schindler planning guide moving one billion people · pdf fileschindler planning guide moving...

20
Schindler Elevators, Escalators and Moving Walks Schindler Planning Guide Moving one billion people every day all over the world

Upload: phamnhu

Post on 30-Jan-2018

247 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

Schindler Elevators, Escalators and Moving Walks

Schindler Planning GuideMoving one billion peopleevery day all over the world

Page 2: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

2 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler is leading the way with superior solutions for your building

Schindler designs, manufactures, installs, services and modernizes a broad range of elevators, escalators and moving walks for almost every building type. The company is the North American operation of the Schindler Group, headquartered in Switzerland, a leading global mobility provider, present in more than 100 countries. Schindler supports sustainable urban development with safe, reliable and ecologically sound mobility solutions.

Committed to environmental responsibilityDedicated to conducting its business activities in harmony with society and the environment, Schindler’s products and services are designed to provide energy efficient and eco-friendly options to architects, contractors, building owners and managers.

Schindler’s overall commitment to sustainability reflects a long-term investment in more than simply a clean, healthy environment — it also signifies smart business practices and a way of life.

Schindler has comprehensive targets for responsible economic, environmental and social performance.

Schindler achieved certification in 1996 to the internationally recognized environmental management system standard ISO 14001. The company is dedicated to continual improvement, compliance with legal and other requirements, pollution prevention, fostering of open communication, training of employees and working with its suppliers for mutually agreed solutions to limit environmental impact.

Schindler is also proud of its membership in the U.S. Green Building Council (USGBC). As a member, Schindler works to promote sustainable buildings that are environmentally responsible, profitable and healthy places to work and live.

In 2014 Schindler opened a new elevator manufacturing plant in Hanover, PA, becoming the first elevator factory in North America to

Page 3: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

3Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

achieve LEED® Gold Certification. Schindler’s Hanover facility implemented practical solutions and measurable strategies aimed at achieving high performance in sustainable site development, water conservation, energy efficiency, materials selection and indoor environmental quality. The Hanover facility serves as a model for future Schindler production facilities around the globe.

QualitySchindler was the first North American elevator company to achieve the internationally recognized quality standards of ISO 9001 certification over twenty years ago.

Customers benefit from our efforts toward total, integrated quality that permeates every area of the company: from service technicians to superintendents, sales representatives to office personnel, managers to plant employees.

LEED is a registered trademark of the U.S. Green Building Council.

Aesthetic appeal Schindler offers numerous choices when it comes to finishes and styles for your elevator cabs and fixtures, so that your equipment looks as good as it performs. Combining visual sophistication and advanced technology, our options for cabs and fixtures are built to suit any décor.

Service for all buildings, all brandsSchindler Service addresses your top priorities: reliable and safe performance, increasing equipment availability, avoiding major repairs, and retaining tenants no matter what brand of equipment you have.

Page 4: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

4 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

More than two decades ago, Schindler revolutionized the industry with its destination-dispatch elevator system which replaced pushbuttons in elevators with simple-to-use keypads. Passengers going to the same floor were grouped together to improve traffic handling and transport passengers to their destinations up to 40 percent faster and more efficiently than conventional systems.

Mobility made personalToday, the third generation destination-dispatch system, Schindler’s PORT Technology, offers personalized elevator service. Not only are travelers getting to their destinations faster and more efficiently, using electronic identification badges, PIN codes or other devices, passengers are recognized by the system and their trip is personalized and customized.

Schindler’s destination-dispatch technology has achieved enthusiastic acceptance by building owners and managers throughout the world. Its proven performance in offering a communications interface between the passenger and the elevator has set a new standard for efficient vertical transportation.

Schindler destination dispatch revolutionizes urban mobility

Page 5: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

5Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

A system for everyone and everyone is differentWith the PORT system, passengers’ only requirement is to simply communicate their identity and required destination. The PORT technology takes care of the rest by planning and executing a seamless journey using an optimal route designed to take the shortest possible time to complete. The intuitive system is ideal for use in new and existing buildings. With the ability to integrate seamlessly with any elevator system, regardless of original manufacturer, PORT technology sets a new standard for high performance buildings.

Elevator system upgrade. No downtime.A Destination Interface modernization may be the only step you need to take toward quickly improving a wide range of elevator performance requirements. Depending on the age and condition of your existing elevator system, Schindler may be able to connect to the existing control system, disconnect conventional dispatching and activate destination dispatching without the need to further modernize the elevator bank.

Compatible with most brands of equipment, Schindler’s Destination Interface can, with the “flip of a switch,” enable your current system to deliver all the features, functions and benefits of destination dispatching.

Page 6: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

6 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler 330A hydraulic elevator for low-rise buildings

High-efficiency designSchindler 330A holeless and borehole hydraulic elevator system available configurations:– Eco-friendly holeless design eliminates jack hole

and potential oil leakage in the ground– Single or dual-jack applications– Two to six stops– Speeds of up to 150 fpm– Front- and rear-opening doors– Side- or center-opening doors– Single- to multiple-car systems– Passenger or hospital/service use

– Capacities up to 5,000 lbs – Up to 35’-11” travel in standard hoistways; up

to 50’ with additional pit and/or overhead– Up to 60’/65’ travel; maximum rise can vary

with capacity and weight (borehole application only)

– Proven Schindler Miconic control system– Equipped with Schindler Remote Monitoring™.

Page 7: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

7Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Holeless Borehole

OH

TRAVEL

P

OH

TRA

VEL

PTR

AV

EL

+ 2’

-6”

C

CA

D CB

AB

C

CA

D CB

A

A

B

Capacity (lb) 4000** 4500** 5000**

Clear opening — A 4’-0” 4’-0” 4’-0”

Door system — B 2SSO 2SSO 2SSO

Minimum clear cab inside width — CA 5’-8” 5’-8” 5’-8”

Minimum clear cab inside depth — CB

Front opening 7’-3 1/2” 7’-9 1/2” 8’-5”

Front/rear opening 7’-4” 7’-10” 8’-5 1/2”

Hoistway width — C 7’-4” 7’-4” 7’-4”

Hoistway depth — D

Front opening 9’-0 1/2” 9’-6 1/2” 10’-2”

Front/rear opening 10’-2” 10’-8” 11’-3 1/2”

Minimum overhead dimension — OH

100 fpm 12’-0” 12’-0” 12’-0”

125 – 150 fpm 12’-3” 12’-3” 12’-3”

Minimum pit depth — P 4’-0” 4’-0” 4’-0”

C

MachineRoom

D+

6’-6

3’-6

” M

IN.

3’-0” MIN.

CA

CB

AB

C

DD

+ 6’-6”

3’-6”M

IN.

3’-0”MIN.

Machine

Machine RoomHatch PlansFront Opening

Front/Rear Opening

Capacity (lb) 2100 2500* 3000* 3500** 4000***

Clear opening — A 3’-0” 3’-6” 3’-6” 3’-6” 4’-0”

Door system — B SSSO SSSO SSCO

SSSO SSCO

SSSO SSCO

SSCO

Minimum clear cab inside width — CA

Single jack holeless 5’-8” 6’-8” – – –

Dual jack holeless and borehole 5’-8” 6’-8” 6’-8” 6’-8” 7’-8”

Minimum clear cab inside depth — CB

Single jack holeless 4’-3 1/2” 4’-3 1/2” – – –

Dual jack holeless and borehole, front opening 4’-3” 4’-3” 4’-9” 5’-5” 5’-5”

Dual jack holeless and borehole, front/rear opening 4’-3 1/2” 4’-3 1/2” 4’-9 1/2” 5’-5 1/2” 5’-5 1/2”

Hoistway width — C

Single jack holeless 7’-4” 8’-4” – – –

Dual jack holeless and borehole 7’-4” 8’-4” 8’-4” 8’-4” 9’-4”

Hoistway depth — D

Single jack holeless 6’-0” 6’-0” – – –

Dual jack holeless and borehole, front opening 5’-9” 5’-9” 6’-3” 6’-11” 6’-11”

Dual jack holeless and borehole, front/rear opening 6’-7 1/2” 6’-7 1/2” 7’-1 1/2” 7’-9 1/2” 7’-9 1/2”

Minimum overhead dimension — OH

100 fpm 12’-0” 12’-0” 12’-0” 12’-0” 12’-0”

125 – 150 fpm 12’-3” 12’-3” 12’-3” 12’-3” 12’-3”

Minimum pit depth — P 4’-0” 4’-0” 4’-0” 4’-0” 4’-0”

Schindler 330A General Purpose

Schindler 330A Hospital/Service

Notes:– Hoist beam to be removed by others after elevator installation if

minimum cab clearance is not available.– Maximum rail bracket vertical spacing is 14’-0”.– Adequate steel or concrete beam or concrete wall supports are required

for car guide rail mounting brackets based on elevator shop drawing loadings at each floor per ASME A17.1 Code. Mounting and interface between building support and car rail brackets to be in agreement between customer and elevator contractor.

– Holeless travel up to 41’-0” (single jack) or up to 50’-0” (dual jack) with additional pit and overhead.

– Holeless travel up to 33’-9” (single jack) or 35’-11” (dual jack) with standard pit and overhead.

– Overheads based on 8’-0” standard cab height.– Cab heights also available in 9’, 9’-6” and 10’ with additional overhead,

for dual jack holeless and borehole.– SSSO and 2SSO doors available with right or left opening.– For seismic applications, please contact your Schindler representative.

Keys:* Accommodates 76” x 24” stretcher with SSSO doors only.** Accommodates 76” x 24” stretcher with all size doors, or an 84” x 24”

stretcher with side opening doors.*** Accommodates up to an 76” x 24” stretcher with SSCO doors or

84” x 24” with a 5” corner radius.+ Machine room temperature to be maintained between 55°F and 90°F

(13°C and 32°C). Relative humidity to be maintained at 95% or less non-condensing. Please see specification for more detailed information.

Hoistways

Page 8: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

8 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

– Easy to order with accelerated lead and installation times

– Capacities up to 3500 lbs– Rises up to 98’-5” and a maximum of eight stops– Gearless/frequency controlled drive– Speeds up to 150 fpm– Interior finishes in powder coat, plastic laminate

or brushed stainless steel– Proven Schindler Miconic control system– Battery evacuation is standard.

Schindler 3300 MRL elevator for low- to mid-rise buildings

Spacious, smooth, sophisticated elevator designThe Schindler 3300 space-saving machine room-less elevator offers distinct design options, integrated green technology and smooth, quiet performance:– Spacious cab up to 5% larger than the average

MRL cab– Eco-friendly features lower operating costs– Smooth and quiet ride– Can fit into the footprint of a hydraulic elevator

Page 9: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

9Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Schindler 3300 General Purpose

Capacity Passengersmax.

Speed Number of stops

max.

Available entrances

max.

Car(Inside)

Door Shaft(Inside)

Travel height max.

lbs (kg)

fpm(m/s)

Ain

(mm)

Bin

(mm)

Cin

(mm)

Din

(mm)

Ein

(mm)

F (iii)(vii)

ft (mm)

Gft

(mm)

H (viii)

ft (mm)

I (iv)

ft (mm)

J (vi)

ft (m) / FPM (m/s)

2100 (950)

14100/150 (.5/.75)

8 8 Front5’-9 3/8” (1761)

4’-4 7/8” (1343)

7’-9” (2366)

2SSO3’-0” (915)

7’ (2134)

7‘-4“(vii) (2235)

5‘-9“ (1755)

5‘-0“ (1524)

12‘-7“ (3835)

59’ (17.7) / 100 (.5)

8/78 Front 7 Rear

7‘-4“(vii) (2235)

6’-5 5/8” (1972)

5‘-0“ (1524)

12‘-7“ (3835)

98’-5” (30.0) / 150 (.75)

2500 (1135)

17100/150 (.5/.75)

8 8 Front6’-9 3/8” (2066)

4’-4 7/8” (1343)

7’-9” (2366)

2SSO/SSCO

3’-6” (1067)

7’ (2134)

8‘-4“(vii) (2540)

5‘-9“ (1755)

5‘-0“ (1524)

12‘-7“ (3835)

59’ (17.7) / 100 (.5)

8/78 Front 7 Rear

8‘-4“(vii) (2540)

6’-5 5/8” (1972)

5‘-0“ (1524)

12‘-7“ (3835)

98’-5” (30.0) / 150 (.75)

3000 (1360)

20100/150 (.5/.75)

8 8 Front6’-9 3/8” (2066)

4’-10 7/8” (1495)

7’-9” (2366)

2SSO/SSCO

3’-6” (1067)

7’ (2134)

8‘-4“(vii) (2540)

6‘-3“ (1905)

5‘-0“ (1524)

12‘-7“ (3835)

59’ (17.7) / 100 (.5)

8/78 Front 7 Rear

8‘-4“(vii) (2540)

6’-11 5/8” (2124)

5‘-0“ (1524)

12‘-7“ (3835)

98’-5” (30.0) / 150 (.75)

3500 (1590)

23100/150 (.5/.75)

8 8 Front6’-9 3/8” (2066)

5’-6 7/8” (1699)

7’-9” (2366)

2SSO/SSCO

3’-6” (1067)

7’ (2134)

8‘-4“(vii) (2540)

6‘-11“ (2110)

5‘-0“ (1524)

12‘-7“ (3835)

59’ (17.7) / 100 (.5)

8/78 Front 7 Rear

8‘-4“(vii) (2540)

7’-7 5/8” (2328)

5‘-0“ (1524)

12‘-7“ (3835)

82’-0” (25.0) / 150 (.75)

A Inside cab widthB Inside cab depthC Inside cab height to underside of roof is above. Inside cab height to finished ceiling is 7’-5 3/16” (2265).

2SSO 2-speed side opening (i)SSCO Single speed center

opening

D Door WidthE Door Height

F Shaft widthG Shaft depthH Pit depthI Overhead

F

A

D

GB

F

A

D

GB

A

F

D

B G

F

A

D

GB

A

F

D

B G

F

A

D

GB

Front openingtwo-speed left opening

(2SSO)

Front openingtwo-speed right opening

(2SSO)

Front openingsingle-speed center

opening (SSCO)

(ix) Front/rear opening (ix)

two-speed left opening (2SSO)

(ix) Front/rear opening (ix)

two-speed right opening (2SSO)

Front/rear openingsingle-speed center

opening (SSCO)

E

E

C I

J

H

E

EE

C I

J

H

HoistwaysFront Opening Front/Rear Opening

Notes:(i) 2SSO doors available with right or left opening.(ii) Duplex operation available. (iii) For areas in seismic zone 2 or greater, provide additional

2” (50 mm) on the F dimension.(iv) Clear overhead is defined as the lowest point below any

obstruction such as: hoist beam(s), building beams, or roof structure.

(v) Where permitted by code, no control closet is required. A 3-phase and 110v disconnect must be located in both the hoistway overhead and a location in the building outside of the hoistway. The latter is not required to be an elevator-dedicated space.

(vi) Travel height max. varies depending on speed (FPM) and capacity (lbs).

(vii) Schindler recommends 8’-6” (2500 – 3500 lbs) and 7’-6” (2100 lbs), providing additional hoistway tolerances.

(viii) Please contact your Schindler Sales Representative for options less than 5’-0.

(ix) Please contact your Schindler Sales Representative for additional hatch options such as diagonal entrances.

Keys:– 2500 lb and 3000 lb will accommodate a 24” x 76”

stretcher with 2SSO doors only.– 3500 lb will accommodate a 24” x 76” stretcher with either

2SSO or SSCO doors.– 3000 lb will accommodate a 24” x 84” stretcher with 2SSO

doors per IBC 2009 Code. For IBC 2006 code, a 3500 lb cab will be required.

– 3500 lb will accommodate a 24” x 84” stretcher with 2SSO doors only.

– IBC 2009 code accommodates a stretcher radius of 5”. The IBC 2006 code is silent on the radius, therefore a 2” radius is estimated as worse case.

– For front/rear applications, the openings MUST be staggered (diagonal facing) openings in order to allow stretcher entering one side and exiting on another side.

Doortype

Page 10: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

10 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler 400AE traction elevator for mid-rise buildings

Dynamic. Durable. Distinguished. Schindler 400AE energy-saving, traction elevator system available configurations:– Space-saving, machine room-less design– Also available in machine room above

applications– General purpose capacities up to 4,000 lbs– Hospital/service capacities up to 5,000 lbs and

5,000 AIA lbs– Speeds up to 500 fpm– Rises up to 260 ft– Cab height up to 10 ft– One- to six-car systems

– Energy efficient permanent magnet gearless machines

– Power Factor 1 regenerative drives are available as an option

– Proven Schindler Miconic control system– Equipped with Schindler Remote Monitoring™

– The PORT Technology destination-dispatch system is available

– Remote distance capability between hoistway and control space/room

– Counterweight safety available when occupied space below hoistway

– Battery evacuation available as an option.

Page 11: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

11Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Schindler 400AE General Purpose Front Opening (Rear Counterweight)

Capacitylb (kg)

Clear Opening

Widthft (mm)

OpeningType

(i)

Platform SizeMinimum Clear Cab

InsideHoistway (iv, v) Pit Depth (P) (v) Overhead (OH) (iii) (vi)

A Width

ft (mm)

B Depth

ft (mm)

CA Width

ft (mm)

CB Depth

ft (mm)

C Clear Width

ft (mm)

D Wall to Wall

ft (mm)

200 fpm 1.0 m/s

350 fpm 1.75 m/s

500 fpm2.5 m/s

200 fpm 1.0 m/s

350 fpm 1.75 m/s

500 fpm2.5 m/s

2500 (1136)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

5’-1” (1549)

6’-8” (2032)

4’-3” (1295)

8’-4” (2540)

6’-7 1/2” (2019)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

14’-8” (4470)

15’-2” (4623)

16’-8” (5080)

3000 (1364)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

5’-7” (1702)

6’-8” (2032)

4’-9” (1448)

8’-4” (2540)

7’-1 1/2” (2172)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

14’-8” (4470)

15’-2” (4623)

16’-8” (5080)

3500 (1591)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

6’-3” (1905)

6’-8” (2032)

5’-5” (1651)

8’-4” (2540)

7’-9 1/2” (2375)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

14’-8” (4470)

15’-2” (4623)

16’-8” (5080)

4000 (1818)

4’-0” (1219)

SSCO8’-1”

(2464)6’-3”

(1905)7’-8”

(2337)5’-5”

(1651)9’-4”

(2845)7’-9 1/2” (2375)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-8” (4775)

16’-2” (4928)

N/AN/A

Schindler 400AE General Purpose Front Opening (Side Counterweight)

2100 (955)

3’-0” (914)

SSSO6’-1”

(1854)5’-1”

(1549)5’-8”

(1727)4’-3”

(1295)8’-0”

(2438)5’-9”

(1753)5’-4”

(1626)5’-7”

(1702)6’-8”

(2032)13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

2500 (1136)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

5’-1” (1549)

6’-8” (2032)

4’-3” (1295)

9’-0” (2743)

5’-9” (1753)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

3000 (1364)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

5’-7” (1702)

6’-8” (2032)

4’-9” (1448)

9’-0” (2743)

6’-3” (1905)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

3500 (1591)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

6’-3” (1905)

6’-8” (2032)

5’-5” (1651)

9’-0” (2743)

6’-11” (2108)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

4000 (1818)

4’-0” (1219)

SSCO8’-1”

(2464)6’-3”

(1905)7’-8”

(2337)5’-5”

(1651)10’-2” (3099)

7’-3” (2210)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-2” (4623)

15’-8” (4775)

N/AN/A

Schindler 400AE General Purpose Front and Rear Opening (Side Counterweight)

2500 (1136)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

5’-7” (1702)

6’-8” (2032)

4’-3 1/2” (1308)

9’-0” (2743)

6’-7 1/2” (2019)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

3000 (1364)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

6’-1” (1854)

6’-8” (2032)

4’-9 1/2” (1461)

9’-0” (2743)

7’-1 1/2” (2172)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

3500 (1591)

3’-6” (1067)

SSSO SSCO

7’-1” (2159)

6’-9” (2057)

6’-8” (2032)

5’-5 1/2” (1664)

9’-0” (2743)

7’-9 1/2” (2375)

5’-4” (1626)

5’-7” (1702)

6’-8”(2032)

13’-9” (4191)

14’-3” (4343)

15’-9” (4801)

4000 (1818)

4’-0” (1219)

SSCO8’-1”

(2464)6’-9”

(2057)7’-8”

(2337)5’-5 1/2” (1664)

10’-2” (3099)

7’-9 1/2” (2375)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-2” (4623)

15’-8” (4775)

N/AN/A

Notes(i) SSSO and 2SSO doors available with right or left opening. 2SSO doors available in 4’-6” (1372 mm) width for all Hospital/Service Side Counterweight with addition of 2” (51 mm)

hoistway width. (ii) Up to 6 car bank available. Flexible control space/room placement available up to 250’ (76 m) from the machine. Consult your local sales representative.(iii) OH dimensions based on 8’ (2438 mm) cab. Clear overhead is defined as the lowest point below any obstruction such as: hoistbeam(s), building beams, or roof structure.

9’, 9’-6” and 10’ (2743 mm, 2896 mm, 3048 mm) cab options available with increased overhead. When the control space/room is remotely located, an additional 6” (152 mm) of overhead is required.

(iv) For areas in seismic zone 2 or greater, provide additional hoistway size as follows: Increase width C by: 4” (102 mm) for General Purpose Rear Counterweight and General Purpose Side Counterweight; 2” (51 mm) for 4000 lb General Purpose Side and

Rear Counterweight and all Hospital/Service Side Counterweight. Increase depth D by: 2” (51 mm) for General Purpose Side Counterweight, 2100 lb, 2500 lb, and 3000 lb capacities with Front Opening only.(v) When there is occupied space below the hoistway, additional hoistway size and extra pit depth are required as follows: – For General Purpose Side Counterweight add 4” (102 mm) to width C on machine side for non-seismic (all capacities), 2” (51 mm) to width C on machine side for seismic

(2100 – 3500lb) or 3” (76 mm) to width C on machine side for seismic (4000lb), and 12” (305 mm) to pit depth P (8’ cab only) (all capacities). – For General Purpose Rear Counterweight add 4” (102 mm) to depth D and 12” (305 mm) to pit depth P (8’ cab only). – For Hospital Service Side Counterweight add 12” (305 mm) to pit depth P (8’ cab only).(vi) 2500 lb – 4000 lb capacity General Purpose Rear Counterweight requires additional overhead or machine room coordination. Please contact your local Schindler sales representative.

Page 12: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

12 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler 400AE streamlined MRL designwith dynamic space and time savings

Hatch PlanMachine Room Less

Hatch PlanMachine Room Above

C

CA

CB

A

DB

General Purpose Front Opening General Purpose Front Opening

Front Opening Front Opening

General Purpose Front and Rear Opening

General Purpose Front and Rear Opening

OH

8‘ (2

438

mm

)TR

AV

ELP

7‘ (2

134

mm

)

CA

DBCB

CA

C

CA

CB

A

DB

OH

TRAVEL

P

CA

D

1’-8

” x

6’-0

”ty

pica

l + CB

CA

HoistwayMachine Room Less

HoistwayMachine Room Above

Page 13: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

13Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Hatch PlanMachine Room Above

Front Opening

Schindler 400AE Hospital/Service Front Opening (Side Counterweight)

Capacitylb (kg)

Clear Opening

Widthft (mm)

OpeningType

(i)

Platform SizeMinimum Clear Cab

InsideHoistway (iv, v) Pit Depth (P) (v) Overhead (OH) (iii)

A Width

ft (mm)

B Depth

ft (mm)

CA Width

ft (mm)

CB Depth

ft (mm)

C Clear Width

ft (mm)

D Wall to Wall

ft (mm)

200 fpm 1.0 m/s

350 fpm 1.75 m/s

500 fpm2.5 m/s

200 fpm 1.0 m/s

350 fpm 1.75 m/s

500 fpm2.5 m/s

4000 (1818)

4’-0” (1219)

2SSO6’-1”

(1854)8’-3”

(2515)5’-8”

(1727)7’-3 1/2” (2222)

8’-2” (2489)

9’-1 1/2” (2781)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-2” (4623)

15’-8” (4775)

N/AN/A

4500 (2045)

4’-0” (1219)

2SSO6’-1”

(1854)8’-9”

(2667)5’-8”

(1727)7’-9 1/2” (2375)

8’-2” (2489)

9’-7 1/2” (2934)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-2” (4623)

15’-8” (4775)

N/AN/A

5000(2272)

4’-0”(1219)

2SSO6’-1”

(1854)9’-4 1/2”(2858)

5’-8”(1727)

8’-5”(2565)

8’-2”(2489)

10’-3”(3124)

5’-8”(1727)

6’-1”(1854)

N/AN/A

16’-5”(5004)

16’-11”(5156)

N/AN/A

5000 AIA(2272)

4’-0”(1219)

2SSO6’-1”

(1854)9’-11 1/2”(3035)

5’-8”(1727)

9’-0”(2743)

8’-2”(2489)

10’-10”(3302)

5’-8”(1727)

6’-1”(1854)

N/AN/A

16’-5”(5004)

16’-11”(5156)

N/AN/A

Schindler 400AE Hospital/Service Front and Rear Opening (Side Counterweight)

4000 (1818)

4’- 0” (1219)

2SSO6’-1”

(1854)8’-10 1/2”

(2705)5’-8”

(1727)7’-4”

(2235)8’-2”

(2489)10’-2” (3099)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-2” (4623)

15’-8” (4775)

N/AN/A

4500 (2045)

4’- 0” (1219)

2SSO6’-1”

(1854)9’-4 1/2” (2858)

5’-8” (1727)

7’-10” (2388)

8’-2” (2489)

10’-8” (3251)

5’-8”(1727)

6’-1”(1854)

N/AN/A

15’-2” (4623)

15’-8” (4775)

N/AN/A

5000(2272)

4’-0”(1219)

2SSO6’-1”

(1854)10’-0”(3048)

5’-8”(1727)

8’-5 1/2”(2578)

8’-2”(2489)

11’-3 1/2”(3124)

5’-8”(1727)

6’-1”(1854)

N/AN/A

16’-5”(5004)

16’-11”(5156)

N/AN/A

5000 AIA(2272)

4’-0”(1219)

2SSO6’-1”

(1854)10’-7”(3226)

5’-8”(1727)

9’-0 1/2”(2756)

8’-2”(2489)

11’-10 1/2”(3620)

5’-8”(1727)

6’-1”(1854)

N/AN/A

16’-5”(5004)

16’-11”(5156)

N/AN/A

Notes(i) SSSO and 2SSO doors available with right or left opening. 2SSO doors available in 4’-6” (1372 mm) width for all Hospital/Service Side Counterweight with addition of 2” (51 mm)

hoistway width. (ii) Up to 6 car bank available. Flexible control space/room placement available up to 250’ (76 m) from the machine. Consult your local sales representative.(iii) OH dimensions based on 8’ (2438 mm) cab. Clear overhead is defined as the lowest point below any obstruction such as: hoistbeam(s), building beams, or roof structure.

9’, 9’-6” and 10’ (2743 mm, 2896 mm, 3048 mm) cab options available with increased overhead. When the control space/room is remotely located, an additional 6” (152 mm) of overhead is required.

(iv) For areas in seismic zone 2 or greater, provide additional hoistway size as follows: Increase width C by: 4” (102 mm) for General Purpose Rear Counterweight and General Purpose Side Counterweight; 2” (51 mm) for 4000 lb General Purpose Side and

Rear Counterweight and all Hospital/Service Side Counterweight. Increase depth D by: 2” (51 mm) for General Purpose Side Counterweight, 2100 lb, 2500 lb, and 3000 lb capacities with Front Opening only.(v) When there is occupied space below the hoistway, additional hoistway size and extra pit depth are required as follows: – For General Purpose Side Counterweight add 4” (102 mm) to width C on machine side for non-seismic (all capacities), 2” (51 mm) to width C on machine side for seismic

(2100 – 3500lb) or 3” (76 mm) to width C on machine side for seismic (4000lb), and 12” (305 mm) to pit depth P (8’ cab only) (all capacities). – For General Purpose Rear Counterweight add 4” (102 mm) to depth D and 12” (305 mm) to pit depth P (8’ cab only). – For Hospital Service Side Counterweight add 12” (305 mm) to pit depth P (8’ cab only).(vi) 2500 lb – 4000 lb capacity General Purpose Rear Counterweight requires additional overhead or machine room coordination. Please contact your local Schindler sales representative.

Page 14: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

14 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler 7000™ traction elevator for high-rise buildings

Our top range, high performance elevator system can be found in many of the world’s landmark buildings thanks to its premium ride quality, top performance, excellent reliability and innovative design. The Schindler 7000™ offers unsurpassed performance and customized options for the most discerning customers.

Schindler 7000 offers various solutions tailored to suit a creative architectural design*– Code and design criteria — complying with the

applicable code and design data (seismic and non-seismic)

– Custom and flexible design to fit office, residential or institutional buildings

– Product reliability, smooth ride and long term partnership

– High ride quality performance at highest speeds– Ride quality measures: structural and

aerodynamic car and high comfort measures*– Building sway management solution for high

rise buildings*– Double deck solutions can increase rentable

space– Proven Schindler Miconic control system– Fully complies with ISO 18738 requirements– The PORT Technology destination-dispatch

system is available– Power Factor 1 drives reduce energy

consumption and regenerates energy back into the buildings electrical system.

Page 15: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

15Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Schindler 7000 General Elevator Data*Building type Office, residential, institutional

Rated speed 500 fpm – 2000 fpm*

Rated load 2500 lbs – 8800 lbs*

Travel height <=1640 ft **

Elevator type Single-deck, double-deck***

Elevator use Passenger, service

Number of cars 1 – 8

Control type Conventional and destination

Notes:* Consult local Schindler representative for details.** Travel height varies depending on speed and elevator type.*** Depending on speed, travel height and zoning.

Schindler 7000 Double-deck elevators

Schindler 7000 Single-deck

Schindler 7000 General LEED Data*Item Application Benefits

Energy – When utilized gearless high efficient with power factor PF1 technology and regenerative drive, energy efficiency is up to 35% in comparison to the standard drive*

– Unique destination control technology together with gearless high efficient PF1 provides numerous planning solutions for busy high rise office buildings with the most energy efficient possible way, intelligently communicating with the building occupants*

– Destination control ergonomically friendly design produces very efficient use of the elevator bank during peak hours.*

– Generating less heat reduces the energy needed to maintain machine room temperature*– Saved energy returned back in the building main line to use for other energy savings, possibly lowering

building’s overall energy consumption*– Providing vertical communication optimizing effectively number of elevator trips (starts and stops) that will

preserve energy– Assisting architects to effectively plan buildings with different occupants providing the highest possible

level of service.

LEED – Corporate commitment and green orientation* – Per project basis, cab panels constructed from environmentally friendly materials

containing no added urea-formaldehyde*– Schindler continuously supports research and development effort focused on bringing

“greener” mobility innovations to the worldwide market.

– LEED AP to assist per project basis– Possibilities to help the project earn credits and meet project environmental plans*– Schindler’s U.S. manufacturing facilities in Gettysburg and Clinton are ISO 14001 certified.

Notes:*Consult local Schindler representative for details.

Page 16: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

16 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler 9300AE is the versatile escalator

Stylish and at home in any environmentWith configuration packages and rises up to 42 feet, the Schindler 9300AE escalator system has design features that include:– Two, three and four flat step configurations

to meet special building design and traffic requirements

– Elegant, rounded balustrade, and innovative, stylish handrail entry for timeless appeal

– Unprecedented choice of colors for handrails, steps, skirt panels, decking, endcaps and more

– Advanced gear technology, setting new levels of quietness and smoothness of operation

– Three step widths for optimal passenger flow and space requirements

– Exceptionally tough 1/2” stainless steel sandwich panels providing inclined balustrades with outstanding durability

– Mechanical components designed to meet the extreme demands of public transit operations, regardless of environmental conditions

– Weatherproofing options allow outdoor operation in virtually any climate

– Over two dozen important safety features– Schindler’s optional ECOLINE* packages deliver

significant energy savings.

Color options expands your possibilities With the Schindler 9300AE, you have unprecedented choice in colors. Expand your possibilities with scratch-resistant powder-coated colored steps, colored handrails, escalator skirt panels and decking in an unlimited selection of antifriction, scratch-resistant colors, or newel end caps in an unlimited color selection.

* Where applicable by code.

Page 17: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

17Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Model 9300AE-10 two flat steps 60 80 100

Nominal escalator width 32” 40” 48”

Nominal step width 24” 32” 40”

Step width A 1’-11 5/8” 2’-7 1/2” 3’-3 3/8”

Inside to inside handrail — B 2’-5 13/16” 3’-111/16” 3’-9 9/16”

Centerline to centerline handrail — C 2’-9” 3’-4 7/8” 4’-0 3/4”

Outer deck to outer deck — D 3’-8 7/8” 4’-4 3/4” 5’-0 5/8”

Wellway opening single unit — E 3’-111/4” 4’-7 1/8” 5’-3”

Wellway opening two adjacent units — E 7’-8 1/2” 9’-0 1/4” 10’-4”

Pit length — F (+ 3/4”–0” ) 14’-6” 14’-6” 14’-6”

Maximum rise — H ( ± 1/4” ) * 39’-4” 30’-6” 26’-3”

Edge to edge of supports — L (± 1/4” ) H x 1.732 + 15’-6 1/2”

Model 9300AE-20 three flat steps 60 80 100

Nominal escalator width 32” 40” 48”

Nominal step width 24” 32” 40”

Step width — A 1’-11 5/8” 2’-7 1/2” 3’-3 3/8”

Inside to inside handrail — B 2’-5 13/16” 3’-111/16” 3’-9 9/16”

Centerline to centerline handrail — C 2’-9” 3’-4 7/8” 4’-0 3/4”

Outer deck to outer deck — D 3’-8 7/8” 4’-4 3/4” 5’-0 5/8”

Wellway opening single unit — E 3’-11 1/4” 4’-7 1/8” 5’-3”

Wellway opening two adjacent units — E 7’-8 1/2” 9’-0 1/4” 10’-4”

Pit length — F (± 3/4”) 15’-9” 15’-9” 15’-9”

Maximum rise — H (± 1/4”) * 55’-9” 49’-2 1/2” 42’-7 3/4”

Maximum edge to edge of supports — L (± 1/4”) H x 1.732 + 18’-6 3/4”

L1’- 5 5/8”

30°

4’-0

F

± 1 /4

± 1/4”

± 3/4”

H

CBA

DE

Notes:– Dimensions are for applications in the United States. Some dimensions change for seismic applications.

For specific requirements in Canada, please consult your local sales office. Schindler Elevator Corporation reserves the right to change dimensions.

Keys:* Higher rises may be available; please contact your local sales representative.

Schindler 9300AE Elevation

Schindler 9300AE

Page 18: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

18 Schindler Elevators, Escalators and Moving Walks Visit www.us.schindler.com for the latest information and drawings

Schindler 9500® moving walkfor inclined and horizontal transportation

Found in the world’s busiest airports, exhibition halls, subway systems and shopping complexesWith their minimum pit space requirements, Schindler 9500® moving walks are available in various combinations for multiple applications with design features including:– Shallow mid-sections make installation on finished floors possible– Ribbed aluminum floor covers are sound proofed and feature a black

anodized base– Glass balustrades enhance styling– Opaque panels are available in a variety of finishes– Digital diagnostic panel displays moving walk functions and safety device

status to expedite trouble shooting and minimize downtime– All renowned Schindler safety features are included, as well as a unique

pallet and skirt arrangement which eliminates horizontal skirt gap– Schindler’s optional ECOLINE* packages deliver significant energy savings.

* Where applicable by code.

4’-0

F±3/4”–0”

10°, 11°, 12°

L ± 1/4”

± 1 /4

”H

Reversing station

3’-9

1/4

3’-9

1/4

”3’

-3 3

/8”

3’-3

3/8

3’-3

3/8

4’-7 9/16”

16’-6 13/16” 16’-6 13/16”

4’-7 9/16”L

Drive station

Reversing station Drive station

17’-8 5/8”

2’-7 11/16”

2’-1 3/8” R5=every 3’-11 1/4”x 3’-11 1/4”

2’-1”3’-9

1 /4”

3’-9

1 /4”17’-8 5/8”

2’-7 11/16”

±1 3/16”

L ±1 3/16”

Schindler 9500AE-15 Schindler 9500-30

Schindler 9500-45

Model 9500AE-15 inclined (10°, 11°, 12°) 80 100

Nominal walk width 40” 48”

Nominal pallet width 32” 40”

Pallet width — A 2’-71/2” 3’-3 3/8”

Inside to inside handrail — B 3’-111/16” 3’-9 9/16”

Centerline to centerline handrail — C 3’-4 7/8” 4’-0 3/4”

Outer deck to outer deck — D 4’-4 3/4” 5’-0 5/8”

Wellway opening single unit — E 4’-7 1/8” 5’-3”

Wellway opening two adjacent units — E 9’-0 1/4” 10’-4”

10° pit length — F (+3/4” – 0”) 21’-0” 21’-0”

11° pit length — F (+3/4” – 0”) 19’-4 1/4” 19’-4 1/4”

12° pit length — F (+3/4” – 0”) 18’-0 1/2” 18’-0 1/2”

Maximum rise — H 30’-6” 24’-7”

10° edge to edge of supports — L (±1/4”)* (H + 0.1795’) x 5.6713 + 16’-2 5/16”

11° edge to edge of supports — L (±1/4”)* H x 5.1446 + 16’-2 5/16”

12° edge to edge of supports — L (±1/4”)* (H – 0.1795’) x 4.7046 + 16’-2 5/16”

Maximum edge to edge of supports — L (±1/4”)* 53’-5 3/4” 49’-2 1/2”

Models 9500-30 9500-45

Maximum length at an inclination of 0° 328’ 492’

Balustrade Design E Design P

Balustrade height 3’-3 3/8” 3’-3 3/8”

Truss Full truss along entire length In drive & reversing station only

Inclination 0° – 3° 0° – 3°

Pallet width 40”/48”/56” 40”/48”/56”

Notes:– In case of outdoor installations, a water drain should be provided. – Dimensions are for applications in the United States. Some dimensions change for

seismic applications. For specific requirements in Canada, please consult your local sales office. Schindler Elevator Corporation reserves the right to change dimensions.

– Please contact your local Schindler sales representative for more information on the 9500-30 and 9500-40.

Keys:* If L > max, intermediate support is required. Please contact your local Schindler sales

office for reaction and location.

Schindler 9500 Advanced Edition Schindler 9500

Page 19: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

19Visit www.us.schindler.com for the latest information and drawings Schindler Elevators, Escalators and Moving Walks

Schindler 9700Size 1 and 2 Size 3

Model 9700-20 two flat steps 80 100 80 100

Upper transition radius 4’-11 1/16” 4’-11 1/16” 4’-11 1/16” 4’-11 1/16”

Lower transition radius 3’-3 3/8” 3’-3 3/8” 3’-3 3/8” 3’-3 3/8”

Step width — A 2’-7 1/2” 3’-3 3/8” 2’-7 1/2” 3’-3 3/8”

Inside to inside handrail — B 3’-6 5/8” 4’-2 1/2” 3’-6 5/8” 4’-2 1/2”

Centerline to centerline handrail — C 3’-9 3/4” 4’-5 5/8” 3’-9 3/4” 4’-5 5/8”

Outer deck to outer deck — D 4’-10 11/16” 5’-6 1/2” 5’-2 9/16” 5’-10 1/2”

Wellway opening single unit — E 5’-1” 5’-8 7/8” 5’-4 1/2” 6’-0 13/16”

Wellway opening two adjacent units — E 9’-11 11/16” 11’-3 7/16” 10’-7 3/4” 11’-11 3/16”

Pit length — F (+ 3/4” – 0”) 15’-1 1/8” 15’-1 1/8” 15’-1 1/8” 15’-1 1/8”

Edge to edge supports — L (+/- 1/4”) H x 1.732 + 16’-2 7/16”

Schindler 9700® escalatorfor high requirement and high rises

L

30°

F

± 1 /4

± 1/4”

± 3/4”

H

CBADE

Notes:– Nominal rise according to A17.1 with A = 1000 mm.– Size 1: max. 16 m, Size 2: max. 22 m, Size 3: max. 30 m.– Dimensions are for single drive configurations. – Please contact Schindler for dimensions relating to truss extensions, double drives,

drive units in cages, PLC controls and rises above 16 m.

Schindler 9700

Stylish and at home in any environmentThe Schindler 9700® escalator system has design features that include:– Two, three and four flat step configurations to meet special building design

and traffic requirements– Unprecedented choice of colors for handrails, steps, skirt panels, decking,

and more– Advanced gear technology, setting new levels of quietness and smooth-

ness of operation– Two step widths for optimal passenger flow and space requirements– Exceptionally tough 1/2” stainless steel sandwich panels providing inclined

balustrades with outstanding durability– Mechanical components designed to meet the extreme demands of

public transit operations, regardless of environmental conditions– Weatherproofing options allow outdoor operation in virtually any climate– Over two dozen important safety features– Schindler’s optional ECOLINE* packages deliver significant energy savings.

* Where applicable by code.

Size 1 and 2 Size 3Model 9700-30 three flat steps 80 100 80 100

Upper transition radius 8’-10 5/16” 8’-10 5/16” 8’-10 5/16” 8’-10 5/16”

Lower transition radius 6’-6 3/4” 6’-6 3/4” 6’-6 3/4” 6’-6 3/4”

Step width — A 2’-7 1/2” 3’-3 3/8” 2’-7 1/2” 3’-3 3/8”

Inside to inside handrail — B 3’-6 5/8” 4’-2 1/2” 3’-6 5/8” 4’-2 1/2”

Centerline to centerline handrail — C 3’-9 3/4” 4’-5 5/8” 3’-9 3/4” 4’-5 5/8”

Outer deck to outer deck — D 4’-10 11/16” 5’-6 1/2” 5’-2 9/16” 5’-10 1/2”

Wellway opening single unit — E 5’-1” 5’-8 7/8” 5’-4 1/2” 6’-0 13/16”

Wellway opening two adjacent units — E 9’-11 11/16” 11’-3 7/16” 10’-7 3/4” 11’-11 3/16”

Pit length — F (+ 3/4” – 0”) 17’-2 11/16” 17’-2 11/16” 17’-2 11/16” 17’-2 11/16”

Edge to edge supports — L (+/- 1/4”) H x 1.732 + 20’-9 1/8”

Notes:– Dimensions are for applications in the United States. Some dimensions change

for seismic applications. For specific requirements in Canada, please consult your local sales office. Schindler Elevator Corporation reserves the right to change dimensions.

Keys:* Higher rises may be available; please contact your local sales representative.

Page 20: Schindler Planning Guide Moving one billion people · PDF fileSchindler Planning Guide Moving one billion people ... – Proven Schindler Miconic control system ... B C CA D CB A A

United StatesAlabamaBirmingham 205-252-5148Huntsville 205-252-5148

AlaskaAnchorage 907-276-3200

ArizonaTucson 520-628-1616Phoenix 480-557-9000

ArkansasLittle Rock 501-375-0930

CaliforniaFresno 559-240-0149Irvine 714-361-3043Los Angeles 818-336-3000Sacramento 916-928-9420San Diego 858-812-2330San Francisco 510-382-2075San Jose 510-382-2075

ColoradoDenver 303-777-5020

ConnecticutHartford/Stamford 860-257-1497

District of ColombiaWashington 301-419-7700

FloridaJacksonville 904-880-4922Miami 954-626-5555Naples 239-566-9795Orlando 407-235-1200Pensacola 850-473-1993Tallahassee 850-422-2258Tampa 813-888-5335

GeorgiaAtlanta 770-319-2900

HawaiiHonolulu 808-547-8500

IdahoBoise 208-577-5525

IllinoisChicago Downtown 312-730-7100Chicago Suburban 630-478-7179Springfield 217-527-1440

IndianaIndianapolis 317-486-0906Fort Wayne 260-484-3323Evansville 812-282-6900South Bend 574-243-0022

IowaDes Moines 515-243-6142

Kansas 816-474-9494

KentuckyLexington 812-282-6900Louisville 812-282-6900

LouisianaBaton Rouge 225-292-2137New Orleans 504-613-2300Lake Charles 409-838-3117Shreveport 318-635-8147

Maine 508-660-5454

Maryland Baltimore 410-401-2090

MassachusettsBoston 508-660-5454Springfield 413-205-2170

MichiganAnn Arbor 734-971-8242Detroit 734-367-9410Grand Rapids 616-656-1450Jackson 734-971-8242Kalamazoo 269-345-2219Lansing 517-272-1234Upper Michigan 989-790-2468

MinnesotaMinneapolis 651-406-5300

MississippiJackson 601-923-3344

MissouriColumbia 573-449-4312North Kansas City 816-474-9494St. Louis 314-372-4560

MontanaMissoula 406-822-5400

NebraskaOmaha 402-734-7572

NevadaLas Vegas 702-222-1875Reno 775-530-1508

New HampshireBoston, MA 508-660-5454

New JerseyNorth Jersey, Toll-Free 800-225-0140South Jersey 609-641-7880

New MexicoAlbuquerque 915-544-9260

New YorkAlbany 518-782-0744Buffalo 716-632-1463New York City 212-708-1000Long Island 516-860-1321Pougkeepsie 518-782-0744Rochester 585-352-2088Syracuse 315-472-4308Westchester 914-997-8300

North CarolinaCharlotte 704-329-1470Greensboro 336-992-0537Raleigh 919-954-9454

North DakotaFargo 701-235-2566

OhioAkron/Canton, Toll-Free 866-839-5430Cincinnati 513-341-2600Cleveland 216-391-8600Columbus 614-573-2777Dayton 937-254-5641Lima 419-223-9841Toledo 419-861-5900

OklahomaOklahoma City 918-627-1116Tulsa 918-627-1116

OregonPortland 503-286-9799

PennsylvaniaAllentown 610-391-8895Harrisburg 717-761-5273Philadelphia 856-234-2220Pittsburgh 412-578-6600

Puerto RicoSan Juan 787-641-8181

Rhode IslandProvidence 401-722-9161

South CarolinaCharleston 843-747-7350Greenville 864-627-5332

TennesseeMemphis 901-683-4581Nashville 615-242-4975

TexasAustin 512-451-3620Beaumont 409-838-3117Dallas 972-621-2500Fort Worth 817-335-5752Houston 713-692-7165San Antonio, Toll-Free 800-847-5876

UtahSaint George 435-673-4835Salt Lake City 801-487-0705

Vermont, Toll-Free 800-452-4117

VirginiaRichmond 804-727-3120Roanoke 540-992-1843Virginia Beach 757-464-0290

WashingtonPasco 509-545-6588Spokane 509-535-2471Seattle 206-291-3000

West VirginiaCharleston 412-578-6600Morgantown 412-578-6600

WisconsinMadison 608-237-5700Milwaukee 262-317-4170Oshkosh 920-730-8982

Wyoming 303-777-5020

CanadaAlbertaCalgary 403-243-0715Edmonton 780-425-1043

British ColombiaVancouver 604-253-2361

OntarioHamilton, Toll-Free 800-668-8171Ottawa 613-727-1289Toronto 416-332-8280

QuebecMontreal 514-737-7367

Schindler sales offices

SWN

-14

F142

.5

© S

chin

dler

Ele

vato

r C

orpo

ratio

n

For further information contact the Schindler office nearest you or visit:www.us.schindler.com

Schindler has received renewal to ISO 9001 and ISO 14001 certificates.

Schindler is a member organization of theU.S. Green Building Council.

Schindler prints with vegetable-based ink on paper containing post-consumer waste fiber.Follow us: