RADIANT HEATING SYSTEMS
ECOFILM
an electric heating foil
Convection: Radiators, fires, heaters etc.
ECOFILM F –Floor heating foil
ECOFILM F -Radiant heat
20 º 22 º 24 º 26 º
2.5 m
2.0
1.5
1.0
0.5
0
ECOFILM C –ceiling radiant heating
The floor surface must be level and clean.
Cut a channel in the concrete for the floor probe. It should lead to where the thermostat is to be placed.
Put the floor probe into the channel and run the connection wire to the wall. Secure the probe with tape.
Concrete sub floor
Lay hardboard on top of the floor boards to achieve a smooth, clean level surface. Put the floor probe into the
channel and run the connection wire to the wall. Secure the probe with tape.
Cut a groove in the board for the floor probe.
Timber sub floor
Use Depron to insulate the floor. Secure the Depron using 2” tape.
Cut a hole in the Depron where the floor probe is to be positioned.
The ECOFILM F can now be rolled out across the floor covering the area that is to be heated.
Remember not to place the element under fixed objects in the room.
The Flexel element is joined up in parallel leading to the point where the thermostat is to be placed.
Install the thermostat making connections from the element and the floor probe.
A polythene sheet is laid over the top of the element.This can be replaced by the manufacturers recommended material if required for warranty.
The laminate floor is laid on top of the polythene.
ECOFILM C –Ceiling heating foil
Install metal joists (5) to the ceiling structure (6), lay thermal insulation min. 50mm (4), spread the heating foil ECOFILM C (3), lay PE foil as moisture stop (2), carry out
wiring , cover with plasterboard (max. 16 mm thick) (1)
ECOFILM C – ceiling heating foil
ECOFILM C - installation
ECOFILM Construction
Polyester/ Polyethylene foil (1), Copper electrodes (2), Silver coated strips (3), Carbon printed heating element (4), Polyester/ Polyethylene foil (5)
Fenix Crimping Tool
Check calibration on a regular basis
Equipment required for ceiling installation
Top View Side View Snapped together
Fenix) “t” type connector cover
AMP “Termifoil 330716” (Fenix)
Clear, 150C rated, polyester tape (Fenix)
Non – Heating Leads (Fenix)
PVC ETFE1.5 mm² single core
1.5 mm² Single core, double insulated, ETFE/ flexible PVC, Blue or black colour.
Check the roll for any damage including folds and creases. Damaged areas must be discarded
Seal both ends of element with Fenix tape
Fold AMP and closewith thumb and forefinger
Insert leads
Insert element into crimp
Make 2 diagonal applications with the flat edge of the crimping tool on the crimp.
Make application with the “W” section of the crimping tool on the cylindrical ferrule.
Equipment required for floor installation
1
2
35
4
1) Crimp connectors
2) Vulkanized tape MASTIC
3) Polyester insulation tape
4) Connection cables 1,5 mm2: black and blue colour
5) Crimping tool
1) Check the roll for any damage including folds and creases. Damaged areas must be discarded
3) Seal both ends of element with Fenix tape
4) Insert leads. Insert element into crimp. Fold AMP and close with thumb and forefinger
.
2)
5) Crimp connector must be insulated by MASTIC strip.
Introduce lower section of “t” connector cover.
Equipment required for ceiling installation
When crimp is in place introduce top section of “t” cover
Snap connector covers together. Repeat for all copper conductor end pieces.
ECOFILM Set An electric heating foil - DIY product
- an effective system for laminate and wooden floor warming and heating.
- The set contens:
•Strip of heating foil Ecofilm of 600-mm total width (heating active width getting 550 mm), of the 60W/m2 or 80W/m2 surface input, supplied in rolls of different lengths as the customer requires and in accordance with the laying plan.
•Couple of additional insulating discs (using in case of heating foil length cutting and need copper electrode strips insulation)
•Instruction manual
ECOFILM Set INSTALLATION STEPS
•The ECOFILM Set is installed directly under the laminate (floating) or timber floors in the same way as the standard ECOFILM F606 or F608 foils offered since many years.The floor structure is recommended as follows:
1 - laminate floating floor
2 - PE film 3 - ECOFILM F heating film
4 – INSULATION (Depron, Saarpor-Polyplan)
5 - baase concrete
ECOFILM Set LAY-OUT SAMPLE
ECOFILM Set INSTALLATION STEPS
1. The connection of the ECOFILM Set with connecting leads prepared in advance is just the great advantage because the installer or even the user by himself may very easily. Just the final electrical measuring and connection (interconnection of all connecting leads in the installation box and thermostat connection) shall be entrusted to a professional possessing the necessary qualification
ECOFILM Set PRODUCT RANGES
Type OUTPUT Heating foil Voltage Total Active Active area
ECOFILM Set W W/m2 strip length (m) (V) width (m) width (m) m2
ESet 60-2/66 66 60 2 230 0.60 0,55 1,1
ESet 60-3/99 99 60 3 230 0.60 0,55 1,65
ESet 60-4/132 132 60 4 230 0.60 0,55 2,2
ESet 60-5/165 165 60 5 230 0.60 0,55 2,75
ESet 60-6/198 198 60 6 230 0.60 0,55 3,3
ESet 60-8/264 264 60 8 230 0.60 0,55 4,4
ESet 60-10/330 330 60 10 230 0.60 0,55 5,5
ESet 80-2/88 88 80 2 230 0.60 0,55 1,1
ESet 80-3/132 132 80 3 230 0.60 0,55 1,65
ESet 80-4/176 176 80 4 230 0.60 0,55 2,2
ESet 80-5/220 220 80 5 230 0.60 0,55 2,75
ESet 80-6/264 264 80 6 230 0.60 0,55 3,3
ESet 80-8/352 352 80 8 230 0.60 0,55 4,4
ESet 80-10/440 440 80 10 230 0.60 0,55 5,5
ECOFILM MHF
ECOFILM MHF (Mirror Heating foil)Type Output Dimensions
W mmMHF 12 12,5 274x274MHF 25 25 274x574MHF 50 50 524x524MHF 100 100 1024x524
An electric heating foil under mirror
- an effective system for keeping the mirror completely steam-free.
- ECOFILM MHF is connected to the lighting circuit so that it is activated when the light is switched on.
- Self-adhesive side of ECOFILM MHF is placed on back of mirror after peeling of protective release paper.
Mirror WITH a heating foil ECOFILM MHF
Mirror WITHOUT a heating foil ECOFILM
MHF
ECOFILM Products ranges
ECOFILM F- heating foil for floor heatingType Output Total width Active width
W/sqm mm mm606/55 60 600 550608/55 80 600 550
615 150 600 500620 200 600 500
Note :Types F 606 and 608 for the wooden and lamiante floors – there cannot be use heating film with higher output !!!
ECOFILM C - ceiling heating foil into gypsum plastboardsType Output Total width Active width
W/sqm mm mmC 414 140 400 300C 420 200 400 300C 514 140 500 400C 520 200 500 400C 614 140 600 500C 620 200 600 500
Recommended regulation methodECOFILM C – analogue or digital room thermostat
FLASH 25614 EBERLE RTR-E 6202 EBERLE Instat 2
EBERLE Instat 6-2
ECOFILM F – analogue or digital thermostat with floor sensor
FENIX Therm 100
M&S ECO M/z(s)2EBERLE Instat 6-3
EBERLE Instat 8MICROLINE OCD 1999 H
ECOFILM advantages vs metal foilECOFILM METAL FOIL
- suits to ceiling construction (width of 40, 50 and 60 cm)
- simply cut to length according to requested dimensions
- easy electric connection (in parallel for direct return to the
room thermostat position)
- if Ecofilm will be damaged it can be simply repaired
- limited modular sizes (making stocking difficult and transport
difficults)
- individual termination into separate termination boxes
- in case of damage metal foil rerequires complete replacement
YOUR A RIGHT PARTNER IN AN ELECTRIC HEATING SYSTEMS
Contact us :
FENIX Trading s.r.o.
Slezska 2
79001 Jesenik, Czech Rep.
Tel/Fax: +420 584 495 304/303
E-mail: [email protected]
Web: www.fenixgroup.cz