Paolucci INFN-Napoli Muon Annul Review Cern 15 September 2003 RPC cabling RPC cabling HV & LV cables Signal cables Position and composition of racks in UXC and USC

Upload: masao

Post on 22-Feb-2016

57 views

Category:

Documents


0 download

DESCRIPTION

HV & LV cables Signal cables Position and composition of racks in UXC and USC. RPC cabling. HV cable layout (from UXC55 vs USC55). Required characteristic CERN safety instruction IS23: Flame retardant (IEC 60332-3 Cat. C) Zero halogene (IEC 60754-1) Smoke density (IEC 61034) - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

RPC cabling

• HV & LV cables• Signal cables

• Position and composition of racks in UXC and USC

Page 2: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

HV cable layout (from UXC55 vs USC55)

Conductor @ 15 KV(DC)with individual insulating sheath

Braided shield

Signal return

Required characteristicCERN safety instruction IS23:•Flame retardant (IEC 60332-3 Cat. C)•Zero halogene (IEC 60754-1)•Smoke density (IEC 61034)•Corrosiveness of combustion gases (IEC 60754-1)•Maximum current per conductor: 500 uA•Maximum voltage per conductor: 15 KV-DC

External sheath

Internal sheath

Page 3: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

HV cables characteristics

• Multiconductor cable 8 x (3x0.22) H2M1 Halogene Free 15 kV cc (from patch panels towards tower to patch panel on USC)– External diameter 26.2 mm (nominal)– Weight (indicative) 826 g/m

• Cable 1 x (3x0.22) H2M1 Halogene Free 15 kV cc (from detector towards patch panels on towers)– External diameter 7.7 mm (nominal)– Weight (indicative) 82 g/m

• Manufacturer: NOVACAVI

Page 4: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

LV cable characteristics

• Cable 12 x 0.75 (RB2/3 case):– Braided shield: copper– External diameter (nominal): 10.1 mm– Weight (indicative): 175 g/m

• Cable 8 x 0.75 (RB2/2 case):– Braided shield: copper– External diameter (nominal): 9.0 mm– Weight (indicative): 156 g/m

• Manufacturer: NOVACAVI

Page 5: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Signal cable characteristics

• 20 twisted pairs cable• Very low skew cable (1-2 ns between pairs for 25 m max length)• Conductor cross section: 28 AWG• Insulator: PE• Global shield: tinned copper braid• External shield: PE• Total external diameter: 12-13 mm• Rated voltage: 10 V (used for LVDS signal transmission)• Operating temperature: 0°/+60°C• Characteristic impedance: 110 (10%)• CERN safety instruction IS23 compliant:

– Flame retardant (IEC 60332-3 Cat. C)– Zero halogene (IEC 60754-1)– Smoke density (IEC 61034)– Corrosiveness of combustion gases (IEC 60754-1)

• Competitor manufacturers: Kabelwerk EUPEN - NOVACAVI

Page 6: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Possible cabling layout

Drawn by L. Roscilli

Page 7: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Possible cabling layout

Drawn by L. Roscilli

Page 8: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Barrel RPC: sector cables (except sectors 4-9-10-11)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4 RB4

6 LV 8 HV

To balconies

12

78 SGN6 DCS

To LBBOX

12

18 (12)

12 (18)

12

12

17p

17p

110p (17p)

17p

17p

Wheel 0, ±1 (Wheel ±2 )

18w

18w

112w (18w)

18w

18w

18w (112w) 17p (110p)

Page 9: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Barrel RPC: sector cables (sector 4)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4

7 LV 10 HV

To balconies

12

90 SGN7 DCS

To LBBOX

12

18(12)

12(18)

12

RB4 RB4 RB4

Wheel 0, ±1 (Wheel ±2 )

17p

17p

110p (17p)

17p

17p

17p (110p)

17p

18w

18w

112w (18w)

18w

18w

18w (112w)

18w

12

12

Page 10: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Barrel RPC: sector cables (sector 10)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4 RB4

7 LV 8 HV

To balconies

12

86 SGN7 DCS

To LBBOX

12

12

10

Wheel 0, ±1 (Wheel ±2 )

18w

18w

112w (18w)

18w

18w

18w (112w)

18w

18(12)

12(18)

17p

17p

110p (17p)

17p

17p

17p (110p)

17p

10

Page 11: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Barrel RPC: sector cables (sectors 9-11)

RB2_OUT

RB2_IN

RB1_OUT

RB1_IN

RB3 RB3

RB4

6 LV 7 HV

To balconies

12

72 SGN6 DCS

To LBBOX

12

12

6

Wheel 0, ±1 (Wheel ±2 )

18w

18w

112w (18w)

18w

18w

18w (112w)

18(12)

12(18)

17p

17p

110p (17p)

17p

17p

17p (110p)

Page 12: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Numbers and lengthsUpdated by F. Montecassiano

Page 13: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Numbers and lengthsUpdated by F. Montecassiano

Page 14: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Cables length specification (Wheel 0/ Z-)

updated by L. Roscilli

Page 15: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Cables length specification (Wheel 0/ Z+)

updated by L. Roscilli

Page 16: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Rack composition in USC

EASY4000

EASY3000

EASY4000

EASY3000

HV Patch Panel

1. SY1527:9 or 11 A1676 Branch Controllers

1. EASY crates2. HV modules (A3512):

7 modules/crate

Full Option:1020 HV channels

Chamber Option:480 HV channels

Station Option:360 HV channels

170 HV modules25 EASY crates+ 1 SY1527 + 20 HV patch panel

80 HV modules12 EASY crates+ 1 SY1527 + 20 HV patch panel

60 HV modules9 EASY crates+ 1 SY1527 + 20 HV patch panel

+

Page 17: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Rack position in USC

Page 18: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Rack composition in UXC

Calculation per quadrant (Barrel)• 3 LV modules (A3003)/quadrant (6 EASY crate slots)• Current absorption calculations:

– 2 Lbboxes x 13 LBs = 26 LBs– 1 Lbbox x 15 LBs = 15 LBs– 41 LBs/quadrant– Current absorption: 14A/LB (estimation)– 14A x 41 LBs = 574 A/quadrant– We need 6 A3100 CAEN LV module (4 slots width each)– We need a total of 24 slots 1 + 1/5 EASY crates per

tower– This fit with the 2 x 6U crates foreseen for RPC.

Page 19: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Rack composition in UXC towers

Page 20: RPC cabling

PaolucciINFN-Napoli

Muon Annul ReviewCern 15 September 2003 RPC cabling

Conclusions

• We are ready for asking a cable PRR– we are just collecting all necessary documentations

• Before the end of this year we start tenders– this implies to know exactly total lengths

• Open issues:– Cable path (to be approved very soon)