Radiation- and Magnet field- Tolerant Power Supply System. System Concept : Water-cooled Floating Power Supply Monitoring & remote control 19‘‘ Power Bin. Modular Floating Power Supply. 8-12 independent potential free outputs, floating Sensing of all outputs - PowerPoint PPT PresentationTRANSCRIPT
19/04/23 1
Radiation- and Magnet field- TolerantPower Supply System
System Concept :
Water-cooled Floating Power Supply
Monitoring & remote control
19‘‘ Power Bin
19/04/23 2
Modular Floating Power Supply
8-12 independent potential free outputs, floating
Sensing of all outputs
DC output power 2,2kW at 250VDC per 3U box (depends on installed modules)
19/04/23 3
Modular Floating Power Supply
CE conform EN 50 081/82 part 1
Safety in accordance with EN 60 950
Water cooled
Easy insertion / extraction locking lever and carrying handle
19/04/23 4
Modular Floating Power Supply
Power box for 6 modules, single or dual output
Floating Range >10V (min. ca. 1,5 x Uout)
Up to 100mT Magnet field tolerant
19/04/23 5
Radiation Tested Modules of PL 500
Mains 2-7V/100A +/-5V/30A +/-12V/10A +/-15V ControllerInput (2-7V) Aux-Power Board
MNE MEH MDH MDL MUH MicroModule Module Module Module Module Processor
Facility Year
A 2000 passed passed passed passed fails passed, excl. CAN
New ModuleB 2002 passed passed passed passed passed fails after 417Gy
New ModuleC 2002 fails after 4.0E+10 p/cm² passed passed passed not tested not tested
New ModuleD 2002 passed not tested not tested not tested passed fails temporary
after 3,1krad
A TCC2 722Gy 7.99E+12 n/cm²B TCC2 417Gy 7.69E+12 n/cm²C Louvain SEE 1.0E+11 p/cm²D PSI SEE 14krad
19/04/23 7
Principle of Modular Structure
Modular DesignControl
Power Module 1.2
Auxiliary Power Supply
Power Module 6.2Input: 250 VDCOutput: various Voltages, max. 200 WMonitoring & Protection
Input: 250 VDCOutput: +/-15V - 1A
Input: 250 VDCOutput: various Voltages, max. 200 WMonitoring & Protection
Power Module 2.1Power Module 1.1
Mains Input
Input: 250 VDCOutput: various Voltages, max. 200 WMonitoring & Protection
Input: 250 VDCOutput: various Voltages, max. 200 WMonitoring & Protection
Input: 250 VDC, 10 AOutput: 250 VDCFilterDC_OK - Signal
19/04/23 8
Magnetic and Radiation Tolerant Power Module
Adjustable Values on the Regulator Board :
Output Voltage
Current Limit
max. Module Voltage (OVP)
manual trimming
19/04/23 9
Modular Control Board
Basic Board with:
Clock Generation
Global Module Off if Mains Voltage too low
All Monitoring & Control Signals are fed to an (optional) plug-in monitoring board
• (Already developed except the plug in board)
19/04/23 10
Monitor and Control Board (simple)
One analog output for each voltage & current (2 * 12 lines + return)
Inhibit input for each channel (12 lines + return)
Connection to external control via 50-wire flat cable (i. g. to EMLB)
(available)
19/04/23 11
Monitoring Board (Medium Version)
Multiplexing of input / output signals (4 address lines, 1 enable line)
Voltage, Current, Temperature & Status (4 lines + return)
Inhibit input (1 line + return)
Connection to external control via 25-wire flat cable
(Ready for board design)
19/04/23 12
Monitoring Board (Complex Version)
Redundant micro controller system
Measurement of Voltage, Current, Temperature & Status
Inhibit & Switch Off of each channel possible (this feature must be activated with a jumper)
Connection to external control via 2-wire CAN-Bus
(Component evaluation and testing Stage)
19/04/23 13
Monitoring Board with ELMB integrated
connects all voltage, current, temperature and status signals to the CERN ELNB board
inhibit / switch off possible via ELNB outputs
Connection to external control via 2-wire ENLB can bus
(possible solution, still to develop)
19/04/23 14
Available modules:
Range 2-7V <30A/200W Dual Output Module
Range 5-12V<20A/200W Dual Output Module
Range 2-7V <100A/500W Single Output Module
Range 5-10V <70A/500W Single Output Module
– Voltage trimmable +/-20%, intern manually
19/04/23 15
CANbus & OPC serverworking with „Coplex Monitoring Board“
Access to all monitoring information and control function
Can handle up to 126 Power Supplies with max. 8 channels 63 Power Supplies with more than 8 channels
One Address may use for “emergency”
Indicates each faulty detail
19/04/23 16
Canbus Interface for Crate Remote Control
Wiener CANbus Interfaces can control and monitor
Power Supplies systems
voltages, currents, temperatures, failure reports
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
19/04/23 17
Canbus Interface for Crate Remote Control
CANbus Controller
Conforms CAN specification 2.0A (11-bits identifier) 9-pin male DSUB connector (CiA DS102-1
Specification) Opto-isolated transceiver , unshielded cable can be
used with at least 110 nodes for high speed (1 Mbaud) bus
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
19/04/23 18
Canbus Interface for Crate Remote Control
Wiener CANbus Interface Protocol
COB ID mapping doesn’t directly correspond to the CAL/CMS priority definition
CANOpen protocol is not supported No NMT, SDO, SYNC, TimeStamp, Nodeguard
messagesIt doesn’t conform Minimal Functionality Device
Specification (CiA 301 profile)
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
19/04/23 19
via OPC standard
CANbus Interface
PVSSII Application
OPC Client I/F
PVSSII Application
OPC Client I/FCommercial CanBus Interface PCI Cardwith Custom OPC Server
Wiener Device
Known devices only
CANBus
Wiener Device
Wiener Device
Wiener Device
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
CANbus Integration, Interface to SCADA
19/04/23 20
Custom OPC Server
Features:
Supports only one type of devices (i.E. WIENER only)
Is dedicated to one type of PCI CAN I/F card (API library) – presently Kvaser Card
Needs to be redesigned if one of above changes
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
19/04/23 21
Custom OPC Server
Architecture:
KVASER PCI/CAN driver with Application Program Interface
for C/C++
OPC Data Access Server Interfaces
Process Data Access Functionality
Configuration, Initialization
KVASER PCI/CAN API calls
OPC Toolkit
Custom software
KVASER Firmware
DCOM
CANbus
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
19/04/23 22
Functional Blocks of the OPC Server Kit
Initializer of the driver and devices
Process data access queues handling
Two separate threads: listening and transmitting (for each CAN port)
Process data to/from CAN messages mapping
ERROR (and WARNING) messages logger
Prepared by Institute of Nuclear Physics ; Cracow - POLAND
19/04/23 23
Network configuration example (variable namespace)
Prepared by Institute of Nuclear Physics ; Cracow - POLAND