sew eurodrive movitrac ltp inverters catalog · 500 – 600 v ± 10 %, 3-phase, 50 … 60 hz ± 5 %...

78
Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC ® LTP Edition 03/2009 16798015 / EN Catalog

Upload: others

Post on 18-Nov-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Drive Electronics \ Drive Automation \ System integration \ Services

MOVITRAC® LTP

Edition 03/200916798015 / EN

Catalog

Page 2: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

SEW-EURODRIVE – Driving the world

Page 3: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 3

1 Important Notes................................................................................................. 41.1 Structure of the safety notes ..................................................................... 41.2 Application environment............................................................................ 51.3 Waste disposal.......................................................................................... 5

2 Safety Notes ...................................................................................................... 62.1 Installation and startup .............................................................................. 62.2 Operation and servicing ............................................................................ 6

3 General specifications...................................................................................... 73.1 Input voltage ranges ................................................................................. 73.2 Product designation .................................................................................. 83.3 Output power and current ratings.............................................................. 93.4 Overload capability ................................................................................. 193.5 Protection features.................................................................................. 193.6 Conformance .......................................................................................... 193.7 Environmental ......................................................................................... 203.8 Dimensions ............................................................................................. 213.9 IP20 housing: mounting and dimensions of switch cabinet..................... 233.10 Signal terminal overview ......................................................................... 253.11 Communication Interfaces ...................................................................... 263.12 User interface.......................................................................................... 273.13 Parameter specifications: ....................................................................... 283.14 Selection of Parameter P2-01, Digital Input Function ............................. 35

4 Accessories ..................................................................................................... 424.1 Braking resistors ..................................................................................... 424.2 Line chokes............................................................................................. 494.3 Output chokes......................................................................................... 514.4 DIN rail mounting kit................................................................................ 544.5 Remote keypad option LT BG-00............................................................ 544.6 Cable splitter 1 in and 2 out .................................................................... 564.7 Prefabricated cables with RJ11 connector.............................................. 564.8 Interface adapter option UWS11A .......................................................... 574.9 Interface adapter option LT-W-USB-RJ11 .............................................. 584.10 Second relay output ................................................................................ 594.11 Third relay output .................................................................................... 614.12 Two indicator relay .................................................................................. 634.13 Converter card ........................................................................................ 654.14 Local switchboard ................................................................................... 674.15 Lock ........................................................................................................ 684.16 MC LTP CE, Pocket PC BG LT OWDCE................................................ 684.17 Fieldbus Communication......................................................................... 69

5 Select a motor ................................................................................................. 705.1 Project planning flowchart ....................................................................... 705.2 Inverter → motor combinations ............................................................... 71

6 Index................................................................................................................. 77

Page 4: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

4 Catalog – MOVITRAC® LTP

1 Structure of the safety notes Important Notes

Catalog1 Important Notes1.1 Structure of the safety notes

The safety notes in these operating instructions are structured as follows:

Unless the information in the operating instructions is adhered to, it will be impossible toensure:• Trouble-free operation• Fulfillment of any rights to claim under guarantee

Consequently, read the operating instructions before you start working with theunit!The operating instructions contain important information about servicing. Therefore,keep the operating instructions close to the unit.

Symbol SIGNAL WORD

Nature and source of hazard.Possible consequence(s) if disregarded.• Measure(s) to avoid the hazard.

Symbol Signal Word Meaning Consequences if disregarded

Example:

General hazard

Specific hazard,e.g. electric shock

HAZARD Imminent hazard Severe or fatal injuries

WARNING Possible hazardous situation Severe or fatal injuries

CAUTION Possible hazardous situation Minor injuries

STOP Possible damage to property Damage to the drive system or its environ-ment

NOTE Useful information or tipSimplifies drive system handling

Page 5: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 5

1 Application environmentImportant Notes

1.2 Application environmentThe following applications are forbidden unless measures are expressly taken to makethem possible:• Use in explosion-proof areas• Use in environments with harmful substances:

– Oils– Acids– Gases– Vapors– Dust– Radiated interference– Other harmful environments

• Use subject to mechanical vibration and shock loads in excess of the requirementsin EN 50178

• If the inverter performs safety functions which have to guarantee the protection ofmachinery and people

1.3 Waste disposalPlease follow the current instructions: dispose in accordance with the regulations inforce:• Electronics scrap (printed-circuit boards)• Plastic (housing)• Sheet metal• Copper

Page 6: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

6 Catalog – MOVITRAC® LTP

2 Installation and startup Safety Notes

2 Safety NotesMOVITRAC® LTP drive inverters may not perform safety functions without higher-levelsafety systems.Do not use MOVITRAC® LTP drive inverters for any safety functions in conjunction withhoist applications.

2.1 Installation and startup• Never install damaged products or take them into operation. Please submit a

complaint to the transport company immediately in the event of damage.• Installation, startup and service work on the unit only by trained personnel.

The personnel must be trained in the relevant aspects of accident preventionand must comply with the regulations in force (e.g. EN 60204, VBG 4,DIN VDE 0100/0113/0160).

• Follow the specific instructions during installation and startup of the motor andthe brake!

• Make sure that preventive measures and protection devices correspond to theapplicable regulations (e.g. EN 60204 or EN 50178).Grounding the unit is a necessary protective measure.Overcurrent protection devices are a necessary protective measure.

• The unit meets all requirements for reliable isolation of power and electronicsconnections in accordance with UL508. All connected circuits must also satisfythe requirements for reliable isolation so as to guarantee reliable isolation.

• Take suitable measures to ensure that the connected motor does not start upautomatically when the inverter is switched on. To do this, you can connect binaryinputs DI01 through DI03 to GND.

2.2 Operation and servicing

• Dangerous voltages are present in the output terminals and the cables andmotor terminals connected to them when the unit is switched on. Dangerousvoltages may also be present when the unit is inhibited and the motor at a standstill.

• The unit is not necessarily deenergized when the LEDs and the 7-segmentdisplay are off.

• Safety functions inside the unit or a mechanical blockage may cause the motorto stop. The removal of the source of the malfunction or a reset can result in anautomatic restart of the drive. If, for safety reasons, this is not permissible for thedriven machine, disconnect the unit from the supply system before correcting thefault.

WARNING

Danger of electrical shock. High voltages are present in the terminals and in within thedrive for up to 10 minutes after the electrical supply has been disconnected.Severe or fatal injuries.• Disconnect and isolate the MOVITRAC® LTP from the electrical supply at least 10

minutes before commencing any work on it.

Page 7: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 7

3 Input voltage rangesGeneral specifications

3 General specifications3.1 Input voltage ranges

Depending upon model and power rating, the drives are designed for direct connectionto the following supplies:

MOVITRAC® LTP 240 V units:200 – 240 V ± 10 %, 1-phase* / 3-phase, 50 … 60 Hz ± 5 %

MOVITRAC® LTP 400 V units:380 – 480 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 %

MOVITRAC® LTP 525 V units:480 – 525 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % (Sizes 5 & 6 only)

MOVITRAC® LTP 575 V units:500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 %

Products used with a 3-phase supply are designed for a maximum supply imbalance of3 % between phases. For input supplies which have a supply imbalance greater than3 % (typically the Indian subcontinent and parts of Asia Pacific including China) werecommend that input chokes are used.

NOTE*It is also possible to connect 1-phase MOVITRAC® LTP units to 2-phases of a200 – 240 V, 3-phase mains.

Pi

fkVA

Hz

n

Page 8: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

8 Catalog – MOVITRAC® LTP

3 Product designation General specifications

3.2 Product designation

MC LTP A 0015 2 0 1 1 00 (60 Hz)

60 Hz American version only

Type

00 = Standard IP20 / NEMA 1 housing10 = IP55 / NEMA 12 housing

20 = IP55 / NEMA 12 housing with switch50 = 525 V, standard IP20 / NEMA 1 housing0M = Optional Modbus Firmware

Quadrants 1 = 1Q (without brake chopper)4 = 4Q (with brake chopper)

Connection type 1 = 1-phase3 = 3-phase

Interference suppression on the supply side

0 = class 0A = class AB = class B

Mains voltage

1 = 115 V2 = 200 – 240 V5 = 380 – 480 V6 = 500 – 600 V

Recommended motor power 0015 = 1.5 kW

Version A

Product type MC LTP

Pi

fkVA

Hz

n

Page 9: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 9

3 Output power and current ratingsGeneral specifications

3.3 Output power and current ratings3.3.1 1-phase system AC 230 V for 3-phase AC 230 V motors (Size 1)

Standard MOVITRAC® MC LTP A... 0004 2B1 1 -00 0008 2B1 1 -00 0015 2B1 1 -00

Part number 8286914 8286922 8299226

IP55 / NEMA 12 housing MOVITRAC® MC LTP A... 0004 2B1 1 -10 0008 2B1 1 -10 0015 2B1 1 -10

Part number 8291756 8291764 8299234

IP55 / NEMA 12 with switch MOVITRAC® MC LTP A... 0004 2B1 1 -20 0008 2B1 1 -20 0015 2B1 1 -20

Part number 8291799 8291802 8299242

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 1-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 10 16 20

Nominal input current [A] 6.7 12.5 19.3

OUTPUT

Recommended motor power [kW] 0.37 0.75 1.5

[hp] 0.5 1 2

Output voltage [V] 3 × 20 – 250 V

Output current [A] 2.3 4.3 7

Motor cable size Cu 75C [mm2] 1.5

[AWG] 16

Max motor cable length Shielded[m]

25

Unshielded 40

GENERAL

Heat loss at nominal output power [W] 11 22 45

Minimal braking resistor value [Ω] – – –

Pi

fkVA

Hz

n

Page 10: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

10 Catalog – MOVITRAC® LTP

3 Output power and current ratings General specifications

3.3.2 1-phase system AC 230 V for 3-phase AC 230 V motors (Size 2)

Standard MOVITRAC® MC LTP A... 0015 2B1 4 -00 0022 2B1 4 -00

Part number 8286949 8286957

IP55 / NEMA 12 housing MOVITRAC® MC LTP A... 0015 2B1 4 -10 0022 2B1 4 -10

Part number 8291772 8291780

IP55 / NEMA 12 with switch MOVITRAC® MC LTP A... 0015 2B1 4 -20 0022 2B1 4 -20

Part number 8294925 8294933

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 1-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 20 32

Nominal input current [A] 19.3 28.8

OUTPUT

Recommended motor power [kW] 1.5 2.2

[hp] 2 3

Output voltage [V] 3 × 20 – 250 V

Output current [A] 7 10.5

Motor cable size Cu 75C [mm2] 1.5

[AWG] 16

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 45 66

Minimal braking resistor value [Ω] 33 22

Pi

fkVA

Hz

n

Page 11: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 11

3 Output power and current ratingsGeneral specifications

3.3.3 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 2)

Standard MOVITRAC® MC LTP A... 0015 2B3 4 -00 0022 2B3 4 -00

Part number 8299250 8299269

IP55 / NEMA 12 housing MOVITRAC® MC LTP A... 0015 2B3 4 -10 0022 2B3 4 -10

Part number 8299277 8299285

IP55 / NEMA 12 with switch MOVITRAC® MC LTP A... 0015 2B3 4 -20 0022 2B3 4 -20

Part number 8299293 8299307

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 20 32

Nominal input current [A] 19.3 28.8

OUTPUT

Recommended motor power [kW] 1.5 2.2

[hp] 2 3

Output voltage [V] 3 × 20 – 250 V

Output current [A] 7 10.5

Motor cable size Cu 75C [mm2] 1.5

[AWG] 16

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 45 66

Minimal braking resistor value [Ω] 33 22

Pi

fkVA

Hz

n

Page 12: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

12 Catalog – MOVITRAC® LTP

3 Output power and current ratings General specifications

3.3.4 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 3)

3.3.5 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 4)

MOVITRAC® MC LTP A... 0030 2A3 4 -00 0040 2A3 4 -00 0055 2A3 4 -00

Part number 8286965 8286973 8286981

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 32 50

Nominal input current [A] 16.1 17.3 25

OUTPUT

Recommended motor power [kW] 3 4 5.5

[hp] 4 5 7.5

Output voltage [V] 3 × 20 – 250 V

Output current [A] 14 18 24

Motor cable size Cu 75C [mm2] 2.5 4

[AWG] 12 10

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 90 120 165

Minimal braking resistor value [Ω] 15

MOVITRAC® MC LTP A... 0075 2A3 4 -00 0110 2A3 4 -00 0150 2A3 4 -00 0185 2A3 4 -00

Part number 8287007 8287015 8287023 8287031

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 50 63 80

Nominal input current [A] 46.6 54.1 69.6 76.9

OUTPUT

Recommended motor power [kW] 7.5 11 15 18.5

[hp] 10 15 20 25

Output voltage [V] 3 × 20 – 250 V

Output current [A] 39 46 61 72

Motor cable size Cu 75C [mm2] 10 16

[AWG] 6 4

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 225 330 450 555

Minimal braking resistor value [Ω] 6

Pi

fkVA

Hz

n

Page 13: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 13

3 Output power and current ratingsGeneral specifications

3.3.6 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 5)

3.3.7 3-phase system AC 230 V for 3-phase AC 230 V motors (Size 6)

MOVITRAC® MC LTP A... 0220 2A3 4 -00 0300 2A3 4 -00 0370 2A3 4 -00 0450 2A3 4 -00

Part number 8287058 8287066 8287074 8287082

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 160 200 250 – 300

Nominal input current [A] 92.3 116.9 140.2 176.5

OUTPUT

Recommended motor power [kW] 22 30 37 45

[hp] 30 40 50 60

Output voltage [V] 3 × 20 – 250 V

Output current [A] 90 110 150 180

Motor cable size Cu 75C [mm2] 25 35 55 70

[AWG] 4 3 2 / 0 3 / 0

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 660 900 1110 1350

Minimal braking resistor value [Ω] 3

MOVITRAC® MC LTP A... MC LTP A... 0550 2A3 4 -00 0750 2A3 4 -00 0900 2A3 4 -00

Part number 8287090 8287104 8287112

INPUT

Supply voltage [Vmains] 200 – 240 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 315 – 350 400 450 – 500

Nominal input current [A] 217.2 255.7 302.4

OUTPUT

Recommended motor power [kW] 55 75 90

[hp] 75 100 120

Output voltage [V] 3 × 20 – 250 V

Output current [A] 202 240 300

Motor cable size Cu 75C [mm2] 90 120 170

[AWG] 3 / 0 4 / 0

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 1650 2250 2700

Minimal braking resistor value [Ω] 3

Pi

fkVA

Hz

n

Page 14: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

14 Catalog – MOVITRAC® LTP

3 Output power and current ratings General specifications

3.3.8 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 2)

3.3.9 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 3)

Standard MOVITRAC® MC LTP A... 0008 5A3 4 -00 0015 5A3 4 -00 0022 5A3 4 -00 0040 5A3 4 -00

Part number 8287147 8287155 8287163 8287171

IP55 / NEMA 12 housing MOVITRAC® MC LTP A... 0008 5A3 4 -10 0015 5A3 4 -10 0022 5A3 4 -10 0040 5A3 4 -10

Part number 8292582 8292590 8292604 8292612

IP55 / NEMA 12 with switch MOVITRAC®

MC LTP A... 0008 5A3 4 -20 0015 5A3 4 -20 0022 5A3 4 -20 0040 5A3 4 -20

Part number 8292620 8292639 8292647 8292655

INPUT

Supply voltage [Vmains] 380 – 480 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 6 – 10 10 16 20

Nominal input current [A] 2.9 5.4 7.6 12.4

OUTPUT

Recommended motor power [kW] 0.75 1.5 2.2 4

[hp] 1 2 3 5

Output voltage [V] 3 × 20 – 480 V

Output current [A] 2.2 4.1 5.8 9.5

Motor cable size Cu 75C [mm2] 1.0 1.5

[AWG] 17 16

Max. motor cable length Shielded[m]

50 100

Unshielded 75 150

GENERAL

Heat loss at nominal output power [W] 22 45 66 120

Minimal braking resistor value [Ω] 47 33

MOVITRAC® MC LTP A... 0055 5A3 4 -00 0075 5A3 4 -00 0110 5A3 4 -00 0150 5A3 4 -00

Part number 8287198 8287201 8287228 8287236

INPUT

Supply voltage [Vmains] 380 – 480 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 32 50

Nominal input current [A] 16.1 17.3 25 32.9

OUTPUT

Recommended motor power [kW] 5.5 7.5 11 15

[hp] 7.5 10 15 20

Output voltage [V] 3 × 20 – 480 V

Output current [A] 14 18 24 30

Motor cable size Cu 75C [mm2] 2.5 4.0 6.0

[AWG] 12 10 8

Max motor cable length (unshielded)

Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 165 225 330 450

Minimal braking resistor value [Ω] 22

Pi

fkVA

Hz

n

Page 15: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 15

3 Output power and current ratingsGeneral specifications

3.3.10 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 4)

3.3.11 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 5)

MOVITRAC® MC LTP A... 0185 5A3 4 - 00 0220 5A3 4 -00 0300 5A3 4 -00 0370 5A3 4 -00

Part number 8287244 8287252 8287260 8287279

INPUT

Supply voltage [Vmains] 380 – 480 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 80 80 – 100 100 125

Nominal input current [A] 46.6 54.1 69.6 76.9

OUTPUT

Recommended motor power [kW] 18.5 22 30 37

[hp] 25 30 40 50

Output voltage [V] 3 × 20 – 480 V

Output current [A] 39 46 61 72

Motor cable size Cu 75C [mm2] 10 16

[AWG] 6 4

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 555 660 900 1110

Minimal braking resistor value [Ω] 12

MOVITRAC® MC LTP A... 0450 5A3 4 -00 0550 5A3 4 -00 0750 5A4 4 -00 0900 5A3 4 -00

Part number 8287287 8287295 8287309 8287317

INPUT

Supply voltage [Vmains] 380 – 480 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 160 200 250 – 300

Nominal input current [A] 92.3 116.9 150.2 176.5

OUTPUT

Recommended motor power [kW] 45 55 75 90

[hp] 60 75 100 120

Output voltage [V] 3 × 20 – 480 V

Output current [A] 90 110 150 180

Motor cable size Cu 75C [mm2] 25 55 70

[AWG] 4 2 / 0 3 / 0

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 1350 1650 2250 2700

Minimal braking resistor value [Ω] 6

Pi

fkVA

Hz

n

Page 16: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

16 Catalog – MOVITRAC® LTP

3 Output power and current ratings General specifications

3.3.12 3-phase system AC 400 V for 3-phase AC 400 V motors (Size 6)

3.3.13 3-phase system AC 575 V for 3-phase AC 575 V motors (Size 2)

MOVITRAC® MC LTP A... 1100 5A3 4 -00 1320 5A3 4 -00 1600 5A3 4 -00

Part number 8287325 8287333 8287341

INPUT

Supply voltage [Vmains] 380 – 480 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 315 – 350 400 450 – 500

Nominal input current [A] 217.2 255.7 302.4

OUTPUT

Recommended motor power [kW] 110 132 160

[hp] 150 175 200

Output voltage [V] 3 × 20 – 480 V

Output current [A] 202 240 300

Motor cable size Cu 75C [mm2] 90 120 170

[AWG] 4 / 0 5 / 0 6 / 0

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 3300 3960 4800

Minimal braking resistor value [Ω] 6

Standard MOVITRAC® MC LTP A... 0008 603 4 -00 0015 603 4 -00 0022 603 4 -00 0037 603 4 -00 0055 603 4 -00

Part number 8286833 8286841 8286868 8286876 8286884

IP55 / NEMA 12 housing MOVITRAC®

MC LTP A... 0008 603 4 -10 0015 603 4 -10 0022 603 4 -10 0037 603 4 -10 0055 603 4 -10

Part number 8290814 8290822 8290830 8290849 8290857

IP55 / NEMA 12 with switch MOVITRAC®

MC LTP A... 0008 603 4 -20 0015 603 4 -20 0022 603 4 -20 0037 603 4 -20 0055 603 4 -20

Part number 8290865 8290873 8290881 8290903 8290911

INPUT

Supply voltage [Vmains] 500 – 600 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 6 10 20

Nominal input current [A] 2.2 4.1 6.1 7.6 11.7

OUTPUT

Recommended motor power [kW] 0.75 1.5 2.2 3.7 5.5

[hp] 1 2 3 5 7.5

Output voltage [V] 3 × 20 – 575 V

Output current [A] 1.7 3.1 4.1 6.1 9

Motor cable size Cu 75C [mm2] 1.0 1.5

[AWG] 17 16

Max motor cable length

Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power

[W] 22 45 66 111 165

Minimal braking resistor value [Ω] 47

Pi

fkVA

Hz

n

Page 17: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 17

3 Output power and current ratingsGeneral specifications

3.3.14 3-phase system AC 575 V for 3-phase AC 575 V motors (Size 3)

3.3.15 3-phase system AC 575 V for 3-phase AC 575 V motors (Size 4)

MOVITRAC® MC LTP A... 0075 603 4 -00 0110 603 4 -00 0150 603 4 -00

Part number 8286892 8286906 8298139

INPUT

Supply voltage [Vmains] 500 – 600 V ±10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 25 32

Nominal input current [A] 16.1 17.3 25.1

OUTPUT

Recommended motor power [kW] 7.5 11 15

[hp] 10 15 20

Output voltage [V] 3 × 20 – 575 V

Output current [A] 14 18 24

Motor cable size Cu 75C [mm2] 2.5 4

[AWG] 14 10

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 185 330 450

Minimal braking resistor value [Ω] 22

MOVITRAC® MC LTP A... 0220 603 4 -00 0300 603 4 -00 0450 603 4 -00

Part number 8298149 8298157 8298165

INPUT

Supply voltage [Vmains] 500 – 600 V ±10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 50 63 80

Nominal input current [A] 46.6 54.1 69.6

OUTPUT

Recommended motor power [kW] 22 30 45

[hp] 30 40 60

Output voltage [V] 3 × 20 – 575 V

Output current [A] 39 46 62

Motor cable size Cu 75C [mm2] 10 16

[AWG] 6 4

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 660 900 1350

Minimal braking resistor value [Ω] 12

Pi

fkVA

Hz

n

Page 18: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

18 Catalog – MOVITRAC® LTP

3 Output power and current ratings General specifications

3.3.16 3-phase system AC 525 V for 3-phase AC 500 V motors (Size 5)

3.3.17 3-phase system AC 525 V for 3-phase AC 500 V motors (Size 6)

MOVITRAC® MC LTP A... 0550 603 4 -50 0750 603 4 -50 0900 603 4 -50

Part number 8299315 8299323 8299331

INPUT

Supply voltage [Vmains] 480 – 525 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 125 160 200

Nominal input current [A] 92.3 116.9 150.2

OUTPUT

Recommended motor power [kW] 55 75 90

[hp] 75 100 120

Output voltage [V] 3 × 20 – 525 V

Output current [A] 90 110 150

Motor cable size Cu 75C [mm2] 35 50 70

[AWG] 4 2 / 0 3 / 0

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 1650 2250 2770

Minimal braking resistor value [Ω] 6

MOVITRAC® MC LTP A... 1320 603 4 -50 1600 603 4 -50 2000 603 4 -50

Part number 8299358 8299366 8299374

INPUT

Supply voltage [Vmains] 480 – 525 V ± 10 %, 3-phase

Supply frequency [fmains] 50 / 60 Hz

Supply fuse rating [A] 300 400

Nominal input current [A] 217.2 255.7 290

OUTPUT

Recommended motor power [kW] 132 160 200

[hp] 175 210 250

Output voltage [V] 3 × 20 – 525 V

Output current [A] 202 240 270

Motor cable size Cu 75C [mm2] 90 120 170

[AWG] 5 / 0 6 / 0

Max motor cable length Shielded[m]

100

Unshielded 150

GENERAL

Heat loss at nominal output power [W] 3960 4800 6000

Minimal braking resistor value [Ω] 6

Pi

fkVA

Hz

n

Page 19: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 19

3 Overload capabilityGeneral specifications

3.4 Overload capabilityAll MOVITRAC® LTP units have a possible overload of:• 150 % for 60 seconds• 175 % for 2 seconds

3.5 Protection features• Output short-circuit, phase-to-phase, phase-to-ground• Output over-current

– Trip set at 175 % of rated drive current.• Overload protection

– Drive delivers 150 % of rated motor current for 60 seconds.• Braking transistor protected against short-circuit.• Braking resistor overload (when enabled)• Over-voltage trip

– Set at 123 % of drive maximum rated supply voltage.• Under-voltage trip• Over temperature trip• Under temperature trip

– Drive will trip if enabled below –10 °C• Supply phase imbalance

– A running drive will trip if there is a supply imbalance of > 3 % persisting formore than 30 seconds.

• Supply phase loss– A running drive will trip if one phase of a 3-phase supply is lost for more than

15 seconds.

3.6 ConformanceAll products conform to the following international standards:• UL 508C Power conversion equipment• EN 61000-6 / -2, -3, -4 Generic immunity / Emission standards (EMC)• Enclosure protection level according to NEMA 250, EN 60529• Flammability rating according to UL 94• cUL Power conversion equipment, certified for Canada

Pi

fkVA

Hz

n

Page 20: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

20 Catalog – MOVITRAC® LTP

3 Environmental General specifications

3.7 Environmental

Operational ambient temperature range 0 – 50 °C at default PWM frequency (IP20)0 – 40 °C at default PWM frequency (IP55, NEMA 12k)

Maximum ambient temperature derating 4 % / °C up to 55 °C for IP20 drives4 % / °C up to 45 °C for IP55 drives

Storage ambient temperature range –40 – +60 °C

Maximum altitude for rated operation 1000 m

Derating above 1000 m 1 % / 100 m to max. 2000 m

Maximum relative humidity 95 % (non-condensing)

Protection rating cabinet drive IP20

Protection rating high enclosure drive IP55, NEMA 12 k

Pi

fkVA

Hz

n

Page 21: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 21

3 DimensionsGeneral specifications

3.8 DimensionsMOVITRAC® LTP is available in 2 housing versions:• Standard IP20 / NEMA 1 housing for use in switch cabinets• IP55 / NEMA 12 version for size 1 and size 2 drivesThe IP55 / NEMA 12 housing is protected against moisture and dust. Therefore, thedrives can be operated indoors under harsh conditions. Electronically, the drives areidentical and the only differences are the dimensions of the housing and the weight.

3.8.1 Dimensions of the IP20 / NEMA 1 housing

54769AXX 54781AXX 54770AXX

A

B

C

a

c

d

b b

c

Dimension Size 1 Size 2 Size 3 Size 4 Size 5 Size 61)

Height (A) [mm] 155 260 260 520 1045 1100

[in] 6.10 10.20 10.20 20.47 41.14 43.31

Width (B) [mm] 80 100 171 340 340 340

[in] 3.15 3.94 6.73 13.39 13.39 13.39

Depth (C) [mm] 130 175 175 220 220 330

[in] 5.12 6.89 6.89 8.66 8.66 12.99

Weight [kg] 1.1 2.6 5.3 28 68 Unit = 55Choke = 27

[lb] 2.43 5.73 11.68 61.73 149.91 149.91

a [mm] 72 92 163 320 320 320

[in] 2.84 3.62 6.42 12.6 12.6 12.6

b [mm] 4 4 4 9.5 9.5 9.5

[in] 0.16 0.16 0.16 0.37 0.37 0.37

c [mm] 25 25 25 50 50 50

[in] 0.98 0.98 0.98 1.97 1.97 1.97

d [mm] 105 210 210 420 945 945

[in] 4.13 8.27 8.27 16.54 37.21 37.21

Power terminal torque settings

[Nm] 1 1 1 4 8 8

[lb.in] 8.85 8.85 8.85 35.4 70.8 70.8

Fixings 2 × M4 2 × M4 4 × M4 4 × M8 4 × M8 4 × M8

1) Size 6 comes with an external line choke

Pi

fkVA

Hz

n

Page 22: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

22 Catalog – MOVITRAC® LTP

3 Dimensions General specifications

3.8.2 Dimensions of the IP55 / NEMA 12 housing (LTP xxx –10 and –20)

60198AXX 60200AXX 60199AXX 60497AXX

A

BC

c

d

b

c

a b

XX Y

Z

Dimension Size 1 Size 2

Height (A) [mm] 200 310

[in] 7.9 12.2

Width (B) [mm] 140 165

[in] 5.5 6.5

Depth (C) [mm] 165 176

[in] 6.5 6.9

Weight [kg] 2.3 4.5

[lb] 5.1 9.9

a [mm] 128 153

[in] 5 6

b [mm] 6 6

[in] 0.23 0.23

c [mm] 25 25

[in] 0.98 0.98

d [mm] 142 252

[in] 5.6 9.9

X [mm] 22 25

[in] 0.87 0.98

Y1) [mm] 22 22

[in] 0.87 0.87

Z1) [mm] 17 17

[in] 0.67 0.67

Power terminal torque settings

[Nm] 1 1

[lb.in] 8.85 8.85

Control terminal torque settings

[Nm] 0.5 0.5

[lb.in] 4.43 4.43

Fixings 2 × M4 4 × M4

1) Glands Y and Z are flip out glands.

Pi

fkVA

Hz

n

Page 23: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 23

3 IP20 housing: mounting and dimensions of switch cabinetGeneral specifications

3.9 IP20 housing: mounting and dimensions of switch cabinetFor applications that require a higher IP rating than the IP20 offered by the standarddrive, the drive must be mounted in a switch cabinet. The following guidelines should beobserved for these applications:• The switch cabinet should be made from a thermally conductive material, unless

forced ventilation is used.• When a vented switch cabinet is used, there should be venting above and below the

drive to ensure good air circulation. Air should be drawn in below the drive andexpelled above the drive.

• If the external environment contains contamination particles (e.g. dust), a suitableparticle filter should be fitted to the vents and forced ventilation implemented. Thefilter must be serviced and cleaned appropriately.

• High moisture, salt or chemical content environments should use a suitably sealed(non-vented) switch cabinet.

3.9.1 Dimensions of non-vented metal switch cabinet

Drive power rating

Sealed switch cabinet

A B C D

[mm] [in] [mm] [in] [mm] [in] [mm] [in]

Size 1 0.75 kW 230 V 300 11.81 250 9.84 200 7.87 50 1.97

Size 1 1.5 kW 230 V 400 15.75 300 11.81 250 9.84 75 2.95

Size 2 1.5 kW 230 V0.75 kW, 1.5 kW, 2.2 kW 400 V2.2 kW 400 V

400 15.75 300 11.81 300 11.81 60 2.36

Size 2 2.2 kW 230 V4.0 kW 400 V5.5 kW 575 V

600 23.62 450 17.72 300 11.81 100 3.94

54784AXXFigure 1: Switch cabinet

A

D

D

C

B

Pi

fkVA

Hz

n

Page 24: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

24 Catalog – MOVITRAC® LTP

3 IP20 housing: mounting and dimensions of switch cabinet General specifications

3.9.2 Dimensions of vented switch cabinet

3.9.3 Dimensions of force-vented switch cabinet

Drive power rating

Vented switch cabinet

A B C D

[mm] [in] [mm] [in] [mm] [in] [mm] [in]

Size 1 1.5 kW 400 15.75 300 11.81 150 5.91 75 2.95

Size 2 5.5 kW 600 23.62 400 15.75 250 9.84 100 3.94

Size 3 15 kW 800 31.50 600 23.62 300 11.81 150 5.91

Size 4 22 kW 1000 39.37 600 23.62 300 11.81 200 7.87

Size 4 37 kW – – – – – – – –

Size 5 90 kW – – – – – – – –

Size 6 160 kW – – – – – – – –

Drive power rating

Force-vented switch cabinet (with fan)

A B C D

Air Flow[mm] [in] [mm] [in] [mm] [in] [mm] [in]

Size 1 1.5 kW 275 10.83 150 5.91 150 5.91 50 1.97 > 15 m3 / h

Size 2 5.5 kW 320 12.60 200 7.87 250 9.84 75 2.95 > 45 m3 / h

Size 3 15 kW 400 15.75 250 9.84 250 9.84 100 3.94 > 80 m3 / h

Size 4 22 kW 800 31.50 500 19.69 300 11.81 130 5.12 > 300 m3 / h

Size 4 37 kW 800 31.50 500 19.69 300 11.81 130 5.12 > 300 m3 / h

Size 5 90 kW 1500 59.06 600 23.62 400 15.75 200 7.87 > 900 m3 / h

Size 6 160 kW 1600 62.99 600 23.62 400 15.75 250 9.84 > 1000 m3 / h

Pi

fkVA

Hz

n

Page 25: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 25

3 Signal terminal overviewGeneral specifications

3.10 Signal terminal overview

The User Control terminals are available via an 11-way pluggable connector. All termi-nals are galvanically isolated, allowing direct connection to other equipment.

The functionality of the inputs and outputs is user configurable. All operating modes areset up via the parameter set.Up to 100 mA can be sourced from the User +24 V output and up to 20 mA from theanalog output.

The signal terminal block has the following signal connections:

STOP!Danger of damage to the MOVITRAC® LTP unit.Do not connect mains supply voltages to any terminals other than the user relay output.Doing so will result in permanent damage to the unit.The user relay output can handle up to AC 250 V. All other inputs only withstandDC 30 V without damage.

IP20 and IP55 IP55 with switch option

64485AEN 64608AEN

+24 V

DI 1

DI 2

DI 3

+10 V

AI/D

I

0 V

AO

/DO

0 V

Rela

y c

on

tact

Rela

y c

om

mon

1 2 3 4 5 6 7 8 9 10 11

+24 V

DI 1

DI 2

DI 3

+10 V

AI/D

I

0 V

AO

/DO

0 V

Rela

y c

on

tact

Rela

y c

om

mon

1 2 3 4 5 6 7 8 9 10 11

FW

D

RE

V

Terminal no.

Signal Connection Description

1 +24 V +24 V ref out Ref. to activate DI1 – DI3 (100 mA max.)

2 DI1 Digital input 1 Positive logic"Logic 1" input voltage range: DC 8 – 30 V"Logic 0" input voltage range: DC 0 – 8 V3 DI2 / DO2 Digital input 2 /

Digital output 2

4 DI3 / AI2 Digital input 3 /Analog input 2

Positive logic (P2-33)"Logic 1" input voltage range: DC 8 – 30 V"Logic 0" input voltage range: DC 0 – 8 V0 – 10 V, 0 – 20 mA, 4 – 20 mA

5 +10 V +10 V ref out 24 V ref for analog input(pot supply +, 100 mA max., 1 kΩ min.)

6 AI / DI Analog input (12 bit)Digital input 4

0 – 10 V, –10 – +10 V, 0 – 24 V, –24 – +24 V"Logic 1" input voltage range: DC 8 – 30 V (P2-30)

7 0 V 0 V common 0 V ref for analog input (pot supply –)

8 AO / DO Analog output (8 bit)Digital output

0 – 10 V, 4 – 20 mA analog24 V, 20 mA digital (P2-36)

9 0 V 0 V common 0 V ref for analog output

10 Relay contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)

11 Relay common Relay common

Pi

fkVA

Hz

n

Page 26: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

26 Catalog – MOVITRAC® LTP

3 Communication Interfaces General specifications

3.10.1 Key information on the control terminal

• Maximum input voltage on any terminal: DC 30 V• All outputs are short-circuit proof• Recommended potentiometer resistance: 1 k Ω• Digital input response time: < 8 ms • Bipolar analog input response time: < 16 ms. Resolution ±12-bit (0.025 %)• Second analog input response time: < 16ms. Resolution +11-bit (0.05 %)• Analog / digital output response time: < 16ms. Resolution 8-bit (0.25 %)

3.11 Communication Interfaces3.11.1 RJ11 Communication socket

The RJ11 communication socket can be used to set up RS-485 communication to thePC via UWS11A.With MOVITRAC® LTP units it is possible to use this RJ11 connector to set up aMODBUS communication network.

The internal bus works with 115 k Baud (bps). It can be used for drive-to-drive commu-nication. In this case, up to 63 drives can communicate.The MODBUS RTU works between 9.6 and 115 k Baud (bps). It can be used to com-municate directly with an external PLC or with a fieldbus gateway. In this case, up to 63drives can be controlled via bus communication.

57406AXX

[1] RS-485– / MODBUS 1)

1) The bit format is fixed as: 1 start bit, 8 data bits, 1 stop bit, no parity

[2] RS-485+ / internal bus 1)

[3] RS-485– / internal bus 1)

[4] +24 V

[5] 0 V

[6] RS-485+ / MODBUS 1)

[2]

[3]

[4]

[5]

[6]

[1]

Pi

fkVA

Hz

n

Page 27: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 27

3 User interfaceGeneral specifications

3.11.2 Infra-red/IrDA interface

The optical interface, which is located next to the RJ11 connector, is mainly used forcommissioning and monitoring the drive with a pocket PC. When LT shell CE is installedthe pocket PC can be used to commission the drive and monitor the current status ofthe drive.Additionally the infra-red interface can be used to set up a master slave network. How-ever the maximum number of slaves is limited to 2.

3.12 User interface3.12.1 Keypad

Each MOVITRAC® LTP has an integrated keypad as standard, allowing drive operationand set up without any additional equipment.

The keypad consists of 5 keys with the following functions:

The Start / Stop buttons on the keypad are disabled when the parameters have theirfactory default settings. To enable the operation of the <start> / <stop> buttons on thekeypad, set P-12 to 1 or 2 (see chapter "Standard parameters" on page 28).

The Navigate key alone is used to gain access to the parameter edit menu. Pressingand holding this key (> 1 second) allows the user to toggle between the parameter editmenu and the real time display (where the drive operating status / running speed isdisplayed). By pressing this key (< 1 second) the user is able to toggle between theoperating speed and operating current during drive operation.

Start / Run Enable running of motor

Stop / Reset Stop motor / Reset trip

Navigate Press and release to display A / Hz / rpmPress and hold to enter / exit parameter edit mode

Up Increase Parameter / Value

Down Decrease Parameter / Value

54787AXX

[1] Display

[2] Start

[3] Stop / Reset

[4] Navigate

[5] Up

[6] Down

[1]

[2]

[3]

[4]

[5]

[6]

Pi

fkVA

Hz

n

Page 28: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

28 Catalog – MOVITRAC® LTP

3 Parameter specifications: General specifications

3.13 Parameter specifications: 3.13.1 Standard parameters

Par. Title Range Default Description

P1-01 Max speed limit (Hz or rpm) P1-02 – P1-09 x 5 (up to 2000 Hz max)

50.0 Hz (60 Hz)1)

1) If the default value is 60 Hz (460 V), this is shown on the name plate as 60 Hz.

Sets the maximum speed limit. Display of Hz or rpm dependent on P1-10. Maximum speed limit dependent on switch-ing frequency: Max Limit = P2-24 / 16.

P1-02 Min speed limit (Hz or rpm) 0 – P1-01 0.0 Hz Minimum speed limit. Hz or rpm display depending on P1-10.

P1-03 Acceleration ramp time (s) 0.0 s … 3000 s 5.0 s Time to ramp from 0 to rated frequency (P1-09)

P1-04 Deceleration ramp time (s) 0.0 s … 3000 s 5.0 s Time to ramp from rated frequency (P1-09) to 0. If a braking resistor is not fitted the ramp time will be extended automatically to pre-vent over-voltage trip.

P1-05 Stop mode select 0: Ramp to stop

0: Ramp to stop

If the supply is lost and P1-05 = 0 then the drive will try to continue running by reducing the speed of the load using the load as a generator. If P-05 = 2, the drive ramps on 2nd decelera-tion ramp P2-25 to stop.

1: Coast to stop

2: Ramp to stop

P1-06 Energy optimisation(V/f mode only)

0: Disable 0 When enabled, automatically reduces applied motor voltage on light load.1: Enable

P1-07 Motor rated voltage 20 V – 250 V 230 V Set to motor rated voltage from nameplate.Range limited to 250 V for 230 V drives.Rated (nameplate) voltage of the motor in volts. The value is limited to 250 V for low voltage drives. Setting to 0 disables voltage compensation.

20 V – 500 V 400 V (460 V)1)

20 V – 600 V 575 V

P1-08 Motor rated current limit 20 % to 100 % of drive related current

Drive rating Set to motor rated current from nameplate (Amps).

P1-09 Motor rated frequency 25 – 2000 Hz 50.0 Hz (60.0 Hz)1)

Set to motor rated frequency from name-plate (Hz). Maximum limit dependent on switching fre-quency: Max Limit = P2-24 / 16.

P1-10 Motor rated speed 0 – 60000 rpm 0 When not set to 0 all speed-related parame-ters are displayed in rpm.

P1-11 Preset speed 1 –P1-01 – +P1-01 50 Hz (60 Hz)1) Sets jog / preset speed at which drive runs when preset speed 1 selected via digital inputs (see P2-01).

P1-12 Terminal / Keypad control of drive

0: Terminal control

0: Terminal control

Set to 0 for terminal control.Set to 1 for uni-direction keypad control.Set to 2 for bi-directional keypad control.Keypad <start> key toggles between for-ward and reverse.User PID (feedback control) set in parame-ter group 3.

1: Keypad control (fwd only)

2: Keypad control (fwd and rev)

3: Enable user PID

4: Enable MODBUS network control

Drive controlled via integrated MODBUS RTU interface.

P1-13 Trip log Last 4 trips stored – Latest 4 trips stored. Most recent displayed first.

P1-14 Extended menu access code

0 – 30000 0 Permits access to extended menu when P1-14 = P2-37. Default access value = 101.

Pi

fkVA

Hz

n

Page 29: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 29

3 Parameter specifications:General specifications

3.13.2 Extended parameters

Par. Description Range Default Explanation

P2-01 Digital input function select 0 – 22 0 Defines the function of the digital inputs.

P2-02 Preset speed 2 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 2

P2-03 Preset speed 3 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 3

P2-04 Preset speed 4 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 4

P2-05 Preset speed 5 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 5

P2-06 Preset speed 6 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 6

P2-07 Preset speed 7 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 7

P2-08 Preset speed 8 –P1-01 – +P1-01 0.0 Hz Sets jog / preset speed 8

P2-09 Skip frequency P1-02 – P1-01 0.0 Hz Centre point of skip frequency band set up in conjunction with P2-10.

P2-10 Skip frequency band 0 – P1-01 0.0 Hz (disable)

Width of skip frequency band centred on frequency set in P2-09.

P2-11 Analog output / Digital output 1Function select

(Digital output mode) 7 Digital output mode. Logic 1 = DC +24 V

0: Drive enabled 0: Logic 1 when drive enabled (running)

1: Drive healthy 1: Logic 1 when no fault condition exists on drive

2: Motor at target speed 2: Logic 1 when motor speed matches set-point speed

3: Motor speed > 0 3: Logic 1 when motor runs above zero speed

4: Motor speed ≥ limit 4 - 6: Digital output enabled using level set in P2-12h and P2-12L5: Motor torque ≥ limit

6: 2nd analog input ≥ limit

(Analog output mode) (Analog output mode)1)

1) Analog output format refers to P2-36

7: Motor speed 7: Motor speed, 0 – 10 V = 0 – P-01

8: Motor torque 8: Motor torque, 0 – 10 V = 0 – 200 % of motor rated torque

9: Motor power (kW) 9: Motor power, 0 – 10 V = 0 – 150 % of drive rated power

10: Motor current 10: Motor current, 0 – 10 V = 0 – 200 % of P1-08

P2-12(h) Digital output control high limit

Speed : 0 – 200 %(200 % = max speed)Torque : 0 – 200 %(200 % = rated torque)PID feedback : 0 – 200 %(200 % = max 2nd analog input)

100 % Digital output state set to logic 1 when selected value in P2-11 larger than this limit.Limit in P2-12 relates to speed if P2-11 = 4, to motor torque if P2-11 = 5 or to the PID feedback value (2nd analog input) if P2-11 = 6.

P2-12(L) Digital output control low limit

0 … P2-12(h) 100 % Digital output state back to logic 0 when selected value in P2-11 less than or equal to this limit. (P2-11 = 4,5 or 6)

P2-13 User relay output function select

0: Drive enabled 1 If P2-15 = 0 (Normally Open), the relay contacts are closed when the selected con-dition is fulfilled.If P2-15 = 1 (Normally Closed), the relay contacts are open when the selected condi-tion is fulfilled.

1: Drive healthy

2: Motor at target speed

3: Motor speed > 0

4: Motor speed ≥ limit

5: Motor torque ≥ limit

6: 2nd analog input ≥ limit

Pi

fkVA

Hz

n

Page 30: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

30 Catalog – MOVITRAC® LTP

3 Parameter specifications: General specifications

Par. Description Range Default Explanation

P2-14(h) User relay output control high limit

Speed : 0 – 200 %(200 % = max speed)Torque : 0 – 200 %(200 % = rated torque)PID feedback : 0 – 200 %(200 % = max 2nd analog input)

100 % User relay output closes (P2-15=0) when selected value in P2-13 larger than this limit. Limit in P2-14 relates to speed if P2-13 = 4, to motor torque if P2-13 = 5 or to the PID feedback value (2nd analog input) if P2-13 = 6.

P2-14(L) User relay output control low limit

0 … P2-14(h) 100 % Digital output state back to logic 0 when selected value in P2-13 less than or equal to this limit. (P2-13 = 4,5 or 6)

P2-15 Relay output mode 0: Normally Open (NO) 0 (NO) The drive must be powered up for the relay contacts to be closed.1: Normally Closed (NC)

P2-16 Zero Speed holding time 0 … 60 s

0.2 s Determines the time for which the zero speed is held on the output before disabling the drive.

P2-17 Start mode select Edgr-r Close digital input 1 after power up to start drive

Auto-0 When set to Edge-r, if drive is powered up with digital Input 1 closed (enabled), drive will not run. The switch (digital input 1) must be opened and closed after power up or after a clear-ing a trip for the drive to run.When set to Auto-0, drive will run whenever digital input 1 is closed (if not tripped).Auto-1…5 makes 1…5 attempts to auto-matically restart after a trip (20 s between attempts in default). Drive must be powered down to reset the counter.

Auto-0 Drive runs whenever digi-tal input 1 is closed

Auto-1…5

As Auto-0, except 1..5 attempts to restart after a trip

P2-18 Spin Start Enable(V/f mode only)

0: Disable 0 When enabled, drive detects motor speed and starts driving the motor from this speed (the motor speed can be in both directions: forward or reverse).A short delay of approx. 1 s will result after enabling the drive before speed is detected.This function only works when parameter P4-01 = 2.

1: Enable

P2-19 Keypad restart mode 0: Minimum speed 1 If set to 0 or 2, drive will always start from minimum speed. If set to 1 or 3, drive ramps up to the oper-ating speed prior to the last STOP com-mand. If set to 2 and 3, the status of digital input 1 controls drive to start or stop. The start and stop button will not work in this case.

1: Previous speed

2: Min-speed (Auto-r)

3: Previous speed (Auto-r)

P2-20 Standby mode 0: Disable1 … 60 s

0.0 s If P2-20 > 0, drive enters standby mode (disables output) if minimum speed is main-tained for the time specified in P2-20. If P2-16 > 0, this function is disabled.

P2-21 Display scaling factor 0.000 – 30.000 0.000 Disabled if set to zero. The variable selected in P2-22 is multiplied by this factor and displayed as a real-time value on the drive, in addition to speed, current and power.

P2-22 Display scaling source 0: 2nd analog input 0 Selects the variable to be scaled by the factor set in P2-21. 1: Motor speed

2: Motor torque

3: Motor current

Pi

fkVA

Hz

n

Page 31: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 31

3 Parameter specifications:General specifications

P2-23 Brake circuit enable 0: Disable 0 Enables the internal brake chopper. Overload protection in software when set to 1 or 2. See rating tables for resistor sizing guidelines.

1: Enable + lo power

2: Enable + hi power

3: Enable, no protection

P2-24 Effective switching frequency

S1, S2 230 V, 4 – 32 kHz 16 kHz Effective power stage switching frequency.X1: higher switching frequency means less noise development on the motor but higher losses at output stage.

S2 400 V, 4 – 32 kHz 8 kHz

S3, S4 400 V, 4 – 24 kHz 4 kHz

S5, S6 400 V, 4 – 16 kHz 4 kHz

Auto "Auto" selects minimum possible switching frequency for the speed range selected to minimize losses in spindle applications. (P2-24 must be 16 x P1-01 or greater.)

P2-25 Second deceleration ramp time

0 s – 3000 s 0.0 s Selected automatically on mains loss if P1-05 = 2. Can also be selected via digital inputs during operation.

P2-26 MODBUS communication baudrate

t9.6, t19.2, t38.4, t57.6, t115.2r9.6, r19.2, r38.4, r57.6, r115.2

0 Kbaud MODBUS RTU serial data link communica-tion baudrate. A ’t’ suffix indicates the drive will trip if com-munication with the network master is lost, after the time period set in P6-08.An ’r’ suffix indicates that the drive will ramp to stop if communication with the net-work master is lost, after the time period set in P6-08.

P2-27 Drive communication address

0: Disable 1 Distinct drive address used for all drive serial communications.1 – 63: Communication address

P2-28 Master / Slave mode select 0: Slave mode 0 When in Master mode, the drive transmits its operational status via the serial data link. Used to control slave drives via the serial link. P2-27 must be 1 for Master mode.

1: Master mode

P2-29 Digital speed reference preset scaling factor

0 … 500 %, steps of 0.1 % 100.0 % The digital speed reference input to the drive is scaled by this factor when P2-35 = 1. Operates on references origi-nating from the serial data link. Can be used as an electronic gearbox for Master / Slave applications.

P2-30 Bipolar analog input format 0 – 24 V0 – 10 V–10 – +10 V–24 – +24 V

0 – 24 V Configures the analog input format to match the reference signal connected to terminal 6. Only voltage signals can be directly connected, mA reference signals require an external resistor connection.

P2-31 Bipolar analog input scal-ing

0 – 500 % 100.0 % Scales the analog input by this factor. Set to 200 % to give full speed range con-trol with 0 – 5 V input (when P2-30 = 0 – 10 V).

P2-32 Bipolar analog input offset –500 % – +500 % 0.0 % Sets the offset from zero at which speed starts to ramp up. Value is “%” of the full scale input voltage.

P2-33 2nd analog input format 0 / 24 V (digital input)0 – 10 V,4 – 20 mA, 0 – 20 mA

0 / 24 V Determines the format of the 2nd analog input.Selecting 0 / 24 V sets up the input as a digital input.

P2-34 2nd analog input scaling 0 – 500 % 100.0 % Scales the 2nd analog input by the factor set in this parameter.

Par. Description Range Default Explanation

Pi

fkVA

Hz

n

Page 32: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

32 Catalog – MOVITRAC® LTP

3 Parameter specifications: General specifications

P2-35 Digital speed reference scaling control

0: Disabled (no scaling) 0 Only active in keypad mode (P1-12 = 1 or 2) and Master / Slave mode.1: Actual speed = digital speed × P2-292: Actual speed = (digital speed × P2-29) + bipolar analog reference3: Actual speed = (digital speed × P2-29) × bipolar analog reference

1: Scaled by P2-29

2: Scaled by P2-29, bipolar with analog input added as offset

3: Scaled by P2-29 and by bipolar analog input

P2-36 Analog output format 0 – 10 V, 4 – 20 mA, 10 – 0 V, 20 – 4 mA

0 – 10 V Determines the analog output format. Min load impedance in voltage mode: 1 k ΩMax load impedance in current mode:1 k Ω

P2-37 Extended menu access code define

0 … 9999 101 Defines the extended menu access code used in P1-14.

P2-38 Parameter Lock 0: Unlocked 0 When locked, all parameter changes are prevented.1: Locked

P2-39 Hours run clock 0 – 99999 hours Read only

Indicates the number of hours the drive has been running since new.

P2-40 Drive type / rating – Read only

Indicates drive power rating, type code and voltage rating.

Par. Description Range Default Explanation

Pi

fkVA

Hz

n

Page 33: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 33

3 Parameter specifications:General specifications

3.13.3 User feedback control (PID control)

These parameters are not available in drives with MODBUS software (-xM).

Par. Description Range Default Explanation

P3-01 Proportional gain 0.1 – 30.0 2 PID Controller Proportional Gain. Higher values pro-vide a greater change in the drive output frequency in response to small changes in the feedback signal. Too high a value can cause instability.

P3-02 Integral time constant 0.0 s – 30.0 s 1 s PID Controller Integral Time. Higher values provide a more damped response for systems where the over-all process responds slowly.

P3-03 Differential time constant 0.00 s – 1.00 s 0.00 Can be set to zero (disabled) for most applications.

P3-04 PID operating mode 0: Direct1: Inverse

0 Direct operation: Motor speed increases with an increase in the feedback signal.Inverse operation: Motor speed decreases with an increase in the feedback signal.

P3-05 PID Setpoint / reference select

0: Digital1: Analog

0 Sets the source for the PID reference / setpoint.0: P3-06 is used1: Bipolar analog input is used

P3-06 PID digital reference 0 … 100 % 0.0 % Sets the preset digital PID reference / setpoint.

P3-07 PID controller high limit output

P3-08 – 100 % 100 % Limits the maximum value output from the PID controller.

P3-08 PID controller low limit output

0 – P3-07 0.0 % Limits the minimum output from the PID controller.

P3-09 PID output limit / function control

0: Digital output limits1: Analog upper limit2: Analog lower limit3: PID output + biploar ana-log input reference

0 0: PID output range limited by P3-07 & P3-081: PID maximum output limited by signal applied to the bipolar analog input.2: PID minimum output limited by signal applied to the bipolar analog input3: PID output added to speed reference applied to the bipolar analog input

P3-10 PID feedback source select

0: 2nd analog input1: Bipolar analog input

0 Selects the source of the PID feedback signal.

Pi

fkVA

Hz

n

Page 34: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

34 Catalog – MOVITRAC® LTP

3 Parameter specifications: General specifications

3.13.4 High performance motor control

Par. Description Range Default Explanation

P4-01 Control mode 0: Speed control (vector)1: Torque control (vector)2: Speed control (V/f)

2 Whenever changing control mode, ensure that an Auto-tune (P4-02) is always carried out for best motor performance. Set to 0 for speed control with variable torque limits.

P4-02 Motor parameter auto-tune 0: Disable1: Enable

0 When set to 1, the drive immediately carries out a static (non-rotating) motor parameter measurement operation to configure the motor parameters. P1-07, P1-08 and P1-09 must be set correctly according to the motor nameplate before enabling this function. Auto-tune runs automatically on first enable after parameter default operation and P1-08 has been changed. No hardware enable is required.

P4-03 Speed controller Proportional gain

0 … 4096 (internal value) Drive rating

Too high a value can cause instability. Only available in vector mode.

P4-04 Speed controller Integral time constant

0.000 … 1.000 s 0.05 s Higher value gives slower, more damped response. Only available in vector mode.

P4-05 Motor factor power 0.50 … 0.99 Drive rating

Motor nameplate power factor (cos Φ).Required for all vector control modes.

P4-06 Torque reference select 0: Preset value1: Bipolar analog input2: 2nd analog input3: MODBUS ref

0 Used when in vector control mode to set a maximum torque limit.

P4-07 Torque reference preset value

0 … 200 % 200.0 % Preset value used when P4-06 = 0. 100 % is rated motor torque.

P4-08 Minimum torque reference limit

0 …150 % 0.0 % Defines the minimum limit for output motor torque

P4-09 V/f characteristic adjust-ment frequency

0 … P1-09 0.0 Hz Sets the frequency at which the adjustment voltage (P4-10) is applied.

P4-10 V/f characteristic adjust-ment voltage

0 … P1-07 0 Sets the motor voltage to this value at the frequency set in P4-09.

Pi

fkVA

Hz

n

Page 35: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 35

3 Selection of Parameter P2-01, Digital Input FunctionGeneral specifications

3.14 Selection of Parameter P2-01, Digital Input FunctionThe functionality of the digital inputs within the MOVITRAC® LTP is user programmable,allowing the user to select the functions required for the application.The following tables define the functions of the digital inputs depending on the value ofparameter P1-12 (Terminal / keypad control) and P2-01 (Selection of digital input func-tion).

3.14.1 Selection table if P1-12 = 0 (Terminal mode)

P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments / Preset value

0 O: Stop (Disable)C: Run (Enable)

O: Analog input C: Preset speed 1, 2

O: Preset speed 1 C: Preset speed 2

Bipolar analog input

DI3 selects speed if DI2 is closed

1 O: Stop (Disable)C: Run (Enable)

O: Preset speed 1C: Preset speed 2

O: Preset speed 1, 2 C: Preset speed 3

O: Preset speed 1,2,3 C: Preset speed 4

2 O: Stop (Disable)C: Run (Enable)

Open Open Open Preset speed 1

Closed Open Open Preset speed 2

Open Closed Open Preset speed 3

Closed Closed Open Preset speed 4

Open Open Closed Preset speed 5

Closed Open Closed Preset speed 6

Open Closed Closed Preset speed 7

Closed Closed Closed Preset speed 8

3 O: Stop (Disable)C: Run (Enable)

O: ForwardC: Reverse

O: Analog input C: Preset speed 1

Bipolar analog input

4 O: Stop (Disable)C: Run (Enable)

O: ForwardC: Reverse

2nd analog input Bipolar analog input

P4-06 = 0 or 1speed reference at 2nd analog inputP4-06 = 2bipolar input is speed reference, 2nd analog input is torque ref.P2-36 sets format of DI3

5 O: Stop (Disable)C: Run (Enable)

O: ForwardC: Reverse

Open Open Preset speed 1

Closed Open Preset speed 2

Open Closed Preset speed 3

Closed Closed Preset speed 4

6 O: Stop (Disable)C: Run (Enable)

O: ForwardC: Reverse

External trip input:O: Trip C: OK

Bipolar analog input

Connect an external PTC motor thermistor or similar to DI3

7 O: Stop (Disable)C: Run Forward

O: Stop (Disable)C: Run Reverse

O: Analog input C: Preset speed 1

Bipolar analog input

8 O: Stop (Disable)C: Run Forward

O: Stop (Disable)C: Run Reverse

O: Preset speed 1C: Analog input

Bipolar analog input

9 O: Stop (Disable)C: Run Forward

O: Stop (Disable)C: Run Reverse

Open Open Preset speed 1

Closed Open Preset speed 2

Open Closed Preset speed 3

Closed Closed Preset speed 4

Pi

fkVA

Hz

n

Page 36: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

36 Catalog – MOVITRAC® LTP

3 Selection of Parameter P2-01, Digital Input Function General specifications

10 O: Stop (Disable)C: Run Forward

O: Stop (Disable)C: Run Reverse

External trip input:O: Trip C: OK

Bipolar analog input

Connect an external PTC motor thermistor or similar to DI3

11 O: Stop (Disable)C: Run (Enable)

O: Analog input C: Preset speed 1

External trip input:O: Trip C: OK

Bipolar analog input

Connect an external PTC motor thermistor or similar to DI3

12 O: Stop (Disable)C: Run (Enable)

O: Preset speed 1C: Analog input

External trip input:O: Trip C: OK

Bipolar analog input

Connect an external PTC motor thermistor or similar to DI3

13 Normally Open (NO)Momentarily close to run forward

Normally Closed (NC)Momentarily open to run

O: Analog inputC: Preset speed 1

Bipolar analog input

14 Normally Open (NO)Momentarily close to run forward

Normally Closed (NC)Momentarily open to stop

Normally Open (NO)Momentarily close to run reverse

Bipolar analog input

15 O: Stop (Disable)C: Run (Enable)

O: ForwardC: Reverse

O: Decel ramp 1C: Decel ramp 2

Bipolar analog input

16 O: Stop (Disable)C: Run (Enable)

O: ForwardC: Reverse

O: Decel ramp 1C: Decel ramp 2

O: Preset speed 1 C: Preset speed 2

17 Normally Open (NO)Momentarily close to run forward

Normally Closed (NC)Momentarily open to stop

Normally Open (NO)Momentarily close to run reverse

O: Preset speed 1 C: Keypad mode

Up and Down buttons can be used to set the speed when analog input is set to keypad mode.

18 O: Stop (Disable)C: Run (Enable)

Open Open O: Terminal modeC: Keypad mode

Preset speed 1

Closed Open Preset speed 2

Open Closed Preset speed 3

Closed Closed Preset speed 4

19 O: Stop (Disable)C: Run (Enable)

O: Analog inputC: 2nd analog input

2nd analog input Bipolar analog input

20 O: Stop (Disable)C: Run (Enable)

2nd digital output (+24 V)

O: Analog inputC: Preset speed 1

Bipolar analog input

2nd digital output shows drive healthy

21 O: Stop (Disable)C: Run (Enable)

2nd digital output (+24 V)

O: ForwardC: Reverse

Bipolar analog input

2nd digital output shows drive healthy

22 O: Stop (Disable)C: Run (Enable)

2nd digital output (+24 V)

External trip input:O: Trip C: OK

Bipolar analog input

2nd digital output shows drive healthy

P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments / Preset value

NOTEWhen P2-01 = 20, the 2nd digital input is configured as an output, which outputs +24 Vwhen the drive is healthy. If the drive is not healthy, the output will be 0 V.When connecting a motor thermistor, connect it between terminals 1 and 4. Set P2-01 to 6, 10, 11, 12 or 22 (uses external trip input).

Pi

fkVA

Hz

n

Page 37: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 37

3 Selection of Parameter P2-01, Digital Input FunctionGeneral specifications

3.14.2 Selection table if P1-12 = 1 or 2 (Keypad mode)

When P2-01 = 17 or 18, keypad mode is selected from within terminal mode (see page35). For this reason, the remaining digital inputs have no effect.When P2-19 = 2 or 3 in keypad mode, the drive start and stop is controlled from the hard-ware enable input (terminal 2). In this case, the <start> / <stop> buttons are not requiredand therefore have no effect.Reverse rotation control by analog input only works when P1-12 = 2.When connecting a motor thermistor, connect it between terminals 1 & 4 and setP2-01 to 6, 10, 11, 12 or 22 (uses external trip output).

P2-01 Digital input 1 (DI1)

Digital input 2 (DI2)

Digital input 3 (DI3) Analog input (AI) Comments / Preset value

0 O: Stop (Disable)C: Run (Enable)

C: Increase speed C: Decrease speed No effect Close DI2 & DI3 simultaneously to start drive.

1 O: Stop (Disable)C: Run (Enable)

C: Increase speed External trip input:O: Trip C: OK

C: Decrease speed Close DI2 & analog input simulta-neously to start drive.Connect an external PTC motor thermistor or similar to DI3.

2 O: Stop (Disable)C: Run (Enable)

C: Increase speed O: Digital speed ref C: Preset speed 1

Analog input > 5 V reverses rotation.

Reverse operation only available in P1-12 = 2.

3 – 9, 13, 14, 16 1)

O: Stop (Disable)C: Run (Enable)

C: Increase speed C: Decrease speed O: ForwardC: Reverse

Close DI2 & DI3 simultaneously to start drive.

10 O: Stop (Disable)C: Run (Enable)

O: Digital speed ref C: Analog input

External trip input:O: Trip C: Run

Analog speed ref Connect an external PTC motor thermistor or similar to DI3.

11 O: Stop (Disable)C: Run (Enable)

O: Digital speed ref C: Preset speed 1

External trip input:O: Trip C: Run

Analog input > 5 V reverses rotation.

Connect an external PTC motor thermistor or similar to DI3.

12 O: Stop (Disable)C: Run (Enable)

O: Preset speed 1C: Analog input

External trip input:O: Trip C: Run

Analog input > 5 V reverses rotation.

Connect an external PTC motor thermistor or similar to DI3.

15 O: Stop (Disable)C: Run (Enable)

O: Digital speed ref C: Preset speed 1

O: Decel ramp 1C: Decel ramp 2

Analog input > 5 V reverses rotation.

17 O: Stop (Disable)C: Run (Enable)

O: Digital speed ref C: Analog input

O: Digital / analog speedC: Preset speed 1

Analog speed ref DI3 overrides DI2.

18 O: Stop (Disable)C: Run (Enable)

O: Digital speed ref C: Preset speed

Open Open Preset speed 1

Closed Open Preset speed 2

Open Closed Preset speed 3

Closed Closed Preset speed 4

19 O: Stop (Disable)C: Run (Enable)

O: Digital speed ref C: 2nd analog input

No effect Analog input > 5 V reverses rotation.

20, 21 O: Stop (Disable)C: Run (Enable)

2nd digital output: (+24 V)

O: Digital speed ref C: Preset speed 1

Analog input > 5 V reverses rotation.

2nd digital output shows drive healthy.

22 O: Stop (Disable)C: Run (Enable)

2nd digital output: (+24 V)

External trip input:O: Trip C: Run

Analog input > 5 V reverses rotation.

Connect an external PTC motor thermistor or similar to DI3.2nd digital output shows drive healthy.

1) In addition to the speed being set using the pushbuttons on the front of the drive, these settings allow the speed to be controlledremotely using remote pushbuttons connected to digital inputs 1, 2 and 3.

Pi

fkVA

Hz

n

Page 38: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

38 Catalog – MOVITRAC® LTP

3 Selection of Parameter P2-01, Digital Input Function General specifications

Example: Motor potentiometer function - crane applications

To run the motor potentiometer function, the following parameters must be set:

P1-02 = Minimum speed (ex. 100 rpm)P1-03 = Acceleration time (ex. 10 s)P1-04 = Deceleration time (ex. 10 s)P1-11 = Safety end limit speed set point (ex. 300 rpm)P1-12 = 1 (keypad mode)P2-01 = 2 (digital input function)P2-19 = 2 (auto restart, minimum speed)

57211AXX

[1] Enable / Ramp down

[2] Ramp up

[3] Preset speed 1

[4] Change direction (forward / reverse)

1 765432

[1] [2] [4][3]

Pi

fkVA

Hz

n

Page 39: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 39

3 Selection of Parameter P2-01, Digital Input FunctionGeneral specifications

3.14.3 Selection table if P1-12 = 3 (User PID mode)

The following table defines the function of the digital inputs when the drive is in User PIDcontrol mode (set using P1-12 = 3).

P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments

0 – 10,13 – 18

O: Stop (Disable)C: Run (Enable)

No effect No effect Bipolar analog input –

11 O: Stop (Disable)C: Run (Enable)

O: PID control C: Preset speed 1

External trip input:O: Trip C: Run

Connect an external PTC motor thermistor or similar to DI3.P3-10 = 1 for external trip.

12 O: Stop (Disable)C: Run (Enable)

O: Preset speed 1C: PID control

External trip input:O: Trip C: Run

Connect an external PTC motor thermistor or similar to DI3.P3-10 = 1 for external trip.

17 O: Stop (Disable)C: Run (Enable)

O: PID controlC: Analog input

No effect –

19 O: Stop (Disable)C: Run (Enable)

O: PID control C: 2nd analog input

2nd analog input –

20, 21 O: Stop (Disable)C: Run (Enable)

2nd digital output:(+24 V)

No effect 2nd digital output shows drive healthy.

22 O: Stop (Disable)C: Run (Enable)

2nd digital output:(+24 V)

External trip input:O: Trip C: Run

Connect an external PTC motor thermistor or similar to DI3.P3-10 = 1 for external trip.2nd digital output shows drive healthy.

Pi

fkVA

Hz

n

Page 40: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

40 Catalog – MOVITRAC® LTP

3 Selection of Parameter P2-01, Digital Input Function General specifications

3.14.4 Selection table if P1-12 = 4 (MODBUS control)

The following table defines the function of the digital inputs when the drive is inMODBUS control mode (set using P1-12 = 4).

P2-01 Digital input 1 (DI1) Digital input 2 (DI2) Digital input 3 (DI3) Analog input (AI) Comments

0, 1, 2, 46 – 9,13, 15, 18

O: Stop (Disable)C: Run (Enable)

No effect No effect No effect –

3 O: Stop (Disable)C: Run (Enable)

O: Forward C: Reverse

O: Master speed refC: Preset speed 1

No effect –

5 O: Stop (Disable)C: Run (Enable)

O: Master speed refC: Preset speed 1

Open Open Preset speed 1

Closed Open Preset speed 2

Open Closed Preset speed 3

Closed Closed Preset speed 4

10 O: Stop (Disable)C: Run (Enable)

O: Master speed refC: Digital speed ref

External trip input:O: Trip C: Run

No effect Connect an external PTC motor thermistor or similar to DI3.

11 O: Stop (Disable)C: Run (Enable)

O: Master speed refC: Preset speed 1

External trip input:O: Trip C: Run

No effect Connect an external PTC motor thermistor or similar to DI3.

12 O: Stop (Disable)C: Run (Enable)

O: Master speed refC: Analog speed ref

External trip input:O: Trip C: Run

Analog speed refer-ence

Connect an external PTC motor thermistor or similar to DI3.

17 O: Stop (Disable)C: Run (Enable)

O: Master speed refC: Analog speed ref

O: Master / analog input speed refC: Preset speed 1

Analog speed refer-ence

If DI3 is closed, DI2 has no effect.

19 O: Stop (Disable)C: Run (Enable)

O: Master speed refC: 2nd analog input

2nd analog input No effect –

20, 21 O: Stop (Disable)C: Run (Enable)

2nd digital output:(+24 V)

O: Master speed refC: Preset speed 1

No effect 2nd digital output shows drive healthy.

22 O: Stop (Disable)C: Run (Enable)

2nd digital output:(+24 V)

External trip input:O: Trip C: Run

No effect Connect an external PTC motor thermistor or similar to DI3.2nd digital output shows drive healthy.

NOTEIf P2-19 = 2 or 3, the drive can only be started or stopped by closing or opening digitalinput 1.If P2-19 = 0 or 1, the start / stop signal must be set via bus and digital input 1.

Pi

fkVA

Hz

n

Page 41: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 41

3 Selection of Parameter P2-01, Digital Input FunctionGeneral specifications

3.14.5 Real-time monitoring parameters

Parameter group zero provides access to internal drive parameters for monitoringpurposes. These parameters cannot be adjusted.

Par. Description Display range Explanation

P0-01 Bipolar analog input value –100 % – +100 % 100 % = max input voltage

P0-02 2nd analog input value 0 – 100 % 100 % = max input voltage

P0-03 Speed controller reference –500 % – +500 % 100 % = Base frequency (P1-09)

P0-04 Digital speed ref (digi pot) – P1-01 – +P1-01 Speed displayed in Hz / rpm

P0-05 Torque controller reference 0 – 200 % 100 % = motor rated torque

P0-06 User PID ref input 0 – 100 % PID controller reference value

P0-07 User PID feedback 0 – 100 % PID controller feedback value

P0-08 User PID error input 0 – 100 % Reference – Feedback

P0-09 User PID P-term 0 – 100 % Proportional component

P0-10 User PID I-term 0 – 100 % Integral component

P0-11 User PID D-term 0 – 100 % Differential component

P0-12 User PID output 0 – 100 % Combined output

P0-13 Output Torque 0 – 200 % 100 % = motor rated torque

P0-14 Magnetizing current A rms Magnetizing current in A rms

P0-15 Rotor current A rms Rotor current in A rms

P0-16 Field strength 0 – 100 % Magnetic field strength

P0-17 Stator resistance Ohm [Ω] Phase - Phase stator resistance

P0-18 Stator inductance H Stator inductance in Henry

P0-19 Rotor resistance Ohm [Ω] Calculated rotor resistance

P0-20 DC bus voltage V DC Internal DC bus voltage

P0-21 Drive temperature °C Internal drive temperature

P0-22 Supply voltage L1 – L2 V rms, ph-ph Phase – phase supply voltage

P0-23 Supply voltage L2 – L3 V rms, ph-ph Phase – phase supply voltage

P0-24 Supply voltage L3 – L1 V rms, ph-ph Phase – phase supply voltage

P0-25 Estimated Rotor speed Hz or rpm Applies to vector modes only

P0-26 kWh meter 0.0 – 999.9 kWh Cumulative energy consumption

P0-27 MWh meter 0.0 – 60000 MWh Cumulative energy consumption

P0-28 Software ID, IO processor e.g. “1.00”, “493F” Version number and check sum

P0-29 Software ID, Motor control e.g. “1.00”, “7A5C” Version number and check sum

P0-30 Drive serial number 000000 – 999999 00-000 – 99-999

Unique drive serial numbere.g. 540102 / 24 / 003

Pi

fkVA

Hz

n

Page 42: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

42 Catalog – MOVITRAC® LTP

4 Braking resistors Accessories

4 Accessories4.1 Braking resistors4.1.1 Braking resistor circuit

MOVITRAC® LTP units have a built in braking transistor which can be used with anexternal braking resistor to convert re-generated energy from the motor into thermalenergy. This braking circuit is generally needed for applications with a fast decelerationramp or with a high inertia load.SEW also recommends protecting the wire and grid resistors against overload using abimetallic relay as shown below. The relay output must open up the supply voltage tothe MOVITRAC® LTP unit. It must not open up the connection from the braking resistorto the MOVITRAC® LTP unit. With SEW-EURODRIVE flat-type braking resistors and any other overload protectedbraking resistors, the bimetallic relay is not required.The illustration below shows the wiring diagram for the braking resistor connection.

For some inverter / resistor combinations 2 braking resistors with the same value mustbe connected in parallel. In this case, the trip current must be set on the bimetallic relayto twice the value of IF entered in the following tables. For the BW...-T and BW...-Pbraking resistors the temperature switch / overcurrent relay must be connected inseries.

57643AENFigure 2: Wiring diagram for braking resistor connection

U V W + BR

BW...

F16

affectsK11

Page 43: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 43

4 Braking resistorsAccessories

4.1.2 Minimum braking resistor values

MOVITRAC® LTP 230 V 400 V 525 V 575 V

0.75 kW – 47 – 47

1.5 kW 33 47 – 47

2.2 kW 22 47 – 47

3.0 kW 15 – – –

4.0 kW 15 33 – 47

5.5 kW 15 22 – 47

7.5 kW 6 22 – 22

11 kW 6 22 – 22

15 kW 6 22 – 22

18.5 kW 6 12 – –

22 kW 3 12 – 12

30 kW 3 12 – 12

37 kW 3 12 – –

45 kW 3 6 – 12

55 kW 3 6 6 –

75 kW 3 6 6 –

90 kW 3 6 6 –

110 kW – 6 6 –

132 kW – 6 6 –

160 kW – 6 6 –

Page 44: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

44 Catalog – MOVITRAC® LTP

4 Braking resistors Accessories

4.1.3 Flat design braking resistors

The flat-design resistors have degree of protection IP54 and are equipped with internalthermal overload protection (cannot be replaced). Depending on their type, you caninstall the resistors as follows:• With support rail mounting FHS or submounting FKB under the heat sink. The

braking resistors in the submounting do not achieve the specified CDF power. TheFHS and FKB options are only suitable for the BW027-003 and BW072-003 brakingresistors.

• Attach to a mounting rail using a BS touch guard.Caution: The load capacity applies for a horizontal mounting position [2]. Values arereduced by 10 % for a vertical mounting position [1].

64745AXX

[1][2]

Braking resistor type BW027-003 BW027-005 BW047-003 BW047-005 BW072-003 BW072-005 BW100-005

Part number 826 949 1 826 950 5 826 265 9 826 268 3 826 058 3 826 060 5 826 269 1

100 % CDF50 % CDF25 % CDF12 % CDF6 % CDF

230 W310 W410 W550 W980 W

450 W610 W840 W1200 W2360 W

250 W330 W430 W580 W1050 W

450 W610 W840 W1200 W2360 W

230 W310 W420 W580 W1000 W

450 W610 W840 W1200 W2360 W

450 W610 W840 W1200 W2360 W

Resistance value RBW 27 Ω ±10 % 47 Ω ±10 % 72 Ω ±10 % 100 Ω ±10 %

Trip current IF 1.0 A 1.4 A 0.8 A 1.2 A 0.6 A 1.0 A 0.8 A

Ambient temperature ϑ U –20 °C to +45 °C

Page 45: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 45

4 Braking resistorsAccessories

4.1.4 Wire and grid resistors

• Perforated sheet cover (IP20) open towards the mounting surface• The short-time load capacity of the wire and grid resistors is greater than in the flat-

type braking resistors

SEW-EURODRIVE recommends also protecting the wire and grid resistors againstoverload using a bimetallic relay. Set the trip current to the value IF in the table. Do notuse any electronic or electromagnetic fuses since even the brief excess currents whichare still permitted may cause them to trip.The surfaces of the resistors get very hot if loaded with PN. Bear this aspect in mindwhen selecting the installation location. Braking resistors are therefore mounted on thecontrol cabinet roof.

Assignment to AC 230 V units

Braking resistor type BW... BW039-003

BW039-006

BW039-012

BW027-006

BW027-012

Part number 821 687 8 821 688 6 821 689 4 822 422 6 822 423 4Braking resistor type BW...-T BW039-

012-TBW039-026-T

BW018-015-P

BW018-035-T

Part number 1820 136 9 1820 415 5 1820 416 3 1820 138 5Continuous braking power (100% cdf)Load capacity 50 % cdf1)

at 25 % cdf12 % cdf6 % cdf

0.3 kW0.5 kW1.0 kW1.8 kW2.8 kW

0.6 kW1.1 kW1.9 kW3.6 kW5.7 kW

1.2 kW2.1 kW3.8 kW

6.0 kW2)

6.0 kW2)

2.6 kW4.6 kW

6.0 kW2)

6.0 kW2)

6.0 kW2)

0.6 kW1.1 kW1.9 kW3.6 kW5.7 kW

1.2 kW2.1 kW3.8 kW7.2 kW

8.7 kW2)

1.5 kW2.5 kW4.5 kW6.7 kW11.4 kW

3.5 kW5.9 kW10.5 kW

13.0 kW2)

13.0 kW2)

Observe regenerative power limit of the inverter!(= 150 % of the recommended motor power → technical data)

Resistance value RBW 39 Ω ±10 % 27 Ω ±10 % 18 Ω ±10 %Trip current (of F16) IF 2.7 ARMS 3.9 ARMS 5.5 ARMS 8.1 ARMS 4.7 ARMS 6.6 ARMS 9.1 ARMS 13.9 ARMSDesign Wire resistor Grid resistorConnections /tightening torque

Ceramic terminals 2.5 mm2 (AWG12) /0.5 Nm

M8 stud /6 Nm

Degree of protection IP20 (when installed)Ambient temperature ϑ U –20 to +40 °CType of cooling KS = Self-coolingFor MOVITRAC® LTP (recommended) 0015/0022 0022/0030 0030 – 00553)

1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration TD ≤ 120 s.2) Physical power limit due to DC link voltage and resistance value.3) When connected in parallel, the load capacity and trip current are doubled.

Page 46: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

46 Catalog – MOVITRAC® LTP

4 Braking resistors Accessories

Assignment to AC 400 – 575 V units

Braking resistor type BW...-T/-P BW018-075-T BW915-T BW012-

025-PBW012-050-T

BW012-100-T BW106-T BW206-T

Part number 1820 139 3 1820 413 9 1820 414 7 1820 140 7 1820141 5 1820 083 4 1820 412 0Continuous braking power (100% cdf)Load capacity 50 % cdf1)

at 25 % cdf12 % cdf6 % cdf

7.5 kW12.7 kW

13.0 kW2)

13.0 kW2)

13.0 kW2)

15.6 kW2)

15.6 kW2)

15.6 kW2)

15.6 kW2)

15.6 kW2)

2.5 kW4.2 kW7.5 kW11.2 kW19.0 kW

5.0 kW8.5 kW

15.0 kW19.6 kW2)

19.6 kW2)

10 kW17 kW

19.6 kW2)

19.6 kW2)

19.6 kW2)

13.5 kW23 kW

39.2 kW2)

39.2 kW2)

39.2 kW2)

18 kW30.6 kW

39.2 kW2)

39.2 kW2)

39.2 kW2)

Observe regenerative power limit of the inverter!(= 150 % of the recommended motor power → technical data)

Resistance value RBW 18 Ω ±10 % 15 Ω±10 % 12 Ω ±10 % 6 Ω ±10 %

Trip current (of F16) IF 20.4 ARMS 32.6 ARMS 14.4 ARMS 20.4 ARMS 28.8 ARMS 47.4 ARMS 54.7 ARMSDesign Grid resistorConnections /tightening torque

M8 stud /6 Nm

Degree of protection IP20 (when installed)Ambient temperature ϑ U –20 – +40 °CType of cooling KS = Self-coolingFor MOVITRAC® LTP (recommended) 0030 – 00553) 0075 – 0185 0075 – 09003)

1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration TD ≤ 120 s.2) Physical power limit due to DC link voltage and resistance value.3) When connected in parallel, the load capacity and trip current are doubled.

Braking resistor type BW... BW147 BW247 BW347 BW039-012

Part number 820 713 5 820 714 3 820 798 4 821 689 4

Braking resistor type BW...-T BW147-T BW247-T BW347-T BW039-012-T BW039-026-T BW039-050-T

Part number 1820 134 2 1820 084 2 1820 135 0 1820 136 9 1820 415 5 1820 137 7

Continuous braking power (100% cdf)Load capacity 50 % cdf1)

at 25 % cdf12 % cdf6 % cdf

1.2 kW2.2 kW3.8 kW7.2 kW11 kW

2.0 kW3.6 kW6.4 kW12 kW19 kW

4.0 kW7.2 kW12.8 kW20 kW2)

20 kW2)

1.2 kW2.1 kW3.8 kW7.2 kW11.4 kW

2.6 kW4.7 kW8.3 kW

15.6 kW24.0 kW2)

5.0 kW8.5 kW15.0 kW

24.0 kW2)

24.0 kW2)

Observe regenerative power limit of the inverter!(= 150 % of the recommended motor power → technical data)

Resistance value RBW 47 Ω ±10 % 39 Ω ±10 %

Trip current (of F16) IF 5 ARMS 6.5 ARMS 9.2 ARMS 5.5 ARMS 8.1 ARMS 11.3 ARMS

Design Wire resistor on ceramic core Grid resistor

Connections /tightening torque

Ceramic terminals 2.5 mm2 (AWG13) / 0.5 NmBW347-T: Ceramic terminals 10 mm2 (AWG18) / 1.6 Nm

M8 stud /6 Nm

Degree of protection IP20 (when installed)

Ambient temperature ϑ U –20 – +40 °C

Type of cooling KS = Self-cooling

For MOVITRAC® LTP (recommended) 0040/0055 0055 – 0150

1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration TD ≤ 120 s.2) Physical power limit due to DC link voltage and resistance value.

Page 47: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 47

4 Braking resistorsAccessories

Technical data of the braking resistor BW...-T / BW...-P

Braking resistor type BW...- BW012-025

Part number 821 680 0

Braking resistor type BW...-T/-P BW012-025-P BW012-050T BW012-100-T BW106-T BW206-T

Part number 1820 414 7 1820 140 7 1820 141 5 1820 083 4 1820 412 0

Continuous braking power (100% cdf)Load capacity 50 % cdf1)

at 25 % cdf12 % cdf6 % cdf

2.5 kW4.2 kW7.5 kW11.2 kW19.0 kW

5.0 kW8.5 kW15.0 kW22.5 kW38.0 kW

10 kW17 kW30 kW45 kW76 kW

13.5 kW23 kW40 kW61 kW102 kW

18 kW30.6 kW54 kW81 kW

136.8 kW

Observe regenerative power limit of the inverter!(= 150 % of the recommended motor power → technical data)

Resistance value RBW 12 Ω ±10 % 6 Ω ±10 %

Trip current (of F16) IF 14.4 ARMS 20.4 ARMS 28.8 ARMS 47.4 ARMS 54.7 ARMS

Design Grid resistor

Connections /tightening torque

Ceramic terminals 2.5 mm2 (AWG13) / 0.5 NmBW012-025-P: Terminals 4 mm2 (AWG12) / 1 Nm Bolt M8 / 6 Nm

Degree of protection IP20 (when installed)

Ambient temperature ϑ U –20 – +40 °C

Type of cooling KS = Self-cooling

For MOVITRAC® LTP (recommended) 0185 – 0370 0450 – 16002)

1) cdf = Cyclic duration factor of the braking resistor in relation to a cycle duration TD ≤ 120 s.2) When connected in parallel, the load capacity and trip current are doubled.

BW...-T / BW...-P

Connection cross section for signal contact 1 x 2.5 mm2

Switching capability of the thermostat’s signal contact • DC 2 A / DC 24 V (DC11)• AC 2 A / AC 230V (AC11)

Switch contact (NC) according to EN 61800-5-1

Page 48: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

48 Catalog – MOVITRAC® LTP

4 Braking resistors Accessories

Dimension drawing braking resistors BW... / BW...-T / BW...-P

60021BXX

BW... :• 1 = Flat design

The connecting lead is 500 mm (19.7 in) long. The scope of delivery includes four M4 stud bolts each of type 1 and 2.

• 2 = Grid resistor• 3 = Wire resistor• 4 = Wire resistor with

temperature switch (-T/-P)Cable entry (X) is possible from both sides.

Type BW... Mounting position

Main dimensions mm (in) Fastening parts mm (in) Cable gland Weight kg (lb)

BW..-T/ BW...-P A/A’ B C a b/c dBW106-T 2 795 (31.3) 270 (10.6) 490 (19.3) 770 (30.3) 380 (15) 10.5 (0.41) - 32 (71)BW206-T 2 995 (39.2) 270 (10.6) 490 (19.3) 970 (38.2) 380 (15) 10.5 (0.41) - 40 (88)BW012-025 2 295 (11.6) 260 (10.2) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) M12 + M25 8.0 (18)

BW012-025-P 2 295/355(11.6/14) 260 (10.2) 490 (19.3) 270 (10.6) 380 (15) 10.5 (0.41) M12 + M25 8.0 (18)

BW012-050-T 2 395 (15.6) 260 (10.2) 490 (19.3) 370 (14.6) 380 (15) 10.5 (0.41) - 12 (26)BW012-100-T 2 595 (23.4) 270 (10.6) 490 (19.3) 570 (22.4) 380 (15) 10.5 (0.41) - 21 (46)BW027-006 3 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9)BW027-012 3 486 (19.1) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG11 4.3 (9.5)BW039-003 3 286 (11.3) 120 (4.72) 92 (3.6) 230 (9.06) 64 (2.5) 6.5 (0.26) PG11 1.5 (3.3)BW039-006 3 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9)BW039-012 3 486 (19.1) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG11 4.3 (9.5)BW039-012-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11)BW039-026-T 4 649 (25.6) 120 (4.72) 275 (10.8) 530 (20.9) 240 (9.45) 6.5 (0.26) M12 + M25 7.5 (17)BW039-050-T 2 395 (15.6) 260 (10.2) 490 (19.3) 370 (14.6) 380 (15) 10.5 (0.41) - 12 (26)BW147 3 465 (18.3) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG13.5 4.3 (9.5)BW147-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11)BW247 3 665 (26.2) 120 (4.72) 185 (7.28) 626 (24.6) 150 (5.91) 6.5 (0.26) PG13.5 6.1 (13)BW247-T 4 749 (29.5) 120 (4.72) 185 (7.28) 626 (24.6) 150 (5.91) 6.5 (0.26) M12 + M25 9.2 (20)BW347 3 670 (26.4) 145 (5.71) 340 (13.4) 630 (24.8) 300 (11.8) 6.5 (0.26) PG13.5 13.2 (29.1)BW347-T 4 749 (29.5) 210 (8.27) 185 (7.28) 630 (24.8) 150 (5.91) 6.5 (0.26) M12 + M25 12.4 (27.3)BW168 3 365 (14.4) 120 4.72) 185 (7.28) 326 (12.8) 150 (5.91) 6.5 (0.26) PG13.5 3.5 (7.7)BW168-T 4 449 (17.7) 120 (4.72) 185 (7.28) 326 (12.8) 150 (5.91) 6.5 (0.26) M12 + M25 3.6 (7.9)BW268 3 465 (18.3) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) PG13.5 4.3 (9.5)BW268-T 4 549 (21.6) 120 (4.72) 185 (7.28) 426 (16.8) 150 (5.91) 6.5 (0.26) M12 + M25 4.9 (11)BW072-003 1 110 (4.33) 80 (3.1) 15 (0.59) 98 (3.9) 60 (2.4) – - 0.3 (0.7)BW072-005 1 216 (8.5) 80 (3.1) 15 (0.59) 204 (8.03) 60 (2.4) – - 0.6 (1)BW100-005 1 216 (8.5) 80 (3.1) 15 (0.59) 204 (8.03) 60 (2.4) – - 0.6 (1)BW100-006 4 486 (19.1) 120 (4.72) 92 (3.6) 430 (16.9) 64 (2.5) 6.5 (0.26) PG11 2.2 (4.9)BW100-006-T 4 549 (21.6) 120 (4.72) 92 (3.6) 430 (16.9) 80 (3.1) 6.5 (0.26) M12 + M25 3.0 (6.6)

b10

12

1 2

M4

43

CBA

2

a 10d

cA C

B

ac

d

B

C A

A'

A

a M25

M12C

X

c 8

B

Page 49: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 49

4 Line chokesAccessories

4.2 Line chokesLine chokes reduce supply harmonic distortion and protect MOVITRAC® LTP unitsagainst harmful supply disturbances. They are also used to reduce the effects of theMOVITRAC® LTP upon supply harmonic distortion.

Line chokes are also used to protect the power input circuits of the MOVITRAC® LTPagainst voltage spikes which might originate from lightening strikes or other equipmenton the same supply.The following units have built-in DC chokes and therefore do not require an externalchoke:• 240 V, sizes 4 – 6• 480 V, sizes 4 – 6• 575 V, size 3

4.2.1 Technical data

54801AXX 54886AXX

L L’

H

B

N2N1

D

L

Type Part number

MOVITRAC® LTP Size

Rated voltage [V]

Phase Rated current [A]

Inductance / limb [mH]

ND LT 010 290 211)

1) Not UL-approved

18201644 1 <230 1 10 2.9

ND LT 025 110 211) 18201652 2 <230 1 25 1.1

ND LT 006 480 531) 18201660 1 <600 3 6 4.8

ND LT 010 290 531) 18201679 2 <600 3 10 2.9

ND LT 036 081 531) 18201687 3 <600 3 36 0.81

ND LT 016 183 21-55 18217680 1 <230 1 16 1.83

ND LT 025 117 21-55 18217699 2 <230 1 25 1.17

ND LT 006 613 63-55 18217702 1 <600 3 6 4.8

ND LT 010 386 63-55 18217710 2 <600 3 10 3.86

ND LT 020 183 63-55 18217729 3 <600 3 18 2.04

Page 50: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

50 Catalog – MOVITRAC® LTP

4 Line chokes Accessories

4.2.2 Dimensions

Type L B H N1 N2 D Mass

[mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [kg] [lb]

ND LT 010 290 21 66 2.60 80 3.15 70 2.76 50 1.97 51 2.01 5 × 8 0.2 × 0.32

0.8 1.76

ND LT 025 110 21 85 3.35 95 3.74 95 3.74 64 2.52 59 2.32 5 × 8 0.2 × 0.32

1.8 3.97

ND LT 006 480 53 95 3.74 56 2.20 107 4.21 56 2.20 43 1.69 5 × 9 0.2 × 0.35

1.3 2.87

ND LT 010 290 53 125 4.92 71 2.80 127 5.00 100 3.94 55 2.17 5 × 8 0.2 × 0.32

2.5 5.51

ND LT 036 081 53 155 6.10 77 3.03 185 7.28 130 5.12 72 2.83 8 × 12

0.3 × 0.47

7.2 15.87

ND LT 016 183 21 55 82 3.23 70 2.76 70 2.76 70 2.76 58 2.28 6 0.24 1.0 2.20

ND LT 025 117 21 55 90 3.54 84 3.31 75 2.95 84 3.31 72 2.84 6 0.24 1.3 2.87

ND LT 006 613 63 55 115 4.53 74 2.91 88 3.46 80 3.15 60 2.36 5.5 × 7

0.22 × 0.28

1.6 3.53

ND LT 010 386 63 55 175 6.89 99 3.90 137 5.39 130 5.12 79 3.11 5.5 × 12

0.22 × 0.47

3.5 7.72

ND LT 020 183 63 55 175 6.89 114 4.49 137 5.39 130 5.12 94 3.70 5.5 × 12

0.22 × 0.47

7 15.43

Page 51: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 51

4 Output chokesAccessories

4.3 Output chokesOutput chokes improve the quality of the output waveform. Therefore the maximumcable length stated in the rating table can be doubled when using an output choke.

MOVITRAC® LTP units, like the majority of other inverter drives, have unfiltered outputs.In the majority of applications this will give satisfactory performance, however, in a smallnumber of applications output filtering is strongly recommended to improve system func-tionality, reliability and longevity. These applications include:• Long motor cables, up to 300 m (the rated cable length can be doubled if an output

choke is used)• High capacitance motor cables (i.e. typical "pyro" wire, used for fire protection)• Multiple motors connected in parallel• Motors without inverter grade insulation (typically older motors)

A range of high quality output chokes are available for MOVITRAC® LTP with thefollowing key features:• Limits output voltage gradient, typically < 200 V/µs• Limits transient over voltages at the motor terminals, typically < 1000 V• Suppression of mains conducted interference in lower frequency ranges• Compensation of capacitive load currents• Reduction of RFI emissions from the motor cable• Reduction of motor losses and audible noise caused by ripple

64757AXX

Page 52: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

52 Catalog – MOVITRAC® LTP

4 Output chokes Accessories

4.3.1 Technical Data

Comparison of output voltage and current characteristics

Without choke

With choke

Type Part number IP-protection Size Phase Rated voltage [V]

Rated current

[A]

Inductance / Limb [mH]

HD LT 008 200 53 1820 1695

IP00

1

3

480 8 2

HD LT 012 130 53 1820 1709 2 480 12 1.3

HD LT 030 050 53 1820 1717 3 480 18 0.5

HD LT 075 022 53 1820 1725 4 600 75 0.22

HD LT 180 009 53 1820 1733 5 600 180 0.09

HD LT 250 007 53 1820 1741 6 600 250 0.065

HD LT 008 200 63 55 1821 6757

IP55

1 480 – 600 8 2

HD LT 012 120 63 55 1821 6765 2 480 – 600 12 1.2

HD LT 018 090 63 55 1821 6773 3 480 – 600 18 0.9

64148AXX

64146AXX

1[V]

[A]

1

2

2

1[V]

[A]

1

2 2

NOTEWith a filter fitted the switching pulse rises slower and to a lower amplitude.

Page 53: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 53

4 Output chokesAccessories

4.3.2 Dimensions

64032AXX

L1

L2

L3

L1’

L2’

L3’

PE PE’

[1] [2]

N2B

N1

L

H

ØD

Type L B H N1 N2 ∅ D Weight

[mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] [kg] [lb]

HD LT 008 200 53 100 3.94 90 3.54 75 2.95 60 2.36 48 1.89 4 0.16 1.5 3.31

HD LT 012 130 53 125 4.92 115 4.53 85 3.35 100 3.94 55 2.17 5 0.20 3 6.61

HD LT 030 050 53 155 6.10 160 6.30 105 4.13 130 5.12 57 2.24 8 0.32 4.5 9.92

HD LT 075 022 53 190 7.48 255 10.04 125 4.92 170 6.69 68 2.68 8 0.32 10 22.04

HD LT 180 009 53 240 9.45 310 12.20 155 6.10 190 7.48 106 4.17 11 0.43 22 48.5

HD LT 250 007 53 300 11.81 390 15.35 210 8.27 240 9.45 121 4.76 11 0.43 40 88.18

HD LT 008 200 63 55 115 4.53 74 2.91 85 3.35 80 3.15 60 2.36 5.5 × 7 0.22 ×0.28

1.7 3.75

HD LT 012 120 63 55 140 5.51 87 3.43 110 4.33 100 3.94 70 2.76 5.5 × 7 0.22 ×0.28

3.2 7.05

HD LT 018 090 63 55 140 5.51 87 3.43 110 4.33 100 3.94 70 2.76 5.5 × 7 0.22 ×0.28

3.2 7.05

Page 54: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

54 Catalog – MOVITRAC® LTP

4 DIN rail mounting kit Accessories

4.4 DIN rail mounting kitA mounting kit is available to fit the MOVITRAC® LTP onto a DIN rail.

4.5 Remote keypad option LT BG-00Part number: 1820 8649The basic version of the MOVITRAC® LTP has an integrated keypad for some applica-tions, however it is necessary to have an additional keypad in a remote area. The key-pad option comes with a self-adhesive seal and a 3 m long cable to be plugged into theRJ11 connector on the MOVITRAC® LTP unit. The maximum cable length between thekeypad and the drive is 25 m for unshielded cable and 100 m for shielded cable.

Type Part number MOVITRAC® LTP Size

FH LT DINHS 01 18201776 1

FH LT DINHS 02 18201784 2

54888AXX

60201AXX

Page 55: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 55

4 Remote keypad option LT BG-00Accessories

4.5.1 Installation in switch cabinet door or control panel

To install LT BG-00 in the door of a switch cabinet or in a control panel the metal workhas to be cut according to the drawing below. By using the included self-adhesive sealthe installed keypad meets the IP54/NEMA 13 standard.

Up to 2 keypads can be installed in a drive network. In this case each drive must havea different address. The 2 keypads can then monitor and control parameters on thesame drive or on different drives. The overall cable length in the network must notexceed 25 m for unshielded cable or 100 m for shielded cable.

Dimension Drawing Switch cabinet mounting cut out

60245AXX 60246AXX

ca

e

d

f

b

g

h

[1]

[a] 81 mm [f] 3 mm

[b] 66 mm [g] 70 mm

[c] 65 mm [h] 55 mm

[d] 21 mm [1] Cut out

[e] 55 mm

60247AXX

Page 56: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

56 Catalog – MOVITRAC® LTP

4 Cable splitter 1 in and 2 out Accessories

4.6 Cable splitter 1 in and 2 outPart number: 18208681The cable splitter LT-RJ-CS-21 is required if the keypad is used in a drive network.

4.7 Prefabricated cables with RJ11 connectorThe prefabricated cables are available in 3 different lengths. Each cable is equipped witha 6-pin RJ11 connector on each end.

60202AXX

Cable length Type Part number

0.3 m unshielded LT K-RJ-003 1820 8657

1.0 m unshielded LT K-RJ-010 1820 8665

3.0 m unshielded LT K-RJ-030 1820 8673

Page 57: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 57

4 Interface adapter option UWS11AAccessories

4.8 Interface adapter option UWS11APart number: 822689XThe UWS11A converts RS-232 signals, for example from the PC, into RS-485 signals.These signals can then be routed to the RJ11 connector on the MOVITRAC® LTP unit.The USW11A requires a DC 24 V voltage supply (Imax = 100 mA). There is no prefabri-cated cable available for the RS-485 interface.

The UWS11A is mounted on a support rail (EN 50022-35 x 7.5) in the control cabinet.

RS-232 interface The connection between the USW11A and PC is made using a commercially avail-able serial interface shielded cable.

RS-485 interface A maximum of 64 MOVITRAC® LTP units can be networked for communication via the RS-485 interface of the USW11A. The maximum length of the shielded cable is 100 m.Dynamic terminating resistors are permanently installed, so do not connect any external terminating resistors.Permitted line cross section: • 1 core per terminal 0.20 – 2.5 mm2 (AWG 24 – 12).• 2 cores per terminal 0.20 – 1 mm2 (AWG 24 – 17).

01219CXXFigure 3: UWS11A dimension drawing (mm)

22.5

75

5 86

83

12345

24V

RS+RS-

12345

X1:

RS

-485

X2:

RS

-232

UWS

Page 58: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

58 Catalog – MOVITRAC® LTP

4 Interface adapter option LT-W-USB-RJ11 Accessories

4.9 Interface adapter option LT-W-USB-RJ11Part number: 18208703The LT-W-USB-RJ11 option converts USB signals, for example from the PC intoRS-485 signals. These RS-485 signals can then be routed to the RJ11 connector on theMOVITRAC® LTP unit.

The LT-W-USB-RJ11 option comes with cables, LTP shell CD and software CD for theinterface.

60203AXX

RS-485 interface A maximum of 63 MOVITRAC® LTP units can be networked for communication via the RS-485 interface of the LT-W-USB-RJ11. The maximum length of the shielded cable is 100 m.

Page 59: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 59

4 Second relay outputAccessories

4.10 Second relay output

The 2nd relay output module can be used in applications where the analog output fromthe drive is converted to a relay output.Typical applications are where 2 relay outputs are required. The functions of the relaysare programmable in the drive and can be any of the following:• Drive enabled• Drive healthy• Drive at set speed• Drive at zero speed• Drive at maximum speed• Motor in overload

Type Part number

OB LT 2ROUT 1822 3168

64746AXX 64759AXX

Terminal no.

Signal Connection Description

1 +24 V +24 V ref out Ref. to activate DI1 – DI3 (100 mA max.)

2 DI 1 Digital input 1 Positive logic"Logic 1" input voltage range: DC 8 – 30 V"Logic 0" input voltage range: DC 0 – 2 VCompatible with PLC requirement when 0 V is connected.

3 DI 2 Digital input 2

4 DI 3 Digital input 3 / thermistor contact

5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 mA max., 1 kΩ min.)

6 AI / DI Analog input (12 bit)Digital input 4

0 – 10 V, 0 – 20 mA, 4 – 20 mA"Logic 1" input voltage range: DC 8 – 30 V

7 0 V 0 V common 0 V ref for analog input (pot supply –)

8 Relay 2 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)

9 Relay 2 common Relay common

10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)

11 Relay 1 common Relay common

1 2 3 4 5 6 7 8 9 10 11

Page 60: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

60 Catalog – MOVITRAC® LTP

4 Second relay output Accessories

Specification

NOTEOnce this option board has been installed and fully wired into an IP55 / NEMA 12 drive,the board must be bent slightly in a downwards direction to enable the front cover to beclosed. This does not affect the function of the option board.

Max. relay switching voltage AC 250 V / DC 220 V

Max. relay switching current 1 A

Conformity IP00, UL94V-0

Environmental –10 – +50 °C

Dimensions [mm] 56 × 24 (not pins) × 14

[in] 2.20 × 0.98 (not pins) × 0.56

Page 61: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 61

4 Third relay outputAccessories

4.11 Third relay output

This plug-in output module provides 2 additional relay outputs. Relay 1 and 2 can be pro-grammed via parameters. The third relay output is fixed to represent "Drive healthy" or"Drive tripped", depending on whther the N.C. or N.O. contacts are used.

Type Part number

LT 3RO 00A 1820 8762

65047AXX 64760AXX

Terminal no.

Signal Connection Description

1 +24 V +24 V ref out Ref. to activate DI1 – DI3 (100 mA max.)

2 DI 1 Digital input 1 Positive logic"Logic 1" input voltage range: DC 8 – 30 V"Logic 0" input voltage range: DC 0 – 2 VCompatible with PLC requirement when 0 V is connected.

3 DI 2 Digital input 2

4 DI 3 Digital input 3 / thermistor contact

5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 mA max., 1 kΩ min.)

6 AI / DI Analog input (12 bit)Digital input 4

0 – 10 V, 0 – 20 mA, 4 – 20 mA"Logic 1" input voltage range: DC 8 – 30 V

7 0 V 0 V common 0 V ref for analog input (pot supply –)

8 Relay 2 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)Programmable in drive (P2-11)9 Relay 2 common Relay common

10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)Programmable in drive (P2-13)11 Relay 1 common Relay common

12 Relay 3 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)"Drive healthy" or "Drive tripped". Enabled when P2-01 = 20, 21 or 22.13 Relay 3 contact Relay contact

13 Relay 3 common Relay common

1 2 3 4 5 6

12 13 14

7 8 9 10 11

NOTEOnce this option board has been installed and fully wired into an IP55 / NEMA 12 drive,the board must be bent slightly in a downwards direction to enable the front cover to beclosed. This does not affect the function of the option board.

Page 62: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

62 Catalog – MOVITRAC® LTP

4 Third relay output Accessories

Specification

Max. relay switching voltage AC 250 V / DC 220 V

Max. relay switching current 1 A

Conformity IP00, UL94V-0

Environmental –10 – +50 °C

Dimensions [mm] 56 × 24 (not pins) × 14

[in] 2.20 × 0.98 (not pins) × 0.56

Page 63: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 63

4 Two indicator relayAccessories

4.12 Two indicator relay

The HVAC relay option module can be used in applications where 2 indicators arerequired showing "drive running" and "drive tripped".

Type Part number

OB LT HVAC-B 1821 8180

64748AXX 64760AXX

Terminal no.

Signal Connection Description

1 +24 V +24 V ref out Ref. to activate DI1 – DI3 (100 mA max.)

2 DI 1 Digital input 1 Positive logic"Logic 1" input voltage range: DC 8 – 30 V"Logic 0" input voltage range: DC 0 – 2 VCompatible with PLC requirement when 0 V is connected.

3 DI 2 Digital input 2

4 DI 3 Digital input 3 / thermistor contact

5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 mA max., 1 kΩ min.)

6 AI / DI Analog input (12 bit)Digital input 4

0 – 10 V, 0 – 20 mA, 4 – 20 mA"Logic 1" input voltage range: DC 8 – 30 V

7 0 V 0 V common 0 V ref for analog input (pot supply –)

8 AO / DO Analog output (10 bit)Digital output

0 – 10 V, 20 mA analog24 V / 20 mA digital

9 0 V 0 V common 0 V ref for analog output

10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)

11 Relay 1 common Relay common

12 Relay 2 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)

13 Relay 2 common Relay common

1 2 3 4 5 6

12 13

7 8 9 10 11

NOTEOnce this option board has been installed and fully wired into an IP55 / NEMA 12 drive,the board must be bent slightly in a downwards direction to enable the front cover to beclosed. This does not affect the function of the option board.

Page 64: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

64 Catalog – MOVITRAC® LTP

4 Two indicator relay Accessories

Specification

Max. relay switching voltage AC 250 V / DC 220 V

Max. relay switching current 1 A

Conformity IP00, UL94V-0

Environmental –10 – +50 °C

Dimensions [mm] 56 × 24 (not pins) × 14

[in] 2.20 × 0.98 (not pins) × 0.56

Page 65: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 65

4 Converter cardAccessories

4.13 Converter card

The converter card allows the digital inputs of the drive to be controlled directly from a110 V or 240 V control supply without the need for interfacing relays.

Type Part number Description

OB LT VCON A 1821 7672 110 V / 24 V converter

OB LT VCON B 1822 1947 240 V / 24 V converter

NOTEThe existing analog input can still be used by connecting the analog signal input onterminal 6. All other inputs and outputs to the drive are not affected.The digital input terminals are optically isolated from the remaining terminals and thedrive terminals.

64748AXX 64760AXX

Terminal no.

Signal Connection Description

1 Neutral Neutral Must not be connected to 0 V

2 DI 1 Digital input 1 AC 80 – 250 V, 68 k impedance

3 DI 2 Digital input 2

4 DI 3 Digital input 3

5 +10 V +10 V ref out 10 V ref for analog input (pot supply +, 10 mA max., 1 kΩ min.)

6 AI / DI Analog input (12 bit)Digital input 4

0 – 10 V, 0 – 20 mA, 4 – 20 mA"Logic 1" input voltage range: DC 8 – 30 V

7 0 V 0 V common 0 V ref for analog input (pot supply –)

8 AO / DO Analog output (10 bit)Digital output

0 – 10 V, 20 mA analog24 V / 20 mA digital

9 0 V 0 V common 0 V ref for analog output

10 Relay 1 contact Relay contact N.O. relay contact (AC 250 V / DC 30 V @ 5 A)

11 Relay 1 common Relay common

12 Neutral Neutral Must not be connected to 0 V

13 DI4 Digital input 4 AC 80 – 250 V, 68 k impedance

1 2 3 4 5 6

12 13

7 8 9 10 11

Page 66: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

66 Catalog – MOVITRAC® LTP

4 Converter card Accessories

Specification

NOTEOnce this option board has been installed and fully wired into an IP55 / NEMA 12 drive,the board must be bent slightly in a downwards direction to enable the front cover to beclosed. This does not affect the function of the option board.

Max. relay switching voltage AC 250 V / DC 220 V

Max. relay switching current 1 A

Conformity IP00, UL94V-0

Environmental –10 – +50 °C

Dimensions [mm] 56 × 24 (not pins) × 14

[in] 2.20 × 0.98 (not pins) × 0.56

Page 67: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 67

4 Local switchboardAccessories

4.14 Local switchboard

The local switchboard is an auxiliary way to enable and control the speed of the drivevia the input terminal block. The board has switches which are directly connected to thedigital inputs. The potentiometer is connected to the analog input.

Specification

Type Part number

OB LT LOCMO 1820 5607

NOTEThis option should only be used for test purposes. For field application a hard wire con-nection must be used to control the drive.

64770AXX 64771AXX

1 2 3 4 5 6 7 8 9 10 11

NOTEThe terminal connections on the local switchboard are the same as those on theMOVITRAC® LTP unit.

Conformity IP00, UL90V-0

Environmental –10 – +50 °C

Dimensions [mm] 56 × 33 (not pins) × 16

[in] 2.20 × 1.31 (not pins) × 0.64

Page 68: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

68 Catalog – MOVITRAC® LTP

4 Lock Accessories

4.15 Lock

The lock can be used to secure against unauthorised starting of the inverter. This optioncan be installed on all drives with switches in IP55 housing.

4.16 MC LTP CE, Pocket PC BG LT OWDCE

The BG LT OWDCE Pocket PC and the LTP Shell CE software provide a fast and effi-cient means of commissioning of the MOVITRAC® LTP, with the ability to upload anddownload parameters, save drive parameters to a file, export drive parameters to Micro-soft Word, control of the drive and monitor status of motor and inputs/outputs.

Type Part number

LZ LOCK1-A 1821 7745

65198AXX 65207AXX

Type Part number

MC LTP CE 1820 1792

60392AXX

Page 69: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 69

4 Fieldbus CommunicationAccessories

4.17 Fieldbus CommunicationFieldbus communication can be realized through a high speed communication networkvia a gateway.

4.17.1 Technical specifications

65048AXX

Size 120 × 75 × 27 mm

4.72 × 2.95 × 1.06 inches

Power supply 24 V ±10 % consumption:Max. 280 mA on 24 V, typically 100 mA

Operational ambient temperature range 0 °C – +55 °C

Storage ambient temperature range –5 °C – +85 °C

Mounting DIN-rail, PE via DIN-rail

Protection rating cabinet drive IP20

EMC Certification CE marked, UL & cUL conformance

Conformance Tested and verified for fieldbus conformance

Type Part number Network type Comprises Default no. of drives

Max. no. of drives

LT FP 00A 1820 8819 PROFIBUS DP PROFIBUS gateway with RJ11 - 9 way D type & RJ45 - 9 way D type data cables

4 8

LT FD 00A 1820 8711 DeviceNet DeviceNet gateway with RJ11 - 9 way D type & RJ45 - 9 way D type data cables

4 4

Thilini-Envy
Typewritten Text
NOTE
Thilini-Envy
Typewritten Text
Configuration files for all gateway types can be downloaded from the SEW-EURODRIVE website.
Page 70: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

70 Catalog – MOVITRAC® LTP

5 Project planning flowchart Select a motor

5 Select a motor5.1 Project planning flowchart

Specify– Technical data and environmental conditions– Peripheral conditions– System interfacing

Calculation of the relevant application data– Static, dynamic and regenerative power– Speed

Gear unit selection– Definition of gear unit size, gear unit reduction ratio and gear unit type– Check for gear unit utilization (Ma max ≥ Ma (t))

Motor selection– Torque and speed reduced to the motor shaft– Determining the motor

Checking– Max. torque demand < 1.5 × MN– Required motor speed < nN– Thermal load taking into account range and duty cycle

Selecting the MOVITRAC® LTP frequency inverter– Assignment of motor and inverter– Continuous power, peak power– Installation conditions

Accessories / Options– EMC measures (NF, ND, HD)– 2ROUT, converter card– DIN rail mounting

Make sure that all requirements have been met.

Pi

fkVA

Hz

n

Page 71: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 71

5 Inverter → motor combinationsSelect a motor

5.2 Inverter → motor combinationsThe tables below are an extract from the SEW-EURODRIVE catalogs for gearmotors.

5.2.1 Motors for 200 V – 400 V, 50 / 60 Hz connection (DR)

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2B1 1-x0

DRS71S4 0.37 0.5 1380 0004

DRS71S4 (60 Hz) 0.37 0.5 1700 0004

DRS71M4 0.55 0.75 1360 0008

DRS71M4 (60 Hz) 0.55 0.75 1700 0008

DRS80S4 0.75 1 1380 0008

DRS80S4 (60 Hz) 0.75 1 1700 0008

DRS90M4 1.5 2 1410 0015

DRS90M4 (60 Hz) 1.5 2 1720 0015

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2B1 4-x0

DRS80M4 1.1 1.5 1400 0015

DRS80M4 (60 Hz) 1.1 1.5 1740 0015

DRS90M4 1.5 2 1410 0015

DRS90M4 (60 Hz) 1.5 2 1720 0015

DRS90L4 2.2 3 1410 0022

DRS90L4 (60 Hz) 2.2 3 1720 0022

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2A3 4-x0

DRS100M4 3 4 1400 0030

DRS100M4 (60 Hz) 3 4 1740 0030

DRS100LC4 4 5.4 1420 0040

DRS100LC4 (60 Hz) 4 5.4 1420 0040

DRS132S4 5.5 7.5 1430 0055

DRS132S4 (60 Hz) 5.5 7.5 1720 0055

DRS132M4 7.5 10 1430 0075

DRS132M4 (60 Hz) 7.5 10 1740 0075

DRS160M4 11 15 1460 0110

DRS160M4 (60 Hz) 11 15 1760 0110

DRS160MC4 15 20 1470 0150

DRS160MC4 (60 Hz) 15 20 1770 0150

DRS180M4 18.5 25 1465 0185

DRS180M4 (60 Hz) 18.5 25 1775 0185

DRS180L4 22 30 1465 0220

DRS180L4 (60 Hz) 22 30 1770 0220

Pi

fkVA

Hz

n

Page 72: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

72 Catalog – MOVITRAC® LTP

5 Inverter → motor combinations Select a motor

5.2.2 Motors for 200 V – 240 V, 50 / 60 Hz connection (DT / DV)

DRS180LC4 30 35 1470 0300

DRS180LC4 (60 Hz) 30 35 1770 0300

DRS225S4 37 50 1475 0370

DRS225S4 (60 Hz) 37 50 1780 0370

DRS225M4 45 60 1478 0450

DRS225M4 (60 Hz) 45 60 1780 0450

DRS225MC4 55 75 1480 0550

DRS225MC4 (60 Hz) 55 75 1780 0550

DRS225MC4 75 100 1480 0750

DRS225MC4 (60 Hz) 75 100 1780 0750

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2A3 4-x0

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2B1 1-00

DT71D4 0.37 0.5 1380 0004

DT71D4 NEMA 0.37 0.5 1700 0004

DT80K4 0.55 0.75 1360 0008

DT80K4 NEMA 0.55 0.75 1700 0008

DT80N4 0.75 1 1380 0008

DT80N4 NEMA 0.75 1 1700 0008

DT90L4 1.5 2 1410 0015

DT90L4 NEMA 1.5 2 1720 0015

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2B1 4-x0

DT90S4 1.1 1.5 1400 0015

DT90S4 NEMA 1.1 1.5 1740 0015

DT90L4 1.5 2 1410 0015

DT90L4 NEMA 1.5 2 1720 0015

DV100M4 2.2 3 1410 0022

DT100LS4 NEMA 2.2 3 1720 0022

Pi

fkVA

Hz

n

Page 73: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 73

5 Inverter → motor combinationsSelect a motor

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -2A3 4-x0

DV100L4 3 4 1400 0030

DT100LS4 NEMA 2.2 3 1720 0030

DV112M4 4 5.4 1420 0040

DT100L4 NEMA 3.7 5 1680 0040

DV132S4 5.5 7.5 1430 0055

DV132S4 NEMA 5.5 7.5 1720 0055

DV132M4 7.5 10 1430 0075

DV132M4 NEMA 7.5 10 1740 0075

DV160M4 11 15 1440 0110

DV160M4 NEMA 11 15 1740 0110

DV160L4 15 20 1460 0150

DV160L4 NEMA 15 20 1760 0150

DV180M4 18.5 25 1465 0185

DV180M4 NEMA 18.5 25 1760 0185

DV180L4 22 30 1465 0220

DV180L4 NEMA 22 30 1760 0220

DV200L4 30 40 1470 0300

DV200L4 NEMA 30 40 1760 0300

DV225S4 37 50 1470 0370

DV225S4 NEMA 37 50 1760 0370

DV225M4 45 60 1470 0450

DV225M4 NEMA 45 60 1760 0450

DV250M4 55 75 1475 0550

DV250M4 NEMA 55 75 1775 0550

DV280S4 75 100 1480 0750

DV280S4 NEMA 75 100 1780 0750

Pi

fkVA

Hz

n

Page 74: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

74 Catalog – MOVITRAC® LTP

5 Inverter → motor combinations Select a motor

5.2.3 Motors for 380 V – 480 V, 50 / 60 Hz connection (DR)

SEW-EURODRIVE Motor type

Motorpower Motor rated speed[min–1]

Inverter type

[kW] [hp] MC LTP ......... -5A3 4-00

DRS80S4 0.75 1.0 1380 0008

DRS80S4 (60 Hz) 0.75 1.0 1700 0008

DRS80M4 1.1 1.5 1400 0015

DRS80M4 (60 Hz) 1.1 1.5 1740 0015

DRS90M4 1.5 2.0 1410 0015

DRS90M4 (60 Hz) 1.5 2.0 1720 0015

DRS90L4 2.2 3.0 1410 0022

DRS90L4 (60 Hz) 2.2 3.0 1720 0022

DRS100LC4 4.0 5.4 1420 0040

DRS100LC4 (60 Hz) 4.0 5.4 1730 0040

DRS132S4 5.5 7.5 1430 0055

DRS132S4 (60 Hz) 5.5 7.5 1720 0055

DRS132M4 7.5 10.0 1430 0075

DRS132M4 (60 Hz) 7.5 10.0 1740 0075

DRS160M4 11 15.0 1460 0110

DRS160M4 (60 Hz) 11 15.0 1760 0110

DRS160MC4 15 20.0 1470 0150

DRS160MC4 (60 Hz) 15 20.0 1770 0150

DRS180L4 22 30.0 1465 0220

DRS180L4 (60 Hz) 22 30.0 1770 0220

DRS180LC4 30 35.0 1470 0300

DRS180LC4 (60 Hz) 30 35.0 1770 0300

DRS225M4 45 60.0 1478 0450

DRS225M4 (60 Hz) 45 60.0 1780 0450

DRS225MC4 55 75.0 1480 0550

DRS225MC4 (60 Hz) 55 75.0 1780 0550

DRS315S4 132 175.0 1484 1320

DRS315S4 (60 Hz) 132 175.0 1784 1320

DRS315M4 160 210.0 1483 1600

DRS315M4 (60 Hz) 160 210.0 1783 1600

DRS315L4 200 250.0 1481 2000

DRS315L4 (60 Hz) 200 250.0 1781 2000

Pi

fkVA

Hz

n

Page 75: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 75

5 Inverter → motor combinationsSelect a motor

5.2.4 Motors for 380 V – 480 V, 50 / 60 Hz connection (DT / DV)

SEW-EURODRIVE Motor type

Motor power Motor rated speed[min–1]

Inverter type

[kW] [hp]MC LTP A .... -5A3 4-00

DT80N4 0.75 1 1380 0008

DT80N4 NEMA 0.75 1 1700 0008

DT90L4 1.5 2 1410 0015

DT90L4 NEMA 1.5 2 1720 0015

DV100M4 2.2 3 1410 0022

DT100LS4 NEMA 2.2 3 1720 0022

DV112M4 4 5.4 1420 0040

DT100L4 NEMA 3.7 5 1680 0040

DV132S4 5.5 7.5 1430 0055

DV132S4 NEMA 5.5 7.5 1720 0055

DV132M4 7.5 10 1430 0075

DV132M4 NEMA 7.5 10 1740 0075

DV160M4 11 15 1440 0110

DV16M4 NEMA 11 15 1740 0110

DV160L4 15 20 1460 0150

DV160L4 NEMA 15 20 1760 0150

DV180M4 18.5 25 1465 0185

DV180M4 NEMA 18.5 25 1760 0185

DV180L4 22 30 1465 0220

DV180L4 NEMA 22 30 1760 0220

DV200L4 30 40 1470 0300

DV200L4 NEMA 30 40 1760 0300

DV225S4 37 50 1470 0370

DV225S4 NEMA 37 50 1760 0370

DV225M4 45 60 1470 0450

DV225M4 NEMA 45 60 1760 0450

DV250M4 55 75 1475 0550

DV250M4 NEMA 55 75 1775 0550

DV280S4 75 100 1480 0750

DV280S4 NEMA 75 100 1780 0750

Pi

fkVA

Hz

n

Page 76: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

76 Catalog – MOVITRAC® LTP

5 Inverter → motor combinations Select a motor

5.2.5 Motors for 500 V – 600 V, 50 / 60 Hz connection (DR)

SEW-EURODRIVE Motor type

Motorpower Motor rated speed[min–1]

Inverter type

[kW] [hp] MC LTP ......... -603 4-00

DRS80S4 0.75 1.0 1380 0008

DRS80S4 (60 Hz) 0.75 1.0 1700 0008

DRS80M4 1.1 1.5 1400 0015

DRS80M4 (60 Hz) 1.1 1.5 1740 0015

DRS90M4 1.5 2.0 1410 0015

DRS90M4 (60 Hz) 1.5 2.0 1720 0015

DRS90L4 2.2 3.0 1410 0022

DRS90L4 (60 Hz) 2.2 3.0 1720 0022

DRS100LC4 4.0 5.4 1420 0040

DRS100LC4 (60 Hz) 4.0 5.4 1730 0040

DRS132S4 5.5 7.5 1430 0055

DRS132S4 (60 Hz) 5.5 7.5 1720 0055

DRS132M4 7.5 10.0 1430 0075

DRS132M4 (60 Hz) 7.5 10.0 1740 0075

DRS160M4 11 15.0 1460 0110

DRS160M4 (60 Hz) 11 15.0 1760 0110

DRS160MC4 15 20.0 1470 0150

DRS160MC4 (60 Hz) 15 20.0 1770 0150

DRS180L4 22 30.0 1465 0220

DRS180L4 (60 Hz) 22 30.0 1770 0220

DRS180LC4 30 35.0 1470 0300

DRS180LC4 (60 Hz) 30 35.0 1770 0300

DRS225M4 45 60.0 1478 0450

DRS225M4 (60 Hz) 45 60.0 1780 0450

DRS225MC4 55 75.0 1480 0550

DRS225MC4 (60 Hz) 55 75.0 1780 0550

DRS315S4 132 175.0 1484 1320

DRS315S4 (60 Hz) 132 175.0 1784 1320

DRS315M4 160 210.0 1483 1600

DRS315M4 (60 Hz) 160 210.0 1783 1600

DRS315L4 200 250.0 1481 2000

DRS315L4 (60 Hz) 200 250.0 1781 2000

Pi

fkVA

Hz

n

Page 77: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

Catalog – MOVITRAC® LTP 77

Index

6 Index

A

Accessories.................................................... 42Cable splitter............................................ 56Cables with RJ11 connector .................... 56Converter card ......................................... 65Fieldbus communication .......................... 69Interface adapter option

LT-W-USB-RJ1158Interface adapter option UWS11A ........... 57Local switchboard .................................... 67Lock ......................................................... 68Remote keypad option LT BG-00 ............ 54Second relay output................................. 59Shell software .......................................... 68Third relay output..................................... 61Two indicator relay .................................. 63

Application environment................................... 5Auto-tune ....................................................... 34

B

Braking resistor tables.................................... 45Braking resistors ............................................ 42

Circuit ...................................................... 42Flat design ............................................... 44Minimum values....................................... 43Wire and grid resistors............................. 45

Braking resistors BW... / BW...-T / BW...-PAssignment to AC 230 V units ................. 45

C

Cable splitter .................................................. 56Cables with RJ11 connector .......................... 56Chokes

Dimensions of line chokes ....................... 50Dimensions of output chokes .................. 53Line chokes ............................................. 49Output chokes ......................................... 51Technical data for line chokes ................. 49Technical data for output chokes............. 52

CommunicationInfra-red ................................................... 27MODBUS network ................................... 26RS-485 .................................................... 26

Communication socket RJ11 ......................... 26Conformance.................................................. 19Converter card ............................................... 65Current ratings ................................................. 9

D

Degree of protection, braking resistors .......... 44Digital Input Function, P2-01.......................... 35Dimension drawings

Braking resistors BW... / BW...-T / BW...-P................................................. 48

Dimensions .................................................... 21Force-vented switch cabinet .................... 24IP20/NEMA 1 housing ............................. 21IP55/NEMA 12 housing ........................... 22Non-vented metal switch cabinet ............. 23Vented metal switch cabinet .................... 24

DIN rail mounting kit ....................................... 54

E

Environment, application.................................. 5Environmental data ........................................ 20Explanation of symbols .................................... 4Explosion-proof areas ...................................... 5Extended parameters ..................................... 29

F

Fieldbus communication ................................ 69

H

High performance motor control parameters.. 34

I

Important Notes................................................ 4Indicator relay................................................. 63Infra-red communication interface.................. 27Input voltage ranges......................................... 7Installation ........................................................ 6Interface adapter option

LT-W-USB-RJ11 ...................................... 58UWS11A .................................................. 57

IP20 housing, switch cabinet.......................... 23

K

Keypad ........................................................... 27

L

Line chokes .................................................... 49Dimensions .............................................. 50Technical data ......................................... 49

Local switchboard .......................................... 67Lock................................................................ 68

M

Motor and inverter selection ........................... 71200 V – 240 V, 50/60 Hz (DR) ................. 71200 V – 240 V, 50/60 Hz (DT/DV) ........... 72380 V – 480 V, 50/60 Hz (DR) ................. 74380 V – 480 V, 50/60 Hz (DT / DV) ......... 75500 V – 600 V, 50/60 Hz (DR) ................. 76

Motor selection............................................... 70

Page 78: SEW Eurodrive MOVITRAC LTP Inverters Catalog · 500 – 600 V ± 10 %, 3-phase, 50 … 60 Hz ± 5 % Products used with a 3-phase supply are designed for a maximum supply imbalance

78 Catalog – MOVITRAC® LTP

Index

O

Operation ......................................................... 6Output chokes ................................................ 51

Dimensions .............................................. 53Technical data ......................................... 52

Output power.................................................... 9Overload capability......................................... 19

P

ParametersExtended ................................................. 29High performance motor control

parameters........................................... 34P2-01 Digital Input Function .................... 35Real-time monitoring parameters ............ 41Specifications .......................................... 28Standard .................................................. 28User feedback control.............................. 33

Power, output ................................................... 9Product designation ......................................... 8Project planning flowchart .............................. 70Protection features......................................... 19

R

Rail mounting kit, DIN .................................... 54Remote keypad option LT BG-00................... 54

Installation in switch cabinet door / control panel ........................................ 55

RJ11 Communication socket ......................... 26

S

Safety Notes..................................................... 6Second relay output

Relay output, second ............................... 59Select a motor ................................................ 70Selection, motor and inverter ......................... 71Servicing .......................................................... 6Signal terminal connections ........................... 25Specifications................................................... 7Standard parameters ..................................... 28Startup ............................................................. 6Switch cabinet ................................................ 23

Dimensions of force-vented switch cabinet ................................................. 24

Dimensions of non-vented metal switch cabinet ................................................. 23

Dimensions of vented switch cabinet ...... 24Switchboard, local .......................................... 67Symbols, explanation ....................................... 4

T

Third relay outputRelay output, third ................................... 61

U

User feedback control parameters ................. 33User interface................................................. 27

V

Voltage ranges, input ....................................... 7

W

Waste disposal ................................................. 5