klip-lok 700 brochure 2017-professional - globalroofs.co.za · 2nd. klip-lok 700 sheet 1st....

6
Talk to THE SMART ROOF PEOPLE Visit www.globalroofs.co.za or email [email protected] GRS Klip-Lok 700 GRS Klip-Lok 700 Global Roofing Solutions Klip-Lok 700 TM GRS Klip-Lok 700 07/17

Upload: others

Post on 30-May-2020

32 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Klip-Lok 700 Brochure 2017-professional - globalroofs.co.za · 2nd. Klip-Lok 700 Sheet 1st. Klip-Lok 700 Sheet Purlin Klip-Lok 700 Profile Note Fasteners must be selected to match

Talk to THE SMART ROOF PEOPLEVisit www.globalroofs.co.za or [email protected]

GRS Klip-Lok 700

GRS Klip-Lok 700

Global Roofing SolutionsKlip-Lok 700 TM

GRS Klip-Lok 700 07/17

Page 2: Klip-Lok 700 Brochure 2017-professional - globalroofs.co.za · 2nd. Klip-Lok 700 Sheet 1st. Klip-Lok 700 Sheet Purlin Klip-Lok 700 Profile Note Fasteners must be selected to match

Typical Specification

®

Galvanised Z275

Chromadek Z200

Zincalume AZ150

Clean COLORBOND AZ150 Special

Special

Special

ZincAL AZ150

COLORPLUS AZ150

ISQ 500

G550

G550

®

Material Steel Colour One Side Colour Two Side

®

®

Materials

The roofing shall be Klip-Lok 700 profile, roll-formed in continuous lengths in one of thematerials in the table below. Klip-Lok 700 is obtained from Global Roofing Solutions.

The Profile

The profile is roll-formed from certified steel complying with (select from steel column in above table). The profile shall have 4 trapezoidal ribs at 233mm centres giving a nett cover of 700mm. The male rib shall have spurs to ensure a positive double interlocking action at side-laps. Each pan shall incorporatetwo stiffener ribs.

Assembly

It is recommended that Klip-Lok 700sheeting be laid by an approved contractor instrict accordance with the manufacturer’sspecifications. When using a GRS(Brownbuilt) Approved Contractor, a five yearguarantee on site-workmanship and watertightness may be issued after approval by Global Roofing Solutions.

Flashings

Stop endings must be formed at the apexand the pan turned down at the eaves toform a drip. The roof sheeting shall be closedas necessary with purpose-made flashingsof a design approved by the supplier. Theseflashings shall be notched around ribs, wherenecessary, and fixed on S10 clips. All theseoperations must be performed with specialtools available from the supplier.

Site Handling

Klip-Lok 700 sheets should be suitably supported, clear of the ground, under well ventilated cover, away from risk of damage by building operations, contact with cement,dust, lime and abrasive dust, until installation takes place.

Cleaning Up

The complete roof must be kept clean andfree of any swarf and debris.

Quality Assurance

The manufacturer shall be assessed and certified as complying with ISO 9001:2008Quality Management System.

Translucent Sheeting

The Klip-Lok 700 profile is available inPolycarbonate.

Page 3: Klip-Lok 700 Brochure 2017-professional - globalroofs.co.za · 2nd. Klip-Lok 700 Sheet 1st. Klip-Lok 700 Sheet Purlin Klip-Lok 700 Profile Note Fasteners must be selected to match

Fasteners

The recommended fasteners for fixing the KL 700 &KL 700 Plus clips to steel or timber purlins are as follows:

For Steel PurlinsAt least 3 threads should protrude past the support.

1mm to 4,5mm thickNo.10 - 16 x 16mm long self-drilling Wafer headPH2 screws #3 drill point.

5mm to 12,5mm thickNo.12 - 24 x 38mm long self-drilling Wafer headPH3 screws #5 drill point.

For Timber PurlinsThe screw should penetrate the purlin by the same depth recommened as if there were no insulation.

No.10 - 11 x 45mm long self-drilling Wafer headPH2 screws. Type 17 drill point.

Where insulation is installedBetween purlin and sheeting, the length of screws shouldbe increased, depending on the compressed thickness and density of the insulation. Please refer to the GRS Installation Manual for additional information on insulation fixing details.

*For light steel frame purlins less than 1mm thick, please contact GRS.

The Concealed Fixing Concept

Centre Ribs

Female Rib

41mm

700mm Cover

Male Rib

KL 700 Plus

KL 700 Plus

2nd. Klip-Lok 700 Sheet

1st. Klip-Lok 700 Sheet

Purlin

Klip-Lok 700 Profile

NoteFasteners must be selected to match the life expectancy of the roofing and cladding material. The coating class for fasteners, complying with SANS 1273, should be used in conjunction with all roofing and cladding material. For a full range of compatible fasteners, please refer to the GRS Installation Manual.

NoteWhere screws exceed 45mm long, they should be No.12 with a PH3 head.

KL 700

KL 700Plus

Page 4: Klip-Lok 700 Brochure 2017-professional - globalroofs.co.za · 2nd. Klip-Lok 700 Sheet 1st. Klip-Lok 700 Sheet Purlin Klip-Lok 700 Profile Note Fasteners must be selected to match

Sheet Lengths

Klip-Lok 700 is available, ex-factory, in sheetlengths limited only by transport restrictions;normal loads 12.5m and abnormal loads18.6m. Longer lengths can be milled on site,eliminating end laps, which are notrecommended.

End lapping negates the concealed fixconcept and no water tightness guaranteecan be given.

End lapping reduces the life expectancy ofthe roof, due to corrosion.

Bullnosing and Cranking Springing

Klip-Lok 700 can be sprung to a minimum radius of 36m (convex only) with internal span of purlins 1.5m maximum.

Additional Applications

NoteReverse cranking is not possible.

NoteConsideration for road transport has to be taken into account.

Refer to the GRS Installation Manual fordetailed dimensions and fixing instructions.

Site cranking for milled sheets is availableon application.

Rib Cap Detail

DIM ‘A” 90°95°

100°105°110°115°120°125°130°135°140°145°150°160°

Rib cap

450 min. radius

450 min. radius

75m

m m

in. r

unou

t75

mm

min

. run

out

75m

m m

in. r

unou

t

Please contact GRS for Insulation specific fixing details.

Sheet

150mm x 0.8mm thk.galvanized

steel bearing strip

Insulation by other

Sheet

U-SpacersLength of legs to suit insulation depth

Insulation by other

KL 700 / KL 700 Plus Clip

KL 700 / KL 700 Plus Clip

NoteAs a general rule, for transportable sheet lengths use a bearing strip and for longer sheet lengths use U-Spacers.

Page 5: Klip-Lok 700 Brochure 2017-professional - globalroofs.co.za · 2nd. Klip-Lok 700 Sheet 1st. Klip-Lok 700 Sheet Purlin Klip-Lok 700 Profile Note Fasteners must be selected to match

Profile: Klip-Lok 700™

Load Span Table

The recommended purlin support centres are based onthe following design criteria and obtained through testing:

Drainage Table

Maximum roof run (in metres) for roof slopes and rainfallintensities shown. These figures are based on unrestricted, free flow of water.

Ultimate Superimposed Distributed Load

Ultimate Uplift Load

ROOFS 1.50 kN/m²

Roof Slope250 300

648094

53667895

405058708391

400

Rainfall Intensity mm/h

Maximum Allowable Support Spacings

Type of SpanGALVANISED / CHROMADEK

0.5mmISQ550 (3T)

0.58mmISQ550 (3T)

0.47mmG550

0.53mmG550

0.5mmG550

0.55mmG550

Roofs Single Span End SpanInternal Span Cantilever (unstiffened)Cantilever (stiffened- max. sheet length of 13m)

Normal Mass kg/m² 5.5 6.6 5.1 5.7 5.2 5.75

1.400m1.700m2.000m0.180m0.400m

1.800m2.100m2.500m0.260m0.600m

1.300m1.600m1.900m0.150m0.350m

1.500m1.900m2.300m0.180m0.400m

1.400m1.700m2.000m0.150m0.350m

1.700m2.100m2.500m0.180m0.400m

1 in 50 (1º)1 in 30 (2º)1 in 20 (3º)1 in 12 (5º)1 in 7.5 (7.5º)1 in 6 (10º)

1.60 kN/m²

ZINCALUME / COLORBOND™ ZINCAL / COLORPLUS ® ®®®

500

324046566673

Page 6: Klip-Lok 700 Brochure 2017-professional - globalroofs.co.za · 2nd. Klip-Lok 700 Sheet 1st. Klip-Lok 700 Sheet Purlin Klip-Lok 700 Profile Note Fasteners must be selected to match

Sliding Bracket

Fixing points for flashing

FlashingStitching Screws

Popular Flashings

Available in 0.58mm / 0.8mm thick galvanised Z275 steel, 0.53mm thick Zincalume AZ150 or 0.55mm thick ZincAL AZ150. Or with a colour option Chromadek (Galvanised Z200), Clean COLORBOND™ (Zincalume AZ150) or COLORPLUS (ZincAL AZ150) finish to one / two sides.

® ®®

®®

®

Ridge or Hipcap50 min. Roofing Lipping Fixing Clip

S10 Clip

S10 ClipS10 Clip

S10 ClipCement tiles

180 mm Klip-Lok 700Sheets

S10 Clip

KL 700 ClipRoof

S10 Clip

S10 Clip

Counter FlashCounter Flash

Fixing Clip

Klip-Lok 700

Purlin

Side

wal

l Fl

ash

Hea

dwal

l Fl

ash

Girt

S10 Clip

Fixing Clip Stop End

Stop End

Stop End

Use sliding brackets when excessive expansion expected.

180 mm

Valley Gutter Ext. Corner Trim

Internal Corner Trim

Apron Flash Apex Flash

Sidewall Flash Detail Sidewall Flash Detail

Stop End

Please visit our website or contact GRS for standard flashing details.

When sheet lengths are over 30m flashings must be fixed to sheets using sliding brackets.*

Tools

Cladding180 min.

Notching ToolUsed to notch out sheet ribs profilein the flanges of flashings to fit over sheet ribs.

Turn-up ToolUsed to stop endsheets upward at thetop of the roof slopeto prevent water blownup and over sheet end.

Turn-down ToolUsed to lip sheetsdownward at the eaves to prevent water flowing backon the underside ofthe sheets.

e.&o.e@GRSRoofs

IsandoBloemfonteinCape TownDurbanEast London

Tel: +27 (0) 11 898 2900Tel: +27 (0) 51 432 3724Tel: +27 (0) 21 521 1900Tel: +27 (0) 31 538 0940Tel: +27 (0) 43 731 1895

MozambiqueNamibiaZambiaZimbabwe

Tel: +258 (002) 82 305 0506Tel: +264 (002) 61 263 890 Tel: +260 (002) 21 225 1315Tel: +263 (002) 477 4699

NelspruitMossel BayPolokwanePort ElizabethRustenburg

Tel: +27 (0) 13 492 0746Tel: +27 (0) 44 695 0014Tel: +27 (0) 51 293 0313Tel: +27 (0) 41 486 1270Tel: +27 (0) 14 596 6121

UpingtonExports BotswanaGhanaLesotho

Tel: +27 (0) 54 332 1656Tel: +27 (0) 11 898 2900Tel: +267 (002) 310 5761Tel: +27 (0) 11 898 2976Tel: +266 (002) 22 312 244