residential water heaters - bradford white · brute horizontal & vertical ... all gas water...
TRANSCRIPT
Residential Water HeatersGASAtmospheric Vent High EF ...................................................................................6/7Atmospheric Vent Damper...................................................................................8/9Atmospheric Vent Models................................................................................10/11Atmospheric Vent High Input...........................................................................12/13Direct Vent .......................................................................................................14/15TTW® Power Vent ............................................................................................16/17Power Direct Vent ............................................................................................18/19Manufactured Home Closed Combustion/Direct Vent......................................20/21Manufactured Home Atmospheric Combustion ...............................................22/23Ultra Low NOx Atmospheric Vent Damper.......................................................24/25Ultra Low NOx Atmospheric Vent ....................................................................26/27Ultra Low NOx Atmospheric Vent High Input...................................................28/29Ultra Low NOx TTW® Power Vent ....................................................................30/31Ultra Low NOx Power Direct Vent....................................................................32/33Ultra Low NOx Direct Vent ...............................................................................34/35Infiniti Tankless™ High Efficiency .....................................................................36/37Infiniti Tankless™ Mid Efficiency.......................................................................38/39
ELECTRICGeneral Information .........................................................................................40/41AeroTherm™ Series Heat Pump........................................................................42/43Upright Models ................................................................................................44/45Lowboy Models ...............................................................................................46/47Wall Hung ........................................................................................................48/49Utility ...............................................................................................................50/51Powerful Compact®..........................................................................................52/53KwickShot® Instantaneous Water Heaters .......................................................54-57
SOLAREcoStor2™ Double-Wall Gas Backup ................................................................58/59EcoStor2™ TTW® Power Vent Double-Wall Gas Backup...................................60/61EcoStor™ Open Loop Gas Backup ....................................................................62/63EcoStor™ TTW® Power Vent Open Loop Gas Backup.......................................64/65EcoStor2™ SC Ultra Low NOx Double-Wall Gas Backup ..................................66/67EcoStor™ Dual Coil Heat Exchanger Backup ....................................................68/69EcoStor™SC Single-Wall Electric Backup .........................................................70/71EcoStor2™ Double-Wall Electric Backup Models..............................................72/73Solar Saver® Electric Backup ...........................................................................74/75
HYDRONIC SPACE HEATINGCombi1™ Single-Wall Atmospheric ..................................................................76/77Combi1™ TTW® Single-Wall Power Vent Models .............................................78/79Combi2™ Double-Wall Atmospheric Models ....................................................80/81Combi2™ TTW® Double-Wall Power Vent.........................................................82/83
INDIRECTSPowerStor Series® Single-Wall Indirect ...........................................................84/85PowerStor2™ Series Double-Wall Indirect........................................................86/87Powertor Series® SS Stainless Steel Single-Wall Indirect................................88/89
STORAGE TANKSStorage Tank ....................................................................................................90/91
Commercial Water HeatersGASLight Duty Atmospheric Vent High Input .........................................................94/95Light Duty TTW® Power Vent...........................................................................96/97Light Duty Power Direct Vent ..........................................................................98/99Light Duty Direct Vent..................................................................................100/101Light Duty Ultra Low NOx Atmospheric Vent High Input .............................102/103Light Duty Ultra Low NOx Direct Vent .........................................................104/105
Light Duty Ultra Low NOx TTW® Power Vent...............................................106/107Light Duty Ultra Low NOx Power Direct Vent ..............................................108/109Commander Series™ Atmospheric Vent .......................................................110/111Electronic Ignition Water Heaters ................................................................112-115Induced Draft ...............................................................................................116/117Millivolt ........................................................................................................118-121Ultra High Efficiency Models........................................................................122-125
ELECTRICGeneral Information .....................................................................................126/127Electri-Flex™ LD (Light Duty) Upright...........................................................128/129Electri-Flex™ LD (Light Duty) Lowboy ..........................................................130/131Electri-Flex™ LD (Light Duty) Utility .............................................................132/133Electri-Flex™ LD (Light Duty) Wall Hung ......................................................134/135Electri-Flex™ MD (Medium Duty)..................................................................136/137Surface and Immersion Thermostat ............................................................138/139ASME Models ..............................................................................................140/141Brute Vertical Round....................................................................................142/143Brute Horizontal & Vertical ..........................................................................144-147GPH Recovery Table for kW Input ...............................................................148/149
INDIRECTSPowerStor Series® Single-Wall Indirect.......................................................150/151
STORAGE TANKSJacketed Storage Tank .................................................................................152/153Large Volume Jacketed Storage Tank..........................................................154-157Large Volume Unjacketed Storage Tank ......................................................158-161Large Volume Vertical Topcoat Storage Tank Models..................................162-165
WARRANTY INFORMATION............................................................................................166TANK TYPE SERIAL NUMBER INDENTIFICATION ..........................................................167
Contents / General Information
General Information1. All Gas Water Heaters are design certified by CSA International (formerly AGA and CGA) in accordance with ANSI Z21.10.1 or 10.3 (latest addition). Closed Combustion Manufactured Home Water
Heaters, are listed by Intertek (ETL).2. All Electric Water Heaters are listed by Intertek (ETL).3. All Residential Storage Models meet or exceed efficiency requirements of the Department of Energy. ASHRAE standard 90.1b (current standard) and the National Appliance Energy Conservation
Act of 1987, recent amendment effective April 16, 2015 which supercedes all state and local efficiency requirements.4. All Tank Type Water Heaters are certified at 300 PSI test pressure and 150 PSI working pressure (except where noted).5. All Residential and Light Duty Water Connections are 3⁄4" NPT on 8" centers (except where noted).6. All Residential and Light Duty Gas Models have 1⁄2" NPT Gas Connections (except where noted).7. All Residential Water Heaters come with a T&P Relief Valve included (except where noted).8. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560;
7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133;7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENTAPPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012.
9. All dimensions are in inches (unless otherwise noted). Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.10. All products manufactured by Bradford White Water Heaters are designed, fabricated, and assembled in Middleville, MI. All raw materials and component parts are sourced from American
companies for the highest level of American made content and manufacture, whenever possible.CSAInternational
Intertek
National Sanitation Foundation
American Society of Mechanical EngineersHeating Boilers
American Society ofMechanical Engineers LinedPotable Water Heaters
National Board ofBoiler and PressureVessel Inspectors
Air-Conditioning, Heating,and Refrigeration Institute
Compliance, Safety,Accountability
UnderwritersLaboratories
Hydrojet® Total Performance SystemThe Hydrojet® Total Performance System is a cold-water delivery tube that reduces sediment buildup and thoroughly mixes incoming water with stored water reducing thermalstratification. The secret is a series of flow altering “jet ports”.These ports create counter-rotation and dynamic turbulence that effectively blastssediment into suspension and prevents its accumulation.
The Hydrojet® Total Performance System also causes more efficient temperature mixinginside the tank. Heating efficiency and usable hot water delivery are greatly increased,thereby saving energy and money.
The upper “jet ports”direct the flowoutward to begin thedynamic mixing action.
The Hydrojet® System’s jet ports create a churning outflow that puts sediment intosuspension. This turbulent action helps reduce sediment and prevent its accumulation.
The Family of Hydrojet® SystemsThis Is Technology That Works!
The lower “jet ports”direct the flow inwardto increase pressureand turbulence.
Commercial Hydrojet® Sediment Reduction System The commercial Hydrojet® was designed to block the build-upof harmful sediment in commercial units by increasingturbulence with accelerated water current inside the tank.It incorporates up to two inlet tubes. One is the traditional topconnect version and the other is a front connection configuration.
Hydrojet®2 Total Performance SystemMuch like the original Hydrojet® Total Performance System, this cold water inlet deviceminimizes sediment build up, increases delivery and reduces thermal stratification.The Hydrojet®2 is specifically designed for higher input applications. It utilizes additionaljetports to initiate beneficial temperature mixing higher in the tank thereby increasing usable hot water.
“Make the Switch to Bradford White”
Residential Gas 6/7Atmospheric Vent High EF Models
■ ENERGY STAR® Qualified■ High Efficiency Blower
- 10 ft. power cord included (120 VAC)■ Bradford White ICON System™
- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Advanced ScreenLok® TechnologyFlame Arrestor Design
■ Flammable Vapor Sensor■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ 2" Non-CFC Foam Insulation
■ Pedestal Base.■ Water Connections—3⁄4" NPT
factory-Installed True Dielectric Fittings.■ Factory-Installed Heat Traps■ Protective Magnesium Anode Rod.■ 3x4 “Snap Lock” Draft Diverter■ T&P Relief Valve—Installed.■ Low Restriction Brass Drain Valve
C
A
G
E
D
F
B
H
Photo ofRG2F40S6N
38,00038,000
4050
★ RG2F40S6N★ RG2F50S6N
7084
541/4551/4
2224
40405/8
147178
113/4113/4
3 x 43 x 4
Atmospheric Vent High EF ModelsDIMENSIONS IN INCHES
NATURAL GAS AND LIQUID PROPANE GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.700.70
EnergyFactor
4141
NatU.S.GPH
3333
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.4748
F
Floor toTop ofHeater
477/8487/8
G
Floor toWaterConn.
257/8277/8
H
Depth
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.120V, 60Hz. 1 Amp.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.★ = ENERGY STAR® Qualified.
Residential Gas 8/9Atmospheric Vent Damper Models
■ ENERGY STAR® Qualified—Some models■ Bradford White ICON System™
- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Automatic Flue Damper- 10 ft. power cord included (120 VAC)
■ Advanced ScreenLok® TechnologyFlame Arrestor Design
■ Flammable Vapor Sensor■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Non-CFC Foam Insulation■ Pedestal Base.
■ Water Connections—3⁄4" NPT factory-Installed True Dielectric Fittings.
■ Factory-Installed Heat Traps■ Protective Magnesium Anode Rod.■ 3x4 “Snap Lock” Draft Diverter■ T&P Relief Valve—Installed.■ Low Restriction Brass Drain Valve
A
G
F
E
D
C
B
JH
Photo ofRG2D40S6N
32,00040,00040,00040,00038,00040,000
304040504050
RG1D30T6N• RG1D40S6N• RG1D40T6N• RG1D50T6N•★ RG2D40S6N★ RG2D50S6N
587476897286
63577/8633/8633/8541/2631/2
162018202222
497/841
501/8497/8407/8497/8
115141131157159172
13131313
113/4113/4
3 x 43 x 43 x 43 x 43 x 43 x 4
Atmospheric Vent Damper ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.650.620.620.600.670.67
EnergyFactor
344343434143
NatU.S.GPH
283636363436
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.561/448
569/16
569/16
4711/16
561/2
F
Floor toTop ofHeater
57491/8573/4573/4487/858
G
Floor toWaterConn.
203/4243/4223/4243/4261/8261/8
H
Depth88881111
J
C/L ofWaterConn.
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.120V, 60Hz. 12 Amps.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.★ = ENERGY STAR® Qualified.
• Models feature optional top T&P location and must be specified when ordering.
RG1D30T6X• RG1D40S6X• RG1D40T6X• RG1D50T6X•★ RG2D40S6X★ RG2D50S6X
LP GAS MODELS InputBTU/Hr.
31,00038,00038,00038,00038,00040,000
Recovery90°F Rise*
334141414143
LPU.S.GPH
283434343436
LPImp.GPH
ModelNumber
Residential Gas 10/11Atmospheric Vent Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Advanced ScreenLok® TechnologyFlame Arrestor Design
■ Resettable Thermal Switch■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ 2" Non-CFC Foam Insulation■ Pedestal Base.■ Water Connections—3⁄4" NPT Factory-
Installed True Dielectric Fittings.
■ Factory-Installed Heat Traps.■ Protective Magnesium Anode Rod.■ 3x4 “Snap Lock” Draft Diverter■ T&P Relief Valve—Installed. ■ Low Restriction Brass Drain Valve
A
F&G
D
E
F
C
B
8"
Photo ofRG240T6N
Now you have anincredible opportunityto increase yourprofits while providingan added value to thehomeowner.
Instantly upgrade a water heater to 10 yearsduring the installation – no need to changeANY components.
Available on selected Bradford White residential waterheaters from your Bradford White distributor.
Eligible Models LEVEL 2
GAS*RG140S**RG150L**RG150S**RG230TRG230SRG240TRG240S
RG250LRG250TRG250SURG230TURG240TURG240SURG250TURG250L
URG250SELECTRIC*RE120LRE230LRE240LRE250LRE230S**RE240S**
RE250S**RE265T**RE280T**RE330SRE340SRE340TRE350SRE350T
RE240SRE250SRE250SRE12URE16URE110URE112URE112T
RE115URE120URE16WVRE112WVRE120WV
GAS*RG2F40SRG2F50SRG250HRG275HRG2100HRG1D30TRG1D40SRG1D40TRG1D50TRG2D40SRG2D50S
RG2DV40SRG2DV50SRG2DV50HRG2MH30TRG2MH40TRG2DVMH30TRG2DVMH40TRG2PDV40SRG2PDV50SRG2PDV50HRG2PDV75HRG1PV40S
RG1PV50SRG2PV40TRG2PV50TRG2PV60T**RG2PV50HRG2PV75HURG250HURG275HURG2100HURG1D30TURG1D40SURG1D40T
URG1D50TURG2DV40SURG2DV50SURG1PV40SURG1PV50SURG2PV40TURG2PV50TURG2PV50HURG2PV75HURG2DV50HURG2PDV40SURG2PDV50S
URG2PDV50HELECTRIC*MS65RMS80RMS120R
Eligible Models LEVEL 1
* This Warranty Upgrade includes all of the associated suffixes to the base model numbers above. The Upgrade Kit alsoapplies to any corresponding new model numbers created.
** Available in Canada ONLY.
MAKE MORE MONEYON WATER HEATER INSTALLATIONS
A New Namein Tankless
fromBradford White
Discover Infiniti Introducing The NewHeat Pump Water Heater
from Bradford White
Get AeroTherm.Get Satisfied Customers.
Featuring 3.39 EF(Energy Factor) uses 62%less energy than a standard50-gallon electricwater heater
32,00030,00040,00040,00040,00040,00050,000
30304040485050
RG230T6N•RG230S6NRG240T6N•RG240S6N•RG250L6NRG250T6N•RG250S6N•
58567674888993
593/4491/4601/8511/2515/8601/2601/2
18202022242222
497/8385/8501/841
405/8497/8497/8
116113134139170154167
13131313131313
3 x 43 x 43 x 43 x 43 x 43 x 4
4
Atmospheric Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.640.630.620.620.600.620.60
EnergyFactor
34324343434354
NatU.S.GPH
28373636363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.571/8461/2579/16
493/16
493/8577/8583/16
F
Floor toWaterConn.
271/8N/A
579/16
493/16
N/A577/8583/16
G
Top T&P
Conn.
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.•Models feature optional top T&P location and must be specified when ordering.Note: RG230S6N and RG250L6N do not have top T&P option.Energy Factor and First Hour Rating is based on the latest AHRI directory listings. RG230T6X•
RG230S6XRG240T6X•RG240S6X•RG250L6XRG250T6X•RG250S6X•
LP GAS MODELS InputBTU/Hr.
31,00032,00036,00035,00035,00035,00048,000
Recovery90°F Rise*
33323441414152
LPU.S.GPH
23273334343445
LPImp.GPH
ModelNumber
Residential Gas 12/13Atmospheric Vent High Input Models
All Model Features (except RG155H6N):■ Bradford White ICON
System™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
ThermowellAll Model Features:■ Factory-Installed
Hydrojet 2™ TotalPerformance System
■ Vitraglas® Lining■ Side Connections—3/4"
(19mm)■ Non-CFC Foam
Insulation■ Pedestal Base
(RG250H6N /RG275H6N only)
■ Water Connections■ Hand Hole Cleanout
(RG2100H6N only)■ Protective Magnesium
Anode Rod.■ 4" (107mm) “Snap Lock”
Draft Diverter■ T&P Relief Valve—
Installed■ Low Restriction Brass
Drain Valve■ Thermostatic Mixing
Valve (ASSEApproved)—Includedwith RG155H6N only
KB
C
J
F
E L
A
D&M
H
N N
A
D&M
E
J F
B
H
N N
C
K
L
K
B
C
A
JF
E
D&M
L
NN
H
Photo ofRG2100H6NRG2100H6NRG250H6N / RG275H6N RG155H6N
65,00080,00076,00085,000
485575100
RG250H6NRG155H6NRG275H6NRG2100H6N
110N/AN/AN/A
60591/2625/869
222226
281/4
4915/16
497/8517/8595/16
193207263424
131413/16
15157/16
4444
Atmospheric Vent High Input ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Recovery90°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/AN/A
EnergyFactor
70868292
NatU.S.GPH
35726877
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.565/8
5515/16
59651/2
F
Floor toTop ofHeater
1181116
H
C/L ofWaterConn.
577/8577/8607/16
6615/16
J
Floor toWaterConn.
26257/8271/4311/2
K
Depth131/2157/16
165/81711/16
L
Floor toSpace
Heating Inlet4915/16
497/8517/8505/8
M
Floor toSpace
Heating Outlet3/43/41
11/4
N
NPT
Approx.Shipping
Weight (lbs)
*Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".For 10 year models, change suffix from "6" to "10". RG155H6N not available as 10 year model.RG2100H6N model features hand hole cleanout.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
RG250H6XRG155H6XRG275H6XRG2100H6X
LP GAS MODELS InputBTU/Hr.
61,00078,00076,00085,000
Recovery90°F Rise*
66848295
LPU.S.GPH
55706879
LPImp.GPH
ModelNumber
Residential Gas 14/15Direct Vent Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Closed Combustion■ Reinforced Seals■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Cast Aluminum Air Intake Boot■ Telescoping Solid Vent Kits■ Flexible Vent Kit■ Side Connections—3/4" NPT tappings
(RG2DV50H6N only)■ 2" Non-CFC Foam Insulation
■ Pedestal Base■ Water Connections—3/4" NPT—
Factory-Installed True Dielectric Fittings■ Factory-Installed Heat Traps
■ Protective Magnesium Anode Rod■ T&P Relief Valve—Installed■ Low Restriction Brass Drain Valve
J
H
F
E L
B
D&MK
C C
A A
K
Photo ofRG2DV50H6NFlexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)
38,00042,00050,000
405048
RG2DV40S6NRG2DV50S6NRG2DV50H6N
738893
633/8 min.
723/8 min.
725/16 min.
222222
433/8521/4521/4
189212234
151515
334
556
Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor to C/L of Vent
1st HourRating(Gal.)
0.620.600.60
EnergyFactor
414554
NatU.S.GPH
343545
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.503/16
593/16
591/8
F
Floor toTop ofHeater
8118
H
C/L ofWaterConn.
511/8601/8601/8
J
Floor toWaterConn.
313131
K
Depth——
153/4
L
Floor toSpace
Heating Inlet——
521/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
RG2DV40S6N / RG2DV50S6N Solid Vent Kit: Part No. 239-51283-00. RG2DV40S6N / RG2DV50S6N Flexible Vent Kit: Part No. 239-51284-00.RG2DV50H6N Solid Vent Kit: Part No. 239-51286-00. RG2DV50H6N Flexible Vent Kit: Part No. 239-51287-00.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and OperationManual. RG2DV40S6N / RG2DV50S6N Optional Telescoping Solid Vent Kits:Kit “A” Telescopes from 43⁄4" to 511⁄16" Part No. 239-41260-00Kit “B” Telescopes from 61⁄2" to 93⁄16" Part No. 239-41331-00Kit “C” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-41029-00Kit “D” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-41424-00RG2DV50H6N Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
RG2DV40S6XRG2DV50S6XRG2DV50H6X
LP GAS MODELS InputBTU/Hr.
36,00040,00048,000
Recovery90°F Rise*
394350
LPU.S.GPH
323642
LPImp.GPH
ModelNumber
Residential Gas 16/17TTW® Power Vent Models
■ ENERGY STAR® Qualified—Some Models■ Bradford White ICON System™
- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Power Vented Water Heater■ Powerful Blower Motor
- 10 ft. power cord included (120 VAC)■ Horizontal and Vertical Venting■ Advanced ScreenLok® Technology
Flame Arrestor Design ■ Flammable Vapor Sensor■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining
■ Non-CFC Foam Insulation■ Water Connections—3/4" NPT■ 3/4" NPT Side Connections
(RG2PV50H6N, RG1PV55H6N, andRG2PV75H6N only)
■ Factory-Installed Heat Traps■ Protective Magnesium Rod
(RG1PV55H6N has two)■ T&P Relief Valve—Installed■ Low Restriction Brass Drain Valve
Photo ofRG2PV50H6N
C
J
F
E L
A
D&M
B
H
K
40,00040,00040,00040,00065,00078,00076,000
40504050485575
RG1PV40S6N RG1PV50S6N★ RG2PV40T6N★ RG2PV50T6N★ RG2PV50H6N RG1PV55H6N RG2PV75H6N
72867286112N/AN/A
575/16
581/4667/8667/8661/8643/16
697/16
20222022222226
40405/85050
501/84715/16
511/2
140166146173187219260
113/4113/4113/4113/4113/4111/2131/2
2 or 32 or 32 or 32 or 33 or 43 or 43 or 4
TTW® Power Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
Recovery90°F Rise*
A
Floor to VentConn.
1st HourRating(Gal.)
0.660.650.700.700.70N/AN/A
EnergyFactor
43434343708482
NatU.S.GPH
36363636587068
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.471/2481/4563/4563/4563/8545/8591/2
F
Floor toTop ofHeater
888811811
H
C/L ofWaterConn.
49591/25858
573/456
603/4
J
Floor toWaterConn.
277/8263/4241/2261/2263/4261/2301/4
K
DepthN/AN/AN/AN/A131/2133/8133/8
L
Floor toSpace
Heating InletN/AN/AN/AN/A501/8
4715/16
511/2
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium StainlessSteel propane burner. For Propane (LP)models change suffix "N" to "X". For 10 yearmodels, change suffix from "6" to "10".RG1PV55H6N not available as 10 yearmodel.*Based on manufacturer’s ratedrecovery efficiency. 120 VAC Required forPower Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating is basedon the latest AHRI directory listings.★ = ENERGY STAR® Qualified.
2" Vent Pipe
RG1PV40S6NRG1PV50S6NRG2PV40T6NRG2PV50T6N
†50 ft.7 ft.45 ft.40 ft.35 ft.
3" Vent Pipe
†120 ft.15 ft.115 ft.110 ft.105 ft.
3" Vent Pipe
RG2PV50H6NRG1PV55H6NRG2PV75H6N
†50 ft.7 ft.45 ft.40 ft.35 ft.
4" Vent Pipe
†180 ft.15 ft.175 ft.170 ft.165 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
RG1PV40S6X RG1PV50S6X★ RG2PV40T6X★ RG2PV50T6X★ RG2PV50H6X RG1PV55H6X RG2PV75H6X
LP GAS MODELS InputBTU/Hr.
38,00038,00040,00040,00058,00078,00075,500
Recovery90°F Rise*
41414343628481
LPU.S.GPH
34343636527067
LPImp.GPH
ModelNumber
†For high altitude installations, consult the installation instructions.
Residential Gas 18/19Power Direct Vent Models
■ ENERGY STAR® Qualified—Some Models
■ Bradford White ICONSystem™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Closed Combustion Venting
System■ Powerful Blower Model
- 10 ft. power cord included(120 VAC)
■ Cast Aluminum Air IntakeBoot
■ Horizontal and VerticalVenting
■ Optional Concentric Vent KitTermination
■ Flammable Vapor Sensor(except RG2PDV75)
■ Factory-Installed Hydrojet®
■ Vitraglas® Lining■ 2" Non-CFC Foam Insulation■ Water Connections— 3⁄4"
NPT■ Side Connections— 3/4"
NPT (RG2PDV50H6N andRG2PDV75H6N only)
■ Factory-Installed Heat Traps■ Protective Magnesium
Anode Rod■ T&P Relief Valve—Installed■ Low Restriction
Brass Drain Valve Photo ofRG2PDV40S6N
K
C
H
J F
EL
B
D & M
A
40,00040,00060,00080,000
40504875
★ RG2PDV40S6N★ RG2PDV50S6N★ RG2PDV50H6N RG2PDV75H6N
7286100—
5911/16
607/86972
22242226
421/2
431/2
521/4541/4
161192204291
1414
135/8161/4
2 or 32 or 33 or 43 or 4
Power Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor toExhaustOutlet
1st HourRating(Gal.)
0.700.700.68—
EnergyFactor
43436586
NatU.S.GPH
36365472
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.491/2501/2583/4623/4
F
Floor toTop ofHeater
593/8603/867
703/8
H
Floor toAir
Intake5013/16
5113/16
60633/4
J
Floor toWaterConn.
301/2321/2305/836
K
Depth——
153/419
L
Floor toSpace
Heating Inlet——
521/4541/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stabilized StainlessSteel propane burner. For Propane (LP) models changesuffix "N" to "X".For 10 year model, change suffix “6” to “10”. *Based on manufacturer’s rated recovery efficiency.120 VAC Required for Power Venting / 120 VAC, 60HZ,3.1 Amperes.Energy Factor and First Hour Rating is based on thelatest AHRI directory listings.★ = ENERGY STAR® Qualified.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
Concentric Vent KitTermination
2" Kit
P/N 239-44069-02 29 1/4
A (in.)
3" Kit
P/N 239-44069-01 36 1/4
A (in.)
2" Vent PipeRG2PDV40S6NRG2PDV50S6N
35 ft.35 ft.7 ft.30 ft.25 ft.20 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
3" Vent PipeRG2PDV40S6NRG2PDV50S6N
RG2PDV50H6NRG2PDV75H6N
85 ft.85 ft.7 ft.80 ft.75 ft.70 ft.
60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.
4" Vent PipeRG2PDV50H6NRG2PDV75H6N
100 ft.100 ft.7 ft.
95 ft.90 ft.85 ft.
★ RG2PDV40S6X★ RG2PDV50S6X★ RG2PDV50H6X RG2PDV75H6X
LP GAS MODELS InputBTU/Hr.
38,00038,00060,00078,000
Recovery90°F Rise*
41416584
34345470
LPU.S.GPH
LPImp.GPH
ModelNumber
Residential Gas 20/21Manufactured Home Closed Combustion/Direct Vent Models
■ Housing and Urban Development■ Sealed Combustion Roof Jack Kit—
must order for new installations■ Flue Baffle■ Heat Traps■ Vitraglas® Lining■ Fully Automatic Controls■ 2" Non-CFC Foam Insulation■ Water Connections—3⁄4" NPT■ Protective Magnesium Anode Rod■ T&P Relief Valve—Installed■ Low Restriction Brass Drain Valve■ Convertible Gas Control
Photo ofRG2DVMH30T6X
C
G
A
E
F
D
B
30,00030,000
3040
RG2DVMH3OT6XRG2DVMH4OT6X
5259
579/16
571/41820
501/4501/2
119139
133/4133/4
33
Manufactured Home Closed Combustion/Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS AND LIQUID PROPANE GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed76% Recovery Efficiency
Recovery90°F Rise*
A
Floor toTop ofHeater
1st HourRating(Gal.)
0.630.62
EnergyFactor
3232
NatU.S.GPH
2727
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floorto T&PConn.
E
Floor toGas
Conn.221/2221/2
F
Floor toCold Water
Conn.571/258
G
Floor toHot Water
Conn.
Approx.Shipping
Weight (lbs)
To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Optional Roof Jack Kits
Part Number12"
18" / 32"32" / 60" 48" / 90"
239-37022-01239-37022-02239-37022-03239-37022-04
A15"
331/2"321/2"- 621/2"
50"- 981/2"
BThrough The Roof
Clearance16"- 33"
331/2"- 66"371/2"- 74"
541/2"- 1091/2"
(Includes: roof jack, hardware, air intake, instructions).B
22.5° Max.
A11 5/8"Square
6 1/2"
7"
4"
5"
3"
9"
This water heater is of the closed combustion type (directventing) for mobile home applications only, where allcombustion air is supplied from the outdoors throughthe air intake and all combusted gas products are venteddirectly to the outside by means of the roof jack. No draftdiverter (vent hood) is required for this water heater. TheETL listing of this water heater includes the fieldinstallation of the following components: roof jack, roofjack clamp, air intake, air intake seal, and heater tie downmaterials. These components for field installation areshipped with the heater in a separate box and must beinstalled according to instructions. No other componentsare approved for use with the water heater. The waterheater must be installed in accordance with The FederalMobile Home Construction and Safety Standard or in theabsence of such standard, The Standard for MobileHomes (ANSI/NFPA No. 601B-1977)
Residential Gas 22/23Manufactured Home Atmospheric Combustion Models
■ Advanced ScreenLok® TechnologyFlame Arrestor Design
■ Resettable Thermal Switch■ Piezo Igniter■ Pedestal Base■ Maintenance-Free■ Sight Window■ Housing and Urban Development■ Roof Jack Kit—Must order for new
installations■ Vitraglas® Lining■ Fully Automatic Controls■ Convertible Gas Control■ 2" Non-CFC Foam Insulation■ Water Connections—3⁄4" NPT■ Heat Trap
■ Protective Magnesium Anode Rod■ 3"x4" “Snap Lock” Draft Diverter■ Flue Baffle■ Steel Tank■ T&P Relief Valve■ Low Restriction Brass Drain Valve■ Design Certified by CSA International
(formerly AGA/CGA).
Photo ofRG2MH30T6X
C
G
A
H
E
F
D
B
K
32,00034,000
3040
RG2MH30T6XRG2MH40T6X
5557
591/8593/8
1820
505/16
505/16
118135
1313
3 x 43 x 4
Manufactured Home Atmospheric Combustion ModelsDIMENSIONS IN INCHES
NATURAL GAS AND LIQUID PROPANE GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed77% Recovery Efficiency
Recovery90°F Rise*
A
Floor toFlue Conn.
1st HourRating(Gal.)
0.630.63
EnergyFactor
3437
NatU.S.GPH
2831
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toCold Water
Conn.221/2221/2
F
Floor toHot Water
Conn.573/4573/4
G
Floor toHeater
Top2022
K
Depth567/8567/8
H
Floor toHeater
Top
Approx.Shipping
Weight (lbs)
To order Natural Gas heaters change “X” to “N”. For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Optional Roof Jack Kits
Part Number12"
18" / 32"32" / 60" 48" / 90"
239-37030-01239-37030-02239-37030-03239-37030-04
A15"
331/2"321/2"- 621/2"
50"- 981/2"
BThrough The Roof
Clearance16"- 33"
331/2"- 66"371/2"- 74"
541/2"- 1091/2"
(Includes: roof jack, hardware, air intake, instructions). B
22.5° Max.
A11 5/8"Square
6 1/2"
7"
4"
5"
3"
9"
The water heater enclosure access door mustbe on the outside wall of the manufacturedhome (mobile home) only. Access to thewater heater enclosure from the inside of themanufactured home (mobile home) is notpermitted. The CSA International (formerlyAGA/CGA) listing of this water heater includesthe field installation of the followingcomponents: roof jack and heater tie downmaterials. These components for fieldinstallation are shipped in a separate boxfrom the heater and must be installedaccording to instructions. No othercomponents are approved for use with thewater heater. The water heater must beinstalled in accordance with The FederalManufactured Home Construction and SafetyStandard Title 24 CRF, Part 3280.
Residential Gas 24/25Ultra Low NOx Atmospheric Vent Damper Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Automatic Flue Damper- 10 ft. power cord included (120 VAC)
■ Defender Combustion Chamber■ Ultra Low NOx Burner with Primary
and Secondary Air Distribution Devices■ Digital Thermal Sensor and Resettable
Thermal Switch■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining■ 1" Non-CFC Foam Insulation
■ Pedestal Base■ Water Connections—3⁄4" NPT ■ Factory-Installed Heat Traps■ Protective Magnesium Anode Rod■ 3x4 “Snap Lock” Draft Diverter■ T&P Relief Valve—Installed. ■ Low Restriction Brass Drain Valve■ Design Certified by CSA International
(formerly AGA and CGA).■ Complies with the latest Ultra Low NOx
requirement (10 ng/J NOx limit).
Photo ofURG1D50T6N
C
A
F
E
D
B
G
32,00040,00040,00040,000
30404050
URG1D30T6NURG1D40S6NURG1D40T6NURG1D50T6N
58747689
635413/16
639/16
633/8
16201820
497/841
501/8497/8
118147135159
113/4113/4113/4113/4
3 x 43 x 43 x 43 x 4
Ultra Low NOx Atmospheric Vent Damper ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor toFlue
Conn.
1st HourRating(Gal.)
0.650.620.620.60
EnergyFactor
34434354
NatU.S.GPH
25363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toGas
Conn.571/8491/8571/2577/8
F
Floor toWaterConn.
203/4243/4223/4243/4
G
Depth
Approx.Shipping
Weight (lbs)
Available in Natural Gas only.For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Residential Gas 26/27Ultra Low NOx Atmospheric Vent Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Defender Combustion Chamber■ Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devices■ Digital Thermal Sensor and Resettable
Thermal Switch■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ 2" Non-CFC Foam Insulation■ Pedestal Base■ Water Connections—3⁄4" NPT
■ Factory-Installed Heat Traps■ Protective Magnesium Anode Rod■ 3x4 “Snap Lock” Draft Diverter■ Flue Baffle■ Steel Tank■ T&P Relief Valve—Installed■ Low Restriction Brass Drain Valve■ Design Certified by CSA International
(formerly AGA and CGA).■ Complies with the latest
Ultra Low NOx requirement (10 ng/J NOx limit).
Photo ofURG250T6N
C
F
E
D
A
●
B
G
32,00040,00040,00040,00040,00050,000
304040504850
URG230T6N•URG240T6N•URG240S6N•URG250T6N•URG250L6NURG250S6N•
587674908893
597/8601/4515/8603/16
515/8591/2
182022222422
497/85041
497/8405/8497/8
121139146161172167
113/4113/4113/4113/4113/4113/4
3 x 43 x 43 x 43 x 43 x 4
4
Ultra Low NOx Atmospheric Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
Recovery90°F Rise*
A
Floor toFlue
Conn.
1st HourRating(Gal.)
0.640.620.620.620.600.60
EnergyFactor
344343434354
NatU.S.GPH
253636363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toGas
Conn.57
571/2491/8585/16
493/8583/16
F
Floor toWaterConn.
211/2231/2251/2251/2271/2251/2
G
Depth
Approx.Shipping
Weight (lbs)
Available in Natural Gas only.For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.•Models feature optional top T&P location and must be specified when ordering.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Residential Gas 28/29Ultra Low NOx Atmospheric Vent High Input Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Defender Combustion Chamber(URG250H6N only)
■ Ultra Low NOx Burner with Primaryand Secondary Air DistributionDevices
■ Digital Thermal Sensor andResettable Thermal Switch(URG250H6N only)
■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Side Connections—3/4" NPT
■ Non-CFC Foam Insulation■ Pedestal Base■ Water Connections■ Factory-Installed Heat Traps■ Protective Magnesium
Anode Rod■ 4" (107mm) “Snap Lock”
Draft Diverter.■ T&P Relief Valve■ Low Restriction Brass
Drain Valve■ Design Certified by CSA
International (formerly AGA and CGA).
■ URG250H6N complies with the latest Ultra Low NOx requirement (10 ng/J NOx limit) URG275H6N / URG2100H6N complies with (14 ng/J NOx limit). Photo of
URG250H6N
BK
C
L
J
H
E F
A
D&G
M
B
C
K
A
J
E F
G
D
L
M
Models URG250H6N & URG275H6N Model URG2100H6N
55,00076,00085,000
4875100
URG250H6NURG275H6NURG2100H6N
100N/AN/A
605/16
641/8707/16
2226
281/4
497/8539/16
607/16
194286416
111/2151/8163/4
444
Ultra Low NOx Atmospheric Vent High Input ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedRecovery efficiency up to 80%
Recovery90°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/A
EnergyFactor
598292
NatU.S.GPH
496877
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
133/8165/8183/4
F
Floor toSpace
HeatingReturn
497/8539/16
513/4
G
Floor toSpace
HeatingOutlet
563/8601/868
H
Floor toTop ofHeater
5713/16
611/8691/8
J
Floor toWaterConn.
257/16
297/16
311/2
K
Depth
111116
L
C/L ofWaterConn.
3/41
11/4
M
NPT
Approx.Shipping
Weight (lbs)
Available in Natural Gas only.For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Residential Gas 30/31Ultra Low NOx TTW® Power Vent Models
■ ENERGY STAR® Qualified■ Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devices■ Defender Combustion Chamber■ Flammable Vapor Sensor and
Resettable Thermal Switch (excludingURG2PV75H6N)
■ Maintenance-Free■ Sight Window■ Bradford White ICON System™
■ Enhanced Performance■ Advanced Temperature Control System■ Intelligent Diagnostics■ Separate Immersed Thermowell■ Powerful Blower Motor
- 10 ft. power cord included (120 VAC)■ Horizontal and Vertical Venting■ Factory-Installed Hydrojet® Total
Performance System
■ Vitraglas® Lining■ Non-CFC Foam Insulation■ Water Connections■ Factory-Installed Heat Traps■ Protective Magnesium Anode Rod.■ Pedestal Base. ■ T&P Relief Valve■ Low Restriction Brass Drain Valve■ All models comply with the latest
Ultra Low NOx requirement (10 ng/J NOx limit) exceptURG2PV75H6N (14 ng/J NOx limit).
Photo ofURG1PV40S6N
C
A
G
E
D
F
BH
J
40,00040,00040,00040,00056,00076,000
405040504875
URG1PV40S6N URG1PV50S6N★ URG2PV40T6N★ URG2PV50T6N★ URG2PV50H6N URG2PV75H6N
7286728699N/A
571/4581/4667/8667/8663/8691/4
202220222226
40405/8497/8497/8497/8517/8
144169151176192270
113/4113/4113/4113/4113/4113/4
2 or 32 or 32 or 32 or 33 or 43 or 4
Ultra Low NOx TTW® Power Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
Recovery90°F Rise*
A
Floor toVent
Conn.
1st HourRating(Gal.)
0.660.650.700.700.70N/A
EnergyFactor
434343436082
NatU.S.GPH
363636365068
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.471/8481/8565/8565/8565/8591/2
F
Floor toTop ofHeater
481/2491/258585861
G
Floor toWaterConn.
247/8267/8247/16
267/16
261/2301/4
H
Depth88881111
J
C/L ofWaterConn.
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”.*Based on manufacturer’s rated recovery efficiency.120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating is based on the latest AHRI directory listings.★ = ENERGY STAR® Qualified.
2" Vent Pipe
URG1PV40S6NURG1PV50S6NURG2PV40T6NURG2PV50T6N
3" Vent Pipe 3" Vent Pipe
URG2PV50H6NURG2PV75H6N
4" Vent Pipe
†50 ft.7 ft.45 ft.40 ft.35 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
†120 ft.15 ft.115 ft.110 ft.105 ft.
†50 ft.7 ft.45 ft.40 ft.35 ft.
†180 ft.15 ft.
175 ft.170 ft.165 ft.
†For high altitude installations, consult the installation instructions.
Residential Gas 32/33Ultra Low NOx Power Direct Vent Models
■ ENERGY STAR® Qualified■ Ultra Low NOx Burner with Primary and
Secondary Air Distribution Devices■ Closed Combustion Venting System■ Bradford White ICON System™
- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Cast Aluminum Air Intake Boot■ Flammable Vapor Sensor■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Powerful Blower Model
- 10 ft. power cord included (120 VAC)■ Optional Concentric Vent Kit Termination
■ Horizontal and Vertical Venting■ 2" Non-CFC Foam Insulation■ Water Connections— 3⁄4" NPT ■ 3/4" NPT Side Connections—
(URG2PDV50H6N only).■ Factory-Installed Heat Traps■ Protective Magnesium Anode
Rod.■ T&P Relief Valve
■ Low Restriction Brass Drain Valve■ Complies with the latest Ultra Low NOx
requirement (10 ng/J NOx limit).
Photo ofURG2PDV50H6N
A
JF
EL
B
D & M
C
H
K
N
40,00040,00050,000
405048
★ URG2PDV40S6N★ URG2PDV50S6N★ URG2PDV50H6N
728692
591/2
601/2691/4
222422
423/8
43521/4
159189201
137/8137/8137/8
2 or 32 or 33 or 4
Ultra Low NOx Power Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor toExhaustOutlet
1st HourRating(Gal.)
0.700.700.68
EnergyFactor
434364
NatU.S.GPH
363645
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor toT&P
Conn.
E
Floor toGas
Conn.
493/4603/8691/4
F
Floor toTop ofHeater
593/8503/4583/4
H
Floor toAir
Intake
515260
J
Floor toWaterConn.
303/4323/432
K
Depth
——
153/4
L
Floor toSpaceHeatingReturn
——
521/4
M
Floor toSpaceHeatingSupply
101/2111/291/4
N
C/L Distance
From Intaketo Exhaust
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 10 year model, change suffix "6" to "10".*Based on manufacturer’s rated recovery efficiency. 120 VAC Required forPower Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First HourRating is based on the latest AHRI directory listings.★ = ENERGY STAR® Qualified.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
Concentric Vent KitTermination
2" Kit
P/N 239-44069-02 29 1/4
A (in.)
3" Kit
P/N 239-44069-01 36 1/4
A (in.)
2" Vent Pipe
URG2PDV40S6NURG2PDV50S6N
35 ft.35 ft.7 ft.30 ft.25 ft.20 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
3" Vent Pipe
URG2PDV40S6NURG2PDV50S6N URG2PDV50H6N
85 ft.85 ft.7 ft.80 ft.75 ft.70 ft.
60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.
4" Vent Pipe
URG2PDV50H6N
100 ft.100 ft.7 ft.
95 ft.90 ft.85 ft.
Subtract 5ft. for each additional 90º elbow.
Residential Gas 34/35Ultra Low NOx Direct Vent Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Ultra Low NOx Burner with Primary
and Secondary Air Distribution Devices■ Closed Combustion■ Reinforced Seals■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Cast Aluminum Air Intake Boot■ Telescoping Solid Vent Kits■ Flexible Vent Kit
■ Side Connections—3/4" NPT ■ 2" Non-CFC Foam Insulation■ Pedestal Base.■ Water Connections—3/4" NPT ■ Factory-Installed Heat Traps.■ Protective Magnesium Anode Rod.
■ T&P Relief Valve■ Low Restriction Brass Drain Valve■ Design Certified by CSA International
(formerly AGA and CGA).■ Complies with the latest Ultra Low NOx
requirement (10 ng/J NOx limit).
Photo ofURG2DV50H6N
J
H
F
E
B K K
AA
C C
L
D&M
Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)
Available in Natural Gas only. For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
URG2DV40S6N / URG2DV50S6N Solid Vent Kit: Part No. 239-51283-00. URG2DV40S6N / URG2DV50S6N Flexible Vent Kit: Part No. 239-51284-00.URG2DV50H6N Solid Vent Kit: Part No. 239-51286-00. URG2DV50H6N Flexible Vent Kit: Part No. 239-51287-00.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installation and Operation Manual.
URG2DV40S6N / URG2DV50S6N Optional Telescoping Solid Vent Kits: URG2DV50H6N Optional Telescoping Solid Vent Kits:Kit “A” Telescopes from 43⁄4" to 511⁄16" Part No. 239-41260-00 Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “B” Telescopes from 61⁄2" to 93⁄16" Part No. 239-41331-00 Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “C” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-41029-00 Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “D” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-41424-00 Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
38,00038,00045,000
405048
URG2DV40S6NURG2DV50S6NURG2DV50H6N
738488
633/8651/2
741/4
222222
433/8521/4521/4
198221240
151515
334
556
Ultra Low NOx Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery90°F Rise*
A
Floor to C/L of Vent
1st HourRating(Gal.)
0.620.600.60
EnergyFactor
414146
NatU.S.GPH
343438
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.501/4591/4591/4
F
Floor toTop ofHeater
8811
H
C/L ofWaterConn.
511/2601/2601/8
J
Floor toWaterConn.
311/8311/8305/8
K
Depth——
153/4
L
Floor toSpace
Heating Inlet——
521/4
M
Floor toSpace
Heating Onlet
Approx.Shipping
Weight (lbs)
Residential Gas 36/37Infiniti Tankless™ High Efficiency Models
■ Featuring the SRT™
Scale ReductionTechnology- Vertical Modulating
Burner Design- Dual Fan
Configuration- Internal Turbulators- Dual Heat
Exchanger■ Built-In Digital
Control■ Active Bypass■ Cascading Kit
(Optional)■ Venting Flexibility
■ Gas ConnectionFlexibility—1/2", 3/4",or 1"
■ Inlet Water Filter■ Space Saving
Installation■ Built-In Freeze
Protection■ Interior and Exterior
Installation Capability■ Complies with the
latest Ultra-Low NOxrequirement (10 ng/JNOx limit).
Photo ofRTG-199HE-N
D
OptionalIntake
Intake
J
L
M
K
5 /1 2" 5 /1 2"
G H
I
Exhaust
C
B A
19,900–199,900Indoor / Outdoor*RTG-199HE-N 3 0.95 140º F0.5
Infiniti Tankless™ High Efficiency ModelsDIMENSIONS IN INCHES Meet or exceed ASHNATURAL GAS AND LIQUID PROPANE GAS MODELS
VentConn.
Recovery90°F Rise*
GPM
4.2
InputBTU/Hr.Installation
ModelNumber
EF RatingNat.
MinimumWater Flow
GPM
MaximumTemperature
Setting
309/16RTG-199HE-N 74
A
Height1713/16
B
Width107/16
C
Depth53/16
D
Intake/Exhaust
Center Line69/16
G
HotWaterOutlet
61/8
H
ColdWaterInlet
65/16
I
HotWaterOutlet
211/16
J
GasConn.
23/8
K
CondensateTee
25/8
L
CondensateTee
23/8
L
GasConn
ModelNumber
Approx.Shipping
Weight (lbs)
For Propane (LP) Models change suffix "N" to "X".Requires an electrical power supply from a 120VAC 60Hz properly rated receptacleand must be properly grounded. Power supply cord provided. *Outdoor installation requires optional outdoor kit
2" Venting
Twin Pipe
9.5 ft.9.5 ft.19.0 ft.5.0 ft.2.5 ft.
1
Max. Allowable Exhaust Vent LengthMax. Allowable Intake Vent LengthCombined Max. Allowable VentElbow Equivalency 90ºElbow Equivalency 45ºNumber of 90° Elbows
3" Venting
Twin Pipe Concentric
31.0 ft.31.0 ft.62.0 ft.5.0 ft.2.5 ft.
5
23.0 ft.23.0 ft.46.0 ft.5.0 ft.2.5 ft.
4
Twin Pipe Concentric
63.0 ft.63.0 ft.126.0 ft.5.0 ft.2.5 ft.
7
43.0 ft.43.0 ft.83.0 ft.5.0 ft.2.5 ft.
7
4" Venting
Residential Gas 38/39Infiniti Tankless™ Mid Efficiency Models
■ Featuring the SRT™ Scale ReductionTechnology- Vertical Modulating Burner Design- Dual Fan Configuration- Internal Turbulators- Dual Heat Exchanger
■ Built-In Digital Control■ Cascading Kit (Optional)■ Gas Connection Flexibility—1/2", 3/4",
or 1"■ Inlet Water Filter■ Space Saving Installation■ Built-In Freeze Protection■ Interior and Exterior Installation
Capability■ Complies with the latest Ultra-Low NOx
requirement (10 ng/J NOx limit). Photo ofRTG-199ME-N
B A
C
J
L
M
K
G H
I
D
5 /1 2" 5 /1 2"
OptionalIntake
Intake Exhaust
19,900–199,900Indoor / Outdoor*RTG-199ME-N 3 0.83 140º F0.5
Infiniti Tankless™ Mid Efficiency ModelsDIMENSIONS IN INCHES Meet or exceed ASHNATURAL GAS AND LIQUID PROPANE GAS MODELS
VentConn.
Recovery90°F Rise*
GPM
3.7
InputBTU/Hr.Installation
ModelNumber
EF RatingNat.
MinimumWater Flow
GPM
MaximumTemperature
Setting
309/16RTG-199ME-N 67
A
Height1713/16
B
Width107/16
C
Depth53/16
D
Intake/Exhaust
Center Line69/16
G
HotWaterOutlet
61/8
H
ColdWaterInlet
65/16
I
HotWaterOutlet
211/16
J
GasConn.
23/8
K
CondensateTee
25/8
L
CondensateTee
23/8
L
GasConn
ModelNumber
Approx.Shipping
Weight (lbs)
For Propane (LP) Models change suffix "N" to "X".Requires an electrical power supply from a 120VAC 60Hz properly rated receptacleand must be properly grounded. Power supply cord provided.*Outdoor installation requires optional outdoor kit
3" Venting
28.5 ft.28.5 ft.57.0 ft.5.0 ft.2.5 ft.
5
Max. Allowable Exhaust Vent LengthMax. Allowable Intake Vent LengthCombined Max. Allowable VentElbow Equivalency 90ºElbow Equivalency 45ºNumber of 90° Elbows
4" Venting
61.25 ft.61.25 ft.122.5 ft.5.0 ft.2.5 ft.
7
Residential Electric Energy Saver 40/41Water Heaters
All models are ETL listed. All water connections are 3⁄4" NPT factory-installed true dielectric fittings(RE120L). All electrical connections are 3⁄4". All models are certified at 300 psi test pressure and 150 psi working pressure.All models come equipped with two installed heat traps (except Utility, Wall Hung models, and RE120L).Note: The Upright and Lowboy heaters will be wired single phase interlocking (non-simultaneous) 240 volt with 4500 wattelements, unless otherwise specified. Other wattages are available up to 6000 watts (208, 240, 277 and 480 volt).(Reference chart on following page for non-simultaneous and simultaneous limitations). 4500 watt/240 volt elementsrequire a 25 amp or 30 amp circ uit breaker. For 120 volt (non-simultaneous), all models have a maximum wattage of 3000.(120 and 277 volt can only be wired single phase.)
Note: The Utility and Wall Hung Heaters will be wired for 120 volt with a 1500 watt element. The 1500 watt/120 voltelement requires a 20 amp breaker. Other wattages are available. Maximum wattage for 6 and 12 gallon tall utility modelsis 3000W. Maximum wattage for 10, 12 and 15 gallon utility models is 6000W. Maximum wattage for the 6 gallon wallhung model is 3000W. Maximum wattage for 12, 20 and 30 gallon wall hung models is 6000W.
General
Incoloy Element Availability Chart
yesnonononononononono
120V1500200025003000350040004500500055006000
Wattsyesyesyesyesyesyesyesyesyesyes
208Vyesyesyesyesyesyesyesyesyesyes
240Vnoyesnoyesnoyesyesyesyesyes
277Vnoyesnoyesnoyesyesyesyesyes
480V
VoltageWattage
Limitations forSimultaneous
Operation
1500W / 1500W2000W / 2000W2500W / 2500W3000W / 3000W3500W / 3500W4000W / 4000W4500W / 4500W5000W / 5000W5500W / 5500W6000W / 6000W
yesnonononononononono
120V
yesyesyesyesyesyesyesyesnono
208V
yesyesyesyesyesyesyesyesyesno
240V
yesyesyesyesnoyesyesyesnoyes
277V
yesyesyesyesnoyesyesyesnoyes
480V
VoltageWattage
Limitations forNon-Simultaneous
Operation
1500W / 1500W2000W / 2000W2500W / 2500W3000W / 3000W3500W / 3500W4000W / 4000W4500W / 4500W5000W / 5000W5500W / 5500W6000W / 6000W
WattageLimitations forSingle Element
Operation
1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W
yesyesyesyesnononononono
120V
yesyesyesyesyesyesyesyesyesyes
208V
yesyesyesyesyesyesyesyesyesyes
240V
yesyesyesyesnoyesyesyes
yes**yes
277V
yesyesyesyesnoyesyesyes
yes**yes
480V
DesignatorVoltage
A120
E277
H480
J600
L*208
C208/240
DesignatorWatt
J1000
K1250
L1500
M2000
N2500
P3000
R3500
S3800
T4000
W4500
X5000
Y5500
Z6000
Phase 13
Single PhaseThree Phase
Operation NS
Non-simultaneousSimultaneous
Designator240V Wattage208V Wattage
J1000—
K1250—
L15001000
M20001500
N25002000
P3000—
R35002500
S3800—
T40003000
W45003500
X5000—
Y55004000
Z60004500
X**—
5000
Y**—
5500†
Z**—
6000†
EX: RE340T6-1NCWW
EX: RE340T6-1NCWW
EX: RE340T6-1NCWW
EX: RE340T6-1NCWW =, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of 3500W/3500W.*Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.†Available in non-simultaneous only.
EX: RE340T6-1NCWW*Use “L” voltage designator if wiring 208V with 5000, 5500or 6000 watt.
For 120V, 277V, 480V, and 600V operation
For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)
**Incoloy element only.
Residential Electric 42/43AeroTherm™ Series Heat Pump Models
■ ENERGY STAR® Qualified■ The AeroTherm™ Series Control
Panel- User-Friendly, Easy-to-Read
Display.- LED’s Clearly Indicate the Current
Operating Mode.- Display Communicates Current
Status, Mode and Set Point, andDisplays Error Messages whenApplicable.
■ Operating Modes Offer Flexibility.- Heat Pump (Only) Mode- Hybrid Mode- Electric (Only) Mode- Vacation Mode
■ Quiet Operation■ Can Be Laid Down for Easier
Transportation
■ Easily Accessible Top MountedWashable Air Filter
■ Operating Air Temperature Range of35-120°F for the Heat Pump
■ Backup Electric Heating Elements.■ Direct Heat Transfer with Immersed
Elements■ 2" Non-CFC Foam Insulation■ Water Connections—3/4" NPT■ Protective Magnesium Alloy Anode
Rod■ T&P Relief Valve—Installed.■ Low Restriction Brass Drain Valve■ Design Certified to NSF/ANSI 372
(Lead Content).■ Northern Climate Tier 3 Capable.■ Optional Ducting Kit
Photo ofRE2H50R10B
AC
D
B
EF
6994
5080
RE2H50R10BRE2H80R10B
591/8711/8
213/425
88
195235
463/4583/4
603/4731/2
AeroTherm™ Series Heat Pump ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS C.E.C. Listed
Recovery90°F Rise*
A
Floor toHeater Top
3.393.26
EnergyFactor
2121
NatU.S.GPH
1818
NatImp.GPH
1st Hour**Delivery Rating
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
D
Distance Between
Water Conn.
E
Floor toCondensate
Conn.383/4503/8
F
Floor toT&P
Heater
Approx.Shipping
Weight (lbs)
*Based on 4500/4000W, Non-Simultaneous Operation. Optional Ducting Kit: Part No. GVK8HS.Kit installation also requires 8" insulated flexible ducting,ducting support hangers, and exterior wall vents for inlet& outlet. Additional clearances required for ducting, referto ducting kit instructions.
PARTS INCLUDED
Upper Inlet Duct Adapter
Lower Inlet Duct Adapter
Inlet Duct Filter
Outlet Duct Adapter
Drilling Screws (6)
8” Hose Clamps (2)
Assembly Screws (8)
Residential Electric 44/45Upright Models
■ DOE—Meet or Exceed EfficiencyRequirements
■ Fully Automatic Controls■ Direct Heat Transfer with Immersed
Elements■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Non-CFC Foam Insulation■ Water Connections—3⁄4" NPT ■ Factory-Installed Heat Traps ■ Protective Magnesium Anode Rod■ Simultaneous and Non-Simultaneous
Operation Available■ Voltages Available—120V, 208V, 240V,
277V, 480V.■ Single Phase or Three Phase Operation
Available—120V & 277V
■ T&P Relief Valve■ Design Evaluated by ETL in Accordance
with Part 280.707(d) of HUD MobileHome Construction and Safety Standards for Energy Efficiency.
Photo ofRE250S6
C
A
D
B
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
47555667675567
30404050504050
RE330S6RE340S6RE340T6RE350S6RE350T6RE240S6†RE250S6†
47477/8605/847
585/84847
20222024222022
100114125144138123143
473/4485/8613/8473/4593/8483/4473/4
Upright ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS C.E.C. Listed
Recovery90°F Rise*
A
Floor toHeater Top
0.950.950.950.950.950.950.95
EnergyFactor
21212121212121
NatU.S.GPH
18181818181818
NatImp.GPH
1st Hour**Rating(Gal.)
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
473/4485/8613/8473/4593/8483/4473/4
D
Floor toT&P
Heater
Approx.Shipping
Weight (lbs)
†Models include supplied insulation blanket (2" thick). Dimensions in charts above do notinclude blanket thickness.For 10 year models, change suffix "6" to "10".*Based on 4500W/4500W, Non-Simultaneousoperation.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Wattage Limitations for Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Wattage Limitations for Non-Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery▲GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
▲ (GPH based onNon-Simultaneousoperation, whenSimultaneousoperation the GPHwill approximatelydouble.)
Residential Electric 46/47Lowboy Models
■ DOE—Models above20-Gallon Meet orExceed EfficiencyRequirements
■ Fully AutomaticControls
■ Direct Heat Transferwith ImmersedElements
■ Factory-InstalledHydrojet® TotalPerformance System
■ Vitraglas® Lining■ Non-CFC Foam
Insulation■ Water Connections—
3⁄4" NPT■ Factory-Installed Heat
Traps
■ Protective MagnesiumAnode Rod
■ Simultaneous andNon-SimultaneousOperation Available
■ Voltages Available—120V, 208V, 240V,277V, 480V.
■ Single Phase or ThreePhase OperationAvailable—120V &277V
■ T&P Relief Valve■ Design Evaluated by
ETL in Accordancewith Part 280.707(d)of HUD Mobile HomeConstruction andSafety Standards forEnergy Efficiency. Photo of
RE240L6
C
A
D
B
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
—455567
19283847
RE120L6†RE230L6**‡RE240L6**‡RE250L6**‡
247/8297/8325/8325/8
18222426
65129153183
255/8303/4331/2331/2
Lowboy ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS C.E.C. Listed
Recovery90°F Rise*
A
Floor toHeater Top
—0.950.950.95
EnergyFactor
21212121
NatU.S.GPH
18181818
NatImp.GPH
1st Hour**Rating(Gal.)
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
191/8305/8335/8335/8
D
Floor toT&P
Heater
Approx.Shipping
Weight (lbs)
Wattage Limitations for Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Wattage Limitations for Non-Simultaneous Operation
Voltage120V 208V 240V 277V 480V
Recovery▲GPH Temperature Rise ºF
60 80 90 100 120Wattage
yesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
▲ (GPH based onNon-Simultaneousoperation, whenSimultaneousoperation the GPHwill approximatelydouble.)
**Models include supplied insulation blanket (2" thick). Dimensions in charts above do notinclude blanket thickness.For 10 year models, change suffix "6" to "10".
* Based on 4500W/4500W, Non-Simultaneousoperation.All models feature optional top T&P location andmust be specified when ordering.
† Exempt from ASHRAE 90.1b (current standard).Energy Factor and First Hour Rating is based onthe latest AHRI directory listings.
‡ Low watt density element standard on240v/4500w-208v/3500w only.
Residential Electric 48/49Wall Hung Models
■ Fully Automatic Controls■ Direct Heat Transfer With a Single
Immersed Element■ Vitraglas® Lining■ 1" Non-CFC Foam Insulation
■ Factory-Installed Heavy Duty WallMounting Bracket
■ Water Connections—3/4" ■ Protective Magnesium Anode Rod■ Steel Tank
■ Voltages Available—120V, 208V, 240V, 277V, 480V
■ Single Phase Operation Only■ T&P Relief Valve
Photo ofRE16UWV6
TOPVIEW
D
C
WALL
HOTOUTLET
COLDINLET
ELECTRICAL JUNCTION BOX
8"
FRONTVIEW
1213/16"D
HOT OUTLET3/4" CONN.
COLD INLET3/4" CONN.
HEATING ELEMENT & THERMOSTAT ACCESS
A A
E
3/4" RELIEF VALVE OPENING
SIDEVIEW
WALL
BB
BOTTOMVIEW
FRONT
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
61219
RE16WV6†RE112WV6RE120WV6
153/4163/8243/8
141818
375467
145/8185/8185/8
Wall Hung ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Recovery90°F Rise*
A
Height777
NatU.S.GPH
666
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Wall to Front113/4123/4181/4
D
Height to Bracket117/8121/221
E
Floor toT&P Heater
Approx.Shipping
Weight (lbs)
VoltageWattage Limitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
†Maximum wattage at any voltage is 3000W.For 10 year models, change suffix "6" to "10".Single element only.*Based on 1500W operation.
Residential Electric 50/51Utility Models
■ Fully Automatic Controls■ Direct Heat Transfer with a Single
Immersed Element■ Vitraglas® Lining■ 1" Non-CFC Foam Insulation■ Water Connections—3/4" NPT■ Alternate Top Water Connections■ Protective Magnesium Anode Rod■ Voltages Available—120V, 208V, 240V,
277V, 480V.■ Single Phase Operation Only■ T&P Relief Valve■ Design Evaluated by ETL in Accordance
with Part 280.707(d) of HUD MobileHome Construction and SafetyStandards for Energy Efficiency
Photo ofRE112U6
B
C D
F
E
G
A
B
F
F
C
E
D
GA
4" ALTERNATECOLD INLET(PLUGGED)6 &12 GAL.
ONLY
PLUG TYPEANODE6 &12
GAL. ONLY
ALTERNATE HOTOUTLET (PLUGGED)
6 &12 GAL. ONLY
8"
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
10 & 15 Gallon Models
6, 12 & 20 Gallon Models
61012121519
RE16U6†RE110U6RE112U6RE112T6†RE115U6RE120U6
161/2171/2167/8273/4201/4243/4
141618141818
354453485865
101/815
101/4211/8173/4181/4
Utility ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS C.E.C. Listed
Recovery90°F Rise*
A
Floor to Heater Top
777777
NatU.S.*GPH
666666
NatImp*GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor toHot Water
Conn.101/814
101/4211/8163/4181/4
D
Floor toT&P
Conn.31/8
511/16
33
61/83
E
Floor toCold Water
Conn.161/2911/16
161/2273/4101/8101/4
E
Floor toAnode Rod
161/212
167/8273/4
1211/16
243/4
E
Floor toElectricalAccess
Approx.Shipping
Weight (lbs)
VoltageWattage Limitations 120V 208V 240V 277V 480V
RecoveryGPH Temperature Rise ºF
60 80 90 100 120Wattage
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W3500W4000W4500W5000W5500W6000W
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
†Maximum wattage at any voltage is 3000W.For 10 year models, change suffix "6" to "10".Single element only.*Based on 1500W operation.
Residential Electric 52/53Powerful Compact® Model
■ Compact Design■ Fully Automatic Control■ Direct Heat Transfer with Immersed
Element■ Vitraglas® Lining■ Non-CFC Insulation■ Water Connections—3/4" NPT■ Protective Magnesium Anode Rod■ Steel Tank■ Steel Jacket■ T&P Relief Valve OpeningOptional Features:■ Wall Mounting Bracket.■ Aluminum Anode Rod.
Photo ofRE1-2U
B
A
C
2RE1-2U6 121/4 97/8 13135/16
Powerful Compact® ModelDIMENSIONS IN INCHES
ELECTRIC MODELS Meet or exceed ASHRAE 90.1b (current standard) CEC Listed
Recovery90°F Rise*
A
Floor toHeater Top
7
NatU.S.GPH
6
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Water Conn.
Approx.Shipping
Weight (lbs)
Includes a 4ft. cord with 3 prong grounded plug (20 amp circuit required).For 10 year models, change suffix "6" to "10".Single element only.*Based on 1500W operation.Only available as 120V / 1500W.
SMALL FLANGEOF BRACKET
SMALL FLANGEOF BRACKET
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
Optional WallMounting Bracket
(2 brackets)Part Number
265-45018-00
Specialty Products 54/55Electric
FLOWCONTROLLED
TWIN HEATINGMODULE
THERMOSTATICTHREE PHASE
THERMOSTATIC
SINGLEPOINT
InstantaneousWater Heaters
■ On Demand Hot Water – No Delay■ Cut Energy Waste – Flow Switch Activates Heater Only on Demand
(No Stand-by heat loss)■ Continuous Hot Water – No Storage Capacity to Run Out ■ No T&P Relief Valve Needed – Check Local Codes■ Integral Flow Restrictor – Built-In to Ensure Proper Temperature Rise■ 10 Year Warranty on Heater Body/Element Assembly
■ Easy Installation – Mounts on Wall – No Sweat Connections■ Ni Chrome Heating Element – a Unique, Patented Flow Path Ensures
Optimum Heat Transfer and Extended Element Life■ Reduces Calcification■ Space Saving Installation – Compact Size■ Field Serviceable Element – 1 Year Warranty
3.03.53.54.14.15.5
ES-3000-1-S-10ES-3500-1-S-10ES-3500-4-S-10ES-4100-2-S-10ES-4100-5-S-10ES-5500-4-S-10
120120240208277240
41°48°48°56°56°75°
10 AWG10 AWG14 AWG12 AWG14 AWG10 AWG
Single Point Single Phase ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F0.5 GPMVoltage
25.029.014.619.714.822.9
AMPSkW
RatingModel
Number*Recommended
Wire Size
7.59.5
EFT-7500-4-S-10EFT-9500-4-S-10
240240
34°43°
8 AWG8 AWG
Thermostatic Single Phase ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
1.5 GPM
25°32°
Temp.Rise °F
2.0 GPM
51°65°
Temp.Rise °F
1.0 GPM
68°86°
Temp.Rise °F
0.75 GPM
——
Temp.Rise °F
0.5 GPMVoltage
32.040.0
AMPSkW
RatingModel
Number*Recommended
Wire Size
SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials:
Cover: ABS UL rated 94Vo.Glass Reinforced “Fortron®” Heater
Body and Ni Chrome ElementColor: White • Element: Replaceable cartridge insert• Pipe-Fittings: 3/8" compression at top of unit
SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials:
Cover: ABS UL rated 94Vo.Glass Reinforced “Fortron®” HeaterBody and Ni Chrome Element
Color: White • Standard temperature range 100°F-140°F.• Element: Replaceable cartridge insert. • Pipe-Fittings:1/2" compression at bottom of unit.U.L. Listed: E86887(M)
*Additional voltages and wattages are available. For more information, please consult factory.
Electric Instantaneous 56/57Water Heaters (continued)
5.56.57.58.39.5
EFC-5500-4-S-10EFC-6500-4-S-10EFC-7500-4-S-10EFC-8300-2-S-10EFC-9500-4-S-10
240240240208240
25°30°34°38°43°
10 AWG10 AWG8 AWG8 AWG8 AWG
Flow Controlled Single Phase ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
1.5 GPM
18°22°25°29°32°
Temp.Rise °F
2.0 GPM
38°44°51°57°65°
Temp.Rise °F
1.0 GPM
50°59°68°76°86°
Temp.Rise °F
0.75 GPM
75°88°———
Temp.Rise °F
0.5 GPMVoltage
23.027.032.039.040.0
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
19.0EFT-19000-4-D-10 240 43° 10 AWG
Series Two Single Phase Thermostatic ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
3.0 GPM
52°
Temp.Rise °F
2.5 GPM
65°
Temp.Rise °F
2.0 GPM
87°
Temp.Rise °F
1.5 GPMVoltage
2x40 Amps
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
SpecificationsDimensions: 10.75" x 5.25" x 2.875"Weight: 3 lbs.Materials:
Cover: ABS UL rated 94Vo.Glass Reinforced “Fortron®” HeaterBody and Ni Chrome Element
Color: White • Standard temperature range 100°F-140°F.• Element: Replaceable cartridge insert. • Pipe-Fittings:1/2" compression at bottom of unit.
Dimensions: 10" x 9" x 3"Weight: 8 lbs.Materials:
Cover: Enameled Steel.Glass Reinforced “UDEL®” HeaterBody and Ni Chrome Element
Color: White • Element: Dual replaceable cartridgeinserts • Pipe-Fittings: 3/4" NPT at bottom of unit.U.S. Patent No.’s: 4,762,980 and 4,960,976
*Additional voltages and wattages are available. For more information, please consult factory.
18.024.032.0
EFTR-18000-6-T-10EFTR-24000-6-T-10EFTR-32000-6-T-10
480 Y**480 Y**480 Y**
41°54°73°
6 AWG6 AWG8 AWG
Series Three-Three Phase Thermostatic ModelsDIMENSIONS IN INCHES
ELECTRIC
Meet or exceed ASHRecovery Efficiency ranging up to 78% (M-I-75 and
Temp.Rise °F
3.0 GPM
35°47°62°
Temp.Rise °F
3.5 GPM
32°41°55°
Temp.Rise °F
4.0 GPM
25°34°45°
Temp.Rise °F
5.0 GPM
49°65°87°
Temp.Rise °F
2.5 GPM
61°82°—
Temp.Rise °F
2.0 GPM
82°——
Temp.Rise °F
1.5 GPMVoltage
21.7 Amps28.9 Amps38.5 Amps
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
28.038.0
EFT-28000-4-T-10EFT-38000-4-F-10
240240
65°86°
8 AWG Per Module8 AWG Per Module
Series Three-Single Phase Thermostatic ModelsDIMENSIONS IN INCHES
ELECTRIC
Temp.Rise °F
3.0 GPM
47°65°
Temp.Rise °F
4.0 GPM
76°104°
Temp.Rise °F
2.5 GPM
96°130°
Temp.Rise °F
2.0 GPM
——
Temp.Rise °F
1.5 GPMVoltage
3x40 Amps4x40 Amps
CurrentPer
PhasekW
RatingModel
Number*Recommended
Wire Size
SpecificationsSingle Phase Model Dimensions:12.25" x 15.25" x 4.25"Weight: 12 lbs.Three Phase Model Dimensions:12.125" x 20.1875" x 4.125"Weight: 15 lbs.Materials:
Cover: Enameled Steel.Glass Reinforced “UDEL® “ Heater Body and Ni Chrome Element
Color: White • Element: Triple replaceable cartridgeinserts • Pipe-Fittings: 3/4" NPT at bottom of unit.U.S. Patent No.’s: 4,762,980 and 4,960,976
VoltageCode Voltage
Voltage Identification CodeFor All Models
123456
120208220240277480
This unit must have 3 independent electrical circuits using correctly valued wire and 3 circuit breakers.
Example: EFT-28000-4-T-10The 4 in the model numberindicates 240 volt.
*Additional voltages and wattages are available. For more information, please consult factory.**Neutral leg required.
EcoStor2™ 58/59Double-Wall Gas Backup Models
■ Heat Exchanger – Double Wall 11⁄2" O.D. Enamel Coated (Vitraglas®)Steel Coil
■ Self Diagnostic Honeywell Gas Control■ Backup Low NOx Burner■ Sensor Wires for Solar Thermistor
Connections■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining ■ 3/4" NPT Female Connections on
Front for Supply and Return■ 2" Non-CFC Foam Insulation■ Potable Water Connections—
3⁄4" NPT Factory Installed TrueDielectric Fittings
■ Two Protective Anode Rods
■ T&P Relief Valve Included■ Low restriction Brass Drain Valve■ S-DW2-75 Is Not FVIR■ Thermostatic Mixing Valve
(ASSE Approved) Included
A
C
B
G
F
H
E J
D
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
ANODES
KSolar SensorWiringJunction Box
Photo ofS-DW2-504T6FBN
65,00065,00076,000
456075
S-DW2-504T6FBNS-DW2-65T6FBNS-DW2-75S6BN
696982
591/463
623/8
222426
444
113/8113/8143/8
223264306
321/4321/4345/8
50531/252
EcoStor™ Double-Wall Gas Backup ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply101/8101/8121/2
J
Floor toSolar Collector
Return56
591/259
F
Floorto Heater
Top60
631/4623/4
G
Floorto Water
Conn.2628
303/8
K
Depth
Approx.Shipping
Weight (lbs)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
*Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS Input
BTU/Hr.GPH Rec.90°F Rise
S-DW2-504T6FSX 61,000 65S-DW2-6ST6FSX 63,000 67S-DW2-75S6SX 76,000 82
EcoStor2™ TTW® 60/61Power Vent Double-Wall Gas Backup Models
■ Heat Exchanger – Double Wall 11⁄2" O.D.Enamel Coated (Vitraglas®) Steel Coil
■ Self Diagnostic Electronic Honeywell GasControl
■ Backup Low NOx Burner■ Sensor Wires for Solar Thermistor
Connections■ Horizontal and Vertical Venting■ Powerful Blower Motor
- 10 ft. Power Cord—Included (120 VAC)■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining ■ Supply and Return Connections—
3⁄4" NPT■ 2" Non-CFC Foam Insulation
■ Potable Water Connections—3⁄4" NPTFactory Installed True Dielectric Fittings
■ Two Protective Anode Rods■ T&P Relief Valve Included■ Low restriction Brass Drain Valve■ S-DW2-TW-75 Is Not FVIR Compliant■ Thermostatic Mixing Valve (ASSE
Approved) Included
A
C
B
G
F
H
E J
D
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
KSolar SensorWiringJunction Box
Photo ofS-DW2-TW-65T6FBN
67,00070,00076,000
456070
S-DW2-TW-50T6FBNS-DW2-TW-65T6FBNS-DW2-TW-75T6BN
727582
591/463
623/8
222426
3 or 43 or 4
4
113/8113/8143/8
247281336
321/4321/4345/8
50531/252
EcoStor2™ TTW® Power Vent Double-Wall Gas Backup ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply101/8101/8121/2
J
Floor toSolar Collector
Return56
591/259
F
Floorto Heater
Top60
631/4623/4
G
Floorto Water
Conn.2628
303/8
K
Depth
Approx.Shipping
Weight (lbs)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Subtract 5ft. for eachadditional 90° elbow.**S-DW2-TW-75 Max. 3" ventlength is 50ft.
3"Vent Pipe
4"Vent PipeS-DW2-TW-75T6FBN
S-DW2-TW-65T6FBNS-DW2-TW-50T6FBN
60 ft.**7 ft.55 ft.50 ft.45 ft.
180 ft.15 ft.
175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
*Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS Input
BTU/Hr.GPH Rec.90°F Rise
S-DW2-TW-50T6FSX 60,000 65S-DW2-TW-65T6FSX 63,000 68S-DW2-TW-75T6SX 75,500 81
EcoStor™ Open Loop 62/63Gas Backup Models
■ Heat exchanger – Doublewall 11⁄2" O.D. Enamel Coated(Vitraglas®) Steel Coil
■ Self Diagnostic ElectronicHoneywell Gas Control
■ Backup Low NOx Burner■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining ■ Supply and return
Connections—3⁄4" NPT■ 2" Non-CFC Foam Insulation■ Potable Water Connections—
3⁄4" NPT (65 gallon), 1" NPT(75 gallon) and 11⁄4" NPT (100gallon) Factory-Installed TrueDielectric Fittings
■ Protective anode Rods—65 and 75 gallon Models(1 Anode Rod), 100 gallonModel (2 Anode Rods)
■ T&P Relief Valve Included■ Low Restriction Brass
Drain Valve■ S-2-75S6BN and
S-2-100T6BN are Not FVIRCompliant
■ Thermostatic Mixing Valve(ASSE Approved) Included
Photo ofS-2-65T6FBN65 /75 Gallon Capacity 100 Gallon Capacity
K
H
K
A A
G G
F F
E EJ J
D D
H
B B
CC
Solar Thermistor Wiresand Gas Control SensorUnder Cover
AnodeAnodes
Hot WaterOutletCold WaterInlet
Hot WaterOutletCold WaterInletSolar Sensor
WiringJunction Box
Solar SensorWiringJunction Box
FromSolarCollector
Solar ThermistorWires and GasControl SensorUnder Cover
SolarThermistorWiresUnder Cover
SolarThermistorWiresUnder Cover
To SolarCollector
To SolarCollector
From SolarCollector
AnodeAnodes
Hot WaterOutletCold WaterInlet
Hot WaterOutletCold WaterInletSolar Sensor
WiringJunction Box
Solar SensorWiringJunction Box
65,00076,00085,000
6575100
S-2-65T6FBNS-2-75S6BNS-2-100T6BN
698292
63623/8
6311/16
2426
281/4
444
113/8141/8141/4
215250400
601/4593/4383/4
531/252
391/4
EcoStar™ Open Loop Gas Backup ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply101/8121/2171/2
J
Floor toSolar Collector
Return591/259
651/2
F
Floorto Heater
Top601/4593/4671/2
G
Floorto Water
Conn.28
303/8321/4
K
Depth
Approx.Shipping
Weight (lbs)
*Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”. LP GAS MODELS Input
BTU/Hr.GPH Rec.90°F Rise
S-2-65T6FSX 63,000 67S-2-75S6SX 76,000 82S-2-100T6SX 88,500 95
EcoStor™ TTW® Power Vent 64/65Open Loop Gas Backup Models
■ 3/4" NPT Solar Collector Supply andReturn Connections (No Internal HeatExchanger)
■ Self Diagnostic Electronic HoneywellGas Control
■ Backup Low NOx Burner■ Sensor Wires for Solar Thermistor
Connections■ Horizontal and Vertical Venting■ Powerful Blower Motor
- 10 ft. Power Cord—Included (120 VAC)
■ Factory-Installed Hydrojet® TotalPerformance System
■ Vitraglas® Lining ■ Supply and Return Connections—
3⁄4" NPT■ 2" Non-CFC Foam Insulation
■ Potable Water Connections—3⁄4" NPT Factory-Installed TrueDielectric Fittings
■ Two Protective Anode Rods■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve■ S-2-TW75T6BN Is Not FVIR Compliant■ Thermostatic Mixing Valve (ASSE
Approved) Included
B
A
G
F
H
E J
D
B
SolarThermistorWiresand GasControl SensorUnder Cover
From SolarCollector
SolarThermistorWiresUnder Cover
To SolarCollectorK
Anode Hot WaterOutletCold WaterInlet
From SolarCollector
SolarSensorWiringJunctionBox
Photo ofS-2-TW65T6FBN
70,00076,000
6575
S-2-TW65T6FBNS-2-TW75T6BN
7582
63623/8
2426
33
113/8141/8
225260
321/4345/8
531/252
EcoStor™ TTW® Power Vent Open Vent Gas Backup ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply101/8121/2
J
Floor toSolar Collector
Return591/259
F
Floorto Heater
Top601/4593/4
G
Floorto Water
Conn.28
303/8
K
Depth
Approx.Shipping
Weight (lbs)
*Based on manufacturer’s rated recovery efficiency. Propane models feature a Titanium Stainless Steel propane burner. For propane (LP) models change suffix “BN” to “SX”.120 V.A.C. required for power venting.120 V.A.C. 60HZ 3.1 Amperes.
Subtract 5ft. for eachadditional 90° elbow.** S-2-TW-75 Max. 3" ventlength is 50 ft. (15.24 m).
3"Vent Pipe
4"Vent PipeS-2-TW75T6BN
S-2-TW65T6FBN
60 ft.**7 ft.55 ft.50 ft.45 ft.
180 ft.15 ft.
175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
LP GAS MODELS InputBTU/Hr.
GPH Rec.90°F Rise
S-2-TW65T6FSX 63,000 68S-2-TW75T6SX 75,500 81
EcoStor2™ SC Ultra Low NOx 66/67Double-Wall Gas Backup Models
■ Heat Exchanger – Double Wall 11⁄2" O.D.Enamel Coated (Vitraglas®) Steel Coil
■ Self Diagnostic Honeywell Gas Control■ Eco-Defender Safety System®
■ Backup Ultra Low NOx Burner■ Sensor Wires for Solar Thermistor
Connections■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining ■ Supply and Return Connections—3⁄4"
NPT■ 2" Non-CFC Foam Insulation■ Potable Water Connections—3⁄4" NPT
Factory Installed True Dielectric Fittings■ Two Protective Anode Rods
■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve■ Complies with the Latest Ultra-Low
NOx Requirements (10/ngts NOx limit)■ Thermostatic Mixing Valve (ASSE
Approved) Included
A
B
G
F
H
E J
D
SolarThermistorWires,Gas ControlSensor
SolarThermistorWires
C
ANODES
KSolar SensorWiringJunction Box
Photo ofS-DW4-U5036FRN
40,00055,000
4560
S-DW4-U5036FRNS-DW2-U65T6FRN
4357
591/463
2224
3 4
115/8115/8
233272
321/4321/4
50531/2
EcoStor2™ Ultra Low NOx Double-Wall Gas Backup ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
80% Recovery Efficiency
A
Floorto FlueConn.
B
JacketDia.
GPHRecovery
90°F Rise*Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentSize
D
Floorto T&PConn.
E
Floorto GasConn.
H
Floor toSolar Collector
Supply101/8101/8
J
Floor toSolar Collector
Return561/4591/2
F
Floorto Heater
Top60
631/4
G
Floorto Water
Conn.2628
K
Depth
Approx.Shipping
Weight (lbs)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
*Based on manufacturer’s rated recovery efficiency.Complies with the latest ultra-low NOx requirement (10 ng/J NOx limit).
EcoStor™ 68/69Dual Coil Heat Exchanger Backup Models
■ Dual Coil Design—A single wall heatexchanger is located in the upperportion of the tank. A double wallheat exchanger is located in thelower portion ofthe tank
■ Applications—Dual heat exchangerslocated inside the tank may beconnected to a variety of differentheating systems
■ Sensor Wires for Solar ThermistorConnections
■ Factory-Installed Hydrojet® TotalPerformance System
■ Vitraglas® Lining ■ Supply and Return Connections—1"
NPT Upper Coil, 3⁄4" NPT Lower Coil ■ 2" Non-CFC Foam Insulation
■ Potable Water Connections—3⁄4"NPT Factory-Installed True DielectricFittings Extend Water Heater Lifeand Eases Installation
■ Two Protective Anode Rods■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve■ Thermostatic Mixing Valve (ASSE
Approved) Included
CD
H
GF
E
A
SolarThermistorWiresandThermostat
SolarThermistorWiresandThermostat
Photo ofS-DC-DW2-55R6SW
B Solar Sensor Wiring Junction Box
Electric WiringJunction Box
5570110
S-DC-DW2-55R6SWS-DC-DW2-70R6SWS-DC-DW2-110R6SW
591/4591/4621/2
2224
281/4
623/4623/466
5353
553/4
282313442
EcoStor™ Dual Coil Heat Exchanger Backup ModelsDIMENSIONS IN INCHES
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
371/2371/2391/4
F
Floor toUpper Coll.
Return5656
573/4
E
Floor toUpper Coll.
Supply53/853/853/8
H
Floor toLower Coll.
Return271/2271/2271/2
G
Floor toLower Coll.
Supply
Approx.Shipping
Weight (lbs)
0.00
2.00
4.00
6.00
8.00
10.00
12.00
0.00
5.00
10.00
15.00
20.00
25.00
Single-wall (Upper Coil)
Double-wall (Lower Coil)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SI)
Hea
d Lo
ss (f
t. w
.c.)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
EcoStor™ SC 70/71Single-Wall Electric Backup Models
■ Heat Exchanger – Single Wall 11⁄2"O.D. Enamel Coated (Vitraglas®) Steel Coil
■ Supplied Sensor Wires for SolarThermistor Connections
■ Integrated Mixing Device■ Element Backup – Single or Dual
4500W Heating Elements■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining ■ 1" NPT Female Connections on Front
for Supply and Return■ Potable Water Connections – 3/4" NPT
Factory-Installed True DielectricFittings
■ 2" Non-CFC Foam Insulation
■ Two Protective Anode Rods■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve■ Thermostatic Mixing Valve
(ASSE Approved) Included
CD
F
E
A
& S SW2 75R)
Solar ThermistorWires UpperHeating Elementwith Thermostat
Thermostat(controlslower element)
Solar ThermistorWires LowerHeating Element
Photo ofS-SW2-60R6DS
B
Solar SensorWiringJunction Box
Optional Outletfor Recirculation(S-SW2-60R& S-SW2-75R)
6075115
S-SW2-60R6DSS-SW2-75R6DSS-SW2-115R6DS
591/4591/4623/4
2224
281/4
631/4631/4663/4
5353
553/4
210236340
EcoStor™ Single-Wall Electric Backup ModelsDIMENSIONS IN INCHES
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
291/2291/2291/2
E
Floor toSolar Coll.
Supply73/873/873/8
F
Floor toSolar Coll.
Return
Approx.Shipping
Weight (lbs)
ModelNumber Single
ElementDual
Element
Electric Backup Water Heating Ratings
First Hour Supply (Gal.) StandbyHeat Loss
Rating(°F/Hr.)
S-SW2-60R6DSS-SW2-75R6DSS-SW2-115R6DS
465383
8497124
1.10.90.7
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
For single element models change “D” to “S”.(Ex. S-SW2-60R6SS)
EcoStor2™ 72/73Double-Wall Electric Backup Models
■ Heat Exchanger—Double wall 11⁄2" O.D. Enamel Coated (Vitraglas®)Steel Coil
■ Supplied Sensor Wires for SolarThermistor Connections
■ Element Backup—Single or Dual4500W Heating Elements—Optional5500W
■ Factory-Installed Hydrojet® TotalPerformance System
■ Vitraglas® Lining ■ 3/4" NPT Female Connections on
Front for Supply and Return■ Potable Water Connections—
3/4" NPT Factory Installed TrueDielectric Fittings
■ 2" Non-CFC Foam Insulation
■ Two Protective Anode Rods■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve■ Thermostatic Mixing Valve (ASSE
Approved) Included
CD
F
E
A
)
Solar ThermistorWires UpperHeating Elementwith Thermostat
Thermostat(controlslower elementon dualelement models)
Solar ThermistorWires LowerHeating Element(on dualelement models)
Photo ofS-DW2-60R6DS
Solar SensorWiringJunction Box
Optional Outletfor Recirculation(S-DW2-60R& S-DW2-75R)
B
6075115
S-DW2-60R6DSS-DW2-75R6DSS-DW2-115R6DS
591/4591/4623/4
2224
281/4
631/4631/4663/4
5353
553/4
217241345
EcoStor2™ Double-Wall Electric Backup ModelsDIMENSIONS IN INCHES
SOLAR MODELS C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
291/2291/2291/2
E
Floor toSolar Coll.
Supply73/873/873/8
F
Floor toSolar Coll.
Return
Approx.Shipping
Weight (lbs)
ModelNumber Single
ElementDual
Element
Electric Backup Water Heating Ratings
First Hour Supply (Gal.) StandbyHeat Loss
Rating(°F/Hr.)
S-DW2-60R6DSS-DW2-75R6DSS-DW2-115R6DS
465383
8497124
1.10.90.7
For single element models change “D” to “S”.(Ex. S-DW2-60R6SS)
Heat Exchanger Pressure Drop Curve
Flow Rate (GPM)
Pres
sure
Dro
p (P
SID
)
Hea
d Lo
ss (f
t. w
.c.)
16.00
14.00
12.00
10.00
8.00
6.00
4.00
2.00
0.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.000 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Solar Saver® Electric 74/75Backup Models
■ Vitraglas® Lining■ Factory-Installed Hydrojet® Total
Performance System■ Equipped with a 4500 watt Element And
Automatic Thermostat – Where a BackupSystem is Desired. If Storage Only IsDesired Do Not Connect the Unit to theElectrical Service.
■ Top of Tank Access for Wiring and Water Connections
■ Pre-Wired Sensor Lead■ Thermal Feet■ Water Connections—3/4" NPT Factory
Installed True Dielectric Fittings ■ 2" Non-CFC foam insulation■ Protective Magnesium Anode Rod■ Consult Factory for Other Wattages■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve
B
A
C
ED
F
4
1
3
2
8"8"
#1 - 3/4" Pump Suction#2 - 3/4" Cold Inlet#3 - 3/4" Collector Return#4 - 3/4" Hot Outlet
Photo of MS80R6SS
6580119
MS65R6SSMS80R6SS†MS120R6SS†
5959
621/2
222428
6060
631/2
521/2521/256
168210310
Solar Saver® Electric Backup ModelsDIMENSIONS IN INCHES
SOLAR MODELS
Meet or exceed ASHRAE 90.1b (current standard)
C
Floor to Water Conn.
B
JacketDia.
A
Floor to Heater Top
Gal.Cap.
ModelNumber
D
Floor toT&P Conn.
—38
381/4
E
Fl. to Alt.Coll. Return
Conn.—77/877/8
F
Fl. to Alt.Coll. Supply
Conn.
Approx.Shipping
Weight (lbs)
NOTE: Suffix letter “S” denotes single element and surface mounted thermostat.If requirements are for storage only, do not use element connections.Second suffix letter “S” denotes Screw-Type Element. Meets California Energy Commission requirements.†Models offer additional pump suction and collector return connections.
Residential Gas Combi1™ 76/77Single-Wall Atmospheric Models
Photo ofC-SW2-504T10FBN
C
AJ
H
E
F
D & G
The Combi1™ FVIR DefenderSafety System® Models Feature(50 gallon model only):■ Advanced ScreenLok®
Technology Flame ArrestorDesign
■ Flammable Vapor SensorAll Combi1™ Models Feature:■ Bradford White ICON
System™
■ Heat Exchanger—SingleWall 11⁄2" O.D. Enamel Coated(Vitraglas®) Steel Coil
■ Provides Domestic HotWater and Space Heating inOne System
■ Low Heat Exchanger Head Loss—Up to 10 GPM Flow, withLess than 0.80 ft. of Head Loss
■ Vitraglas® Lining■ Factory-Installed Hydrojet®
Total Performance System■ Water Connections – 3/4"
NPT Factory-Installed TrueDielectric Fittings
■ 1" Front NPT Supply andReturn Connections
■ 2" Non-CFC Foam Insulation■ Two Protective Anode Rods■ T&P Relief Valve Installed■ Low Restriction Brass Drain
Valve■ Thermostatic Mixing Valve
(ASSE Approved) Included
K
B
PLUG TYPEANODE
65,00076,000
4572
C-SW2-504T10FBNC-SW2-75T10BN
591/4
621/4
2226
50513/4
236326
Combi1™ Atmospheric Vent ModelDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b(current standard) C.E.C. Listed
80% Thermal Efficiency
A
Floor toFlue
Conn.13
137/8
E
Floor toGas
Conn.311/2295/8
F
Floor toExchanger
Inlet563/859
H
Floor toTop ofHeater
603/863
J
Floor toTop Water
Conn.241/2303/8
K
Depth50
513/4
G
Floor toExchanger
Outlet
B
JacketDia.
InputBTU/Hr.
7081
GPHRecovery
90°F Rise*Gal.Cap.
ModelNumber
D
Floor toT&P
Conn.44
C
VentSize
Approx.Shipping
Weight (lbs)
Heat Exchanger Head Loss
GPMFeet of Head Loss
20.03
50.20
80.51
100.80
121.15
All propane models feature a Titanium Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.*Based on manufacturer’s rated recovery efficiency.CAEF is .55 and CAAFLUE % is 80.0.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output
140°F120°F20°F
4.1 GPM35,500 BTU/Hr.
120°F100°F20°F
4.6 GPM39,500 BTU/Hr.
100°F80°F20°F
4.6 GPM39,500 BTU/Hr.
120°F100°F20°F
5.6 GPM47,500 BTU/Hr.
100°F80°F20°F
5.6 GPM47,500 BTU/Hr.
C-SW2-504TC-SW2-75T C-SW2-504T C-SW2-75T
*These values were obtained using 180°F stored tank temperature.Net Output is the space heating capacity based on normal piping and pickupallowance of 15%.Actual values may vary based on circulator flow rate, number of zones, waterand space heating demands. Numbers subject to change.
LP GAS MODELS InputBTU/Hr.
GPH Rec.90°F Rise
C-SW2-504T10FSX 61,000 66C-SW2-75T10SX 76,000 81
Residential Gas Combi1™ TTW® 78/79Single-Wall Power Vent Models
The Combi1™ TTW® FVIR Defender SafetySystem® Models Feature (50 gallon modelonly):■ Advanced ScreenLok® Technology
Flame Arrestor Design■ Flammable Vapor SensorAll Combi1™ TTW® Models Feature:■ Bradford White ICON System™
■ Heat Exchanger—Single Wall 11⁄2"O.D. Enamel Coated (Vitraglas®) Steel
■ Provides Domestic Hot Water andSpace Heating in One System
■ Low Heat Exchanger Head Loss—Up to 10 GPM Flow, with Less than0.80 ft. of Head Loss
■ Vitraglas® Lining■ Power Vented
- 10 ft. Power Cord Included (120 VAC)
■ Factory-Installed Hydrojet® TotalPerformance System
■ Horizontal and Vertical Venting■ Water Connections –
3/4" NPT Factory-InstalledTrue Dielectric Fittings
■ 1" NPT Front Supply andReturn Connections
■ 2" Non-CFC Foam Insulation■ Two Protective Anode Rods■ T&P Relief Valve Installed■ Low Restriction Brass
Drain Valve■ Pedestal Base■ Thermostatic Mixing Valve
(ASSE Approved) IncludedPhoto of
C-SW2-TW50T10FBN
C
A
J
H
E
F
D & GK B
67,00076,000
4572
C-SW2-TW50T10FBNC-SW2-TW75T10BN
657/8
683/8
2226
501/8
53243313
Combi1™ TTW® Single-Wall Power Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b(current standard) C.E.C. Listed
80% Recovery Efficiency
A
Floor toVent
Conn.113/4
15
E
Floor toGas
Conn.311/2
341/2
F
Floor toExchanger
Inlet563/8
601/4
H
Floor toTop ofHeater
603/4
641/4
J
Floor toTop Water
Conn.263/4
31
K
Depth50
53
G
Floor toExchanger
Outlet
B
JacketDia.
InputBTU/Hr.
Gal.Cap.
7282
GPHRecovery
90°F Rise*Model
Number
D
Floor toT&P
Conn.3 or 43 or 4
C
VentSize
Approx.Shipping
Weight (lbs)
All propane models feature a Titanium Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.*Based on manufacturer’s rated recovery efficiency.120 V.A.C Required for Power Venting / 120 V.A.C., 60HZ, 3.1 Amperes.
Heat ExchangerHead Loss
GPM
2581012
Ft. ofHd. Loss
0.030.200.510.801.15
3"Vent Pipe
4"Vent Pipe
C-SW2-TW50C-SW2-TW75
60 ft.** 7 ft.55 ft.50 ft.45 ft.
180 ft. 15 ft.175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
Subtract 5ft. for each additional 90° elbow.**C-SW2-TW75 maximum 3" vent length is 50ft.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow Rate (TW50)Net Output (TW50)Flow Rate (TW75)Net Output (TW75)
140°F120°F20°F
4.1 GPM35,000 BTU/Hr.
4.1 GPM35,000 BTU/Hr.
120°F100°F20°F
4.6 GPM39,500 BTU/Hr.
5.6 GPM47,500 BTU/Hr.
100°F80°F20°F
4.6 GPM39,500 BTU/Hr.
5.6 GPM47,500 BTU/Hr.
*These values were obtained using 180°F stored tank temperature.Net Output is the space heating capacity based on normal piping and pickupallowance of 15%.Actual values may vary based on circulator flow rate, number of zones, waterand space heating demands. Numbers subject to change.
LP GAS MODELS InputBTU/Hr.
GPH Rec.90°F Rise
C-SW2-TW50T10FSX 60,000 65C-SW2-TW75T10SX 75,500 81
Residential Gas Combi2™ 80/81Double-Wall Atmospheric Models
Photo ofC-DW2-504T10FBN
C
AJ
H
E
F
D & G
The Combi2™ FVIR Defender Safety System®
Models Feature (50 gallon model only):■ Advanced ScreenLok® Technology Flame
Arrestor Design■ Flammable Vapor SensorAll Combi2™ Models Feature:■ Bradford White ICON System™
■ Heat Exchanger—Double Wall 11⁄2" O.D.Enamel Coated (Vitraglas®) Steel CoilEnsures Separation of Potable Water andHeating Fluid
■ Provides Domestic Hot Water and SpaceHeating in One System
■ Low Heat Exchanger Head Loss—Up to10 GPM Flow, with Less than 3.75 ft. ofHead Loss
■ Vitraglas® Lining■ Factory-Installed Hydrojet® Total
Performance System
■ Water Connections – 3/4" NPT Factory-Installed True Dielectric Fittings
■ 3/4" Front NPT Supply and ReturnConnections
■ 2" Non-CFC Foam Insulation■ Two Protective Anode Rods■ T&P Relief Valve Installed■ Low Restriction Brass Drain Valve■ Thermostatic Mixing Valve
(ASSE Approved) Included
K
B
65,00076,000
4572
C-DW2-504T10FBNC-DW2-75T10BN
59 1/4
621/4
2226
50513/4
238302
Combi2™ Double-Wall Atmospheric ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b(current standard) C.E.C. Listed
80% Thermal Efficiency
A
Floor toFlue
Conn.13
137/8
E
Floor toGas
Conn.27 7/8
295/8
F
Floor toExchanger
Inlet56 3/859
H
Floor toTop ofHeater
60 3/863
J
Floor toTop Water
Conn.241/2303/8
K
Depth50
513/4
G
Floor toExchanger
Outlet
B
JacketDia.
InputBTU/Hr.
7081
GPHRecovery
90°F Rise*Gal.Cap.
ModelNumber
D
Floor toT&P
Conn.44
C
VentSize
Approx.Shipping
Weight (lbs)
Heat Exchanger Head Loss
GPMFeet of Head Loss
20.15
50.94
82.40
103.75
125.40
All propane models feature a Titanium Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.*Based on manufacturer’s rated recovery efficiency.CAEF is .55 and CAAFLUE % is 80.0.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output
140°F120°F20°F
2.3 GPM20,000 BTU/Hr.
120°F100°F20°F
3.4 GPM29,000 BTU/Hr.
100°F80°F20°F
4.4 GPM38,000 BTU/Hr.
*These values were obtained using 180°F stored tank temperature.Net Output is the space heating capacity based on normal piping and pickupallowance of 15%.Actual values may vary based on circulator flow rate, number of zones, waterand space heating demands. Numbers subject to change.
LP GAS MODELS InputBTU/Hr.
GPH Rec.90°F Rise
C-DW2-504T10FSX 61,000 66C-DW2-75T10SX 76,000 81
Residential Gas Combi2™ TTW® 82/83Double-Wall Power Vent Models
The Combi2™ TTW® FVIR DefenderSafety System® Models Feature(50 gallon model only):■ Advanced ScreenLok® Technology Flame
Arrestor Design■ Flammable Vapor SensorAll Combi2™ TTW® Models Feature:■ Bradford White ICON System™
■ Heat Exchanger—Double Wall 11⁄2" O.D.Enamel Coated (Vitraglas®) Steel CoilEnsures Separation of Potable Water andHeating Fluid
■ Provides Domestic Hot Water and HydronicHeating in One System
■ Low Heat Exchanger Head Loss—Up to 10GPM Flow, with Less than 3.75 ft. of Head Loss
■ Vitraglas® Lining■ Factory-Installed Hydrojet®
Total Performance System
■ Power Vented- 10 ft. Power Cord Included (120 VAC)
■ Horizontal and Vertical Venting■ Water Connections—3/4" NPT
Factory-Installed True Dielectric Fittings ■ 3/4" Front Supply and Return Connections■ 2" Non-CFC Foam Insulation■ Two protective Anode Rods■ T&P Relief Valve Installed■ Low Restriction Brass Drain Valve■ Pedestal Base■ Thermostatic Mixing Valve (ASSE Approved) Included
Photo ofC-DW2-TW50T10FBN
C
A
J
H
E
F
D & G
K B
67,00076,000
4572
C-DW2-TW50T10FBNC-DW2-TW75T10BN
657/8
683/82226
501/8
53245315
Combi2™ TTW® Double-Wall Power Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b(current standard) C.E.C. Listed
Recovery Efficiency ranging up to 80% (Minimum)
A
Floor toVent
Conn.113/4
15
E
Floor toGas
Conn.28
307/8
F
Floor toExchanger
Inlet563/8
601/4
H
Floor toTop ofHeater
603/4
641/4
J
Floor toTop Water
Conn.263/4
31
K
Depth501/8
53
G
Floor toExchanger
Outlet
B
JacketDia.
InputBTU/Hr.
Gal.Cap.
7282
GPHRecovery
90°F Rise*Model
Number
D
Floor toT&P
Conn.3 or 43 or 4
C
VentSize
Approx.Shipping
Weight (lbs)
All propane models feature a Titanium Stainless Steel burner. For propane (LP) models change suffix “BN” to “SX”.*Based on manufacturer’s rated recovery efficiency.120 V.A.C Required for Power Venting / 120 V.A.C., 60HZ, 3.1 Amperes.
Heat ExchangerHead Loss
GPM
2581012
Ft. ofHd. Loss
0.150.942.403.755.40
3"Vent Pipe
4"Vent Pipe
C-DW2-TW50C-DW2-TW75
60 ft.** 7 ft.55 ft.50 ft.45 ft.
180 ft. 15 ft.175 ft.170 ft.165 ft.
Max. Equivalent LengthMin. Equivalent LengthNumber 1of 290° Elbows 3
Subtract 5ft. for each additional 90° elbow.**C-DW2-TW75 maximum 3" vent length is 50ft.
Heat Exchanger Values*
Supply TemperatureReturn TemperatureDifferentialFlow RateNet Output
140°F120°F20°F
2.3 GPM20,000 BTU/Hr.
120°F100°F20°F
3.4 GPM29,000 BTU/Hr.
100°F80°F20°F
4.4 GPM38,000 BTU/Hr.
*These values were obtained using 180°F stored tank temperature.Net Output is the space heating capacity based on normal piping and pickupallowance of 15%.Actual values may vary based on circulator flow rate, number of zones, waterand space heating demands. Numbers subject to change.
LP GAS MODELS InputBTU/Hr.
GPH Rec.90°F Rise
C-DW2-TW50T10FSX 60,000 65C-DW2-TW75T10SX 75,500 81
Residential PowerStor Series® 84/85Single-Wall Indirect Models
■ Heat Exchanger - SingleWall 11⁄2" O.D. EnamelCoated (Vitraglas®) SteelCoil
■ Vitraglas® Lining■ Factory-Installed
Hydrojet® TotalPerformance System
■ Water Connections – 3/4"NPT Factory-InstalledTrue Dielectric Fittings(SW-2-120Lhas 1" NPT WaterConnection)
■ 1" NPT Connection forBoiler Supply And Return
■ 2" Non-CFC FoamInsulation
■ Immersion Type Aquastat– Accurate TemperatureControl
■ Three ProtectiveAluminum Anode Rods
■ T&P Relief Valve Included■ Low Restriction Brass
Drain Valve■ Limited Lifetime Tank and
Heat Exchanger Warranty■ AHRI Certified■ Standby Heat Loss Is
Less than 1/2°F per Hour(ASHRAE 90.1b CurrentStandard)
Photo ofSW-2-65-L
DA F
EG
C
B
DA
F
EG
C
B
POTABLECONNECTIONS
ANODE RODS(TYPICAL)
(TYPICAL)
CON
SW-2-30-L
SW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
3038486075116
SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
2222222224
281/4
335/8411/8461/4591/459
621/2
281/4343/8401/8531/8527/8553/4
343/8417/84760
593/4631/4
164185195225250370
271/2271/2271/2271/2271/2281/2
PowerStor Series® Single-Wall Indirect ModelsDIMENSIONS IN INCHES
C
Floor toT&P
Conn.
A
Floor toHeater
Top
B
JacketDia.
GallonCapacity
ModelNumber
D
Floor toWaterConn.
53/853/853/853/853/863/8
E
Floor toExchanger
Outlet
F
Floor toExchanger
Inlet111/2111/2111/2111/2111/2111/2
G
Floor to Aquastat
Approx.Shipping
Weight (lbs)
ModelNumber 140°F 115°F
DOE Water Heater Performance
SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
Maximum FirstHour Rating
(Gal.) @
279288297306321357
429438447456470507
140°F 115°F4.24.24.24.24.24.2
6.76.76.76.76.76.7
ContinuousDraw Rating
(Gal./Min.) @
ApproximateBoiler OutputNeeded for
Ratings (BTU/Hr.)220,000220,000220,000220,000220,000220,000
ModelNumber
AHRI Water Heater Ratings
SW-2-30-LSW-2-40R-LSW-2-50R-LSW-2-65-LSW-2-80-LSW-2-120-L
First HourDelivery
255260265275295325
ContinuousDraw Rating
@ 135°F(Gal./Hr.)
235235235235235235
StandbyHeat Loss
Rating(°F/Hr.)
1.21.10.90.70.60.4
HeatSource
Flow Rate(Gal./Min.)
13.713.713.713.713.713.7
HeatReq.Rate
(BTU/Hr.)157,000157,000157,000157,000157,000157,000
Note: These certified ratings were obtained with a heat source output rate and flowrate as specified and a 180° F boiler water supply temperature. Other results will beobtained under different conditions.
Note: Based on 200° F boiler water temperature and 50°F potable water inlettemperature.
Residential PowerStor2™ Series® 86/87Double-Wall Indirect Models
■ Heat Exchanger—Double Wall 11⁄2" O.D.Enamel Coated (Vitraglas®) Steel Coil
■ Head Loss—Less than 5 ft. ofHead Loss with Flows up to 10 GPM
■ Vitraglas® Lining■ Factory-Installed Hydrojet®
Total Performance System■ Water Connections—3/4" NPT Factory-
Installed True Dielectric Fittings■ 2" Non-CFC Foam Insulation■ Surface-Mount Thermostat■ Two Protective Magnesium Anode Rods■ T&P Relief Valve Installed■ Low Restriction Brass Drain Valve■ Limited Lifetime Warranty on Tank
and Heat Exchanger■ AHRI Certified■ Standard Heat Loss—Less than 1/2°F per
Hour (ASHRAE 90.1b Current Standard) Photo ofDW-2-50-L
D A
F
E
C
G
TEMPERATUREANDPRESSURERELIEF VALVE
FROM BOILERSUPPLY3/4" NPT
TO BOILERRETURN3/4" NPT
DRAIN COUPLING3/4" NPT
SURFACEMOUNTEDTHERMOSTAT
B
POTABLE WATER FITTINGS - 3/4" NPTANODES
COLDWATERINLET
HOTWATERINLET
41461/45959
38486475
DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L
22222224
343/8401/8531/8527/8
417/8471/460
593/4
53/853/853/853/8
111/2111/2111/2111/2
195205235255
PowerStor2™ Series® Double-Wall Indirect ModelsDIMENSIONS IN INCHES
D
Floor to WaterConn.
E
Floor toBoilerReturn
271/2271/2271/2271/2
F
Floor toBoilerSupply
C
Floor to T&P
Conn.
B
JacketDia.
A
Floor to Heater
TopGallon
Capacity
ModelNumber
G
Floor toThermostat
Approx.Shipping
Weight (lbs)
ModelNumber
AHRI Water Heater Ratings
DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L
First HourDelivery
123133148158
ContinuousDraw Rating
@ 135°F(Gal./Hr.)
98989898
StandbyHeat Loss
Rating(°F/Hr.)
1.10.90.70.6
MinimumHeat Req.
Rate(BTU/Hr.)
65,00065,00065,00065,000
MinimumHeat SourceFlow Rate(Gal./Min.)
8.08.08.08.0
ModelNumber
DOE Water Heater Performance
DW-2-40-LDW-2-50-LDW-2-65-LDW-2-80-L
140°F 115°F
Maximum FirstHour Rating
(Gal.) @
808796106
122129138148
140°F 115°F
ContinuousDraw Rating
(Gal./Min.) @
Approximate BoilerOutput Needed
For Ratings(BTU/Hr.)
0.90.90.90.9
1.61.61.61.6
55,00055,00055,00055,000
Note: These certified ratings were obtained with a heat source output rate and flowrate as specified and a 180° F boiler water supply temperature. Other results will beobtained under different conditions.
Note: Based on 200° F boiler water temperature and 50°F potable water inlettemperature.
Residential PowerStor Series® 88/89SS Stainless Steel Single-Wall Indirect Models
■ Stainless Steel Heat Exchanger—Single-Wall 1"O.D. Stainless Steel Coil.
■ Stainless Steel Tank and Heat Exchanger—Madefrom Chromium Molybdenum - Titanium Ferritic444 Stainless Steel Alloy.
■ Immersed Adjustable Honeywell Aquastat—FastActing Immersion Aquastat for AutomaticTemperature Control
■ Supply and Return Connections—3⁄4" NPTFemale Connections Are Located on the Front for Both the Boiler Supply and Boiler Return (1" NPT on RTV-119)
■ 2" Non-CFC Foam Insulation■ Potable Water Connections—3/4" NPT Factory-
Installed Dielectric Fittings Extend Water HeaterLife and Eases Installation (11⁄4" NPT on RTV-119)
■ T&P Relief Valve Included■ Steel Jacket■ Low Restriction Brass Drain Valve■ AHRI Certified
Photo of RTV-40-L
EF
H
CD A
G
OUTLET
T&P
B
E L
K H
C
F
G
D
A
B
RTV-40-LRTV-52-LRTV-75-L
RTV-120-L*Floor to Top Spare 3/4" NPT
Tank Connection is 413⁄4"Floor to Bottom Spare 3/4" NPT
Tank Connection is 17"
1 2 1
2
242424
301/4
351/4455/8637/8605/8
RTV-40-LRTV-52-LRTV-75-LRTV-120-L
555
111/4
91/291/291/2177/8
245/8283/8281/4451/2
————
————
8393117315
PowerStor Series® SS Stainless Steel Single-Wall Indirect ModelsDIMENSIONS IN INCHES
G
Floor toExchanger
Inlet
I
Floor toExchanger
Outlet (Upper)———
423/4
K
Floor toSpare 3/4" HotWater Conn.
———
177/8
K
Floor toSpare 3/4" Cold
Water Conn.
F
Floor toExchanger
Outlet
E
Floor toCold Water
Conn.351/2457/8641/861
C
Floor toT&P
Conn.
B
JacketDia.
A
Floor toHeater
Top405275119
Gal.Cap.
ModelNumber
J
Floor toExchanger
Inlet (Upper)351/2457/8641/8491/2
D
Floor toHot Water
Conn.19191936
H
Floor toAquastat
Approx.ShippingWeight
Notes:1) Inlet water temperature based on 50°F.2) RTV-119 supplied with 2 extra plugged tappings (see manual).
Height to top spare plug is 413⁄4".Height to bottom spare plug is 17".
3) RTV-119 equipped with steel casing.All potable water connections are 3/4" NPT (11⁄4" on RTV-119).3⁄4" Aquastat tapping.3⁄4" T&P valve tapping.
158200225360
RTV-40-LRTV-52-LRTV-75-LRTV-120-L
AHRI Water Heater Ratings
First HourDelivery
133165165280
ContinuousDraw
@ 135°F(Gal./Hr.)
0.90.70.50.6
StandbyHeat Loss
Rating(°F/Hr.)
88,000113,000113,000195,000
Min. HeatRequired
Rate(BTU/Hr.)
8.08.08.011.0
Min. HeatSource
Flow Rate(Gal./Min.)
ModelNumber
Note: These certified ratings were obtained with a heat output rate and flow rate asspecified and a 180°F boiler water supply temperature. Other results will beobtained under different conditions.
Residential 90/91Storage Tank Models
■ Vitraglas® Lining■ Factory-Installed Hydrojet® Total
Performance System■ Water Connections – 3/4" NPT
Factory-Installed True DielectricFittings (AST-120 has 1" NPTConnections)
■ 2" Non-CFC Foam Insulation■ Fully Automatic Controls■ Protective Magnesium Anode Rod■ Boiler Return Is 3/4"■ Thermal Feet■ T&P Relief Valve Opening■ Brass Drain/Return Valve (3/4")
TOP CONNECTIONS
DRAIN/BOILER RETURN
A C
D
Photo ofAST-50-6
T&P(NOTPROVIDED)
BOILERSUPPLY
OUTLET
B
E
405080119
AST-40-6AST-50-6AST-80-6AST-120-6
467/8465/16
587/8627/8
202224
281/4
477/8475/16
597/8637/8
31/16
31/16
31/16
31/16
103130183305
Storage Tank ModelsDIMENSIONS IN INCHES
C
Floor to Top Water Conn.
B
JacketDia.
A
Floor toHeater Top
GallonCapacity
ModelNumber
D
Floor to Drain/Boiler Return
3/43/43/41
E
Outlet3/43/43/41
F
Heat SourceSupply
3/43/43/43/4
G
Heat SourceReturn
Approx.ShippingWeight (lbs)
Note: Circulator pump and temperature pressure relief valve are NOT included. We recommend you use a stainless steel or low lead circulator pump and relief valve of your choice wheninstalling these storage tanks.
The Bradford White MAGNUM Series® 92/93
If you’re selecting the water heating equipment for an apartment complex, restaurant, laundromat, hotel, school, manufacturing plant or any otherbusiness with a constant high demand for hot water, the Bradford White Magnum Series of commercial water heaters can fill all your requirements. BradfordWhite offers an extensive and comprehensive selection of water heating products for commercial applications. Our commercial and industrial models,known as the MAGNUM Series, include gas and electric light-duty versions, a full complement of high input Energy Saver units, Ultra High Efficiency unit (eF Series�), instantaneous models, booster units and storage tanks. Each and every one is designed and built to the most exacting quality specificationsfor durability, energy-efficiency and top performance.
Everything you needto build magnumprofits for yourbusiness.
RightSpec� commercial sizing and specifying guide offers manyunique features and upgrades. You’ll find it easy to use with completespecifications on the entire Residential and Magnum series line ofcommercial water heaters. The program enables you to determine thecorrect commercial model for any application including restaurants,apartment complexes and laundromats.
This interactive program includes a comprehensive cross referenceguide that makes replacing any commercial or residential water heaterwith a Bradford White model quick and easy. You simply enter the modelyou wish to replace and the software will provide a Bradford Whitesolution.
Visit Bradford White’s Interactive sizing and cross reference program at:www.bradfordwhite.com
RightSpec� - Interactive Sizing and Cross Reference
With RightSpec�, available on the web, you’ll have the sizing solution you need in a fraction of the time it took before.
Commercial Gas 94/95Light Duty Atmospheric Vent High Input Models
■ Bradford White ICONSystem™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Advanced ScreenLok®
Technology Flame ArrestorDesign (LG250H653N)
■ Resettable Thermal Switch(LG250H653NT)
■ Factory-Installed Hydrojet2™ Total PerformanceSystem
■ Vitraglas® Lining■ Side Connections—3/4"
(19mm) NPT
■ Non-CFC Foam Insulation■ Water Connections■ Hand Hole Cleanout■ Protective Magnesium
Anode Rod■ 4" (107mm) “Snap Lock”
Draft Diverter■ T&P Relief Valve—
Installed■ Low Restriction Brass
Drain Valve■ Thermostatic Mixing Valve
(ASSE Approved) included(LG155H803N only)
Photo ofLG2100H853N
K
BC
AJ F
E
D&M
L
NN
H
A
D&M
E
J F
B
H
N N
C
K
L
KB
C
J
F
E L
A
D&M
H
N N
LG155H803NLG250H653N / LG275H763N LG2100H853N
FOR 24/7 EXPERT SUPPORT
PLEASE CALL:
Technical Support:800.334.3393Warranty Support:800.531.2111
Bradford White Contractors!
Bradford White offers expert Technical Service and Warranty Support,24 hours a day, 7 days a week. www.bradfordwhite.com
Now Get Round The Clock,Expert Support
Water heatersdon't have nightsor weekends off.Neither Do We.
FREE Mobile Apps from Bradford White
RightSpec® Cross Reference Guide• Quickly find a Bradford White water heater to replace
any competitor's model
eF Series® Efficiency Calculator• Easily calculates the cost and energy savings you’ll
see by installing Bradford White’s eF Series® UltraHigh Efficiency water heaters
These apps are compatible with Android, Apple iPhone and Apple iPad mobiledevices, and can be downloaded for free by visiting www.bradfordwhite.com.
Warranty Check• Quickly check the warranty status of any Bradford White water heater
Purchase Bradford White Commercial WaterHeaters and earn points for Rewards!*
JOIN NOW!Scan QR Code
Get 25 FREE Bonus Pointsfor Signing Up!
*Program valid only in the USA and Canada
Ultra High Efficiency Water HeatersAvailable in 60-Gallon and 100-Gallon models withBTU/Hr. inputs ranging from 125,000 to 399,999.The eF Series® is one of the most exciting products in the Bradford White
Residential and Commercial line-up. Utilizing exclusive designs and
technologies, the eF Series out performs the competition when it comes
to installation flexibility, quiet operation and, most importantly, efficiency.
Thermal Efficiency Ratings Up To 99.1%
The eF Series® gives home and building owners,engineers and plumbing and heating professionalsreliable, trouble-free performance.
Scan to learn more about Bradford White’s eF Series® water heaters.
65,00080,00076,00085,000
485575100
LG250H653NLG155H803NLG275H763NLG2100H853N
110N/AN/AN/A
60591/2625/869
222224
281/4
4915/16
497/8517/8595/16
193207263424
131413/16
15157/16
4444
Light Duty Atmospheric Vent High Input ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Recovery100°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/AN/A
EnergyFactor
63787482
NatU.S.GPH
53656269
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.565/8
5515/16
59651/2
F
Floor toTop ofHeater
1181116
H
C/L ofWaterConn.
577/8577/8607/16
6615/16
J
Floor toWaterConn.
26257/8271/4311/2
K
Depth131/2157/16
165/81711/16
L
Floor toSpace
Heating Inlet4915/16
497/8517/8505/8
M
Floor toSpace
Heating Outlet3/43/41
11/4
N
NPT
Approx.Shipping
Weight (lbs)
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "N" to "X".For 5 year models, change suffix “3” to “5”. *Based on manufacturer’s rated recovery efficiency. LG2100H853N model features hand hole cleanout.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.NSF kits available.
LG250H653XLG155H803XLG275H763XLG2100H853X
LP GAS MODELS InputBTU/Hr.
61,00078,00076,00088,000
Recovery100°F Rise*
59767485
LPU.S.GPH
49636271
LPImp.GPH
ModelNumber
Commercial Gas 96/97Light Duty TTW® Power Vent Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control
System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Powerful Blower Motor- 10 ft. Power Cord—Included (120 VAC)
■ Horizontal and Vertical Venting■ Advanced ScreenLok® Technology
Flame Arrestor Design■ Flammable Vapor Sensor■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Non-CFC Foam Insulation
■ Water Connections—3/4" NPT ■ 3/4" NPT Side Connections.■ Factory-Installed Heat Traps■ Protective Magnesium Rod.■ T&P Relief Valve■ Low Restriction Brass Drain Valve■ Thermostatic Mixing Valve (ASSE
Approved) included (LG1PV55)
Photo ofLG2PV50H653N
C
J
F
E L
A
D&M
B
H
K
65,00078,00076,000
485575
LG2PV50H653NLG1PV55H783NLG2PV75H763N
112N/AN/A
661/8643/16
697/16
222226
501/84715/16
511/2
186253252
113/4111/2131/2
3 or 43 or 43 or 4
Light Duty TTW® Power Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
Recovery100°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.70N/AN/A
EnergyFactor
637674
NatU.S.GPH
526362
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.563/8545/8591/2
F
Floor toTop ofHeater
11811
H
C/L ofWaterConn.
573/456
603/4
J
Floor toWaterConn.
263/4261/2301/4
K
Depth131/2133/8133/8
L
Floor toSpace
Heating Inlet501/8
4715/16
511/2
M
Floor toSpace
Heating Onlet
Approx.Shipping
Weight (lbs)
3" Vent Pipe
LG2PV50H653NLG1PV55H753NLG2PV75H753N
4" Vent Pipe
†50 ft.7 ft.45 ft.40 ft.35 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
†180 ft.15 ft.175 ft.170 ft.165 ft.
Propane models feature a Titanium Stainless Steel propane burner.For Propane (LP) models change suffix “N” to “X”. For 5 yearmodels, change suffix from “3” to “5”.*Based on manufacturer’s rated recovery efficiency.120 VAC Required for Power Venting / 120 VAC 60HZ 3.1 Amperes. Energy Factor and First Hour Rating is based on the latest AHRIdirectory listings.
Subtract 5ft. for each additional 90° elbow†For high altitude installations, consult the installationinstructions.
LG2PV50H653XLG1PV55H783XLG2PV75H763X
LP GAS MODELS Recovery100°F Rise*
InputBTU/Hr.
567673
58,00078,00075,500
LPU.S.GPH
476361
LPImp.GPH
ModelNumber
Commercial Gas 98/99Light Duty Power Direct Vent Models
■ Bradford White ICONSystem™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Powerful Blower Model
- 10 ft. power cord included(120 VAC)
■ Closed CombustionVenting System
■ Cast Aluminum Air IntakeBoot
■ Horizontal and VerticalVenting
■ Optional Concentric VentKit Termination
■ Flammable Vapor Sensor■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining■ 2" Non-CFC Foam
Insulation■ Water Connections—
3⁄4" NPT■ Side Connections—
3/4" NPT ■ Factory-Installed Heat
Traps■ Protective Magnesium
Anode Rod■ T&P Relief Valve—
Installed■ Low Restriction Brass
Drain Valve Photo ofLG2PDV50H603N
J F
EL
B
D & M
A
K
C
H
60,00080,000
4875
LG2PDV50H603NLG2PDV75H803N
105—
6972
2226
521/4541/4
205392
135/8161/4
3 or 43 or 4
Light Duty Power Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery100°F Rise*
A
Floor toExhaustOutlet
1st HourRating(Gal.)
0.68—
EnergyFactor
5877
NatU.S.GPH
4864
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.583/4623/4
F
Floor toTop ofHeat
67703/8
H
Floor toAir
Intake60
633/4
J
Floor toWaterConn.
305/836
K
Depth153/419
L
Floor toSpace Heating
Return521/4541/4
M
Floor toSpace Heating
Supply
Approx.Shipping
Weight (lbs)
Propane models feature a TitaniumStabilized Stainless Steel propane burner. For Propane (LP) models change suffix“N” to “X”.For 5 year models change suffix from “3”to “5”. *Based on manufacturer’s rated recoveryefficiency.120 VAC Required for Power Venting /120 VAC, 60HZ, 3.1 Amperes.Energy Factor and First Hour Rating isbased on the latest AHRI directory listings.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
3" Vent Pipe
LG2PDV50H603NLG2PDV75H803N
4" Vent Pipe
60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
100 ft.100 ft.7 ft.95 ft.90 ft.85 ft.
Subtract 5ft. for each additional 90º elbow.
Concentric Vent KitTermination
3" Kit
P/N 239-44069-01 291/4
A (in.)
LG2PDV50H603XLG2PDV75H803X
LP GAS MODELS InputBTU/Hr.
Recovery100°F Rise*
5876
60,00078,000
LPU.S.GPH
4863
LPImp.GPH
ModelNumber
Commercial Gas 100/101Light Duty Direct Vent Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Closed Combustion■ Reinforced Seals■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Cast Aluminum Air Intake Boot■ Telescoping Solid Vent Kits■ Flexible Vent Kit■ Side Connections—3/4" NPT
■ 2" Non-CFC Foam Insulation■ Pedestal Base.■ Water Connections—3/4" NPT ■ Factory-Installed Heat Traps
■ Protective Magnesium Anode Rod■ T&P Relief Valve—Installed■ Low Restriction Brass Drain Valve
Photo ofLG2DV50H503N
J
H
F
E L
B
D&MK
C C
A A
K
Flexible Vent Kit (Side View)Telescoping Solid Vent Kit (Side View)
50,00048LG2DV50H503N 93 725/16 min. 22 521/4 217154 6
Light Duty Direct Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery100°F Rise*
A
Floor to C/L ofVent
1st HourRating(Gal.)
0.60
EnergyFactor
47
NatU.S.GPH
39
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.591/8
F
Floor toTop ofHeater
8
H
C/L ofWaterConn.
601/8
J
Floor toWaterConn.
31
K
Depth153/4
L
Floor toSpace
Heating Inlet521/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
All Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.For 5 year models change suffix from "3" to "5".*Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Solid Vent Kit: Part No. 239-51286-00. Flexible Vent Kit: Part No. 239-51287-00.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and ventinginstructions, refer to Installation and Operation Manual. LG2DV50H503N Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
InputBTU/Hr.
48,000LG2DV50H503X
LP GAS MODELS Recovery100°F Rise*
45
LPU.S.GPH
38
LPImp.GPH
ModelNumber
Commercial Gas 102/103Light Duty Ultra Low NOx Atmospheric Vent High Input Models
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Ultra Low NOx Burner with
Primary and Secondary AirDistribution Devices
■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet 2™
Total Performance System■ Vitraglas® Lining■ More Precise Temperature Control ■ Side Connections—3/4" NPT
■ Non-CFC Foam Insulation■ Pedestal Base—ULG250&75■ Water Connections■ Protective Magnesium Anode Rod■ Hand Hole Cleanout■ 4" (107 mm) “Snap Lock”
Draft Diverter■ T&P Relief Valve—Installed■ Low Restriction Brass Drain Valve■ Design Certified by CSA
International (formerly AGA and CGA).
■ ULG250H553N Complies with thelatest Ultra Low NOx requirement(10 ng/J NOx limit),ULG275H763N / ULG2100H853N(14 ng/J NOx limit). Photo of
ULG275H763N
B
C
K
A
J
E F
G
D
H
L
M
C
L
A
J
H
E F
D&G
BK
M
Model ULG2100H853NModels ULG250H3N & ULG275H763N
55,00076,00085,000
4875100
ULG250H553NULG275H763NULG2100H853N
100N/AN/A
605/16
641/8707/16
2226
281/4
497/8539/16
607/16
193263424
111/2151/8163/4
444
Light Duty Ultra Low NOx Atmospheric Vent High Input ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery90°F Rise*
A
Floor to Flue Conn.
1st HourRating(Gal.)
0.60N/AN/A
EnergyFactor
597482
NatU.S.GPH
496269
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.
133/8165/8183/4
F
Floor toSpace
HeatingReturn
497/8539/16
513/4
G
Floor toSpace
HeatingOutlet
563/8601/8681/8
H
Floor toTop ofHeater
5713/16
611/8665/8
J
Floor toWaterConn.
257/16
297/16
311/2
K
Depth
111116
L
C/Lof
WaterConn
3/41
11/4
M
NPT
Approx.Shipping
Weight (lbs)
Available in Natural Gas only.For 5 year models, change suffix from “3” to “5”.*Based on manufacturer’s rated thermal efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Commercial Gas 104/105Light Duty Ultra Low NOx Direct Vent Model
■ Bradford White ICON System™- Enhanced Performance- Advanced Temperature Control System- Intelligent Diagnostics- Separate Immersed Thermowell
■ Ultra Low NOx Burner with Primary andSecondary Air Distribution Devices
■ Closed Combustion■ Reinforced Seals■ Maintenance-Free■ Sight Window■ Factory-Installed Hydrojet® Total
Performance System■ Vitraglas® Lining■ Cast Aluminum Air Intake Boot■ Telescoping Solid Vent Kits■ Flexible Vent Kit■ Side Connections—3/4" NPT■ 2" Non-CFC Foam Insulation
■ Pedestal Base.■ Water Connections—3/4" NPT ■ Factory-Installed Heat Traps■ Protective Magnesium Anode Rod■ T&P Relief Valve—Installed■ Low Restriction
Brass DrainValve—Durabletamperproofdesign.
■ Design Certifiedby CSAInternational(formerly AGAand CGA)
■ Complies withthe latest UltraLow NOxrequirement (10ng/J NOx limit)
Photo ofULG2DV50H453N
J
H
F
E
B K K
A
C
L
D&M
Telescoping Solid Vent Kit (Side View)
Flexible Vent Kit(Side View)
45,00048ULG2DV50H453N 88 741/4 min. 22 521/4 201154 6
Light Duty Ultra Low NOx Direct Vent ModelDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery100°F Rise*
A
Floor to C/L ofVent
1st HourRating(Gal.)
0.60
EnergyFactor
43
NatU.S.GPH
35
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
I.D. O.D.
D
Floor to T&P
Conn.
E
Floor toGas
Conn.591/4
F
Floor toTop ofHeater
11
H
C/L ofWaterConn.
601/8
J
Floor toWaterConn.
305/8
K
Depth153/4
L
Floor toSpace
Heating Inlet521/4
M
Floor toSpace
Heating Outlet
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.*Based on manufacturer’s rated recovery efficiency.Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Solid Vent Kit: Part No. 239-51286-00. Flexible Vent Kit: Part No. 239-51287-00.Kits can be ordered and shipped with water heater, or ordered and shipped separately. For vent kit components and venting instructions, refer to Installationand Operation Manual.
Optional Telescoping Solid Vent Kits:Kit “F” Telescopes from 43⁄4" to 511⁄16" Part No. 239-42516-00Kit “G” Telescopes from 61⁄2" to 93⁄16" Part No. 239-42517-00Kit “H” Telescopes from 133⁄4" to 2311⁄16" Part No. 239-42514-00Kit “I” Telescopes from 4913⁄16" to 9513⁄16" Part No. 239-42512-00
Commercial Gas 106/107Light Duty Ultra Low NOx TTW®
Power Vent Model ■ Ultra Low NOx Burner with
Primary and Secondary AirDistribution Devices
■ Defender Combustion Chamber■ Flammable Vapor Sensor and
Resettable Thermal Switch■ Maintenance-Free■ Sight Window■ Bradford White ICON
System™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Powerful Blower Motor
- 10 ft. Power Cord—Included(120 VAC)
■ Horizontal and Vertical Venting■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining■ Non-CFC Foam Insulation■ Water Connections—3/4"NPT■ Factory-Installed Heat Traps■ Protective Magnesium Anode
Rod■ Pedestal Base■ T&P Relief Valve—Installed■ Low Restriction Brass Drain
Valve■ All Models Comply with the
Latest Ultra Low NOxRequirement (10 ng/J NOxlimit) Except ULG2PV75H763N(14 ng/J NOx limit)
Photo ofULG2PV50H603N
C
A
G
E
D
F
BH
J
56,00076,000
4875
ULG2PV50H563NULG2PV75H763N
99N/A
663/8691/4
2226
497/8517/8
190270
113/4113/4
3 or 43 or 4
Ultra Low NOx TTW® Power Vent ModelDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed80% Recovery Efficiency
Recovery100°F Rise*
A
Floor toVent
Conn.
1st HourRating(Gal.)
0.70N/A
EnergyFactor
5474
NatU.S.GPH
5462
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.565/8591/2
F
Floor toTop ofHeater
5861
G
Floor toWaterConn.
261/2301/4
H
Depth1111
J
C/L ofWaterConn.
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models, change suffix from “3” to “5”.*Based on manufacturer’s rated recovery efficiency.120 VAC Required for Power Venting / 120 VAC, 60HZ, 3.1 Amperes. Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
†For high altitude installations, consult the installationinstructions.
3" Vent Pipe
ULG2PV50H563NULG2PV75H763N
4" Vent Pipe
†50 ft.7 ft.45 ft.40 ft.35 ft.
123
Max. Equivalent LengthMin. Equivalent LengthNumberof90° Elbows
†180 ft.15 ft.175 ft.170 ft.165 ft.
Commercial Gas 108/109Light Duty Ultra Low NOx Power Direct Vent Models
■ Ultra Low NOx Burner withPrimary and Secondary AirDistribution Devices
■ Closed Combustion VentingSystem
■ Bradford White ICONSystem™- Enhanced Performance- Advanced Temperature
Control System- Intelligent Diagnostics- Separate Immersed
Thermowell■ Cast Aluminum Air Intake Boot■ Flammable Vapor Sensor■ Factory-Installed Hydrojet®
Total Performance System
■ Vitraglas® Lining■ Optional Concentric Vent Kit
Termination■ Horizontal and Vertical
Venting■ 2" Non-CFC Foam Insulation■ Water Connections— 3⁄4" NPT ■ Side Connections—3/4" NPT ■ Factory-Installed Heat Traps■ Protective Magnesium Anode
Rod■ T&P Relief Valve■ Low Restriction Brass Drain
Valve■ Complies with the latest
Ultra Low NOx Requirement(10 ng/J NOx Limit)
Photo ofULG2PDV50H503N
H
A
JF
EL
B
D & M
C
K
N
50,00048ULG2PDV50H503N 92 691/4 22 521/4 201137/83 or 4
Light Duty Ultra Low NOx Power Direct Vent ModelDIMENSIONS IN INCHES
NATURAL GAS MODEL
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed78% Recovery Efficiency
Recovery100°F Rise*
A
Floor to ExhaustOutlet
1st HourRating(Gal.)
0.68
EnergyFactor
48
NatU.S.GPH
40
NatImp.GPH
InputBTU/Hr.
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
VentSize
D
Floor to T&P
Conn.
E
Floor toGas
Conn.691/4
F
Floor toTop ofHeater
583/4
H
Floor toAir
Intake60
J
Floor toWaterConn.
32
K
Depth153/4
L
Floor toSpace
Heating Return
521/4
M
Floor toSpace
Heating Supply
91/4
N
C/LDistance
FromIntaketoExhaust
Approx.Shipping
Weight (lbs)
Available in Natural Gas only. For 5 year models change suffix from “3” to “5”.*Based on manufacturer’s rated recovery efficiency. 120 VAC Required for Power Venting / 120 VAC,60HZ, 3.1 Amperes. Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
Subtract 5ft. for each additional 90º elbow.
INTAKE/COMBUSTION
AIR
RAINCAP
VENTEXHAUST
A
3" Vent Pipe
ULG2PDV50H503N
4" Vent Pipe
60 ft.60 ft.7 ft.55 ft.50 ft.45 ft.
123
Max. Intake LengthMax. Exhaust LengthMin. Vent LengthNumberof90° Elbows
100 ft.100 ft.7 ft.95 ft.90 ft.85 ft.
3" Kit
P/N 239-44069-01 361/4
A (in.)
Commercial Gas 110/111Commander Series™ Atmospheric Vent Models
■ ICON HD™
- Operation Mode- Service Mode
■ Optional Air Intake Ducting■ Premix Power Burner■ Direct Spark Ignition■ Integrated Exhaust System■ Sanitizing Capability■ Factory-Installed Hydrojet®
Sediment Reduction System■ Vitraglas®Lining■ Non-CFC Foam Insulation■ Water Connections■ 1" NPT Side Connections for
Space Heating■ 82% Thermal Efficiency■ Zero Inch Clearance to
Combustibles (Excluding UCG-100H-399)
■ Hand Hole Cleanout
■ NSF Construction Available■ T&P Relief Valve■ Low Restriction Brass Drain
Valve■ Ultra Low NOx Construction
(14 ng/J NOx Emissions)■ CSA Certified Low Lead
Content
Photo ofUCG-100H-199-3NJ
H
G
C
E D
A FK
B
199,999270,000399,999
10010098
UCG-100H-199-3NUCG-100H-270-3NUCG-100H-399-3N
731/4731/4771/4
666
521/2521/2521/2
632632657
551/2551/2551/2
10108
Commander Series™ Atmospheric Vent ModelsDIMENSIONS IN INCHES
NATURAL GAS MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed82% Thermal Efficiency
GPH Recoveryat Degree Rise*
A
Floor to Top ofVent
493665994
40ºF197266398
100ºF141190284
140ºFInput
BTU/Hr.Gal.Cap.
ModelNumber
B
Vent Dia.
C
Floorto ColdWaterInlet
D
Floor to T&P
Conn.
E
Floor toHot Water
Outlet
693/4693/4693/4
F
Floor toTop ofHeater
631/4631/4631/4
G
Floor toGas
Conn.
303030
H
Depth
281/4281/4281/4
J
Width
631/4631/4631/4
K
Floor to Cold Water
Inlet/HotWater Outlet
11/211/211/2
WaterConn.Dia.
3/43/43/4
GasConn.Dia.
3/411
ReliefValveOpen
Approx.Shipping
Weight (lbs)
Model
Optional Air Intake Ducting Maximum Lengths
UCG-100H-199-3(N,X)UCG-100H-270-3(N,X)UCG-100H-399-3 (N)
20 ft.20 ft.N/A
50 ft.50 ft.25 ft.
75 ft.75 ft.50 ft.
2" PVC, ABS,or CPVC
3" PVC, ABS,or CPVC
4" PVC, ABS,or CPVC
For Propane Gas models change suffix "N" to "X". Example: UCG-100H-199-3X (Propane Gasnot available on UCG-100H-399-3N). Natural gas models comply with the latest Ultra LowNOx requirements (14 ng/J or less). Amp Draw range = 1.0 to 1.8 amps.
Commercial Gas 112/113Electronic Ignition Water Heaters
■ ICON HD™—Intelligent proven designcombines temperature control,diagnostic codes and system ignitionfunctions into a single control boardwith a digital LCD display- Operation Mode- Service Mode
■ Electronic Ignition■ Automatic Flue Damper
■ Factory-Installed Hydrojet® SedimentReduction System
■ Vitraglas® Lining■ Non-CFC Foam Insulation■ Water connections—Factory-Installed
True Dielectric Waterway Fittings■ Hand Hole Cleanout■ Automatic Re-Set E.C.O.■ Magnesium Anode Rods
■ Sanitizing Capability■ ASME Code Available on All Models
above 200,000 BTU/Hr.■ NSF Construction Available■ Low NOx Construction Available■ North Carolina Code Compliant■ T&P Relief Valve Installed■ Low Restriction Brass Drain Valve
Commercial Gas Burner■ Orifice Alignment Bracket for True Injection■ Stainless Steel Pilot Shield■ Stainless Steel Burner Rack and Mounting
Bracket■ Aluminized Steel Burner Tubes with Adjustable
Air Shutter (Stainless Steel Burner TubesAvailable)
■ Opposing Lance Formed Burner Ports YieldConsistent Performance to Stabilize BurnerFlame and Promote Better Air Gas Mixture
■ Standard on Both “T” and “L” CommercialEnergy Saver Models
Photo ofD-80T-180-3N
Optional Power Vent Kits – available for inputsfrom 125,000 to 505,000.BTU Input Range Kit Number125,000 to 290,000 BTU’s: 239-81764-00300,000 to 399,999 BTU’s: 239-81766-00425,000 to 505,000 BTU’s: 239-82148-00
Typical ApplicationsB
A
H
E
C
F
D
B
J
H
A
E
C
F
D
B
A
H
E
C
F
D
D-38T-155 D-75T-(125, 160)D-80T-(180, 199,250)D-100T-(199, 250)D-100S-(199, 250)D-100L-(199, 250, 270, 300)
D-75T-300D-65T-(370, 399)D-80T-(425, 505)D-80L-(399, 450, 505)
Commercial Gas 114/115Electronic Ignition Models
155,000125,000160,000180,000199,999250,000199,999250,000300,000370,000399,999425,000505,000
38757580808098987565658080
D-38T-155-3N+D-75T-125-3ND-75T-160-3ND-80T-180-3ND-80T-199-3ND-80T-250-3N(A)D-100T-199-3ND-100T-250-3N(A)D-75T-300-3N(A)D-65T-370-3N(A)D-65T-399-3N(A)†D-80T-425-3N(A)D-80T-505-3N(A)
37630338943648560648560672789797010301178
150121155175194242194242291359388412471
10786111124139173139173208256277294337
431/26565
641/2641/2641/2751/2751/2653/4643/4643/4751/2751/2
656666667881010
281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4281/4
–––––
590–
690645720720800800
Electronic Ignition ModelsDIMENSIONS IN INCHES
These models meet or exceed both Thermal Efficiency andStandby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. Listed
H
Floorto Top
ofHeater
B
JacketDia.
GPHRecovery
at °F Rise*
Approx.Shipping
Weight (lbs)
40° 100° 140°Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentDia.
–671/8671/8661/4661/4661/4771/4771/4
–––––
J
Floorto TopWaterConn.
35541/2541/25656566767
541/8541/8541/8641/2641/2
D
FrontHot
WaterConn.
45/843/443/443/443/443/443/443/4101/2101/2101/2101/2101/2
E
Floorto GasConn.
51721/4721/4717/8717/8717/8833/8833/8743/8731/4731/4823/4823/4
A
TopVent
Height193/83434
191/2191/2191/2191/2191/22929292929
F
FrontCold
WaterConn. Std. ASME
11/2 (F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (F)
11/2 (F)
WaterConn.
3/43/43/43/43/43/43/43/43/4
1(N)
438520520540540540610610590665665750750
GasConn.Dia.
3/43/43/43/43/41
3/4111111
ReliefValveOpen.
NATURAL GAS MODELS
1(N)3/4 (LP)
1(N)3/4 (LP)
1(N)3/4 (LP)
199,999250,000199,999250,000270,000300,000399,999450,000505,000
100100100100100100808080
D-100S-199-3ND-100S-250-3N(A)D-100L-199-3ND-100L-250-3N(A)D-100L-270-3N(A)†D-100L-300-3N(A)D-80L-399-3N(A)D-80L-450-3N(A)D-80L-505-3N(A)
48560648560665572797010911224
194242194242262291388436489
139173139173187208277312350
677/8677/8643/4643/4643/4643/4601/4601/4601/4
66666781010
281/4281/4301/4301/4301/4301/4301/4301/4301/4
–702–
765765765835835835
Electronic Ignition ModelsDIMENSIONS IN INCHES
These models meet or exceed both Thermal Efficiencyand Standby Loss Requirements of ASHRAE 90.1b (Current Edition).
H
Floorto Top
ofHeater
B
JacketDia.
GPHRecovery
at °F Rise*
Approx.Shipping
Weight (lbs)
40° 100° 140°Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentDia.
707067676767–––
J
Floorto TopWaterConn.
603/8603/8561/2561/2561/2561/2511/2511/2511/2
D
FrontHot
WaterConn.
45/845/841/241/241/241/2101/2101/2101/2
E
Floorto GasConn.
763/4763/4757575
753/8711/26969
A
TopVent
Height203/4203/4231/2231/2231/2231/2231/2231/2231/2
F
FrontCold
WaterConn. Std. ASME
WaterConn.
3/43/43/43/43/43/4
667667725725725725800800800
GasConn.Dia.
3/41
3/4111111
ReliefValveOpen.
NATURAL GAS MODELS
1(N)3/4 (LP)
1(N)3/4 (LP)
1(N)3/4 (LP)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (F)
11/2 (F)
11/2 (F)
(A) = ASME Code Available(F) = Front Water Connection(T) = Top Water Connection† = Available in Natural Gas Only + = Fiberglass Insulation
For (LP) Propane Gas models change suffix “N”to “X”.
*Based on manufacturer’s rated recovery efficiency.**Recoveries are based on 80% Thermal Efficiency . Low NOx models are not available for inputs over 399,999For Low NOx compliance place an “E” following the BTU input identifier ofthe model number.Example: D-75T-125E-3NAmperage Draw = .5 for damper models/less than 4 for induced draft models.Power Vent Kits – available for inputs from 125,000 to 505,000.
LP GAS MODELSInput
BTU/Hr.GPH Rec.
40° 100º 140ºD-75T-160-3X 155,000 376 150 107
D-80T-250-3X 235,000 570 228 163D-100T-250-3X 235,000 570 228 163D-80L-399-3X 375,000 909 364 260D-80L-450-3X 425,000 1030 412 294D-80L-505-3X 475,000 1152 461 329
Commercial Gas 116/117Induced Draft Models
■ ICON HD™—Intelligentproven design combinestemperature control,diagnostic codes andsystem ignition functionsinto a single control boardwith a digital LCD display- Operation Mode- Service Mode
■ Electronic Ignition■ Factory-Installed
Hydrojet® TotalPerformance System
■ Vitraglas® Lining
■ Automatic Re-Set E.C.O.■ Non-CFC Foam Insulation■ Water Connections—11⁄2"
NPT Front Factory-Installed True DielectricFittings
■ Protective MagnesiumAnode Rods
■ Hand Hole Cleanout■ Sanitizing Capability■ NSF Construction
Available■ ASME Construction
Available■ T&P Relief Valve Installed■ Low Restriction Brass
Drain Valve
E
F
D
A
C
G
39 7/8"DEPTH
B
Photo ofD-65T-625-3NA
625,000725,000
6580
D-65T-625-3N(A)D-80T-725-3N(A)
15151757
606703
433502
693/8795/8
281/4281/4
Induced Draft ModelsDIMENSIONS IN INCHES
These models meet or exceed both Thermal Efficiency and StandbyLoss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. Listed80% Thermal Efficiency
A
Floorto
HeaterTop
B
JacketDia.
GPHRecovery
at °F Rise*
40° 100° 140°
Nat. &LP
InputBTU/Hr.
Gal.Cap.
ModelNumber
88
C
VentDia.
687/8791/8
G
Floorto
VentHeight
541/8641/4
D
Floorto HotWaterConn.
287/8287/8
E
Floorto ColdWaterConn.
101/2101/2
F
Floorto GasConn.
11
ReliefValveOpen
1†1†
GasConn.Dia.
NATURAL GAS MODELS
775880
Approx.Shipping
Weight (lbs)
Std. ASME720800
(A) = ASME Code AvailableFor Propane Gas models change suffix “N” to “X”.†LP Gas connection 3/4".
*Based on manufacturer’s rated recovery efficiency.**Recoveries are based on Thermal Efficiencies of 80%.
Commercial Gas 118/119Millivolt Models
■ No Electricity Required■ ASME Code Available on All Models above 200,000 BTU/Hr.■ Continuous pilot-ignition■ Piezo Igniter - Easy and Quick Lighting by the Pilot Burner by Push Button■ Millivolt Controls■ Automatic Flue Damper■ Vitraglas® Lining■ Factory-Installed Hydrojet® Sediment Reduction System■ Factory-Installed Dielectric Fittings■ Non-CFC Foam Insulation■ Hand Hole Cleanout (Standard)■ NSF Construction Available■ T&P Relief Valve Installed■ Low Restriction Brass Drain Valve■ 3 Year Limited Tank Warranty
Photo ofDM-75T-125-3N
Water ConnectionsTop and FrontDM80T180, 199, 250DM100T199, 250DM75T125, 160Top FrontDM100L199, 250, 270DM100S199, 250
Water ConnectionsFront and RearDM38T155
C
B
F
J
D
E
COLD
HOT
T & P
A
H
CLEANOUT
H
C
B
F
D
E
HOT
T & P
A
J
COLD CLEANOUT
155,000125,000160,000180,000199,999250,000199,999250,000199,999250,000270,000199,999250,000
3875758080809898100100100100100
DM-38T-155-3NDM-75T-125-3NDM-75T-160-3NDM-80T-180-3NDM-80T-199-3NDM-80T-250-3N(A)DM-100T-199-3NDM-100T-250-3N(A)DM-100L-199-3NDM-100L-250-3N(A)DM-100L-270-3N(A)†DM-100S-199-3NDM-100S-250-3N(A)
368303378436485606485606485606655485606
147121151175194242194242194242262194242
10786108124139173139173139173187139173
436565
641/2641/2641/2751/2751/2656565
727/8727/8
6566666666666
281/4281/4281/4281/4281/4281/4281/4281/4301/4301/4301/4301/4301/4
—————590—690—765765—702
Millivolt ModelsDIMENSIONS IN INCHES
These models meet or exceed both Thermal Efficiencyand Standby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. Listed
H
Floorto Top
ofHeater
B
JacketDia.
GPHRecovery
at °F Rise*
Approx.Shipping
Weight (lbs)
40° 100° 140°Input
BTU/Hr.Gal.Cap.
ModelNumber
C
VentDia.
—671/8671/8661/4661/4661/4771/4771/46767677575
J
Floorto TopWaterConn.
341/2541/2541/25656566767
561/2561/2561/2601/2601/2
D
R/FHot
WaterConn.
45/843/443/443/443/443/443/443/441/241/241/241/241/2
E
Floorto GasConn.
51721/4721/4723/8723/8723/8833/8833/8757575
763/4763/4
A
TopVent
Height193/83434
191/2191/2191/2191/2191/2231/2231/2231/2203/4203/4
F
R/FCold
WaterConn. Std. ASME
WaterConn.
3/43/43/43/43/43/43/43/43/43/43/43/43/4
3/43/43/43/43/41
3/41
3/411
3/41
438520520540540540610610725725725667667
GasConn.Dia.
ReliefValveOpen.
NATURAL GAS MODELS
11/211/211/211/211/211/211/211/2
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
11/2 (T&F)
Commercial Gas 120/121Millivolt Models
(A) = ASME Code Available(F) = Front Water Connection(T) = Top Water Connection†= Available in Natural Gas Only For Propane Gas models change suffix “N” to “X”.
For LowNOx compliance, place an “E” following the BTU Input identifier of the modelnumber. Example: DM-75T-125E-3N*Based on manufacturer’s rated recovery efficiency.**Recoveries are based on Thermal Efficiencies of 80%.
LP GAS MODELS InputBTU/Hr.
GPH Rec.40° 100º 140º
DM-75T-160-3X 155,000 376 150 107DM-80T-199-3X 190,000 461 184 132DM-80T-250-3X 235,000 570 228 163DM-100T-250-3X 235,000 570 228 163
Commercial Gas 122/123Ultra High Efficiency Models
■ ICON HD™—Intelligent provendesign combines temperaturecontrol, diagnostic codes andsystem ignition functions into asingle control board with adigital LCD display
■ Up to 99.1% Thermal Efficiency■ ASME Construction Available■ Electronic Controls■ Low-NOx Premix Power Burner■ Three Pass Flue System■ Flexible Venting Options■ Vitraglas® Lining■ Factory-Installed Hydrojet®
Sediment Reduction System■ Factory-Installed Dielectric
Fittings
■ Non-CFC Foam Insulation■ Four Protective Magnesium
Anode Rods (Except EF-100T-399)
■ Two Powered Anode Rods andOne Non-Powered Anode Rodin the EF-100T-399
■ Hand Hole Cleanout■ Zero Inch Clearance
to Combustibles■ NSF Construction Available■ T&P Relief Valve Installed■ Low Restriction Brass
Drain Valve■ Complies with the Latest
Ultra-Low NOx Requirement(14 ng/J NOx Limit)
H
G
C
C
F
E
J
A
B
DCLEANOUT
21/2"
1/2"
MIN.
NPTCONDENSATECONNECTION
11/2"NPT
OUTLET
11/2"NPT
INLET
1" NPTSPACE
HEATINGOUTLET
1" NPTSPACE
HEATINGRETURN
3" PVCEXHAUST
3" PVC INLET 3/4" NPT GAS INLET
T&P VALVE
AIR INTAKE
GAS INLETEXHAUST
81/4"
81/4"
Photo of EF-60T-199E-3N
96.093.092.099.198.597.092.094.0
606060100100100100100
EF-60T-125E-3N(A)EF-60T-150E-3N(A)EF-60T-199E-3N(A)EF-100T-150E-3N(A)EF-100T-199E-3N(A)EF-100T-250E-3N(A)EF-100T-300E-3N(A)EF-100T-399E-3N(A)
3644235584505977358361127
145169223180239294335451
104121159129171210239322
575757
775/8775/8775/8775/8775/8
421/2421/2421/2621/2621/2621/2621/263
281/4281/4281/4281/4281/4281/4281/4281/4
570570570900900900900950
Ultra High Efficiency ModelsDIMENSIONS IN INCHES
These models meet or exceed both Thermal Efficiency
and Standby Loss Requirements of ASHRAE 90.1b (Current Edition). C.E.C. Listed
H
Floor toTop ofHeater
55555555
J
Floor toVent
Conn.
B
JacketDia.
33333333
C
Vent& AirIntakeSize
GPHRecoveryat °F Rise
40° 100° 140°Therm.Eff. %
125,000150,000199,999150,000199,999250,000300,000399,999
InputBTU/Hr.
Gal.Cap.
ModelNumber
G
HotWaterOutletConn.
127/8127/8127/8127/8127/8127/8127/813
F
ColdWaterInlet
Conn.531/2531/2531/2743/4743/4743/4743/4731/4
521/2521/2521/2731/8731/8731/8731/8731/8
E
Floorto GasConn.
A
Floorto AirIntake
3/43/43/43/43/43/43/41
GasConn.Dia.
3/43/43/43/43/4111
ReliefValveOpen
11/211/211/211/211/211/211/211/2
WaterConn.
4040406060606060
D
Floorto T&PValveConn.
Approx.Shipping
Weight (lbs)
NATURAL GAS AND LIQUID PROPANE GAS MODELS
(A) = ASME Code AvailableFor Propane Gas models change suffix “N” to “X” and remove “E” from model number Example: EF-100T-150-3X.Note: The weight is the same for both ASME and Non-ASME models.NSF Compliance Kit—p/n 265-44542-04.**Recoveries are based on the listed Thermal Efficiencies.
Max. Intake LengthMax. Exhaust Length
15 ft.15 ft.
N/A30 ft.
PowerDirect Vent
PowerVent
EF-60T-125
15 ft.15 ft.
N/A30 ft.
PowerDirect Vent
PowerVent
EF-60T-150EF-100T-150
15 ft.15 ft.
N/A30 ft.
PowerDirect Vent
PowerVent
EF-60T-199EF-100T-199
2” Vent Pipe
Max. Intake LengthMax. Exhaust Length
60 ft.60 ft.
N/A120 ft.
PowerDirect Vent
PowerVent
EF-60T-125EF-100T-150
50 ft.50 ft.
N/A100 ft.
PowerDirect Vent
PowerVent
EF-60T-150EF-100T-199
40 ft.40 ft.
N/A80 ft.
PowerDirect Vent
PowerVent
EF-60T-199EF-100T-250
30 ft.30 ft.
N/A60 ft.
PowerDirect Vent
PowerVent
EF-100T-300
25 ft.25 ft.
N/A50 ft.
PowerDirect Vent
PowerVent
EF-100T-399
3” Vent Pipe
Max. Intake LengthMax. Exhaust Length
85 ft.85 ft.
N/A170 ft.
PowerDirect Vent
PowerVent
EF-60T-125EF-100T-150
75 ft.75 ft.
N/A150 ft.
PowerDirect Vent
PowerVent
EF-60T-150EF-100T-199
65 ft.65 ft.
N/A130 ft.
PowerDirect Vent
PowerVent
EF-60T-199EF-100T-250
55 ft.55 ft.
N/A110 ft.
PowerDirect Vent
PowerVent
EF-100T-300
50 ft.50 ft.
N/A100 ft.
PowerDirect Vent
PowerVent
EF-100T-399
4” Vent Pipe
Commercial Gas 124/125Ultra High Efficiency Models
eF Series® Optional Equipment Features:
Maxitrol Gas Pressure Regulating Valve—Ensures proper supplypressure to eF unit of 7" to 11" W.C.(provided incoming pressure isbetween 1/2 and 2 psi). This can be ordered as a separate part, or aspart of the heater. For the separate part, please use p/n 243-45517-00(not available for use with the EF-100T-399).
NSF Compliance Option—p/n 265-44542-04
Low Gas Inlet Pressure Option—Pre-assembled to allow operation atlower inlet natural gas pressure.
Intake/CombustionAir Rain Cap
VentExhaust
36 1/4"
Concentric Vent Terminal Kit—3" termination fitting provides for only oneexit opening through wall or roof (p/n 239-44069-01).
p/n 239-44069-01p/n 239-44069-02 (for 2” vent pipe only)
Commercial Electric 126/127Water Heaters
Incoloy Element Availability Chart
yesnonononononononono
120V1500200025003000350040004500500055006000
Wattsyesyesyesyesyesyesyesyesyesyes
208Vyesyesyesyesyesyesyesyesyesyes
240Vnoyesnoyesnoyesyesyesyesyes
277Vnoyesnoyesnoyesyesyesyesyes
480V
Specify voltage and wattage when ordering.All models are ETL listed. All water connections are 3⁄4" NPT (LE2120T has 1" NPT). All electrical connections are3⁄4". All models are certified at 300 psi test pressure and 150 psi working pressure. All models come equipped withtwo installed heat traps (except LE2120T, LE120L, Utility and Wall Hung models). All models include an installedT&P Relief Valve. Note: All Upright and Lowboys will be wired 240 Volt with two 4500 watt elements, 3 phase non-simultaneousoperation (except 277 volt; 277 volt is only available in single phase operation). Other wattages and voltages areavailable. These models are field convertible to single phase and simultaneous operation. All models have amaximum total wattage of 3000 watts at 120 Volt. Incoloy elements available for most inputs.Note: All Wall Hung and Utility Models will be wired 120 Volt with a 1500 watt element as single phase operation.3 phase wiring not available on Wall Hung or Utility models (Single Element Units). Other wattages and voltagesare available. Maximum wattage for 6 and 12 gallon tall utility models is 3000W. Maximum wattage for 10, 12 and15 gallon utility models is 6000W. Maximum wattage for the 6 gallon wall hung model is 3000W. Maximumwattage for 12, 20 and 30 gallon wall hung models is 6000W. All models have a maximum wattage of 3000 wattsat 120 Volt. Incoloy elements available for most inputs.
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480Vyesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
NOTE: WHEN ORDERING WATER HEATERS SPECIFY VOLTAGE AND kW INPUT ONLY. THE FOLLOWING TABLES ARE FOR INFORMATIONAL PURPOSES ONLY.Phase and Operation are determined by the voltage.All 208V, 240V and 480V models are shipped standard three phase, non-simultaneous.Can be converted to single phase and/or simultaneous operation in the field.All 120V and 277V models are shipped standard single phase, non-simultaneous.Can be converted to simultaneous operation in the field. Three phase not available.
EX: LE250S3-3NCWW EX: LE250S3-3NCWW
EX: LE250S3-3NCWW
EX: LE250S3-3NCWW, will give 240V with 4500W/4500W. This same heater can also be energized at 208V with reduced wattage of 3500W/3500W.**Use “L” voltage designator if wiring 208V with 5000, 5500 or 6000 watt.†Available in non-simultaneous only.
EX: LE250S3-3NCWW*Use “L” voltage designator if wiring 208V with 5000 watt.
For 120V, 277V, 480V, and 600V operation
For 240V and 208V operation (Dual rated elements show a value for both 240V and 208V)
Phase1 Single Phase3 Three Phase
OperationN Non-SimultaneousS Simultaneous
Designator A C E H J L*Voltage 120 208/240 277 480 600 208
Designator J K L M N P R S T W X Y ZWattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 6000
Designator J K L M N P R S T W X Y Z X** Y** Z**240V Wattage 1000 1250 1500 2000 2500 3000 3500 3800 4000 4500 5000 5500 — — — —208V Wattage — — 1000 1500 2000 — 2500 — 3000 3500 — 4000 4500 5000 — —
Commercial Electric 128/129Electri-Flex™ LD (Light Duty) Upright Models
■ Fully Automatic Controls■ Direct Heat Transfer with
Immersed Elements■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining■ 2" Non-CFC Foam Insulation■ Water Connections—3⁄4" NPT■ Factory-Installed Heat Traps ■ Protective Magnesium Anode
Rod■ Steel Tank■ Field Convertible■ Voltages Available—120V,
208V, 240V, 277V, 480V.■ T&P Relief Valve Installed
Photo ofLE250S3-3
C
A
D
B
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
3040506580119
LE230S3-3LE240S3-3LE250S3-3LE265T3-3LE280T3-3LE2120T3-3
467/8467/8461/2591/4591/4623/4
182022222428
473/16
467/8461/2591/4591/4621/4
85103130156183305
481/8477/8471/2601/4601/4641/4
Electri-Flex™ LD (Light Duty) Upright ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery100°F Rise*
A
Floor toHeater Top
181818181818
NatU.S.GPH
151515151515
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor toWater Conn.
D
Floor toT&P Conn.
Approx.Shipping
Weight (lbs)
Specify wattage and voltage when ordering. Use chart below for maximum wattages at certain voltagesFor 5 year models, change suffix "3" to "5".*Based on 4500W/4500W, Non-Simultaneous operation.NSF Kits available when ordering.
▲ (GPH basedon Non-Simultaneousoperation, whenSimultaneousoperation theGPH willapproximatelydouble.)
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480Vyesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
Recovery▲GPH Temperature Rise ºF
60 80 90 100 120Wattage
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Commercial Electric 130/131Electri-Flex™ LD (Light Duty) Lowboy Models
■ Fully Automatic Controls■ Direct Heat Transfer with
Immersed Elements■ Factory-Installed Hydrojet®
Total Performance System■ Vitraglas® Lining■ 1" Non-CFC Foam Insulation■ Water Connections—3⁄4" NPT ■ Factory-Installed Heat Traps■ Protective Magnesium Anode
Rod■ Steel Tank■ Field Convertible■ Voltages Available—120V,
208V, 240V, 277V, 480V.■ T&P Relief Valve Installed
Photo ofLE120S3-3
C
A
D
B
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
19304047
LE120L3-3†LE130L3-3LE140L3-3LE150L3-3
243/4293/4311/4313/4
18202224
191/4 / 247/824 / 293/8
241/8 / 313/4241/8 / 313/4
5886115140
2631
327/8331/8
Electri-Flex™ LD (Light Duty) Lowboy ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery100°F Rise*
A
Floor toHeater Top
18181818
NatU.S.GPH
15151515
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor toWater Conn.
D
Floor toT&P Conn.
Approx.Shipping
Weight (lbs)
▲ (GPH basedon Non-Simultaneousoperation, whenSimultaneousoperation theGPH willapproximatelydouble.)
Wattage Limitations for Non-Simultaneousand Simultaneous Operation
Voltage120V 208V 240V 277V 480Vyesnonononononononono
yesyesyesyesyesyesyesyesnono
yesyesyesyesyesyesyesyesyesno
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
Recovery▲GPH Temperature Rise ºF
60 80 90 100 120Wattage
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Specify wattage and voltage when ordering.Use the charts to the right for maximum wattages at certain voltages.All Models include supplied insulation blanket.For 5 year models, change suffix "3" to "5".*Based on 4500W/4500W, Non-Simultaneous operation.NSF Kits available when ordering.†Exempt from ASHRAE 90.1b.
Commercial Electric 132/133Electri-Flex™ LD (Light Duty) Utility Models
■ Fully Automatic Controls■ Direct Heat Transfer with a
Single Immersed Element■ Vitraglas® Lining■ 1" Non-CFC Foam Insulation■ Water Connections—3/4" NPT ■ Alternate Top Water
Connections■ Protective Magnesium Anode
Rod■ Steel Tank■ Voltages Available—120V,
208V, 240V, 277V, 480V■ Single Phase Operation Only■ T&P Relief Valve
Photo ofLE112T3-1
B
C D
F
E
A
B
F
F
C
E
D
A
4" ALTERNATECOLD INLET(PLUGGED)6 & 12 GAL.
ONLY
PLUG TYPEANODE6 & 12
GAL. ONLY
ALTERNATE HOTOUTLET (PLUGGED)
6 & 12 GAL. ONLY
8"
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request) 6, 12, & 20 Gallon Models
10 & 15 Gallon Models
610121519
LE16U3-1†LE110U3-1LE112T3-1†LE115U3-1LE120U3-1
161/2171/2273/4201/4243/4
1416141818
101/814
211/8
163/4181/4
3348485559
101/815
211/8173/4181/4
Electri-Flex™ LD (Light Duty) Utility ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery100°F Rise*
A
Floor toHeater Top
66666
NatU.S.GPH
55555
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Floor to Hot Water Conn.
31/8
511/16
361/83
E
Floor to ColdWater Conn.
161/2
911/16
273/4101/8101/4
F
Floor toAnode Rod
D
Floor toT&P Conn.
Approx.Shipping
Weight (lbs)
WattageLimitations 120V 208V 240V 277V 480V
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
VoltageRecovery
GPH Temperature Rise ºF
60 80 90 100 120Wattage
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Specify wattage and voltage when ordering.Use chart to right for maximum wattages at certain voltages.†Maximum wattage at any voltage is 3000W.For 5 year models, change suffix "3" to "5".Single element only.*Based on 1500W operation.NSF Kits available when ordering.
Commercial Electric 134/135Electri-Flex™ LD (Light Duty) Wall Hung Models
■ Fully Automatic Controls■ Direct Heat Transfer with a Single
Immersed Element■ Vitraglas® Lining■ 1" Non-CFC Foam Insulation■ Factory-Installed Heavy-Duty Wall
Mounting Bracket
■ Water Connections—3/4" NPT ■ Protective Magnesium Anode Rod■ Steel Tank■ Voltages Available—120V, 208V,
240V, 277V, 480V■ Single Phase Operation Only■ T&P Relief Valve
Photo ofLE16WV3-1
TOPVIEW
D
C
WALL
HOTOUTLET
COLDINLET
ELECTRICAL JUNCTION BOX
8"
A AFRONTVIEW
1213/16"D
HOT OUTLET3/4" CONN.
COLD INLET3/4" CONN.
E
3/4" RELIEF VALVE OPENING
SIDEVIEW
WALL
B
BOTTOMVIEW
FRONT
HEATINGELEMENT &THERMOSTATACCESS
B
Copper Screw Type Immersion Element(Incoloy type immersion element available upon request)
61219
LE16WV3-1†LE112WV3-1LE120WV3-1
153/4163/8243/8
141818
113/4123/4181/4
334859
145/8185/8185/8
Electri-Flex™ LD (Light Duty) Wall Hung ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed79% Recovery Efficiency
Recovery100°F Rise*
A
Height666
NatU.S.GPH
555
NatImp.GPH
Gal.Cap.
ModelNumber
B
Jacket Dia.
C
Wall toFront
117/8
121/221
E
Height toT&P Conn.
D
Height toBracket
Approx.Shipping
Weight (lbs)
WattageLimitations 120V 208V 240V 277V 480V
yesyesyesyesnononononono
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesyesyesyesyesyesyes
yesyesyesyesnoyesyesyesnoyes
yesyesyesyesnoyesyesyesnoyes
1500W / 1500W2000W / 2000W2500W / 2500W 3000W / 3000W 3500W / 3500W 4000W / 4000W 4500W / 4500W 5000W / 5000W 5500W / 5500W 6000W / 6000W
VoltageRecovery
GPH Temperature Rise ºF
60 80 90 100 120Wattage
10141721242831343841
8101315182123262931
791114161821232528
681012141619212325
57910121415171921
1500W2000W2500W3000W 3500W4000W4500W 5000W5500W6000W
Specify wattage and voltage when ordering. Use chart to right formaximum wattages at certain voltages. †Maximum wattage at any voltage is 3000W.For 5 year models, change suffix "3" to "5".Single element only.*Based on 1500W operation.NSF Kits available when ordering.
Commercial Electric 136/137Electri-Flex™ MD (Medium Duty) Models
■ Vitraglas® Lining■ Factory-Installed Hydrojet® Total
Performance System■ Water Connections – 11⁄4" NPT Factory-
Installed Dielectric Waterway Fittings■ 2" Non-CFC Foam Insulation■ Fully Automatic Controls (180°F maximum)■ Direct Heat Transfer with Immersed
Elements■ Protective Magnesium Anode Rod■ T&P Relief Valve Factory Installed■ Low Restriction Brass Drain ValveOptional
Field Conversion Kits; see next page forpart numbers.NSF Construction Kits; see next page forpart numbers.
A&DC E
3 1/8"
Photo ofE32-80R-3
B
F
10"
8"
5080119
E32-50S-3E32-80R-3E32-120R-3
2224
281/4
461/25963
137190312
245/8263/4307/8
Electri-Flex™ MD (Medium Duty) ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedRecovery Efficiency ranging up to 78% (M-I-75 and M-I-100 have an 80% recovery efficiency.)
B
JacketDia.
GallonCapacity
ModelNumber
A
Floor toHeater Top
471/26064
C
Floor toWater Conn.
447/8573/8613/8
E
Floor to Control Box
475/8601/8641/8
D
Floor toT&P Conn.
F
Control Boxto Back
of Heater
Approx.Shipping
Weight (lbs)
All Medium Duty heaters are wired 240V/3 phase 18 kW.Other voltages, wiring phase and kW are available and must be specified when ordering.NOTE: Refer to pages 128/129 for technical information and pages 148/149 for GPHrecovery information.
RequiredTotal
HeaterWattage
ElementWattage
Kit Part Numbers
208V
Conversion Kit Table
240V 480V60009000
12000135001500018000
200030004000450050006000
265-43942-13265-43942-14265-43942-15265-43942-16265-43942-17265-43942-18
265-43942-07265-43942-08265-43942-09265-43942-10265-43942-11265-43942-12
265-43942-01265-43942-02265-43942-03265-43942-04265-43942-05265-43942-06
208V 240V 277V
Full Load Amperes - (Single Phase / Three Phase) and Recovery at a 100°F Rise
380V 415V 480V Recovery86.5/50
28.8/16.6
Input kW186
75/43.425/14.4
6421.6
2810
258.3
37.5/21.612.5/7.2
74 GPH25 GPH
ModelNumber Kit Part Numbers
NSF Construction Kit
E32-50SE32-80RE32-120R
265-45446-01265-45446-02265-45446-03
1,000 watts = 1kW
Commercial Electric 138/139Surface and Immersion Thermostat Models
Immersion Thermostat withContactors■ Immersion Type Thermostat
for Accurate TemperatureControl from Positive off upto 180°F
Surface Mounted Thermostats■ Thermostat Step Control Can
Be Accomplished by VariableSettings
All Models Feature■ Vitraglas® Lined Tank■ Factory-Installed Hydrojet®
Sediment Reduction System■ Completely Pre-wired with
Pressure Lug Terminal orFuse Block Eliminating theNeed for Splicing or TapingWires
■ Water Connections – 11⁄2"NPT Factory-InstalledTrue Dielectric Fittings
■ 3" Non-CFC Foam Insulation■ Two Protective Magnesium
Anode Rods■ Hand-hole Cleanout Opening■ Low Restriction Brass Drain
Valve■ T&P Relief Valve InstalledOptions■ ASME & NSF Construction
Available on Immersion andSurface Thermostats
E C
DA
Hot
B
T&PValve
ColdWaterSupply
F
Photo ofM-II-50-36-3SF
5080119
M-II-50-kW-3SFM-II-80-kW-3SFM-II-120-kW-3SF
473/4601/4641/2
461/2461/2501/4
2426
301/4
Surface and Immersion Thermostat ModelsDIMENSIONS IN INCHES Meet or exceed ASHRAE 90.1b (current standard). C.E.C. Listed
A
Floor to Heater
Top
B
JacketDia.
Gal.Cap.
ModelNumber
E
Floor toTop ofControl
Box63/463/463/4
F
Floor toCold
WaterInlet
491/4613/466
D
Floor toHot
WaterOutlet
41521/255
C
Floor toT&P
Conn.
ELECTRIC MODELS
302378485
Approx.Shipping
Weight (lbs)
Std. ASME270335430
Model numbers shown are for Surface Mount thermostats. For Immersion thermostat change suffix “SF” to “CF”.Voltage and phase must be specified when ordering. Example: M-II-50-12-3SF, 240 Volt, 3 phase.All models available in 208/240/277 and 480 volt.(A) ASME Construction available.For ASME construction add “A” to the model number.Example: M-II-50A-12-3SF, 240 Volt, single phase.NOTE: Refer to pages 128/129 for technical information and pages 148/149 for GPH recovery information.
HOT
COLD45°
15 1/8"
22 1/8"19 1/2"
HOT
COLD 52°
13"
56°T & P 47°
T & P
HOT
COLD 58°
12"
18 1/2"
63°T & P
M-II-50 M-II-80 M-II-120
Commercial Electric 140/141ASME Models
Standard Features:■ Immersion Thermostat with
Contactors - Immersion TypeThermostat for AccurateTemperature Control fromPositive Off up to 180°F
■ ASME Code Construction■ Vitraglas® Lining■ Factory-Installed Commercial
Hydrojet® Sediment ReductionSystem
■ Completely Pre-Wired WithPressure Lug Terminal or FuseBlock Eliminating the need forSplicing or Taping Wires
■ Factory Installed DielectricFittings
■ Non-CFC Foam Insulation2" For 6-40 Gallon3" For 50-119 Gallon
■ Protective Magnesium Anode Rod■ Handhole Cleanout Opening (20
thru 120 Gallon Models Only)■ T&P Relief Valve Installed■ Low Restriction Brass Drain ValveOptions:■ Low Water Cut-Off Switch■ Safety Door Interlock■ High and Low Pressure Limit
Switches■ Alarm Horn■ Temperature and Pressure Gauge■ Time Delay Step Sequences
(24kW and Above)■ NSF Construction
T&P
DRAIN
HI/LOWPRESSURE
B
A
E
ANODE
T&P VALVE
OUTLET
F
D
C
CLEANOUTNOTAVAILABLEON 6/12 GAL.
Photo of30A-36-3
39183636818181
6122030405080119
6A-kW-312A-kW-320A-kW-330A-kW-340A-kW-350A-kW-380A-kW-3120A-kW-3
171/428
271/238
481/4473/4601/4641/2
16162020202426
301/4
1728273838
461/2461/2501/4
181/16
2815/16
28401/4501/2503/8617/8665/16
83118145180220270335430
61/461/461/461/461/4666
181/4 29
281/239
491/4491/4613/466
ASME ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS A
Floor to Heater
Top
B
JacketDia.
Max.kW Input
Gal.Cap.
ModelNumber
C
Floor to Top of
Control Box
D
Floorto HWOutlet
E
Floorto T&PValve
F
Floorto CWInlet
3/43/43/43/43/411/211/211/2
WaterConn.
Approx.Shipping
Weight (lbs)
COLDCOLD
HOT
78°
10"
14 1/2"
20A, 30A, 40A
13"
HOT
87°
8"
12A
87°78°
COLD
T & P T & P T & P
DRAIN
HOT
75°
8"
13"
6A
75° DRAINDRAIN
HOT
COLD45°
15 1/8"
22 1/8"
120A
19 1/2"
HOT
COLD 52°
13"
80A
56°T & P 47°
T & P
HOT
COLD 58°
12"
18 1/2"
50A
63°T & P
NOTE: Refer to pages 148/149 for GPH recovery information.
Commercial Electric 142/143Brute Vertical Round Models
Standard Features:■ 125 psi ASME Code Enamel
Lined Tank■ Incoloy Heating Elements■ Internal Fusing■ Galvanized Steel Jacket■ Magnesium Anode Rods■ Immersion Thermostat■ Manual Reset High Limit■ Hinged Door with
Keyed Lock■ Temperature and Pressure
Relief Valve■ Channel Iron Skid Base■ Hand Hole Cleanout■ 180°F Operation■ Three Year Limited
Warranty■ Meets or Exceeds ASHRAE
90.1b (Current Edition)
Optional Equipment Features:■ Low Water Cut-Off■ Pilot Lights■ Manual Limiting Switches■ Alarm Bell■ Low or High Pressure
Switch■ Time Clock (7 Day or 24
Hour)†
■ Safety Door Interlock■ Temperature and Pressure
Gauge■ Manhole Cleanout (250
Gallons and Larger)■ 150 psi Working Pressure■ Electronic Sequencer (36kW
& Higher)■ Shunt trip disconnect†
■ BMS Relay†Separate mounting
TEMPERATURE& PRESSURERELIEF VALVEHOT
WATEROUTLET
HANDHOLECLEANOUT
DRAIN
COLDWATERINLET TOP VIEW
6 1/4"
D
HINGED DOORTO ELECTRICALCOMPARTMENT
B
E
A
CPhoto of
VR-200-36
1502002503004005006008001000
VR-150-kWVR-200-kWVR-250-kWVR-300-kWVR-400-kWVR-500-kWVR-600-kWVR-800-kWVR-1000-kW
383/4 383/4 403/4 463/4523/4 523/4 603/4 603/4 603/4
323234404646545454
73/473/4191/221
221/2221/2241/2241/2241/2
6507501165135015901700201024503160
161717202323272727
651/2 789280809292104128
Vertical Round ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS D
Depth135180216270360396396396396
Max.kW Load**
Gal.Cap.
ModelNumber
B
Jacket
Diameter
A
Floor toTop ofHeater
C
Floor toCold Water
Inlet
E
Back of Heaterto Cold
Water Inlet11/211/211/2222
21/221/221/2
WaterConn.
Approx.Shipping
Weight (lbs)
On 250 gallon model and larger dimensions: include channel iron legs (not shown).NOTE: Refer to pages 148/149 for GPH recovery information.All horizontal models must be with square jackets.**Vertical Round models above 90kW at 208V, 240V and 162kW at 480V exceed the capacity of a single control box and may require multiple control panels. Consult factory for specific detailsand optional construction.
Commercial Electric 144/145Brute Horizontal & Vertical Models
■ Meets ASHRAE 90.1b (CurrentEdition) Energy Efficiency Standards
■ Immersion Thermostats■ Incoloy Elements■ Internal Fusing■ Enamel Lined Tank■ Built-in Safety Drain Pan■ Magnesium Anode Rods■ Galvanized Jacket■ Key Hinged Door with Lock■ Temperature and Pressure
Relief Valve■ 180°F Temperature Operation■ Hand Hole Cleanout■ Channel Iron Skid Base■ 125 psi ASME Construction■ UL Listed■ Three Year Limited Warranty
Optional Features■ Alarm Bell■ Time Clock (Separate Mounting)■ Electronic Sequencer■ Combination Temperature and
Pressure Gauge■ Low or High Pressure Switch■ Pilot Lights■ Manual Limiting Switches■ Safety Door Interlock■ Low Water Cut-Off■ Shunt Trip Disconnect■ Man Hole Cleanout
(250 Gallons and Larger)■ 150 psi ASME Construction
Horizontal Square
Vertical Square
E
H
DHot Water Outlet
Hot Water Outlet Temperature & PressureRelief ValveExtra Panel Box
Cold Water Inlet
DrainDrain PanConnection
Electric Access
Manhole CleanOut - 250 GAL.& Larger
Cold Water Inlet
Drain
Drain PanConnection
Hinged Door toElectric ControlCompartment
Temperature &PressureRelief Valve
Manhole
Extra panel box may be necessary forhigher than 72 kW. Consult factory.
Cold WaterInlet
Additional HeightIf Required
OptionalManholeEnd View
4"
2 1/8"
7"
8" 1,000-2,500 GALLONS
Extra panel box may be necessary for 72kW andabove on 208V and 144kW and above on 480V
1,000-2,500 GALLONS
HorizontalModels
VerticalModels
W
H
E
W N
K
D
J
180225270360450540720900900900900900
20025030040050060075010001250150020002500
H-200-(kW)H-250-(kW)H-300-(kW)H-400-(kW)H-500-(kW)H-600-(kW)H-800-(kW)H-1000-(kW)H-1250-(kW)H-1500-(kW)H-2000-(kW)H-2500-(kW)
78901/4781/4781/4903/4903/41021/41381/41301/41261/4 1381/4 1441/4
341/4 361/4 421/4 481/4 481/4 541/4 541/4 541/4 601/4 661/4 721/4 781/4
1213
143/41616
131/2131/2123/413
121/2131/2133/4
137014501530175018602340285030403750434045806060
22222
21/221/221/23333
37394552525858
571/2631/2721/2751/2811/2
Horizontal Square Electric ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
WMax.kW Load
Gal.Cap.
ModelNumber
D H EWaterConn.Inlet
222222223333
WaterConn.Outlet
Approx.Shipping
Weight (lbs)
Commercial Electric 146/147Brute Horizontal & Vertical Models
900900900900
1250150020002500
V-1250-(kW)V-1500-(kW)V-2000-(kW)V-2500-(kW)
641/2701/2761/2821/2
641/2 701/2761/2821/2
231/4251/4271/429
3560412043505750
323/16
353/16
383/16
413/16
1321/21281/21401/21461/2
Vertical Square Electric ModelsDIMENSIONS IN INCHES
ELECTRIC MODELS
WMax.kW Load
Gal.Cap.
ModelNumber
D H E K
48466066
N
48466066
J
3333
WaterConnections
Approx.Shipping
Weight (lbs)
NOTE: Refer to pages 148/149 for GPH recovery information.
kWInput
Gallon Per Hour Recovery Capacities
40°F1
1.52
2.53
3.54
4.55
5.56912
13.515182427
10.315.520.725.831.136.241.446.551.756.962.193.1124140155186248279
60°F6.910.313.817.220.724.127.631.134.537.941.462.18393103124165186
90°F4.66.99.211.513.816.118.420.723.125.327.641.455626983110124
100°F4.16.28.310.312.414.516.518.620.722.724.837.25056627499112
140°F2.94.45.97.48.910.311.813.314.716.217.726.5354044537180
GPH Recovery Table 148/149for kW Input
kWInput
Gallon Per Hour Recovery Capacities
40°F3036455481144162180225270360396450540630720900
310372465558838148916751861232627923722409446535583651474449306
60°F20724831037255899311171241155018612482273031023722434349636204
90°F138165207248372662744827103312411654182020682482289533094136
100°F12414918622333559667074493111171489163818612233260629783722
140°F891061331602394254795326657981063117013291595186121272659
GPH Recovery Table
Commercial PowerStor Series® 150/151Single-Wall Indirect Models
Photo ofSW-65C-5
■ Heat Exchanger - Single Wall 11⁄2" O.D.Enamel Coated (Vitraglas®) Steel Coil
■ Vitraglas® Lining■ Factory-Installed Hydrojet® Total
Performance System■ Water Connections – 1" NPT Factory
Installed True Dielectric Fittings ■ 1" NPT Connection for Boiler Supply and
Return■ 2" Non-CFC Foam Insulation■ Immersion Type Aquastat – Accurate
Temperature Control■ Three Protective Aluminum Anode Rods■ T&P Relief Valve Included■ Low Restriction Brass Drain Valve■ 5 Year Tank and Heat Exchanger Warranty
■ AHRI Certified Water Heater Ratings■ Stand-by Heat Loss Is Less than
1/2°F per Hour (ASHRAE 90.1b Current Standard)
DF
EG G
C CA
SW-65C-5SW-80C-5SW-120C-5
B
ANODE RODS(TYPICAL)
POTABLECONNECTIONS
(TYPICAL)
5873114
SW-65C-5SW-80C-5SW-120C-5
2224
281/4
591/459
621/2
531/8527/8553/4
60593/4631/4
273300422
473/4473/4483/4
PowerStor Series® Single-Wall Indirect ModelsDIMENSIONS IN INCHES
C
Floor toT&P
Conn.
A
Floor toHeater
Top
B
JacketDia.
GallonCapacity
ModelNumber
D
Floor toWaterConn.
53/853/863/8
E
Floor toExchanger
Outlet
F
Floor toExchanger
Inlet111/2111/2111/2
G
Floor to Aquastat
Approx.Shipping
Weight (lbs)
ModelNumber 140°F 115°F
DOE Water Heater Performance
SW-65C-5SW-80C-5SW-120C-5
Maximum FirstHour Rating
(Gal.) @
534546583
820834871
ApproximateBoiler OutputNeeded for
Rating (BTU/Hr.)420,000420,000420,000
ModelNumber
AHRI Water Heater Ratings
SW-65C-5SW-80C-5SW-120C-5
First HourDelivery
405415445
ContinuousDraw Rating
@ 135°F(Gal./Hr.)
370370370
HeatSource
Flow Rate(Gal./Min.)
14.014.014.0
HeatReq.Rate
(BTU/Hr.)245,000245,000245,000
StandbyHeat Loss(°F/Hr.)
0.70.60.4
Note: Pressure Drop across commercial models is 2.3ft w.c. at 12 gpm for 200°F Boiler Supply.
Note: These certified ratings were obtained with a heat source output rate and flowrate as specified and a 180ºF boiler water supply temperature. Other results will beobtained under different conditions.
Commercial 152/153Jacketed Storage Tank Models
■ Vitraglas® Lining■ Optional ASME Construction Available■ 2" Non-CFC Foam Insulation■ Water Connections – 2" NPT Factory-
Installed True Dielectric Fittings(M-3-ST120R5A and M-3-ST200R5AHave 21⁄2" Connections)
■ Rear Connection – 2" NPT Spud Allowsfor Rear Water Connection(M-3-ST120R5 and M-3-ST120R5A only)
■ Hand Hole Cleanout (M-3-ST120R5 HasOptional Hand Hole Cleanout)
■ Two Magnesium Anode Rods■ Steel Tank■ 1" Side T&P Valve Opening■ 3/4" NPT Aquastat Connection■ Low Restriction Brass Drain Valve
A
FRONT REAR
DC
EF
GH
J
Photo ofM-3-ST80R5
B
8080119119200
M-3-ST80R5M-3-ST80R5A*M-3-ST120R5M-3-ST120R5A*M-3-ST200R5A*
2424282832
583/4583/4621/2621/277
521/2521/2553/4553/466
593/4593/4631/2631/278
192278312366541
91/491/491/291/2111/4
Jacketed Storage Tank ModelsDIMENSIONS IN INCHES
C
Floor toT&P Valve
A
Floor toHeater
Top
B
JacketDia.
GallonCapacity
ModelNumber
D
Floor toHot Water
Conn.——91/291/2—
J
Floor toRear Water
Conn.2(F&T)2(F&T)
2(F&T), 2(R)2 1/2(F&T), 2(R)
2 1/2(F&T)
WaterConn.Size†
141/4141/4141/2141/2161/4
E
Floor to Aquastat
Top Circ. Conn.
F
Floor to Bottom
Circ. Conn.43/443/455
63/4
G
Floor toDrain Valve
71/471/4—71/291/4
H
Floor toHand Hole Cleanout
Approx.Shipping
Weight (lbs)
HOT OUTLET
HOT OUTLET
COLD INLET
COLD INLET
COLD INLET
SHUTOFFVALVE
SHUTOFFVALVE
SHUTOFFVALVE
CHECKVALVECHECK
VALVE
T & PT & P
T & P
T & PT & P
T & P
THERMOSTAT THERMOSTAT AQUASTAT
RECIRCULATINGLOOP
ALL BRONZECIRCULATOR ALL BRONZE
CIRCULATORALL BRONZECIRCULATOR
HH
C
BOILERTANKLESSCOIL
RECIRCULATINGLOOP
ALL BRONZECIRCULATOR
ALL BRONZECIRCULATOR
AQUASTATAQUASTAT
HOT OUTLET
*Meets ASME Code† (F) = Front water connections
(R) = Rear water connections(T) = Top water connections
Commercial Large Volume 154/155Jacketed Storage Tank Models
■ Vertical or Horizontal Construction■ Water Connections — Two Female 3" NPT Fittings Are Located on the Front
for Ease of Service and Installation ■ ASME Construction■ Available with Vitraglas® Lining, Double Vitraglas® Lining, Epoxy Lining, or
Stainless Steel Tank■ Hydrojet® HC — Optional■ 2" High Density Insulation■ Protective Magnesium Anode Rod(s)■ ASME Tested and Certified to 125 psi■ Steel Jacket■ Designed for Storage of Potable Water up to 180°F■ 5 Year Tank Warranty
Photo ofNV310JG5A
A
C
B
Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles
• Extra Tappings (1"-4")Sizes must be specifiedwhen ordering
• Flanged Connections(3"-10")
• Stainless Steel Construction• 150 psi (add suffix -5)• Hydrojet® HC(add suffix -1)
Manway inspection port is provided as standard equipment on epoxy lining.Options must be specified when ordering
Commercial Large Volume 156/157Jacketed Storage Tank Models
175210240280285310320340360415435453465
N†175J*5AN†210J*5AN†240J*5AN†280J*5AN†285J*5AN†310J*5AN†320J*5AN†340J*5AN†360J*5AN†415J*5AN†435J*5A N†453J*5AN†465J*5A
718393107808611993981108989122
438493539603667710658760796881917942967
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
34343434404034404040464640
B
JacketDia.
Actual U.S.Capacity
Gal.193229260303318344340375397449486504502
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height677989103768211589941068588118
Horiz.Length
A
191/2191/2191/2191/22121
191/2212121
221/2221/221
C
Floor to Inlet
21/221/221/221/221/221/221/221/221/221/233
21/2
Hot WaterOutlet Conn.
Approx. ShippingWeight (lbs)
@125 PSI
500505515575580645675720765790840875104012451530
N†500J*5AN†505J*5AN†515J*5AN†575J*5AN†580J*5AN†645J*5AN†675J*5AN†720J*5AN†765J*5AN†790J*5AN†840J*5AN†875J*5AN†1040J*5AN†1245J*5AN†1530J*5A
8110113411392125104137116147128107149124148
117610171053111713101217145613171602140017481776200333263541
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
524640465246524652465258526464
B
JacketDia.
Actual U.S.Capacity
Gal.572558555630658702752774846846940981112813951689
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height779713010988121100133112143124103145120144
Horiz.Length
A
24221/221
221/224
221/224
221/224
221/224
271/2242927
C
Floor to Inlet
33
21/2333333333333
Hot WaterOutlet Conn.
Approx. ShippingWeight (lbs)
@125 PSI
* = Tank Lining/ConstructionG = Vitraglas®
D = Double Vitraglas®
E = EpoxyS = Stainless Steel Example of full model number when ordering (NV240JG5A)
† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.
Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining
Commercial Large Volume 158/159Unjacketed Storage Tank Models
■ ASME Construction■ Available with Vitraglas® Lining, Double Vitraglas® Lining, Epoxy Lining, or Stainless Steel Tank■ Hydrojet® HC — optional■ Magnesium Anode Rod(s) — for Protection and Longer Service Life■ ASME Tested and Certified to 125 psi■ Red Oxide Primer — Completely Covers Exterior of Tank■ 6" Skirt Height (Vertical Tank) Allows for Easier Access to Areas Under the Tank■ Lifting Lugs■ Designed for Storage of Potable Water up to 180°F■ 5 Year Tank Warranty
A
C
B
E
E
Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles
• Extra Tappings (1"-4")Sizes must be specifiedwhen ordering
• Flanged Connections(3"-10")
• Stainless Steel construction• 150 psi (add suffix -5)• Hydrojet® HC(add suffix -1)
Manway inspection port is provided as standard equipment on epoxy lining. Options must bespecified when ordering
175210240280285310320340360415435453465500505515575580
N†175N*5AN†210N*5AN†240N*5AN†280N*5AN†285N*5AN†310N*5AN†320N*5AN†340N*5AN†360N*5AN†415N*5AN†435N*5AN†453N*5AN†465N*5AN†500N*5AN†505N*5AN†515N*5AN†575N*5AN†580N*5A
677989103768211589941068588118779713010988
3033473834335505274765695596716958057439288748158631045
Vertical and Horizontal ModelsDIMENSIONS IN INCHES Meet or exceed ASHRAE 90.1b (current standard)
303030303636303636364242364842364248
B
JacketDia.
Actual U.S.Capacity
Gal.193229260303318344340375397449486504502572558555630658
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height63758599457811185901028151114735112610584
Horiz.Length
A
171/2171/2171/2171/21919
171/2191919
201/2201/21922
201/219
201/222
CFloor
to Return Conn.
21/221/221/221/221/221/221/221/221/221/233333
21/233
DHot Water
OutletConn.
111111111111111111
E
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
Commercial Large Volume 160/161Unjacketed Storage Tank Models
64567572076579084010401340182021052395270031153530404541205695
N†645N*5AN†675N*5AN†720N*5AN†765N*5AN†790N*5AN†840N*5AN†1040N*5AN†1340N*5AN†1820N*5AN†2105N*5AN†2395N*5AN†2700N*5AN†3115N*5AN†3530N*5AN†4050N*5AN†4120N*5AN†5695N*5A
121100133112143124145153168192216174198222192256262
9471173103113011101142816522182311035163922385143384825600955167994
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
4248424842484854606060727272847284
JacketDia.
Actual U.S.Capacity
Gal.70275277484684694011281457198322762570296133843807446244066141
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height1179612910813912014114716818621016819221693250256
Horiz.Length
A B C D E
201/222
201/222
201/22222
251/2272727303030333033
Floorto Return
Conn.33333333333333333
Hot WaterOutletConn.
1111111
11/211/211/211/211/211/211/211/211/211/2
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
Example of full model number when ordering (NV175NG5A)
* = Tank Lining/ConstructionG = Vitraglas®
D = Double Vitraglas®
E = EpoxyS = Stainless Steel
† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.
Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining
Commercial Large Volume 162/163Vertical Topcoat Storage Tank Models
■ ASME construction■ Bradford White tanks with sprayed-on rigid insulation with acrylic topcoat exceeds ASHRAE 90.1
requirements with 2.25" of high-density polyurethane foam with an “R” value of R-16. SPF meetsrequirements for California Title 24. Bradford White spray foam insulation has the best fire spread ratingwith a class I foam with less than a 25-flame spread rating suitable for boiler room applications.
■ The 100% acrylic topcoat is formulated for applications over spray polyurethane foam and is designed towithstand extreme weather and a full range of environmental conditions.
■ The two component polyurethane foam is applied at ambient temperatures, directly to the vessel in thedesired thickness. The 2-coat topcoat is then applied from a high-pressure spray gun and allowed to drybetween applications.
■ Alternative for insulated and steel jacket■ Any tank size or shape can be insulated■ Field repairable
A
C
B
E
E
Spray Polyurethane Foam: Specific Gravity: 1.17 – 1.19Viscosity: 800 – 1300Density: @ 2" 2.10 – 2.35
@ 4" 1.88 – 1.99Closed Cell Content: >90%K-Factor, initial: 0.155 – 0.170Permeance: 2.91 (perms)
2.99 (perm inch)Dimensional Stability: +3.3 to +8.2 - Dry Age 28 days (158°F, Dry)
-0.37 to –0.96 – Freeze 14 day (-20°F)Flame Spread: 25 - ASTM E-84Smoke Development: 450R Value: 7.2/ inch Max. Thickness: 4"
Acrylic Coating: Topcoat: 2 coats white, 25 milsTexture: SmoothGrade: Spray or RollBase: 100% AcrylicSolids by weight: 66% (+/-3) Solids by volume: 55% (+/-3)Weight per gallon: 11.65 (+/-.2)Tensile Strength: 300 psi (+/-25)Elongation: 260% (+/-25)Durometer hardness: 62 Shore A (+/-2)Tear Resistance: 85 lbs/ in.Permeance: 11 U.S. Perms @ 20 milsViscosity: 110 K.U. (+/-8)Codes/ Approvals: Energy Star, ICC, UL, ASTM D6083Reflectivity: New 85%, Aged 78%Emmisivity: .89
175210240280285310320340360415435465500515575580645
N†175T*5AN†210T*5AN†240T*5AN†280T*5AN†285T*5AN†310T*5AN†320T*5AN†340T*5AN†360T*5AN†415T*5AN†435T*5AN†465T*5AN†500T*5AN†515T*5AN†575T*5AN†580T*5AN†645T*5A
69819110576841179196108871207913211190123
3033473834335505274765695596716957439288158631045947
Vertical and Horizontal Energy Saver ModelsDIMENSIONS IN INCHES
3535353541413541354147415341475347
B
JacketDia.
Actual U.S.Capacity
Gal.193229260303318344340375397449486502572555630658702
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height65778710145801138792104831167512810786119
Horiz.Length
A
171/2171/2171/2171/21919
171/2191919
201/2192219
201/222
201/2
CFloor
to Return Conn.
21/221/221/221/221/221/221/221/221/221/2333
21/2333
DHot Water
OutletConn.
11111111111111111
E
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
Commercial Large Volume 164/165Vertical Topcoat Storage Tank Models
67572076579084010401340182023953115353041205695
N†675T*5AN†720T*5AN†765T*5AN†790T*5AN†840T*5AN†1040T*5AN†1340T*5AN†1820T*5AN†2395T*5AN†3115T*5AN†3530T*5AN†4120T*5AN†5695T*5A
102135114145126147153168216198222256262
1173103113011101142816522182311039224338482555167994
Vertical and Horizontal ModelsDIMENSIONS IN INCHES
53475347535359656577777789
B
JacketDia.
Actual U.S.Capacity
Gal.
75277484684694011281457198325703384380744066141
Nominal U.S.Capacity
Gal.Model
NumberVert.
Height
98131110141122143147168210192216250256
Horiz.Length
A
22201/222
201/22222
251/2272730303033
CFloor
to Return Conn.
3333333333333
DHot Water
OutletConn.
111111
11/211/211/211/211/211/211/2
E
DrainValve
Approx. ShippingWeight (lbs)
@125 PSI
* = Tank Lining/ConstructionG = Vitraglas®
D = Double Vitraglas®
E = EpoxyS = Stainless Steel
† = Tank OrientationV = VertcalH = HorizontalSaddles required for horizontal models.Use Bare Tank Diameter for saddle sizes.
Example of full model number when ordering (NV240TG5A)Note: Please be advised that all tank sizes are available for this topcoat process.
Factory Options Include:• Manway (12" by 16")• Hand Hole (4" by 6")• Saddles
• Extra Tappings (1"-4")Sizes must be specifiedwhen ordering
• Flanged Connections(3"-10")
• Stainless Steel construction• 150 psi (add suffix -5)• Hydrojet® HC(add suffix -1)
Manway inspection port is provided as standard equipment on epoxy lining. Options must bespecified when ordering
Ten Year Warranty with Double Vitraglas® LiningOne Year Warranty with Epoxy Lining
*10 year parts warranty on warranty upgrade kit models only. †Limited Residential Heat Exchanger Warranty. ††Heater Body Element Assembly.
Warranty Information 166/167Some states do not allow limitations on warranties. See copy of the Warranty included with the heater.
Limited TankWarranty
Residential Gas ModelsAtmospheric Vent High EF Models.............................................................. 6 or 10 Year 6 or 10 Year*Atmospheric Vent Damper Models ............................................................ 6 or 10 Year 6 or 10 Year*Atmospheric Vent Models .......................................................................... 6 or 10 Year 6 or 10 Year*Atmospheric Vent High Input Models.......................................................... 6 or 10 Year 6 or 10 Year*Direct Vent Models .................................................................................... 6 or 10 Year 6 or 10 Year*Power Vent (TTW®) Models ........................................................................ 6 or 10 Year 6 or 10 Year*Power Direct Vent Models .......................................................................... 6 or 10 Year 6 or 10 Year*Manufactured Home Models ...................................................................... 6 or 10 Year 6 YearUltra Low NOx Atmospheric Vent Damper Models ...................................... 6 or 10 Year 6 or 10 Year*Ultra Low NOx Atmospheric Vent Models.................................................... 6 or 10 Year 6 or 10 Year*Ultra Low NOx Atmospheric High Input Models .......................................... 6 or 10 Year 6 or 10 Year*Ultra Low NOx Power Vent (TTW®) Models ................................................ 6 or 10 Year 6 or 10 Year*Ultra Low NOx Power Direct Vent Models .................................................. 6 or 10 Year 6 or 10 Year*Ultra Low NOx Direct Vent Models.............................................................. 6 or 10 Year 6 or 10 Year*Infiniti Tankless™ Models .......................................................................... 12 Year† 5 YearResidential Electric ModelsAeroTherm™ Series Heat Pump Models .................................................... 10 Year 10 YearUpright and Lowboy Models ...................................................................... 6 or 10 Year 6 or 10 YearWall Hung and Utility Models .................................................................... 6 or 10 Year 6 or 10 YearPowerful Compact® Models........................................................................ 6 or 10 Year 6 or 10 YearKwickshot® Tankless Models...................................................................... 10 Year†† 1 Year
Commercial Gas ModelsLight Duty Atmospheric Vent High Input Models ...................................... 3 year 1 YearLight Duty Power Vent (TTW®) Models .................................................... 3 year 1 YearLight Duty Power Direct Vent Models ...................................................... 3 year 1 YearLight Duty Direct Vent Models.................................................................. 3 year 1 YearLight Duty Ultra Low NOx Atmospheric Vent High Input Models................ 3 year 1 YearLight Duty Ultra Low NOx Direct Vent Models .......................................... 3 year 1 YearLight Duty Ultra Low NOx Power Vent (TTW®) Models .............................. 3 year 1 YearLight Duty Ultra Low NOx Power Direct Vent Models................................ 3 year 1 YearCommander Series™ Atmospheric Vent Models ...................................... 3 year 1 YearElectronic Ignition Flue Damper Models .................................................. 3 year 1 YearInduced Draft Models .............................................................................. 3 year 1 YearMillivolt Models ...................................................................................... 3 year 1 YeareF Series® Ultra High Efficiency Models .................................................. 3 year 1 YearCommercial Electric ModelsLight Duty Upright and Lowboy Models .................................................. 3 year 1 YearLight Duty Wall Hung and Utility Models .................................................. 3 year 1 YearMedium Duty Models .............................................................................. 3 year 1 YearHeavy Duty Models.................................................................................. 3 year 1 YearASME Models .......................................................................................... 3 year 1 YearBrute Models .......................................................................................... 3 year 1 YearCommercial Storage TankJacketed Storage Tank Models ................................................................ 3 year 1 YearLarge Volume Jacketed Storage Tank Models .......................................... 3 year 1 YearLarge Volume Unjacketed Storage Tank Models ...................................... 3 year 1 YearLarge Volume Vertical Topcoat Storage Tank Models................................ 3 year 1 Year
Limited PartsWarranty
Limited TankWarranty
Limited PartsWarranty
S = 1998 T = 1999 W = 2000 X = 2001 Y = 2002
Z = 2003 A = 2004 B = 2005 C = 2006 D = 2007
E = 2008 F = 2009 G = 2010 H = 2011 J = 2012
K = 2013L = 2014M = 2015N = 2016
K = 1993 L = 1994 M = 1995N = 1996 P = 1997
Tank Type Serial Number IdentificationFIRST LETTER - YEAR OF MANUFACTURE
A = JANUARYB = FEBRUARYC = MARCHD = APRIL
Example:FC12345678 = MARCH, 2009 ProductionNA12345678 = JANUARY, 1996 Production
Bradford White uses a 20-year letter designation rotation in serial numbers. Therefore, please be aware that water heaters manufactured 20 years apart will have the same serial number “letter year” designation.(i.e. A = 2004 and 1984).
E = MAYF = JUNEG = JULYH = AUGUST
J = SEPTEMBERK = OCTOBERL = NOVEMBERM = DECEMBER
SECOND LETTER - MONTH OF MANUFACTURE
FPC-0815© 2015, Bradford White Corporation. All Rights Reserved.
Visit us on the web at: www.bradfordwhite.comSales/800-523-2931 • Fax/215-641-1670
Technical Support: 800-334-3393 • email: [email protected] • Fax: 269-795-1089Warranty: 800-531-2111 • email: [email protected] • Fax: 269-795-1089
Ambler, PA
Bradford White Corporation Subsidiary Companies
Built to be the Best™