BioMed Central Page 1 of 2 (page number not for citation purposes) Journal of Cardiovascular Magnetic Resonance Open Access Poster presentation Spatio-temporally constrained reconstruction for highly accelerated flow MRI Daniel Giese* 1 , Verena Knobloch 1 , Tobias Schaeffter 2 , Henrik Pedersen 3 and Sebastian Kozerke 1 Address: 1 Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland, 2 Division of Imaging Sciences, King's College London, London, UK and 3 Functional Imaging Unit, Glostrup Hospital, Glostrup, Denmark * Corresponding author Introduction Due to the inherent long scan times, single and multi- directional cine phase-contrast MRI [1] has limited practi- cal value in a clinical setting [2]. Using parallel imaging combined with constrained reconstruction procedures [3], acceleration factors on the order of 4-6 have been shown practicable for flow quantification [4]. Recently, k- t PCA(5) was proposed to further constrain reconstruc- tion. By using principle component analysis (PCA) on the training data, the number of unknowns to be solved for can be reduced thereby permitting acceleration factors excelling those of previous methods. In this work, the k-t PCA method is extended by introducing spatial compart- ment-specific basis sets to improve reconstruction accu- racy at very high undersampling factors (method termed k-t PCA+ hereafter). Purpose Implementation and validation of compartment based spatio-temporally constrained reconstruction of highly undersampled cine phase-contrast MRI. Methods In k-t PCA, the acquired signal in the spatial-temporal fre- quency domain is decomposed into spatially dependent weightings and time-dependent basis functions [5]. This method is extended by defining spatial compartments based on correlation analysis of temporal signal varia- tions. Compartment specific temporal basis sets are sub- sequently used to constrain the dynamic behavior of the reconstructed image. This significantly reduces the number of unknowns in the reconstruction resulting in more accurate results. To validate the proposed algorithm, transverse cine phase- contrast velocity data were obtained at the level of the pul- monary artery in healthy subjects on a 1.5 T Philips Achieva system (Best, NL), (FOV:320 × 260 mm2, matrix:128 × 104, temporal resolution:20 ms). To permit accuracy assessment, fully sampled (reference) data were decimated by a nominal acceleration factor of R, and all reconstruction results were compared to the reference. Three compartments were automatically defined relating to ascending aorta, descending aorta, and remaining pix- els. Results Figure 1 shows flow profiles of the ascending and descending aorta for R = 30 reconstructed with k-t SENSE, k-t PCA and k-t PCA+ along with the result from fully sam- pled data. Using k-t PCA+ excellent reconstruction fidelity is achieved. In contrast to k-t PCA and k-t SENSE, k-t PCA+ does not suffer from temporal filtering effects. The root- mean-square error (RMSE) of reconstruction as a function of acceleration factor is shown in Figure 2. from 13th Annual SCMR Scientific Sessions Phoenix, AZ, USA. 21-24 January 2010 Published: 21 January 2010 Journal of Cardiovascular Magnetic Resonance 2010, 12(Suppl 1):P73 doi:10.1186/1532-429X-12-S1-P73 <supplement> <title> <p>Abstracts of the 13<sup>th </sup>Annual SCMR Scientific Sessions - 2010</p> </title> <note>Meeting abstracts - A single PDF containing all abstracts in this Supplement is available <a href="http://www.biomedcentral.com/content/files/pdf/1532-429X-11-S1-full.pdf">here</a>.</note> <url>http://www.biomedcentral.com/content/files/pdf/1532-429X-11-S1-info</url> </supplement> This abstract is available from: http://jcmr-online.com/content/12/S1/P73 © 2010 Giese et al; licensee BioMed Central Ltd.

Upload: daniel-giese

Post on 06-Jul-2016

215 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Spatio-temporally constrained reconstruction for highly accelerated flow MRI

BioMed Central

Journal of Cardiovascular Magnetic Resonance

ss

Open AccePoster presentationSpatio-temporally constrained reconstruction for highly accelerated flow MRIDaniel Giese*1, Verena Knobloch1, Tobias Schaeffter2, Henrik Pedersen3 and Sebastian Kozerke1

Address: 1Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland, 2Division of Imaging Sciences, King's College London, London, UK and 3Functional Imaging Unit, Glostrup Hospital, Glostrup, Denmark

* Corresponding author

IntroductionDue to the inherent long scan times, single and multi-directional cine phase-contrast MRI [1] has limited practi-cal value in a clinical setting [2]. Using parallel imagingcombined with constrained reconstruction procedures[3], acceleration factors on the order of 4-6 have beenshown practicable for flow quantification [4]. Recently, k-t PCA(5) was proposed to further constrain reconstruc-tion. By using principle component analysis (PCA) on thetraining data, the number of unknowns to be solved forcan be reduced thereby permitting acceleration factorsexcelling those of previous methods. In this work, the k-tPCA method is extended by introducing spatial compart-ment-specific basis sets to improve reconstruction accu-racy at very high undersampling factors (method termedk-t PCA+ hereafter).

PurposeImplementation and validation of compartment basedspatio-temporally constrained reconstruction of highlyundersampled cine phase-contrast MRI.

MethodsIn k-t PCA, the acquired signal in the spatial-temporal fre-quency domain is decomposed into spatially dependentweightings and time-dependent basis functions [5]. Thismethod is extended by defining spatial compartmentsbased on correlation analysis of temporal signal varia-tions. Compartment specific temporal basis sets are sub-

sequently used to constrain the dynamic behavior of thereconstructed image. This significantly reduces thenumber of unknowns in the reconstruction resulting inmore accurate results.

To validate the proposed algorithm, transverse cine phase-contrast velocity data were obtained at the level of the pul-monary artery in healthy subjects on a 1.5 T PhilipsAchieva system (Best, NL), (FOV:320 × 260 mm2,matrix:128 × 104, temporal resolution:20 ms). To permitaccuracy assessment, fully sampled (reference) data weredecimated by a nominal acceleration factor of R, and allreconstruction results were compared to the reference.Three compartments were automatically defined relatingto ascending aorta, descending aorta, and remaining pix-els.

ResultsFigure 1 shows flow profiles of the ascending anddescending aorta for R = 30 reconstructed with k-t SENSE,k-t PCA and k-t PCA+ along with the result from fully sam-pled data. Using k-t PCA+ excellent reconstruction fidelityis achieved. In contrast to k-t PCA and k-t SENSE, k-t PCA+does not suffer from temporal filtering effects. The root-mean-square error (RMSE) of reconstruction as a functionof acceleration factor is shown in Figure 2.

from 13th Annual SCMR Scientific SessionsPhoenix, AZ, USA. 21-24 January 2010

Published: 21 January 2010

Journal of Cardiovascular Magnetic Resonance 2010, 12(Suppl 1):P73 doi:10.1186/1532-429X-12-S1-P73

<supplement> <title> <p>Abstracts of the 13<sup>th </sup>Annual SCMR Scientific Sessions - 2010</p> </title> <note>Meeting abstracts - A single PDF containing all abstracts in this Supplement is available <a href="http://www.biomedcentral.com/content/files/pdf/1532-429X-11-S1-full.pdf">here</a>.</note> <url>http://www.biomedcentral.com/content/files/pdf/1532-429X-11-S1-info</url> </supplement>

This abstract is available from: http://jcmr-online.com/content/12/S1/P73

© 2010 Giese et al; licensee BioMed Central Ltd.

Page 1 of 2(page number not for citation purposes)

Page 2: Spatio-temporally constrained reconstruction for highly accelerated flow MRI

Journal of Cardiovascular Magnetic Resonance 2010, 12(Suppl 1):P73 http://jcmr-online.com/content/12/S1/P73

Publish with BioMed Central and every scientist can read your work free of charge

"BioMed Central will be the most significant development for disseminating the results of biomedical research in our lifetime."

Sir Paul Nurse, Cancer Research UK

Your research papers will be:

available free of charge to the entire biomedical community

peer reviewed and published immediately upon acceptance

cited in PubMed and archived on PubMed Central

yours — you keep the copyright

Submit your manuscript here:http://www.biomedcentral.com/info/publishing_adv.asp

BioMedcentral

ConclusionWe demonstrated that k-t PCA+ can achieve excellentreconstruction accuracy of phase-contrast MRI at veryhigh acceleration factors. Up to 11-fold net scan accelera-tion with very little error in flow profiles relative to thefully sampled reference data has been realized indicatingthe potential of the method to significantly reduce scantimes.

References1. Wigström L, et al.: Magn Reson Med 1999, 41(4):793-9.2. Kilner PJ, et al.: J Cardiovasc Magn Reson 2007, 9(4):723-8.3. Tsao J, et al.: Magn Reson Med 2003, 50(5):1031-42.4. Baltes C, et al.: Magn Reson Med 2005, 54(6):1430-8.5. Pedersen H, et al.: Magn Reson Med 2009.

Flow profiles through the ascending (left) and descending (right) aorta calculated on the fully sampled dataset (green) as well as on a highly undersampled dataset (R = 30 and 6 training profiles) reconstructed by k-t SENSE (black), k-t PCA (blue and k-t PCA+ (red)Figure 1Flow profiles through the ascending (left) and descending (right) aorta calculated on the fully sampled dataset (green) as well as on a highly undersampled dataset (R = 30 and 6 training profiles) reconstructed by k-t SENSE (black), k-t PCA (blue and k-t PCA+ (red).

Flow profile RMSE relative to the fully sampled profiles, plot-ted over the nominal accelerated rate (12 training profiles) for flow profiles through ascending (circles) and descending (crosses) aorta, calculated from undersampled data recon-structed with k-t SENSE (black), k-t PCA (blue) and k-t PCA+ (red)Figure 2Flow profile RMSE relative to the fully sampled pro-files, plotted over the nominal accelerated rate (12 training profiles) for flow profiles through ascending (circles) and descending (crosses) aorta, calculated from undersampled data reconstructed with k-t SENSE (black), k-t PCA (blue) and k-t PCA+ (red).