t669 life sciences bro 5 - your partner for pressure ...€¦ · invensys eurotherm invensys...
TRANSCRIPT
imagine making the impossible possible
ProductSelection Guide
Invensys EurothermInvensys Eurotherm is aleading global supplier ofcontrol, measurementand data recordingsolutions and services toindustrial and processcustomers. Thecompany’s internationalreputation as a providerof innovative solutionsacross a broad spectrumof vertical markets issupported byengineering servicesdesigned to realisegreater benefits tocustomers’ plant-wideassets. InvensysEurotherm is a keybusiness within InvensysOperations Management,a global technology,software and consultingorganisation leadingsignificant change inprocess manufacturing,plant optimisation,business operations andenterprise performance.
Add to this, an absolutecommitment totechnological innovation,constant reinvestment inresearch anddevelopment, and a teamof engineering orientedsalesmen whounderstand your processrequirements; we canand do imagine makingthe impossible possiblefor our customers.
Recorders and DataManagement
Solid StateRelays/SCR PowerControllers
Plastics Machine ControlSystems
Machine Control andProgrammableAutomation Control
Service and Support
I/O Signal Conditioning,Probes, Thermosensors and Actuators
PID controllers, Indicator and Alarm Units
Selection G
uide C
ontents
Simply imagine process excellence and with Eurotherm you will achieve it. Our range of controllers provide worldclass control and versatility with clear, user friendly, operator interfaces.
• Single Loop Controllers • Multi Loop Controllers • Indicators • Alarm Units • Software •
With our range of recorders and software, your data is stored very easily; imagine absolute data records forever.We can securely archive your vital data to multiple locations with flexible reporting enabling you to retrieveinformation when and where you need it.
• Paperless/Graphic • Paper • Software •
Our formidable range of power products cover all types of load and voltage but imagine having the power to saveenergy. With many features like high performance alarm strategies and advanced diagnostic load fault detection,Eurotherm is the only choice for your power control applications.
• Solid State Relays • SCR Power Controllers •
Imagine taking full control of the process our MACO® control systems are specifically designed to save plasticOEMs and producers time and money. They are based on a revolutionary building block architecture that isdesigned to adapt to the ever changing needs of the plastics industry. The result is an open and scalable systemthat contains four decades of injection, extrusion and blow molding knowledge.
• MACO Control Systems • Operator Stations •
Can you imagine one expert in process automation and data management? Our process automation solutions arescalable from the smallest HMI application to the largest enterprise automation network and by using a consistenttoolset provide the flexibility and scalability needed to engineer these solutions in a cost effective way.
• Foxboro Software • Foxboro PAC System Hardware •
We understand signal conditioning and isolation. Just imagine high performance,reliability and ruggedness. Ourproducts are built to survive the extremes of vibration,shock, temperature and humidity,and are designed for easyinstallation, operation and maintenance.
• I/O Signal Conditioning • Carbon/Oxygen Probes, Thermosensors, Ancillary • Valve Actuators • Sensors •
Modern processes require precise control to maximize quality output for minimum cost - Imagine services thatsupport maintain and enhance your process during the product life cycle.
Our support solutions offer you the option of a broad range of customized services designed to reduce your costof ownership, lower your inventory costs and uncertainties associated with managing your maintenance operation.Our aim is to work as an active partner in your business. Working with you, our support and field service teams areexperienced group of engineers, backed by specialists across Invensys Eurotherm to protect your investment. Theywill ensure your operation is optimized and runs efficiently.
• Technical Support • Installation and Commissioning • Training • Repair and Support Services • • Engineering Services • Field Services •
Product Range
Features
Panel size (DIN)
IP Rating
Single Loop
Display Type
Supply Voltage
Input Type
PV Accuracy
Control Types
SP Programmer
Analogue IP/OP
Digital IP/OP
Digital Comms
Alarm Types
PC Configuration
Special Features
Maths Equation
Combinational Logic
Timers/Counters/Totals
Real Time Clock
2216e 2208e
1/16DIN rail
1/8
IP65
2200
2204e
1/4
TC, RTD, mV, mA, Volts
2 x 4 dig LED
none
none
none
none
<0.25%
On/Off. PID, VP
none
none
In: 1 Out: 1
In: 3 Out: 4
Modbus, DeviceNet
List based
85-264V ac
Hi, Lo, Dev, Sensor break,
Event, Heater fail
none
none
none
none
Dual input control
Hi, Lo, Dev, Sensor break,
Event, Heater fail
2416 2408 2404
1/16 1/8 1/4
IP65
2400
TC, RTD, mV,mA, Volts
2 x 4 dig LED
<0.2%
On/Off. PID, VP
20 x 16 segments
In: 2 Out: 3
In: 11 Out: 11
List based
24V dc/ac85-264V ac
Modbus, DeviceNet, Profibus
1/32
IP65
2100
TC, RTD, mV, mA, V
1 x 4 dig LED
<0.25%
On/Off. PID
none
In: 1 Out: 0
In: 1 Out: 2
none
none
none
none
none
List based
none
24V dc/ac85-264V ac
2132
Hi, Lo, Dev, Sensor break,
1/8
3500
3508 3504
1/4
Graphical Wiring
In: 5 Out: 6
In: 40 Out: 41
Modbus, DeviceNet, Profibus, Ethernet
On/Off, PID, VP
IP65
Main PV: 5 digit plus 4 line alphanumeric
TC, RTD, mV,mA, Volts
<0.1%
50 Programmes, 500 Segments max
24V dc/ac, 85-264V ac
User wiring,Master comms
Hi, Lo, Dev, Sensor break,
Event, Heater fail
24 Calculations
24 Operations
4 / 2 / 2
Day and Time
none
none
none
none
3208 32043216
1/16
IP65
3200
1/8 1/4
TC, RTD,mV,mA, CT
Main: 4 digits Lower: 5 character starburst (3216/08/04) 9 character starburst (32h8)
<0.25%
24V dc/ac85-264V ac
On/Off. PID, VP
Recipes, Text messaging
4 Ramp + 4 Dwell
In: 2 Out: 3
In: 3 Out: 4
Modbus
Hi, Lo, Dev, Sensor break,
Event, Heater fail
Wizard
32h8
1/8
Safety Approvals none EN14597 TR nonenonenone
Features
Panel size (DIN)
IP Rating
Display Type
Input Type
Supply Voltage
PV Accuracy
Control Types
Control Loops
Control Algorithms
Special Features
SP Programmer
Analogue IP/OP
Digital IP/OP
Digital Comms
Maths Equation
Combinational LogicTimers/Counters/Totals
Real Time Clock
PC Configuration
2604Multi Loop 2704
2704
Dot Matrix
Melt Pressure,Carbon Potential, Vacuum, Humidity
Modbus, DeviceNet, Profibus, Ethernet
32 Calculations
60 Programmes, 600 segments max
2604
2 x 5 dig LED+ 2 line text
Melt Pressure, Carbon Potential,
Humidity, User wiring,Master comms
Modbus, DeviceNet, Profibus
24 Calculations
50 Programmes, 500 segments max
3504
1/4
3508
1/8
Alarm Types
1/4
IP65
TC, RTD, mV, mA, Volts
<0.1%
On/Off, PID, VP
3
Single, Ratio, Cascade, OverrideSingle, Ratio, Override
In: 8 Out: 8
In: 44 Out: 43
32 Operations
4 / 0 / 4
Day and Time
Graphical Wiring
24V dc/ac, 85-264V ac
Hi, Lo, Dev, Event, Heater fail
3500
Graphical Wiring
24 Calculations
24 Operations
4 / 2 / 2
Day and Time
In: 5 Out: 6
In: 40 Out: 41
Modbus, DeviceNet, Profibus, Ethernet
On/Off, PID, VP
2
Carbon Potential, Humidity,Melt Pressure, User wiring,
Master comms
IP65
Main PV: 5 digit plus 4 line alphanumeric
TC, RTD, mV, mA, Volts
<0.1%
50 Programmes, 500 segments max
24V dc/ac, 85-264V ac
Hi, Lo, Dev, Sensor break,
Event, Heater fail
Mini8™Controller
Mini8
DIN rail
IP20
Remote
TC, mV, RTD, mA, CT
<0.1%On/Off, PID
16
Single
Humidity, Load diagnostics,
User wiring
8 Programmes, 16 segments each
In: 32 Out: 8
In: 34 Out: 32
Modbus, DeviceNet, Profibus, Modbus TCP/IP
EtherNet/IP Server
24 Calculations
24 Operations
4 / 2 / 2
Day and Time
Graphical Wiring
24V dc
Hi, Lo, Dev, Sensor break,
Event, Heater fail
nanodac
On/Off, PID, VP
2
3.5” TFT colour 320 x 240 pixels
nanodac™Controller
IP65
1/4
TC, RTD,mV, mA
<0.1%
100-230V ac
In: 8 Out: 3
In: 4 Out: 5
Modbus TCP/IP Master/SlaveEtherNet/IP Client/Server,
Graphical Wiring
Hi, Lo, Dev
Day and Time
4 / 15 / 1524 Operations
17 Calculations
Relative Humidity,Washdown Faceplate,
User Wires,Carbon Potential
100 Programmes, 25 segments Local/USB/FP
Cascade
PID Controllers, Indicators and Alarm Units
PID
Cont
rolle
rs, I
ndic
ators
and
Ala
rm U
nits
Panel size (DIN)
IP Rating
Display Type
Supply Voltage
Safety Approvals
Input Types
User Calibration
PV Input Selection
No of Alarms
Alarm Types
No of Relay Outputs
Custom Messages
Slave Comms
Melt Pressure
Transducer PSU
Transmitter PSU
none
none
none
none none
4 4
128 Characters 128 Characters
3 2
Modbus RTU Modbus RTU
10V dc
24V dc
Hi, Lo, Dev, Sensor break, Rate of change
Hi, Lo, Dev, Sensor break, Rate of change
Hi, Lo, Dev, Sensor break, Rate of change
5 point 5 point, Shunt, Load cell,Auto tare
2132i
1/32
none
none
none
none
none
none
none
3
2
TC, RTD, mV, mA,Custom
Hi, Lo, Dev, Sensor break
IP65
2 point
4 Digit LED
100-264V ac, 24V ac/dc
3216i
1/16
TC, RTD, mV, mA,Custom
TC, RTD, mV, mA,Volts, Custom, Strain gauge
IP65
4 Digit LCD plus 5character alphanumeric
EN14597/TW, FM EN14597/TW, FM
32h8i
1/8
IP65
5 Digit LCD plus 9character alphanumeric
100-264V ac, 24V ac/dc
2100Indicators andAlarm Units
3200 2400
none
none
none
4
128 Characters
2
24V dc
Modbus RTU
5 point
TC, RTD, mV, mA,Custom
EN14597/TW, FM
3204i
1/4
IP65
4 Digit LCDplus 5 characteralphanumeric
100-264V ac, 24V ac/dc 100-264V ac, 24V ac/dc
none
8
Digital IP/Logic OP 2/0 2/01/2 2/0 2 plus possible further 9/9
7
24V dc
5/10V dc
Modbus RTU, DeviceNet,Profibus DP
Hi, Lo, Dev, Sensor break,Rate of change, Event
15 point, Shunt, Load cell,Comparison, Auto tare
Hi, Lo, Select, Switchover,Derived
TC, RTD, mV, mA,Volts, Custom
2408i
1/8
IP65
Large 5 Digit LED
100-264V ac, 24V ac/dc
Retransmission Non isolatednone Isolated Isolated Isolated
none
Features
List based List basedPC Configuration Graphical Wiring Graphical Wiring Graphical Wiring
Software Configuration Tools
iTools
PenGUIn Software
GUIcon
Features
Display Type
Keypad
Resolution
USB and Host USB
Ethernet
Comms Ports
PenGUInmachine-HMI
PG6 PG8
320 x 240 pixels
Two RS-232, two RS-422/485(expandable) Isolated ports
Yes
YesYes (host only) Yes Yes
YesYes Yes Yes
CompactFlash Slot
Power Supply
Dimensions
Protocol Conversion
Optional Cards
Web/FTP Server
Data Logging
Software
Certificates
Ratings
7.08" x 8.83" x 2.3"(179.8 x 224.3 x 58 mm)
8.18" x 10.32" x 2.9"(207.8 x 262 x 73 mm)
9.50" x 12.83" x 2.45"(241.3 x 325.8 x 62 mm)
13.0"x 16.0" x 2.8" (330.2 x 406.4 x 71.5 mm)
5.7" TFT Active Matrix,256-color QVGA display
Programmable 5-keymembrane
640 x 480 pixels
8.4" TFT 32K-color
Programmable 7-keymembrane
640 x 480 pixels
10.4" TFT 32K-color VGA display
Programmable 8-keymembrane
1024 X 768 pixels
32K Color XGA LCD display
Programmable 10-keymembrane
Two RS-232, one RS-422/485 standard; expandable with optional card
10 Base-T/100 Base-TX
Modem
NEMA 4X/IP66
UL Class I, Div 2
User-programmable logging rates with time/date stamp and security management; data synchronization, PLC and alarm triggering; CSV file format
Remote access and control, access to logged data via FTP or web browser; pass-throughprogramming; notification and alarms; automatic HTML page population
Free GUIcon software with free upgrades and support; drag-and-drop data mapping, free device drivers, milti-language support 5000+ graphics library
24V dc ±20%
PG10 PG15Options
MiniEM3
Multi-zone Plastic Extrusion Solution
Heating only with current monitoring
Heating only
Heating and Coolingwith current monitoring
The MiniEM3utilizes the
Mini8 Controllerand the PenGUIn Panel
(from PG8 Upwards)Upto 24 high accurate(using multiple Mini8)
heat control zones can be controlled
Heating and Cooling
PID Controllers, Indicators and Alarm Units
PID
Contro
llers, Indicato
rs and A
larm U
nits
Paperless/Graphic
Features
Inputs
Graphic Display
Relay Outputs
Annotation
Digital Comms
Batch
Auditor Features
Ethernet/FTP
Custom Screens
Remote Viewing
Mathematics
Counters
Totalisers
PC Configuration
Contact Inputs
Timers
Paperless Graphic Recorders
Webserver
Trend Speed
Network Addressing
Groups
Review of History (on screen)
AMS2750E (input accuracy)
Protection
USB
nanodac™Recorder
3.5” TFT320 x 240 pixels
DHCP,Fixed IP
8Hz
none
none
none
none
none
IP65
4
11
Modbus TCP/IP Master/SlaveEtherNet/IP Client/Server
nanodac 6100A
18
5.5"
6180A
48
12.1"
DHCP,Boot P
Fixed IP
8Hz
312
Modbus TCP/IPMaster/Slave
EtherNet/IP Server
IP66
6180XIO
12.1"
none
6100XIO
5.5"
none
DHCP,Boot P
Fixed IP
none
none
Modbus TCP/IPMaster/Slave
EtherNet/IP Server
8Hz
112
IP65
DHCP,Boot P
Fixed IP
none
none
none
none
6100E
6
5.5"
1Hz
11
Modbus TCP/IP Slave
IP66
6100A
15
5.5"
6180A
30
12.1"
none
none
DHCP,Boot P
Fixed IP
Recording Speed 8Hz 8Hz 8Hz 1Hz 8Hz
8Hz
312
Modbus TCP/IPMaster/Slave
EtherNet/IP Server
IP66
Portable TUS Recorders
Recorders and Data Management
MODBUS SLAVEINDUSTRy STANDARD PLC
6180XIO
24004103C
3208
6100A
3504
HUB
2704
MINI8CONTROLLER
BRIDGE
REVIEW
FTPSERVER
MODBUS TCP and RTU MASTER
ETHERNET/IP MASTERINDUSTRy STANDARD PLC
MODBUS SLAVES
MODBUS TCP/IP
ETHERNET/IP
SERIAL MODBUS RTU (PORT 2)
SERIAL MODBUS RTU (PORT 1)
MODBUS TCP/IP
FTP
FTP
T2750
T2550
Rec
ord
ers
and D
ata
Man
agem
ent
Software
Bridge Eyris™ Software
Visualisation Packages
Review Review QuickChart
TUSDreamReport
Data Reporting & Manipulation
SecurityManager
Applications
Paper
IP54 IP54
100mm 100mm
Slave
392
4
10” circular
none none
none
none
none
none
none
none none
none none
none
Strip Chart Circular
none
none
none
Inputs
Chart Width
Removable/Data Storage
Relay Outputs
Annotation
Modbus (Serial)
Mathematics
Counters
Totalisers
Controllers
PC Configuration
Contact Inputs
Timers
Features
Protection
4102M4102C
4 6
4103M4103C
4 6
Recorders and Data Management
imagine absolute data records forever
Reco
rders and
Data M
anagem
ent
Heater Type Constant Resistance
SWIR (Short wave infrared)
Logic
Analogue
Zero Crossing
Maximum Current (Amps)
Maximum Voltage (Volts)
Controlled Phases
Input
Firing Mode
PLF and/or PLU
Diagnostics
Alarms
Digital Communications
Single PhaseSolid State Contactors (SSCs) Multi Phase
Features 7100L
none
100A
500V
1
none
none
none
TE200S
63A
2
none
none
none
none
TC2000
500A
2
none none
7100S
250A
Modbus ModbusModbus
1
7200S
2
200A
7300S
160A
3
TE10S
50A
500V 500V500V 500V 500V500V
1
none none
none
none none
DIN Rail Solid State RelaysSolid State RelaysSolid State Relays (SSRs) I/O Series
3
25A
600V
RVD3RVA3RVM3
RVDARVAARVMA
RSDARSAA Input Module Output Module
none
none
none
none
1
40A
600V
none
none
none
1
100A
600V
none
none none none
none
1
100mA
28V
none
none
none
none
none
none
1
3A
60V dc/250V ac
SVDASVAA SVDD
none
none
1
75A
600V
none
none
none
none
1
40A
100V
none
none
none
none
none
none
none
none
none
none
none
none
none
Heater Type Constant Resistance
Analogue
Logic ac
Logic dc
Zero Crossing
Burst Firing
Inductive/Coil
Dc Output
AC Output
Maximum Current (Amps)
Maximum Voltage (Volts)
Integrated Heatsink
Controlled Phases
Input
Firing Mode
Built-in Fuse
Overtemperature Alarm
CE Compliant
UL/CSA
Features
Solid State Relays/SCR Power Controllers
Solid
Sta
te R
elay
s/SC
R P
ow
er C
ont
rolle
rs
Constant Resistance
SWIR (Short wave infrared)
Variable Resistance
True Power Control
Single PhasePower Control Multi Phase
Digital Communications
TE10A
none
50A
1
none
none
none
none
500V
63A
1
500V
TE10P
80A
1
500V
TE300
3
none
none
none
none
none
none
63A
none
none
none
500V
none
none
none
none
none
none
TE200A
2
63A
none
none
none
500V
none
7200A
2
200A
none
none
none
none
none
500V
7300A
160A
ModbusProfibus,Modbus
Modbus TCP
3
500V
7100A
250A
500V
1
none
Heater Type
Analogue
Logic
Phase Angle
Burst Firing
Inductive/Transformer Coupled
Maximum Current (Amps)
Controlled Phases
Input
Firing Mode
PLF and/or PLU
Current Limit
Diagnostics
Alarms
Features EPower Controller EPack
Power Controller
1-4 x 1, 1-2 x 2 or 3
690V
Standard 50-630AHigh current 800-4000A
Profibus, EtherNet/IP,CC-Link, DeviceNet,
Modbus, Modbus TCP, ProfiNet
PC Configuration none nonenonenonenoneGraphical Wiring nonenoneGraphical Wiring
Maximum Voltage (Volts)
Solid State Relays/SCR Power Controllers
imagine having the power to save energy
Solid
State Relays/SC
R Po
wer C
ontro
llers
Features
Display TypeDisplay Type
DescriptionDescription Custom4, 5 & 6
Custom40 & 50
MACO 4000, 5000
& 6000
MACO 4500, 5500
& 6500
MACOASB
MACORS
MACOSRS
Alpha Systems
DS1x
ASB/RS/SRS SystemsMACO ControlSystems
DS8x DS4x 47x0
nonenone none none none none none
6Cxx 6xxx
4-slotenclosed
Pixel SizePixel Size
ChassisChassis
ApprovalsApprovals
Host CommsHost Comms
IO BUSIO BUS
OptionsOptions
cULus CE, cULus
7-slotopen
9-slotopen
12-slotopen
16-slotenclosed
4-slotopen or
enclosed
8-slotopen
Applicationspecificblock(ASB)
CE, cULus cULus
Modbus Plus,Modbus TCP/IP
Modbus PlusModbus TCP/IP,
RS485
Modbus Plus, Modbus TCP/IP,
RS232/485 Modbus RTU, Profibus,
Interbus S, DeviceNet
RS485, SPI,
Modbus RS485 RTU
RS485 MACOnet
nonenone none none none none none
nonenone nonenonenonenone
Features
Display TypeDisplay Type
DescriptionDescription
Pixel SizePixel Size
CE, cTUVus,IP54
CE, cTUVus,IP54
CE, cTUVusin process
CE, cTUVusin process
1024 x 768 1024 x 768 1024 x 768 1024 x 768
PC based operator stations
ApprovalsApprovals
Host CommsHost Comms
OptionsOptions none none
OPtima/Lite OPtima Touch PCs
12.1” TFTcolor LCD
touch-screen XVGA
15” TFTcolor LCD
touch-screen XVGA
12.1” TFT color LCD
touch-screen XVGA
15” TFT color LCD
touch-screen XVGA
CE, cULus
none none
41AC
10.4” TFT color VGA
640 x 480
OperatorStations
RS485 MACOnet Modbus Plus, Modbus TCP/IP
Compact Systems
Breeze IIcParisonControl
CE, cULus
Ethernet Modbus TCP/IP
Ethernet Modbus TCP/IP
ControlSystem
MC4C
none
4-slotenclosed
Modbus TCP/IP
none
6 or 8slot open
OperatorStation
MCD2
12.1” TFT color LCD
touch-screenCE.net SVGA
800 x 600
PC basedWW
InTouch
none
ExtrusionControl
EM-3c
12.1” TFT color LCD
touch-screenCE.net SVGA
4-slotenclosed
800 x 600
PC basedWW
InTouch
MCJ
12.1” TFT color LCD
touch-screenCE.net SVGA
Modbus PlusEthernet Modbus
TCP/IP, RS485
PC basedWW
InTouch
Cards builtin display
800 x 600
49x0
Primary Modbus TCP/IP,
Modbus Plus,Can Bus Open,
RS232/485 Modbus RTU,
Profibus, Interbus S, DeviceNet
Primary Modbus TCP/IP,
Modbus Plus,Can Bus Open,
RS232/485 Modbus RTU,
Profibus, Interbus S, DeviceNet
DSD8 DSE8 PCD8 PCE8
Dedicated operator station
Swing arm pushbutton enclosure
imagine taking full control of the process
Plastics Machine Control Systems
Pla
stic
s M
achi
ne C
ont
rol S
yste
ms
Project Studio/Developer
Foxboro PACSoftware
Configuration Tools
Process Viewer Operations Server Operations Viewer
Visualisation Packages
InformationManager
WonderwareActiveFactory™
Dream Report™Software
Data Reporting & Manipulation
SecurityManager
ControlModules
ApplicationModules
Applications
OPC Server
Network Support& I/O Drivers
Features
Display Type
IP Rating
Input Type
Analogue IP/OP
Batch
Recipe
Auditor Features
Control
SP Programmer
Modbus (Serial & TCP)
Digital IP/OP
Network Addressing
Ethernet (ELIN)
Foxboro PACSystem Hardware
Eycon™ VisualSupervisor
OPtima TouchPAC
Data Logging
8 Channels, 40 Segments each 8 Channels, 32 Segments each
Eycon 10 OPtima Intouch PCEycon 20
5.5” QVGA
IP65 IP65
12.1” XGA 12.1”XVGA
15”XVGA
Remote
Remote
Remote
Remote
Yes
Yes
Yes
Yes
Yes Yes
10/100Mbps 10/100Mbps 10/100Mbps
Master/Slave Master/Slave
DHCP, Boot P, Link Local, Fixed
DHCP, Boot P, Link Local, Fixed
T2750 T2550
IP20
Remote
mV, V, mA, T/C,RTD, Potentiometer
In: 64 Out: 32
Yes
Yes
Yes
In/Out: 256 In/Out: 128
none
none
none
none
none
none
none
none
none
Yes
Yes
Profibus Master SlaveNo No
Machine Control and Programmable Automation Control
imagine one expert in process automation
and data management
Machine C
ontro
l and Pro
gram
mab
le Auto
matio
n Contro
l
-STD: 0-115200 baud, all character formats
-ADE/PROG: 30-115200 baud,n/e/o/ parity,7/8 data bits,
1/2 stop bits
Interface: Standard productPort 1 is RS232
Port 2 is RS422/485Any combination of
RS232, 422/485
FeaturesUltra SlimPak II – High
Accuracy & Ethernet ready
Input Types
Output Types
DC Volts/Current,RTD, mV,
Thermocouple,Potentiometer,Strain Gauge,
AC Volts/Current,Frequency
0-10V dc,0-20mA dc,
4-20mA dc or2 SPDT relays
Isolation 1800VInput/Output/
Power
Power 9-30V dc via Terminals or jumpers
Mounting High densityDIN rail
Wiring Removableterminals
Special Features Smart power,Ethernet
communications
ASIC reliability
Calibration via TouchCal
UltraSlimPak –Basic, Low Cost
DC Volts/Current,RTD, mV,
Thermocouple,Potentiometer,Strain Gauge,
AC Volts/Current,Frequency
0-5V dc,0-10V dc,0-1mA dc,
0-20mA dc,4-20mA dc or2 SPDT relays
1800VInput/Output/
Power
9-30V dcG448 18-30V
High densityDIN rail
Fixedterminals
Removableterminals
Removableterminals
Removableterminals
Fixed terminals Fixed terminals
Potentiometer,G478 TouchCal
Action I/Q(AC Powered)
DC Volts/Current,RTD, mV,
Thermocouple,Potentiometer,Strain Gauge,
AC Volts/Current,Frequency
0-5V dc,0-10V dc,0-1mA dc,
0-20mA dc,4-20mA dc or2 SPDT relays
1800VInput/Output/
Power
85-265V ac
IQRL power buson DIN rail
2 ch versions,Signal splitters,
Field configurable I/P type versions
TouchCal
Action I/Q(DC Powered)
DC Volts/Current,RTD, mV,
Thermocouple,Potentiometer,Strain Gauge,
AC Volts/Current,Frequency
0-5V dc,0-10V dc,0-1mA dc,
0-20mA dc,4-20mA dc,
Frequency, or2 SPDT relay(s)
0-5V dc,0-10V dc,0-1mA dc,
0-20mA dc,4-20mA dc,
Frequency, or2 SPDT relay(s)
1800VInput/Output/
Power
Various powerProduct dependant
9-30V dc18-30V dc
10.8-26.4V dc
DIN rail orIQRL power bus
2 ch versions,Signal splitter,
Math functions,Field configurable
I/P type versions
TouchCal
Action I/Q(Loop Powered)
ActionPak
DC Volts/Current,RTD, mV,
Thermocouple
4-20mA dc
1800VInput/Output andchannel/channel
10-35V ac
DIN rail Plug-in (8 or 11 pin)
Multi channelversions
Potentiometer
Action InstrumentsI/O SignalConditioning
FeaturesIn-Situ
Carbon Probe – AP1ACP
Carbon Probe MEMOCAL 2000
Universal IsolatedInterface Converter –
KD485
Output 1.00-2.00V dc 0 to 1250mV dc mA, V, TC, RTD
Multi function LCD
Battery
0.015% of span
Type B, E, J, K, L, N, R, S, T, U, W, W3, W5, PLII
EIA232
Hand held
Remote programmingData recording
EIA232 commsDesk top adapter
(with EIA485 comms)
% carbon probe into 8MΩ 0.01 to 1.6 % Carbon % oxygen *
+7 - +35V dc
±0.05 weight % carbon innormal operating range
+/-0.05 weight % carbonin normal operating range
2 Asynchronous ports,TX & RX signals only
DIN Rail
Less than 1.0 second Less than 1.0 second
Readout
Accuracy
Response Time
Power Supply
Power Consumption
Isolation
Mounting
Thermocouple
Ports
Port Parameters
Options
ProbesProbesThermosensorsAncillary(Other)
Ancillary
Type K, R & S Type K, N, R, S
2000V ac
Quick DisconnectConnectors available for
Eurotherm, FCC andMMI probes
n/a
n/a
n/a
n/an/a
n/an/a n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/an/a
n/a
n/a
n/a
n/a
n/an/a
n/a
TransPak
DC Volts/Current,RTD, mV
Thermocouple,Potentiometer,
AC Volts/Current,
Frequency
DC Volts/Current,RTD, mV,
Thermocouple,Potentiometer,Strain Gauge,
AC Volts/Current,Frequency
4-20mA dc
Varies withproduct
Up to 1500Vdepending on model
Varies byModel
9-30V dc, 120V ac or 240V ac
Field mounthousing or head
or DIN rail
Optional display,HART,
2 I/P channels with math
The most diverseinput/output
range
Potentiometeror software
* Sensors should be used with controlling, recording and indicatinginstruments having an input impedance of 10 meg ohms or higher.
I/O Signal Conditioning, Probes, Thermosensors and Actuators
I/O
Sig
nal C
ond
itio
ning
, Pro
bes
, The
rmose
nsors
and
Act
uato
rs
Auxiliary Swicthes
Features EA01/EA02 EA12 EA20 Series EA40 Series EA50 Series EA60 Series EA70 SeriesEA31
Output Types
4-20mA Input
24V ac 50-60Hz120V ac 50-60Hz240V ac 50-60Hz
SelectedModels
SelectedModels
150-300lb-in 60lb-in 50lb-in 220lb-in 50lb-in 60-220lb-in 450lb-in 550-1300lb-in
No NoOptional Optional Optional Optional Optional
120V ac 60Hz240V ac 50Hz
24V ac 60Hz120V ac 60Hz240V ac 60Hz
120V ac 60Hz240V ac 60Hz240V ac 50Hz
120V ac 50-60Hz 120V ac 60Hz120V ac 50Hz
24V ac 60Hz120V dc 60Hz120V ac 50Hz240V ac 60Hz
24V ac 60Hz120V ac 60Hz240V ac 60Hz
No 1 Optional 1 Standardadditional
2 or 4switchesoptional
1 Standardadditional
2 or 4switchesoptional
1 Standardadditional
2 or 4switchesoptional
1 Standardadditional
2 or 4switchesoptional
1 Standardadditional
2 or 4switchesoptional
1 Standardadditional
2 or 4switchesoptional
Position Signal No No Potentiometeroptional
Potentiometeroptional
Potentiometeroptional
Potentiometeroptional
Potentiometeroptional
Potentiometeroptional
90° Stroke
180° Stroke
360° Stroke
UL Listed
CUL or CSA
CE
Linear Stroke
Torque
NEMA 4 NEMA 1 NEMA 4(SelectedModels)
NEMA 4(SelectedModels)
NEMA 3(SelectedModels)
NEMA 4(SelectedModels)
NEMA 4(SelectedModels)
NEMA 4(SelectedModels)
NEMA Rating
nonenone
nonenone
none
none none
none
none
none
none
none
none
none
none
none
none
none none
none none none none
none
none
none nonenone
EA SeriesValve Actuators
I/O Signal Conditioning, Probes, Thermosensors and Actuators
I/O Sig
nal Cond
itioning
, Probes, Therm
osenso
rs and A
ctuators
imagine highperformance, reliability
and ruggedness
Field Services
• Onsite-emergency trouble shooting andrepair
• Process improvement
• Routine maintenance
Technical Support
• Free telephone support via ourdedicated help desk
• 8A-8P coverage
• Extended Warranty
• Service Contracts
— Breakdown: 24Hr cover 7 days a week with guaranteed response to site
— Parts management, included bonded spares placed on site
— Preventative Maintenance and health checks
— Remote Diagnostic Support
— Disaster Recovery Backups and Recovery
• Online web portal for accessingEurotherm’s knowledge base plus onlinetechnical community
Training
• Formal classroom based includingbespoke courses
• Informal hands-on “question & answer”at customer’s site
EngineeringServices
• Design, configuration andimplementation of bespoke systems
• Custom clone files and configuration
• Custom user screens
• Application programming
Installation and Commissioning
• Complete installation andcommissioning of discreteinstrumentation to large DCS systems
• Loop tuning and optimisation
Repair and Support Services
• Repair option
Premium: 24Hr from receipt of module
• Upgrades, calibration, refurbishedequipment for sale
• Complete 1 year warranty
imagine services that support maintain
and enhance your process
Service and Support
Serv
ice
and S
upport
© Copyright Eurotherm Limited 2013
Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris, EPower, EPack, nanodac, piccolo, Foxboro andWonderware are trademarks of Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners.
All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, normay it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the documentrelates, without the prior written permission of Eurotherm Limited.
Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this documentmay therefore be changed without notice. The information in this document is given in good faith, but is intended for guidance only.
Eurotherm Limited will accept no responsibility for any losses arising from errors in this document.
Part No. HA031578 Issue 1 Printed 02.13
Invensys Eurotherm USA Headquarters44621 Guilford Drive, Suite 100Ashburn, VA 20147United States
T +1-703-724-7300F +1-703-724-7301
Worldwide Officeswww.eurotherm.com/global
Represented by:Contact Information
Scan forlocal contacts
Eurotherm: International sales and support www.eurotherm.com