seismic isolation in highway bridges, slides 2012 by ian buckle

Upload: itetejac

Post on 15-Oct-2015

51 views

Category:

Documents


12 download

TRANSCRIPT

  • Seismic Isolation Technology forSeismic Isolation Technology for Highway Bridges

    _____________

    Ian Buckle Foundation Professor

    Department of Civil and Environmental Engineering

    1

    University of Nevada Reno, Reno NV 89557

  • Topics Background Principles of Seismic Isolation Some Applications System Design Testing Requirements

    Sources: FHWA/MCEER 2006, Seismic

    I l ti f Hi h B id S i lIsolation of Highway Bridges, SpecialPublication MCEER-06-SP07

    AASHTO 2010 Guide Specifications for

    2

    AASHTO 2010, Guide Specifications for Seismic Isolation Design, Third Edition

  • Topics

    BackgroundBackground Principles of Seismic Isolation

    S A li ti Some Applications System Design Testing Requirements

    3

  • Conventional Seismic Design

    Superstructure

    Ab t tBearingsAbutment Abutment

    ea gsAbutment

    Footing & piles

    Columns are required to support

    4

    Columns are required to support gravity and earthquake loads, dissipate energy, and not collapse

    EQ ground motion

  • Unacceptable Performance

    Collapsed Superstructure

    Ab t tBearings

    Ab t t

    Fractured Column

    Abutmentea gs

    Abutment

    Piles

    ColumnFooting

    Piles

    5

    EQ ground motion

  • Seismic Design Objective

    column strengthF t f f t 1 0Factor of safety =

    earthquake force> 1.0

    6

  • Seismic Design Objective

    capacityF t f f t 1 0Factor of safety = > 1.0

    demand

    7

  • Conventional Design ApproachINCREASE CAPACITY

    capacityF t f f t 1 0Factor of safety = > 1.0

    demand

    8

  • Conventional Design

    9

  • Conventional Design

    10

  • Seismic Isolation an Alternative

    capacityF t f f t 1 0Factor of safety = > 1.0

    demand

    REDUCE DEMAND

    11

  • Seismic Isolation an Alternative

    12

  • Seismic Isolation an Alternative

    IsolationIsolation suspension system

    13

    EQ ground motion

  • Basic Idea of Seismic IsolationIsolate the bridge from ground motion by:

    Inserting a flexible support system between the super- and sub-structure (isolation bearings). This will lengthen the natural period of the bridge such that the inertia forces in the bridgebridge such that the inertia forces in the bridge are significantly reduced.Force reduction may be sufficient to keepForce reduction may be sufficient to keep columns elastic.

    Control the liveliness of the bridge (due to the flexible bearings) using energy dissipators(dampers) to limit the motion

    14

    (dampers) to limit the motion.

  • Seismic Isolation: Key Point

    Seismic isolation reduces the earthquakedemand on a bridge, rather than increasesgits capacity.

    In many cases the reduction in demand is such that it may be feasible to have substructures perform elastically.

    15

  • Topics

    BackgroundBackground Principles of Seismic Isolation

    S A li ti Some Applications System Design Testing Requirements

    16

  • Principles of Seismic Isolation

    17

  • Principles of Seismic Isolation

    18

  • Principles of Seismic Isolation

    19

  • Principles of Seismic Isolation

    20

  • Principles of Seismic IsolationIn addition to flexibility and energy dissipation

    most isolation systems also comprise:y p Adequate rigidity for non-seismic loads

    (e g wind and braking) while(e.g. wind and braking) while accommodating thermal, creep, and other shortening effects andshortening effects, and

    Self-centering capability

    21

  • Seismic Isolation: Key Point

    Most seismic isolation systems comprise:1.Flexibility 2.Energy dissipation3.Rigidity for non-seismic loads g y4.Self-centering

    Above criteria means all isolation systems have nonlinear properties. exceptions exist

    22

    p p pbut are rare.

  • Principles of Seismic Isolation

    Isolator Force, F

    KdKisol

    Qd

    Fy Fisol

    Ku

    dy Ku

    disol Isolator Displacement, d Ku

    K = Elastic (unloading) stiffness

    Kd

    Qd = Characteristic strength

    23

    Ku Elastic (unloading) stiffnessKisol = Effective stiffnessdisol = Isolator lateral displacement

    d gFy = Yield strengthFisol = Isolator lateral forceKd = Post-elastic stiffness

  • Principles of Seismic Isolation

    POLISHED STAINLESS STEEL SURFACEPOLISHED STAINLESS STEEL SURFACE

    SEAL

    R

    SEAL

    R

    Lead-Rubber Isolator

    STAINLESS STEELARTICULATED SLIDER(ROTATIONAL PART)

    COMPOSITE LINER MATERIAL

    RSTAINLESS STEELARTICULATED SLIDER(ROTATIONAL PART)

    COMPOSITE LINER MATERIAL

    R

    Friction-Pendulum

    24

    Friction-Pendulum Isolator

  • Principles of Seismic Isolation

    Eradiquake Isolator

    25

  • Bridges Not Suitable for Isolation Bridges on soft sites, because lengthening

    the period may increase, rather than p y ,decrease, spectral accelerations

    Soft soilSoft soil spectrumRock

    spectrum

    26

  • Bridges Not Suitable for Isolation

    Bridges in high seismic zones on soft sites, g g ,where displacements may be large and costly expansion joints may be required to accommodate movements

    Bridges with tall flexible piers, which already have long periods and little advantage is

    i d ith i l tigained with isolation

    27

  • Seismic Isolation: Key Point

    Bridges that are most suitable for isolation are (a) located on stiff and medium-stiff soil

    sites, (b) have relatively stiff substructures

    (e.g. short-to-medium height columns)(c) continuous superstructures, and (d) seat-type abutments.

    28

  • Topics

    BackgroundBackground Principles of Seismic Isolation

    S A li ti Some Applications System Design Testing Requirements

    29

  • Applications: So. Rangitikei River, NZ

    30

  • Applications: US 101 Sierra Point, CA

    31

  • Applications: I-680 Benecia-Martinez, CAMartinez, CA

    32

  • Applications: JFK Airport Light Rail, NY

    33

  • Applications: Bolu Viaduct, Turkey

    34

  • Applications in U.S, Canada, Mexico

    Applications(Percent of total

    Isolator Type

    (Percent of total number of

    isolated bridges in Northin North

    America)

    Lead rubber isolator 75%Lead-rubber isolator 75%

    Eradiquake isolator 20%

    Other: Friction pendulum, High damping rubber, Natural Rubber FIP isolator

    5%

    35

    Rubber, FIP isolator

  • Topics

    BackgroundBackground Principles of Seismic Isolation

    S A li ti Some Applications System Design Testing Requirements

    36

  • Design of a Bridge Isolation SystemThree step process:

    1. Determine required performance criteriae e e equ ed pe o a ce c e a2. Determine properties of the isolation system

    (e.g. Qd and Kd) to achieve required ( g d d) qperformance using one or more methods of analysis V Kd

    3. Select isolator type and design hardware to achieve

    V KdQd

    required system properties (i.e.,Qd and Kd values) using

    D

    37

    d d

    a rational design procedure

  • Performance Criteria Usually set by owner Examples include:Examples include:

    o Not-to-exceed total base shear for Design Earthquake (DE)Earthquake (DE)

    o Elastic columns during DEo Not-to-exceed longitudinal displacement ino Not to exceed longitudinal displacement in

    superstructure during DE.o Essentially elastic behavior for the Maximumo Essentially elastic behavior for the Maximum

    Considered Earthquake (MCE)o Reparable damage in MCE, but not collapse

    38

    p g , p

  • Analysis Methods for Isolated BridgesBridges

    Bridges with nonlinear isolators may beBridges with nonlinear isolators may be analyzed using linear methods provided equivalent properties are used such asequivalent properties are used, such as effective stiffness and

    i l t i d i b d equivalent viscous damping based on the hysteretic energy dissipated by the i l tisolators.

    39

  • Analysis Methods

    Simplified MethodSimplified Method Single Mode Spectral Method

    M lti d S t l M th d Multimode Spectral Method Time History Method

    40

  • Simplified Method Assumptions1. Superstructure acts a rigid-diaphragm compared

    to flexibility of isolators2 Single displacement describes motion of2. Single displacement describes motion of

    superstructure, i.e. single degree-of-freedom systemy

    3. Nonlinear properties of isolators may be represented by bilinear loops

    V4. Bilinear loops can be represented by Kisol,

    ff i iff d

    V

    effective stiffness, and energy dissipated per cycle

    f l

    Kisol D

    41

    = area of loop Note Kisol & loop area are dependent on displacement, D.

  • Simplified Method Assumptions5. Energy dissipated per cycle may be

    represented by viscous damping, i.e., work done during plastic deformation can be represented by work done moving viscous fluid through an orifice Equivalent viscousfluid through an orifice. Equivalent viscous damping ratio given by

    )1(2

    isol

    y

    isol

    d

    dd

    FQh

    6. Acceleration spectrum is inversely i l i d (S / T)

    42

    proportional to period (SA = a / T)

  • Simplified Method Assumptions7. Acceleration spectra for 5% viscous

    damping may be scaled for actual damping (h%) by dividing by a damping coefficient, BL

    3.0

    050

    hBL 05.0 B is used in long period range of spectrumBL is used in long-period range of spectrum. A second factor (BS) is used in short-period range Isolated bridges fall in long period

    43

    range. Isolated bridges fall in long-period range.

  • AASHTO Design Response SpectraAASHTO Spectra (SA) are for 5% damping on a rock site (Site Class B)

    SA (A) Spectral Acceleration (g)5 % damping B)

    For sites other than rock, the spectra are modified by Site SD1 h % damping p yFactors, Fa and FvFor damping other than 5%, the

    Period T1.0s

    SD1 / BL

    spectra are modified by a Damping Factor, BL

    SSFAS Dv 11

    Period, T

    SD (D) Spectral Displacement5 % damping

    TBS

    TBSAS

    L

    D

    L

    vA

    11 TSTSFg

    10SD1

    5 % damping

    44

    L

    D

    L

    vD B

    TSB

    TSFgDS 112 79.94

    Period, T1.0s

    h % damping10SD1 / BL

  • Simplified MethodV

    This method is alsoV

    FisolQdKd

    known as the Direct-Displacement

    Kisol DDirect Displacement Method

    d i li bl t

    disol

    S (D) Spectraland is applicable toa wide range of

    SD (D) Spectral Displacement

    10S

    5 % damping

    structural types - not just isolated bridges.

    10SD1

    h % damping10SD1 / BL

    45

    just isolated bridges.Period, T1.0s

    p g10SD1 / BL

  • Simplified MethodBasic steps:1. Assume value for

    VFisolQd

    Kdisol2. Calculate effective Kisol

    D

    Kd

    stiffness, Kisol3. Calculate max. force,

    Ddisol

    Fisol4. Calculate effective

    i d Tperiod, Teff

    d KQK isoldKF ff WT 246

    disol

    isol KdK isolisolisol dKF

    isoleff gK

    T 2

  • Simplified Method Continued5. Calculate viscous

    damping ratio, hV

    FisolQdK6. Calculate damping

    coefficient, BL KisolD

    Kd

    7. Calculate disol8. Compare with value

    Ddisoldy

    for disol in Step (1). Repeat if necessary until convergence

    effL

    visol TB

    SFgd 124until convergence.

    )1(2 yddd

    FQh 3.0)

    050( hBL )(79.9 1 inchesTB

    SFd effvisol

    47

    isolisol dF )05.0(L B ffL

  • Example: Simplified Method

    The superstructure of a 2-span bridge weighs533 K It is located on a rock site where S =533 K. It is located on a rock site where SD1 = 0.55. The bridge is seismically isolated with 12 isolation bearings at the piers and12 isolation bearings at the piers and abutments.

    Isolation

    system

    48

  • Example

    If the value of Q = 0 075W andIf the value of Qd = 0.075W and Kd = 13.0 K/in (summed over all theisolators), calculate the maximumdisplacement of the superstructure and thetotal base shear.

    Neglect pier flexibility.

    49

  • Example 1Solution:1. Initialize

    1.1 Qd =0.075 W = 0.075 (533) = 40 K1 2 Need initial value di l1.2 Need initial value disol

    Take Teff = 1.5 sec, 5% damping (B =1 0) and calculate5% damping (BL=1.0) and calculate D = 9.79 SD1 Teff / BL

    9 79 (0 55) 1 5= 9.79 (0.55) 1.5 = 8.08 in

    50

    Take initial value for disol = D

  • Example 1 ContinuedSolution:1. Initialize

    Qd = 40 KD = 8 08 inD 8.08 in

    2 Iterate2. Iterate2.1 Set disol = D and proceed with Steps 1-7

    51

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol2. Effective stiffness, Kisol3. Max. isolator force, Fm4. Effective period, Teff 5. Viscous damping ratio, h%6 D i ffi i t B6. Damping coefficient, BL7. Isolator displacement, disol

    52

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol3. Max. isolator force, Fm4. Effective period, Teff 5. Viscous damping ratio, h%6 D i ffi i t B6. Damping coefficient, BL7. Isolator displacement, disol

    53

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol 17.953. Max. isolator force, Fm4. Effective period, Teff 5. Viscous damping ratio, h%6 D i ffi i t B6. Damping coefficient, BL7. Isolator displacement, disol

    54

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol 17.953. Max. isolator force, Fm 144.94. Effective period, Teff 5. Viscous damping ratio, h%6 D i ffi i t B6. Damping coefficient, BL7. Isolator displacement, disol

    55

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol 17.953. Max. isolator force, Fm 144.94. Effective period, Teff 1.465. Viscous damping ratio, h%6 D i ffi i t B6. Damping coefficient, BL7. Isolator displacement, disol

    56

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol 17.953. Max. isolator force, Fm 144.94. Effective period, Teff 1.465. Viscous damping ratio, h% 17.66 D i ffi i t B6. Damping coefficient, BL7. Isolator displacement, disol

    57

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol 17.953. Max. isolator force, Fm 144.94. Effective period, Teff 1.465. Viscous damping ratio, h% 17.66 D i ffi i t B 1 466. Damping coefficient, BL 1.467. Isolator displacement, disol

    58

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.00. Post-elastic stiffness, Kd 13.01. Isolator Displacement, disol 8.082. Effective stiffness, Kisol 17.953. Max. isolator force, Fm 144.94. Effective period, Teff 1.465. Viscous damping ratio, h% 17.66 D i ffi i t B 1 466. Damping coefficient, BL 1.467. Isolator displacement, disol 6.43

    59

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.0 40.00. Post-elastic stiffness, Kd 13.0 13.01. Isolator Displacement, disol 8.08 6.432. Effective stiffness, Kisol 17.953. Max. isolator force, Fm 144.94. Effective period, Teff 1.465. Viscous damping ratio, h% 17.66 D i ffi i t B 1 466. Damping coefficient, BL 1.467. Isolator displacement, disol 6.43

    60

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.0 40.0 40.00. Post-elastic stiffness, Kd 13.0 13.0 13.01. Isolator Displacement, disol 8.08 6.43 5.662. Effective stiffness, Kisol 17.95 20.063. Max. isolator force, Fm 144.9 113.64. Effective period, Teff 1.46 1.655. Viscous damping ratio, h% 17.6 22.46 D i ffi i t B 1 46 1 576. Damping coefficient, BL 1.46 1.577. Isolator displacement, disol 6.43 5.66

    61

  • Example 1 ContinuedStep Trial 1 Trial 2 Trial n0. Characteristic strength, Qd 40.0 40.0 40.00. Post-elastic stiffness, Kd 13.0 13.0 13.01. Isolator Displacement, disol 8.08 6.43 5.662. Effective stiffness, Kisol 17.95 20.063. Max. isolator force, Fm 144.9 113.64. Effective period, Teff 1.46 1.655. Viscous damping ratio, h% 17.6 22.46 D i ffi i t B 1 46 1 576. Damping coefficient, BL 1.46 1.577. Isolator displacement, disol 6.43 5.66

    62

  • Simplified MethodF

    Basic method assumes very

    Kd

    Qd

    F

    Kisol

    ystiff piers but method can

    dy disol

    F

    Superstructure Isolator Effective Stiffness, Kisol

    be modifiedto include dsub

    Ksub

    Substructure, Ksub

    Isolator(s), Kisol

    pier flexibility. sub

    Fdisol dsub

    Substructure Stiffness, Ksub

    Keff d

    63MCEER,2006.

    d = disol + dsub

    Combined Effective Stiffness, Keff

  • Multimodal Spectral Method Elastic Multimodal Method, developed for

    conventional bridges, may be used for isolated bridges even though they are nonlinear systems.

    Modeling the nonlinear properties of the isolators is usually done with equivalent linearized springs and the response spectrum is modified for theand the response spectrum is modified for the additional damping in the isolated modesin the isolated modes .Recall earlier discussionof the composite spectrum

    64

    p p

  • Multimodal Spectral Method

    Method is iterative and a good strategy is toMethod is iterative and a good strategy is to use the results from the Simplified Method of Analysis to obtain starting values for theAnalysis to obtain starting values for the iteration.

    In this case convergence in 1 or 2 cycles is ibl llpossible usually

    65

  • Isolator Design Analysis gives required system properties

    (Qd and Kd) to meet desired performance( d d) p Next step is to design an isolation system to

    have these propertieshave these properties Isolators used in bridge design include:

    Elastomeric bearings with lead cores (Lead Elastomeric bearings with lead cores (Lead-Rubber Bearing)

    Curved sliders (Friction Pendulum System) Curved sliders (Friction Pendulum System) Flat plate slider with elastomeric spring

    dampers (Eradiquake System)

    66

    dampers (Eradiquake System)

  • Elastomeric Isolator Design (LRB)

    67

  • Elastomeric Isolator Design (LRB) Qd = 0.9 d2 (K)

    where d = diameter of lead core (in)

    K = G A / T Kd = G Ar / Trwhere G = shear modulus of elastomer (e g 0 1 Ksi)G = shear modulus of elastomer (e.g. 0.1 Ksi)Ar = bonded area of elastomerT = total thickness of elastomerTr total thickness of elastomer

    Period (post-yield) =

    gT

    GgKWT rcd

    2)(2

    68

    Period (post yield) gGgKdd )(

  • Curved Sliding Isolators (FPS)

    R

    W

    Restoring force

    Friction

    g

    69

    D(Displacement)

  • Curved Sliding Isolator Design (FPS)POLISHED STAINLESS STEEL SURFACEPOLISHED STAINLESS STEEL SURFACE

    Qd = Wwhere SEALSEAL = coefficient of frictionW = weight per isolator

    STAINLESS STEELARTICULATED SLIDER(ROTATIONAL PART)

    COMPOSITE LINER MATERIAL

    SEAL

    RSTAINLESS STEELARTICULATED SLIDER(ROTATIONAL PART)

    COMPOSITE LINER MATERIAL

    SEAL

    R

    W weight per isolator

    K =

    ( )( )

    W Kd = whereR di f t f lid

    RW

    R=radius of curvature of slider

    R270

    Period when sliding = gRTd 2

  • Summary of LRB and FPS Designs

    El t i C d SlidElastomeric (LRB)

    Curved Slider(FPS)

    Number of isolators 12 12

    External dimensions9.4 in diam. 18 in diam.

    External dimensionsx 7.75 in height x 5 in (est.) height

    Internal dimensions 11 x in layers radius = 41 in

    Other 1.92 in diam. lead corecoefficient of

    friction = 0.075

    71

  • Eradiquake Isolator

    72

  • Other Design Issues (All) Restoring force capability Clearances (expansion joints, utility crossings )( p j y g ) Vertical load capacity and stability at high shear

    strain Uplift restrainers, tensile capacity Non-seismic requirements (wind, braking, thermal q ( g

    movements ) System Property Modification Factors (-factors) for

    aging, temperature, wear and tear, and contamination

    73

  • Topics

    Background Principles of Seismic Isolation, Some Applicationspp System Design Testing Requirements Testing Requirements

    74

  • Basic Testing Requirements Because isolators are subject to extreme

    deformations and loads during large g gearthquakes, most design codes require they be tested to demonstrate conformance with design expectations

    For both reasons (extreme loads andFor both reasons (extreme loads and extensive testing), design provisions for isolation bearings may differ from that forisolation bearings may differ from that for conventional bearings e.g., Section 14, AASHTO LRFD Design Specifications

    75

    AASHTO LRFD Design Specifications

  • Basic Testing RequirementsUsually three categories of tests are required:

    1. Characterization Tests to confirm basic C a acte at o ests o co bas cproperties such as effect of velocity, pressure, and temperature to develop models for analysis

    2. Prototype Tests for each project prior to production to confirm mechanical properties used in design

    3. Production Tests performed on each isolator ( l ith t i l t t ) f lit(along with material tests) for quality control/quality assurance.

    76

  • During this lecture we have learned: Basic purpose of seismic isolation Four components of an isolation systemFour components of an isolation system Bridge types / configurations suitable for

    seismic isolationseismic isolation How to calculate displacement and base

    shear in an isolated bridge using theshear in an isolated bridge using the Simplified Method

    About three kinds of isolators in use today

  • Five questions

    1. What is basic purpose of seismic isolation? 2 List the four components of an isolation system2. List the four components of an isolation system.3. Describe bridge types and configurations that

    are suitable for seismic isolation.are suitable for seismic isolation.4. Name three common types of isolators on the

    market today in the U.S. y5. Name three types of tests used to assure the

    quality of seismic isolatorsquality of seismic isolators