Skim.
Floor Build Up:Existing: 225mm Wooden Joists 500 c/c, Lathand Plaster Finish.
New: 225mm Wooden Joists 500c/c, Lath andPlaster removed and 12.5mm + 12.5mmGyproc Fibreboard replaces it secured toJoists, 2.5mm Plaster Skim.
Suspended Ceiling Build Up:Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF Oak VeneerFeature Supported by Gyproc Framing System(GL5)
Gyproc MF Suspended Panel System, 600mmx 600mm Freshtone panel, Shadow GapAround Edges.
Partition Build Up:Various Steel Stud System (50mm x 500mm C-Channel) using:
- Gyproc Fireboard,One Sided:Skim 2.5mm Plaster 15mm +15mm 2.5mmPlaster Skim, Shadow gap, (90MIN)
- Gyproc Wallboard, Two sided:Plaster Skim 2.5mm,, 2x12.5mm, 50mm Stud,2x12.5mm, Plaster Skim 2.5mm, (60MIN)
Pilkington LCD FILM Glass 12mm, PartitionSystem. Mild Steel Frame, 100mmx50mm
Internal Doors:New Oak Veneer MDF 3Omin Fire RatedDoors Will be Installed into the Stud Partitions.Width: 1000mm to meet TGD M and B.
External Doors:Front Door - Solid Oak Double Door HeadHeight: 2200mm Width: 1900mm Triple GlazedUnit, 30min Fire Rated.
Back Door - Veneer Oak MDF Fire Rated Door.Head Height: 2200mm Width: 1500mm 30minFire Rated.
External Windows:Solid Oak Windows Height: 1500mm Width:1000mm Triple Glazed Unit
Raised Access Flooring:Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal, 601.5mm Rise.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatalogue Finish: Calcutta GoldButech 10mm Catches System.
Stairs Construction:Stairs Structure 31mm Toughened Glazing,Stainless Steel Hand Rail, Treads Solid WhiteOak Panel, 30mm x 1200mm x 300mm, Held inPlace by Panel Screw/Tread System 19mmDia.
1 : 5No.12
4.1 Internal Partitions - Detail No.41 1 : 5No.12
4.1 Internal Partitions - Detail No.55
1 : 100No.12
4.1 Internal Partitions - Plan 02
1 : 100No.12
4.1 Internal Partitions - Plan -14
1 : 5No.12
4.1 Internal Partitions - Detail No.63
1 : 5No.12
4.1 Internal Partitions - Detail No.76 1 : 5No.12
4.1 Internal Partitions - Detail No.87 1 : 5No.12
4.1 Internal Partitions - Detail No.98
Butech 15k Panel System, Thickness12.5mm, 600mm x 600mm Calcium
Sufile Core with Catalogue Finish:Calcutta Gold
Butech 10mmCatches System.
300
Butech 40N Panel System, Thickness31mm, 600Xmm x 600mm ParticleBard Panel with Catalogue Finish:
Calcutta Gold
Butech 40N Panel System, Thickness31mm, 600Xmm x 600mm Particle BardPanel with Catalogue Finish: Calcutta
Gold
Kingspan Alpha V PedestalFixing:Secured to Existing Ground Floor
20mm MDF Panel White Oak VeneerFixing: Secured to Bottom Angle via
Stainless Steel Fixing
19mm Panel Screw SystemFixing: Secure MDF Panel (White Oak Veneer)
Finish: Polished Stainless Steel
162.
4
162.
5
672.
4
509.
9
347.
4
184.
9
300600
673.
9
12.5mmGyproc Wallboard
Fixing: Secured to Existing WallFinish: Plaster Skim
Plaster Skim Coat 2.5mm
Shadow Gap Bead 10mm
Existing Brickwork Wall215mm
Butech Expansion Joint Material
Butech 40N Panel System, Thickness31mm, 600Xmm x 600mm Particle BardPanel with Catalogue Finish: Calcutta
Gold
Kingspan Alpha V PedestalFixing:Secured to Existing
Ground Floor
Existing Ground Floor
Kingspan Alpha V PedestalPerimeter Head
673.
9
12.5mm x 2 Gyproc FireLineBoard
Fixing: Secured to Steel StudFinish: Plaster Skin 2.5mm
Resistance: 60Min
Plaster Skim Coat 2.5mm
Shadow Gap Bead 10mm
Existing Brickwork Wall215mm
Gyproc FireStrip (continuous Strip)
Butech 40N Panel System, Thickness31mm, 600Xmm x 600mm Particle BardPanel with Catalogue Finish: Calcutta
Gold
Kingspan Alpha V PedestalFixing:Secured to Existing
Ground Floor
Existing Ground Floor
Kingspan Alpha V PedestalPerimeter Head
Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatalogue Finish: Calcutta GoldButech 10mm Catches System.
Ascension Platform Lift: Melody 1
Complies with Part M of the BuildingRegulations and meets the requirementsof the Disability Discrimination Act
Steps Comply with TGD M - Part 1.3.4.3Going : 300mmRise: 162.5mm
Scale
Drawn by
Date
Technical Design andDetailing Year 3
Project 1 : Fitout
Mark Grincell
Dan O'Sullivan / Noel Dunne
1 : 5
21/1
0/20
14 0
1:22
:43
4.2 Technology Details -Raised Access Flooring
No.1
07/10/2014
No.13
Specifications:
Wall Build Up:Existing: Wall Build Up 2015mm Brickwork, LimeBased Mortar.
New: 215mm Brickwork, 15mm GyprocPlasterboard, 2.5mm Plaster Skim.
Floor Build Up:Existing: 225mm Wooden Joists 500 c/c, Lathand Plaster Finish.
New: 225mm Wooden Joists 500c/c, Lath andPlaster removed and 12.5mm + 12.5mmGyproc Fibreboard replaces it secured toJoists, 2.5mm Plaster Skim.
Suspended Ceiling Build Up:Gyproc Suspended Ceiling System,Plasterboard 9mm, 15mm MDF Oak VeneerFeature Supported by Gyproc Framing System(GL5)
Gyproc MF Suspended Panel System, 600mm x600mm Freshtone panel, Shadow Gap AroundEdges.
Partition Build Up:Various Steel Stud System (50mm x 500mm C-Channel) using:
- Gyproc Fireboard,One Sided:Skim 2.5mm Plaster 15mm +15mm 2.5mm PlasterSkim, Shadow gap, (90MIN)
- Gyproc Wallboard, Two sided:Plaster Skim 2.5mm,, 2x12.5mm, 50mm Stud,2x12.5mm, Plaster Skim 2.5mm, (90MIN)
Pilkington LCD FILM Glass 12mm, PartitionSystem. Mild Steel Frame, 100mmx50mm
Internal Doors:New Oak Veneer MDF 3Omin Fire Rated DoorsWill be Installed into the Stud Partitions.Width: 1000mm to meet TGD M and B.
External Doors:Front Door - Solid Oak Double Door HeadHeight: 2200mm Width: 1900mm Triple GlazedUnit, 30min Fire Rated.
Back Door - Veneer Oak MDF Fire Rated Door.Head Height: 2200mm Width: 1500mm 30minFire Rated.
External Windows:Solid Oak Windows Height: 1500mm Width:1000mm Triple Glazed Unit
Raised Access Flooring:Butech 40N Panel System, Thickness 31mm,600Xmm x 600mm Particle Bard Panel withCatalogue Finish: Calcutta GoldKingspan Alpha 5 Pedestal, 601.5mm Rise.
Butech 15k Panel System, Thickness 12.5mm,600mm x 600mm Calcium Sufile Core withCatalogue Finish: Calcutta GoldButech 10mm Catches System.
Stairs Construction:Stairs Structure 31mm Toughened Glazing,Stainless Steel Hand Rail, Treads Solid WhiteOak Panel, 30mm x 1200mm x 300mm, Held inPlace by Panel Screw/Tread System 19mm Dia.
1 : 5No.13
4.2 Raised Access Flooring - Detail No.121
1 : 5No.13
4.2 Raised Access Flooring - Detail No.102 1 : 5No.13
4.2 Raised Access Flooring - Detail No.113
No.13
4.2 Section - Raised Access Floor - Section4