Fresh water is an increasingly scarce, precious and expensive resource. Saving water is now an essential part of our drive to a sustainable society. Delivering clean tap water requires more and more effort, energy and expense. 242 244 STORAGE PUMPS COMPLETE PACKAGED PUMP SOLUTIONS RAINMAIN SYSTEMS 250 254 CONTROLLERS FILTRATION RAINWATER HARVESTING SYSTEMS Harvested roof rainwater is not only a free resource, but it is ideal for use in wash- ing machines, toilet flushing and garden watering, in homes, in commerce, in public buildings and in industry. Our products, with their individual proven designs, are available to meet the widest possible range of uses in rainwater harvesting and management. 08 COMPLETE PACKAGED PUMP STATIONS 1300 ALLPUMPS (255 786) www.allpumps.com.au RAINWATER HARVESTING SYSTEMS IRRIGATION ABOVE GROUND RAIN WATER TANK 238 239

Upload: others

Post on 23-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

Fresh water is an increasingly scarce, precious and expensive resource. Saving water is now an essential part of our drive to a sustainable society. Delivering clean tap water requires more and more effort, energy and expense.

242 244STORAGE PUMPS

COMPLETE PACKAGED PUMP SOLUTIONS

RAIN

MAI

N SY

STEM

S

250 254CONTROLLERS FILTRATION

RAINWATER HARVESTINGSYSTEMS

Harvested roof rainwater is not only a free resource, but it is ideal for use in wash-ing machines, toilet flushing and garden watering, in homes, in commerce, in public buildings and in industry.

Our products, with their individual proven designs, are available to meet the widest possible range of uses in rainwater harvesting and management.

08

COMPLETE PACKAGED PUMP STATIONS1300 ALLPUMPS (255 786) www.allpumps.com.au

RAINWATER HARVESTINGSYSTEMS

IRRIGATION ABOVE GROUND RAIN WATER TANK

rainmain rainmain

238 239

Page 2: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S240 241

rainmain

TITLE:

SIZE CODE DWG No: REV

SCALE SHEET

DATE REVISED BY

AQUAFLO - 1 OFF 7500 TANK& RAINMAN C/W NASTEC BOREHOLEPUMP MODEL 4HS 04/05

AF11-890 0

2 of 3N.T.S

A3 N/A

DRAWN BY: P.LEE

DATE: 4/11/2011ALL DIMENSIONS IN MM

A DIVISION OFALL-PUMPS SALES & SERVICE

83 - 87 FENNELL ST, PARRAMATTA

NSW. 2150.PH: + 61 2 8838 1000FAX: + 61 2 9630 0369

EMAIL: [email protected]

1 OFF SUBMERSIBLE BOREHOLE PUMPMODEL NASTEC 4HS 04/05

C/W Ø100 PVC SHROUDALL MOUNTED ON UNISTRUT

SUPPORTING FRAME & CLAMPS

WASHING MACHINE

TOILETS

TAPS

NOTES:MATERIAL = HIGH DENSITY POLYETHYLENE ( HDPE )MATERIAL COLOR = BLACKWEIGHT OF HORIZONTAL TANK = 550 KGVOLUME = 7500 LITERS REFER STANDARD DRAWINGSHC11-200 CLASS D LIDHC11-300 CLASS B LID

WATER HARVESTING SYSTEM GUIDERAINMAIN

TYPICAL ABOVE GROUND INSTALLATION

TITLE:

SIZE CODE DWG No: REV

SCALE SHEET

DATE REVISED BYKWIKFLO - RAIN HARVESTING SYSTEM

KF11-7000 0

1 of 1N.T.S

A3 N/A

DRAWN BY: P.LEE

DATE: 1/6/2012ALL DIMENSIONS IN MM

NOTES:-

A DIVISION OFALL-PUMPS SALES & SERVICE

83 - 87 FENNELL ST, PARRAMATTA

NSW. 2150.PH: + 61 2 8838 1000FAX: + 61 2 9630 0369

EMAIL: [email protected]

TYPICAL BELOW GROUND INSTALLATION

Water storage is an integral part of any rainwater harvesting system important points to consider which will affect the storage capacity & type required is:

- Annual rainfall- Catchment area- Above or below ground storage- Water usage

Water Storage

Pumps are required in a rainwater harvesting system to pump the harvested water from your storage tank to the required discharge point such as irrigation, toilet flushing, wash down etc. important points to take into account when designing the pump system are:

- Submersible pumps (installed inside the water storage tank)- Above ground pumps (installed outside the water storage tank)- Pressure (discharge head to outlet)- Flow rate (number of outlets)- Number of pumps required

Pumps

The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water is used, this is to ensure the system will not fail to supply water at the required discharge points even when harvested water is not available. When choosing a controller that best suits your rain water harvesting system important points to take into account are:

- Discharge line size- Voltage- Indicators required (tank level, rain or mains water in use, pump status etc.)

Controller

Filtration is used on a rainwater harvesting system before the water enters the storage tank & on the discharge side of the pump system pump out of the tank. Filtration is required to make the harvested water as clean as possible before entering tank by removing leaves & sticks etc. Filtration used on the discharge side of the harvesting system is to remove finer particles & discolored water if required. Important points to take into account for filtration are:

- Inlet pipe size & flow to storage tank- Discharge flow, pressure- Water quality required

Filtration

RAINMAIN

Page 3: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S242 243

rainmainROUND & SLIMLINE TANKSABOVE GROUND STORAGE

FEATURES

Multiple brass outlets moulded in tank

Stainless steel mesh leaf strainer and overflow fittings

Moulded from the highest UV protection polyethylene

Austalian Standard AS/NZS 4766:2006 certification

ROUND TANKS

CODECAPACITY(APPROX)

DIAMETERINLET

HEIGHTOVERALLHEIGHT

638litres mm mm mm

2000L 1300 2000 2000

655litres mm mm mm

3000L 1410 2145 2200

680litres mm mm mm

3000L Squat 1720 1630 1720

682litres mm mm mm

5000L 1820 2145 2200

681litres mm mm mm

5000L Squat 2000 1800 1880

683litres mm mm mm

7500L 2180 2145 2300

622litres mm mm mm

10,000L 2550 2210 2350

685litres mm mm mm

11,000L 2750 1900 2000

619litres mm mm mm

22,000L 3500 2700 3030

SLIMLINE TANKS

CODECAPACITY(APPROX)

DIAMETERINLET

HEIGHTOVERALLHEIGHT

677litres mm mm mm

1200L L=1860W=450 1940 1940

678litres mm mm mm

2000L L=2000W=650 2110 2110

632litres mm mm mm

2100L L=2280W=700 1955 1955

616litres mm mm mm

2600L L=1970W=1000 1870 1870

635litres mm mm mm

3000L L=2570W=790 2170 2170

679litres mm mm mm

3000L L=2850W-680 2215 2215

674litres mm mm mm

5000L L=2950W=1450 2000 2000

BELOW GROUND STORAGE

HORIZONTAL MODELS LITRES "A" "B" "C" WEIGHT MANHOLE

AF 5H 5,000 3,500 mm 2,150 mm 1,900 mm 400 kg 1 @ 900 x 600 mm

AF 7.5H 7,500 4,500 mm 2,150 mm 1,900 mm 550 kg 1 @ 900 x 600 mm

AF 10H 10,000 5,500 mm 2,150 mm 1,900 mm 700 kg 1 @ 900 x 600 mm

AF 15H 15,000 7,500 mm 2,150 mm 1,900 mm 950 kg 1 @ 900 x 600 mm

AF 20H 20,000 9,500 mm 2,150 mm 1,900 mm 1,200 kg 1 @ 900 x 600 mm

AF 25H 25,000 2,150 mm 2,150 mm 1,900 mm 1,400 kg 1 @ 900 x 600 mm

AF 30H 30,000 13,500 mm 2,150 mm 1,900 mm 1,700 kg 1 @ 900 x 600 mm

Rainwater tanks, manufactured to the highest quality standards & designed to suit most applications, Rainmain rainwater tanks come in a large number of sizes to suit every need.

Page 4: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S244 245

rainmainMULTI STAGE PUMP WITH IN-BUILT PRESSURE CONTROLPUMPS

APPLICATIONS

Domestic boosting

Fountains and water features

Irrigation

Filling and emptying of tanks

Industrial wash down

Treatment of drinkable water

Cooling systems

TECHNICAL FEATURES

Pump body: Techno Polymer

Motor body: stainless steel Aisi 304

Back bracket: stainless steel Aisi 304

Shaft: stainless steel Aisi 416

Impellers: Techno Polymer

Diffuser: Techno-polymer

Mechanical seal: silicon-silicon

Cooled motor (by water) of Class F and Service S1 with thermic protection

Electric power cable HO7RN-f mt. 10 with plug

Protection class of the pump / motor IP 68

Temperature of the pumped liquid fom +2 C to + 37 C

INSTALLATION, SUITABLE FOR:

Surface installation

Submerged installation

Clean water, without abrasive and suspended parts

AUTOMATIC VERSION

Electronic board with Microprocessor

Flow sensor with cobalt Samario magnets

Run dry protection

Automatic stop and start

CODEVOLT.

NORMINAL POWER P2

CAPACITORINPUT CURRENT

AMP.

1230

Q

CAPACITYTOTAL HEADS

HZ50 KW HP UF VC 0 10 20 30 40 50 60

XAJE-120 230 0,90 1,2 20 450 7,2 HM 49 43 38 32 30 24 8

Hydraulic Performance Table

Size & WeightCODE

DIMENSIONS WEIGHT

A N H H1 N1 DNM DNA KG

XAJE-120 477 200 226 163 136 1"1/4 1' 13

PUMPS

50Hz

10 20 30 10 50 60 70 80 (GPM)

90

80

70

60

50

40

30

20

10

0

50 2 4 6 8 10 12 14 16 18 20 Q (m³/h)

0 50 100 150 200 250 300 (L/min)

H(ft)

240

200

160

120

80

40

0

H(M)

Hea

d

Flow

MT46

MT84

Performance Curve

APPLICATIONS

Fire booster System.

Mains booster Service.

Clean water transfer, irrigation.

Water treatment, Circulation, Reverse osmosis.

Industrial Cleaning, circulation of liquid.

FEATURES

Multi-stage Design - provides quiet, vibration

free operation.

Casing Seal - reliable high pressure sealing easy

Disassembly for maintenance or repair.

Stages: 304 stainless steel.

Mechanical Seal: carbon/ceramic/buna.

Close coupled electric motor with IP55 protection.

MODELOUTPUT CONNECTIONS RATED SYMBOLS DIMENSION WEIGHT

HP kW mm INCH HEAD (m) FLOW (LPM) HEAD (m) FLOW (LPM) L X W X H (mm) kg

MT-46 2 1.5 32 1 - 1/4" 60 65 79 110 495 x 170 x 210 11

MT-84 2 1.5 32 1 - 1/4" 37 133 42 300 513 X 152 X 225 22

NO. DESCRIPTION MATERIAL

1 Inlet Body Cast Iron

2 Impeller PPO

3 Guide Plate NBR

4 Casing 304SS

5 Mechanical Seal CA/CE

6 Outlet Body Cast Iron

7 Pump Shaft 304SS

8 Bearing CNM5K

9 Motor Laminated Steel + Wiring

10 Bowl SUS304

MT SERIES

(m)

Page 5: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S246 247

rainmain

3J AV E L I N - V E R T I C A L M U LT I S TA G E C E N T R I F U G A L P U M P S

C O N T E N T S

Performance Scope

H[m]400

300

200

100

80

60

40

30

20

10

0.7 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100 120 Q[m3/h]

JVI/JVN50Hz

JV1JVI1JVN1

JV3JVI3JVN3

JV5JVI5JVN5

JV10JVI10JVN10

JV15JVI15JVN15

JV20JVI20JVN20

JV32JVI32JVN32

JV45JVI45JVN45

JV64JVI64JVN64

JV90JVI90JVN90

JAVELIN PUMPPUMPS

JAVELIN PUMPPUMPS

Water supply and pressure boosting: Pressure boosting in buildings, hotels, residential complexes, pressure booster stations, supply of water networks, pressure boosting for industrial water supply.

Light industry: Washing and cleaning systems, car washing facilities fire fighting systems, process water systems, machine tools (cooling lubricants).

Heating, ventilation and air-conditioning: boilers, induction heating, heat exchangers, refrigerators, coolingtowers and systems, temperature control systems.

Irrigation and agriculture: greenhouses, sprinkler irrigation, flood irrigation.

Water Treatment: Water softeners and demineralization, reverse osmosis systems, distillation systems, filtration, ultra-filtration system.

The JV,JVI and JVN pumps are non-self priming vertical multistage pump of inline design, threaded, flanged or with victaulic coupling with equally sized suction and discharge ports. Stage construction with stainless steel impellers, chambers and pressure casing. Pump shaft & motor shaft of the IEC-standard motor are directly close coupled.

All pumps are equipped with a cartridge type mechanical seal for easy maintenance.

JV, JVI and JVN pumps have different pump sizes and various number of stages to provide the flow and the pressure required.

Squirrel cage, aluminium or cast iron casing up to 45 kW, totally enclosed, fan-cooled, 2-pole standard motor.Enclosed class: IP55Insulation class: FStandard voltage: P2:0.37 - 7.5 kW : 3 x 220 - 240V/380 - 415 V P2: From 11 kW 3 x 380 - 415 VThe motors have efficiency values that fall within the range referred to as MEPS2Ambient temperature: Max. + 50°C

Electric Motors

Pump

Applications

Page 6: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S248 249

rainmain4HSPUMPS

Pump Selection ChartVariable speed allows 4HS to cover a wide range of water flow and heads with only few models; selecting the proper pump model for an application will help maximize the performance and overall efficiency of the application. Use the diagram below to select the most suitable 4HS pump model for your application.

COMPARED TO CONVENTIONAL SOLUTIONS 4HS OFFERS:

Energy-saving operation.

Quick and simplified application.

System reliability.

4HS IS A RANGE OF 4” ELECTRIC SUBMERSIBLE PUMPS FOR BORE APPLICATIONS, FEATURING:

Three-phase water-filled asynchronous motor with encapsulated resin stator, fully constructed of AISI 304 stainless steel.

Built-in integrated inverter controlled by CM control module.

Multistage pump made of AISI 304 stainless steel.

INVERTER ALLOWS 4HS TO:

Change pump speed to maintain set-pressure regardless of water demand. Thus, the pump is operated only when and as needed without wasting energy, and extending pump life.

Starts and stops pump gently, thus reducing peak absorption, mechanical stress.

Protects pump and drive from overload, surges, under/over - voltage, dry running, and any abnormal conditions.

ULTRAFLOW SUBMERSIBLE PUMPPUMPS

ULTRAFLOW 5”multistage submersible pumps are a compact, robust product. These quality pumps areconstructed from 304 grade stainless steel. They offer an extensive performance range and have been proven to perform reliably and efficiently in many demanding applications around the world. These high pressure multistage submersible pumps are ideal for domestic water supply, pressure boosting, irrigation, treated effluent distribution, fountains, 6” bore & well dewatering, ULTRAFLOW 5” multistage submersible pumps can be installed in conjunction with a variety of control systems including conventional pressure switch controllers, pressure & flow switch controllers and variable frequency drives. Because the ULTRAFLOW 5”submersible pumps are installed in the actual water source, there can be no loss of prime, noise levels are almost nonexistent and being out of sight, they cannot be tampered with or vandalized.

SPECIFICATIONS

Maximum working pressure: 10 Bar

Discharge size: 1.25 inches (32mm) BSP

Maximum immersion: 20 m, (60ft)

Maximum solids size up to 2 mm

Class F insulation, IP68 protection

Duty rating: Continuous either vertical or horizontal up to maximum ambient temperature of 40ºC

Maximum starts per hour: 20

Available in 240 or 415 volt

Floatswitch available on 240 volt models only

20 m power cable type H07RN F supplied with AU/NZ 2-3 pin plug

Can be installed horizontally or vertically

APPLICATIONS

Energy-saving operation.

Quick and simplified application.

System reliability.

Fountains

Treated effluent distribution

Page 7: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S250 251

rainmain

PART NO. PRODUCT DESCRIPTION

FPC-12720'OEM VERSION'

Housed in a robust, weatherproof, poly carbonate enclosure, this unit is ideal for OEMs who require a control system to compliment a pressure pumping system. The unit is supplied without any cablepenetrations providing the installer complete installation versatility.

FPC-12721‘Quick Plug’DIY Version

Sharing the same enclosure as the ‘OEM Version’, the DIY model has been pre-fitted with sockets for the pump, valve and float switch connections. Allthese connections differ from each other making it impossible to incorrectly connect the unit. This is an excellent feature for installa-tions where appropriately qualified tradesman are not available.

FPC-12724 &FPC-12725Industrial/CommercialVersion

For Industrial and Commercial applications such as playing fields, golf courses and large commercial properties, where a ‘high flow’ system is required, standard controllers for both Heavy Duty 1 Phase 240Vac and 3 Phase 415Vac pumps are available. Housed in a lockable metal enclosure, the FPC-12724 and FPC-12725 controllers are equipped with contactorsand overloads compatible for pumps (1Ph or 3Ph) rated up to13amps Full Load current.

CONTROLLER DESCRIPTIONSRAINMAIN SYSTEMS

SchematicThe unique MATelec Rain/Mains Water Controller is designed to provide a continuous supply of water for a variety of uses, whilst prioritising and maximising the usage of Rain Water.The system comprises a Controller, a unique Valve and a Liquid Level Switch. The controller not only monitors the level of stored Rain Water, switching the valve accordingly, but also provides a switched output for the control of power to a pressure pumping system. If Rain Water becomes available, the valve through which Mains Water is being supplied, is automatically pulsed closed by the controller, and at the same time, the 240Vac pump output contacts are energised. In the event of either ‘Rain Water Depletion’ or ‘Power Failure’ the controller will immediately pulse the valve open, and de-energise the pump output contacts. The controller has a ‘System Test’ function which, if initiated, changes the status of the system to enable the operator to check pump and valve function at the press of a button.

FEATURES & RANGERAINMAIN SYSTEMS

Common Features

FEATURES INCLUDE

Unlimited pump options, Single or Three Phase, above ground or submersible

Compatiable with an entire range of high flow, low 'head loss' valves

No pressure reducing valves

No continously actuated solenoid valves

Test Button - Provides change of system status, including pump and valve switching

Indicator Lights provide 'power' and 'valve' status information

Pump protections feature - If Rain Water is depleted, switching of pump output isolates power to pressure pump system

Controller can be situated up to 50m from storage tank

Ideal for Industrial, Commercial and/or Domestic applications

PART NO. PUMPVOLTAGE

CONTACTOR/OVERLOAD

MAX CURRENT

ENCLOSURETYPE

FPC-12720 240Vac None 6Amps Poly

FPC-12721 240Vac None 6Amps Poly

FPC-12724-A 240Vac Yes 2.5 - 4Amps 103 *

FPC-12724-B 240Vac Yes 4 - 6Amps 103 *

FPC-12724-C 240Vac Yes 6 - 9Amps 103 *

FPC-12724-D 240Vac Yes 9 - 13Amps 103 *

FPC-12725-A 415Vac Yes 2.5 - 4Amps 103 *

FPC-12725-B 415Vac Yes 4 - 6Amps 103 *

FPC-12725-C 415Vac Yes 6 - 9Amps 103 *

FPC-12725-D 415Vac Yes 9 - 13Amps 103 *

Page 8: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S252 253

rainmainWIRING DIAGRAM & COMPONENT LAYOUTRAINMAIN SYSTEMS

Australia

®

Wiring DiagramRain/Mains Water Controllers

Section 8

PUMP240Vac

A1

A2

CONTROLCIRCUITBREAKER

240VacCOIL

E A N

E

A

N

VALVEFLOATSWITCH

PRESSURESWITCH

ISOLATORTOL

CONTACTOR

TOLN

A

E

SU

PP

LYE

N

A

PU

MP

KEYPAD

PR

ES

SU

RE

FLO

AT

VA

LVE

+ -

RAIN/MAINS WATER CONTROLLER

®

Australia

R1 TOL

RELAYCOIL

PUMPFAULTLIGHT

LOW VOLTAGE DEVICES

240V

ac S

UP

PLY

FPC-12724 1 Phase FPC-12724 1 Phase

WIRING DIAGRAM & COMPONENT LAYOUTRAINMAIN SYSTEMS

Australia

®

Component Layout

Rain/Mains W

ater Controllers

OFF

CONTROLCIRCUIT

CONTACTOR

OVERLOAD

Low LevelFloat

Switch

Valve+ -

LowPressureSwitch

Low Voltage Connections240VacOutput

240VacSupply

E A N E A N

RAIN/MAINS WATERCONTROLLER

N

A

ES

UP

PLY

E

N

AP

UM

P

KEYPAD

PR

ES

SU

RE

FLO

AT

VA

LVE

+ -

RELAY

Component Layout

Enclosure 103See Section 5 for Enclosure details

Model FPC-12724 1 Phase

Section 8

OFF

ON

MAIN ISOLATOR

PUMP FAULT

Rain/Mains WaterController

DO NOT REMOVE COVER - AUTHORISED PERSONS ONLYDANGER HIGH VOLTAGE

SYSTEMTEST

Press to changeSystem Status

MAINSWATER

TANKWATER

FPC-SERIES

Internal Door

FPC-12724 1 Phase

Australia

®

Wiring DiagramRain/Mains Water Controllers

Section 8

FPC-12725 3 Phase

PUMP415Vac

A1

A2

CONTROLCIRCUITBREAKER

240VacCOIL

E A A A

N

E

A1

A2

A3

1 2 3

ISOLATOR SWITCH

TOL

CONTACTOR

TOL

VALVEFLOATSWITCH

PRESSURESWITCH

RAIN/MAINS WATER CONTROLLER

N

A

ES

UP

PLY

E

N

AP

UM

P

KEYPAD

PR

ES

SU

RE

FLO

AT

VA

LVE

+ -

®

Australia

R1

TOL

RELAYCOIL

PUMPFAULTLIGHT

415V

ac S

UP

PLY

LOW VOLTAGE DEVICES

FPC-12725 3 Phase

Australia

®

Component Layout

Rain/Mains W

ater Controllers

Section 8

415Vac Supply 415Vac Pump

E A A A N E P P P1 2 3 1 2 3

OFF

CONTROLCIRCUIT

CONTACTOR

OVERLOAD

RAIN/MAINS WATERCONTROLLER

N

A

ES

UP

PLY

E

N

AP

UM

P

KEYPAD

PR

ES

SU

RE

FLO

AT

VA

LVE

+ -

RELAY

Low LevelFloat

Switch

Valve+ -

LowPressureSwitch

Low Voltage Connections

Component Layout

Enclosure 103See Section 5 for Enclosure details

Model FPC-12725 3 Phase

OFF

ON

MAIN ISOLATOR

PUMP FAULT

Rain/Mains WaterController

DO NOT REMOVE COVER - AUTHORISED PERSONS ONLYDANGER HIGH VOLTAGE

SYSTEMTEST

Press to changeSystem Status

MAINSWATER

TANKWATER

FPC-SERIES

Internal Door

FPC-12725 3 Phase

Page 9: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S254 255

rainmainFIRST FLUSH DIVERTERSRAINMAIN

DescriptionRainwater Filter for installation in the lower section of the downpipe. It is easy to monitor due to its installation position in the downpipe. No need to lift heavy lids or to climb down into storage tanks, as required when filters are installed underground. The downpipe filter where the cleaned rainwater flows out down the filter pipe.

The Rainwater downpipe filter is also ideal for re-fitting of equipments which are not disposing of a filter. Simple installation and maintenance depending on contamina-tion. To clean, slide the filter unit out, and brush off any dirt.Connection capacity for roof areas up to 70 m²Max. Flow Rate Sieve insert aprox. 0,6 l/sec = aprox. 2 m³ cleaned water per hour.Installation in standpipes at Ø 80 or 110 mm. The upper connection can accept metal downpipes of 80 and 100.

The cleaned water can be used in washing machines, toilet flushing and garden watering, in homes, in commerce, in public buildings and in industry.

Technical DataInstallation in standpipes at Ø 80 or 110 mm. The upper connection can accept metal downpipes of 80 and 100.

The filter is aprox. 50,5 cm high and 17 cm wide. It needs very little space behind it and altogether it is just 22 cm deep.

Housing material: ABSFilter sieve: Stainless steel 1.403

Mesh size 0,7 x 1,7 mm

Weight: : 2,0 kg

Model 2000700: WFC Rainwater downpipe filter

FIRST FLUSH DIVERTERSRAINMAIN

How It Works1.The falling rainwater´s energy is attenuated by baffles in the upper filter housing.

2.Rainwater is then calmed in a small sump. 3.Water then weirs over the sump lip, and is distributed evenly across the primary cascade, the first cleaning step. 4.The primary cascade filters out any large or coarse particles, such as leaves and moss.

5.Below and behind the primary cascade is a finer secondary filter. 6.Fine and coarse particles are ejected from the front of the filter. 7.Cleaned rainwater flows out of the filter outlet to a storage tank or to the point of use or disposal system.

Page 10: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S256 257

rainmainFIRST FLUSH DIVERTERSRAINMAIN

DescriptionRainwater filter for installation in rainwater tanks. Two step cleaning system. The first coarse filter mesh protects the second, finer mesh by removing larger leaves and particles.

Retro-installation of 3P Backwashing Device ZF is possible. The Rainwater Filter ZF is ideally suited for use in conjunction with a 3P Overflow Siphon Duo and the 3P Calmed Inlet.Low maintenance, depending on the contamination.Connection capacity according to DIN 1986 for roof areas up to 150 m².All connections DN 110.Height difference of 117 mm between rainwater inlet and wastewater outlet.Mesh size of filter cartridge 0,7 x 1,7 mm.

The cleaned water can be used in washing machines, toilet flushing and garden watering, in homes, in commerce, in public buildings and in industry.

Technical DataFilter according to DIN 1989-2, Typ C

Connection inlet: DN 110Outlet into tank: DN 110Outlet into sewer: DN 110

Height difference between rainwater inlet and outlet just 117 mm.

Housing material: Polyethylene

Filter insert: Stainless steel 1.4301

Weight: 1,7 kg

Model 1000592: WFC Rainwater Filter ZF

FIRST FLUSH DIVERTERSRAINMAIN

How It Works1. Rainwater is led onto the first filtration step.

2. Coarse and larger dirt particles are led away to the sewer.

3. The pre-filtered rainwater, having passed the primary filter, reaches the second and finer filter. From here finer dirt passes to waste, clean water to the tank.

4. The cleaned rainwater is led through a calmed flow inlet into the rainwater tank.

5. Due to the steep inclination of the fine filter and its smooth surface struc-ture the dirt is quickly cleaned away into the sewer

Page 11: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S258 259

rainmainFIRST FLUSH DIVERTERSRAINMAINFIRST FLUSH DIVERTERS

DescriptionRainwater filter for installation in rainwater tanks and also in the ground before the tank. Two step cleaning system, therefore high level of filtering efficiency, independent of flow rate.Due to the steep inclination of the filter cartridge the dirt is continuously cleaned away into the sewer. Frost resistant.Self cleaning. Low maintenance intervals, filter insert is easily removed for cleaning and does not have to be changed.

Optional dirt retention basket can be supplied.Connection capacity according to DIN 1986 for roof areas up to 350 m².Max. Flow Rate Sieve insert 1,5 l/sec = 5,4 m³ cleaned water per hour.Height difference between inlet and outlet just 300 mm.The cleaned water can be used in washing machines, toilet flushing and garden watering, in homes, in commerce, in public buildings and in industry.

The filter has to be cleaned depending on the contamination 1 - 2 times during the year.

Technical DataFilter according to DIN 1989-2, Typ C

Connection inlet: 2 x DN 110Outlet into tank: DN 110Outlet into sewer: DN 125

Height difference between rainwater inlet and outlet 300 mm.

Housing material: Polyethylene

Filter cartridge: Stainless steel 1.4301Mesh size: 0,65 mm

Material Cascade insert: Polyethylene

Weight: 6,2 kg

Model 1000592: VF1 Volume Filter

FIRST FLUSH DIVERTERSRAINMAIN

FIRST FLUSH DIVERTERS

How It Works1. As water arrives the level builds up and is equally distributed across the cascade.

2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.

3. Pre filtered water then flows over the secondary filter sieve (mesh size 0,65 mm). Due to the special mesh structure of the sieve, any dirt washes directly into the sewer which means the filter is self cleaning, with very low mainte-nance.

4. Cleaned water flows to the cistern.

5. Dirt goes to the sewer.

Page 12: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S260 261

rainmainFIRST FLUSH DIVERTERSRAINMAIN

Rainwater filter for larger roof areas. This Filter can be installed in a pilot shaft or in frost-protected regions directly on the wall. Normally standard concrete shafts are used (Ø 1000 mm). The filter can be delivered to the site pre-installed in the shaft.Two step cleaning system, therefore high level of filtering efficiency, independent of flow rate. Due to the steep inclination of the filter cartridge the dirt is continuously cleaned away into the sewer. The cleaned water is collected in a tank and directed into the storage.Connection capacity for roof areas up to 700 m². Because of a Bypass-Installation a bigger area can be connected.Max. Flow Rate Sieve insert 3,0/sec = 10,8 m³ cleaned water per hour.

Rainwater inlet: 2 x DN 110/ DN 150Tank inlet: 2 x DN 110/DN 150Outlet into sewer: 2 x DN 110/ DN 150

The filter has to be cleaned depending on the contamination 1 - 2 times during the year.

Technical DataRainwater inlet: 2 x DN 110/ DN 150Tank inlet: 2 x DN 110/ DN 150Outlet into sewer: 2 x DN 110/ DN 150

Height difference between inlet and a. outlet into the storage: 350 mmb. outlet into the sewer: 510 mm

Housing and cascade material: Polyethylene

Filter cartridge: Stainless steel 1.4301

Mesh size: 0,65 mm

Weight: 16 kg

Model 1000650: WFC VF1 Volume FilterDescription

FIRST FLUSH DIVERTERSRAINMAIN

How It Works1. As water arrives the level builds up and is equally distributed across the two cascades.

2. Pre cleaning through the cascades. Largest dirt particles are led across the primary filter cascades directly to the sewer.

3. Pre filtered water then flows over the secondary filter sieve (mesh size 0,65 mm). Due to the special mesh structure of the sieve, any dirt washes directly into the sewer.

4. The cleaned water is being absorbed in the middle tank and directed through one or the two connections into the storage.

5. Dirt goes to the sewer through the shaft.

Page 13: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S262 263

rainmainRAINWATER POST FILTRATIONRAINMAIN

RAINWATER POST FILTRATION (AUTOMATIC) 0.5L/S TO 1.40 L/S

ModelBWT Infinity A Automatic backwash filter Model 10194DN 32mm 1.388 L/s

Install BWT Infinity A automatic backwash filter DN 32mm electronic timer with hour-day-week-month settings depening on the quality of the water, 90 micron anti-scale screen and associated connection module with male/male threaded unions

Installation Instructions

• Isolation valves each of the installed filters• Tundish to floor-waste or stormwater• 240V 10Amp GPO within 1 meter of the installed filters above the splash line of the tundish• Install in a plant room or under all weather sun-proof, vandal-proof, well ventilated cover

DIMENSIONS

Total Height A mm 550 mm

Height B mm 315 mm

Height C mm 295 mm

Minimum Distance-pipe centre to floor

D mm 670 mm

RAINWATER POST FILTRATION (AUTOMATIC) 2.50L/S TO 3.05 L/S

ModelAutomatic filtrationBWT Infinity A 10191DN 50mm 3.05 L/a

Install BWT Infinity A automatic backwash filter DN 50mm electronic timer with hour-day-week-month module with male/male threaded unions. The filter is capable of handling a peak demand flow rate of 3.05 L/s.

Installation Instructions

• Isolation valves each side of the installed filters• Tundish to floor-waste or stormwater• 240V 10Amp GPO within 1 meter of the installed filters above the splash line of the tundish• Install in a plant room or under all weather sun-proof, vandal-proof well ventilated cover.

RAINMAINRAINWATER FINAL FILTRATION

RAINWATER FINAL FILTRATION (BAG) 0.5L/S TO 4.00 L/S & 2.50L/S TO 3.05L/S

Model

Final bag filtration 1, 5, 10, 25, 50, 100 & 200 microns Duty 0.50 L/s – 4.00 L/s For protection of the UV disinfection systems Install (2) two WFC X100B-polypropylene bag filter housings complete with legs & internal mesh baskets; 2” inlet / outlet BSP ports

Installation Instructions

• Isolation valves each of the installed bag filter housings• Pressure gauges each side of the filter housings• Floor waste in vicinity of housing with fall to drain housings during filter bag change• If available a pressure differential switch across each bag housing with voltage free contact to a BMS system to monitor pressure loss and bag blockages

Page 14: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S264 265

rainmainRAINWATER POST FILTRATIONRAINMAIN

RAINWATER POST FILTRATION (AUTOMATIC) 6.00 L/S TO 10.00 L/S

Model BWT RF Multipur A DN 80mm 10.00 L/s

Install RF Multipur A automatic backwash filter DN 65mm electronic timer with hour-day-week-monthly settings depending on the quality of the water, 90 micron anti-scale screen, pressure differential over-ride to backwash immediately in case of early blockages, pressure gauges, BMS connections for filter & power failure monitoring & associated 4 bolt Table 16 European DN 80mm flanges

Installation Instructions

• Isolation valves each side of the installed filters• Bypass valve if only 1 filter is installed• Tundish to floor-waste or stormwater• 240V 10Amp GPO within 1 meter of the installed filters above the splash line of the tundish• Install in a plant room or under all weather sun-proof, vandal-proof well ventilated cover.

RAINWATER FINAL FILTRATION (BAG) 6.00 L/S TO 10.00 L/S

Model

FINAL bag filtration 1, 5, 10, 25, 50, 100 & 200 microns

For protection of the UV disinfection systems Duty 5.00 L/s – 10.00 L/s

* Install (2) two WFC BFN-12-304-2" food quality stainless steel bag filter housings complete with legs & internal S/S meshbaskets; 2” inlet / outlet BSP ports that accept P2 size (7” OD x 323 “ long filter bags with S/S rings inserted at the top of the bag for extra strength.

* Supply only: (4) four WFC BPG-25-2SS-25 micron nominal polypropylene filter bags ( 2 are spare)

Installation Instructions

• Isolation valves each side of the installed bag filter housings• Install on a manifold in parallel• Pressure gauges each side of the filter housings• Floor waste in vicinity of housing with fall to drain housings during filter bag change• If available a pressure differential switch across each bag housing with voltage free contact to a BMS system to monitor pressure loss and bag blockages

Final Filtration

RAINMAINRAINWATER UV DISINFECTION

RAINWATER ULTRAVIOLET UV DISINFECTION 1.250 L/S TO 4.00 L/S

Model Install: (1) one BWT Bewades 100W100/11 LC 316 S/S ultra violet disinfection system 7.50M3h

Technical Data

Nominal connection width DN 50mm

Max vol. flow 400 J/m2 at T = 70% transmission 7.50Mh

Max op pressure bar 10 bar

Min/Max ambient water temp. 5/40ºC

Emitter power W 100

Power 230/50 V/Hz

Degree of safety IP 54

Inbuilt turbulators to minimise fouling of the quartz sleeve Yes

UV chamber 316 Ti S/S Yes

Ibuilt cooling fan & vent to minimise heat during summer months

Installation Instructions

• Install on a manifold in parallel if there are 2 systems• Isolation valves each side of the install UV chamber• Install a bypass valve if there is 1 system • Install 240V 10 Amp GPO within 1 metre of the systems• Fall to floor-waste in vicinity of UV chamber to drain during service• Install in plant room or under all weather, sun-proof, vandal-proof well ventilated cover.

RAINWATER ULTRAVIOLET UV DISINFECTION 2.50 L/S TO 5.55 L/S

Model Install: (1) one BWT Bewades 200W100/11 LC 316 S/S ultra violet disinfection system 10.00M3h

Technical Data

Nominal connection width DN 50mm

Max vol. flow 400 J/m2 at T100 = 70% transmission 10.00M3h

Max op pressure bar 10 bar

Min/Max ambient water temp. 5/400ºC

Emitter power W 200

Power 230/50 V/Hz

Degree of safety IP 54

Inbuilt turbulators to minimise fouling of the quartz sleeve Yes

UV chamber 316 Ti S/S Yes

Ibuilt cooling fan & vent to minimise heat during summer months

Installation Instructions

• Install on a manifold in parallel if there are two systems• Install isolation valves each side of the UV chambers• Install a bypass valve if there is only 1 system • Install 240V 10 Amp GPO within 1 metre of the systems• Fall to floor-waste in vicinity of UV chamber to drain during service• Locate UV chambers near a floor-waste to drain & clean during service• Refer to technical data for installation

Page 15: Rainmain 120612 - All Pumps Sales & Service · The rainmain controller is used in a rain water harvesting system to switch the system to mains water supply when all harvested water

RAIN

MAI

N SY

STEM

S266 267

rainmain

RAINWATER ULTRAVIOLET UV DISINFECTION 0.5L/S TO 1.40 L/S

Model Install: (1) one BWT Bewades Rainwater 80W80/11 LC 316 S/S ultra violet disinfection system

Technical Data

Nominal connection width DN 32mm

Max vol. flow 400 J/m2 at T100 = 70% transmission 4.50m3h

Max op pressure 10 bar

Min/Max ambient water temp 5/40ºC

Emitter power W 80

Power 230/50 V/Hz

Degree of safety IP 54

Inbuilt turbulators to minimise fouling of the quartz sleeve Yes

UV chamber 316 Ti S/S Yes

Ibuilt cooling fan & vent to minimise heat during summer months

Installation Instructions

• Isolation valves each of the installed filters• Tundish to floor-waste or stormwater• Tundish to floor-waste or stormwater• 240V 10Amp GPO within 1 metre of the installed filters above the splash line of the tundish• Install in a plant room or under all weather sun-proof, vandal-proof, well ventilated cover

RAINWATER UV DISINFECTIONRAINMAIN RAINMAIN

RAINWATER UV DISINFECTION

RAINWATER ULTRAVIOLET UV DISINFECTION 5.0 L/S TO 10.00 L/S

Model Install (2) Two UV-disinfection units, manufacture BWT Type Bewades 240W80/22 LC

Technical Data

Connection width 80mm

Nominal flow rate at transmission of 70%/ 10cm and UV-dose of 40 mWs/cmý m3/h 22

Nominal pressure max. bar 10

Water temperature min./max. øC 5/30

Ambient temperature min./max. øC 5/40

Radiator performance W 80

Expec. Lamp life time H 8000-10000

Power supply V/Hz 230/50

Number of radiators 3

Degree of protection IP 56

Inbuilt turbulators to minimise fouling of the quartz sleeve

Inbuilt cooling fan & vent to minimise heat during summer months

Installation Instructions

• Install on a manifold in parallel if there are 2 systems• Isolation valves each side of the install UV chamber• Install a bypass valve if there is 1 system • Install 240V 10 Amp GPO within 1 metre of the systems• Fall to floor-waste in vicinity of UV chamber to drain during service• Install in plant room or under all weather, sun-proof, vandal-proof well ventilated cover.