116
electric heating products commercial & industrial explosion-proof unit heater explosion-proof convector industrial unit heater washdown/corrosion resistant unit heater wall heater unit heater cabinet heater convector heater ceiling heater baseboard heater radiant panel wall heater electric heating and controls

Upload: vuliem

Post on 30-Aug-2018

227 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

e l e c t r i ch e a t i n g p r o d u c t s

c o m m e r c i a l & i n d u s t r i a l

explosion-proof unit heater

explosion-proof convector industrial unit heaterwashdown/corrosion resistant unit heater

wall heater unit heater cabinet heaterconvector heater

ceiling heater baseboard heater radiant panelwall heater

e l e c t r i c h e a t i n g a n d c o n t r o l s

Page 2: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

INTRODUCTIONHEATREX offers commercial and industrial electric heating and control systems that set the industry standard for excellence. The company’s heating solutions reflect more than 80 years of innova-tion, product quality and efficient service.

This catalog features HEATREX’s complete Space Heating line. Our products include Explosion-proof an explosion-proof convector; the Washdown/Corrosion Resistant Unit Heater; and several types of standard unit heaters.

HEATREX’s line of Comfort Heating Products cover a wide range of commercial and industrial applications. Whether the requirement is for architectural wall heaters, cabinet unit heaters, convector heaters or ceiling heaters, HEATREX has a product to match the application.

HEATREX’s quality is matched only by its cus-tomer service and support. With its quick-ship delivery program, HEATREX provides the prod-ucts you need.

Page 3: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

2

Table of ContentsAdvantages/Applications 3Use of Electric Heaters in Hazardous Locations 4-6

Comparison Chart 7-8Explosion-proof Unit Heaters

233 Series Explosion-proof Unit Heaters 9-15

236 Series Compact Explosion-proof Unit Heaters 16-18

254 Series Convector 19-26

Fan Forced HeatersComparison Chart 27

234 Series Washdown/Corrosion Resistant Unit Heaters 28-31

238 Series Industrial Unit Heater 32-34

240 Series Unit Heater 35-39

926 Series Unit Heater 40-43

925 Series Economical Unit Heater 44

928 Series Vertical Unit Heater 45-47

Wall, Ceiling and Floor HeatersComparison Chart 48-49

933 Series Architectural Wall Heater 50-52

932 Series Commercial Wall Heater 53-55

935 Series European Wall Heater 56

940 Series Hybrid Convection & Forced-Air Wall Heater 57

934 Series Wall Heater 58-59

930 Series Register Wall Heater 60-61

922 Series Cabinet Unit Heater 62-65

936/937 Series Commercial Ceiling Heater 66-69

931 Series Commercial Ceiling Heater 70-71

941 Series Forced-Air Ceiling Heater 72-73

938 Series Toe-Space Heater 74

939 Series Floor Insert Heater 75

Radiant PanelsAS Series 76-79918 Series Heater 80-81

Baseboard and Convector HeatersComparison Chart 83

903 Series Commercial Baseboard Heater 84-86

904/906 Series Architectural Sill-Height Convector 87-89

905/907 Series Industrial Sill-Height Convector 90-92

910 Series Aluminum Sill-Height Convec-tion Heater 93-95

908/909 Series Architectural Convector 96-99

914 Series Mini Draft Barrier Heater 100-102

916 Series High Watt Density Draft Barri-er Heater 103-105

911/912 Series Architectural Cabinet Convector 106-109

Thermostat Selection Chart 110

Thermstats 111-112

Color Section Chart 113

Limited Warranty 114-115

Page 4: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

3

Advantages/Applications

• Aircraft Hangars/Service Areas• Battery Storage Areas• Chemical Plants• Chemical Storage/Handling Areas• Coal Mines/Preparation Plants• Control Rooms• Dry Cleaning Plants• Dusty Areas Subject to Washdown• Food Processing Plants

(Washdown Areas)

• Foundries• Gasoline Fueling/Storage Areas• Grain Elevators• Hydrogen Atmospheres• Marine/Shipboard and Landbase Facilities• Natural Gas (Methane) Atmospheres• Oil Refineries• Offshore Drilling Rigs• Paint Spraying/Storage Areas

• Parking Garages• Petrochemical Plants• Pipeline Pumping Stations• Pulp and Paper Mills• Sewage/Wastewater

Treatment Plants• Solvent Recovery/

Storage Areas• Utility Plants

Hazardous and Corrosive Area Applications

• Basements• Classrooms• Conference Rooms• Entryways/Hallways• Factories• Lobbies

• Mechanical Rooms• Offices• Power Generating Stations• Pump Houses• Restrooms• Service Stations/Garages

• Shipping and Receiving Areas• Stairwells• Storage Areas• Vestibules• Warehouses• Workshops

Industrial and Commercial Applications

ExperienceThis catalog represents 80 years of experience in industrial electric heating – our specialty since HEATREX was founded in 1929. HEATREX has been manufacturing products for use in hazardous locations for over 55 years.

Complete Product LineHEATREX offers the industry’s most comprehensive line of space heating equipment. Explosion-proof unit heaters are available with ratings up to 30 kW and 600 volts. 234 Series unit heaters provide heat in non-hazardous environments where moisture and corrosion are present. Standard unit heaters include a heavy duty industrial model, several commercial models, vertical, cabinet and portable designs. A wide range of floor, wall and ceiling heaters, including baseboard heaters and radiant ceiling panels, are available to meet any application requirement. HEATREX also offers the widest selection of built-in controls in the industry.

Quick DeliveryA wide selection of assembly stock designs with options are available in two weeks. Most comfort heating products will ship in two weeks.

ColorsMany of HEATREX’s comfort heating products are avail-able in a choice of colors. Standard and special colors are shown in the back of this catalog. Custom colors, including bronze or clear anodizing and matches to customer supplied paint samples, are also available on select heaters.

SafetyHEATREX explosion-proof unit heaters include redun-dant overtemperature protection which exceeds agency requirements. The 233 Series unit heater has the indus-try’s lowest Ignition Temperature Code rating, 320°F (160°C), and is CSA Approved.

HEATREX corrosion resistant heaters are available with cULus Approvals. Explosion-proof and corrosion resistant heater designs are available for marine and shipboard use that are ABS Approved and meet U.S. Coast Guard require-ments.

HEATREX commercial and industrial unit heaters are UL and cUL Approved for non-hazardous, non-corrosive environments. Comfort heating products are CSAus or CSA Approved.

®�

American Bureau of Shipping

Page 5: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

4

IntroductionHazardous locations are those areas where a potential for explosion and fire exists due to the presence of flammable gases, vapors, pulverized dusts or ignitable fibers in the atmo-sphere. Hazardous locations are created from the normal pro-cessing of volatile chemicals, gases, coal, grains, etc., or from the accidental failure of storage systems for these materials.

Open flames are not permitted in these locations. The use of electric heating equipment is permitted with two major restric-tions: 1) The surface temperature of the equipment cannot exceed the ignition temperature of the hazardous atmosphere and 2) all arc and spark producing devices must be isolated from the atmosphere in an appropriate enclosure.

Both people and equipment in hazardous locations can be heated safely and economically with electric heat. Electric heating is typically much less expensive to install and maintain than caparable remote oil or gas fired heating systems.

National Electrical Code ClassificationArticles 500 through 516 of the National Electrical Code deal with the definition of hazardous areas and the use or design of electrical equipment used in these locations. Electric heating equipment for hazardous areas is specified based on the NEC class, division, group and ignition temperature or the alter-nate class and zone classification.

ClassHazardous locations are divided into the three general classes of vapors/gases, dusts and fibers.

Class I – Locations where the potential for explosion and fire exists due to the presence of flammable gases or vapors in the air. Typical Class I locations include oil or natural gas drilling rigs, petroleum refining or pumping facilities, petro-chemical plants, wastewater/sewage treatment plants, solvent extraction plants, paint spraying booths, locations where open tanks or vats of combustible liquids are present and storage areas for flammable materials.

Class II – Locations where the potential for explosion exists because of finely pulverized flammable dusts suspended in the atmosphere. Typical locations would include coal fired power plants, coal preparation/coal handling facilities, coal mines, grain elevators, flour and feed mills, packaging and han-dling of pulverized sugar and processing and storage of mag-nesium and aluminum powder.

Class III – This third classification is primarily a fire hazard where fibers or flyings suspended in the air create a hazard. This would include small pieces of thread-like fiber, sawdust, lint, etc. Typical applications would include textile mills, wood-working plants, cotton gins, cotton seed mills and flax produc-ing plants.

DivisionClass I, Class II and Class III areas are further defined in terms of when the hazard occurs. Division 1 and Division 2 occur-rences are summarized below.

Division 1 – If the hazard is expected to be present under normal conditions, such as a production or processing facil-ity, the occurrence is designated Division 1. The hazardous atmosphere may be present continuously, intermittently, peri-odically, or during normal repair or maintenance operations. Division 1 occurrences also include locations where a break-down in the operation of processing equipment results in the release of hazardous vapors.

Division 2 – If the hazardous material is normally expected to be contained within a closed area, system or container, and would enter the ambient atmosphere only under an abnormal failure, then it is referred to as a Division 2 occurrence.

Use of Electric HeatersIn Hazardous Locations

Page 6: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

5

Use of Electric HeatersIn Hazardous Locations

GroupThe nature and explosive characteristics of the hazardous materi-al are defined by the NEC group to which it is assigned.

Class I – Hazardous vapors/gas locations include chemicals and other materials that have been divided into four groups based on their ignition temperature and explosive characteristics. (Groups A, B, C and D)

Class II – Hazardous dust locations are divided into three groups based on their ignition temperature and electrical conductivity of the suspended particles.

Group E – Atmospheres containing metal dust, such as alumi-num or magnesium.

Group F – Atmospheres containing coal, charcoal or coke dust.

Group G – Atmospheres with grain, flour, starch, combustible plastics or chemical dust.

Class III – Locations have no group definitions.

Class and Zone ClassificationsClass I, Zone 0 – Locations in which ignitable concentrations of flam-mable gases or vapors are present continuously or for long periods.

Class I, Zone 1 – Locations in which ignitable concentrations of flammable gases or vapors are likely to exist, may exist frequently or exist as a result of equipment breakdown or faulty operation. Applies to locations adjacent to a Class I, Zone 0 location.

Class I, Zone 2 – Locations in which ignitable concentrations of flam-mable gases or vapors are not likely to occur under normal opera-tion, exist only for a short period or exist only as a result of acciden-tal failure, such as rupture or breakdown of the container or system, abnormal operation of equipment, failure or abnormal operation of the ventilation equipment. Applies to locations adjacent to a Class I, Zone 1 location.

Material GroupsGroup IIC – Atmospheres containing acetylene or hydrogen. Equivalent to a combination of Class I, Group A and Class I, Group B as described in NEC Article 500.

Group IIB – Atmospheres containing acetaldehyde. Equivalent to Class I, Group C as described in NEC Article 500.

Group IIA – Atmospheres containing acetone, ammonia, ethyl alco-hol, gasoline, methane or propane. Equivalent to Class I, Group D as described in NEC Article 500. Ignition Temperature

All electrical equipment is designed not to exceed the ignition temperature of the hazardous atmosphere. The maximum surface temperature for electric heaters is defined by the NEC.

Product use depends on temperature class. The temperature code indicates the maximum temperature of the exposed surface of the product. For Zone classified dusts the explosion-proof temperature is the maximum surface temperature is shown as e.g. T800C

Class, Division Classification Zone ClassificationTemperature Class

(T Code)Maximum Surface

Temperature 0F (0C)Temperature Class

(T Code)Maximum Surface

Temperature 0CT1 ≤ 842 (≤ 450) T1 ≤ 450T2 ≤ 572 (≤ 300) T2 ≤ 300

T2A ≤ 536 (≤ 280) T3 ≤ 200T2B ≤ 500 (≤ 260) T4 ≤ 135T2C ≤ 446 (≤ 230) T5 ≤ 100T2D ≤ 419 (≤ 215) T6 ≤ 85T3 ≤ 392 (≤ 200)

T3A ≤ 356 (≤ 180)T3B ≤ 329 (≤165)T3C ≤ 320 (≤ 160)T4 ≤ 275 (≤135)

T4A ≤ 248 (≤ 120)T5 ≤ 212 (≤100)T6 ≤ 185 (≤ 85)

Page 7: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

6

Use of Electric HeatersIn Hazardous Locations

Electric heating equipment can be economically designed and safely used in hazardous areas if the following special require-ments are observed.1. The surface temperature of the electric heating equipment

cannot exceed the ignition temperature of the hazardous atmosphere. To insure that the proper heater has been select-ed, it is essential that the correct NEC Ignition Temperature Code be specified.

If the temperature code selected is too high, the electric heating system may operate above the ignition point of the application, creating a potentially hazardous condition.

2. All arc and spark-producing control devices must be isolated from the hazardous atmosphere. If it is not economically fea-sible to locate the control devices in the non-hazardous area, they must be housed in an enclosure that will withstand the pressure of a potential explosion from within the enclosure.

3. All electrical supply connections must be made according to the latest NEC and local code requirements for hazardous loca-tions. This includes the requirement that conduit entering the enclosures must be provided with seals at the enclosure.

Special Requirements for Electric Heating Equipment used in Hazardous Areas

CLASS I - HAZARDOUS GAS ATMOSPHERES CLASS I - HAZARDOUS GAS ATMOSPHERESIgnition Temp. NEC Ignition Temp. NEC

Group Material °F °C Code Group Material °F °C CodeA Acetylene 581 305 T2 D Methyl Isobutyl Ketone 840 448 T2

B Acrolein (Inhibited) 428 220 T2D 2-Methyl-1-Propanol780 415 T2

Butadiene 788 420 T2 (Isobutyl Alcohol)Ethylene Oxide 804 429 T2 Petroleum Naptha 550 288 T2AHydrogen 932 500 T1 Pyridine 900 482 T1Propylene Oxide 840 449 T2 Octanes 403 206 T3Propyl Nitrate 347 175 T3B Pentanes 500 260 T2B

C Acetaldehyde 347 175 T3B 1-Pentanol (Amyl Alchohol) 650 343 T2

Allyl Alcohol 713 378 T2 Propane 842 450 T1Carbon Monoxide 1128 609 T1 1-Propanol (Propyl Alchohol) 775 412 T2Cyclopropane 928 498 T1 2-Propanol (Isopropyl Alcohol) 750 399 T2Ethylene 842 450 T1 Propylene 851 455 T1Hydrogen Cyanide 1000 538 T1 Styrene 914 490 T1Hydrogen Sulfide 500 260 T2B Toluene 896 480 T12-Nitropropane 802 428 T2 Vinyl Acetate 756 402 T2Tetrahydrofuran 610 321 T2 Vinyl Chloride 882 472 T1

D Acetic Acid (Glacia) 867 463 T1Xylenes

867- 463- T1Acetone 869 465 T1 984 528Ammonia, Anhydrous 1204 651 T1 CLASS II - HAZARDOUS DUST ATMOSPHERESBenzene 928 498 T1 Ignition Temp. NECButane 550 287 T2A Group Material °F °C Code1-Butanol (Butyl Alcohol) 650 343 T2 E Aluminum, A422 Flake 608 320 T22-Butanol

761 405 T2Calcium Silicide 1004 540 T1

(Secondary Butyl Alcohol) Manganese 464 240 T2CEthane 882 472 T1 Magnesium, Grade B, Milled 806 430 T2Ethanol (Ethyl Alcohol) 685 363 T2 F Charcoal 356 180 T3AEthyl Acetate 800 427 T2 Coal, Kentucky Bituminous 356 180 T3AEthylene Dichloride 775 413 T2 Coal, Pittsburgh Experimental 338 170 T3BGasoline (56-60 Octane) 536 280 T2A Pitch, Petroleum 1166 630 T1

Gasoline (100 Octane) 853 456 T1 G Alkyl Ketone Dimer320 160 T3C

Heptanes 399 204 T3 Sizing CompoundHexanes 437 235 T2D Corn 482 250 T2CIsoprene 428 220 T2D Corn Starch, Modified 392 200 T3Isopropyl Ether 830 443 T2 Polyurethane Foam,

734 390 T2Methane (Natural Gas)

900- 482- T1 Fire Retardant1170 632 Shellac 752 400 T2

Methanol (Methyl Alcohol) 867 454 T1 Soy Flour 374 190 T3A3-Methyl-1-Butanol

662 350 T2Sugar, Powdered 698 370 T2

(Isoamyl Alcohol) Sulfur 428 220 T2DMethyl Ethyl Ketone 759 404 T2 Wheat 428 220 T2D

Wood Flour 500 260 T2B

The materials given are found in NFPA 497, 1991 and NFPA 325, 2001.

Page 8: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

7

Comparison Chart

Heatrex offers a selection of explosion-proof heater constructions to meet your specific application.

233 SeriesOur most popular and versatile construction has a broad range of stock designs, special options and the industry’s lowest Ignition Temperature Code rating, 320°F (160°C).

Features 233 Series

Hazardous LocationNEC Classifications

Class I, Divisions 1 and 2, Groups C and D Class II, Divisions 1 and 2, Groups E, F, and G

Class 1, Zones 1 and 2, Groups IIB

Ignition Temperature Code T3C320°F (160°C)

KW Range Up to 30 KW

Standard Built-in Overtemperature Protection Dual overtemperature protection with automatic and manual reset thermal cutouts

Other Standard Built-in Controls Controlling contactor,control circuit transformer

Standard Control Voltage 24V

Single Point Line Voltage Connectionfor Incoming Power Yes

Optional Built-in Controls

Thermostat Yes

Disconnect Switch Yes

Selector Switch Yes

Manual Reset Cutout Standard

“Heater On” Pilot Light Yes

“Warning” Pilot Light Yes

Control Circuit Transformer Standard

Standard Construction

Heater Assembly Liquid-to-air heat exchanger, steel tube with aluminum fins, propylene glycol, immersion heater

Cabinet/Housing Powder coated galvanized steel

NEMA 7, 9 Control Enclosure Cast aluminum

Mounting Brackets Wall, ceiling or pole mounting kits (optional)

Optional Constructions

Dirty Duty Corrosion Resistant Choice of 316SS Construction or Heresite® coating

Wet Location Suitable for IP55 wet locations

50 Hertz Motor Yes

Agency Approvals

cCSAus

Page 9: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

8

236 SeriesThe industry’s smallest and most economical design for Class I, Group D applications up to 12 KW.

Comparison Chart254 SeriesSmall, compact design with a wide range of optional built-in controls.

236 Series 254 Series

Class I, Divisions 1 and 2, Group DClass 1, Zones 1 and 2, Group IIA

Class I, Divisions 1 and 2, Groups B, C and D Class II, Divisions 1 and 2, Groups E, F, and G

Class 1, Zones 1 and 2, Groups IIC

T3392°F (200°C) (Varies with KW)

T3C320°F (160°C) (Varies with classification)

Up to 12 KW Up to 9.5 KW

Primary and secondary automaticreset cutouts with fan relay Primary automatic reset cutout

Controlling contactor None

120V Maximum 277V

Separate 120V motor line required Yes

Yes Yes

No No

No No

Yes No

No No

No No

No Yes

Stainless steel finnedtubular elements

Heater core enclosed in copper tubewith large aluminum fins

Stainless steel Powder coated galvanized steel

Cast aluminum Cast aluminum

Swivel mounting bracket (standard) Wall mounting bracket (standard)

Yes Wet locations (Type 3) iridite coated elements

No Wet locations (Type 3) iridite coated elements

No N/A

cCSAus & ABS cCSAus & ABS

Page 10: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

9

233 Series Unit Heater

Heatrex’s 233 Series explosion-proof unit heater is designed with both safety and versatility in mind.

• Industry’s Lowest Ignition Temperature Code Rating: T3C, 320°F (160°C)

• Dual Overtemperature Protection: With both automatic and manual reset overtemperature cutouts for additional safety.

• Optional wet location construction, which includes IP55 motor, type 4 outdoor rated enclosure and meets rain-tight requirements of UL 1004-1.

• Nontoxic Propylene Glycol Heat Transfer Fluid

• Low 70 PSIG Relief Valve Setting: This assures that in an emergency, the initial escaping vapor temperature remains below the 320°F (160°C) ignition temperature.

• Corrosion Resistant Options: Heatrex offers three con-structions suitable for most applications.

Standard construction for use in dry non-corrosive areas includes: welded steel heat exchanger; powder-coated cabinet.

A 316 stainless steel construction suitable for Waste Water Treatment Plants includes: 316 stainless steel heat exchanger, headers and tubes with aluminum fins; stain-less steel cabinet; corrosion resistant hardware.

Third construction is suitable for use in Chemical Plants where chlorides are present and includes: Heresite® coat-ed heat exchanger, cabinet, fan blade; corrosion resistant hardware.

Class I, Divisions 1 and 2, Groups C and DClass II, Divisions 1 and 2, Groups E, F and GClass I, Zones 1 and 2, Group IIBTemperature Code T3C, 320°F (160°C)

Applications• Aircraft Hangars/Service Areas

• Chemical Storage/Handling Areas

• Coal Preparation Plants

• Compressor Stations

• Grain Elevators

• Oil Refineries and Rigs

• Paint Storage Areas

• Petrochemical Plants

• Sewage Pump Stations/ Treatment Plants

• Spray Booths

Standard Construction FeaturesHeat Exchanger – Efficient liquid-to-air design utilizes an all welded steel headers and finned tube construction with spiral wound aluminum fins. Industrial grade Heatrex heating ele-ments are immersed in a nontoxic, inhibited, propylene glycol heat transfer fluid that provides freeze protection down to -49°F (-45°C). The heat exchanger is hydrostatically tested at 350 psig. A pressure relief valve provides excess pressure protection and is set at 70 psig.

Fan Motor Assembly – Consists of an explosion-proof motor fitted with an aluminum fan blade. The motor has double- shielded, permanently lubricated ball bearings and automatic reset line breaking thermal overload protection. Motors fur-nished on standard units operate at line voltage and are pre-wired to the control enclosure so separate field wiring to the motor is not required. The standard motor is rated for Class I,

Groups C and D, Class II, Groups F and G. The minimum oper-ating temperature is -14°F (-25°C) and the minimum storage temperature is -49°F (-45°C). Optional motor ratings are described on page 9.

Cabinet/Louvers – Industrial grade, corrosion resistant construction fabricated from beige powder coated 14-gauge galvanized steel. The adjustable louvers have minimum opening safety stops.

Controls – Factory mounted on the unit heater. Standard built-in controls include automatic and manual reset overtem-perature cutouts, controlling magnetic contactor, and 24-volt control circuit transformer housed in a NEMA 7, 9 cast alumi-num enclosure.

Page 11: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

10

Code Option Description AvailabilityCode (2)

C1

316 Stainless SteelCorrosion-ResistantConstruction (WasteWater Treatment Plants)

316 Stainless steel heat exchanger with aluminum fins, 316 stainless steel cabinet; aluminum fan blade; cast aluminum NEMA 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor, which has passed the ASTM B117 salt-spray test.

C

C2Dirty Duty Corrosion-Resistant Construction(Chemical Plants)

Heresite® coated heat exchanger, cabinet and fan blade; cast aluminum NEMA 7, 9 control enclosure; corrosion-resistant hardware; corrosion-resistant protective coated motor which has passed the ASTM B117 salt-spray test.

C

D Disconnect Switch

Factory installed on the unit heater above the control enclosure. This is an inexpensive and positive way to meet NEC/CEC requirements for a disconnecting means within sight of the heater.

AS

E* Group E (Metal Dust)Construction

Class II, Group E (Metal Dust) Construction Temperature Code T3C, 320°F (160°C) C

K “Warning” Pilot Light Indicates when the thermal cutouts have tripped and the unit heater needs servicing. AS

L “Heater On” Pilot Light Indicates when the electric heating elements are energized. AS

MManual ResetThermal Cutout withBackup Contactor

A pilot duty manual reset thermal cutout with a backup contactor is provided for independent secondary overtem-perature protection. This option cannot be provided if option Code S or V are also specified.

AS

S Auto/FanSelector Switch

A two-position switch wired to the control circuit for auto (au-tomatic heat) and fan only control. This selector switch cannot be provided if option Code M or V are also specified.

AS

S1 Built-In Controls for Remote Auto/Fan Selector Switch

Unit is prewired for field addition of remote auto/fan selector switch. This option cannot be provided if Code M or V are also specified.

AS

T Adjustable ThermostatFactory installed and prewired to the control enclosure. Ther-mostat is adjustable from 50° to 90°F(10° to 32°C) range.

AS

T1 Adjustable Thermostat for Wet Locations

Factory installed and prewired to the control enclosure. Ther-mostat is adjustable from 40˚ to 80˚F (5˚ to 25˚C) range. Can be specified for all constructions.

AS

V 120 Volt Control CircuitCan be provided when required for special external thermo-stat circuit. This option cannot be provided if option Code S or M are also specified. Nor can both K and L be specified.

AS

W Wet Location Construction Features – IP55

Unit provided with components suitable for IP55 wet loca-tions. Requires dirty duty corrosion-resistant or 316 stainless steel corrosion-resistance construction option.

AS

233 Series Unit Heater

Factory Built-in Options

(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.* Code E cannot be selected when selecting Code W.

Page 12: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

11

Ceiling Mounting KitWall Mounting Kit

Pole Mounting Kit

233 Series Unit Heater

233 Series Heater Mounting KitsThese are available for ceiling, wall and pole mounting config-urations as described below. Specify type required and catalog number at time of order entry.

Unit Heater Mounting Kits (One kit required per heater) Standard Mounting Kits for use in most applications

Accessory Items

Optional Mounting Kits for Option C1 or C2 heaters

Size MH In. (mm) MW In. (mm)1 11.063 (281) 9 (228.6)2 15.063 (382.6) 7 (177.8)3 19.063 (484.2) 5 (127)

CatalogNumber Description Availability

Code (2)1022451 Ceiling Mounting Kit, for Frame Size 1, 2, 3

AS1022454 Wall Mounting Kit, for Frame Size 1, 2, 31022457 Pole Mounting Kit, for Frame Size 1, 2, 3

CatalogNumber Description Availability

Code (2)1022451-S Corrosion Resistant Ceiling Mounting Kit, for Frame Size 1, 2, 3

AS1022454-S Corrosion Resistant Wall Mounting Kit, for Frame Size 1, 2, 31022457-S Corrosion Resistant Pole Mounting Kit, for Frame Size 1, 2, 3

(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.

ULTRA-SAFE EXPExplosionproof Unit Heater

ULTRA-SAFE EXPExplosionproof Unit Heater

ULTRA-SAFE EXPExplosionproof Unit Heater

6-⅛”(159.76mm)

5”(127mm)

5”(127mm)

2-½”(63.5mm)

MH

MH

MH

Page 13: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

12

Accessory Remote Thermostat

Remote Fan Switch

Catalog Number Switch Type Description Type Ratings

Temp.RangeoF (oC)

Availability Code

1007002 Bimetal Class 1, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G SPDT 125-277V,

22A50-90

(10-32)

AS

1030790 Bimetal

Class I, Div. 1, Groups C & DClass II, Div. 1, Groups E, F, & G

Class IIIIP66, Type 4

SPDT 480V,22A

40-80 (5-25)

Catalog Number Switch Type Description Hubs Ratings Availability

Code

1001744 2-PositionClass I, Div. 1, Groups C & D

Class II, Div. 1, Groups E, F, & GClass III

(2) 3/4” NPT Hubs

120/277V30A

AS

1031042 2-Position

Class I, Div. 1, Groups C & DClass II, Div. 1, Groups E, F, & G

Class IIINEMA 4X

(2) 3/4” NPT Hubs

110V6A

233 Series Unit Heater

Page 14: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

13

Dimensions, Airflows and Weights

60 Hertz Heaters

50 Hertz Heaters

233 Series Unit Heater

Side View Front View

Frame Size Size 1 Size 2 Size 3

OverallHeaterDimensions

‘X’ In. (mm) 21.75 (552.45) 21.75 (552.45) 22.75 (577.85)

‘Y’ In. (mm) 19.375 (492.125) 23.375 (593.725) 27.375 (695.325)

‘Z’ In. (mm) 16.063 (408) 20.188 (512.775) 24.188 (614.375)

WeightNet Lbs. (kgs) 110 (49.89) 150 (68.03) 190 (86.18)

Shipping Lbs (kgs) 130 (58.96) 169 (76.65) 216 (97.97)

KW Range 3 - 5 7.5 - 10 15 20 25 30

AirflowCharacteristics

Air Volume CFM(cubic meter/hr.)

650(1104)

850(1444)

1800(3058)

3110(5283)

3850(6541)

Air Throw Feet (m) 15 (4.5) 25 (7.6) 45 (13.7) 65 (19.8) 75 (22.8)

Motor/Fan

RPM 1725

HP 1/4 1/2

Fan Blade Dia. In. (mm) 12 (304.8) 16 (406.4) 20 (508)

KW Range 2.5 - 4.2 6.3 - 8.4 12.5 16.7 21 - 25

AirflowCharacteristics

Air Volume CFM(cubic meter/hr.)

550(934)

700(1189)

1500(2549)

2600(4417)

Air Throw Feet (m) 13 (4) 22 (7) 39 (12) 57 (17)

Motor/Fan

RPM 1438

HP 1/4 1/2

Fan Blade Dia. In. (mm) 12 (304.8) 16 (406.4) 20 (508)

ULTRA-SAFE EXPExplosionproof Unit Heater

CAUTION

ATTENTION

CAUTIONATTENTION

X

Y

6-¾” Z

Page 15: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

14

233 SeriesUnit Heater Listing 60 Hz

Class I, Divisions 1 and 2, Groups C and DClass II, Divisions 1 and 2, Groups F and GClass I, Zones 1 and 2, Group IIBTemperature Code T3C, 320°F (160°C)

233 Series Unit Heater

(1) Total Amps = Heating element amps and motor amps.(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.

KW Volts Phase TotalAmps (1)

FrameSize

Approximate AirTemperature Rise

°F (°C)

CatalogNumber

Availability(2)

3

208 1 17 1 15 (8) HX-233-FA-0036C

AS

240 1 15 1 15 (8) HX-233-FA-0036J

208 3 10 1 15 (8) HX-233-FA-0036D

240 3 9 1 15 (8) HX-233-FA-0036K

480 3 5 1 15 (8) HX-233-FA-0036U

600 3 4 1 15 (8) HX-233-FA-0036Z

5

208 1 26 1 25 (13) HX-233-FA-0056C

240 1 23 1 25 (13) HX-233-FA-0056J

208 3 16 1 25 (13) HX-233-FA-0056D

240 3 14 1 25 (13) HX-233-FA-0056K

480 3 7 1 25 (13) HX-233-FA-0056U

600 3 6 1 25 (13) HX-233-FA-0056Z

7.5

208 1 38 1 28 (16) HX-233-FA-0086C

240 1 34 1 28 (16) HX-233-FA-0086J

208 3 23 1 28 (16) HX-233-FA-0086D

240 3 20 1 28 (16) HX-233-FA-0086K

480 3 10 1 28 (16) HX-233-FA-0086U

600 3 9 1 28 (16) HX-233-FA-0086Z

10

240 1 44 1 38 (21) HX-233-FA-0106J

208 3 30 1 38 (21) HX-233-FA-0106D

240 3 26 1 38 (21) HX-233-FA-0106K

480 3 13 1 38 (21) HX-233-FA-0106U

600 3 11 1 38 (21) HX-233-FA-0106Z

15

208 3 44 2 27 (15) HX-233-FB-0156D

240 3 38 2 27 (15) HX-233-FB-0156K

480 3 19 2 27 (15) HX-233-FB-0156U

600 3 16 2 27 (15) HX-233-FB-0156Z

20480 3 25 2 35 (19) HX-233-FB-0206U

600 3 21 2 35 (19) HX-233-FB-0206Z

25480 3 31 3 26 (14) HX-233-FC-0256U

600 3 25 3 26 (14) HX-233-FC-0256Z

30480 3 37 3 25 (13) HX-233-FC-0306U

600 3 30 3 25 (13) HX-233-FC-0306Z

Page 16: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

15

233 SeriesUnit Heater Listing 50 Hz

233 Series Unit Heater

Class I, Divisions 1 and 2, Groups C and DClass II, Divisions 1 and 2, Groups F and GClass I, Zones 1 and 2, Group IIBTemperature Code T3C, 320°F (160°C)

(1) Total Amps = Heating element amps and motor amps.(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.

KW Volts Phase TotalAmps (1)

FrameSize

Approximate AirTemperature Rise

°F (°C)

CatalogNumber

Availability(2)

2.5

220 1 14 1 14 (8) HX-233-FA-0036E

C

220 3 9 1 14 (8) HX-233-FA-0036F

380 3 6 1 14 (8) HX-233-FA-0036G

400 3 6 1 14 (8) HX-233-FA-0036H

415 3 5 1 14 (8) HX-233-FA-0036I

4.2

220 1 21 1 24 (13) HX-233-FA-0056E

220 3 13 1 24 (13) HX-233-FA-0056F

380 3 9 1 24 (13) HX-233-FA-0056G

400 3 8 1 24 (13) HX-233-FA-0056H

415 3 7 1 24 (13) HX-233-FA-0056I

6.3

220 1 31 1 28 (16) HX-233-FA-0076E

220 3 19 1 28 (16) HX-233-FA-0076F

380 3 12 1 28 (16) HX-233-FA-0076G

400 3 11 1 28 (16) HX-233-FA-0076H

415 3 10 1 28 (16) HX-233-FA-0076I

8.4

220 1 40 1 38 (21) HX-233-FA-0096E

220 3 24 1 38 (21) HX-233-FA-0096F

380 3 15 1 38 (21) HX-233-FA-0096G

400 3 13 1 38 (21) HX-233-FA-0096H

415 3 13 1 38 (21) HX-233-FA-0096I

12.5

220 3 35 2 26 (14) HX-233-FB-0136F

380 3 21 2 26 (14) HX-233-FB-0136G

400 3 19 2 26 (14) HX-233-FB-0136H

415 3 18 2 26 (14) HX-233-FB-0136I

16.7

220 3 46 2 35 (19) HX-233-FB-0176F

380 3 28 2 35 (19) HX-233-FB-0176G

400 3 25 2 35 (19) HX-233-FB-0176H

415 3 24 2 35 (19) HX-233-FB-0176I

21

380 3 33 3 26 (14) HX-233-FC-0216G

400 3 32 3 26 (14) HX-233-FC-0216H

415 3 31 3 26 (14) HX-233-FC-0216I

25

380 3 39 3 30 (17) HX-233-FC-0256G

400 3 37 3 30 (17) HX-233-FC-0256H

415 3 36 3 30 (17) HX-233-FC-0256I

Page 17: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

16

236 Series Unit Heater

Heatrex’s 236 Series explosion-proof unit heater is designed with both size and economy in mind.

• Compact Size: This small design is only 13 inches wide, which makes it ideal for applications where limited space is avail-able.

• Low Cost: The design offers the most economical solution for heating small Class I, Group D hazardous areas. It is a cost effective alternative to the use of explosion-proof con-vection heaters.

• Redundant Overtemperature Protection: Primary and secondary automatic reset thermal cutouts for additional safety.

• Stainless Steel Construction: Provides superior corrosion resistant protection. Optional Dirty Duty construction adds polyester powder coating to all aluminum parts for use in corrosive applications.

American Bureau of Shipping

Applications• Chemical Storage/ Handling

Areas

• Compressor Stations

• Marine and Offshore

• Oil Platforms and Refineries

• Sewage/Wastewater Treatment Plants

• Spray Booths

Standard Construction FeaturesHeating Elements – Industrial grade, Type 304 stainless steel finned tubular heating elements are manufactured by Heatrex.

Terminal Enclosure – A NEMA 7, 9 cast aluminum enclosure with a threaded bottom cover permits easy access to the built-in controls from underneath the heater.

Housing – Round, 16-gauge stainless steel shroud.

Grilles – An adjustable stainless steel louvered outlet grille directs airflow 45° up or down and a heavy gauge stainless steel rear grille protects against accidental contact with the fan blade.

Stainless Steel Swivel Mounting Bracket – Supplied as stan-dard with all 236 Series explosion-proof unit heaters. This multi-purpose bracket can be used for either wall or ceiling mounting.

Built-In Controls – Include primary and secondary automatic reset overtemperature cutouts, controlling contactor, and a time delay relay which keeps the fan running to cool the heat-ing elements after they have been de-energized.

Fan Motor Assembly – Consists of a 120-volt, 1-phase 60 hertz motor fitted with an aluminum fan blade. The totally enclosed motor is UL Listed for Class I, Group D applications and includes permanently lubricated ball bearings and built-in thermal overload protection. The motor is factory wired into the enclosure to reduce field wiring, but requires a separate 120-volt power supply.

Class I, Divisions 1 and 2, Group DClass I, Zones 1 and 2, Group IIA

Page 18: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

17

236 Series Unit Heater

Dimensions, Airflows and Weights

Custom Options

Standard Wall and Ceiling Installation with Swivel Mounting Bracket

Code Option Description AvailabilityCode (2)

C Dirty Duty CorrosionResistant Construction

Includes polyester powder coated fan blade, wiring conduit and fittings, NEMA 4X, 7, 9 enclosure. C

CM Marine DutyConstruction

Dirty Duty Construction with manual reset thermal cutout. Meets U.S. Coast Guard requirements per 46CFR-111.87 and is ABS Approved C

M Manual Reset Cutout Can be specified to replace secondary automatic cutout. C

T Adjustable Thermostat Factory installed and prewired to the control enclosure. Thermostat is adjustable from 50° to 90°F (10° to 32°C) range. C

(2) AS = Assembly Stock, C = Custom Assembly Stock heaters ordered with custom options are subject to longer delivery.

KW 3 5 7 10 12Ignition Temperature Code T3 T2C T2 T1 T1

Approximate Air Temperature Rise °F (°C) 9 (5) 15 (8) 22 (12) 31 (17) 37 (21)

AirflowCharacteristics

Air Volume CFM(cubic meters/hr)

1050(1784)

1050(1784)

1050(1784)

1050(1784)

1050(1784)

Air Throw Feet (m) 25 (8) 25 (8) 25 (8) 25 (8) 25 (8)Outlet Velocity FPM

(meters/min)1140(348)

1140(348)

1140(348)

1140(348)

1140(348)

Motor/FanRPM 1725 1725 1725 1725 1725HP 1/6 1/6 1/6 1/6 1/6

Fan Blade Dia. Inch ( cm) 12 (31)

WeightNet Lbs (kgs) 96 (44)

Shipping Lbs (kgs) 110 (50)

Swivel Bracket(Ceiling Mounted)

9 ¼”(48.9 cm)

8” Min(20.3 cm)

5 ¾”(14.6 cm)

8” Min(20.3 cm)

18” Ref.(45.7 cm)

22”(55.9 cm)

HeaterWiring

28 ¼”(71.8 cm)

Max

4⅜”(11.1 cm)

Min

15 16”

(3.3 cm)Min

120V Motor:Control Wiring When Optional Built-On Thermostat is Used

120V Motor:Control Wiring

When Optional Built-On Ther-

mostat is Used

Optional Built-On Thermostat

AIRFLOW

20”(50.8 cm)

13”(33 cm)

WA

LL

CEILINGCEILING

Page 19: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

18

236 Series Unit Heater

Heater Listing

(1) The amps shown are for the heating elements only. The 120V, 1 Ph 60 Hz motor draws 3.8 amps and requires a separate 120V power supply.(2) Availability Code: C = Custom

Class I, Divisions 1 and 2, Group DClass I, Zones 1 and 2, Group IIA

American Bureau of Shipping

IgnitionTemperature

Code°F (°C)

KW Volts PhaseHeaterAmps

(1)

CatalogNumber

AvailabilityCode (2)

T3392 (200) 3

208 1 14.5 HX-236-F01T-0037C-7300 C240 1 12.5 HX-236-F01T-0037J-7301 C480 1 6.3 HX-236-F01T-0037T-7302 C208 3 8.4 HX-236-F01T-0037D-7303 C240 3 7.3 HX-236-F01T-0037K-7304 C480 3 3.7 HX-236-F01T-0037U-7305 C600 3 2.9 HX-236-F01T-0037Z-7306 C

T2C446 (230) 5

208 1 24.1 HX-236-F01T-0055C-7307 C240 1 20.9 HX-236-F01T-0055J-7308 C480 1 10.5 HX-236-F01T-0055T-7309 C208 3 13.9 HX-236-F01T-0055D-7310 C240 3 12.1 HX-236-F01T-0055K-7311 C480 3 8.1 HX-236-F01T-0055U-7312 C600 3 4.9 HX-236-F01T-0055Z-7313 C

T2572 (300) 7

208 1 33.7 HX-236-F01T-0072C-7314 C240 1 29.2 HX-236-F01T-0072J-7315 C480 1 14.6 HX-236-F01T-0072T-7316 C208 3 19.5 HX-236-F01T-0072D-7317 C240 3 16.9 HX-236-F01T-0072K-7318 C480 3 8.5 HX-236-F01T-0072U-7319 C600 3 6.8 HX-236-F01T-0072Z-7320 C

T1842 (450) 10

240 1 41.7 HX-236-F01T-0101J-7321 C480 1 20.9 HX-236-F01T-0101T-7322 C208 3 27.8 HX-236-F01T-0101D-7323 C240 3 24.1 HX-236-F01T-0101K-7324 C480 3 12.1 HX-236-F01T-0101U-7325 C600 3 9.7 HX-236-F01T-0101Z-7326 C

T1842 (450) 12

480 1 25.0 HX-236-F01T-0121T-7327 C240 3 29.0 HX-236-F01T-0121K-7328 C480 3 14.5 HX-236-F01T-0121U-7329 C600 3 11.6 HX-236-F01T-0121Z-7330 C

Accessory Remote ThermostatCatalog Number Switch Type Description Type Ratings

Temp.RangeoF (oC)

Availability Code

1007002 Bimetal Class 1, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G SPDT 125-277V,

22A50-90

(10-32)

AS1024754 Bulb and Capillary with Internal Set Point Adjustment

Class 1, Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G SPDT

120-240V,25A

277V, 22A

40-120(5-49)

1025396 Bulb and Capillary with Internal Set Point Adjustment

Corrosion-Resistant Class 1, Div. 1,Groups B, C, & D

Class II, Div. 1, Groups E, F & GSPST

120-240V,25A

277V, 22A

40-120 (5-49)

Page 20: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

19

254 Series Convector

Standard Construction FeaturesElement – Grade A Nickel-Chromium heating coils are insulated with ceramics and magnesium oxide from the copper heater tube and fitted with large aluminum fins locked in place.

Cabinet – Heavy gauge galvanized steel cabinet is painted with a beige powder coat for durability. Cabinet should be mounted at least 6 inches (152 mm) above the floor. Factory-furnished wall brackets make installation easy.

Thermal Protection – A linear limit, automatic reset thermal cutout is built into every unit.

Complete Electrical Package – For larger single-phase and all three-phase units, a built-on contactor and transformer option package are available.

• Wide Selection of Sizes: Four compact sizes to fit any space with ratings from 500 to 9,500 watts.

• Sloped Top Cabinet: Prevents objects from being set on top of the convector, which can restrict airflow and cause overheating.

• Single and Three-Phase: Unique design provides single and balanced three-phase loads in a single element.

• Gas and Dust Atmospheres: Three listings cover the entire field, two for hazardous gases and vapors and one for dust particles.

• Wet Locations: All unit sizes available with iridite- coat-ed elements and powder-coated frames for NEMA 3 wet locations.

Heatrex’s explosion-proof convector is designed to provide a heavy duty and corrosion resistant heat source. Features include:

Applications• Battery Storage Areas

• Chemical Plants

• Coal Handling Facilities

• Dry Cleaning Plants

• Gasoline Fueling/Storage Areas

• Grain Elevators

• Oil Refineries

• Paint Spraying/Storage Areas

• Petrochemical Plants

American Bureau of Shipping

Class I, Divisions 1 and 2, Groups B, C and DClass II, Divisions 1 and 2, Groups E, F and GClass I, Zones 1 and 2, Groups IIB and H2

Page 21: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

20

254 Series Convector

All single-phase heaters rated over 22 amps or 277 volts and all three-phase heaters require a magnetic contactor. Some electrical combinations will also require a control transformer.

To simplify field installation, these accessories are facto-ry-mounted on the heater cabinet and factory pre-wired (not available on Size 1 convectors).

Electrical Package Options

Custom Option

Code Option Description AvailabilityCode (2)

B2 Electric Control Option (1)(without thermostat)

Classes I and II, Groups B, C, E, D, F and G includes contactor and trans-former (as required). Required for all three-phase and single- phase heaters over 22 amps or 277 volts

AS

B2S1 Thermostat & Controls (1) Classes I and II, Groups C, D, E, F and G includes thermostat, contactor and transformer (as required). AS

B3 Thermostat & Controls(Group B) (1)

Classes I and II, Groups B, C, D, E, F and G includes thermostat, contac-tor and transformer (as required). Thermostat has internal set point. AS

S1 Thermostat Only (1)Classes I and II, Groups C, D, E, F and G single-phase heaters rated up to 22 amps at 120-277 volts. Use remote room thermostat Catalog Num-ber 1007002 for Size 1 convectors.

AS

S2 Thermostat Only (Group B) (1)

Classes I and II, Groups B, C, D, E, F and G single-phase heaters rated up to 22 amps at 120-277 volts. Thermostat has internal set point. Use re-mote room thermostat Catalog Number 1024754 for Size 1 convectors.

AS

Code Option Description AvailabilityCode (2)

C1 Wet Locations Type 3 rated construction. Includes Iridite coated element assembly and gasketed terminal box. Not available with options B2/S1, S1, or S2. C

C2Corrosive-Resistant Stainless Steel Construction

Type 3 rated construction with addition of stainless steel cabinet. In-cludes Iridite coated element assembly and gasketed terminal box. Not available with options B2/S1, S1, or S2. ONLY the cabinet is upgraded to stainless steel.

C

(1) These options are not available on Size 1 Convectors.

(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.

Accessory Remote ThermostatCatalog Number Switch Type Description Type Ratings

Temp.RangeoF (oC)

Availability Code

1007002 Bimetal Class 1, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G SPDT 125-277V,

22A50-90

(10-32)

AS1024754 Bulb and Capillary with Internal Set Point Adjustment

Class 1, Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G SPDT

120-240V,25A

277V, 22A

40-120(5-49)

1025396 Bulb and Capillary with Internal Set Point Adjustment

Corrosion-Resistant Class 1, Div. 1,Groups B, C, & D

Class II, Div. 1, Groups E, F & GSPST

120-240V,25A

277V, 22A

40-120(5-49)

Page 22: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

21

254 Series Convector

Class I, Divisions 1 & 2, Groups B, C & D Ignition Temperature Code T2A, 536⁰F (280⁰C)Class I, Zones 1 and 2 Groups IIB + H2Use these heaters when ordering heaters without optional built-on controls

KW Volts (1) Phase Total

AmpsUnit Size

Catalog Number

Availability Code (3)

Optional Built-on Controls

Controls Only

Thermostat Only (3) or

Thermostat with Controls

0.5

120 1 4.2

1

HX-254-F0310052B

AS

N/A 1024754208 1 2.4 HX-254-F0310052C N/A 1024754240 1 2.1 HX-254-F0310052J N/A 1024754277 1 1.8 HX-254-F0310052N N/A 1024754

1

120 1 8.3

1

HX-254-F0310102B N/A 1024754208 1 4.8 HX-254-F0310102C N/A 1024754240 1 4.2 HX-254-F0310102J N/A 1024754277 1 3.6 HX-254-F0310102N N/A 1024754

1.8

120 1 15.0

2

HX-254-F0320182B N/R S2208 1 8.7 HX-254-F0320182C N/R S2240 1 7.5 HX-254-F0320182J N/R S2277 1 6.5 HX-254-F0320182N N/R S2347 1 5.2 HX-254-F0320182I B2 B3480 3 2.2 HX-254-F0320182U B2 B3600 3 1.8 HX-254-F0320182Z B2 B3

2.5

208 1 12.0

2

HX-254-F0320252C N/R S2208 3 6.9 HX-254-F0320252D B2 B3240 1 10.4 HX-254-F0320252J N/R S2277 1 9.0 HX-254-F0320252N N/R S2347 1 7.2 HX-254-F0320252I B2 B3480 3 3.0 HX-254-F0320252U B2 B3600 3 2.4 HX-254-F0320252Z B2 B3

3.6

208 1 17.3

3

HX-254-F0330362C N/R S2208 3 10.0 HX-254-F0330362D B2 B3240 1 15.0 HX-254-F0330362J N/R S2277 1 13.0 HX-254-F0330362N N/R S2347 1 10.4 HX-254-F0330362I B2 B3480 3 4.3 HX-254-F0330362U B2 B3600 3 3.5 HX-254-F0330362Z B2 B3

4.4

208 3 12.2

3

HX-254-F0330442D B2 B3240 1 18.3 HX-254-F0330442J N/R S2277 1 15.9 HX-254-F0330442N N/R S2347 1 12.7 HX-254-F0330442I B2 B3480 3 5.3 HX-254-F0330442U B2 B3600 3 4.3 HX-254-F0330442Z B2 B3

6.5

208 3 18.0

4

HX-254-F0340652D B2 B3240 3 27.1 HX-254-F0340652J B2 B3277 1 23.5 HX-254-F0340652N B2 B3347 1 18.7 HX-254-F0340652I B2 B3480 3 7.8 HX-254-F0340652U B2 B3600 3 6.3 HX-254-F0340652Z B2 B3

7.5

208 3 20.8

4

HX-254-F0340752D B2 B3240 1 31.3 HX-254-F0340752JH B2 B3277 1 27.1 HX-254-F0340752N B2 B3347 1 21.6 HX-254-F0340752I B2 B3480 3 9.0 HX-254-F0340752U B2 B3600 3 7.2 HX-254-F0340752Z B2 B3

9.5

208 3 26.4

4

HX-254-F0340952D B2 B3240 1 39.6 HX-254-F0340952J B2 B3277 1 34.3 HX-254-F0340952N B2 B3347 1 27.4 HX-254-F0340952I B2 B3480 3 11.4 HX-254-F0340952U B2 B3600 3 9.1 HX-254-F0340952Z B2 B3

(1) Convectors are 60/50 Hz rated(2) AS = Assembly Stock, AS listed heaters ordered with custom (C) features are subject to longer lead times.(3) Thermostat only is load carrying or remote.

Page 23: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

22

254 Series Convector

KW Volts (1) 3Phase Total

AmpsUnit Size

Catalog Number

Availability Code (3)

Optional Built-on Controls

Controls Only

Thermostat Only (3) or

Thermostat with Controls

0.5

120 1 4.2

1

HX-254-F0310053B

AS

N/A 1007002208 1 2.4 HX-254-F0310053C N/A 1007002240 1 2.1 HX-254-F0310053J N/A 1007002277 1 1.8 HX-254-F0310053N N/A 1007002

1

120 1 8.3

1

HX-254-F0310103B N/A 1007002208 1 4.8 HX-254-F0310103C N/A 1007002240 1 4.2 HX-254-F0310103J N/A 1007002277 1 3.6 HX-254-F0310103N N/A 1007002

1.8

120 1 15.0

2

HX-254-F0320183B N/R S1208 1 8.7 HX-254-F0320183C N/R S1240 1 7.5 HX-254-F0320183J N/R S1277 1 6.5 HX-254-F0320183N N/R S1347 1 5.2 HX-254-F0320183I B2 B2S1480 3 2.2 HX-254-F0320183U B2 B2S1600 3 1.8 HX-254-F0320183Z B2 B2S1

2.5

208 1 12.0

2

HX-254-F0320253C N/R S1208 3 6.9 HX-254-F0320253D B2 B2S1240 1 10.4 HX-254-F0320253J N/R S1277 1 9.0 HX-254-F0320253N N/R S1347 1 7.2 HX-254-F0320253I B2 B2S1480 3 3.0 HX-254-F0320253U B2 B2S1600 3 2.4 HX-254-F0320253Z B2 B2S1

3.6

208 1 17.3

3

HX-254-F0330363C N/R S1208 3 10.0 HX-254-F0330363D B2 B2S1240 1 15.0 HX-254-F0330363J N/R S1277 1 13.0 HX-254-F0330363N N/R S1347 1 10.4 HX-254-F0330363I B3 B3S1480 3 4.3 HX-254-F0330363U B2 B2S1600 3 3.5 HX-254-F0330363Z B2 B2S1

4.4

208 3 12.2

3

HX-254-F0330443D B2 B2S1240 1 18.3 HX-254-F0330443J N/R S1277 1 15.9 HX-254-F0330443N N/R S1347 1 12.7 HX-254-F0330443I B2 B3S1480 3 5.3 HX-254-F0330443U B2 B2S1600 3 4.3 HX-254-F0330443Z B2 B2S1

6.5

208 3 18.0

4

HX-254-F0340653D B2 B2S1240 1 27.1 HX-254-F0340653J B2 B2S1277 1 23.5 HX-254-F0340653N B2 B2S1347 1 18.7 HX-254-F0340653I B2 B2S1480 3 7.8 HX-254-F0340653U B2 B2S1600 3 6.3 HX-254-F0340653Z B2 B2S1

7.5

208 3 20.8

4

HX-254-F0340753D B2 B2S1240 1 31.3 HX-254-F0340753J B2 B2S1277 1 27.1 HX-254-F0340753N B2 B2S1347 1 21.6 HX-254-F0340753I B2 B2S1480 3 9.0 HX-254-F0340753U B2 B2S1600 3 7.2 HX-254-F0340753Z B2 B2S1

9.5

208 3 26.4

4

HX-254-F0340953D B2 B2S1240 1 39.6 HX-254-F0340953J B2 B2S1277 1 34.3 HX-254-F0340953N B2 B2S1347 1 27.4 HX-254-F0340953I B2 B2S1480 3 11.4 HX-254-F0340953U B2 B2S1600 3 9.1 HX-254-F0340953Z B2 B2S1

Class I, Divisions 1 & 2, Groups C & D Class I, Zones 1 and 2 Groups IIBIgnition Temperature Code T2A, 536⁰F (280⁰C)

(1) Convectors are 60/50 Hz rated(2) AS = Assembly Stock, AS listed heaters ordered with custom (C) features are subject to longer lead times.(3) Thermostat only is load carrying or remote.

Page 24: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

23

254 Series Convector

Class I, Divisions 1 & 2, Groups B, C & D Ignition Temperature Code T3A, 356⁰F (180⁰C)Class I, Zones 1 and 2 Groups IIB + H2Use these heaters when ordering heaters without optional built-on controls

KW Volts (1) Phase Total

AmpsUnit Size

Catalog Number

Availability Code (3)

Optional Built-on Controls

Controls Only

Thermostat Only (3) or

Thermostat with Controls

0.5

120 1 4.2

1

HX-254-F0610052B

AS

N/A 1024754

208 1 2.4 HX-254-F0610052C N/A 1024754

240 1 2.1 HX-254-F0610052J N/A 1024754

277 1 1.8 HX-254-F0610052N N/A 1024754

1.4

120 1 11.7

2

HX-254-F0620142B N/R S2

208 1 6.7 HX-254-F0620142C N/R S2

240 1 5.8 HX-254-F0620142J N/R S2

277 1 5.1 HX-254-F0620142N N/R S2

347 1 4.0 HX-254-F0620142I B2 B3

2.3

120 1 19.2

3

HX-254-F0630232B N/R S2

208 1 11.1 HX-254-F0630232C N/R S2

208 3 6.4 HX-254-F0630232D B2 B3

240 1 9.6 HX-254-F0630232J N/R S2

277 1 8.3 HX-254-F0630232N N/R S2

347 1 6.6 HX-254-F0630232I B2 B3

480 3 2.8 HX-254-F0630232U B2 B3

600 3 2.2 HX-254-F0630232Z B2 B3

3.2

208 1 15.4

4

HX-254-F0640322C N/R S2

208 3 8.9 HX-254-F0640322D B2 B3

240 1 13.3 HX-254-F0640322J N/R S2

277 1 11.6 HX-254-F0640322N N/R S2

347 1 9.2 HX-254-F0640322I B2 B3

480 3 3.8 HX-254-F0640322U B2 B3

600 3 3.1 HX-254-F0640322Z B2 B3

5.0

208 3 13.9

4

HX-254-F0640502D B2 B3

240 1 20.8 HX-254-F0640502J N/R S2

277 1 18.1 HX-254-F0640502N N/R S2

347 1 14.4 HX-254-F0640502I B2 B3

480 3 6.0 HX-254-F0640502U B2 B3

600 3 4.8 HX-254-F0640502Z B2 B3(1) Convectors are 60/50 Hz rated(2) AS = Assembly Stock, AS listed heaters ordered with custom (C) features are subject to longer lead times.(3) Thermostat only is load carrying or remote.

Page 25: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

24

254 Series Convector

KW Volts (1) Phase Total

AmpsUnit Size

Catalog Number

Availability Code (3)

Optional Built-on Controls

Controls Only

Thermostat Only (3) or

Thermostat with Controls

0.5

120 1 4.2

1

HX-254-F0610053B

AS

N/A 1007002

208 1 2.4 HX-254-F0610053C N/A 1007002

240 1 2.1 HX-254-F0610053J N/A 1007002

277 1 1.8 HX-254-F0610053N N/A 1007002

1.4

120 1 11.7

2

HX-254-F0620143B N/R S1

208 1 6.7 HX-254-F0620143C N/R S1

240 1 5.8 HX-254-F0620143J N/R S1

277 1 5.1 HX-254-F0620143N N/R S1

347 1 4.0 HX-254-F0620143I B2 B2S1

2.3

120 1 19.2

3

HX-254-F0630233B N/R S1

208 1 11.1 HX-254-F0630233C N/R S1

208 3 6.4 HX-254-F0630233D B2 B2S1

240 1 9.6 HX-254-F0630233J N/R S1

277 1 8.3 HX-254-F0630233N N/R S1

347 1 6.6 HX-254-F0630233I B2 B2S1

480 3 2.8 HX-254-F0630233U B2 B2S1

600 3 2.2 HX-254-F0630233Z B2 B2S1

3.2

208 1 15.4

4

HX-254-F0640323C N/R S1

208 3 8.9 HX-254-F0640323D B2 B2S1

240 1 13.3 HX-254-F0640323J N/R S1

277 1 11.6 HX-254-F0640323N N/R S1

347 1 9.2 HX-254-F0640323I B2 B2S1

480 3 3.8 HX-254-F0640323U B2 B2S1

600 3 3.1 HX-254-F0640323Z B2 B2S1

5.0

208 3 13.9

4

HX-254-F0640503D B2 B2S1

240 1 20.8 HX-254-F0640503J N/R S1

277 1 18.1 HX-254-F0640503N N/R S1

347 1 14.4 HX-254-F0640503I B2 B2S1

480 3 6.0 HX-254-F0640503U B2 B2S1

600 3 4.8 HX-254-F0640503Z B2 B2S1

Class I, Divisions 1 & 2, Groups C & D Class I, Zones 1 and 2 Groups IIBIgnition Temperature Code T3A, 356⁰F (180⁰C)

(1) Convectors are 60/50 Hz rated(2) AS = Assembly Stock, AS listed heaters ordered with custom (C) features are subject to longer lead times.(3) Thermostat only is load carrying or remote.

Page 26: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

25

254 Series Convector

Accessory Remote Thermostat

(1) Convectors are 60/50 Hz rated(2) AS = Assembly Stock, AS listed heaters ordered with custom (C) features are subject to longer lead times.(3) Thermostat only is load carrying or remote.

Class II, Divisions 1 & 2, Groups E, F & G Ignition Temperature Code T3C, 320⁰F (160⁰C)

KW Volts (1) Phase Total

AmpsUnit Size

Catalog Number

Availability Code (3)

Optional Built-on Controls

Controls Only

Thermostat Only (3) or

Thermostat with Controls

0.5

120 1 4.2

1

HX-254-F0810054B

AS

N/A 1007002

208 1 2.4 HX-254-F0810054C N/A 1007002

240 1 2.1 HX-254-F0810054J N/A 1007002

277 1 1.8 HX-254-F0810054N N/A 1007002

1.0

120 1 8.3

2

HX-254-F0820104B N/R S1

208 1 4.8 HX-254-F0820104C N/R S1

240 1 4.2 HX-254-F0820104J N/R S1

277 1 3.6 HX-254-F0820104N N/R S1

347 1 2.9 HX-254-F0820104I B2 B2S1

1.7

120 1 14.2

3

HX-254-F0830174B N/R S1

208 1 8.2 HX-254-F0830174C N/R S1

208 3 4.7 HX-254-F0830174D B2 B2S1

240 1 7.1 HX-254-F0830174J N/R S1

277 1 6.1 HX-254-F0830174N N/R S1

347 1 4.9 HX-254-F0830174I B2 B2S1

480 3 2 HX-254-F0830174U B2 B2S1

600 3 1.6 HX-254-F0830174Z B2 B2S1

3.2

208 1 15.4

4

HX-254-F0840324C N/R S1

208 3 8.9 HX-254-F0840324D B2 B2S1

240 1 13.3 HX-254-F0840324J N/R S1

277 1 11.6 HX-254-F0840324N N/R S1

347 1 9.2 HX-254-F0840324I B2 B2S1

480 3 3.8 HX-254-F0840324U B2 B2S1

600 3 3.1 HX-254-F0840324Z B2 B2S1

Catalog Number Switch Type Description Type Ratings

Temp.RangeoF (oC)

Availability Code

1007002 Bimetal Class 1, Div. 1, Groups C & D Class II, Div. 1, Groups E, F, & G SPDT 125-277V,

22A50-90

(10-32)

AS1024754 Bulb and Capillary with Internal Set Point Adjustment

Class 1, Div. 1, Groups B, C & D Class II, Div. 1, Groups E, F, & G SPDT

120-240V,25A

277V, 22A

40-120(5-49)

1025396 Bulb and Capillary with Internal Set Point Adjustment

Corrosion-Resistant Class 1, Div. 1,Groups B, C, & D

Class II, Div. 1, Groups E, F & GSPST

120-240V,25A

277V, 22A

40-120(5-49)

Page 27: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

26

254 Series Convector

7.50

Thermostat (External Set Point)

Optional Built-onThermostat (External Set Point)

ControlPackage

ControlPackagew/ Thermostat (Internal Set Point)

Thermostat (External Set Point)

9.00

3.44

7.50

Thermostat is rated for Class I, Groups C and DClass II Groups E, F and G

Thermostat is rated for Class I, Groups C and DClass II Groups E, F and G

Thermostat is rated for Class I, Groups B, C and DClass II Groups E, F and G

Thermostat is rated for Class I, Groups B, C and DClass II Groups E, F and G

Option S1

Option B2S1 Option B3

Option S2

7.50 7.50

Dimensions and Weights

Unit SizeDimensions - In. (cm) Weight - Lb (kg)

Length (L) Height (H) Depth (D) Without Controls

1 26 (66) 6 (15) 4-1/2 (11) 13 (5.9)2 26 (66) 16 (41) 8 (20) 27 (12.2)3 39 (99) 16 (41) 8 (20) 36 (16.3)4 67-1/2 (171) 16 (41) 8 (20) 60 (27.2)

Page 28: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

27

Comparison Chart

234

240926

238

928

Features 234 Series 238 Series 240 Series 926 Series 928 Series

TypicalApplications

Food processing plants

Marine duty

Wastewatertreatment plants

Factories

Warehouses

Factories

Mechanicalrooms

Workshops

Mechanicalrooms

Warehouses

Workshops

Gyms

High bay areas

Warehouses

KW Range 2 to 47 3 to 38.4 3.3 to 50 2 to 60 5 to 30

Voltages up to 600/3 Up to 480/3 Up to 480/3 Up to 480/3 Up to 480/3

Airflow CFM Up to 2400 Up to 1774 Up to 3100 Up to 2000 Up to 2300

Discharge Horizontal Horizontal Horizontal orVertical

Horizontal orVertical Vertical

Element Type Stainless steelfinned tubular

Stainless steelfinned tubular

Stainless steelfinned tubular

Stainless steel tubular or steel finned

tubular

Steel finned tubular

StandardConstruction

16 gauge stainless steel shroud and non-

metallic NEMA 4X control enclosure

16 gauge galvanized steel shroud and control enclosure

20-14 gauge(depending on size)

galvanized steel cabinet

8 & 20 gauge steel cabinet

18 gauge galvanized steel cabinet

Finish Stainless steel Beige polyesterpowder paint

Camel polyester powder paint

Almondpolyester

powder paint

Almondpolyester

powder paint

Mounting Ceiling or wall Ceiling or wall Ceiling or wall Ceiling or wall Ceiling

AgencyApprovals cULus & ABS cULus cULus CSAus CSA

Page 29: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

28

The Heatrex 234 Series unit heater is the perfect solution to the problem of heating people or equipment in non-hazardous environments where moisture and corrosion exist. Advantages of the 234 Series include:

• Built-in Controls: All necessary safety and temperature controls are included in a single package. Components and motor are factory-wired to a single terminal block for field wiring, eliminating the chance for field error and reducing installation costs.

• Single Point Electrical Hook-up: Heater, fan motor and con-trols are all connected to the same branch circuit.

• Corrosion Resistant: Stainless steel construction, powder- coated aluminum fan blade and nonmetallic NEMA 4X terminal enclosure resist corrosion found in sewage treatment plants, swimming pool areas, car washes, paper mills and marine installations.

• Washable: This watertight construction can be hosed down without disconnecting the heater, which makes it ideal for coal handling areas, steel mills, foundries, ships, wood finish-ing plants, cement, sand, grain and food processing facilities.

Applications• Car Washes

• Cement Plants

• Coal Handling Areas

• Dairies

• Food Processing Plants

Standard Construction FeaturesHeating Elements – Industrial grade, Type 316 stainless steel tubular elements with stainless steel fins, manufactured by Heatrex.

Fan Motor Assembly – Totally enclosed, epoxy coated, UL Recognized motor with permanently lubricated ball bearings for longer life. Designed to resist moisture and corrosion. Factory-wired to NEMA 4X enclosure. Fitted with a powder- coated, aluminum fan blade suitable for corrosive salt spray environments.

Housing – Heating elements and motor are enclosed in a round, heavy 16-gauge 304 stainless steel shroud.

Inlet/Outlet Grilles – Adjustable, stainless steel, louvered outlet grille can be rotated 90° to direct airflow up, down, left or right. Heavy gauge, 304 stainless steel rear grille protects against accidental contact with the fan blade.

Control Enclosure – The non-metallic enclosure, which houses the element terminals and built-in controls, will not rust and meets NEMA 4X hose-down requirements.

Built-in Controls – Include automatic reset overtemperature cutout, fan delay relay, controlling contactor, transformer for 24-volt control circuit, terminal block for field wiring and a separate motor contactor (when required).

Mounting Bracket – The heater comes complete with a 304 stainless steel swivel mounting bracket which can be used either for wall or ceiling mounting. Four field-supplied 3/8-16 threaded rods can also be used for ceiling installation.

American Bureau of Shipping

• Marine and Offshore

• Power Generating Stations

• Steel Mills and Foundries

• Swimming Pool Areas

• Wastewater Treatment Plants

234 SeriesWashdown/Corrosion Resistant Unit Heater

Page 30: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

29

234 SeriesWashdown/Corrosion Resistant Unit Heater

Factory Built-in Options

Code Description AvailabilityCode (2)

B Delete swivel mounting bracket. Heater installs from the ceiling with field furnished threaded rods. AS

C Epoxy painted stainless steel parts, housing, grilles and fan blade C

D Power disconnect switch AS

E Monel finned tubular elements C

F8 Fan motor fusing with disconnecting contactor C

L “Heater on” pilot light AS

M Secondary manual reset overtemperature cutout. Required for U.S. Coast Guard and ABS Approved designs. AS

S Three-position selector switch (heater-standby-fan) AS

T1- Stage Built-in thermostat 40 to 100° F (5 to 38° C) range AS

2- Stage Built-in thermostat 40 to 120° F (5 to 49° C) range (Option “X” required) C

V 120 volt control circuit AS

X 2-Stage Control C

(2) AS = Assembly Stock, C = Custom. Assembly Stock heaters ordered with custom options are subject to longer delivery.

Remote Room Thermostat

1004328 1026347

Catalog Number

Switch Type Ratings Type Tamper-

proofThermo-

meter Amps PilotDuty

Tempera-ture Range

oF (oC)

1004328 Bulb NEMA 4X SPDT No No 25A @ 120-240V22A @ 277V 125VA 40-110

(5-43)

1026347 2-StageBulb NEMA 4X 2 SPDT No No 25A @ 120-240V

22A @ 277V 125VA 40-100(5-38)

Page 31: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

30

234 SeriesWashdown/Corrosion Resistant Unit Heater

Dimensions, Airflow and Weights

Dimensions, Airflows and WeightsKW

2 - 7.5 9 - 12 12.5 - 47

OverallHeaterDimensions

“X” Inch (cm) 15-1/2 (39) 15-1/2 (39) 26 (66)“Y” Inch (cm) 21-1/2 (55) 21-1/2 (55) 28 (71)“Z” Inch (cm) 13 (33) 13 (33) 20 (51)

MountingHoleDimensions

“BH” Inch (cm) 4-1/4 (11) 4-1/4 (11) 7-1/8 (18)“BL” Inch (cm) 19-1/2 (50) 19-1/2 (50) 22-1/4 (57)“M” Inch (cm) 8-1/2 (22) 8-1/2 (22) 3-1/4 (8)

AirflowCharacteristics

Air Volume CFM (cubic meters/hr) 700 (1189) 1450 (2463) 2400 (4077)Air Throw Feet (m) 26 (8) 43 (13) 50 (15)

Outlet Velocity FPM (meters/min) 760 (232) 1575 (481) 1200 (366)

WeightNet Lbs (kgs) 56 (25) 56 (25) 115 (52)

Shipping Lbs (kgs) 70 (32) 70 (32) 130 (60)

CONDUIT OPENINGFOR FIELD WIRING

AIRFLOW

SWIVEL BRACKET(WALL MOUNTING)

SWIVELBRACKET(CEILINGMTG)

FOUR 3/8 - 16 THREADED RODS (NOT SUPPLIED WITH THE HEATER)

FLOOR

CEILING

WAL

L

WAL

L

WAL

L

6’ MIN(ANY MOUNTING)

M

8”MIN

BLBH

8”MIN

Z

Y

8”MIN

8”MIN

X

Page 32: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

31

234 SeriesWashdown/Corrosion Resistant Unit Heater

234 Series Unit Heater Listing

(1) Total Amps = Heating ele-ment amps and motor amps.(2) Availability Code: AS = Assembly Stock,(3) Stock heaters ordered with custom options subject to longer delivery.

NOTE: 2-Stage heaters can be field wired as single stage.1A = Optional 2-stage control, unbalanced (option ‘X’).1B = Optional 2-stage control, balanced (option ‘X’)

For Non-Hazardous Areas

KW Volts PhTotalAmps

(1)

Approximate Air Temperature Rise

°F (°C)

Motor CatalogNumber

2-StageControl

AvailabilityCode (2)(3)HP Volts Ph

2

120 1 21 9 (5) 1/4 120 1 HX-234-U11R-0020B 1B

AS

208 1 12 9 (5) 1/4 208 1 HX-234-U11R-0020C 1B240 1 11 9 (5) 1/4 240 1 HX-234-U11R-0020J 1B277 1 10 9 (5) 1/4 277 1 HX-234-U11R-0020N 1B

3

120 1 29 14 (8) 1/4 120 1 HX-234-U11N-0030B 1B208 1 17 14 (8) 1/4 208 1 HX-234-U11N-0030C 1B240 1 15 14 (8) 1/4 240 1 HX-234-U11N-0030J 1B277 1 13 14 (8) 1/4 277 1 HX-234-U11N-0030N 1B480 1 8 14 (8) 1/4 480 1 HX-234-U11N-0030T 1B208 3 11 14 (8) 1/4 208 1 HX-234-U11N-0030D 1A240 3 10 14 (8) 1/4 240 1 HX-234-U11N-0030K 1A480 3 5 14 (8) 1/4 480 1 HX-234-U11N-0030U 1A600 3 4 14 (8) 1/4 600 1 HX-234-U11N-0030Z 1A

5

208 1 27 24 (13) 1/4 208 1 HX-234-U11R-0050C 1B240 1 23 24 (13) 1/4 240 1 HX-234-U11R-0050J 1B277 1 20 24 (13) 1/4 277 1 HX-234-U11R-0050N 1B480 1 12 24 (13) 1/4 480 1 HX-234-U11R-0050T 1B208 3 16 24 (13) 1/4 208 1 HX-234-U11N-0050D 1A240 3 15 24 (13) 1/4 240 1 HX-234-U11N-0050K 1A480 3 8 24 (13) 1/4 480 1 HX-234-U11N-0050U 1A600 3 6 24 (13) 1/4 600 1 HX-234-U11N-0050Z 1A

7.5

208 1 39 35 (19) 1/4 208 1 HX-234-U11N-0080C 1B240 1 34 35 (19) 1/4 240 1 HX-234-U11N-0080J 1B277 1 29 35 (19) 1/4 277 1 HX-234-U11N-0080N 1B480 1 17 35 (19) 1/4 480 1 HX-234-U11N-0080T 1B208 3 23 35 (19) 1/4 208 1 HX-234-U11N-0080D 1A240 3 21 35 (19) 1/4 240 1 HX-234-U11N-0080K 1A480 3 11 35 (19) 1/4 480 1 HX-234-U11N-0080U 1A600 3 9 35 (19) 1/4 600 1 HX-234-U11N-0080Z 1A

9

208 1 46 20 (11) 1/4 208 1 HX-234-U11N-0090C 1B240 1 40 20 (11) 1/4 240 1 HX-234-U11N-0090J 1B277 1 35 20 (11) 1/4 277 1 HX-234-U11N-0090N 1B480 1 20 20 (11) 1/4 480 1 HX-234-U11N-0090T 1B208 3 28 20 (11) 1/4 208 1 HX-234-U11N-0090D 1A240 3 24 20 (11) 1/4 240 1 HX-234-U11N-0090K 1A480 3 12 20 (11) 1/4 480 1 HX-234-U11N-0090U 1A600 3 10 20 (11) 1/4 600 1 HX-234-U11N-0090Z 1A

10

240 1 44 22 (12) 1/4 240 1 HX-234-U11N-0100J 1B277 1 39 22 (12) 1/4 277 1 HX-234-U11N-0100N 1B480 1 22 22 (12) 1/4 480 1 HX-234-U11N-0100T 1B208 3 30 22 (12) 1/4 208 1 HX-234-U11N-0100D 1A240 3 27 22 (12) 1/4 240 1 HX-234-U11N-0100K 1A480 3 14 22 (12) 1/4 480 1 HX-234-U11N-0100U 1A600 3 11 22 (12) 1/4 600 1 HX-234-U11N-0100Z 1A

12

277 1 46 26 (14) 1/4 277 1 HX-234-U11N-0120N 1A480 1 27 26 (14) 1/4 480 1 HX-234-U11N-0120T 1B208 3 36 26 (14) 1/4 208 1 HX-234-U11N-0120D 1A240 3 32 26 (14) 1/4 240 1 HX-234-U11N-0120K 1A480 3 16 26 (14) 1/4 480 1 HX-234-U11N-0120U 1A600 3 13 26 (14) 1/4 600 1 HX-234-U11N-0120Z 1A

12.5

208 3 37 17 (9) 1/4 208 1 HX-234-U11L-0130D 1A240 3 33 17 (9) 1/4 240 1 HX-234-U11L-0130K 1A480 3 17 17 (9) 1/4 480 1 HX-234-U11L-0130U 1A600 3 14 17 (9) 1/4 600 1 HX-234-U11L-0130Z 1A

15

208 3 44 21 (12) 1/4 208 1 HX-234-U11L-0150D 1A240 3 39 21 (12) 1/4 240 1 HX-234-U11L-0150K 1A480 3 20 21 (12) 1/4 480 1 HX-234-U11L-0150U 1A600 3 16 21 (12) 1/4 600 1 HX-234-U11L-0150Z 1A

20 480 3 26 28 (16) 1/4 480 1 HX-234-U11L-0200U 1A600 3 21 28 (16) 1/4 600 1 HX-234-U11L-0200Z 1A

25 480 3 32 35 (19) 1/4 480 1 HX-234-U11A-0250U 1B600 3 26 35 (19) 1/4 600 1 HX-234-U11A-0250Z 1B

30 480 3 38 42 (23) 1/4 480 1 HX-234-U11A-0300U 1B600 3 31 42 (23) 1/4 600 1 HX-234-U11A-0300Z 1B

35 480 3 44 48 (27) 1/4 480 1 HX-234-U11A-0350U 1B600 3 35 48 (27) 1/4 600 1 HX-234-U11A-0350Z 1B

38.4 480 3 48 54 (30) 1/4 480 1 HX-234-U11A-0390U 1B600 3 38 54 (30) 1/4 600 1 HX-234-U11A-0390Z 1B

47 600 3 47 64 (36) 1/4 600 1 HX-234-U11A-0470Z 1B

Page 33: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

32

Heatrex’s industrial unit heater is designed for max-imum heating performance in non-hazardous and non-corrosive environments. Features include:

• Unique Design: Round design of the industrial unit heater provides uniform airflow over the elements to prevent hot spots and ensure even discharge temperatures. Circular stainless steel finned tubular elements have a longer life due to lower operating temperatures.

• Built-in Controls: Heaters are completely assembled with all electrical components built-in at the factory to reduce installation costs.

• Improved Performance: High CFM’s and air throw up to 50 feet promote air circulation within the space. More uniform temperature increases comfort levels and helps to eliminate cold spots.

• Single Point Electrical Hook-up: Heater, fan motor and controls are all connected to the same branch circuit.

Standard Construction FeaturesHeating Elements – Industrial grade, Type 304 stainless steel finned tubular elements, manufactured by Heatrex.

Housing – Heating elements and motor are enclosed in a round, 16-gauge galvanized steel enclosure which has a beige powder coat finish for durability.

Inlet/Outlet Grilles – Inlet grille complies with OSHA require-ments for fan blade guard. Outlet grille has 45° beige powder coat finish angled louvers to direct airflow.

Fan Motor – Motor is UL Recognized with built-in thermal protection.

Built-in Controls – Include main control magnetic contactor, 24V control voltage transformer, automatic reset thermal cutout and fan thermostat.

Mounting Bracket – Wall mounting bracket with single point suspension allows the heater to rotate a full 360°.

• Power Generating Stations

• Pump Houses

• Service Stations

Thermostats

Applications• Aircraft Hangars

• Entryways

• Factories

• Garages

Catalog Number

Switch Type Color Type Tamper-

proofThermo-

meter

Amps @ 120-240V

Amps @

277V

Pilot Duty

Positive Off

TemperatureRange oF

1006998 Bimetal White SPDT No No — — 30VA at 30V max Yes 50-90

238 SeriesIndustrial Unit Heater

Page 34: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

33

238 SeriesIndustrial Unit Heater

Dimensions, Weights and Air Throws

Motor Data

Factory Built-in Options

Code Description AvailabilityCode (2)

B No mounting bracket ASC Substitute wall mounting bracket with ceiling bracket (beige powder coat finish for durability) ASD Power Disconnect Switch ASG Adjustable Outlet Louvers (beige powder coat finish for durability) ASH Premium Fan Motor ASL “Heater On” Pilot Light ASM Secondary Manual Reset Thermal Cutout ASR Built-in Fan Relay - Required for Remote Fan Switch ASS Three-position Selector Switch (Heater-Standby-Fan) AST Built-in Thermostat 40° to 120° F (4° to 49° C) Range ASX No Transformer - Customer supplied control voltage AS

KWDimensions - In. (cm) Weight

Lb (kgs)Maximum AirThrow-Ft. (m)M W X Y Z

1 - 12 8-1/4 (21) 8-3/4 (22) 15 (38) 17 (43) 13 (41) 45 (20) 15 (5)

12.5 - 20 7 (18) 5-1/2 (14) 16-1/4 (41) 23-1/2 (60) 19-1/4 (49) 60 (27) 50 (15)

25 - 38.4 4 (10) 5-1/2 (14) 20-3/4 (53) 23-1/2 (60) 19-1/4 (49) 80 (36) 50 (15)

Description RPMAirflow - CFM (cubic meters/hr) Noise Level (dB)

3-12 KW 12.5-20 KW 25-38.4 KW 3-12 KW 12.5-20 KW 25-38.4 KW

Standard 1200 362 (615) 1342 (2280) 1237 (2102) 64 68 68

Premium 1800 618 (1050) 1774 (3014) 1635 (2778) 75 84 84

AccessMaintenance

2 Ft.Minimum

6 In.

Y

X Z

(any mounting)Minimum to floor

6 Ft.

CEILING

WA

LL

WA

LL

heater) with the (not suppliedthreaded rods Two 3/8-16

mounting bracketCeiling

bracketWall mounting

WMinimum

Airflow

Minimum W

Mini

mum - M

(2) AS = Assembly Stock, C = Custom. Assembly stock heaters ordered with custom options subject to longer delivery.

Page 35: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

34

238 SeriesIndustrial Unit Heater

Heater Listing

* Premium motor comes standard with heater.(1) Total Amps = Heating element amps and motor amps.(2) AS = Assembly Stock, C = Custom. Assembly stock heaters ordered with custom options subject to longer delivery.

For Non-Hazardous AreasFor Non-Corrosive Areas

KW Volts Phase TotalAmps (1)

Approximate AirTemperature Rise

°F (°C)

MotorCatalogNumber

AvailabilityCode (2)HP Volts Phase

3

208 1 17 21 (12) 1/4 208 1 HX-238-UT03C

AS

240 1 15 21 (12) 1/4 240 1 HX-238-UT03J480 1 8 21 (12) 1/4 480 1 HX-238-UT03T208 3 11 21 (12) 1/4 208 1 HX-238-UT03D240 3 10 21 (12) 1/4 240 1 HX-238-UT03K480 3 5 21 (12) 1/4 480 1 HX-238-UT03U

5

208 1 27 35 (19) 1/4 208 1 HX-238-UT05C240 1 23 35 (19) 1/4 240 1 HX-238-UT05J480 1 12 35 (19) 1/4 480 1 HX-238-UT05T208 3 16 35 (19) 1/4 208 1 HX-238-UT05D240 3 15 35 (19) 1/4 240 1 HX-238-UT05K480 3 8 35 (19) 1/4 480 1 HX-238-UT05U

7.5

208 1 39 53 (29) 1/4 208 1 HX-238-UT08C240 1 34 53 (29) 1/4 240 1 HX-238-UT08J480 1 17 53 (29) 1/4 480 1 HX-238-UT08T208 3 23 53 (29) 1/4 208 1 HX-238-UT08D240 3 21 53 (29) 1/4 240 1 HX-238-UT08K480 3 11 53 (29) 1/4 480 1 HX-238-UT08U

9

208 1 46 64 (36) 1/4 208 1 HX-238-UT09C240 1 40 64 (36) 1/4 240 1 HX-238-UT09J480 1 20 64 (36) 1/4 480 1 HX-238-UT09T208 3 28 64 (36) 1/4 208 1 HX-238-UT09D240 3 24 64 (36) 1/4 240 1 HX-238-UT09K480 3 12 64 (36) 1/4 480 1 HX-238-UT09U

10

240 1 44 52 (29) 1/4 240 1 *HX-238-UT10J480 1 22 52 (29) 1/4 480 1 *HX-238-UT10T208 3 30 52 (29) 1/4 208 1 *HX-238-UT10D240 3 27 52 (29) 1/4 240 1 *HX-238-UT10K480 3 14 52 (29) 1/4 480 1 *HX-238-UT10U

12

480 1 27 62 (34) 1/4 480 1 *HX-238-UT12T208 3 36 62 (34) 1/4 208 1 *HX-238-UT12D240 3 32 62 (34) 1/4 240 1 *HX-238-UT12K480 3 16 62 (34) 1/4 480 1 *HX-238-UT12U

12.5208 3 37 31 (17) 1/4 208 1 HX-238-UL13D240 3 33 31 (17) 1/4 240 1 HX-238-UL13K480 3 17 31 (17) 1/4 480 1 HX-238-UL13U

15208 3 44 38 (21) 1/4 208 1 HX-238-UL15D240 3 39 38 (21) 1/4 240 1 HX-238-UL15K480 3 20 38 (21) 1/4 480 1 HX-238-UL15U

20 480 3 26 35 (19) 1/4 480 1 *HX-238-UL20U25 480 3 32 66 (37) 1/4 480 1 HX-238-UA25U30 480 3 38 79 (44) 1/4 480 1 HX-238-UA30U35 480 3 44 61 (34) 1/4 480 1 *HX-238-UA35U

38.4 480 3 48 70 (39) 1/4 480 1 *HX-238-UA39U

Page 36: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

35

240 Series Unit Heater

Applications• Factories

• Garages

• Mechanical Rooms

• Pump Houses

• Service Areas in Air Handling Units

• Shipping and Receiving Areas

• Storage Areas

• Warehouses

• Workshops

The 240 Series unit heater is available in 50 standard mod-els with ratings up to 50 KW at voltages of 208, 240, 277, and 480 single or three-phase. They are available with a wide variety of factory built-in or field-installed options.

Temperature Control: Single-stage or two-stage control with built-in or remote-mounted thermostats are available on all heaters.

Control Options: Available as factory built-in or field-in-stalled to meet job specifications.

Custom KW’s: Custom KW’s are available up to 50 KW.

Discharge Direction: The UHIR heater can be mounted for horizontal or vertical discharge using an optional univer-sal wall/ceiling mounting bracket or with field-furnished threaded rods for ceiling mounting.

Color Options: The standard color is camel. Six optional colors are available: grey, yellow, red, white, blue or tex-tured beige. Heaters may also be supplied with unpainted corrosion resistant galvanized steel. See back cover for color samples.

Heating Elements - Industrial grade, 0.475” diameter steel sheath with brazed copper plated steel fins and epoxy sealed ends. Draw-thru airflow design pulls air across the heating ele-ments to ensure cool element operation and even air distribu-tion resulting in long element life.

Housing - Heating elements and motor are enclosed in a heavy gauge galvanized steel cabinet with a durable camel polyester powder coat finish.

Outlet Grille - Individually adjustable louvers are provided to direct airflow. A protective outlet fan guard is provided to pre-vent insertion of foreign objects.

Fan Motor - Permanently lubricated and thermally protected motor.

Built-in Controls - All units include an automatic reset thermal cutout that will de-energize the heater if an overtemperature

Standard Construction Featurescondition occurs. A manual reset thermal cutout, in addition to an automatic reset thermal cutout, is standard on heaters 10 KW and above. A fan relay is provided to allow the elements to heat up before fan startup and purges the heater of residual heat after shutdown. A 24-volt transformer and disconnecting contactor are provided on most heaters. Single-phase heaters rated at 5 KW or less have line voltage controls; 24-volt control and contactor are available. Power fusing is standard on all heaters rated over 48 amps.

Mounting – Universal horizontal or vertical discharge. Optional diffusers are available for vertical discharge. An Anemostat dif-fuser can be used to provide draft-free air movement at lower mounting heights. For higher mounting heights, radial diffuser with adjustable fins can be used to increase floor coverage or adjusted for a vertical down blast of air.

Page 37: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

36

240 Series Unit Heater

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

* consult factory for lead times(1) When specifying Option ‘P’, ‘R2’, or ‘S2’ for single-phase heaters rated up to 5KW;

Option ‘R1’ must also be specified.(2) Option ‘R2’ and ‘X’ cannot be combined on heaters rates up to 5KW.

(1) When specifying Option ‘P’, ‘R2’, or ‘S2’ for single-phase heaters rated up to 5KW; Option ‘R1’ must also be specified.

(2) Option ‘R2’ and ‘X’ cannot be combined on heaters rates up to 5KW.

Code Description

Consult Factory Custom KW - CONSULT FACTORY

D Power disconnect switch

F Fusing under 48 Amps, not available on heaters up to 10 KW

M Manual Reset Cutout (In addition to automatic cutout) on heaters up to 10KW

P (1) “Heater On” Pilot Light

R1 Built-in 24V transformer and contactor for 2.5 to 5 KW, single phase heaters.

R2 (1) (2) 120V Transformer to replace 24V Transformer

S1 Summer Fan SwitchS2 (1) Summer Fan Switch – Remote Pilot Duty

TBuilt-in Thermostat - 1 - StageBuilt-in Thermostat - 2 - Stage (Option ‘X’ required)

V1* Anemostat (Cone) DiffuserV2 Radial Diffuser

X (2) 2-Stage Control

Catalog Number Description

1024155 Anemostat (Cone) Diffuser up to 5 kW1024156 Anemostat (Cone) Diffuser over 5 kW up to 20 kW1024157 Anemostat (Cone) Diffuser over 20 kW1024152 Radial Diffuser up to 5 kW1024153 Radial Diffuser over 5 kW up to 20 kW1024154 Radial Diffuser over 20 kW1023941 Horizontal Dust Shield up to 10 kW1024059 Horizontal Dust Shield over 20 kW up to 20 kW1024060 Horizontal Dust Shield over 20 kW1024162 Disconnect Switch, 600V, Three-Pole, 32 Amp1024163 Disconnect Switch, 600V, Three-Pole, 64 Amp1024164 Disconnect Switch, 600V, Three-Pole, 80 Amp1024166 Built-in Thermostat - 1 - Stage1024167 Built-in Thermostat - 2 - Stage (Option ‘X’ required)

1024168 (1) Heater On Pilot Light (24V)1024169 (1)(2) Heater On Pilot Light (120V)

1024170 Summer Fan Switch - Built-in up to 277V1024171 Summer Fan Switch- Built-in, over 277V

1024172 (1) Summer Fan Switch - Remote, 24V Control

Vertical Mounting Air Pattern Table

Description Used onMax Mtg.

Heightft. (m)

Aft (m)

Bft (m)

WITHOUT DIFFUSERFor a straight downward air pattern, directional louvers can be removed in order to maximize airflow.

up to 5 kWover 5 up to 10 kW

over 10 up to 20 kWover 20 up to 50 kW

10 (3.0)15 (4.6)20 (6.1)25 (7.6)

17 (5.2)28 (8.5)

38 (11.6)68 (20.7)

————

DIRECTIONAL LOUVERS (standard)Provides a directional (straight line) airflow which results in a rectangular air pattern. Louvers can be adjusted through a 35 degree range of motion

up to 5 kWover 5 up to 10 kW

over 10 up to 20 kWover 20 up to 50 kW

10 (3.0)15 (4.6)20 (6.1)25 (7.6)

22 (6.7)40 (12.2)53 (16.2)85 (25.9)

12 (3.7)20 (6.1)27 (8.2)

45 (13.7)

ANEMOSTAT DIFFUSERIdeal for low mounting heights. Fabricated using 3 diverging hollow cones which disperse heat to the floor area at a minimum velocity for comfort.

up to 5 kWover 5 up to 10 kW

over 10 up to 20 kWover 20 up to 50 kW

9 (2.7)13 (4.0)17 (5.2)21 (6.4)

17 (5.2)29 (8.8)

40 (12.2)68 (20.7)

————

RADIAL DIFFUSERIdeal for high ceiling mounting. Louvers can be adjusted to direct airflow straight down when fully open to 45 degrees in a radial pattern which increases floor coverage by approxiately 20%.

OPE

N

up to 5 kWover 5 up to 10 kW

over 10 up to 20 kWover 20 up to 50 kW

10 (3.0)15 (4.6)20 (6.1)25 (7.6)

20 (6.1)30 (9.1)

38 (11.6)65 (19.8)

————

45°

up to 5 kWover 5 up to 10 kW

over 10 up to 20 kWover 20 up to 50 kW

9 (2.7)11 (3.4)15 (4.5)18 (5.5)

24 (7.3)36 (11.0)46 (14.0)78 (23.8)

————

Page 38: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

37

240 Series Unit Heater

Heater Listing

KW Volts Ph TotalAmps*

Approx. AirTemperatureRise °F (°C)

2-StageControl

Std.ControlVoltage

Unit Size

CatalogNumber (2)

2.5208 1 12.30

23 (-5)1B 208 1 HX-240-U1025C

240 1 10.7 1B 240 1 HX-240-U1025J277 1 9.40 1B 277 1 HX-240-U1025N

3.3208 1 16.17

30 (-1.1)1B 208 1 HX-240-U1033C

240 1 14.05 1B 240 1 HX-240-U1033J277 1 12.21 1B 277 1 HX-240-U1033N

3.7 480 3 4.66 34 (1.1) 1A 24 1 HX-240-U1037U

3.8208 3 10.85

35 (1.6)1A 24 1 HX-240-U1038D

240 3 9.44 1A 24 1 HX-240-U1038K

5

208 1 24.34

46 (7.77)

1B 208 1 HX-240-U1050C240 1 21.13 1B 240 1 HX-240-U1050J277 1 18.35 1B 277 1 HX-240-U1050N208 3 14.18 1A 24 1 HX-240-U1050D240 3 12.33 1A 24 1 HX-240-U1050K480 3 6.22 1A 24 1 HX-240-U1050U

6.7208 1 32.91

33 (0.5)1B 24 2 HX-240-U2067C

240 1 28.62 1B 24 2 HX-240-U2067J277 1 24.79 1B 24 2 HX-240-U2067N

7.5

208 1 36.80

37 (2.7)

1B 24 2 HX-240-U2075C240 1 32.00 1B 24 2 HX-240-U2075J208 3 21.52 1A 24 2 HX-240-U2075D240 3 18.74 1A 24 2 HX-240-U2075K480 3 9.39 1A 24 2 HX-240-U2075U

9.9 208 1 48.30 49 (9.4) 1B 24 2 HX-240-U2099C

10

240 1 42.37

49 (4.9)

1B 24 2 HX-240-U2100J277 1 36.70 1B 24 2 HX-240-U2100N208 3 28.46 1A 24 2 HX-240-U2100D240 3 24.76 1A 24 2 HX-240-U2100K480 3 12.40 1A 24 2 HX-240-U2100U

13.2 277 1 48.35 28 (-2.2) 1B 24 3 HX-240-U3132N

13.3208 1 64.79

28 (-2.2)Standard 24 3 HX-240-U3133C-X (1)

240 1 56.27 Standard 24 3 HX-240-U3133J-X

15208 3 42.48

32 (0)1B 24 3 HX-240-U3150D

240 3 36.93 1B 24 3 HX-240-U3150K480 3 18.44 1B 24 3 HX-240-U3150U

19.9208 1 96.52

43 (6.11)Standard 24 3 HX-240-U3199C-X (1)

240 3 48.72 1B 24 3 HX-240-U3199K

20

240 1 84.18

43 (6.11)

Standard 24 3 HX-240-U3200J-X (1)277 1 72.90 Standard 24 3 HX-240-U3200N-X (1)208 3 56.36 Standard 24 3 HX-240-U3200D-X480 3 24.46 1B 24 3 HX-240-U3200U

25208 3 70.90

26 (-3.3)Standard 24 4 HX-240-U4250D-X

240 3 61.64 Standard 24 4 HX-240-U4250K-X480 3 30.77 1B 24 4 HX-240-U4250U

33.3208 3 93.93

35 (1.6)Standard 24 4 HX-240-U4333D-X

240 3 81.61 Standard 24 4 HX-240-U4333K-X480 3 40.75 1B 24 4 HX-240-U4333U

37.5208 3 105.59

39 (3.8)Standard 24 4 HX-240-U4375D-X

240 3 91.71 Standard 24 4 HX-240-U4375K-X480 3 45.80 1A 24 4 HX-240-U4375U

49.8 208 3 139.73 52 (11.1) Standard 24 4 HX-240-U4498D-X

50240 3 121.8

52 (11.1)Standard 24 4 HX-240-U4500K-X

480 3 60.84 Standard 24 4 HX-240-U4500U-X*Total Amps = Heating element amps and motor amps.(1) Disconnect switch unavailable.(2) All Standard heaters are supplied with 24V transformer and contactor except up to 5 KW single-phase units. Optional low voltage transformer and contactor are avail-

able for these heaters, see Factory Built-in Option ‘R1’.

2-stage heaters can be field wired as single stage.1A = Optional 2-stage control, unbalanced (option X)1B = Optional 2-stage control, balanced (option X).

Page 39: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

38

AIRFLOW

DEPTH

8' (2.4M)MINIMUMTO FLOOR

W6

(152 mm)MIN

6(152 mm)

MIN

D (MIN)

H

240 Series Unit Heater

KWWIn.

(mm)

HIn.

(mm)

DepthIn.

(mm)

AIn.

(mm)

BIn.

(mm)

CIn.

(mm)

DIn.

(mm)

EIn.

(mm)

FIn.

(mm)

GIn.

(mm)

HIn.

(mm)

IIn.

(mm)

JIn.

(mm)

up to 5 12.875(327)

17.750(450)

7.625(194)

8(203)

10.188(284)

18(457)

10(254)

8(203)

16(406)

5(127)

6.44(164)

6.44(164)

5(127)

5.1 to 10 16.875(429)

24.250(616)

7.625(194)

6(152)

10.188(237)

18(457)

10(254)

8 (203)

16(406)

5(127)

6.44(164)

6.44(164)

5(127)

10.1 to 20 16.875(429)

24.250(616)

11.375(289)

6(152)

8.313(237)

18(457)

12(305)

12(305)

32(813)

5(127)

10.13(257)

5(127)

10.13(257)

20.1 to 50 26.937(684)

35.500(902)

15.625(397)

6.281(236)

11.937(380)

13(330)

12 (305)

16(406)

32(813)

7(178)

12.92(328)

7(178)

12.92(328)

Heater Dimensions

W A

H

B

8' (2.4M)MINIMUMTO FLOOR

12" (305mm)MINIMUM

FIG. 1 HORIZONTAL WALL MOUNTING WITH MOUNTING ARM FIG. 2 HORIZONTAL CEILING MOUNT WITH MTG ARM

FIG. 3 HORIZONTAL CEILING MOUNT WITH THREADED ROD

CEILING CEILING

CEILING CEILING

C

H

W6

(152 mm)MIN

6"(152 mm)

MIN

8' (2.4M)MINIMUMTO FLOOR

DEPTH

EMIN

ACCESSDOOR

CLEARANCE

FINLETGRILLE

CLEARANCETO ANYWALL

(3 SIDES)

C

w

8' (2.4M)MINIMUMTO FLOOR

FIG. 4 VERTICAL CEILING MOUNT WITH MTG ARM

WAL

L WALL

WALL

WALL

WALLW

ALL

WAL

L

WAL

L

Wall/CeilingMtg Bracket

Wall/CeilingMtg Bracket

Wall/CeilingMtg Bracket

Page 40: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

39

240 Series Unit Heater

Airflows, Weights and Air Throw

UnitSize CFM

InstalledWeightlb (kg)

Max. AirThrowft. (m)

1 350 25 (11.3) 15 (4.6)2 650 40 (18.1) 18 (5.5)3 1500 55 (25) 41 (12.5)4 3100 155 (70.3) 62 (18.9)

Finish/Color OptionsCode Finish ColorNone

PolyesterPowder Coat

CamelA0 GreyA1 YellowA2 RedA3 WhiteA4 BlueA5 Steel (unpainted) GalvanizedA7 Polyester Powder Coat Beige

Catalog Number Description

1024149 Universal wall & ceiling mounting bracket up to 10 KW

1024150 Universal wall & ceiling mounting bracket over 10 KW up to 20 KW

1024151 Universal wall & ceiling mounting bracket over 20 KW

Mounting Brackets

Remote Thermostat Selection Chart

KW Catalog Number Volts Ph

1-Stage Line

Voltage

1-StageLow

Voltage (b)

2-StageLow

Voltage (b)

2.5HX-240-U1025C 208 1 1007014 1006998 (a) 1007030 (a)HX-240-U1025J 240 1 1007014 1006998 (a) 1007030 (a)HX-240-U1025U 277 1 1007014 1006998 (a) 1007030 (a)

3.3HX-240-U1033C 208 1 1007014 1006998 (a) 1007030 (a)HX-240-U1033J 240 1 1007014 1006998 (a) 1007030 (a)HX-240-U1033N 277 1 1007014 1006998 (a) 1007030 (a)

3.7 HX-240-U1037U 480 3 NA 1006998 1007030

3.8HX-240-U1038D 208 3 NA 1006998 1007030HX-240-U1038K 240 3 NA 1006998 1007030

5HX-240-U1050C 208 1 NA 1006998 (a) 1007030 (a)HX-240-U1050J 240 1 1007014 1006998 (a) 1007030 (a)HX-240-U1050N 277 1 1007014 1006998 (a) 1007030 (a)All Other UHIR Heaters NA 1006998 1007030

(a) Add option ‘R1’ for 24V control on these units.(b) Option ‘R2’ is unavailable with any Heatrex supplied remote low voltage thermostats.

1007030

1007014

1006998

CEILING

WALL

WAL

L

EMIN

ACCESSDOOR

CLEARANCE

8' (2.4M)MINIMUMT0 FLOOR

6"(152mm)

MIN.

FINLET GRILLECLEARANCE

TO ANYWALL

(3 SIDES)

AIRFLOW

G

H

J

RESET

I

FIG. 6 VERTICAL CEILING MOUNT WITH THREADED ROD

FIG. 5 THREADED ROD (3/8 - 16) ATTACHMENT POINT DIMENSIONS

GI

J

H

Page 41: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

40

926 Series Unit Heater

The 926 Series unit heater is designed for industrial and commercial applications.

• Large Capacity: Heavy-duty construction with ratings up to 60 KW at 2,000 CFM.

• Control Options: Wide range of factory built-in or field- installed control options to meet job specifications.

• Single Point Electrical Hook-up: Heater, fan motor and controls are all connected to the same branch circuit. Field connections and built-in controls are easily accessed in the side-mounted control compartment.

• Discharge Direction: The UCI heater may be mounted hor-izontally using one of two brackets (supplied) or vertically using four threaded rods (not included).

Applications

• Garages

• Mechanical Rooms

• Stairwells

• Vestibules

• Warehouses

• Workshops

Standard Construction FeaturesHeating Elements – Industrial grade stainless steel tubular elements in 2-10 KW units and steel finned tubular elements in 15-60 KW units.

Housing – Cabinet is constructed of 18 and 20-gauge galva-nized steel finished with durable almond polyester powder paint.

Outlet Grille – The outlet grille has individually adjustable louvers to direct airflow. A protective outlet mesh screen, provided on 2-30 KW heaters, allows for lower mounting heights.

Fan Motor – Totally enclosed, thermally protected motor with factory-lubricated ball bearings (except for 15 to 25 kW at 208/240V) operates at 58 dBA (2-10 kW), 67 dBA (15-30 kW) or 77 dBA (40-60 kW). Blow-through design reduces motor operating temperature for longer life.

Built-in Controls – Include 240/208 volt control circuit (with transformer if necessary), automatic reset thermal cutout, fan override and factory-installed contactor. Power fusing is sup-plied for heaters over 48 amps.

Mounting Bracket – Wall and ceiling bracket provided with each unit under 40 KW for horizontal mounting. 40-60 KW heaters furnished with four corner support brackets for ceil-ing mounting.

Installation Requirements – For best performance, do not install unit heaters above recommended maximum mounting heights of 2-10 KW, 8-feet; 15-30 KW, 10-feet; 40-60 KW, 15-feet. All but 40-60 KW heaters can be installed at lower mounting heights. Minimum height for 40-60 KW heaters is 8-feet. Maximum ambient room temperature for proper operation is 85°F. These units are not for residential use in the United States.

Page 42: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

41

926 Series Unit Heater

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

(1) Add option “R2” when a low voltage remote thermostat is required.(2) Not available with heater part number 926U10000CA.

Code DescriptionC Three Pole Contactor

D1 Disconnect Switch 32 Amp (2)D2 Disconnect Switch 64 Amp (2)D5 Disconnect Switch 80 Amp (2)G Fusing

M Manual ResetR1 24V RelayR2 24V Relay with Transformer (1)T Thermostat (2)U Fan “ON” SwitchX 120V Control, fused secondary and grounded

CatalogNumber Description

926-124513 Diffuser cone (2-10 kW)926-124514 Diffuser cone (15-30 kW)926-161077 Diffuser cone (40-60 kW)926-124515 Thermostat Kit926-124516 24V Relay Kit926-124518 24V Relay Kit with Transformer926-124517 24V Relay Kit with 208V Transformer926-124520 24V Relay Kit with 480V Transformer

CatalogNumber

SwitchType Color Type Tamper-

proofThermo-

meterAmps @

120-240VAmps

@ 277VPilotDuty

Posi-tiveOff

Tempera-ture

Range oF

901-124640 Bimetal Beige SPST No No 22 19 — No 40-80

901-124642 Bimetal White SPST No No 22 19 — No 40-80

901-124643 Bimetal White DPST No No 22 19 — Yes 40-80

901-TH114-A-420 Electronic White DPST No Digital 15A @240V — — No 40-86

Low Voltage Thermostats901-1006998 Bimetal White SPST No No — — 30VA at

30V max Yes 50-90

901-219981Precision

SnapAction

White SPST No No — — 36VA at30V max No 45-95

Line Voltage Thermostats

Accessories -

Catalog Number Description

901-124644 Inside dimensions: 6-3/8” (length), 3-1/2” (height), 3” (depth)

901-F29-0198 Inside dimensions: 8-1/4” (length), 5-3/8” (height), 3-1/2” (depth)

901-124640 901-124642901-124643

901-TH114-A-420 901-1006998 901-219981 901-124644 901-F29-0198

Clear universal thermostat guard. Protects both line and low voltage thermostats against vandalism, damage, and unau-thorized adjustment of thermostat settings.

Page 43: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

42

926 Series Unit Heater

Heater Listing

(1) Total Amps = Heating element amps and motor amps.Other voltages available. Consult factory.Only available with almond finish.* Can be converted from 3 to 1-phase in the field.

KW Volts Phase TotalAmps (1) CFM

Approximate AirTemperature Rise

°F (°C)

Motor DataCatalogNumberHP RPM Voltage

2

208 1 10.3 510 13 (7) 1/30 1550 240/208 HX-926U02000CA208 3 6.3 510 13 (7) 1/30 1550 240/208 HX-926U02000DA240 1 9.0 510 13 (7) 1/30 1550 240/208 HX-926U02000JA240 3 5.5 510 13 (7) 1/30 1550 240/208 HX-926U02000KA277 1 7.9 510 13 (7) 1/30 1550 240/208 HX-926U02000NA480 1 4.9 510 13 (7) 1/30 1550 240/208 HX-926U02000TA480 3 3.1 510 13 (7) 1/30 1550 240/208 HX-926U02000UA

3

208 1 15.1 510 18 (10) 1/30 1550 240/208 HX-926U03000CA208 3 9.0 510 18 (10) 1/30 1550 240/208 HX-926U03000DA240 1 13.2 510 18 (10) 1/30 1550 240/208 HX-926U03000JA240 3 7.9 510 18 (10) 1/30 1550 240/208 HX-926U03000KA277 1 11.5 510 18 (10) 1/30 1550 240/208 HX-926U03000NA480 1 7.0 510 18 (10) 1/30 1550 240/208 HX-926U03000TA480 3 4.3 510 18 (10) 1/30 1550 240/208 HX-926U04000UA

4

208 1 19.9 510 25 (14) 1/30 1550 240/208 HX-926U04000CA208 3 11.8 510 25 (14) 1/30 1550 240/208 HX-926U04000DA240 1 17.4 510 25 (14) 1/30 1550 240/208 HX-926U04000JA240 3 10.3 510 25 (14) 1/30 1550 240/208 HX-926U04000KA277 1 15.1 510 25 (14) 1/30 1550 240/208 HX-926U04000NA480 1 9.0 510 25 (14) 1/30 1550 240/208 HX-926U04000TA480 3 5.5 510 25 (14) 1/30 1550 240/208 HX-926U04000UA

5

208 1 24.7 700 23 (13) 1/30 1550 240/208 HX-926U05000CA208 3/1* 14.6 700 23 (13) 1/30 1550 240/208 HX-926U05000DA240 1 21.5 700 23 (13) 1/30 1550 240/208 HX-926U05000JA240 3/1* 12.7 700 23 (13) 1/30 1550 240/208 HX-926U05000KA277 1 18.8 700 23 (13) 1/30 1550 240/208 HX-926U05000NA480 1 11.1 700 23 (13) 1/30 1550 240/208 HX-926U05000TA480 3 6.7 700 23 (13) 1/30 1550 240/208 HX-926U05000UA

7.5

208 1 36.8 700 34 (19) 1/30 1550 240/208 HX-926U07500CA208 3/1* 21.5 700 34 (19) 1/30 1550 240/208 HX-926U07500DA240 1 32.0 700 34 (19) 1/30 1550 240/208 HX-926U07500JA240 3/1* 18.7 700 34 (19) 1/30 1550 240/208 HX-926U07500KA277 1 27.8 700 34 (19) 1/30 1550 240/208 HX-926U07500NA480 1 16.3 700 34 (19) 1/30 1550 240/208 HX-926U07500TA480 3 9.7 700 34 (19) 1/30 1550 240/208 HX-926U07500UA

10

208 1 48.8 700 45 (25) 1/30 1550 240/208 HX-926U10000CA208 3 28.5 700 45 (25) 1/30 1550 240/208 HX-926U10000DA240 1 42.4 700 45 (25) 1/30 1550 240/208 HX-926U10000JA240 3/1* 24.8 700 45 (25) 1/30 1550 240/208 HX-926U10000KA480 1 21.5 700 45 (25) 1/30 1550 240/208 HX-926U10000TA480 3 12.7 700 45 (25) 1/30 1550 240/208 HX-926U10000UA

Page 44: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

43

800-243-8162www.Heatrex.com

926 Series Unit Heater

Heater Listing (cont.)

(1) Total Amps = Heating element amps and motor amps.Other voltages available. Consult factory.Only available with almond finish.

KW Volts Phase TotalAmps (1) CFM

Approximate AirTemperature Rise

°F (°C)

Motor DataCatalogNumberHP RPM Voltage

15

208 1 73.2 1300 36 (20) 1/8 1550 240/208 HX-926U15000CA208 3 42.7 1300 36 (20) 1/8 1550 240/208 HX-926U15000DA240 1 63.6 1300 36 (20) 1/8 1550 240/208 HX-926U15000JA240 3 37.2 1300 36 (20) 1/8 1550 240/208 HX-926U15000KA480 1 32.2 1400 34 (19) 1/3 1725 480 (1 ph) HX-926U15000TA480 3 18.9 1400 34 (19) 1/3 1725 480 (1 ph) HX-926U15000UA

20

208 1 97.3 1300 49 (27) 1/8 1550 240/208 HX-926U20000CA208 3 56.6 1300 49 (27) 1/8 1550 240/208 HX-926U20000DA240 1 84.4 1300 49 (27) 1/8 1550 240/208 HX-926U20000JA240 3 49.2 1300 49 (27) 1/8 1550 240/208 HX-926U20000KA480 1 42.6 1400 45 (25) 1/3 1725 480 (1 ph) HX-926U20000TA480 3 25 1400 45 (25) 1/3 1725 480 (1 ph) HX-926U20000UA

25

208 1 121.3 1300 61 (34) 1/8 1550 240/208 HX-926U25000CA208 3 70.5 1300 61 (34) 1/8 1550 240/208 HX-926U25000DA240 1 105.3 1300 61 (34) 1/8 1550 240/208 HX-926U25000JA240 3 61.2 1300 61 (34) 1/8 1550 240/208 HX-926U25000KA480 1 53 1400 56 (31) 1/3 1725 480 (1 ph) HX-926U25000TA480 3 31 1400 56 (31) 1/3 1725 480 (1 ph) HX-926U25000UA

30 480 3 37 1400 68 (38) 1/3 1725 480 (1 ph) HX-926U30000UA40 480 3 49.6 2000 63 (35) 3/4 1140 480 (3 ph) HX-926U40000UA50 480 3 61.6 2000 79 (44) 3/4 1140 480 (3 ph) HX-926U50000UA60 480 3 73.7 2000 95 (53) 3/4 1140 480 (3 ph) HX-926U60000UA

I

B

H

D

E

A

C

G (MIN)

F

4 Threaded Rods 1/2-13 UNC

Wall Bracket

Ceiling Bracket Support Brackets40-60 KW

Dimensions and Weights

KW AIn. (mm)

BIn. (mm)

CIn. (mm)

DIn. (mm)

EIn. (mm)

FIn. (mm)

GIn. (mm)

HIn. (mm)

IIn. (mm)

Weightlb (kg)

2-10 12 (305)

16-1/2 (419)

17 (432)

14-1/16 (357)

11-7/16 (290)

195/16(490)

12(305)

4-7/8 (123)

16-7/8 (428)

45 (20)

15-30 17-1/2 (444)

21-7/8 (556)

22-1/2(572)

18-1/2(470)

16 (407)

24-13/16(630)

12 (305)

5-13/16 (148)

23-5/16 (592)

85 (39)

40-60 23 (585)

25-1/4(641)

34-1/4(870) — — 36-3/8

(924)12

(305)12

(305)35

(890)150 (68)

Page 45: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

44

925 Series Unit Heater

The 925 Series unit heater is an economical choice for commercial heating applications.

• Compact Design: Ideal for primary or spot heating applica-tions. Units can be wall or ceiling-mounted for horizontal airflow.

• Versatility: Three different heater KW ratings can be field converted to either 240 or 208 single-phase power.

• Built-in Adjustable Thermostat: Minimum temperature setting on thermostat can be used to disable the heater.

Applications• Basements

• Entrances• Garages

• Mechanical Rooms

Standard Construction FeaturesHeating Elements – Nickel-chromium wire which provides instant heat with no residual heat. The element is installed on high-strength and specially designed insulation ceramic for quiet and smooth operation. The open-coil element is also humidity proof.

Housing – Cabinets are constructed of 20-gauge galvanized steel with an almond polyester powder paint finish.

Outlet Grille – The outlet grille has adjustable louvers to direct airflow and a protective screen for additional safety.

Fan/Motor – The fan supplies 300 CFM at 51 dBA. The motor is permanently lubricated and totally enclosed.

Built-in Controls – Automatic reset thermal cutout and adjust-able thermostat.

Mounting Bracket – A universal mounting bracket for either wall or ceiling installation allows for 360° rotation of the heater.

Dimensions, Airflows and Weights

(1)Total Amps = Heating element amps and motor amps.Only available with almond finish.

Watts Volts Phase TotalAmps (1) CFM

Approximate AirTemperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

2000/1500 240/208 1 8.7/7.6 300 21/16 (12/9) 20 (9) HX-925U02000VA

3000/2250 240/208 1 12.9/11.2 300 32/24 (18/13) 20 (9) HX-925U03000VA

5000/3750 240/208 1 21.2/18/4 300 53/40 (29/22) 20 (9) HX-925U05000VA

• Storage Rooms

• Workshops

• Service Areas in Air Handling Units

Page 46: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

45

928 SeriesVertical Unit Heater

The 928 Series unit heater is designed to heat buildings with high ceilings. It may also be used to re-circulate warm air that builds up near ceilings. UVI heaters can be used as primary, supplemental or dual heating systems in commercial or industrial buildings.

• Vertical Airflow: Suitable for applications in high bay industri-al buildings where columns, machinery or warehouse stock would obstruct horizontal air movement.

• Air Distribution Patterns: Three optional air diffusers produce different air distribution patterns to accommodate various applications.

Applications• Aircraft Hangars

• Factories

• Garages

• Gyms

• High Bay Areas

• Malls

• Power Generating Stations

• Shipping and Receiving Areas

• Warehouses

Standard Construction FeaturesHeating Elements – Steel finned tubular elements are grounded for extra safety.

Housing – Cabinet is constructed of 18-gauge galvanized steel with an almond polyester powder paint finish.

Fan Motor – Quiet, totally enclosed motor is thermally pro-tected.

Built-in Controls – Contactor, fan override, terminal block for remote fan control and linear automatic reset thermal cut-out.

Installation Requirements – Do not install heater closer than 24 inches from walls and ceiling. Mount heaters out of reach, at least eight feet from the floor.

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

Code Description

D1 Disconnect Switch 40A, 600V, 3-Pole

D2 Disconnect Switch 80A, 600V, 3-Pole

R1 24V Relay

R2 24V Relay with Transformer

X 120V Control, fused secondary and grounded

CatalogNumber Description

928-124521* Single Cone Diffuser 5-10 KW

928-124522 Single Cone Diffuser 15-30 KW

928-124523* Triple Cone Diffuser 5-10 KW

928-124524 Triple Cone Diffuser 15-30 KW

928-124525* Jet Cone Diffuser 5-10 KW

928-124526 Jet Cone Diffuser 15-30 KW

928-124527 24V Relay Kit

928-124528 24V Relay Kit with Transformer-208V

928-124529 24V Relay Kit with Transformer-240V* For heater part number 928C09600UA, all diffusers must be ordered in the 15-30 kW size.

Page 47: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

46

Without Cone Triple Cone

H

S

Jet Cone

H

S

H

S

Single Cone

H

S

Maximum Mounting Height

Air Distribution Patterns

H H H H

SSSS

KWWithout Cone Single Cone Triple Cone Jet Cone

HFt (m)

SFt (m)

HFt (m)

SFt (m)

HFt (m)

SFt (m)

HFt (m)

SFt (m)

5-10 12 (4) 19 (6) 8 (3) 22 (7) 10 (3) 31 (10) 16 (5) 20 (6)15-30 18 (6) 20 (9) 10 (4) 33 (10) 14 (4) 43 (13) 22 (7) 26 (9)

Model(Without Cone)

A B C

In. (mm) In. (mm) In. (mm)

5-10 KW 23-1/8 (587) 8 (203)

6-15/16 (176)

15-30 KW 30-1/4 (768) 12-3/16 (310)

6-11/16 (170)

Support Brackets

24"

B

24"A

C

CatalogNumber

SwitchType Color Type Tamper-

proofThermo-

meterAmps @

120-240VAmps

@ 277VPilotDuty

Posi-tiveOff

Tempera-ture

Range oF

901-124640 Bimetal Beige SPST No No 22 19 — No 40-80

901-124642 Bimetal White SPST No No 22 19 — No 40-80

901-124643 Bimetal White DPST No No 22 19 — Yes 40-80

901-TH114-A-420 Electronic White DPST No Digital 15A @240V — — No 40-86

Low Voltage Thermostats901-1006998 Bimetal White SPST No No — — 30VA at

30V max Yes 50-90

901-219981Precision

SnapAction

White SPST No No — — 36VA at30V max No 45-95

Line Voltage Thermostats

928 SeriesVertical Unit Heater

Page 48: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

47

928 SeriesVertical Unit Heater

Heater Listing

(1) Total Amps = Heating element amps and motor amps.Only available with almond finish.

KW Volts Phase TotalAmps (1) CFM

Approx. AirTemp. Rise

°F (C°)

Motor DataWeightIb (kg)

CatalogNumberHP RPM Voltage

3.2 480 3 4.7 450 22 (12) 1/25 1050 208/240 75 (34) HX-928C03200UA4.8 480 3 6.6 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C04800UA

5

208 1 24.9 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000CA208 3 14.7 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000DA240 1 21.7 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000JA240 3 12.9 450 34 (19) 1/25 1050 208/240 75 (34) HX-928C05000KA

6.4 480 3 8.6 600 34 (19) 1/25 1050 208/240 75 (34) HX-928C06400UA

7.5208 3 21.7 600 40 (22) 1/25 1050 208/240 75 (34) HX-928C07500DA240 1 32.1 600 40 (22) 1/25 1050 208/240 75 (34) HX-928C07500JA240 3 18.9 600 40 (22) 1/25 1050 208/240 75 (34) HX-928C07500KA

9.6 480 3 12.5 1200 25 (14) 1/6 1140 208/240 100 (48) HX-928C09600UA

10208 3 28.6 750 41 (23) 1/25 1050 208/240 75 (34) HX-928C10000DA240 1 42.5 750 41 (23) 1/25 1050 208/240 75 (34) HX-928C10000JA240 3 24.9 750 41 (23) 1/25 1050 208/240 75 (34) HX-928C10000KA

12.8 480 3 16.3 1200 34 (19) 1/6 1140 208/240 100 (48) HX-928C12800UA

15208 3 42.6 1200 40 (22) 1/6 1140 208/240 100 (48) HX-928C15000DA240 1 63.4 1200 40 (22) 1/6 1140 208/240 100 (48) HX-928C15000JA240 3 37 1200 40 (22) 1/6 1140 208/240 100 (48) HX-928C15000KA

16 480 3 20.2 1600 32 (18) 1/6 1140 208/240 100 (48) HX-928C16000UA19.2 480 3 24 1600 38 (21) 1/6 1140 208/240 100 (48) HX-928C19200UA

20208 3 56.5 1600 40 (22) 1/6 1140 208/240 100 (48) HX-928C20000DA240 1 84.2 1600 40 (22) 1/6 1140 208/240 100 (48) HX-928C20000JA240 3 49.1 1600 40 (22) 1/6 1140 208/240 100 (48) HX-928C20000KA

25208 3 70.4 2000 40 (22) 1/6 1140 208/240 100 (48) HX-928C25000DA240 1 105.0 2000 40 (22) 1/6 1140 208/240 100 (48) HX-928C25000JA240 3 61.1 2000 40 (22) 1/6 1140 208/240 100 (48) HX-928C25000KA

30208 3 84.2 2300 41 (23) 1/6 1140 208/240 100 (48) HX-928C30000DA240 1 125.9 2300 41 (23) 1/6 1140 208/240 100 (48) HX-928C30000JA240 3 73.2 2300 41 (23) 1/6 1140 208/240 100 (48) HX-928C30000KA

Accessories - Catalog Number Description

901-124644 Inside dimensions: 6-3/8” (length), 3-1/2” (height), 3” (depth)

901-F29-0198 Inside dimensions: 8-1/4” (length), 5-3/8” (height), 3-1/2” (depth)

901-124640 901-124642901-124643

901-TH114-A-420 901-1006998 901-219981 901-124644 901-F29-0198

Clear universal thermostat guard. Protects both line and low voltage thermostats against vandalism, damage, and unau-thorized adjustment of thermostat settings.

Page 49: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

48

Comparison ChartWall, Ceiling and Floor Heaters

FeaturesArchitectural

Wall933

CommercialWall932

EuropeanWall935

HybridConvection

940

Wall934

Register Wall930

Typical Applications

EntrywaysOffices

Receptionareas

Guard housesOffices

Stairwells

OfficesRestrooms

OfficesRestrooms

Condominiums

Small officesStorage rooms

HallwaysStairwells

Wattage Range up to 12,000

up to 12,000

up to 1,500

up to2,000 up to 2,000 up to 2,000

Voltages up to 480/3

up to 480/3

up to240/1

up to240/1

up to 240/1

up to 240/1

Airflow CFM up to 480 up to 480 up to 70 Convection up to 80 up to 80

Element TypeSteel

finned tubular

Steelfinnedtubular

StitchedRibbon

Element

FastResponse

CoilElement

Steelfinnedtubular

Steelfinnedtubular

StandardConstruction

1/8” thickextruded

aluminum grille

18-gauge steel grille

20-gauge steel grille

CastAluminum

grille

22-gauge steel grille

20-gauge steel grille

Finish Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Mounting Surface orrecessed

Surface orrecessed

Surface orrecessed

Surface orrecessed

Surface orrecessed

Surface orrecessed

Custom Colors Yes Yes Yes Yes Yes Yes

Agency Approvals CSAus CSAus CSAus CSAus CSAus CSAus

933

932

935

934

930

940

Page 50: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

49

Comparison ChartWall, Ceiling and Floor Heaters

Cabinet922

Fan-Forced Ceiling

936

Fan Forced Ceiling

937

CommercialCeiling

931

CommercialCeiling

941

Toe-Space938

Floor Insert939

ClassroomsHallways

Meeting rooms

ClassroomsDay care

Reception areas

ClassroomsDay care

Reception areas

EntrywaysHallways

Restrooms

EntrywaysHallways

Restrooms

KitchensReception areas

Under sliding doorsUnder windows

up to 24,000

up to 10,000

up to 5,000

up to8,000 up to 2,000 up to

1,000up to 1,500

up to 480/3 up to 480/3 up to 480/3 up to 480/1 up to

240/1 up to 240/1 up to 240/1

up to 1,000 up to 600 up to 310 up to 320 up to 80 80 80

Steelfinnedtubular

Stainless steel finned tubular aluminum fins

Stainless steel finned tubular aluminum fins

Steelfinnedtubular

Steelfinnedtubuler

Steelfinned tubular

Steelfinned tubular

18-gauge steeland extruded

aluminum grille

20-gauge steel grille

with flat ribbon wire outlet grille

20-gauge steel grille

with flat ribbon wire outlet grille

18-gauge steel grille

22-gaugesteel grille

20-gauge steel grille

20-gauge steel body and 14-gauge

grille

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Epoxy/Polyester powder paint

Surface, recessedor ceiling Surface or T-bar Recessed or T-bar Surface, recessed

or T-barSurface or recessed

Recessed under cabinet Recessed in floor

Yes Yes Yes Yes Yes Yes Yes

CSAus CSAus CSAus CSAus CSAus CSAus CSAus

938

939

931

922

941

936

937

Page 51: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

50

Standard Colors

933 SeriesArchitectural Wall Heater

The 933 Series fan-forced wall heater is designed for com-mercial and industrial areas requiring higher KW ratings and quick recovery. The unit provides a burst of heat in areas affected by cold drafts or wide temperature swings. • Efficient Operation: The fan draws air into the top of the

grille and discharges warm air downward to distribute heat and keep floors warm and dry. High CFMs create air circulation within the room to provide uniform tempera-tures.

• Extended Capacity: The 933 Series is available with one, two or three modules and ratings up to 12,000 W and 480 CFM.

Applications• Entryways

• Garages

• Guard Houses

• Offices

• Reception Areas

• Restrooms

• Stairwells

• Vestibules

Standard Construction FeaturesHeating Elements – Steel finned tubular elements.

Outlet Grille – The 933 Series has an architectural extruded aluminum grille in a choice of seven epoxy/polyester powder paint finishes. The closely spaced, heavy bar grille design prevents insertion of foreign objects. The tamperproof ther-mostat adjustment is concealed behind the front cover.

Built-in Controls – Automatic reset thermal cutout, over-temperature warning light, fan override and tamperproof thermostat.

Fan Motor – Permanently lubricated, totally enclosed motor. The single unit has a 160 CFM fan (55 dBA), double unit has 2 x 160 CFM fans (58 dBA), and triple unit has 3 x 160 CFM fans (61 dBA).

Installation Requirements – Heater must be installed at least ten inches from the floor and adjacent walls.

Rough in Dimensions –

Single Unit: 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8” high x 4-1/2” deep.

Double Unit: 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8” high x 4-1/2” deep.

Triple Unit: 12000/9000 Watt heaters: 46-5/8” wide x 19-7/8” high x 4-1/2” deep.

Page 52: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

51

933 SeriesArchitectural Wall Heater

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

Add color code to end of catalog number.Remote Room Thermostat – See pages 111-112.

(1) A built-in thermostat will not be supplied when option R1 or R2 are selected. If built-in thermostat is required with these options, add Code T1 to the part number.

Code Description

D1 Disconnect Switch 600V, Three-pole, 32 Amp

D2 Disconnect Switch 600V, Three-pole, 64 Amp

D3 Disconnect Switch 277V, Double-pole, 16 Amp

R1 24V Relay (1)

R2 24V Relay with Transformer (1)

S3 Fan On/Auto Switch

CatalogNumber Description

933-124501 Surface Mounting Box (1500-4800 W)

933-158471 Surface Mounting Box (6000-8000 W)

933-269345 Surface Mounting Box (12000 W)

933-151114 1” Semi Recessed Trim Kit (1500-4800 W)

933-166530 1” Semi Recessed Trim Kit (6000-8000 W)

933-269346 1” Semi Recessed Trim Kit (12000W)

933-151115 2” Semi Recessed Trim Kit (1500-4800 W)

933-166531 2” Semi Recessed Trim Kit (6000-8000 W)

933-269347 2” Semi Recessed Trim Kit (12000W)

KOE Ø22 mmKOE Ø7/8"

KOE Ø22 mmKOE Ø7/8"

408 mm16 1/16"

810 mm31 7/8"

767 mm30 3/16"

1227 mm48 5/16"

1185 mm46 5/8"

578 mm22 3/4"

40 mm1 9/16"

368 mm14 7/16"

51 mm2"

212 mm8 5/16"

74 mm2 7/8" 55 mm

2 3/16"

34 mm1 5/16"

506 mm19 7/8"

34 mm1 5/16"

51 mm2"

51 mm2"

Installation (All Models)Side View (All Models)

Surface

Recessed

Front ViewFront View Front ViewSide View

Top View Top ViewTop View

Required WallDepth Opening

Single Unit Double Unit Triple Unit

109 mm4 5/16"

107 mm4 3/16"

584 mm23"

Color Code ChartCode Color Code Color

BZ Bronze W White

AE Metallic Silver A Almond

CM Metallic Charcoal AL Aluminum

BK Semi-gloss black

1500/1125-4800Watt Heaters

6000/4500-8000Watt Heaters

12000/9000Watt Heaters

Page 53: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

52

933 SeriesArchitectural Wall Heater

Heater ListingBuilt-in tamperproof thermostat is included.

(1) Total Amps = Heating element amps and motor amps.Add color code to end of catalog number.Standard colors. See page 7 for color codes to be added to the end of catalog number.

Watts Volts Phase TotalAmps (1) CFM

Approximate Air Temperature Rise

oF (oC)

Weightlb (kg)

Catalog Number

1500/1125 240/208 1 6.6/5.8 160 30/27 (17/12) 24 (11) HX-933U01500V

1500 120 1 12.9 160 30 (17) 24 (11) HX-933U01500B

1500277 1 5.8 160 30 (17) 24 (11) HX-933U01500N

480 1 3.5 160 30 (17) 28 (13) HX-933U01500T

2000/1500 240/208 1 8.7/7.6 160 40/30 (22/17) 24 (11) HX-933U02000V

2000

208 1 10.0 160 40 (22) 24 (11) HX-933U02000C

277 1 7.6 160 40 (22) 24 (11) HX-933U02000N

480 1 4.5 160 40 (22) 28 (13) HX-933U02000T

3000/2250 240/208 1 12.9/11.2 160 60/45 (33/25) 24 (11) HX-933U03000V

3000277 1 11.2 160 60 (33) 24 (11) HX-933U03000N

480 1 6.6 160 60 (33) 28 (13) HX-933U03000T

4000/3000 240/208 1 17.0/14.8 160 80/60 (44/33) 24 (11) HX-933U04000V

4000

208 1 19.6 160 80 (44) 24 (11) HX-933U04000C

277 1 14.8 160 80 (44) 24 (11) HX-933U04000N

480 1 8.7 160 80 (44) 28 (13) HX-933U04000T

4800/3600 240/208 1 20.4/17.7 160 96/72 (53/40) 24 (11) HX-933U04800V

4800

208 1 23.5 160 96 (53) 24 (11) HX-933U04800C

277 1 17.7 160 96 (53) 28 (13) HX-933U04800N

480 1 10.4 160 96 (53) 28 (13) HX-933U04800T

6000/4500 240/208 1 25.4/22.0 320 60/45 (33/25) 50 (23) HX-933U06000V

6000277 1 22.1 320 60 (33) 50 (23) HX-933U06000N

480 1 12.9 320 60 (33) 50 (23) HX-933U06000T

8000/6000 240/208 1 33.7/29.2 320 80/60 (44/33) 50 (23) HX-933U08000V

8000

208 1 38.9 320 80 (44) 50 (23) HX-933U08000C

277 1 29.3 320 80 (44) 50 (23) HX-933U08000N

480 1 17.1 320 80 (44) 50 (23) HX-933U08000T12000/9000 240/208 3 29.3/25.4 480 80 (44) 90 (41) HX-933U12000P

12000

208 3 33.7 480 80 (44) 90 (41) HX-933U12000D240 3 29.3 480 80 (44) 90 (41) HX-933U12000K277 1 43.7 480 80 (44) 90 (41) HX-933U12000N480 1 25.4 480 80 (44) 90 (41) HX-933U12000T480 3 14.8 480 80 (44) 90 (41) HX-933U12000U

Page 54: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

53

Standard Special Colors

932 SeriesCommercial Wall Heater

The 932 Series fan-forced wall heater is designed for commer-cial and industrial areas requiring higher KW ratings and quick recovery. The unit provides a burst of heat in areas affected by cold drafts or wide temperature swings. • Efficient Operation: The fan draws air into the top of the

grille and discharges warm air downward to distribute heat and keep floors warm and dry. High CFM’s create air circula-tion within the room to provide uniform temperatures.

• Extended Capacity: The WCI is available with one, two or three modules and ratings up to 12,000 W at 480 CFM.

Applications• Entryways

• Garages

• Guard Houses

• Offices

• Reception Areas

• Restrooms

• Stairwells

• Vestibules

Standard Construction FeaturesHeating Elements – Steel finned tubular elements.

Outlet Grille – The 932 Series has an 18-gauge steel grille with rounded corners and a polyester powder paint finish in white or almond. The external thermostat adjustment knob can be replaced with the concealing plug provided for tamperproof construction.

Built-in Controls – Automatic reset thermal cutout, over-temperature warning light, fan override and thermostat.

Fan Motor – Permanently lubricated, totally enclosed motor. The single unit has a 160 CFM fan (55 dBA), double unit has 2 x 160 CFM fans (58 dBA), and triple unit has 3 x 160 CFM fans (61 dBA).

Installation Requirements – Heater must be installed at least ten inches from the floor and adjacent walls.

Rough in Dimensions –

Single Unit: 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8” high x 4-1/2” deep.

Double Unit: 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8” high x 4-1/2” deep.

Triple Unit: 12000/9000 Watt heaters: 46-5/8” wide x 19-7/8” high x 4-1/2” deep.

Page 55: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

54

932 SeriesCommercial Wall Heater

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

Standard colors - Add W for white finish or A for almond finish to the end of cat-alog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Remote Room Thermostat – See pages 111-112..

Grille Dimensions

1500/1125-4800Watt Heaters

6000/4500-8000Watt Heaters

12000/9000Watt Heaters

(1) A built-in thermostat will not be supplied when option R1 or R2 are selected. If built-in thermostat is required with these options, add Code T1 for tam-per-proof or T5 for adjustable thermostat..

Code Description

D1 Disconnect Switch 600V, Three-pole, 32 Amp

D2 Disconnect Switch, 600V, Three-pole, 64 Amp

D3 Disconnect Switch 277V, Double-pole, 16 Amp

R1 24V Relay (1)

R2 24V Relay with Transformer (1)

S3 Fan On/Auto Switch

CatalogNumber Description

932-124500 Surface Mounting Box (1500-4800 W)

932-158211 Surface Mounting Box (6000-8000 W)

932-158212 Surface Mounting Box (12000 W)

932-146878 1” Semi Recessed Trim Kit (1500-4800 W)

932-166532 1” Semi Recessed Trim Kit (6000-8000 W)

932-166534 1” Semi Recessed Trim Kit (12000 W)

932-153670 2” Semi Recessed Trim Kit (1500-4800 W)

932-166533 2” Semi Recessed Trim Kit (6000-8000 W)

932-166535 2” Semi Recessed Trim Kit (12000 W)

KOE Ø22 mmKOE Ø7/8"

KOE Ø22 mmKOE Ø7/8"

368 mm14 7/16" 51 mm

2"212 mm8 5/16"

74 mm2 7/8" 55 mm

2 3/16"

34 mm1 5/16"

506 mm19 7/8"

34 mm1 5/16"

51 mm2"

51 mm2"

Installation (All Models)Side View (All Models)

Surface

Recessed

Front View Front View Front ViewSide View

Top View Top ViewTop View

Required WallDepth Opening

Single Unit

104 mm4 1/8"

410 mm16 1/8"

810 mm31 7/8"

767 mm30 3/16"

1227 mm48 5/16"

1185 mm46 5/8"

561 mm22 1/16"

33 mm1 5/16"

104 mm4 1/8"

561 mm22 1/16"

Double Unit Triple Unit

Page 56: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

55

932 SeriesCommercial Wall Heater

Heater ListingAdjustable thermostat is included. A hole plug is provided for tamperproof installations.

(1) Total Amps = Heating element amps and motor amps.(2) Single-phase is available upon request, consult factoryStandard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Watts Volts Phase TotalAmps (1) CFM

Approximate Air Temperature Rise

oF (oC)

Weight lbs (kg)

CatalogNumber

1500/1125 240/208 1 6.6/5.8 160 30/22 (17/12) 24 (11) HX-932U01500V

1500

120 1 12.9 160 30 (17) 24 (11) HX-932U01500B

277 1 5.8 160 30 (17) 28 (13) HX-932U01500N

480 1 3.5 160 30 (17) 28 (13) HX-932U01500T

2000/1500 240/208 1 8.7/7.6 160 40/30 (22/17) 24 (11) HX-932U02000V

2000

208 1 10.0 160 40 (22) 24 (11) HX-932U02000C

277 1 7.6 160 40 (22) 28 (13) HX-932U02000N

480 1 4.6 160 40 (22) 28 (13) HX-932U02000T

3000/2250 240/208 1 12.9/11.2 160 60/45 (33/25) 24 (11) HX-932U03000V

3000277 1 11.2 160 60 (33) 28 (13) HX-932U03000N

480 1 6.7 160 60 (33) 28 (13) HX-932U03000T

4000/3000 240/208 1 17.0/14.8 160 80/60 (44/33) 24 (11) HX-932U04000V

4000

208 1 19.6 160 80 (44) 24 (11) HX-932U04000C

277 1 14.8 160 80 (44) 28 (13) HX-932U04000N

480 1 8.7 160 80 (44) 28 (13) HX-932U04000T

4800/3600 240/208 1 20.4/17.7 160 96/72 (53/40) 24 (11) HX-932U04800V

4800

208 1 23.5 160 96 (53) 28 (13) HX-932U04800C

277 1 17.7 160 96 (53) 28 (13) HX-932U04800N

480 1 10.4 160 96 (53) 28 (13) HX-932U04800T

6000/4500 240/208 1 25.4/22.0 320 60/45 (33/25) 50 (23) HX-932U06000V

6000277 1 22.1 320 60 (33) 50 (23) HX-932U06000N

480 1 12.9 320 60 (33) 50 (23) HX-932U06000T

8000/6000 240/208 1 33.7/29.2 320 80/60 (44/33) 50 (23) HX-932U08000V

8000

208 1 38.9 320 80 (44) 50 (23) HX-932U08000C

277 1 29.3 320 80 (44) 50 (23) HX-932U08000N

480 1 17.1 320 80 (44) 50 (23) HX-932U08000T

12000/9000 240/208 3(2) 29.3/25.4 480 80 (44) 90 (41) HX-932U12000P

12000

208 3 33.7 480 80 (44) 90 (41) HX-932U12000D

240 3 29.3 480 80 (44) 90 (41) HX-932U12000K

277 1 43.7 480 80 (44) 90 (41) HX-932U12000N

480 1 25.4 480 80 (44) 90 (41) HX-932U12000T

480 3 14.8 480 80 (44) 90 (41) HX-932U12000U

Page 57: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

56

935 SeriesEuropean Style Wall Heater

The 935 Series wall heater has a stylish, contemporary design with rounded corners and soft lines for an elegant appearance. This heater is ideal for areas with space restrictions and high heating requirements. • Unique Element Design: Stitched ribbon-type heating element pro-

vides instant heat for areas that need to be warmed quickly.• Three Models: The standard single-stage heater is controlled by an

optional remote line-voltage thermostat. Heater type T has a two-stage thermostat which automatically switches from minimum to maximum wattages as needed. Heater type TZ is furnished with an additional 0-60 minute mechanical timer that provides manual oper-ation at maximum wattage during occupied periods, then resumes normal two-stage control.

• Installation Flexibility: The heater can be recessed in a 2-inch by 3-inch stud wall or surface mounted without the use of adapters.

Applications• Entryways

• Fire Station Changing Areas

• Offices

• Reception Areas

• Restrooms

Standard Construction FeaturesHeating Elements – Stitched ribbon-type element.

Outlet Grille – The 20-gauge steel grille has a polyester powder paint finish available in white, almond, or optional stainless steel front cover.

Built-in Controls – Automatic reset thermal cutout prevents overheating.

Fan Motor – Two-speed whisper-quiet squirrel-cage fan oper-ates at 33 dBA with 35 CFM and 42.5 dBA with 70 CFM.

Installation Requirements – The air outlet should be installed a minimum of 12-inches above floors.

Rough In Dimensions – All heaters: 11-/8” wide x 15-1/2” high x 2” deep.

Heater Listing

(Shown with optional thermostat & timer)

Remote Room Thermostat – See pages 111-112.

Watts Volts(1 Phase)

TotalAmps (1)

CFM Maximum AirTemperature

Weightlb (kg)

Catalog NumberMinimum Maximum Minimum Maximum

- 1500 120 13.0 - 70 68 (38) 14 (6) HX-935U01500B

750 1500 120 13.0 35 70 68 (38) 14 (6) HX-935U01500B-T

750 1500 120 13.0 35 70 68 (38) 14 (6) HX-935U01500B-TZ

- 1500/1125 240/208 6.7/5.9 - 70 68/51 (38/28) 14 (6) HX-935U01500V

750/563 1500/1125 240/208 6.7/5.9 35 70 68/51 (38/28) 14 (6) HX-935U01500V-T

750/563 1500/1125 240/208 6.7/5.9 35 70 68/51 (38/28) 14 (6) HX-935U01500V-TZ

295 mm11 5/8"

51 mm2"

102 mm4"419 mm

16 1/2"

335 mm13 3/16"

Recessed Wall-Mounted

419 mm16 1/2"

76 mm3"

51 mm2"

51 mm2"

38 mm1 1/2"

335 mm13 3/16"

19 mm3/4"

176 mm6 15/16"

102 mm4"

109 mm4 5/16"

Front View Side View

Bottom View

KOE Ø22 mmKOE Ø7/8"

KOE Ø22 mmKOE Ø7/8"

KOE Ø6.4 mmKOE Ø1/4"

378 mm14 7/8"

(1) Total Amps = Heating element amps and motor amps.Add W to end of catalog number for white finish, A for almond or SS for custom stainless steel front cover.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Standard Special Colors

Page 58: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

57

940 SeriesHybrid Convection Wall Heater

The 940 Series wall heater is a unique design and offers two levels of heating. The first level is convection heat with a second level of forced-air heating. This feature combines the quiet operation of convection heating for normal heating conditions and when needed a boost to forced-air heating with greater heating capacity, all in the same unit. This is well suited for con-dominiums when an up scale appearance is required.• Unique Temperature Control: Built-in digital thermostat with full mod-

ulating power for convection to fan-forced heating. The power level is automatically managed by the thermostat through the full output of the heater. The electronic thermostat displays actual room temperature, with adjustable temperature settings between 50 and 95°F (10 to 35°C). When the heater is on, four graduated lines indicate the power level on the display.

• Manual Power Boost: To override the automatic temperature control the heater can be easily switched into the boost heat level using the built-in timer. Boost power can be set for 5, 10, 15, 20, 25 or 30 minutes.

• Mounting: The heater can be recessed in a 2-inch by 3-inch stud wall, or surface mounted with or without a color matched surface mounting box.

Standard Construction FeaturesHeating Elements – Instant heat nickel-chrome coil resistant wire element.

Outlet Grille – Heavy cast aluminum front cover with steel bar inlet and outlet grilles has a polyester powder paint finish available in white or almond.

Built-in Controls – Digital display electronic thermostat with timer, automatic reset thermal cutout, overtemperature warning light, temperature sensor and LED night light with on-off switch.

Fan motor – Whisper-quiet squirrel-cage fan with factory-lubricat-ed motor.

Installation Requirements – Maintain a minimum of 4-inches (102 mm) clearance below heater, 1-inch (25 mm) to adjacent walls and 48-inches (1219 mm) in front of heater.Rough In Dimensions – All heaters: 18-3/8” wide x 13-5/8” high x 2-3/4” deep.

Code Description

D3 Disconnect Switch, 277V, Double-pole, 16 Amp

Catalog Number Description

940-213895 Cast Aluminum Surface Mounting BoxStandard colors – Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors – See inside of back cover for color codes to be added to end of catalog number.

Standard colors – Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors – See inside of back cover for color codes to be added to end of catalog number.

Watts Volts(1 Ph) Amps Weight

lb (kg)CatalogNumber

1500 120 12.5 22.8 (10.3) HX-940U01500B

2000 240 8.3 22.8 (10.3) HX-940U02000J

Applications• Entryways

• Fire Station Changing Areas

• Offices

• Reception Areas

• Restrooms

Heater Listing

Factory Built-in Options

Field-Installed Options

550 mm21 5/8"

38 mm1 1/2"

369 mm14 1/2"

42 mm1 5/8"

70 mm2 3/4" 15 mm

9/16"

380 mm15"

337 mm13 1/4"

380 mm15"

42 mm1 5/8"

550 mm21 5/8"

470 mm18 1/2"

112 mm4 7/16"

20 mm3/4"

332 mm13 1/16"

350 mm13 3/4"

140 mm5 1/2"

Recessed

Front View Side ViewBottom View

Wall-Mounted

KOE Ø22 mmKOE Ø7/8"

KOE Ø22 mmKOE Ø7/8"

KOE Ø6.4 mmKOE Ø1/4"

Standard Special Colors

Page 59: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

58

934 Series Wall Heater

The 934 Series wall heater is designed for recessed mounting into shallow 2-inch by 3-inch stud walls. It provides heat in a quiet, efficient manner. Single units can heat small areas and multiple heaters can be used in large or odd-shaped rooms.• Mounting Options: Units can be surface (with option-

al box) or recessed mounted, vertically or horizon-tally, in one of four positions. A tapered recess box assures a tight fit when mounted into the wall.

Standard Construction FeaturesHeating Elements – Steel finned tubular elements.

Outlet Grille – The louvered front grille is made from 22-gauge steel with rounded corners. The grille is finished with an epoxy/polyester powder paint in white or almond.

Built-in Controls – Automatic reset thermal cutout.

Fan Motor – Quiet, permanently lubricated axial fan operates at 38 dBA at 40 CFM for models up to 1000 W and 41.3 dBA at 80 CFM for all models rated above 1000 W.

Installation Requirements - The air outlet should be installed a minimum of ten inches above floors.

Rough In Dimensions – All heaters: 7-3/16” wide x 14-1/8” high x 3” deep.

Field-Installed Options (shipped loose for field installation into heater)

Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Factory Built-in Options

Applications• Breezeways

• Entryways

• Restrooms

Remote Room Thermostat – See pages 111-112.

Code DescriptionD3 Disconnect Switch, 277V, Double-pole, 16 Amp

T1 Tamperproof Thermostat, Single-pole, 25 Amp

T2 Tamperproof Thermostat, Double-pole, 25 Amp with off position

T5 Adjustable Thermostat, Single-pole, 25 Amp

T6 Adjustable Thermostat, Double-pole, 25 Amp with off position

CatalogNumber Description

934-124647 Surface Mounting Box

934-124648 Adjustable Thermostat Kit, Single-pole, 25 Amp

934-124649 Tamperproof Thermostat Kit, Single-pole, 25 Amp

934-124650 Adjustable Thermostat Kit, Double-pole, 25 Amp with off position

934-124651 Tamperproof Thermostat Kit, Double-pole, 25 Amp with off position

• Small Offices

• Storage Rooms

Standard Special Colors

Page 60: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

59

Mounting positions available. Pictures showing front panel. Directional vane air flow.

1 2 3 4

OVS OVSP

Mounting Positions Available

934 Series Wall Heater

Heater Listing

(1) Total Amps = Heating element amps and motor amps.Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Watts Volts(1 Phase)

TotalAmps (1) CFM

Approximate AirTemperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

500 120 4.6 40 40 (22) 9 (4) HX-934U00500B

500/375 240/208 2.3/2.0 40 40/30 (22/17) 9 (4) HX-934U00500V

750 120 6.7 40 60 (33) 9 (4) HX-934U00750B

750/563 240/208 3.3/2.9 40 60/45 (33/25) 9 (4) HX-934U00750V

1000 120 8.7 40 80 (44) 9 (4) HX-934U01000B

1000/750 240/208 4.5/3.8 40 80/60 (44/33) 9 (4) HX-934U01000V

1250 120 10.8 80 50 (28) 9 (4) HX-934U01250B

1250/938 240/208 5.4/4.7 80 50/37 (28/21) 9 (4) HX-934U01250V

1500 120 12.9 80 60 (33) 9 (4) HX-934U01500B

1500/1125 240/208 6.5/5.6 80 60/45 (33/25) 9 (4) HX-934U01500V

2000 208 9.8 80 80 (44) 9 (4) HX-934U02000C

2000/1500 240/208 8.5/7.4 80 80/60 (44/33) 9 (4) HX-934U02000V

76 mm3"

182 mm7 3/16"

358 mm14 1/8"

406 mm16"

179 mm7 1/16" 76 mm

3" 206 mm8 1/8"

406 mm16"

206 mm8 1/8"

2" X 3"Stud Wall

Heater

Grille

Surface Box

WallOpening

355 mm13 7/8"

32 mm1 1/4"

STU

D L

INE

/ M

ON

TAN

T5/

8

1/2

5/8

1/2

STU

D L

INE

/ M

ON

TAN

T5/

8

1/2

5/8

1/2

STU

D L

INE

/ M

ON

TAN

T5/

8

1/2

5/8

1/2

76 mm3"

182 mm7 3/16"

358 mm14 1/8"

406 mm16"

179 mm7 1/16" 76 mm

3" 206 mm8 1/8"

406 mm16"

206 mm8 1/8"

2" X 3"Stud Wall

Heater

Grille

Surface Box

WallOpening

355 mm13 7/8"

32 mm1 1/4"

STU

D L

INE

/ M

ON

TAN

T5/

8

1/2

5/8

1/2

STU

D L

INE

/ M

ON

TAN

T5/

8

1/2

5/8

1/2

STU

D L

INE

/ M

ON

TAN

T5/

8

1/2

5/8

1/2

Page 61: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

60

930 SeriesRegister Wall Heater

The 930 Series register wall heater is ideal for use as a primary heat source in small areas or as supplemental heat in more spacious areas. Multiple heaters can be used to effectively heat large or odd-shaped rooms.• Installation Options: Units are designed for recessed

mounting into shallow 2-inch by 3-inch stud walls or surface mounting with the use of an optional box.

• Safety: Finned tubular elements provide electrical isolation from accidental contact.

• Temperature Control: An optional thermostat can be installed in the heater or a remote thermostat can be used.

Applications• Hallways

Standard Construction FeaturesHeating Elements – Steel finned tubular elements.

Outlet Grille – The louvered front grille is made from 20-gauge steel. The grille is finished with an epoxy/polyester powder paint in white or almond.

Built-in Controls – Automatic reset thermal cutout and over-temperature warning light.

Fan Motor – Quiet, factory lubricated fan operates at 38 dBA at 40 CFM for models up to 1,000 W and 41.3 dBA at 80 CFM for all models rated above 1,000 W.

Installation Requirements – The air outlet should be installed a minimum of ten inches above vinyl floors.

Rough In Dimensions – All heaters: 14-1/8” wide x 7-3/16” high x 3” deep.

Field-Installed Options (shipped loose for field installation into heater)

Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Double-pole thermostats include positive off feature.

Factory Built-in Options

Remote Room Thermostat – See page

(Shown with optional built-in thermostat)

CatalogNumber Description

930-166766 Surface Mounting Box

930-166767 Adjustable Thermostat Kit, Single-pole, 25 Amp

930-166768 Tamperproof Thermostat Kit, Single-pole, 25 Amp

930-166769 Adjustable Thermostat Kit, Double-pole, 25 Amp with off position

930-166770 Tamperproof Thermostat Kit, Double-pole, 25 Amp with off position

Code Description

D3 Disconnect Switch, 277V, Double-pole, 16 Amp

T1 Tamperproof Thermostat, Single-pole, 25 Amp

T2 Tamperproof Thermostat, Double-pole, 25 Amp with off position

T5 Adjustable Thermostat, Single-pole, 25 Amp

T6 Adjustable Thermostat, Double-pole, 25 Amp with off position

• Restrooms • Stairwells

Standard Special Colors

Page 62: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

61

Heater Listing

(1) Total Amps = Heating element amps and motor amps.Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

930 SeriesRegister Wall Heater

76 mm3"

76 mm3"

182 mm7 3/16"

358 mm14 1/8" 407 mm

16"

206 mm8 1/8"

76 mm3"

407 mm16"

206 mm8 1/8"

355 mm13 7/8"

2" X 3"Stud Wall

Heater

Grille

Surface Box

WallOpening

179 mm7 1/16"

34 mm1 5/16"

STUD LINE / MONTANT

5/81/2

5/81/2

STUD LINE / MONTANT

5/81/2

5/81/2

Watts Volts(1 Phase)

TotalAmps (1) CFM

Approximate Air Temperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

500 120 4.6 40 40 (22) 9 (4) HX-930U00500B

500/375 240/208 2.3/2.0 40 40/30 (22/17) 9 (4) HX-930U00500V

750 120 6.7 40 60 (33) 9 (4) HX-930U00750B

750/563 240/208 3.3/2.9 40 60/45 (33/25) 9 (4) HX-930U00750V

1000 120 8.7 40 80 (44) 9 (4) HX-930U01000B

1000/750 240/208 4.5/3.8 40 80/60 (44/33) 9 (4) HX-930U01000V

1250 120 10.8 80 50 (28) 9 (4) HX-930U01250B

1250/938 240/208 5.4/4.7 80 50/37 (28/21) 9 (4) HX-930U01250V

1500 120 12.9 80 60 (33) 9 (4) HX-930U01500B

1500/1125 240/208 6.5/5.6 80 60/45 (33/25) 9 (4) HX-930U01500V

2000 208 9.8 80 80 (44) 9 (4) HX-930U02000C

2000/1500 240/208 8.5/7.4 80 80/60 (44/33) 9 (4) HX-930U02000V

Page 63: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

62

The 922 Series cabinet heater offers a unique combination of quality, efficiency, reliability and flexibility. The attrac-tive cabinet design blends into any commercial decor.• Mounting Options: The cabinet heater can be mounted

on the floor, wall or ceiling. It can also be recessed into the wall or ceiling as required. Twelve air inlet and out-let combinations are available.

• Simplified Maintenance: The insulated front panel is hinged to allow for easy access.

• Quiet Operation: The blower wheel is mounted directly on the motor shaft to reduce the noise level.

• Fresh Air Inlet: Manual or optional power-operated inlet allows fresh air to enter through the rear of the heater and mix with re-circulated room air.

Applications• Classrooms

• Hallways

• Meeting Rooms

• Lobbies

• Stairways

• Corridors

• Waiting Rooms

• Entry Ways

Standard Construction FeaturesHeating Elements – Industrial grade steel finned tubular ele-ments.

Housing – Cabinet is constructed of 18-gauge steel with an epoxy/polyester powder paint finish in white or almond.

Outlet Grille – An extruded architectural style aluminum grille discourages tampering with the heating element. The grille can be field converted for front or top air discharge.

Built-in Controls – Automatic reset thermal cutout and fan delay. Power fusing is supplied for heaters over 48 amps.

Fan Motor – The squirrel cage fan is beltless and two-speed, operating at 48 dBA at low speed and 50 dBA at high speed. Fan motors have permanently lubricated sleeve bearings for trouble-free service.

Installation Requirements – For best performance, do not install cabinet heaters above recommended maximum mounting height of ten feet.

Rough In Dimensions – Recess mounting only: Heater Length + 1” wide x 27” high x 12” deep.

922 SeriesCabinet Wall Heater

Standard Special Colors

Page 64: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

63

922 SeriesCabinet Wall Heater

Field-Installed Options (shipped loose for field installation into heater)

(1) Do not install built-in thermostat with these options.(2) To obtain the minimum ratings, it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” two-speed motor with high/low relay-24 Volt. The “N2” can be con-nected to a remote two-stage, wall-mounted thermostat or field-furnished low voltage device for maximum/minimum control.(3) Option N2 is required for two-stage remote thermostat operation.(4) When choosing Option T7; A1, A2, N1, N2, R1, R2 & T1 are unavailable. * Additional kW/standard cabinet size combinations are available.

Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.

Mounting Hole Positions

Factory Built-in Options

Mounting Applications

Remote Room Thermostat – See pages 111-112.

Code Description

A1 Fresh Air Inlet (1)

A2 Power Operated Fresh Air Inlet (1)

D1 Disconnect Switch 600V, Three-pole, 32 Amp

D2 Disconnect Switch 600V, Three-pole, 64 Amp

G Fusing

M Manual Reset

N1 2-Speed Motor w/High-Low Switch (2)

N2 2-Speed Motor w/High-Low Relay-24 (1) (2) (3)

R1 24V Relay

R2 24V Relay with Transformer

S1 On/Auto Fan Relay-24V

S2 On/Standby 24V Relay with Transformer

S3 Standby Heating Switch with Transformer

S4 On Standby Heating Switch

T1 Tamperproof Thermostat, 1-Stage, Single-pole

T7 Tamperproof Thermostat, 2-Stage (4)

CatalogNumber Description

HeaterLength

In. (mm)

922-124530

Sub Base

28 (711)

922-124531 48 (1219)

922-124532 66 (1676)

922-124533 80 (2032)

922-124534

Recess Trim Kit

28 (711)

922-124535 48 (1219)

922-124536 66 (1676)

922-124537 80 (2032)

922-124538PPermanent/Washable

Air Filters(Wall Installation Only)

28 (711)

922-124539P 48 (1219)

922-124540P 66 (1676)

922-124541P 80 (2032)

922-124538Replaceable Throwaway

Air Filters(Wall Installation Only)

28 (711)

922-124539 48 (1219)

922-124540 66 (1676)

922-124541 80 (2032)

922-218265Smooth Finish on Heater

Back Plate KitHeater Length In (mm)

28 (711)

922-218266 48 (1219)

922-218267 66 (1676)

922-218268 80 (2032)

922-224750 Tamperproof Single-pole thermostat kit

Front View Bottom View

KOE Ø28-Ø22 mmKOE Ø1 1/8"-Ø7/8"

KOE Ø6.4 mmKOE Ø1/4"

KOE Ø44-Ø35 mmKOE Ø1 3/4"-Ø1 3/8"

Length +25.4 mm (1")

686 mm 27"

660 mm 26"

53 mm 2 1/16"

84 mm 3 5/16"

39 mm 1 1/2"

187 mm 7 3/8"

64 mm 2 1/2"

51 mm 2"

157 mm 6 3/16"

Wall Opening

Installation with Recess Trim KitInstallation with Sub-Base

Recessed Semi-Recessed SurfaceInstallation254 mm

10"

51 mm 2"

51 mm 2"

51 mm 2"

A1

B1

C1

D1

A2

C2

B2

D2

A3

C3

B3

D3

Ceiling

Wall

Semi-Recessed

D Type Mounting Only

Recessed

Semi-Recessed

D Type Mounting Only

Recessed

Top BottomCeiling

Mounting

Wall Mouting

79 Length

Wa�s Length2 @ 6 kW 356 mm6 @ 12 kW 864 mm15 @ 18 kW 1322 mm20 @ 24 kW 1677 mm

327

255

Length3”

12.8”

10”

Watts Length In (mm)

2 - 6 kW 14 (356)6 - 12 kW 34 (864)15 - 18 kW 52 (1322)20 - 24 kW 66 (1677)

Page 65: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

64

Heater Listing

(1) To obtain the minimum ratings it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” two-speed motor with high/low relay-24 volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field furnished low voltage device for maximum/minimum control. (2) Total Amps = Heating element amps and motor amps.Other voltages available. Consult factory.Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Specify mounting application code when ordering (see page 19).

Watts (1)Volts Phase

Total Amps (2) CFM Approximate AirTemp. Rise °F (°C)

Heater LengthIn. (mm)

WeightLbs (kg)

CatalogNumberMax. Min. Max. Min. Max. Min

2000 1333

208 1 11.0 7.8 250 200 26 (14) 28 (711) 115 (52) HX-922U02000C208 3 7.0 5.1 250 200 26 (14) 28 (711) 115 (52) HX-922U02000D240 1 9.7 7.0 250 200 26 (14) 28 (711) 115 (52) HX-922U02000J240 3 6.2 2.6 250 200 26 (14) 28 (711) 115 (52) HX-922U02000K277 1 8.6 6.2 250 200 26 (14) 28 (711) 115 (52) HX-922U02000N480 3 3.8 3.0 250 200 26 (14) 28 (711) 115 (52) HX-922U02000U

3000 1000

208 1 15.8 6.2 250 200 38 (21) 28 (711) 115 (52) HX-922U03000C208 3 9.7 4.2 250 200 38 (21) 28 (711) 115 (52) HX-922U03000D240 1 13.9 5.6 250 200 38 (21) 28 (711) 115 (52) HX-922U03000J240 3 8.6 3.8 250 200 38 (21) 28 (711) 115 (52) HX-922U03000K277 1 12.2 5.0 250 200 38 (21) 28 (711) 115 (52) HX-922U03000N480 3 5.0 2.6 250 200 38 (21) 28 (711) 115 (52) HX-922U03000U

4000 2667

208 1 20.6 14.2 250 200 51 (28) 28 (711) 115 (52) HX-922U04000C208 3 12.5 8.8 250 200 51 (28) 28 (711) 115 (52) HX-922U04000D240 1 18.1 12.5 250 200 51 (28) 28 (711) 115 (52) HX-922U04000J240 3 11.0 7.8 250 200 51 (28) 28 (711) 115 (52) HX-922U04000K277 1 15.8 11.0 250 200 51 (28) 28 (711) 115 (52) HX-922U04000N480 3 6.2 4.6 250 200 51 (28) 28 (711) 115 (52) HX-922U04000U

5000 3333

208 1 25.4 17.4 250 200 64 (36) 28 (711) 115 (52) HX-922U05000C208 3 15.3 10.7 250 200 64 (36) 28 (711) 115 (52) HX-922U05000D240 1 22.2 15.3 250 200 64.(36) 28 (711) 115 (52) HX-922U05000J240 3 13.4 9.5 250 200 64 (36) 28 (711) 115 (52) HX-922U05000K277 1 19.4 13.4 250 200 64 (36) 28 (711) 115 (52) HX-922U05000N480 3 7.4 5.4 250 200 64 (36) 28 (711) 115 (52) HX-922U05000U

922 SeriesCabinet Wall Heater

Front View Bottom View

KOE Ø28-Ø22 mmKOE Ø1 1/8"-Ø7/8"

KOE Ø6.4 mmKOE Ø1/4"

KOE Ø44-Ø35 mmKOE Ø1 3/4"-Ø1 3/8"

Length +25.4 mm (1")

686 mm 27"

660 mm 26"

53 mm 2 1/16"

84 mm 3 5/16"

39 mm 1 1/2"

187 mm 7 3/8"

64 mm 2 1/2"

51 mm 2"

157 mm 6 3/16"

Wall Opening

Installation with Recess Trim KitInstallation with Sub-Base

Recessed Semi-Recessed SurfaceInstallation254 mm

10"

51 mm 2"

51 mm 2"

51 mm 2"

A1

B1

C1

D1

A2

C2

B2

D2

A3

C3

B3

D3

Ceiling

Wall

Semi-Recessed

D Type Mounting Only

Recessed

Semi-Recessed

D Type Mounting Only

Recessed

Top BottomCeiling

Mounting

Wall Mouting

Page 66: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

65

922 SeriesCabinet Wall Heater

(1) To obtain the minimum ratings it is necessary to add the optional “N1” two-speed motor with high/low switch for manual operation or option “N2” two-speed motor with high/low relay-24 volt. The “N2” can be connected to a remote two-stage, wall-mounted thermostat or field furnished low voltage device for maximum/ minimum control.(2) Total Amps = Heating element amps and motor amps.Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number. Specify mounting application code when ordering (see page 19).

Heater Listing (continued)Watts (1)

Volts PhaseTotal Amps (2) CFM Approximate Air

Temp. Rise °F (°C)Heater Length

In. (mm)WeightLbs (kg)

CatalogNumberMax. Min. Max. Min. Max. Min

6000 4000

208 1 30.2 20.6 250 200 77 (43) 28 (711) 115 (52) HX-922U06000C208 3 18.1 12.5 250 200 77 (43) 28 (711) 115 (52) HX-922U06000D240 1 26.4 18.1 250 200 77 (43) 28 (711) 115 (52) HX-922U06000J240 3 15.8 11.0 250 200 77 (43) 28 (711) 115 (52) HX-922U06000K277 1 23.1 15.8 250 200 77 (43) 28 (711) 115 (52) HX-922U06000N480 3 8.6 6.2 250 200 77 (43) 28 (711) 115 (52) HX-922U06000U

8000 4000

208 1 41.3 22.0 500 400 51 (28) 48 (1219) 146 (66) HX-922U08000C208 3 25.0 13.9 500 400 51 (28) 48 (1219) 146 (66) HX-922U08000D240 1 36.1 19.5 500 400 51 (28) 48 (1219) 146 (66) HX-922U08000J240 3 22.0 12.4 500 400 51 (28) 48 (1219) 146 (66) HX-922U08000K277 1 31.7 17.2 500 400 51 (28) 48 (1219) 146 (66) HX-922U08000N480 3 12.4 7.6 500 400 51 (28) 48 (1219) 146 (66) HX-922U08000U

10000 5000

208 1 50.9 26.8 500 400 64 (36) 48 (1219) 146 (66) HX-922U10000C208 3 30.6 16.7 500 400 64 (36) 48 (1219) 146 (66) HX-922U10000D240 1 44.5 23.6 500 400 64 (36) 48 (1219) 146 (66) HX-922U10000J240 3 26.9 14.8 500 400 64 (36) 48 (1219) 146 (66) HX-922U10000K277 1 38.9 20.9 500 400 64 (36) 48 (1219) 146 (66) HX-922U10000N480 3 14.8 8.8 500 400 64 (36) 48 (1219) 146 (66) HX-922U10000U

12000 6000

208 1 60.5 31.6 500 400 77 (43) 48 (1219) 146 (66) HX-922U12000C208 3 36.1 19.5 500 400 77 (43) 48 (1219) 146 (66) HX-922U12000D240 1 52.8 27.8 500 400 77 (43) 48 (1219) 146 (66) HX-922U12000J240 3 31.7 17.3 500 400 77 (43) 48 (1219) 146 (66) HX-922U12000K277 1 46.1 24.5 500 400 77 (43) 48 (1219) 146 (66) HX-922U12000N480 3 17.2 10.0 500 400 77 (43) 48 (1219) 146 (66) HX-922U12000U

15000 10000

208 1 76.3 52.3 750 600 63 (35) 66 (1677) 210 (96) HX-922U15000C208 3 45.9 32.0 750 600 63 (35) 66 (1677) 210 (96) HX-922U15000D240 1 66.7 45.9 750 600 63 (35) 66 (1677) 210 (96) HX-922U15000J240 3 40.3 28.3 750 600 63 (35) 66 (1677) 210 (96) HX-922U15000K480 3 22.3 16.2 750 600 63 (35) 66 (1677) 210 (96) HX-922U15000U

18000 12000

208 1 90.7 61.9 750 600 77 (43) 66 (1677) 210 (96) HX-922U18000C208 3 54.2 37.5 750 600 77 (43) 66 (1677) 210 (96) HX-922U18000D240 1 79.2 54.2 750 600 77 (43) 66 (1677) 210 (96) HX-922U18000J240 3 47.5 33.1 750 600 77 (43) 66 (1677) 210 (96) HX-922U18000K480 3 25.9 18.6 750 600 77 (43) 66 (1677) 210 (96) HX-922U18000U

20000 13333

208 1 101.8 69.7 1000 800 64 (36) 80 (2032) 240 (109) HX-922U20000C208 3 61.1 42.6 1000 800 64 (36) 80 (2032) 240 (109) HX-922U20000D240 1 88.9 61.2 1000 800 64 (36) 80 (2032) 240 (109) HX-922U20000J240 3 53.7 37.7 1000 800 64 (36) 80 (2032) 240 (109) HX-922U20000K480 3 29.7 21.7 1000 800 64 (36) 80 (2032) 240 (109) HX-922U20000U

24000 16000

208 3 72.2 50.1 1000 800 77 (43) 80 (2032) 240 (109) HX-922U24000D240 1 105.6 72.3 1000 800 77 (43) 80 (2032) 240 (109) HX-922U24000J240 3 63.3 44.1 1000 800 77 (43) 80 (2032) 240 (109) HX-922U24000K480 3 34.5 24.9 1000 800 77 (43) 80 (2032) 240 (109) HX-922U24000U

Page 67: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

66

Downward Discharge Uniform Circulation

936 Series Surface Mounting

937 Series Recessed Mounting

The 936/937 Series ceiling heaters are designed for com-mercial applications. 936 Series heaters are designed for surface mounting and can be adapted for T-Bar installation with an optional kit. The 937 Series heater is designed for recessed mounting and installation into 2-feet by 2-feet ceiling grids. The 937 comes with a built-in flange; an addi-tional trim ring kit is not required.• Enhanced Performance: These heaters set new industry

standards with ratings up to 10,000 W and 600 CFM in single and three-phase 208, 240 and 480 voltages.

• Increased Comfort: The side draw-through inlet with down discharge promotes circulation within the space for uniform temperatures and increased comfort.

Standard Construction FeaturesHeating Elements – Stainless steel tubular elements with aluminum fins.

Outlet Grille – The grille is made of 20-gauge galvanized steel with a flat ribbon wire outlet grille and is finished with a polyester powder paint in white or almond.

Built-in Controls – Automatic reset thermal cutout and fan delay relay.

Fan Motor – Quiet, direct drive aluminum fan and totally enclosed motor with lifetime lubricated ball bearings.

Installation Requirements – For best performance, ceiling heaters should be installed between 8 and 12-feet above the floor.

Rough In Dimensions – CDIR Only: 23” wide x 23” high x 6” deep

Applications• Classrooms

• Day Care

• Entryways

• Guard Houses

• Hallways

• Lobbies

• Offices

• Reception Areas

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

Add W to end of catalog number for white finish or add A for almond finish.

Remote Room Thermostat – See page

Code Description

D1 Disconnect Switch 600V, Three-pole, 32 Amp

D2 Disconnect Switch 600V, Three-pole, 64 Amp

D3 Disconnect Switch 277V, Double-pole, 16 Amp

R1 24V Control Relay

R2 24V Control Relay with Transformer

S3 Summer Fan Switch and Pilot Light

S5 Summer Fan 24V Relay for Remote Switching and Pilot Light (Switch not included)

S6 Summer Fan 240V Relay for Remote Switching and Pilot Light (Switch not included)

T1 Tamperproof Thermostat

X 120V Control, fused secondary and grounded

CatalogNumber Description

936-158478 Tamperproof Thermostat Kit

936-218269 24V Control Relay Kit

936-229004 Disconnect Switch Kit, 16 Amp, 277V, Double-pole

936-158479 T-Bar Adaptor for CDI surface mounting 2000 through 5000 watt heaters

936-277095 T-Bar Adaptor for CDI surface mounting 7500-10000 watt heaters

936/937 SeriesFan-Forced Ceiling Heater

Standard Special Colors

• Restrooms

• Vestibules

• Workshops

Page 68: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

67

936/937 SeriesFan-Forced Ceiling Heater

936 Series2,000-5,000 WattSurface Mounting

937 Series2,000-5,000 Watt

Recessed Mounting

936 Series7,500-10,000 WattSurface Mounting

936 Series Surface Mountingfor 2,000 to 5,000 Watt Heaters

937 Series Recessed Mounting

Hanger Clips

416 mm16 3/8"

416 mm16 3/8"

175 mm6 7/8"

221 mm8 3/4"

75 mm3"

KOE Ø28/Ø22 mmKOE Ø1 1/8/Ø7/8"

New Mounting Bracket

Cover Screwson Front

44 mm1 3/4"

936 Series Surface Mountingfor 7,500 to 10,000 Watt Heaters

223 mm8 3/4"

167 mm6 9/16"

70 mm2 3/4"

572 mm22 1/2"

95 mm3 3/4"

25 mm1"

600 mm23 5/8"

600 mm23 5/8"

65 mm2 9/16" 55 mm

2 3/16"46 mm1 13/16"

110 mm4 5/16"

KOE Ø28/Ø22 mmKOE Ø1/8/Ø7/8"

KOE Ø6.4 mmKOE Ø1/4"

77 mm3"

110 mm4 5/16"

567 mm22 5/16"

567 mm22 5/16"

169 mm6 5/8"

215 mm8 1/2"

KOE Ø28/Ø22 mmKOE Ø1/8/Ø7/8"

KOE Ø6.4 mmKOE Ø1/4"

34 mm1 5/16"

94 mm3 11/16"

60 mm2 3/8"

46 mm1 13/16"

Page 69: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

68

936/937 SeriesFan-Forced Ceiling Heater

936 Series Surface Mounting Heater Listing

(1) Total Amps = Heating element amps and motor amps.Add W to end of catalog number for white finish or add A for almond finish.Special or custom colors - See inside back cover for color codes to be added to the end of the catalog number.

Watts Volts Phase Total Amps (1) CFM

Approximate Air Temperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

2000

208 1 10.3 310 20 (11) 25 (11.3) HX-936U02000C208 3 6.3 310 20 (11) 25 (11.3) HX-936U02000D240 1 9.0 310 20 (11) 25 (11.3) HX-936U02000J240 3 5.5 310 20 (11) 25 (11.3) HX-936U02000K277 1 7.9 310 20 (11) 25 (11.3) HX-936U02000N480 1 4.9 310 20 (11) 25 (11.3) HX-936U02000T480 3 3.1 310 20 (11) 25 (11.3) HX-936U02000U

3000

208 1 15.1 310 30 (17) 25 (11.3) HX-936U03000C208 3 9.0 310 30 (17) 25 (11.3) HX-936U03000D240 1 13.2 310 30 (17) 25 (11.3) HX-936U03000J240 3 7.9 310 30 (17) 25 (11.3) HX-936U03000K277 1 11.5 310 30 (17) 25 (11.3) HX-936U03000N480 1 7.0 310 30 (17) 25 (11.3) HX-936U03000T480 3 4.3 310 30 (17) 25 (11.3) HX-936U03000U

4000

208 1 19.9 310 41 (23) 25 (11.3) HX-936U04000C208 3 11.8 310 41 (23) 25 (11.3) HX-936U04000D240 1 17.4 310 41 (23) 25 (11.3) HX-936U04000J240 3 10.3 310 41 (23) 25 (11.3) HX-936U04000K277 1 15.1 310 41 (23) 25 (11.3) HX-936U04000N480 1 9.0 310 41 (23) 25 (11.3) HX-936U04000T480 3 5.5 310 41 (23) 25 (11.3) HX-936U04000U

5000

208 1 24.7 310 51 (28) 25 (11.3) HX-936U05000C208 3 14.6 310 51 (28) 25 (11.3) HX-936U05000D240 1 21.5 310 51 (28) 25 (11.3) HX-936U05000J240 3 12.7 310 51 (28) 25 (11.3) HX-936U05000K277 1 18.8 310 51 (28) 25 (11.3) HX-936U05000N480 1 11.1 310 51 (28) 25 (11.3) HX-936U05000T480 3 6.7 310 51 (28) 25 (11.3) HX-936U05000U

7500

208 1 36.8 600 39 (22) 34 (15.4) HX-936U07500C208 3 21.5 600 39 (22) 34 (15.4) HX-936U07500D240 1 32.0 600 39 (22) 34 (15.4) HX-936U07500J240 3 18.7 600 39 (22) 34 (15.4) HX-936U07500K277 1 27.8 600 39 (22) 34 (15.4) HX-936U07500N480 1 16.3 600 39 (22) 34 (15.4) HX-936U07500T480 3 9.7 600 39 (22) 34 (15.4) HX-936U07500U

9900208 1 48.0 600 53 (29) 34 (15.4) HX-936U09900C208 3 28.0 600 53 (29) 34 (15.4) HX-936U09900D

10000

240 1 42.4 600 53 (29) 34 (15.4) HX-936U10000J240 3 24.8 600 53 (29) 34 (15.4) HX-936U10000K277 1 36.8 600 53 (29) 34 (15.4) HX-936U10000N480 1 21.5 600 53 (29) 34 (15.4) HX-936U10000T480 3 12.7 600 53 (29) 34 (15.4) HX-936U10000U

Page 70: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

69

936/937 SeriesFan-Forced Ceiling Heater

937 Series Recessed Mounting Heater Listing

(1) Total Amps = Heating element amps and motor amps.Add W to end of catalog number for white finish or add A for almond finish.Special or custom colors - See inside back cover for color codes to be added to the end of the catalog number.

Watts Volts Phase TotalAmps (1) CFM

Approximate Air Temperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

2000

208 1 10.3 310 20 (11) 31 (14) HX-937U02000C

208 3 6.3 310 20 (11) 31 (14) HX-937U02000D

240 1 9.0 310 20 (11) 31 (14) HX-937U02000J

240 3 5.5 310 20 (11) 31 (14) HX-937U02000K

277 1 7.9 310 20 (11) 31 (14) HX-937U02000N

480 1 4.9 310 20 (11) 31 (14) HX-937U02000T

480 3 3.1 310 20 (11) 31 (14) HX-937U02000U

3000

208 1 15.1 310 30 (17) 31 (14) HX-937U03000C

208 3 9.0 310 30 (17) 31 (14) HX-937U03000D

240 1 13.2 310 30 (17) 31 (14) HX-937U03000J

240 3 7.9 310 30 (17) 31 (14) HX-937U03000K

277 1 11.5 310 30 (17) 31 (14) HX-937U03000N

480 1 7.0 310 30 (17) 31 (14) HX-937U03000T

480 3 4.3 310 30 (17) 31 (14) HX-937U03000U

4000

208 1 19.9 310 41 (23) 31 (14) HX-937U04000C

208 3 11.8 310 41 (23) 31 (14) HX-937U04000D

240 1 17.4 310 41 (23) 31 (14) HX-937U04000J

240 3 10.3 310 41 (23) 31 (14) HX-937U04000K

277 1 15.1 310 41 (23) 31 (14) HX-937U04000N

480 1 9.0 310 41 (23) 31 (14) HX-937U04000T

480 3 5.5 310 41 (23) 31 (14) HX-937U04000U

5000

208 1 24.7 310 51 (28) 31 (14) HX-937U05000C

208 3 14.6 310 51 (28) 31 (14) HX-937U05000D

240 1 21.5 310 51 (28) 31 (14) HX-937U05000J

240 3 12.7 310 51 (28) 31 (14) HX-937U05000K

277 1 18.8 310 51 (28) 31 (14) HX-937U05000N

480 1 11.1 310 51 (28) 31 (14) HX-937U05000T

480 3 6.7 310 51 (28) 31 (14) HX-937U05000U

Page 71: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

70

The 931 Series ceiling heater is designed for commercial use in areas where no wall space is available. It provides supplemen-tal heat to prevent cold drafts or wide temperature swings. • Extended Capacity: 931 Series heaters are available as single

or double modules with ratings up to 8,000 W and 320 CFM in 480 volt single-phase.

• Control Options: Heaters can be controlled by a building man-agement system with the addition of a low voltage relay.

• Flexible Mounting: Units can be surface, (with optional surface mounting box) recessed or installed in T-Bar ceiling systems.

Applications• Entryways

• Garages

• Hallways

• Restrooms

• Stairwells

• Vestibules

Heating Elements – Steel finned tubular elements.

Outlet Grille – The louvered front grille is made of 18-gauge steel with rounded corners. The grille is finished with a polyester powder paint in white or almond.

Built-in Controls – Automatic reset thermal cutout, fan override with contactor when required.

Fan Motor – Permanently lubricated, open and ventilated fan. The single unit has a 160 CFM fan (55.5 dBA) and the double unit has 2 x 160 CFM fans (58.5 dBA).

Installation Requirements – For best performance, do not install ceiling heaters above recommended maximum mounting height of ten feet. Heater must be installed at least ten inches from adjacent walls.Rough In Dimensions – • 1500/1125 - 4800 Watt heaters: 14-1/2” wide x 19-7/8” high

x 4-1/2” deep. • 6000/4500 - 8000 Watt heaters: 30-3/16” wide x 19-7/8” high

x 4-1/2” deep.

Factory Built-in Options Field-Installed Options (shipped loose for field installation into heater)

Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Remote Room Thermostat – See page

Code Description

D1 Disconnect Switch 600V, Three-pole, 32 Amp

D2 Disconnect Switch, 600V, Three-pole, 64 Amp

D3 Disconnect Switch 277V, Double-pole, 16 Amp

R1 24V Control Relay

R2 24V Control Relay with Transformer (1)

T1 Built-in Tamperproof Thermostat

T2 Adjustable Thermostat

CatalogNumber Description

931-124506 Surface Mounting Box (1500-4800W)931-158213 Surface Mounting Box (6000-8000W)

931-124507 Built-in Thermostat Kit (both knob & tamperproof plug provided)

931-124508 24V Control Relay Kit931-124512 T-Bar Adapter 23-3/4” x 23-3/4” (1500-4800W)931-124513 T-Bar Adapter 23-3/4” x 47-11/16” (6000-8000W)931-218272 Extruded Aluminum Front Grille (1500-4800W)931-218273 Extruded Aluminum Front Grille (6000-8000W)

931-218274 Surface Mounting Box for Aluminum Front Grille (1500-4800W)

931-218275 Surface Mounting Box for Aluminum Front Grille (6000-8000W)

931 SeriesCommercial Ceiling Heater

Standard Construction Features

Standard Special Colors

(1) Not available for 120V heaters.

Page 72: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

71

931 SeriesCommercial Ceiling Heater

Heater Listing

(1) Total Amps includes motor amps.Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Watts Volts(1 Phase)

TotalsAmps (1) CFM

ApproximateAir Temperature

Rise 0F (0C)

Weightlb (kg)

CatalogNumber

1500/1125 240/208 6.6/5.8 160 30/27 (17/12) 20 (9) HX-931U01500V

1500120 12.9 160 30/27 (17/12) 20 (9) HX-931U01500B277 5.8 160 30 (17) 26 (12) HX-931U01500N480 3.5 160 30 (17) 26 (12) HX-931U01500T

2000/1500 240/208 8.7/7.6 160 40/30 (22/17) 20 (9) HX-931U02000V

2000277 7.6 160 40 (22) 26 (12) HX-931U02000N480 4.5 160 40 (22) 26 (12) HX-931U02000T

3000/2250 240/208 12.9/11.2 160 60/45 (33/25) 20 (9) HX-931U03000V

3000277 11.2 160 60 (33) 26 (12) HX-931U03000N480 6.6 160 60 (33) 26 (12) HX-931U03000T

4000/3000 240/208 17.0/14.8 160 80/60 (44/33) 20 (9) HX-931U04000V

4000208 19.6 160 80 (44) 20 (9) HX-931U04000C277 14.8 160 80 (44) 26 (12) HX-931U04000N480 8.7 160 80 (44) 26 (12) HX-931U04000T

4800/3600 240/208 20.5/17.8 160 95/83 (53/36) 24 (11) HX-931U04800V

4800208 23.6 160 95 (53) 24 (11) HX-931U04800C277 17.8 160 95 (53) 26 (12) HX-931U04800N480 10.4 160 95 (53) 26 (12) HX-931U04800T-

6000/4500 240/208 25.4/22.0 320 60/45 (33/25) 40 (18) HX-931U06000V

6000277 22.1 320 60 (33) 52 (24) HX-931U06000N480 12.9 320 60 (33) 52 (24) HX-931U06000T

8000/6000 240/208 33.7/29.2 320 80/60 (44/33) 40 (18) HX-931U08000V

8000208 38.9 320 80 (44) 40 (18) HX-931U08000C277 29.3 320 80 (44) 52 (24) HX-931U08000N480 17.1 320 80 (44) 52 (24) HX-931U08000T

KOE Ø22 mmKOE Ø7/8"

KOE Ø22 mmKOE Ø7/8"

368 mm14 7/16" 51 mm

2"

212 mm8 5/16"

74 mm2 7/8" 55 mm

2 3/16"

34 mm1 5/16"

506 mm19 7/8"

34 mm1 5/16"

51 mm2"

51 mm2"

Installation (All Models)Side View (All Models)

Surface

Recessed

Front View Front ViewSide View

Top ViewTop View

Single Unit

410 mm16 1/8"

810 mm31 7/8"

767 mm30 3/16"

561 mm22 1/16"

33 mm1 5/16"

Double Unit

109 mm4 5/16"

109 mm4 5/16"

561 mm22 1/16"

Required CeilingDepth Opening

1500/1125-4800Watt Heaters

6000/4500-8000Watt Heaters

Page 73: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

72

941 SeriesForced-Air Ceiling Heater

Applications• Breezeways

• Entryways

• Restrooms

• Small Offices

• Storage Rooms

The 941 Series ceiling heater is designed for recessed mounting into a ceiling. It provides heat in a quiet, efficient manner. Single units can heat small areas and multiple heaters can be used in large or odd-shaped rooms.

• Mounting Options: Units can be surface (with optional box) or recessed mounted. A tapered recess box assures a tight fit when mounted into the wall.

Standard Construction FeaturesHousing – The cabinet is 20-gauge steel with a V-shaped re-cessed box.Outlet Grille – The louvered front grille is made from 22-gauge steel with rounded corners. The grille is finished with an epoxy/ polyester powder paint in white or almond. Optional colors: metallic silver, bronze, metallic charcoal, aluminum, and semi-gloss.Built-in Controls – Automatic reset thermal cutout. Fan Motor – Quiet, permanently lubricated axial fan operates at 38 dBA at 40 CFM for models up to 1,000 W and 41.3 dBA at 80 CFM for all models rated above 1,000 W.

Installation Requirements – The air outlet should be installed a minimum of ten inches from the wall and should be oriented towards the center of the room.Control – Room temperature is controlled by a remote wall mounted thermostat which is sold separately.Rough In Dimensions – All heaters: 7-3/16” wide x 14-1/8” high x 3” deep.

Standard Special Colors

Pictures showing front panel. Directional vane air flow.

Mounting positions available. Pictures showing front panel. Directional vane air flow.

1 2 3 4

OVS OVSP

Page 74: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

73

941 SeriesForced-Air Ceiling Heater

(1) Total Amps = Heating element amps and motor amps.All models listed are single-phase.Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Watts Volts(1 Phase)

TotalAmps (1) CFM

Approximate AirTemperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

500 120 4.6 40 40 (22) 9 (4) HX-941U00500B

500/375 240/208 2.3/2.0 40 40/30 (22/17) 9 (4) HX-941U00500V

750 120 6.7 40 60 (33) 9 (4) HX-941U00750B

750/563 240/208 3.3/2.9 40 60/45 (33/25) 9 (4) HX-941U00750V

1000 120 8.7 40 80 (44) 9 (4) HX-941U01000B

1000/750 240/208 4.5/3.8 40 80/60 (44/33) 9 (4) HX-941U01000V

1250 120 10.8 80 50 (28) 9 (4) HX-941U01250B

1250/938 240/208 5.4/4.7 80 50/37 (28/21) 9 (4) HX-941U01250V

1500 120 12.9 80 60 (33) 9 (4) HX-941U01500B

1500/1125 240/208 6.5/5.6 80 60/45 (33/25) 9 (4) HX-941U01500V

Heater Listing

Factory Built-in Options

Field-Installed Options (shipped loose for field installation into heater)

Standard colors - Add W for white finish or A for almond finish to the end of catalog number.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Remote Room Thermostat – See pages 111-112.

Code Description

D3 Disconnect Switch 277V, Double-pole, 16 Amp

C Factory Sealed Elements for high humidity applications

CatalogNumber Description

941-227578 Surface Mounting Box

Page 75: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

74

938 SeriesFan-Forced Toe-Space Heater

The 938 Series heater is designed for installation in places where other heaters do not fit. These heaters can be installed into the toe space or kick space below a cabinet, in the soffit above a cabinet or into risers of a stairway. • Multiple Wattage: Quick disconnect lead wires allow output

conversion from 1,000 to 500 watts. • Overtemperature Protection: Automatic reset thermal cutout is

provided for primary overtemperature protection. More convenient than thermal fuses, which require field replacement when overtem-perature conditions occur.

• Two-piece Construction: Unit is designed for easy installation. The fan, motor and controls are factory assembled into a sheet metal box with a removable front grille.

Applications• Checkout Counters• Kitchens

• Reception Areas• Ticket/Tollbooths

Standard Construction FeaturesHeating Elements – Steel finned tubular elements provide durability.

Outlet Grille – Heavy 20-gauge steel grille has a polyester powder paint finish. Standard grille colors include black, white or almond.

Built-in Controls – Heater comes complete with a bi-metal auto-matic and manual reset thermal cutouts and warning light to indicate when the heater is running excessively hot.

Fan Motor – Factory-lubricated fan motor operates at 44.5 dBA with 80 CFM.

Soffit Adapter – Included with the heater.

Installation Requirements – Do not install heater near thermosensitive materials.

Rough In Dimensions – All heaters: 20-1/2” wide x 3-27/32” high x 10-1/2” deep.

Factory Built-in Options

Heater Listing

Code DescriptionT5 Adjustable thermostat, single-pole; 25 Amp

T6 Adjustable thermostat, double-pole; 25 Amp with off position

CatalogNumber Description

938-158480 Adjustable thermostat kit, single-pole; 25 Amp

938-218240 Adjustable thermostat kit, double-pole; 25 Amp with off position

Watts Volts TotalAmps (1) CFM

ApproximateAir Temperature

Rise 0F (0C)

Weightlb (kg)

CatalogNumber

1000/500 120 8.8/4.6 80 20 (11) 13 (6) HX-938U01000B500/375

240/2082.5/2.3 80 20/15 13 (6)

HX-938U01000V1000/750 4.6/4.1 80 40/30 (22/17) 13 (6)

515 mm20 1/4"

102 mm4"

553 mm21 3/4"

257 mm10 1/8"

102 mm4" max.

98 mm3 27/32"

520 mm20 1/2"

267 mm10 1/2"

93 mm3 11/16"

MountingUnder Cabinet

Ceiling

Floor

Wall Opening

Mountingon Cabinet

Front ViewSide View

Top View

Field-Installed Options (shipped loose for field installation into heater)

Remote Room Thermostat – See pages 111-112.

(1) Total Amps = Heating element amps and motor amps.Add W to end of catalog number for white finish, A for almond, or BK for black.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

Standard Special Colors

Page 76: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

75

939 SeriesFan-Forced Floor Heater

Heater Listing

(1) Total Amps = Heating element amps and motor amps.Add W to end of catalog number for white finish, A for almond, or BZ for bronze.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

The 939 Series floor heater is compact to fit into tight spaces. It is designed to mount between the floor joists.• Unique Design: The heater features a separate housing and core

assembly. The core assembly is completely prewired with leads and an electrical connection plug, which can be removed for ser-vice and cleaning without disturbing the housing or field wiring.

• Safety Screen: A protective screen prevents foreign objects from falling onto the heating elements or interfering with the fan.Applications

• Entryways

• Open Stairwells

• Small Rooms

• Under Large Window Areas

Standard Construction FeaturesHeating Elements – Steel finned tubular elements provide durability.

Housing – Heavy welded 20-gauge steel housing.

Outlet Grille – The 14-gauge steel grille has a polyester pow-der paint finish. Standard grille colors include bronze, white or almond.

Built-in Controls – Manual reset thermal cutout prevents over-heating.

Fan Motor – Quiet, factory-lubricated fan motor operates at 43.9 dBA with 80 CFM.

Installation Requirements – Floor heaters should be installed a minimum of six inches from adjacent walls.

Rough In Dimensions – All heaters: 14-3/8” wide x 7-7/16” high x 8” deep.

Remote Room Thermostat – See pages 111-112.

Watts Volts TotalAmps (1) CFM

Approximate AirTemperature Rise

°F (°C)

Weightlb (kg)

CatalogNumber

500 120 4.6 80 20 (11) 16 (7.3) HX-939U00500B

1000 120 8.8 80 40 (22) 16 (7.3) HX-939U01000B

1500 120 13.0 80 60 (33) 16 (7.3) HX-939U01500B

500/375 240/208 2.6/2.3 80 20/15 (11/8.3) 16 (7.3) HX-939U00500V

1000/750 240/208 4.6/4.1 80 40/30 (22/17) 16 (7.3) HX-939U01000V

1500/1125 240/208 6.7/5.9 80 60/45 (33/25) 16 (7.3) HX-939U01500V

203 mm8"

362 mm14 1/4"

403 mm15 7/8"

224 mm8 13/16"

184 mm7 1/4"

Standard Special Colors

Page 77: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

76

AS SeriesRadiant Ceiling Panels

AS Series radiant panels are ideal for offsetting heat loss through exterior glass on the perimeter of a building. They help to control the problem of condensation typically found with these large exterior glass walls. Radiant panels pro-vide improved comfort by maintaining an even temperature from floor to ceiling.• Radiant Heat: Radiant energy travels in straight lines and

is absorbed by objects in the room, warming the space. Air quality is maintained because no forced air movement occurs with radiant heating.

• Maximize Work Area: Ceiling mounted panels permit full use of floor and wall space.

• Maintenance Free: Radiant panels have no moving parts, so they are maintenance free and can provide years of quiet, safe and clean operation.

Applications• Atriums

• Enclosed Walkways

• Entryways

• Hospitals

• Lobbies

• Offices

• Schools

• Warehouses

Standard Construction FeaturesHeating Element – High quality alloy resistance wire is electri-cally insulated with a UL Listed TEFZEL® compound rated for 200°C (392°F). Heating wires are covered with high-efficiency reflective foil.

Panel Design – Panel is made of 22-gauge galvanized steel with a white baked-on powder paint finish. Panel is crimped, not riveted, for improved strength.

Insulation – Each panel contains two inches of high tempera-ture/high density mineral wool insulation.

Electrical – A junction box is attached to each panel for field wiring and to connect panels to each other.

Installation Requirements – Heater can be installed in sus-pended T-bar ceiling systems or can be surface or recessed mounted using optional mounting frames.

Heater comes equipped with four suspension clips. Connecting wire or chain is supplied by customer.

Minimum recommended mounting height is eight feet from the floor.Rough In Dimensions – Plaster Mounting Frames:• PF-22: 24-1/8” x 24-1/8”• PF-24 and SPF 24: 24-1/8” x 48-1/8”• PF-1448: 14-18” x 48-1/8”• PF-1460: 14-1/8” x 60-1/8”

Page 78: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

77

AS SeriesRadiant Ceiling Panels

Factory Built-in Options

Finishes

Field-Installed Options (shipped loose for field installation into heater)

(1) Stainless steel frame, specify 304 or 316 type. Add finish code to end of catalog number.

Remote Room Thermostat – See pages 111-112.

Control OptionsCatalog Number Description

SR-LV

SmartRooms low voltage controller. Sensor(s) must be ordered at the same time. Requires connection to SmartRooms Communication Panel.

PL-1 Plaster ring for SR-LV Controller

SensorsUsed with SR-240/120, 15’ long

Longer length add per foot

SRDP-10/10 SmartRooms Panel w/10comm. Ports and 10 ea. 20 amp relays

SRDP-10/20 SmartRooms Panel w/10comm. Ports and 20 ea. 20 amp relays

SRDP-20/20 SmartRooms Panel w/20comm. Ports and 20 ea. 20 amp relays

Code Description

FC 48” Flexible conduit

S Silicone seams, provides protection in high moisture areas. Includes 36” of sealtite conduit.

TEG Tegular reveal edge detail of 15/16” grid.

TEGF Fineline Tegular reveal edge for 9/16” grid.

Code Description

O Specify custom color finish.

PT Standard finish; textured white baked-on powder coating on front panel.

S304 304 Stainless steel construction, includes 36” of sealtite conduit and silicone seal.

S316 316 Stainless steel construction, includes 36” of sealtite conduit and silicone seal.

SSSilk screen to match acoustical ceiling tiles (specify style).

One time set-up fee if pattern is not in stock.

CatalogNumber

WidthIn. (mm)

LengthIn. (mm)

Weightlb. (kg)

Surface Mounting Frames

SF-22 24 (610) 24 (610) 4 (1.8)

SF-24 24 (610) 48 (1219) 9 (4.1)

SF-1448 14 (356) 48 (1219) 8 (3.6)

SF-1460 14 (356) 60 (1524) 10 (4.5)

Plaster Mounting Frames

PF-22 24 (610) 24 (610) 2 (1.0)

PF-24 24 (610) 48 (1219) 4 (1.8)

SPF-24 (1) 24 (610) 48 (1219) 4 (1.8)

PF-1448 14 (356) 48 (1219) 5 (2.3)

PF-1460 14 (356) 60 (1524) 6 (2.7)

Filler Panel

FP Sized and finished to match standard, custom color or silk screened panel.

Page 79: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

78

AS SeriesRadiant Ceiling Panels Wire Suspended

Flush Mounting Kit

NailCeiling Joist

Flush M ount Fram ein Drywall Ceiling

Flush Mount Framein Drywall Ceiling

Ceiling Joist

Nail

Cutaway View of AS Series Heater

Reflective Foil

4” x 4” x 1-1/2”Junction BoxWith Cover

High DensityHeating Panel

Support Clips

2”, 4 Lb DensityHigh Temperature MineralWool Insulation

22 Gauge Galvanized Steel Front and Back of Unit

Factory Finishedwith a High Temperature, Textured Powder Paint Finish

Electric Heating Element - Alloy

Wire, Tefzel Insulation

2”

2"

1-1/2"2"

Radiant Heater

Junction Box4" x 4" 1-1/2"

Ceiling Joist

Nail

Flush Mounting FrameFactory Painted 24 GaugeExtruded Aluminum

Finished Ceiling

Each Kit Includes:2 - Side Pieces2 - End Pieces4 - Corner Brackets

Plaster FrameFlush Mount KitPlaster FrameFlush Mount Kit

Ceiling Joist

Radiant Heater

Junction Box4” x 4” x 1-1/2”

Each Kit Includes:2 - Side Pieces2 - End Pieces4 - Corner Brackets

Flush Mounting FrameFactory Painted 24 GaugeExtruded Aluminum

Nail

2”1-1/2”

Ceiling

Ceiling Joist

Radiant Heater

Power Supply

4” x 4” x 1-1/2” Junction Box

2”4”

Each Kit Includes:2 - Side Channels2 - End Channels4 - Corner Brackets with screws

Toggle Bolt

Corner MountingBracket with ScrewsSurface Mounting Frame

Factory Painted 12 GageGalvanized Steel

HeightWidth

Finished Ceiling

2”

Surface Mounting

Page 80: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

79

AS SeriesRadiant Ceiling Panels

Add finish code to end of catalog number. See page 33.

AS - Radiant Ceiling Panels ListingWatts Volts

(1 Phase)Width

In. (mm)Height

In. (mm) Amps WeightLb. (kg)

CatalogNumber

24 x 24250 120 24 (610) 24 (610) 2.1 15 (6.8) HX-AS2424-250-120250 240 24 (610) 24 (610) 1.0 15 (6.8) HX-AS2424-250-240250 277 24 (610) 24 (610) 0.9 15 (6.8) HX-AS2424-250-277310 120 24 (610) 24 (610) 2.6 15 (6.8) HX-AS2424-310-120310 208 24 (610) 24 (610) 1.5 15 (6.8) HX-AS2424-310-208310 240 24 (610) 24 (610) 1.3 15 (6.8) HX-AS2424-310-240310 277 24 (610) 24 (610) 1.1 15 (6.8) HX-AS2424-310-277325 240 24 (610) 24 (610) 1.4 15 (6.8) HX-AS2424-325-240335 120 24 (610) 24 (610) 2.8 15 (6.8) HX-AS2424-335-120335 277 24 (610) 24 (610) 1.2 15 (6.8) HX-AS2424-335-277375 120 24 (610) 24 (610) 3.1 15 (6.8) HX-AS2424-375-120375 208 24 (610) 24 (610) 1.8 15 (6.8) HX-AS2424-375-208375 277 24 (610) 24 (610) 1.4 15 (6.8) HX-AS2424-375-277

24 x 48500 120 24 (610) 48 (1219) 4.2 30 (13.6) HX-AS2448-500-120500 240 24 (610) 48 (1219) 2.1 30 (13.6) HX-AS2448-500-240500 277 24 (610) 48 (1219) 1.8 30 (13.6) HX-AS2448-500-277515 208 24 (610) 48 (1219) 2.5 30 (13.6) HX-AS2448-515-208535 208 24 (610) 48 (1219) 2.6 30 (13.6) HX-AS2448-535-208625 120 24 (610) 48 (1219) 5.2 30 (13.6) HX-AS2448-625-120625 208 24 (610) 48 (1219) 3.0 30 (13.6) HX-AS2448-625-208625 240 24 (610) 48 (1219) 2.6 30 (13.6) HX-AS2448-625-240660 277 24 (610) 48 (1219) 2.4 30 (13.6) HX-AS2448-660-277725 240 24 (610) 48 (1219) 3.0 30 (13.6) HX-AS2448-725-240750 120 24 (610) 48 (1219) 6.3 30 (13.6) HX-AS2448-750-120750 208 24 (610) 48 (1219) 3.6 30 (13.6) HX-AS2448-750-208750 277 24 (610) 48 (1219) 6.3 30 (13.6) HX-AS2448-750-277

14 x 48300 240 14 (356) 48 (1219) 1.3 18 (8.2) HX-AS1448-300-240350 120 14 (356) 48 (1219) 2.9 18 (8.2) HX-AS1448-350-120350 277 14 (356) 48 (1219) 1.3 18 (8.2) HX-AS1448-350-277400 208 14 (356) 48 (1219) 1.9 18 (8.2) HX-AS1448-400-208435 208 14 (356) 48 (1219) 2.1 18 (8.2) HX-AS1448-435-208435 240 14 (356) 48 (1219) 1.8 18 (8.2) HX-AS1448-435-240435 277 14 (356) 48 (1219) 1.6 18 (8.2) HX-AS1448-435-277

14 x 60350 120 14 (356) 60 (1524) 2.9 22 (10.0) HX-AS1460-350-120375 240 14 (356) 60 (1524) 1.6 22 (10.0) HX-AS1460-375-240375 277 14 (356) 60 (1524) 1.4 22 (10.0) HX-AS1460-375-277450 208 14 (356) 60 (1524) 2.2 22 (10.0) HX-AS1460-450-208535 277 14 (356) 60 (1524) 1.9 22 (10.0) HX-AS1460-535-277550 240 14 (356) 60 (1524) 2.3 22 (10.0) HX-AS1460-550-240

Page 81: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

80

918 Series Radiant Heater

918 Series heaters are designed to supply efficient radiant heat. They provide greater comfort at lower temperature settings and can be set up for individual or zone control to reduce energy costs. • Radiant Heat: Radiant energy travels in a straight line from

the heater to people and objects in the room, warming the space.

• Convection Flow: The design of the heater provides a convection flow from behind and over the top of the unit to circulate warm air into the room.

• Virtually Maintenance Free: No moving parts to replace or service.

• Wall Installation: For ease of installation, brackets are supplied that do not require the opening of the heater’s casing.

Applications• Classrooms

• Garages

• Hospital Rooms

• Lobbies

• Offices

• Restrooms

Standard Construction FeaturesHeating Element – Stainless steel tubular heating element.

Housing – Heater has an 18-gauge G-90 galvanized steel frame. Front panel shall be extruded heavy gauge aluminum.

Front Panel – Heater shall be provided with a silichem off-white, matt black, or anodized aluminum finish chosen for radiant heat-ing applications. Additional colors are available to blend in with the decor.

Electrical – Junction boxes with 4” (102mm) ground wires are provided on both ends. Two 7/8” (22mm) knockouts are pro-vided on the back of the heater for ease of wiring. A wireway is provided that is approved for interconnection of units for wall-to-wall applications.

Installation Requirements – Minimum clearances: 6’ (1.83m) from the floor; and 4-1/2” (114mm) from ceiling. A variety of accessories are available for wall-to-wall installations.

Remote Room Thermostat – See pages 111-112.

114 mm4-1/2”

SideView

TopView

RearView

79 mm3-1/8”

47 mm1-7/8”

180 mm7-1/16”

107 mm4-1/4”

39 mm1-1/2”

864 mm to 2870 mm34” to 113”

Wall

Ceiling

Page 82: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

81

918 Series Radiant Heater

Cove Heater Listing

Watts Volts(1 Phase) Amps Length

In. (mm)Weightlb (kg)

CatalogNumber

450

120 3.7 34 (864) 6 (2.7) HX-918U00450B

208 2.2 34 (864) 6 (2.7) HX-918U00450C

240 1.9 34 (864) 6 (2.7) HX-918U00450J

277 1.6 34 (864) 6 (2.7) HX-918U00450N

600

120 5 47 (1194) 8 (3.6) HX-918U00600B

208 2.9 47 (1194) 8 (3.6) HX-918U00600C

240 2.5 47 (1194) 8 (3.6) HX-918U00600J

277 2.2 47 (1194) 8 (3.6) HX-918U00600N

750

120 6.2 59 (1499) 10 (4.5) HX-918U00750B

208 3.6 59 (1499) 10 (4.5) HX-918U00750C

240 3.1 59 (1499) 10 (4.5) HX-918U00750J

277 2.7 59 (1499) 10 (4.5) HX-918U00750N

900

120 7.5 71 (1803) 12 (5.4) HX-918U00900B

208 1.3 71 (1803) 12 (5.4) HX-918U00900C

240 3.7 71 (1803) 12 (5.4) HX-918U00900J

277 3.2 71 (1803) 12 (5.4) HX-918U00900N

1050

120 8.8 83 (2108) 13 (5.9) HX-918U01050B

208 5 83 (2108) 13 (5.9) HX-918U01050C

240 4.4 83 (2108) 13 (5.9) HX-918U01050J

277 3.8 83 (2108) 13 (5.9) HX-918U01050N

1200

120 10 94 (2388) 15 (6.8) HX-918U01200B

208 5.8 94 (2388) 15 (6.8) HX-918U01200C

240 5 94 (2388) 15 (6.8) HX-918U01200J

277 4.3 94 (2388) 15 (6.8) HX-918U01200N

1500

120 12.5 113 (2870) 18 (8.2) HX-918U01500B

208 7.2 113 (2870) 18 (8.2) HX-918U01500C

240 6.3 113 (2870) 18 (8.2) HX-918U01500J

277 5.4 113 (2870) 18 (8.2) HX-918U01500N(All models listed are single-phase)Standard colors - Add BL for silichem off-white, NM for mat black, and AA for anodized aluminum finish at the end of catalog number.

Factory Built-in Options

Code Description

T5 Adjustable Thermostat, Single-pole

T6 Adjustable Thermstat, Double-pole with off position, factory installed into an additional 4” section

Field-Installed Options (shipped loose for field installation into heater)

¶ Standard colors - Add BL for silichem off-white, NM for mat black, and AA for anodized aluminum finish at the end of catalog number.

CatalogNumber Description

918-276918 Splice plate

918-276919 Adjustable Thermostat Kit, Single-pole

918-276920 Adjustable Thermostat Kit, Double-pole with off position, mounted in a 4” section

Page 83: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

82

How to Order

HX - 9XX U 1500 B W -XX - D3

Series

Wattage

Options

ListingU = CSAusC = CSA

CUI MountingConfigurations

Voltage Code

B 120/1C 208/1D 208/3J 240/1K 240/3N 277/1P 240/208/3T 480/1U 480/3V 240/208/1

Color

A = AlmondW = WhiteBZ = BronzeBK = Semi-Gloss BlackAE = Metallic SilverCM = Metallic CharcoalAL = AluminumO = Other (specify)

Page 84: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

83

Comparison ChartBaseboard and Convector Heaters

Features Baseboard903

ArchitecturalSill-HeightConvector904/906

IndustrialSill-HeightConvector905/907

High-EndBaseboard

Heater910

ArchitecturalConvector908/909

Mini Draft Barrier

914

High Watt Density Draft

Barrier916

Architectural Cabinet

Convector911/912

TypicalApplications

Retail stores,Small offices

Commercial buildings,

Public buildings

Industrialbuildings,

Institutions

Office buildingCommercial

building

Banks, OfficesClassrooms,Conference

rooms

Entryways, Hallways, Schools

EntrywaysHllways,Shopping centers

Classrooms,Conference

rooms, Hallways

Wattage Range 300 to 2,500 200 to 2,500 200 to 2,500 100 to 200 800 to 4,000 300 to 1,400 375 to 4,000 1,000 to 6,000

Watt Density W/ft (W/m)

275 (900)200 (650)

275 (900)200 (650)150 (490)100 (330)

275 (900)200 (650)150 (490)100 (330)

200 (650)275 (900)

500 (1640)375 (1250)

175 (574)150 (490)

500 (1,640)355 (1,165)250 (820)175 (575)

1,000 (3,280)750 (2,450)500 (1,640)

Voltages 120 - 277(1 Ph)

120 - 277(1 Ph)

120 - 277(1 Ph)

120V - 480V(1 ph)

208 - 277(1 Ph)

208 - 480(1 Ph)

208 - 480(1 Ph)

208 - 277 (1 Ph)

208 - 480 (3 Ph)

Element Type

Stainlesssteel with

aluminum fins

Stainless steel with

aluminum fins

Stainless steel with

aluminum fins

Stainless steel with

aluminum fins

Stainless steel with

aluminum fins

Stainlesssteel with

aluminum fins

Stainlesssteel with

aluminum fins

Stainlesssteel with

aluminum fins

Standard Construction

22-gauge steel body and front

panel

18-gauge steel cabinetry with 14-gauge alu-minum front

cover

18-gauge steel cabinetry with 16-gauge steel

front cover

20-gauge steel cabinetry, with

14-gauge aluminum

cover

20-gauge steel cabinetry,

16-gauge steel front cover

and extrudedaluminum

grille

18-gauge steel cabinetry

with 14-gauge aluminum

front and top covers

18-gauge steel cabinetry

with 14-gauge aluminum

front and top covers

20-gauge steel cabinetry with 16-gauge steel

front cover

FinishEpoxy/Poly-

ester powder paint

Epoxy/Poly-ester powder

paint

Epoxy/Poly-ester powder

paint

Epoxy/Poly-ester powder

paint

Epoxy/Poly-ester powder

paint

Epoxy/Poly-ester powder

paint

Epoxy/Poly-ester powder

paint

Epoxy/Poly-ester powder

paint

Sloped-Top Version No 904 905 No 908 No No 911

Bottom Air Inlet Option No Yes Yes No No Standard Standard No

Pedestal Kit Option No Yes Yes No Yes Yes Yes Yes

Front WarmAir Outlet

OptionNo No No No Yes

(BAI only) No No Yes (CAI Only)

Custom Colors Yes Yes Yes Yes Yes Yes Yes Yes

AgencyApprovals CSAUS CSAUS CSAUS CSAUS CSAUS CSAUS CSAUS CSAUS

914

905

916911

903906910

909

Page 85: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

84

The 903 Series baseboard heater is more compact than any other heater on the market, yet it provides a high level of performance and strength. The unit’s trim design enhances its appearance and rounded corners eliminate the sharp edges found on square heaters.• Easy to Install: Heaters may be mounted flush on any floor surface.

Two rows of oblong mounting holes with center mark for ease of installation. No disassembly installation with single-screw built-in rear entry wire holder.

• Electric Receptacles: Units can be furnished with built-on 120 and 240-volt receptacles to provide access for other electrical appliances.

• Control Options: Heaters can be controlled by a building manage-ment system with the addition of a low voltage relay. Adding a pro-portional control device provides precise temperature control and increased energy savings.

Applications• Offices

• Retail Stores

• Restrooms

• Restaurants

Standard Construction FeaturesHeating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation.

Housing – Robust 22-gauge steel body with 20-gauge front panel and welded junction box, with 4H pencil hardness epoxy/polyester powder paint finish in white or almond.

Built-in Controls – Linear limit, automatic reset thermal cutout.

903 Series Baseboard Heater

Standard Special Colors

Page 86: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

85

903 Series Baseboard Heater

Field-Installed Options (shipped loose for field installation into heater)

Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.

Factory Built-in Options

Code Description

D3 Disconnect Switch, 277V, Double-pole, 16 Amp

D1 Disconnect Switch, 600V, Three-pole, 40 Amp

M1 High Altitude Automatic Cutout

R1 24V Relay, Single-pole, 240V, 22 Amp: 277V, 19 Amp

R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp

R7 Triac Proportional Relay, 277V Max, 2500 W Max.

T1 Tamperproof Thermostat, Single-pole, 277V, 25 Amp

T2 Tamperproof Thermostat, Double-pole, 277V, 25 Amp

T3 Adjustable Thermostat, Single-pole, 277V, 17 Amp

T4 Adjustable Thermostat, Double-pole, 277V, 17 Amp

T5 Adjustable Thermostat, Single-pole, 600V, 25 Amp

T6 Adjustable Thermostat, Double-pole, 600V, 25 Amp

W1 Wireless thermostat and relay module for heaters, factory installed at left end

W2 Wireless thermostat and relay module for heaters, factory installed at right end

W3 Wireless relay module for heater, factory installed at left end

W4 Wireless relay module for heaters, factory installed at right end

Catalog Number Description

903-243496‡Baseboard Section 6 in. (152 mm) - 240V Splitter Box to permanently connect an air conditioner (20A switch, double-pole, double-throw)

903-243497‡Baseboard Section 6” (152mm) - 240V Splitter Box toward a surface mount, 6-20R Receptacle (20A switch, double-pole, double-throw

903-243498‡Baseboard Section 6” (152mm) - Surface mounted duplex 5-15R receptable, 120V, 15A

903-243499‡Baseboard Section 6” (152mm) - Surface mounted duplex 6-20R receptable, 240V, 15A

903-243500‡Baseboard Section 6” (152mm) - for the installa-tion of a 24V relay (relay not included)

903-243501 Electronic Relay Kit, single-pole, coil 24V, with transformer, 15A 277 max

903-243502 Electronic Relay Kit, single-pole, coil 24V, without transformer, 15A 277 max

903-243503 Relay Kit 24V with transformer, 120V, 25 Amp (2-wire only)

903-243504 Relay Kit 24V with Transformer, 208V, 22 Amp

903-243505 Relay Kit 24V with Transformer, 240V, 22 Amp

903-243506 Relay Kit 24V with Transformer, 277V, 18 Amp

903-243507 Relay Kit 24V without Transformer, 120V - 240V, 22 Amp, 277, 18 Amps

903-243509‡ Thermostat Kit, Adjustable, Double-pole, 277V, 25 Amp with off position

903-243510‡ Thermostat Kit, Adjustable, Single-pole, 277V, 25 Amp

903-243511‡Thermostat Kit, Tamperproof, Double-pole, 277V, 25 Amp with off position

903-243512‡ Thermostat Kit, Tamperproof, Single-pole, 277V, 25 Amp

903-243513‡ Touch Up Brush Paint (1/2 oz)

903-243515‡ Universal Corners (inside and outside)

Remote Room Thermostat – See pages 111-112.

Page 87: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

86

Heater ListingHow to order: Heater Code with color code + Options (example HX-903U00750BW-T5)

Standard Watt Density Models 275 W/ft. (900 W/m)

Other single-phase voltages available, consult factory.‡Standard colors - Add W for white finish or A for almond finish to the catalog number when ‡ is indicated.Special or custom colors - See inside back cover for color codes to be added to the catalog number where ‡ is indicated.(*) These items must be ordered in pairs to reduce shipping damage.

LengthIn. (mm) Watts

Heater CodeWatts at

240/208V

Heater CodeWeight Lbs (kg)120V

(1 Ph) Amps 208V (1 Ph) Amps 277V

(1 Ph) Amps 277/240V (1 Ph) Amps

22.75(577) 300 HX-903U00300B‡ 2.5 HX-903U00300C‡ 1.4 — 1.1 300/225 HX-903U00300V‡ 1.3/1.1 4.5

(2.0)

27.75(702) 500 HX-903U00500B‡ 4.2 HX-903U00500C‡ 2.4 HX-903U00500N‡ 1.8 500/375 HX-903U00500V‡ 2.1/1.8 5.4

(2.4)

37.75(956) 750 HX-903U00750B‡ 6.3 HX-903U00750C‡ 3.6 HX-903U00750N‡ 2.7 750/563 HX-903U00750V‡ 3.1/2.7 7.0

(3.2)

48(1217) 1000 HX-903U01000B‡ 8.3 HX-903U01000C‡ 4.8 HX-903U01000N‡ 3.6 1000/750 HX-903U01000V‡ 4.2/3.6 8.7

(3.9)

60(1524) 1250 HX-903U01250B‡ 10.4 HX-903U01250C‡ 6.0 HX-903U01250N‡ 4.5 1250/938 HX-903U01250V‡ 5.2/4.5 10.7

(4.9)

72(1829) 1500 HX-903U01500B‡ 12.5 HX-903U01500C‡ 7.2 HX-903U01500N‡ 5.4 1500/1125 HX-903U01500V‡ 6.3/5.4 12.7

(5.7)

75.5(1916) 1750 — — HX-903U01750C‡ 8.4 HX-903U01750N‡ 6.3 1750/1313 HX-903U01750V‡ 7.3/6.3 13.2

(6.0)

96(2439) 2000 — — HX-903U02000C‡ 9.6 HX-903U02000N‡ 7.2 2000/1500 HX-903U02000V‡ 8.3/7.2 16.6

(7.5)

93(2364) *2250 — — HX-903U02250C‡ 10.8 HX-903U02250N‡ 8.1 *2250/1688 HX-903U02250V‡ 9.4/8.1 16.2

(7.3)

102.25(2596) *2500 — — HX-903U02500C‡ 12.0 HX-903U02500N‡ 9.0 *2500/1875 HX-903U02500V‡ 10.4/9.0 17.8

(8.0)

903 Series Baseboard Heater

Page 88: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

87

904 The 906/904 architectural sill-height convector (also known as draft barriers) are designed to fit under large windows to prevent cold down drafts. These heaters can provide total or supplemental heating for a variety of applications. • Installation Options: Units may be mounted to the wall flush

on the floor or on pedestals. Custom lengths, blank sections and inside or outside corners are available for wall-to-wall installa-tions. Units can be ordered with Option “S” for smooth painted finish when the back of the heater is visible.

• Added Safety: The sloped-top of the BCSI prevents objects from being set on top of the heater, which can restrict airflow and cause overheating.

• Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes including anodized aluminum are available.

Applications• Air, Rail or Bus Terminals

• Auditoriums

• Corridors

• Entryways

• Foyers

• Hallways

• Lobbies

• Offices

Standard Construction FeaturesHeating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet oper-ation.

Housing – Cabinet is constructed of 18-gauge steel with a 14-gauge aluminum front cover. The unit has an epoxy/poly-ester powder paint finish in white or almond. End caps are provided on all units.

Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. The outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof).

Built-in Controls – Linear limit, automatic reset thermal cut-out.

Electrical Connection – Each baseboard heater has a junction box located on both ends and a built-in full length wireway.

Installation Requirements – Field or factory-installed low voltage relay and thermostat kits fit into the right-hand junc-tion box only. Heaters 200 watt/ft or greater are not designed for residential use in the United States.

906

906/904 SeriesArchitectural Sill-Height ConvectorArchitectural Sloped Top Sill-Height Convector

Standard Special Colors

Page 89: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

88

906/904 SeriesArchitectural Sill-Height Convector

Architectural Sloped Top Sill-Height ConvectorField-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

Remote Room Thermostat – See pages 111-112.

Code Description

A Bottom Air InletD3 Disconnect Switch, 277V, Double-pole, 16 AmpL Custom Length

M1 High Altitude Automatic CutoutR1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 AmpR2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 AmpR6 Pneumatic Relay, 480V, 20 AmpR7 Triac Proportional Relay, 277V Max., 2500W Max.S Smooth painted finish on heater back

T1 Tamperproof Thermostat, Single-pole, 277V, 25 AmpT2 Tamperproof Thermostat, Double-pole, 277V, 25 Amp; with off positionT5 Adjustable Thermostat, Single-pole, 277V, 25 AmpT6 Adjustable Thermostat, Double-pole, 277V, 25 Amp; with off position

CatalogNumber Description

906-124585(1) Inside Corner906-124586(1) Outside Corner

906-124587 Round Pedestal Kit, 3-5”, Qty=2906-169806 Square Pedestal Kit, 2”, Qty=2

906-124588(1) Splice Plate 2” Long

906-124589(1) Contour Splice Plate for Code A (Bottom Air Inlet) and/or Heater with Pedestals

906-124590 24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp906-124591 24V Relay Kit with Transformer, 120V, 25 Amp (2-wire only)906-124592 24V Relay Kit with Transformer, 208V, 22 Amp906-124593 24V Relay Kit with Transformer, 240V, 22 Amp906-124594 24V Relay Kit with Transformer, 277V, 19 Amp906B-XXX(1) Blank Section (specify length in inches-XXX)906-224751 Tamperproof, Single-pole Thermostat Kit, 277V, 25 Amp

906-224752 Tamperproof, Double-pole Thermostat Kit, 277V, 25 Amp; with off position

906-224753 Single-pole Thermostat Kit, 277V, 25 Amp906-224754 Double-pole Thermostat Kit, 277V, 25 Amp; with off position

(1) Change 906 prefix to 904 for sloped top.Standard colors - Add W for white finish or A for alomond finish to the end of the part number.Special or custom colors - See inside back cover for color codes to be added to the end of part number.

6-1/8"

2-1/2"

1-7/8"

1-3/8"

15/16"

4"

3-7/8"

1-1/8"

1-1/8"2-3/8"

7/8"

2-3/8"

K.O. 7/8"

K.O. 1/4"

7-1/2"

2-1/2"

1-7/8"

1-3/8"

15/16"

4"

3-7/8"

1-1/8"

1-1/8"2-3/8"

7/8"

2-3/8"

K.O. 7/8"

K.O. 1/4"

904 Series

906 Series

Page 90: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

89

906/904 SeriesArchitectural Sill-Height ConvectorArchitectural Sloped Top Sill-Height Convector

Other voltages available. Consult factory.

‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.Special or custom colors - See inside back cover for color codes to be added to end of catalog number.

HX-906U (Flat Top)HX-904U (Sloped Top)How to order: Model + Heater Code with color code + Options (example HX-906U01000BW-2632-T5)

LengthIn.

(mm)

Density Watts

Heater CodeWatts at

240/208V

Heater Code Weight Lbs (kg)

W/Ft W/m 120V (1 Ph) Amps 208V

(1 Ph) Amps 277V (1 Ph) Amps 240/208V

(1 Ph) Amps 906(Flat)

904 (Sloped)

29(738)

100 330 200 00200B‡-738 1.7 00200C‡-738 1.0 — — 200/150 00200V‡-738 0.8/0.7

8.0(3.6)

9.1(4.1)

150 490 300 00300B‡-738 2.5 00300C‡-738 1.4 00300N‡-738 1.1 300/225 00300V‡-738 1.3/1.1

200 650 400 00400B‡-738 3.3 00400C‡-738 1.9 00400N‡-738 1.4 400/300 00400V‡-738 1.7/1.4275 900 500 00500B‡ 4.2 00500C‡ 2.4 00500N‡ 1.8 500/375 00500V‡ 2.1/1.8

39(992)

100 330 300 00300B‡-992 2.5 00300C‡-992 1.4 00300N‡-992 1.1 300/225 00300V‡-992 1.3/1.1

10.4(4.7)

11.9(5.4)

150 490 450 00450B‡-992 3.8 00450C‡-992 2.2 00450N‡-992 1.6 450/338 00450V‡-992 1.9/1.6

200 650 600 00600B‡-992 5.0 00600C‡-992 2.9 00600N‡-992 2.2 600/450 00600V‡-992 2.5/2.2275 900 750 00750B‡ 6.3 00750C‡ 3.6 00750N‡ 2.7 750/563 00750V‡ 3.1/2.7

49.3(1253)

100 330 400 00400B‡-1253 3.3 00400C‡-1253 1.9 00400N‡-1253 1.4 400/300 00400V‡-1253 1.7/1.4

12.8(5.8)

14.7(6.6)

150 490 600 00600B‡-1253 5.0 00600C‡-1253 2.9 00600N‡-1253 2.2 600/450 00600V‡-1253 2.5/2.2

200 650 800 00800B‡-1253 6.7 00800C‡-1253 3.8 00800N‡-1253 2.9 800/600 00800V‡-1253 3.3/2.9

275 900 1000 01000B‡ 8.3 01000C‡ 4.8 01000N‡ 3.6 1000/750 01000V‡ 4.2/3.6

58.8(1494)

100 330 500 00500B‡-1494 4.2 00500C‡-1494 2.4 00500N‡-1494 1.8 500/375 00500V‡-1494 2.1/1.8

15.1(6.8)

17.3(7.9)

150 490 750 00750B‡-1494 6.3 00750C‡-1494 3.6 00750N‡-1494 2.7 750/563 00750V‡-1494 3.1/2.7200 650 1000 01000B‡-1494 8.3 01000C‡-1494 4.8 01000N‡-1494 3.6 1000/750 01000V‡-1494 4.2/3.6

275 900 1250 01250B‡ 10.4 01250C‡ 6.0 01250N‡ 4.5 1250/938 01250V‡ 5.2/4.5

67.5(1715)

100 330 600 00600B‡-1715 5.0 00600C‡-1715 2.9 00600N‡-1715 2.2 600/450 00600V‡-1715 2.5/2.2

17.2(7.8)

19.7(9.0)

150 490 900 00900B‡-1715 7.5 00900C‡-1715 4.3 00900N‡-1715 3.2 900/675 00900V‡-1715 3.8/3.2200 650 1200 01200B‡-1715 10.0 01200C‡-1715 5.8 01200N‡-1715 4.3 1200/900 01200V‡-1715 5.0/4.3275 900 1500 01500B‡ 12.5 01500C‡ 7.2 01500N‡ 5.4 1500/1125 01500V‡ 6.3/5.4

76.9(1952)

100 330 700 00700B‡-1952 5.8 00700C‡-1952 3.4 00700N‡-1952 2.5 700/525 00700V‡-1952 2.9/2.5

19.4(8.8)

22.3(10.1)

150 490 1050 01050B‡-1952 8.8 01050C‡-1952 5.0 01050N‡-1952 3.8 1050/788 01050V‡-1952 4.3/3.8200 650 1400 01400B‡-1952 11.7 01400C‡-1952 6.7 01400N‡-1952 5.1 1400/1050 01400V‡-1952 5.8/5.0275 900 1750 — — 01750C‡ 8.4 01750N‡ 6.3 1750/1313 01750V‡ 7.3/6.3

85.6(2175)

100 330 800 00800B‡-2175 6.7 00800C‡-2175 3.8 00800N‡-2175 2.9 800/600 00800V‡-2175 3.3/2.9

21.5(9.7)

24.7(11.2)

150 490 1200 01200B‡-2175 10.0 01200C‡-2175 5.8 01200N‡-2175 4.3 1200/900 01200V‡-2175 5.0/4.3200 650 1600 — — 01600C‡-2175 7.7 01600N‡-2175 5.8 1600/1200 01600V‡-2175 6.7/5.8275 900 2000 — — 02000C‡ 9.6 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2

94.5(2400)

100 330 900 00900B‡-2400 7.5 00900C‡-2400 4.3 00900N‡-2400 3.2 900/675 00900V‡-2400 3.8/3.2

23.6(10.7)

27.2(12.3)

150 490 1350 — — 01350C‡-2400 6.5 01350N‡-2400 4.9 1350/1013 01350V‡-2400 5.6/4.9200 650 1800 — — 01800C‡-2400 8.7 01800N‡-2400 6.5 1800/1350 01800V‡-2400 7.5/6.5

275 900 2250 — — 02250C‡ 10.8 02250N‡ 8.1 2250/1688 02250V‡ 9.4/8.1

103.6(2632)

100 330 1000 01000B‡-2632 8.3 01000C‡-2632 4.8 01000N‡-2632 3.6 1000/750 01000V‡-2632 4.2/3.6

25.8(11.7)

29.7(13.5)

150 490 1500 — — 01500C‡-2632 7.2 01500N‡-2632 5.4 1500/1125 01500V‡-2632 6.3/5.4

200 650 2000 — — 02000C‡-2632 9.6 02000N‡-2632 7.2 2000/1500 02000V‡-2632 8.3/7.2

200 650 2250 — — 02250C‡-2632 10.8 02250N‡-2632 8.1 2250/1688 02250V‡-2632 9.4/8.1

275 900 2500 — — 02500C‡ 12.0 02500N‡ 9.0 2500/1875 02500V‡ 10.4/9.0

Page 91: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

90

907/905 SeriesIndustrial Sill-Height Convector

Industrial Sloped Top Sill-Height Convector

907

905 The 907/905 industrial sill-height convector (also known as draft bar-riers) are designed to fit under large windows to prevent cold down drafts. The heaters are ideal for heavy traffic areas with high heating requirements. • Installation Options: Units may be mounted to the wall flush on

the floor or on pedestals. Custom lengths and blank sections and inside or outside corners are available for wall-to-wall installations. Units can be ordered Option “S” with smooth painted finish when the back of the heater is visible.

• Length Options: Heaters can be installed singularly in lengths from 28.8 inches to 103.4 inches or joined end to end for complete perimeter heating.

• Added Safety: The sloped-top cabinet on the 905 Series pre-vents objects from being set on top of the heater, which can restrict airflow and cause overheating.

• Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes are also available.

Applications• Air, Rail or Bus Terminals

• Auditoriums

• Corridors

• Entryways

• Foyers

• Hallways

• Lobbies

• Offices

Standard Construction FeaturesHeating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet oper-ation.

Housing – Cabinet is constructed of 18-gauge steel with a 16-gauge steel front cover. The unit has an epoxy/polyester powder paint finish in white or almond. End caps are provid-ed on all units.

Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. The outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof).

Built-in Controls – Linear limit, automatic reset thermal cut-out.

Electrical Connection – Each baseboard heater has a junction box located on both ends and a built-in full length wireway.

Installation Requirements – Field or factory-installed low voltage relay and thermostat kits fit into the right-hand junction box only. Heaters 200 watt/ft or greater are not designed for residential use in the United States.

Standard Special Colors

Page 92: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

91

907/905 SeriesIndustrial Sill-Height ConvectorIndustrial Sloped Top Sill-Height Convector

Field-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

(1) Change 907 prefix to 905 for sloped top.Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.

Remote Room Thermostat – See pages 111-112.

Code Description

A Bottom Air InletD3 Disconnect Switch, 277V, Double-pole, 20 AmpL Custom Length

M1 High Altitude Automatic CutoutR1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 AmpR2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 AmpR6 Pneumatic Relay, 480V, 20 AmpR7 Triac Proportional Relay, 277V Max., 2500W Max.S Smooth painted finish on heater back

T1 Tamperproof Thermostat, Single-pole, 277V, 25 Amp

T2 Tamperproof Thermostat, Double-pole, 277V, 25 Amp with off position

T5 Adjustable Thermostat, Single-pole, 277V, 25 Amp

T6 Adjustable Thermostat, Double-pole, 277V, 25 Amp with off position

CatalogNumber Description

907-124597(1) Inside Corner907-124598(1) Outside Corner

907-124599 Round Pedestal Kit, 3-5”, Qty=2907-169807 Square Pedestal Kit, 2”, Qty=2

907-124600(1) Splice Plate 2” Long

907-124601(1) Contour Splice Plate for Code A (Bottom Air Inlet) and/or Heater with Pedestals

907-124602 24V Relay Kit, 240V, 22 Amp; 277V, 25 Amp907-124603 24V Relay Kit with Transformer, 120V, 22 Amp (2-wire only)907-124604 24V Relay Kit with Transformer, 208V, 22 Amp907-124605 24V Relay Kit with Transformer, 240V, 22 Amp907-124606 24V Relay Kit with Transformer, 277V, 19 Amp907B-XXX(1) Blank Section (specify length in inches-XXX)907-224755 Tamperproof Single-pole Thermostat Kit 277V, 25 Amp

907-224756 Tamperproof Double-pole Thermostat Kit 277V, 25 Amp with off position

907-224757 Single-pole Thermostat Kit 277V, 25 Amp

907-224758 Double-pole Thermostat Kit 277V, 25 Amp with off position

6-1/8"

2-1/2"

1-7/8"

1-3/8"

15/16"

4"

3-7/8"

1-1/8"

1-1/8"2-3/8"

7/8"

2-3/8"

K.O. 7/8"

K.O. 1/4"

905 Series

907 Series

7-1/2"

2-1/2"

1-7/8"

1-3/8"

15/16"

4"

3-7/8"

1-1/8"

1-1/8"2-1/2"

7/8"

2-3/8"

K.O. 7/8"

K.O. 1/4"

Page 93: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

92

905/907 SeriesIndustrial Sill-Height Convector

Industrial Sloped Top Sill-Height ConvectorHX-907U (Flat Top)HX-905U (Sloped Top)How to order: Model + Heater Code with color code + Options (example HX-905U01200NW-1710-T5)

LengthIn. (mm)

Density

Watts

Heater CodeWatts at

240/208V

Heater Code Weight Lbs (kg)

W/Ft W/m 120V (1 Ph) Amps 208V

(1 Ph) Amps 277V (1 Ph) Amps 240/208V

(1 Ph) Amps 907(Flat)

905 (Sloped)

28.8(733)

100 330 200 00200B‡-733 1.7 00200C‡-733 1.0 — — 200/150 00200V‡-733 0.8/0.7

10.4(4.8)

11.6(5.3)

150 490 300 00300B‡-733 2.5 00300C‡-733 1.4 00300N‡-733 1.1 300/225 00300V‡-733 1.3/1.1200 650 400 00400B‡-733 3.3 00400C‡-733 1.9 00400N‡-733 1.4 400/300 00400V‡-733 1.7/1.4275 900 500 00500B‡ 4.2 00500C‡ 2.4 00500N‡ 1.8 500/375 00500V‡ 2.1/1.8

38.8(987)

100 330 300 00300B‡-987 2.5 00300C‡-987 1.4 00300N‡-987 1.1 300/225 00300V‡-987 1.3/1.1

12.7(5.8)

15.1(6.9)

150 490 450 00450B‡-987 3.8 00450C‡-987 2.2 00450N‡-987 1.6 450/338 00450V‡-987 1.9/1.6200 650 600 00600B‡-987 5.0 00600C‡-987 2.9 00600N‡-987 2.2 600/450 00600V‡-987 2.5/2.2275 900 750 00750B‡ 6.3 00750C‡ 3.6 00750N‡ 2.7 750/563 00750V‡ 3.1/2.7

49(1248)

100 330 400 00400B‡-1248 3.3 00400C‡-1248 1.9 00400N‡-1248 1.4 400/300 00400V‡-1248 1.7/1.4

14.9(6.8)

18.7(8.5)

150 490 600 00600B‡-1248 5.0 00600C‡-1248 2.9 00600N‡-1248 2.2 600/450 00600V‡-1248 2.5/2.2200 650 800 00800B‡-1248 6.7 00800C‡-1248 3.8 00800N‡-1248 2.9 800/600 00800V‡-1248 3.3/2.9275 900 1000 01000B‡ 8.3 01000C‡ 4.8 01000N‡ 3.6 1000/750 01000V‡ 4.2/3.6

58.6(1489)

100 330 500 00500B‡-1489 4.2 00500C‡-1489 2.4 00500N‡-1489 1.8 500/375 00500V‡-1489 2.1/1.8

17.0(7.7)

22.0(10.0)

150 490 750 00750B‡-1489 6.3 00750C‡-1489 3.6 00750N‡-1489 2.7 750/563 00750V‡-1489 3.1/2.7200 650 1000 01000B‡-1489 8.3 01000C‡-1489 4.8 01000N‡-1489 3.6 1000/750 01000V‡-1489 4.2/3.6275 900 1250 01250B‡ 10.4 01250C‡ 6.0 01250N‡ 4.5 1250/938 01250V‡ 5.2/4.5

67.3(1710)

100 330 600 00600B‡-1710 5.0 00600C‡-1710 2.9 00600N‡-1710 2.2 600/450 00600V‡-1710 2.5/2.2

18.8(8.5)

25.0(11.4)

150 490 900 00900B‡-1710 7.5 00900C‡-1710 4.3 00900N‡-1710 3.2 900/675 00900V‡-1710 3.8/3.2200 650 1200 01200B‡-1710 10.0 01200C‡-1710 5.8 01200N‡-1710 4.3 1200/900 01200V‡-1710 5.0/4.3275 900 1500 01500B‡ 12.5 01500C‡ 7.2 01500N‡ 5.4 1500/1125 01500V‡ 6.3/5.4

76.6(1947)

100 330 700 00700B‡-1947 5.8 00700C‡-1947 3.4 00700N‡-1947 2.5 700/525 00700V‡-1947 2.9/2.5

20.8(9.4)

28.3(12.8)

150 490 1050 01050B‡-1947 8.8 01050C‡-1947 5.0 01050N‡-1947 3.8 1050/788 01050V‡-1947 4.3/3.8200 650 1400 01400B‡-1947 11.7 01400C‡-1947 6.7 01400N‡-1947 5.1 1400/1050 01400V‡-1947 5.8/5.0275 900 1750 — — 01750C‡ 8.4 01750N‡ 6.3 1750/1313 01750V‡ 7.3/6.3

85.4(2170)

100 330 800 00800B‡-2170 6.7 00800C‡-2170 3.8 00800N‡-2170 2.9 800/600 00800V‡-2170 3.3/2.9

22.7(10.3)

31.3(14.2)

150 490 1200 01200B‡-2170 10.0 01200C‡-2170 5.8 01200N‡-2170 4.3 1200/900 01200V‡-2170 5.0/4.3200 650 1600 — — 01600C‡-2170 7.7 01600N‡-2170 5.8 1600/1200 01600V‡-2170 6.7/5.8275 900 2000 — — 02000C‡ 9.6 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2

94.2(2395)

100 330 900 00900B‡-2395 7.5 00900C‡-2395 4.3 00900N‡-2395 3.2 900/675 00900V‡-2395 3.8/3.2

24.6(11.2)

34.4(15.6)

150 490 1350 — — 01350C‡-2395 6.5 01350N‡-2395 4.9 1350/1013 01350V‡-2395 5.6/4.9200 650 1800 — — 01800C‡-2395 8.7 01800N‡-2395 6.5 1800/1350 01800V‡-2395 7.5/6.5275 900 2250 — — 02250C‡ 10.8 02250N‡ 8.1 2250/1688 02250V‡ 9.4/8.1

103.4(2627)

100 330 1000 01000B‡-2627 8.3 01000C‡-2627 4.8 01000N‡-2627 3.6 1000/750 01000V‡-2627 4.2/3.6

26.6(12.1)

37.6(17.1)

150 490 1500 — — 01500C‡-2627 7.2 01500N‡-2627 5.4 1500/1125 01500V‡-2627 6.3/5.4

200 650 2000 — — 02000C‡-2627 9.6 02000N‡-2627 7.2 2000/1500 02000V‡-2627 8.3/7.2

200 650 2250 — — 02250C‡-2627 10.8 02250N‡-2627 8.1 2250/1688 02250V‡-2627 9.4/8.1

275 900 2500 — — 02500C‡ 12.0 02500N‡ 9.0 2500/1875 02500V‡ 10.4/9.0

Other single-phase voltages available, consult factory. ‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.

Page 94: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

93

910 SeriesAluminum Sill-Height Convection Heater

Applications• Air, Rail or Bus Terminals• Auditoriums• Corridors• Entryways• Foyers• Hallways• Lobbies• Offices• Commercial Buildings

The sleek, flowing curved aluminum front cover and end caps of the 910 Series offer a unique design for architectural applications. They are designed to fit under large windows to prevent cold down drafts. These heaters can provide total or supplemental heating for a variety of appli-cations. The rugged design is built to withstand years of hard usage for your commercial application.

• Easy to Install: Units may be mounted flush to the wall or directly to any floor surface. There are no screws on the front cover. Two rows of mounting holes on the back of the heater are spaced at 2 inch (51 mm) intervals for easy mounting. An electrical junction box is provided at each end of the unit for easy connection to the power wiring. To remove the cover, locate the locking tab at the bottom center of the heater. Rotate the tab counterclockwise with a tool through the air inlet and the cover can be withdrawn.

• Choice of colors: Heaters can be matched to any decor. White or metallic charcoal are standard and a wide range of optional colors and custom finishes are available (see optional color selections on inside back cover).

Standard Construction FeaturesHeating elements – Stainless steel elements with tight fitting aluminum fins float on high temperature nylon bushings for quiet and efficient operation.

Housing – Cabinet is constructed of 20-gauge galvanized steel with a robust aluminum front cover. The unit has an epoxy/polyester powder paint with a satin finish in white or metallic charcoal.

Inlet/Outlet Grilles – The fresh air inlet grille is located at the bottom of the front of the unit. The outlet is located at the top with openings less than 0.25” to discourage tampering with the heating element (pencil-proof).

Built-in Controls – Linear limit, automatic reset thermal cutout.

Electrical Connection – Each baseboard heater has a junction box located on both ends and a built-in full length wire way.

Installation Requirements – Field or factory-installed low voltage relay and thermostat kits fit into the right-hand junc-tion box only.

Standard Special ColorsSpecial ColorsSpecial Colors

Page 95: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

94

910 SeriesAluminum Sill-Height Convection Heater

Field-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

Code Description

D3 Disconnect Switch, 277V Max, Double-pole, 16 Amp

M1 High Altitude Automatic Cutout

R1 24V Relay, 240V, 22 Amp; 277V, 19 Amp

R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp

R7 24V TRIAC Proportional Relay

R8 24V TRIAC Proportional Relay with transformer

T1 Tamperproof Thermostat, Single-pole, 277V, 25 Amp

T2 Tamperproof Thermostat, Double-pole, 277V, 25 Amp with off position

T5 Adjustable Thermostat, Single-pole, 277V, 25 Amp

T6 Adjustable Thermostat, Double-pole, 277V, 25 Amp with off position

CatalogNumber Description

910-277363 Disconnect Switch, 277V, Double-pole, 16 Amp

910-277364 24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp

910-277365 24V Relay Kit with transformer, 120V, 25 Amp

910-277366 24V Relay Kit with transformer, 208V, 22 Amp

910-277367 24V Relay Kit with transformer, 240V, 22 Amp

910-277368 24V Relay Kit with transformer, 277V, 19 Amp

910-277369 24V TRIAC Proportional Relay, 277V, 15 Amp

910-277370 24V TRIAC Proportional Relay with transformer, 277V, 15 Amp

910-277371 Tamperproof Single-pole Thermostat Kit 277V, 25 Amp with off position

910-277372 Tamperproof Double-pole Thermostat Kit 277V, 25 Amp with off position

910-277373 Thermostat Kit Single-pole 277V, 25 Amp with off position

910-277374 Thermostat Kit Double-pole 277V, 25 Amp with off position

¶Standard colors - Add W for white finish or CM for metallic charcoal finish to the end of part number.Special or custom colors - see inside back cover for color codes to be added to end of part number.

Side View Bottom ViewRear View

46 mm1 13/16"

47 mm1 13/16"

113 mm4 7/16"

80 mm3 1/8"

73 mm2 7/8"

177 mm6 15/16"

162 mm6 3/8"

21 mm13/16"

104 mm4 1/8"

33 mm1 5/16"

27 mm1 1/16"

51 mm2"

KOE Ø22 mmKOE Ø7/8"

LengthWall Length = Length - 3/8" (9.5 mm)

KOE Ø22 mmKOE Ø7/8"

KOE Ø13 mmKOE Ø1/2"

Side View Bottom ViewRear View

46 mm1 13/16"

47 mm1 13/16"

113 mm4 7/16"

80 mm3 1/8"

73 mm2 7/8"

177 mm6 15/16"

162 mm6 3/8"

21 mm13/16"

104 mm4 1/8"

33 mm1 5/16"

27 mm1 1/16"

51 mm2"

KOE Ø22 mmKOE Ø7/8"

LengthWall Length = Length - 3/8" (9.5 mm)

KOE Ø22 mmKOE Ø7/8"

KOE Ø13 mmKOE Ø1/2"

Side View Bottom ViewRear View

46 mm1 13/16"

47 mm1 13/16"

113 mm4 7/16"

80 mm3 1/8"

73 mm2 7/8"

177 mm6 15/16"

162 mm6 3/8"

21 mm13/16"

104 mm4 1/8"

33 mm1 5/16"

27 mm1 1/16"

51 mm2"

KOE Ø22 mmKOE Ø7/8"

LengthWall Length = Length - 3/8" (9.5 mm)

KOE Ø22 mmKOE Ø7/8"

KOE Ø13 mmKOE Ø1/2"

Bottom View

Rear View

Side View

162 mm6-3/8”

177 mm6-15/16”

73 mm2-7/8”

46 mm1-13/16”

47 mm1-13/16”

113 mm4-7/16”

51 mm2”

80 mm3-1/8”

21 mm13/16”

33 mm1-5/16”

27 mm1-1/16”

104 mm4-1/8”

KOE 22 mmKOE 7/8”

KOE 22 mmKOE 7/8”

KOE 13 mmKOE 1/2”

LengthLength

Wall Length = Length - 3/8” (9.5 mm)

Remote Room Thermostat – See pages 111-112.

Page 96: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

95

910 SeriesAluminum Sill-Height Convection Heater

HX-910UHow to order: Model + Heater Code with color code + Options (example HX-910U01000BW-T5)

LengthIn.

(mm)

DensityWatts

Heater Code Watts at240/208V

Heater Code

W/Ft. W/m 120V Amps 208V Amps 277V Amps 240/208V Amps

24.6(625) 150 475 300 00300B‡ 2.5 00300C‡ 1.4 — — 300/225 00300V‡ 1.3/1.1

29.5(750)

125 400 300 00300B‡-750 2.5 00300C‡-750 1.4 00300N‡-750 1.1 300/225 00300V‡-750 1.3/1.1

200 675 500 00500B‡ 4.2 00500C‡ 2.4 00500N‡ 1.8 500/375 00500V‡ 2.1/1.8

39.5(1004)

150 500 500 00500B‡-1004 4.2 00500C‡-1004 2.4 00500N‡-1004 1.8 500/375 00500V‡-1004 2.1/1.8

225 750 750 00750B‡ 6.3 00750C‡ 3.6 00750N‡ 2.7 750/563 00750V‡ 3.1/2.7

49.8(1265)

175 600 750 00750B‡-1265 6.3 00750N‡-1265 3.6 00750N‡-1265 2.7 750/563 00750V‡-1265 3.1/2.7

250 800 1000 01000B‡ 8.3 01000C‡ 4.8 01000N‡ 3.6 1000/750 01000V‡ 4.2/3.6

59.3(1506)

200 650 1000 01000B‡-1506 8.3 01000C‡-1506 4.8 01000N‡-1506 3.6 1000/750 01000V‡-1506 4.2/3.6

250 850 1250 01250B‡ 10.4 01250C‡ 6.0 01250N‡ 4.5 1250/938 01250V‡ 5.2/4.5

68(1727)

225 725 1250 01250B‡-1727 10.4 01250C‡-1727 6.0 01250N‡-1727 4.5 1250/938 01250V‡-1727 5.2/4.5

275 875 1500 01500B‡ 12.5 01500C‡ 7.2 01500N‡ 5.4 1500/1125 01500V‡ 6.3/5.4

77.3(1964) 275 900 1750 — — 01750C‡ 8.4 01750N‡ 6.3 1750/1313 01750V‡ 7.3/6.3

86.1(2187)

200 700 1500 01500B‡-2187 12.5 01500C‡-2187 7.2 01500N‡-2187 5.4 1500/1125 01500V‡-2187 6.3/5.4

275 925 2000 — — 02000C‡ 9.6 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2

94.9(2412)

225 725 1750 — — 01750C‡-2412 8.4 01750N‡-2412 6.3 1750/1313 01750V‡-2412 7.3/6.3

300 925 2250 — — 02250C‡ 10.8 02250N‡ 8.1 2250/1688 02250V‡ 9.4/8.1

104.1(2644)

225 750 2000 — — 02000C‡-2644 9.6 02000N‡-2644 7.2 2000/1500 02000V‡-2644 8.36/7.2

250 850 2250 — — 02250C‡-2644 10.8 02250N‡-2644 8.1 2250/1688 02250V‡-2644 9.4/8.1

300 950 2500 — — 02500C‡ 12.0 01500N‡-2632 9 2500/1875 01500V‡-2632 10.4/9.0

Other single-phase voltages available, consult factory. All models listed are single-phase.

Standard colors - Add W for white finish or CM for metallic charcoal finish to the catalog number when ‡ is indicated.

Special or custom colors - See inside back cover for color codes to be added to the catalog number where ‡ is indicated.

Page 97: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

96

909

908

The 909/908 Series architectural convectors are designed to heat large commercial spaces without the fan noise associ-ated with unit heaters.• Installation Options: Units may be mounted to the wall,

flush on the floor or on pedestals. Custom lengths, blank sections, sub-bases and inside or outside corners are available for wall-to-wall installations. Units and accesso-ries can be ordered with smooth painted finish when the back of the heater is visible.

• Added Safety: The sloped-top cabinet on the 908 Series prevents objects from being set on top of the heater, which can restrict airflow and cause overheating.

• Recessed Mounting: The 909 Series heater can be fully recessed when the front warm air outlet option is used.

• Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes are also available.Applications

• Banks

• Classrooms

• Conference Rooms

• Halls

• Offices

Standard Construction FeaturesHeating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet oper-ation.

Housing – Cabinet is constructed of 20-gauge steel with a 16-gauge steel front cover. The unit has an epoxy/polyester powder paint finish in white or almond.

Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. An extruded aluminum outlet grille discour-ages tampering with the heating element.

Built-in Controls – Linear limit, automatic reset thermal cut-out.

Installation Requirements – Field or factory-installed low voltage relay and thermostat kits. These units are not designed for residential use in the United States.

Rough In Dimensions – 909 Series only: Heater Length + 1” wide x 15” high x 6” deep.

909/908 SeriesArchitectural Convector

Architectural Sloped Top Convector

Standard Special Colors

Page 98: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

97

909/908 SeriesArchitectural ConvectorArchitectural Sloped Top Convector

Field-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

(1) Change 909 prefix to 908 for sloped top.Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.Empty cabinet sections can be cut to length in the field.

Remote Room Thermostat – See pages 111-112.

Code Description

D1 Disconnect Switch, Three-pole, 600V, 32 Amp

F Front Air outlet (BAI Only)

R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp

R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp

R3 24V Double-pole Relay, 240V, 25 Amp; 277V, 19 Amp

R4 240V Relay, Single-pole, 240V, 25 Amp

R5 240V Relay, Double-pole, 240V, 25 Amp

R6 Pneumatic Relay, 480V, 20 Amp

R7 Triac Proportional Relay, 277V Max., 2500W Max.

S Smooth painted finish on heater back

T1 Tamperproof Thermostat, Single-pole, 240V, 30 Amp; 480V, 15 Amp

T2 Tamperproof Thermostat, Double-pole, 480V, 15 Amp

X1 240V Transformer - 50 VA

X2 24V Transformer - 50 VA

CatalogNumber Description

909-124609 Flat top corner (interior and exterior)

908-124609 Sloped top inside corner

908-218356 Sloped outside corner

909-124610 Square Pedestal Kit 3 (76) High

909-124611

Sub BaseHeater Length

In. (mm)

27.2 (690)

909-124612 37.2 (944)

909-124613 47.2 (1198)

909-124614 57.2 (1452)

909-124615 65.2 (1655)

909-124616 75.2 (1909)

909-124617 83.2 (2112)

909-218276(1)

Empty CabinetLength

In. (mm)

27.2 (690)

909-218277(1) 37.2 (944)

909-218278(1) 47.2 (1198)

909-218279(1) 57.2 (1452)

909-218280(1) 65.2 (1655)

909-218281(1) 75.2 (1909)

909-218282(1) 83.2 (2112)

909-124618

Recessed Trim KitHeater Length

In. (mm)

27.2 (690)

909-124619 37.2 (944)

909-124620 47.2 (1198)

909-124621 57.2 (1452)

909-124622 65.2 (1655)

909-124623 75.2 (1909)

909-124624 83.2 (2112)

909-124628(1) Control Box - 12” 12 (305)

909-124629 24V Relay Kit, Single-pole, 240V, 22 Amp; 277V, 19 Amp

909-124630 24V Relay Kit, Double-pole, 240V, 25 Amp

909-124631 240V Relay Kit, Single-pole, 240V, 22 Amp

909-124632 240V Relay Kit, Double-pole, 240V, 25 Amp

909-124633 24V Relay Kit with Transformer, 208V, 22 Amp

909-124634 24V Relay Kit with Transformer, 240V, 22 Amp

909-124635 24V Relay Kit with Transformer, 277V, 19 Amp

909-124636 Transformer Kit-208/24V - 50 VA

909-124637 Transformer Kit-240/24V - 50 VA

909-124638 Transformer Kit-277/24V - 50 VA

Page 99: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

98

909/908 SeriesArchitectural Convector

Architectural Sloped Top Convector

908 Series

909 Series

K.O. Ø1/4"

K.O. Ø7/8"

8-1/32" 4"

2-1/32" 2-1/32"

2"

2"

2-27/32"

4-1/32"

5-3/16"

2-1/32"

2-21/32"

2-1/32"

2-9/32"

2-21/32"

7-17/32"

2"

4"

4-15/32"

L

4"

4-15/32"

14-1/16"

2-31/32"

K.O. 1-1/8" K.O. 1/4"K.O. 7/8"

K.O. 1/4"

K.O. 1-1/8"

2”

2”

14”

3”

8-1/2”

7-1/2”

4-1/2”

2”

2-1/4”5-3/16”

K.O. 1-1/8” - 7/8”

K.O. 1-1/8” - 7/8”

K.O. 1/4”

Page 100: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

99

14”

5-3/16”

909/908 SeriesArchitectural ConvectorArchitectural Sloped Top ConvectorHX-909U (Flat Top)HX-908U (Sloped Top)How to order: Model + Heater Code with color code + Options (example HX-909U02000NW-1655-T1)

LengthIn.

(mm)

Density

Watts

Heater CodeWatts at

240/208V

Heater Code Weight Lbs (kg)

W/Ft W/m 208V (1 Ph) Amps 277V

(1 Ph) Amps 240/208V(1 Ph) Amps 909

(Flat)908

(Sloped)

27.2 (690)

375 1250 800 00800C‡-690 3.8 00800N‡-690 2.9 800/600 00800V‡-690 3.3/2.9 30 (13.6)

32.0(14.5)500 1640 1000 01000C‡ 4.8 01000N‡ 3.6 1000/750 01000V‡ 4.2/3.6

37.2 (944)

375 1250 1000 01000C‡-944 4.8 01000N‡-944 3.6 1000/750 01000V‡-944 4.2/3.6 46 (20.9)

46(20.9)500 1640 1500 01500C‡ 7.2 01500N‡ 5.4 1500/1125 01500V‡ 6.3/5.4

47.2 (1198)

375 1250 1500 01500C‡-1198 7.2 01500N‡-1198 5.4 1500/1125 01500V‡-1198 6.3/5.4 57(25.9)

57(25.9)500 1640 2000 02000C‡ 9.6 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2

57.2 (1452)

375 1250 1750 01750C‡-1452 8.4 01750N‡-1452 6.3 1750/1313 01750V‡-1452 7.3/6.3 66 (29.9)

66(30)500 1640 2500 02500C‡ 12.0 02500N‡ 9.0 2500/1875 02500V‡ 10.4/9.0

65.2 (1655)

375 1250 2000 02000C‡-1655 9.6 02000N‡-1655 7.2 2000/1500 02000V‡-1655 8.3/7.2 75 (34.0)

75(34.1)500 1640 3000 03000C‡ 14.4 03000N‡ 10.8 3000/2250 03000V‡ 12.5/10.8

75.2 (1909)

375 1250 2500 02500C‡-1909 12.0 02500N‡-1909 9.0 2500/1875 02500V‡-1909 10.4/9.0 80 (36.3)

80(36.3)500 1640 3500 03500C‡(1) 16.8 03500N‡ 12.6 3500/2625 03500V‡ 14.6/12.6

83.2 (2112)

375 1250 2750 02750C‡-2112 13.2 02750N‡-2112 9.9 2750/2066 02750V‡-2112 11.5/9.9 89 (40.4)

89(40.5)500 1640 4000 04000C‡(1) 19.2 04000N‡ 14.4 4000/3000 04000V‡ 16.7/14.4

Other single-phase voltages available, consult factory.

‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.

Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.(1) If control option R7 is required for these heaters, (Qty 2) R7 Triac proportional relays are required.

Page 101: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

100

914 SeriesMini Draft Barrier Heater

The 914 Series mini draft barrier heaters are designed to fit under large windows to prevent cold down drafts. The heater provides total or supplemental heating for a variety of appli-cations. • Installation Options: Units may be wall mounted or

installed on the floor using pedestal kits. Custom lengths, blank sections, and inside or outside corners are available for wall-to-wall installations. Units can be ordered with Option “S” smooth painted finish back plate when the back of the heater is visible.

• Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes including anodized aluminum are available.

Applications• Commercial Buildings

• Entryways

• Hallways

• Schools

Standard Construction FeaturesHeating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet operation.

Housing – Cabinet is constructed of 18-gauge steel with a 14-gauge aluminum front and top covers. The unit has an epoxy/polyester powder paint finish in white or almond. End caps are provided on all units.

Inlet/Outlet Grilles – The fresh air inlet is located on the bot-tom of the unit. The top outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof).

Built-in Controls – Linear limit, automatic reset thermal cutout.

Electrical Connection – Each heater has a junction box located at the right end and a built-in full length wireway. Separate low voltage wireway is available.

Mounting Requirements – Minimum installation height above the floor is two inches. Field or factory-installed low voltage relay and thermostat kits fit into the right-hand junction box only. These units are not for residential use in the United States.

Standard Special Colors

Page 102: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

101

914 SeriesMini Draft Barrier Heater

Field-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.

(2) For anodize aluminum finished heaters, smooth back is affixed with rivets.

Remote Room Thermostat – See pages 111-112.

Shown with optional square pedestal.

Top View

Rear View

Side View

2-1/2”

2”

3-3/16”

4-1/2”

1”

1-5/8”

3-3/4”

K.O. 7/8”

Front View

Sufficient Height2” from Floor

Code Description

D3 Disconnect Switch, Double-pole, 277V, 16 Amp

F1 24V Wireway

L Custom Length

M1 High Altitude Automatic Cutout

R1 24V Relay, 240V, 22 Amp; 277V, 19 Amp; 600V, 10 Amp

R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp

R6 Pneumatic Relay, 480V, 20 Amp

R7 Triac Proportional Relay 277V Max., 2500W Max.

S Smooth painted finish on heater back (2)

T1 Tamperproof Thermostat, Single-pole, 277V, 25 Amp

T2 Tamperproof Thermostat, Double-pole, 277V, 25 Amp with off position

T5 Adjustable Thermostat, Single-pole, 277V, 25 Amp; 600V, 10 Amp

T6 Adjustable Thermostat, Double-pole, 277V, 25 Amp with off position

CatalogNumber Description

914-166740 Inside Corner

914-166741 Outside Corner

914-166742 Round Pedestal Kit, 3-5”, Qty 2

914-166743 Square Pedestal Kit, 2”, Qty 2

914-166744 Splice Plate 2” Long

914-166745 Contoured Splice Plate for Code S (smooth painted finish on heater back) and/or Heater with Pedestals

941-1666746 24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp

914-166747 24V Relay Kit with Transformer, 208V, 22 Amp

914-166748 24V Relay Kit with Transformer, 240V, 22 Amp

914-166749 24V Relay Kit with Transformer, 277V 19 Amp

914B-XXX Blank Section (specify length in inches-XXX)

914-224761 Tamperproof Single-pole Thermostat Kit 277V, 25 Amp; 600V, 10 Amp

914-224762 Tamperproof Double-pole Thermostat Kit 277V, 25 Amp; 600V, 10 Amp with off position

914-224763 Single-pole Thermostat Kit 277V, 25 Amp; 600V, 10 Amp

914-224764 Single-pole Thermostat Kit 277V, 25 Amp; 600V, 10 Amp with off position

Smooth Finish on heater back (S) Standard Finish on heater back

Page 103: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

102

914 SeriesMini Draft Barrier Heater

Other voltages available, consult factory.

‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.

Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated

HX-914UHow to order: Model + Heater Code with color code + Options (example HX-914U00400NW-1200-T5)

LengthIn. (mm)

DensityWatts

Heater CodeWatts

240/208V

Heater CodeWeight Lbs (kg)W/Ft W/m 208V

(1 Ph) Amps 277V(1 Ph) Amps 480V

(1 Ph) Amps 240/208V(1 Ph) Amps

27.6 (700)

150 490 300 00300C‡-700 1.4 00300N‡-700 1.1 — — 300/225 00300V‡-700 1.3/1.1 7 (3.2)175 574 350 00350C‡ 1.7 00350N‡ 1.3 — — 350/263 00350V‡ 1.5/1.3

35.4(900)

100 330 300 00300C‡-900 1.4 00300N‡-900 1.1 00300T‡-900 0.6 300/225 00300V‡-900 1.3/1.18.3

(3.8)150 490 450 00450C‡-900 2.2 00450N‡-900 1.6 00450T‡-900 0.9 450/338 00450V‡-900 1.9/1.6

175 574 525 00525C‡ 2.5 00525N‡ 1.9 00525T‡ 1.1 525/394 00525V‡ 2.2/1.9

47.3(1200)

100 330 400 00400C‡-1200 1.9 00400N‡-1200 1.4 00400T‡-1200 0.8 400/300 00400V‡-1200 1.7/1.410.2(4.6)150 490 600 00600C‡-1200 2.9 00600N‡-1200 2.2 00600T‡-1200 1.3 600/450 00600V‡-1200 2.5/2.2

175 574 700 00700C‡ 3.4 00700N‡ 2.5 00700T‡ 1.5 700/526 00700V‡ 2.9/2.5

59.1(1500)

100 330 500 00500C‡-1500 2.4 00500N‡-1500 1.8 00500T‡-1500 1.0 500/375 00500V‡-1500 2.1/1.812

(5.5)150 490 750 00750C‡-1500 3.6 00750N‡-1500 2.7 00750T‡-1500 1.6 750/563 00750V‡-1500 3.1/2.7

175 574 875 00875C‡ 4.2 00875N‡ 3.2 00875T‡ 1.8 875/657 00875V‡ 3.6/3.2

70.9(1800)

100 330 600 00600C‡-1800 2.9 00600N‡-1800 2.2 00600T‡-1800 1.3 600/450 00600V‡-1800 2.5/2.213.9(6.3)150 490 900 00900C‡-1800 4.3 00900N‡-1800 3.2 00900T‡-1800 1.9 900/675 00900V‡-1800 3.8/3.2

175 574 1050 01050C‡ 5.0 01050N‡ 3.8 01050T‡ 2.2 1050/789 01050V‡ 4.4/3.8

82.7(2100)

100 330 700 00700C‡-2100 3.4 00700N‡-2100 2.5 00700T‡-2100 1.5 700/525 00700V‡-2100 2.9/2.515.8(7.2)150 490 1050 01050C‡-2100 5.0 01050N‡-2100 3.8 01050T‡-2100 2.2 1050/788 01050V‡-2100 4.4/3.8

175 574 1225 01225C‡ 5.9 01225N‡ 4.4 01225T‡ 2.6 1225/920 01225V‡ 5.1/4.4

94.5(2400)

100 330 800 00800C‡-2400 3.8 00800N‡-2400 2.9 00800T‡-2400 1.7 800/600 00800V‡-2400 3.3/2.917.6(8)150 490 1200 01200C‡-2400 5.8 01200N‡-2400 4.3 01200T‡-2400 2.5 1200/900 01200V‡-2400 5.0/4.3

175 574 1400 01400C‡ 6.7 01400N‡ 5.1 01400T‡ 2.9 1400/1052 01400V‡ 5.8/5.1

Page 104: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

103

916 SeriesHigh Watt Density Draft Barrier Heater

The 916 Series high watt density draft barrier heaters are designed to fit under large windows to prevent cold down drafts. The heater provides total or supplemental heating for a variety of applications. • Installation Options: Units may be wall mounted or

installed on the floor using pedestal kits. Custom lengths, blank sections and inside or outside corners are available for wall-to-wall installations. Units can be ordered with smooth painted finish back plate when the back of the heater is visible. These units are not, however, designed for residential use.

• Choice of Colors: Heaters can be matched to any décor. White or almond is standard and a wide range of optional colors and custom finishes, including anodized aluminum, are also available.

Applications• Commercial Buildings

• Entryways

• Hallways

• Hospitals

• Shopping Centers

Standard Construction FeaturesHeating Elements – Two stainless steel elements with alu-minum fins float on high temperature nylon bushings for quiet operation.

Housing – Cabinet is constructed of 18-gauge steel with a 14-gauge aluminum front and top covers. The unit has an epoxy/polyester powder paint finish in white or almond. End caps are provided on all units.

Inlet/Outlet Grilles – The fresh air inlet is located on the bot-tom of the unit. The top outlet grille has openings less than 0.25 inches to discourage tampering with the heating element (pencil-proof).

Built-in Controls – Linear limit, automatic reset thermal cutout.

Electrical Connection – Each heater has a junction box located at the right end and a built-in full length wireway. Seprate low voltage wireway is available.

Installation Requirements – Minimum installation height above the floor is three inches. Field or factory-installed low voltage relay and thermostat kits fit into the right-hand junction box only. These units are not for residential use in the United States.

Standard Special Colors

Page 105: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

104

916 SeriesHigh Watt Density Draft Barrier Heater

Field-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

Shown with optional square pedestals.

Top View

Rear View Side View

Front View

Sufficient Height3” from Floor

Standard Finish on heater backSmooth Finish on heater back - (S)

Code Description

D1 Disconnect Switch, Three-pole, 600V, 32 Amp

D3 Disconnect Switch, Double-pole, 277V, 16 Amp

F1 24V Wireway

L Custom Length

M1 High Altitude Automatic Cutout

R1 24V Relay, 240V, 22 Amp; 277V, 19 Amp; 600V, 10 Amp

R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp

R6 Pneumatic Relay, 480V, 20 Amp

R7 Triac Proportional Relay 277V Max., 2500W Max.

S Smooth painted finish on heater back (2)

T1 Tamperproof Thermostat, Single-pole, 240V, 25 Amp; 600V, 10 Amp

T2 Tamperproof Thermostat, Double-pole, 240V, 25 Amp; 600V, 10 Amp

T5 Adjustable Thermostat, Single-Pole 277V, 25 Amp, 600V, 10 Amp

T6 Adjustable Thermostat, Double-Pole 277V, 25 Amp, 600V, 10 Amp

CatalogNumber Description

916-166753 Inside Corner

916-166754 Outside Corner

916-166756 Square Pedestal Kit, 3”, Qty 2

916-166757 Splice Plate 2” Long

916-166758Contoured Splice Plate for Code S (smooth painted finish on heater back) and/or Heater with Pededstals

916-166759 24V Relay Kit, 240V, 22 Amp; 277V, 19 Amp

916-166760 24V Relay Kit with Transformer, 208V, 22 Amp

916-166761 24V Relay Kit with Transformer, 240V, 22 Amp

916-166762 24V Relay Kit with Transformer, 277V 19 Amp

916B-XXX Blank Section (specify length in inches-XXX)

916-224765 Tamperproof Thermostat, Single-pole, 240V, 25 Amp; 600V, 10 Amp

916-224766 Tamperproof Thermostat, Double-pole, 240V, 25 Amp; 600V, 10 Amp

916-264350 Adjustable Single-pole Thermostat Kit 240V, 25 Amp; 600V, 10 Amp with off position

916-264351 Adjustable Double-pole Thermostat Kit 240V, 25 Amp; 600V, 10 Amp with off position(2) For anodize aluminum finished heaters, smooth back is affixed with rivets.

Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.

Remote Room Thermostat – See pages 111-112.

5-3/4”

K.O. 1/4”

K.O. 7/8”

6”

1-7/8”

2-1/4”3-3/16”

3”

3-3/16”

Page 106: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

105

916 SeriesHigh Watt Density Draft Barrier HeaterHX-916UHow to Order: Model + Heater Code with color code + Options(example HX-916U00875CW-1500-T1)

Other voltages available, consult factory.

‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.

Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.

LengthIn. (mm)

DensityWatts

Heater CodeWatts at

240/208V

Heater CodeWeightLbs (kg)W/Ft W/m 208V

(1 Ph) Amps 277V(1 Ph) Amps 480V

(1 Ph) Amps 240/208V(1 Ph) Amps

23.6(600)

175 575 375 00375C‡-600 1.8 00375N‡-600 1.4 — — 375/281 00375V‡-600 1.6/1.4

10.7(4.8)

250 820 500 00500C‡-600 2.4 00500N‡-600 1.8 — — 500/375 00500V‡-600 2.1/1.8

355 1165 750 00750C‡ 3.6 00750N‡ 2.7 — — 750/563 00500V‡ 3.1/2.7

500 1640 1000 01000C‡-600 4.8 01000N‡-600 3.6 01000T‡-600 2.1 1000/750 01000V‡-600 4.2/3.6

35.4(900)

175 575 500 00500C‡-900 2.4 00500N‡-900 1.8 00500T‡-900 1.0 500/375 00500V‡-900 2.1/1.8

14.1(6.4)

250 820 750 00750C‡-900 3.6 00750N‡-900 2.7 00750T‡-900 1.6 750/563 00750V‡-900 3.1/2.7

355 1165 1000 01000C‡ 4.8 01000N‡ 3.6 01000T‡ 2.1 1000/751 01000V‡ 4.2/3.6

500 1640 1500 01500C‡-900 7.2 01500N‡-900 5.4 01500T‡-900 3.1 1500/1125 01500V‡-900 6.3/5.4

47.3(1200)

175 575 700 00700C‡-1200 3.4 00700N‡-1200 2.5 00700T‡-1200 1.5 700/525 00700V‡-1200 2.9/2.5

17.6(8.0)

250 820 1000 01000C‡-1200 4.8 01000N‡-1200 3.6 01000T‡-1200 2.1 1000/750 01000V‡-1200 4.2/3.6

355 1165 1400 01400C‡ 6.7 01400N‡ 5.1 01400T‡ 2.9 1400/1052 01400V‡ 5.8/5.1

500 1640 2000 02000C‡-1200 9.6 02000N‡-1200 7.2 02000T‡-1200 4.2 2000/1500 02000V‡-1200 8.3/7.2

59.1(1500)

175 575 875 00875C‡-1500 4.2 00875N‡-1500 3.2 00875T‡-1500 1.8 875/656 00875V‡-1500 3.6/3.2

21.1(9.6)

250 820 1250 01250C‡-1500 6.0 01250N‡-1500 4.5 01250T‡-1500 2.6 1250/938 01250V‡-1500 5.2/4.5

355 1165 1750 01750C‡ 8.4 01750N‡ 6.3 01750T‡ 3.6 1750/1314 01750V‡ 7.3/6.3

500 1640 2500 02500C‡-1500 12 02500N‡-1500 9.0 02500T‡-1500 5.2 2500/1875 02500V‡-1500 10.4/9.0

70.9(1800)

175 575 1050 01050C‡-1800 5.0 01050N‡-1800 3.8 01050T‡-1800 2.2 1050/788 01050V‡-1800 4.4/3.8

24.6(11.1)

250 820 1500 01500C‡-1800 7.2 01500N‡-1800 5.4 01500T‡-1800 3.1 1500/1125 01500V‡-1800 6.3/5.4

355 1165 2100 02100C‡ 10.1 02100N‡ 7.6 02100T‡ 4.4 2100/1577 02100V‡ 8.8/7.6

500 1640 3000 03000C‡-1800 14.4 03000N‡-1800 10.8 03000T‡-1800 6.3 3000/2250 03000V‡-1800 12.5/10.8

82.7(2100)

175 575 1225 01225C‡-2100 5.9 01225N‡-2100 4.4 01225T‡-2100 2.6 1225/919 01225V‡-2100 5.1/4.4

28.0(12.7)

350 820 1750 01750C‡-2100 8.4 01750N‡-2100 6.3 01750T‡-2100 3.6 1750/1313 01750V‡-2100 7.3/6.3

355 1165 2450 02450C‡ 11.8 02450N‡ 8.8 02450T‡ 5.1 2450/1840 02450V‡ 10.2/8.8

500 1640 3500 03500C‡-2100 16.8 03500N‡-2100 12.6 03500T‡-2100 7.3 3500/2625 03500V‡-2100 14.6/12.6

94.5(2400)

175 575 1400 01400C‡-2400 6.7 01400N‡-2400 5.1 01400T‡-2400 2.9 1400/1050 01400V‡-2400 5.8/5.0

31.5(14.3)

250 820 2000 02000C‡-2400 9.6 02000N‡-2400 7.2 02000T‡-2400 4.2 2000/1500 02000V‡-2400 8.3/7.2

355 1165 2800 02800C‡ 13.5 02800N‡ 10.1 02800T‡ 5.8 2800/2103 02800V‡ 11.7/10.1

500 1640 4000 04000C‡-2400 19.2 04000N‡-2400 14.4 04000T‡-2400 8.3 4000/3000 04000V‡-2400 16.7/14.4

Page 107: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

106

912

911

The 912/911 convectors are designed to heat large com-mercial spaces. They provide large amounts of heat without the fan noise associated with unit heaters.• Installation Options: Units may be mounted to the wall,

flush on the floor or on pedestals. 912 Series units can be fully recessed when the front warm air outlet option is used. These units are not for residential use in the United States.

• Added Safety: The sloped-top cabinet on the 911 Series prevents objects from being set on top of the heater, which can restrict airflow and cause overheating.

• Wall-to-Wall Installation: A smooth painted finish back plate is available so that the unit can be mounted against glass walls.

Applications• Classrooms

• Conference Rooms

Standard Construction FeaturesHeating Elements – Stainless steel elements with aluminum fins float on high temperature nylon bushings for quiet opera-tion.

Housing – Cabinet is constructed of 20-gauge steel with a 16-gauge steel front cover. The unit has an epoxy/polyester powder paint finish in white or almond. Mounting holes are provided along the back of the cabinet for wall installation.

Inlet/Outlet Grilles – The fresh air inlet grille is located on the front of the unit. An extruded aluminum outlet grille discour-ages tampering with the heating elements.

Built-in Controls – Linear limit, automatic reset thermal cutout.

Rough In Dimensions – 912 Series only: Heater Length + 1” wide x 21” high x 6” deep.

912/911 SeriesArchitectural Cabinet Convector

Architectural Sloped Top Cabinet Convector

Standard Special Colors

• Hallways

• Lobbies

Page 108: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

107

912/911 SeriesArchitectural Cabinet ConvectorArchitectural Sloped Top Cabinet Convector

Field-Installed Options (shipped loose for field installation into heater)

Factory Built-in Options

(1) Change 912 prefix to 911 for CASI.Standard colors - Add W for white finish or A for almond finish to the end of part number.Special or custom colors - See inside back cover for color codes to be added to end of part number.Empty cabinet sections can be cut to length in the field.

Remote Room Thermostat – See pages 111-112.

Code Description

D1 Disconnect Switch, Three-pole, 600V, 32 Amp

F Front Air outlet (CAI Only)

R1 24V Relay, Single-pole, 240V, 22 Amp; 277V, 19 Amp

R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp

R3 24V Double-pole Relay, 240V, 25 Amp; 277V, 19 Amp

R4 240V Relay, Single-pole, 240V, 25 Amp

R5 240V Relay, Double-pole, 240V, 25 Amp

R6 Pneumatic Relay, 480V, 20 Amp

R7 Triac Proportional Relay, 277V Max., 2500W Max.

S Smooth painted finish on heater back

T1 Tamperproof Thermostat, Single-pole, 240V, 30 Amp; 480V, 15 Amp

T2 Tamperproof Thermostat, Double-pole, 480V, 15 Amp

X1 240V Transformer - 50 VA

X2 24V Transformer - 50 VA

CatalogNumber Description

912-124546 CAI Corner (interior and exterior)

911-124546 CASI inside corner

911-218358 CASI outside corner

912-124547 Universal Round Pedestal Kit 3 (76) High

912-124548

Sub BaseHeater Length

In. (mm)

27.2 (690)

912-124549 37.2 (944)

912-124550 47.2 (1198)

912-124551 57.2 (1452)

912-124552 65.2 (1655)

912-218283(1)

Empty CabinetLength

In. (mm)

27.2 (690)

912-218284(1) 37.2 (944)

912-218285(1) 47.2 (1198)

912-218286(1) 57.2 (1452)

912-218287(1) 65.2 (1655)

912-124553

Recessed Trim KitHeater Length

In. (mm)

27.2 (690)

912-124554 37.2 (944)

912-124555 47.2 (1198)

912-124556 57.2 (1452)

912-124557 65.2 (1655)

912-124561(1) Control Box - 12” 12 (306)

912-124562 24V Relay Kit, Single-pole, 240V, 22 Amp; 277V, 19 Amp

912-124563 24V Relay Kit, Double-pole, 240V, 25 Amp; 277V, 19 Amp

912-124564 240V Relay Kit, Double-pole, 240V, 25 Amp

912-124565 240V Relay Kit, Single-pole, 240V, 22 Amp

912-124566 24V Relay Kit with Transformer, 208V, 22 Amp

912-124567 24V Relay Kit with Transformer, 240V, 22 Amp

912-124568 24V Relay Kit with Transformer, 277V, 19 Amp

912-124569 Transformer Kit-208/24V - 50 VA

912-124570 Transformer Kit-240/24V - 50 VA

912-124571 Transformer Kit-277/24V - 50 VA

912-224767 (1) Tamperproof Thermostat, Single-pole, 240V, 30 Amp; 480V, 15 Amp

912-224768 (1) Tamperproof Thermostat, Double-pole 480V, 15 Amp

Page 109: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

108

912/911 SeriesArchitectural Cabinet Convector

Architectural Sloped Top Cabinet Convector

911 Series

912 Series

Unit with Grille On Top

Rear View

Rear View

K.O. 4”x 2”

K.O. 1/4”

K.O. 7/8”

K.O. 7/8”

K.O. 1/4”

2”

8-15/32”

4-1/32”

5-3/16”

K.O. 1/4”

K.O. 1-1/8”

K.O. 1-1/8”

K.O. 7/8”

K.O. 7/8”

8-1/2”8”

8”

6”

6”

2”

2”

L

12-1/2”

20-3/16”

2-1/2”

7-1/4”

5-3/16”

Bottom View

Bottom View

Front View

LeftSide View

LeftSide View

Unit with Grille On Front (Option F)

2”

Page 110: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

109

K.O. 7/8”

K.O. 1/4”

2”

8-15/32”

4-1/32”

8-1/2”

12-1/2”

5-3/16”

2”

912/911 SeriesArchitectural Cabinet ConvectorArchitectural Sloped Top Cabinet ConvectorHX-912U (Flat Top)HX-911U (Sloped Top)How to order: Model + Heater Code with color code + Options (example: HX-912U03000CW-1198-T1)

LengthIn. (mm)

Density

Watts

Heater CodeWatts at

240/208V

Heater Code Weight Lbs (kg)

W/Ft W/m 208V(1 ph) Amps 240V

(1 ph) Amps 277V(1 ph) Amps 240/208V

(1 ph) Amps 912(Flat)

911(Sloped)

27.2 (690)

500 1640 1000 01000C‡-690 4.8 01000J‡-690 4.2 01000N‡-690 3.6 1000/750 01000V‡-690 4.2/3.637

(16.8)37

(16.8)750 2450 1500 01500C‡-690 7.2 01500J‡-690 6.3 01500N‡-690 5.4 1500/1125 01500V‡-690 6.3/5.4

1000 3280 2000 02000C‡ 9.6 02000J‡ 8.3 02000N‡ 7.2 2000/1500 02000V‡ 8.3/7.2

37.2 (944)

500 1640 1500 01500C‡-944 7.2 01500J‡-944 6.3 01500N‡-944 5.4 1500/1125 01500V‡-944 6.3/5.447

(21.3)47

(21.3)750 2450 2250 02250C‡-944 10.8 02250J‡-944 9.4 02250N‡-944 8.1 2250/1690 02250V‡-944 9.4/8.1

1000 3280 3000 03000C‡ 14.4 03000J‡ 12.5 03000N‡ 10.8 3000/2250 03000V‡ 12.5/10.8

47.2 (1198)

500 1640 2000 02000C‡-1198 9.6 02000J‡-1198 8.3 02000N‡-1198 7.2 2000/1500 02000V‡-1198 8.3/7.257

(25.9)57

(25.9)750 2450 3000 03000C‡-1198 14.4 03000J‡-1198 12.5 03000N‡-1198 10.8 3000/2250 03000V‡-1198 12.5/10.8

1000 3280 4000 04000C‡ 19.2 04000J‡ 16.7 04000N‡ 14.4 4000/3000 04000V‡ 16.7/14.4

57.2 (1452)

500 1640 2500 02500C‡-1452 12.0 02500J‡-1452 10.4 02500N‡-1452 9.0 2500/1875 02500V‡-1452 10.4/9.067

(30.4)67

(30.4)750 2450 3750 03750C‡-1452 18.0 03750J‡-1452 15.6 03750N‡-1452 13.5 3750/2817 03750V‡-1452 15.6/13.5

1000 3280 5000 05000C‡ 24.0 05000J‡ 20.8 05000N‡ 18.1 5000/3750 05000V‡ 20.8/18.0

65.2 (1655)

500 1640 3000 03000C‡-1655 14.4 03000J‡-1655 12.5 03000N‡-1655 10.8 3000/2250 03000V‡-1655 12.5/10.879

(35.8)79

(35.8)750 2450 4500 04500C‡-1655 21.6 04500J‡-1655 18.8 04500N‡-1655 16.2 4500/3380 04500V‡-1655 18.8/16.3

1000 3280 6000 06000C‡ 28.8 06000J‡ 25.0 06000N‡ 21.7 6000/4500 06000V‡ 25.0/21.6

LengthIn. (mm)

Density

Watts

Heater CodeWatts at

240/208V

Heater Code Weight Lbs (kg)

W/Ft W/m 208V (3 ph) Amps 240V

(3 ph) Amps 480V (3 ph) Amps 240/208V

(3 ph) Amps 912(Flat)

911(Sloped)

27.2 (690)

500 1640 1000 01000D‡-690 2.8 01000K‡-690 2.4 01000U‡-690 1.2 1000/750 01000P‡-690 2.8/2.137

(16.8)37

(16.8)750 2450 1500 01500D‡-690 4.2 01500K‡-690 3.6 01500U‡-690 1.8 1500/1125 01500P‡-690 3.6/3.1

1000 3280 2000 02000D‡ 5.6 02000K‡ 4.8 02000U‡ 2.4 2000/1500 02000P‡ 4.8/4.2

37.2 (944)

500 1640 1500 01500D‡-944 4.2 01500K‡-944 3.6 01500U‡-944 1.8 1500/1125 01500P‡-944 3.6/3.147

(21.3)47

(21.3)750 2450 2250 02250D‡-944 6.2 02250K‡-944 5.4 02250U‡-944 2.7 2250/1690 02250P‡-944 5.4/4.7

1000 3280 3000 03000D‡ 8.3 03000K‡ 7.2 03000U‡ 3.6 3000/2250 03000P‡ 7.2/6.2

47.2 (1198)

500 1640 2000 02000D‡-1198 5.6 02000K‡-1198 4.8 02000U‡-1198 2.4 2000/1500 02000P‡-1198 4.8/4.257

(25.9)57

(25.9)750 2450 3000 03000D‡-1198 8.3 03000K‡-1198 7.2 03000U‡-1198 3.6 3000/2250 03000P‡-1198 7.2/6.2

1000 3280 4000 04000D‡ 11.1 04000K‡ 9.6 04000U‡ 4.8 4000/3000 04000P‡ 9.6/8.3

57.2 (1452)

500 1640 2500 02500D‡-1452 6.9 02500K‡-1452 6.0 02500U‡-1452 3.0 2500/1875 02500P‡-1452 6.0/5.267

(30.4)67

(30.4)750 2450 3750 03750D‡-1452 10.4 03750K‡-1452 9.0 03750U‡-1452 4.5 3750/2817 03750P‡-1452 9.0/7.8

1000 3280 5000 05000D‡ 13.9 05000K‡ 12.0 05000U‡ 6.0 5000/3750 05000P‡ 12.0/10.4

65.2 (1655)

500 1640 3000 03000D‡-1655 8.3 03000K‡-1655 7.2 03000U‡-1655 3.6 3000/2250 03000P‡-1655 7.2/6.279

(35.8)79

(35.8)750 2450 4500 04500D‡-1655 12.5 04500K‡-1655 10.8 04500U‡-1655 5.4 4500/3380 04500P‡-1655 10.8/9.4

1000 3280 6000 06000D‡ 16.7 06000K‡ 14.4 06000U‡ 7.2 6000/4500 06000P‡ 14.4/12.5

Other voltages available, consult factory.

‡Standard colors - Add W for white finish or A for almond finish to the end of catalog number when ‡ is indicated.

Special or custom colors - See inside back cover for color codes to be added to end of catalog number where ‡ is indicated.For three-phase units a double pole relay or thermostat is required.

Page 111: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

110

Thermostat Section Chart

Thermostat Selection ChartPage 50 53 56 57 58 60 62 66 70 72 74 75 76 80

933 932 935 940 934 930 922 936/937 931 941 938 939 AS 918

901-1006998 X(1) X(1) X(1) X(1) X(1) X(4)

901-1007030 X(2)

901-OTH824 X(1) X(1) X(1) X(1) X(1) X(4)

901-124640 X X X X X X X X X X X X

901-124642 X X X X X X X X X X X X

901-124643 X X X X X X X X X X X X

901-219981 X(1) X(1) X(1) X(1) X(1)

901-OTH2750 901-OTH2750P X(3) X(3) X(3) X(3) X(3) X(3) X

901-OTH4000 901-OTH4000P X(3) X(3) X(3) X(3) X(3) X(3) X

901-OTH5007 901-OTH5007P X

901-OTH-TH114-A-240D X X X X X X X

R-101 & R-102 X X

SR-240/120 X

(1) Option R2 is required - 24V relay with transformer or relay without transformer (for more than one heater on the same thermostat)(2) Option N2 is required - 2-Speed Motor w/High-Low Relay 24V(3) Thermostat has to be set for fan mode(4) Requires a field installed 24V relay with transformer: 901-RT840T-240 for 208/240V or 901-24A05A-1 for 120V

Page 112: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

111

Thermostats

CatalogNumber

SwitchType Color Type Tamper-

proofThermo-

meterAmps @

120-240VAmps

@ 277VPilotDuty

PositiveOff

Tempera-ture

Range 0F

901-1006998 Bimetal White SPST No No – – 30VA at 30V max Yes 50-90

901-219981 Bimetal White SPST No No – – 30VA at 30V max Yes 45-95

CatalogNumber

SwitchType Color Type Tamper-

proofThermo-

meterAmps @

120-240VAmps

@ 277VPilotDuty

PositiveOff

Tempera-ture

Range 0F

901-124640 Bimetal Beige SPST No No 22 19 – No 40-80

901-124642Bimetal White

SPSTNo No 22 19 –

No40-80

901-124643 DPST Yes

901-TH114-A-240D

Electronic White

DPST

Yes Digital

15A@208 & 240 – – Yes

40-86

901-OTH2750

Pulse

11.5 – –

No

901-OTH2750P 11.5 16 –

901-OTH4000 16.7 – –

901-OTH4000P 16.7 – –

901-OTH5007 – 14.4 –

901-OTH5007P – 14.4 –

CatalogNumber

SwitchType Color Type Tamper-

proofThermo-

meterAmps @

120-240VAmps @

277VOutputSignal

PositiveOff

Tempera-ture

Range 0F

901-1016941 Electronic Beige DC Pulse No No – –20mA Max

at 8 VDCNo 50-90

901-OTH824 Electronic White Pulse Yes Digital – – 24VAC (.5A) No 40-86

901-TH115-AF-024T-15S Electronic WhitePulse

(15 min. cycle)

No Digital – – 24VAC (.5A) No 40-86

901-TH115-AF-024T/U Electronic WhitePulse

(15 min. cycle)

No Digital – – 24VAC (.5A) No 40-86

Low Voltage Thermostats (Applicable when R2 Option is included)

Line Voltage Thermostats (APPLICABLE WHEN ON/OFF LINE VOLTAGE CONTROL IS REQUIRED)

Low Voltage Electronic Thermostats (Applicable when R7 TRIAC Option is included)

Low Voltage Electronic Thermostats (Requires option R2 or an on/off relay with transformer)

Catalog Number

Switch Type Color Type Tamper-

proofThermo-

meterAmps @

120-240VAmps @

277VOutput Signal

Positive Off

Temperature Range oF

901-OTH824 Electronic White Pulse Yes Digital — — 24VAC No 40-85

Page 113: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

112

Controllers and Accessories

ControllersCatalogNumber Description Amps @

120-240VAmps @

277VInputSignal

901-RT850 Triac Relay without transformer (pulsing) 120/208/240/277 V 23 23 24 VAC &4-32 VDC

901-RT850T-240 Triac Relay with transformer 208/240 V 23 – 24 VAC

901-RT850T-277 Triac Relay with transformer 277 V – 23 24 VAC

901-RC840 On-Off Relay without transformer 120/208/240/277 V 22 18 –

901-RC840T-240 On-Off Relay with transformer 208/240 V 22 – –

901-24A05A-1 On-Off Relay with transformer 25 – –

901-RC840T-277 On-Off Relay with transformer 277 V – 18 –

Accessories -CatalogNumber Description

901-124644 Inside dimensions: 6-3/8” x 3-1/2”, 3” (depth)

901-F29-0198 Inside dimensions: 8-1/4” x 5-3/8”, 3-1/2” (depth)

901-OTH824901-1006998

901-219981901-1016941 901-TH114-A-240D

901-OTH 4000P901-124640901-124642901-124643

901-OTH 4000901-OTH2750P

901-OTH2750

901-OTH5007

901-RT850901-RT850T-240

901-RC840901-RC840T240902-RC840T-277

901-124644901-F29-0198

Clear universal thermostat guard. Protects both line and low voltage thermostats against vandalism, damage, and unauthorized adjustment of thermostat settings.

Page 114: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

113

White (W)

Almond (A)

Metallic Silver (AE)

Bronze (BZ)

Semi-Gloss Black (BK)

Aluminum(AL)

Metallic Charcoal(CM)

Standard Colors 900 Series Special Colors 900 Series

Refer to catalog listings for standard and special color avail-ability. Use color codes in parentheses when specifying and ordering. Custom colors are also available on 900 Series. Special and Optional Colors subject to setup charges. Colors represented are approximate.

Color Selection Chart

WhiteRed

Camel

Grey Yellow Blue Textured Beige

Standard Color 240 Series

Optional Colors 240 Series

Page 115: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

114

Limited Warranty

Heatrex new products are warranted against defects in workmanship, material, design, labeling and packaging. No other warranty, expressed or implied, written or oral, applies. No person other than an officer or the general manager of Heatrex is authorized to give any other warranty or assume any liability.

Warranty Period

Warranty periods differ between product lines. See chart on following page for item specific warranty periods.

Conditions of Warranty

Heatrex products must be installed, operated, and maintained in accordance with Heatrex’s instructions. Indeeco is not liable for damage or unsatisfactory performance of the product resulting from accident, negligence, alteration, unauthorized repair, improper application or installation of the product, improper specifications, or corrosion. HEATREX IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Claims against carriers for damage in transit must be filed by the purchaser with the carrier.

Remedy

Contact Heatrex sales department at (314) 333-5500 or [email protected], for a Return Material Authorization Number (RMA#) and return instructions.

If after receipt of the product and the claim, Heatrex finds to its reasonable satisfaction that the product is defective in workmanship, material, design, labeling or packaging, the product will be repaired or replaced, or the purchase price refunded at Heatrex’s option. There will be no charge to the purchaser for parts or labor. Removal and reinstallation of the product, and shipment of the product to Heatrex for repair or inspection, shall be at the purchaser’s risk and expense.

THE REPAIR, REPLACEMENT, OR REFUND PROVIDED FOR IN THIS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE PURCHASER. THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE TERMS OF THIS LIMITED WARRANTY.

Page 116: electric heating products - Meadvile, PA-Heatrex Unit Htrs/c2390... · electric heating products commercial & industrial explosion-proof unit heater explosion-proof convectorwashdown/corrosion

Heatrex Product Line Warranty Period903 5 years* and lifetime on heating element904 10 years*905 1 year*906 10 years*907 1 year*908 1 year*909 1 year*910 10 years* and lifetime on heating element911 1 year*912 1 year*914 1 year*916 10 years*918 10 years*920 5 years*922 5 years*925 3 years*926 1 year*928 3 years*930 5 years*931 1 year*932 5 years*933 5 years*934 5 years*935 2 years* and 5 years* on heating element936 5 years*937 5 years*938 1 year*939 1 year*940 2 years* and 5 years* on heating element941 1 year*

All Other Product Lines18 months from the date of shipment from Heatrex’s factory, or 12 months from the date the product is first placed into service,

whichever period lapses first.

*From date of shipment from Heatrex’s factory.