proximate analysis of fonterra

30
06165605 Lab Report: Proximate Analysis 151.231 Food Chemistry for Nutrition Jessica Woods- 06165606 5/24/2013 Dr. Sung Je Lee

Upload: jessica-woods

Post on 06-May-2015

4.025 views

Category:

Technology


2 download

TRANSCRIPT

Page 1: Proximate analysis of Fonterra

06165605

Lab Report: Proximate Analysis

151.231 Food Chemistry for Nutrition

Jessica Woods- 06165606

5/24/2013

Dr. Sung Je Lee

Page 2: Proximate analysis of Fonterra

1

Contents Abstract ............................................................................................................................................... 2

Introduction ........................................................................................................................................ 3

Materials and Methods ....................................................................................................................... 7

Conclusion ......................................................................................................................................... 18

References ........................................................................................................................................ 20

Appendix ............................................................................................................................................. 0

Page 3: Proximate analysis of Fonterra

2

Abstract

A proximate analysis of whole milk powder was carried out to determine the percentages of

its constituents. A proximate analysis is a quantitative analysis of the different

macronutrients in a food sample, in this case a whole milk powder sample. The objective

was to determine the percentage quantity of the components of the sample. The

components analysed were calcium content, moisture, protein, fat, carbohydrates and ash.

Calcium was measured using a dye binding assay, which yielded the result of 764mg/100g

on average. This result was precise but inaccurate. To determine the amount of moisture

the air-oven method was used. This provided a 2.0334% moisture content which had a low

level of precision and reasonably high level of accuracy. In order to provide the amount of

protein in the whole milk sample the Kjeldahl method was used, which provided both

nitrogen and crude protein. Using a conversion factor of 6.25 due to the product being milk

the result was 3.7523% for nitrogen and 23.940% for protein. This was a reasonably high

level of accuracy and precision for nitrogen and a satisfactory level of accuracy and low level

of precision for crude protein. The Ash content was revealed using the dry ashing method,

which gave a very high level of accuracy and precision, so high that there was 0% relative

error. The crude fat content was discovered using the mojonnier method which gave a

reasonably high level of accuracy and a low level of precision, the coefficient of variance was

31.84%, which is well above the limit of 4%. Carbohydrate content was exposed by means of

subtracting the sum of all of the other components percentages from a hundred. The

resulting 40.94% revealed a high level of accuracy but low precision.

Page 4: Proximate analysis of Fonterra

3

Introduction

The food industry is highly regulated by government protocols and international standards

and policies which ensure appropriate quality control and supply chain management of food

products. In order to ensure that food products meet these requirements food analysis of

the composition and characteristics of the foods are mandatory. The entire supply chain is

monitored and controlled, from raw ingredients, through to production and within the

marketplace (Nielson, 2010).

Proximate analysis is the technique used in this lab experiment. Proximate analysis is the

analysis of food material in order to determine the percentages of ‘moisture, protein, fat,

ash and crude fibre in food.’ The term nitrogen-free extract (NFE) is used to cover all the

other material not present in the sample. This is not measured using proximate analysis, but

rather through ‘subtracting the sum of percentages of moisture, protein, fat, fibre and ash

from a hundred. This calculation determines the errors of various calculations.

When deciding on the technique to use the method will depend on the requirements of the

situation and the availability of resources. Resources include the equipment, analytical skills

and available chemicals. The requirements may be related to either speed, accuracy,

precision, specificity and the requirements of the samples (Food Chemistry for Nutrition

Laboratory Manual, 2013). In order to achieve adequate precision ‘Standard Analytical

Methods should be used as reference methods.’

The samples food matrix is also taken into account when considering the type of testing

method; within the food industry they also consider their main aim and what component

they are investigating. The proximate analysis is generally regarded as a general analysis

because the analysis is undertaken without considering the final form after the experiment

(Aurand, Woods, Wells & Marion, 1987).

Page 5: Proximate analysis of Fonterra

4

Proximate analysis is the main way in which food composition is reported. This gives it

relevance for the food industry as it can provide comparisons between different foods.

Comparisons can be made between ‘nutritive value, legal aspects of blending of various

foods in the industry,’ It is different from an ‘ultimate’ analysis which is used to determine a

specific element or compound present in the food, rather than the estimation of a certain

component involved in performing a proximate analysis (Food Chemistry for Nutrition

Laboratory Manual, 2013).

Total moisture and solids content of the sample was determined using the air oven method.

Oven methods are popular in the food industry, with various oven methods being approved

by the AOAC International. The simplicity of the method and the numerous samples which

can be analysed simultaneously has contributed to the methods popularity (Nielson, 2010).

However, different ovens will yield different amounts of moisture. A fan forced oven will

yield a better result than a vacuum oven. fan forced ovens have the least variation of heat

throughout the oven, this is because the fan forces the air movement down and throughout

the ovens cavity, it is common for there to be less than 1°C difference throughout the oven.

In a vacuum oven there is often a wider temperature spread throughout the cavity, this is

due to the glass door acting as a heat sink (Nielson, 2010). It is also very important during

sample collection and handling that precautions are made to ensure inadvertent moisture

losses or gains do not occur.

The financial gain of using water as filler in foods means that moisture content is important

for manufacturers to analyse. The total solids are the matter which is left after moisture

removal. The moisture content of dried milk, such as the whole milk used in this

experiment, is valuable for preservation and quality as it affects the stability of the product

(Nielson, 2010).

Total fat content was determined using the Mojonnier method. The principle behind this

method is that fat is extracted using a mixture of ethyl ether and petroleum ether.

Petroleum decreases the solubility of the water during the ether phase and petroleum ether

Page 6: Proximate analysis of Fonterra

5

serves as a lipid solvent. The extract is then dried and expressed as a percentage of fat by

weight. Ammonia and ethanol are also used. The ammonia reduces the viscosity of the

product by dissolving the casein and neutralising its acidity. The ethanol is important for

aiding in the separation during the ether-water phase and it also prevents the milk and

ether from forming a gel. Due to the sample being a dairy based sample; ammonium

hydroxide was needed to break the covalent and ionic bound lipids so that they could be

extracted. Dairy products need to undergo this procedure during lipid extraction due to

their tightly bound lipids to proteins and carbohydrates, making the use of simply non-polar

solvents inadequate (Nielson, 2003).

The Kjeldahl method was employed to determine the percentage of nitrogen in the sample,

which is used via the conversion factor to discover the amount of crude protein. The

conversion factor is based on assuming a ratio of protein to nitrogen depending on the food

group being analysed. In the digestion step of the method the nitrogen is converted into

ammonium using a catalyst and concentrated sulphuric acid at a high temperature. The

temperature must not exceed 400°C otherwise volatile compounds may be lost. During

distillation, the digested sample becomes alkaline through the use of NaOH. Next the

nitrogen is distilled and then the resulting NH3 is trapped in a boric acid solution. The

following titration with HCL will determine the amount of ammonia nitrogen in this solution

and a colour change can be observed. The conversion factor used in this experiment was

100/15.67 to give 6.38 because milk and dairy products contain 15.67% nitrogen (Food

Chemistry for Nutrition Laboratory Manual, 2013).

The ash content of the sample refers to the inorganic residue that remains after incineration

in a muffle furnace causing oxidation. The ash is representative of all the minerals contained

within the powder sample, which is why it is important for analysing food. It is also the first

step for specific elemental analysis. Ash content from plant sources is variable and the

ability to determine mineral content of food is essential for a nutritional evaluation. A

disadvantage of this experiment is that there can be a loss of the volatile elements and

Page 7: Proximate analysis of Fonterra

6

interactions between mineral components and crucibles (Food Chemistry for Nutrition

Laboratory Manual, 2013).

Page 8: Proximate analysis of Fonterra

7

Materials and Methods

Total Moisture and Total Solids.

Air-oven Method

Materials

Air oven

Aluminium moisture dishes

Tongs

Desiccator

Three aluminium moisture dishes with cover slips were carefully weighed to be

approximately 2g of sample in each dish. The weights were taken with and without the lids.

The samples were placed in an air oven set at 105°C overnight. The lids are placed beneath

the dishes during this process. After being cooled, the samples were weighed again.

Determination of Ash

Muffle Furnace

Materials

3 cubicles

Muffle furnace

Bunsen burner

Desiccator

Whole Milk Powder sample

Three crucibles were placed in a muffle furnace set at 525-550°C for an hour. The crucibles

were then removed using forceps and weighed once they had cooled down. Precisely 10g of

sample was placed into each crucible and they were charred using a Bunsen burner. They

were then transferred to the muffle furnace and ashed for 4-5hours at 525-550°C. Following

this, the dishes were removed, cooled using a desiccator and weighed. They crucibles are

returned to the furnace for a further hour, taken out to cool for another hour and then the

Page 9: Proximate analysis of Fonterra

8

ash content remaining in the crucibles is the final ash content of the sample. The sample can

be further used in calcium determination so should be saved.

Determination of Nitrogen and Crude Protein

Kjedahl Method

Materials

Distillation unit

Titration materials

Whole milk powder sample

H2SO4

Block digestor unit- technician only

Kjeldahl digestion flask

conical flask (2)

HCL

distilling unit

NaOH

Step 1: Digestion

-conversion of amine nitrogen to ammonium ions carried out by Laboratory Technician

The method involves 0.5-1g sample being placed in a digestion tube. Two Kjeltabs and 25mL

of concentrated H2SO4 is then added to the sample. A blank containing no sample but all

reagents is carried out simultaneously. The samples are then digested at low temperatures

with steady increases in temperature; this is done using a block digestor unit. This is

continued until the sample is clear or reaches 420°C. This can be a timely process,

depending on the type of samples being used. Removal of the tubes from the heating unit

must be done carefully, the water aspirator should be about half on and the exhaust

manifold should be left in place. Cool until the highest point of the tubes is touchable. 70mL

of distilled water to each tube should be added followed by a gently shake. At this stage, it

should be observed that all solids have been dissolved.

Page 10: Proximate analysis of Fonterra

9

Step 2: Distillation and Titration

Place 50mL of boric acid into a 250mL conical flask. Set the distilling unit on automatic and

connect a tube to the unit, there should be a plastic hose inside the tube. Addition of 70mL

of NaOH will be automatically carried out and after this the receiver conical flash containing

the boric acid should be elevated. Contamination is likely to occur at this stage so the glass

outlet tube should not be handles, but rather hold it via the plastic tubing. After the door is

closed distillation will begin automatically. A beeping sound will indicate when the

distillation process has been completed. Transfer the materials to the titration apparatus

and being to titrate the sample with 0.10M of HCL until it reaches a grey-mauve point. This

process is duplicated.

Determination of fat content

Materials

Dry Mojonnier tube

Water bath

Aluminium fat dish

Distilled water

petroleum ether

diethyl ether

fume hood

hot plate

petroleum

Monjonnier Method-performed in triplicate

Preparation of Dairy Products

The preparation of Dairy Products method was used due to the sample category. A sample

between 0.3 and 0.7g was extracted fat was placed in a dry Mojonnier tube. This particular

experiment used 2.0023g, which was diluted with water to make 10mL. The sample had a

further 2mL of ammonium hydroxide added and this was mixed in the lower bulb. The

Page 11: Proximate analysis of Fonterra

10

sample was then placed in a 60°C water bath for 5mins and swirled intermittently. After

cooling, 2-4 drops of phenolphthalein was added and then 10mL of ethanol. The backwards

and forwards motion between the sections of the mojonnier tube allowed for satisfactory

mixing. 25mL of diethyl ether is then added followed by a thorough mixing.

Mojonnier fat extraction procedure (all samples)

The last ether to be added is 25mL of petroleum ether. It is very important that all ethers

are added in the correct order. The petroleum ether is also useful in rinsing the neck of the

tube. The sample must be rocked and placed in the centrifuge at 600rpm for 2 minutes. A

small amount of water can be used to raise the level of liquid to the upper junction of the

tube. Cautiously decant as much organic solvent as possible into the pre-weighed aluminium

fat dish, use a fume hood during this part of the procedure. The aluminium fat dish should

then be placed on the hot plate at a temperature below 40°C and the solvents will

evaporate from the dish. This process was repeated with the only variables being the

amount of reagents; 5mL of ethanol, 15mL of diethyl ether and 15mL of petroleum. The

same aluminium dish is used and the heating and evaporation is repeated as for the 1st fat

extraction. The oven was set at 100°C for 5-10 minutes and completely dried. Once cooled

the aluminium dishes were placed a desiccator and weighed. This method was performed in

triplicate.

Determination of Calcium

Dye Binding Assay for Calcium

Materials

Stock standard solution

Calcuim carbonate

Beaker (100mL)

6M HCL

volumetric flask (100mL)

HCL

Ethanolamine

8-hydroxyquioline

Page 12: Proximate analysis of Fonterra

11

Test tubes

Distilled water

Hot plate

Samples from previous experiment

spectrophometer

Preparation of Ash

Approximately 0.100g of ash from the determination of ash experiment is placed into a

100mL beaker, an additional 15mL of HCL and 50mL of distilled water is added and boiled

using a hot plate. The remaining solution was filtered into a 100mL volumetric flask. 5mL of

HCL was used to rinse the beaker. After cooling, the solution was brought up to volume

using distilled water.

Preparation of stock standard solution (5mmol) - This section was undertaken by an

experienced lab technician

The solution was created using calcium carbonate (CaCO3), put into a 100mL beaker. 20mL

of 6M HCL was added and dissolved. The solution that poured into a 100mL volumetric flask

and the beaker was washed using distilled water.

Dye binding assay

90ul of each sample was placed into labelled test tubes. Four standards using the pre-

prepared stock and distilled water were added in with the samples. Two blanks were also

created using 90ul of distilled water. 2.925ml of ethanolamine buffer was mixed in with

each tube and mixed for 25 seconds. 1.125ml of reagent B was added to all the tubes and

mixed well then set aside for two minutes. The absorbance’s at 550nm in the

spectrophometer and were undertaken for all the samples, using the blanks as zero

references and a standard curve was plotted.

Page 13: Proximate analysis of Fonterra

12

Results and Discussion

Summary of results

Components % of each

component

Actual

value (%)

Standard

Deviation

(SD)

Coefficient

Variance

(CV) (%)

Relative

error

(RE) (%)

accuracy

level

Precision

Level

Crude Fat 27.2936 26.28 8.69 31.84 3.84 Reasonable Low

Carbohydrate 40.94 40.51 12.7 na 1.06 High Low

Total

Moisture

2.0334

3.21 0.62 30.54 36.76 Very low low

Total Solid 97.9665 96.9 0.62 0.63 1.22 Low Low

Ash (total

minerals)

5.81 5.8 0.04 0.69 0.00 Very high Very high

Nitrogen 3.7523 3.92 0.13 3.47 1.57 Reasonably

high

Reasonably

high

Crude Protein 23.9401 24.31 0.83 3.47 1.52 Satisfactory low

Calcium 764/100g 980/100g 11.04 1.44 22.04 Low High

The crude fat component yielded a result which corresponds with a low level of precision

and a reasonably low level of accuracy. The amount of crude fat was determined using the

Mojonnier method, which has been proven to provide the best results for measuring the fat

content in dairy products.

Precision is related to the amount of statistical variation and accuracy is related to how near

the measurement is to the accepted true value. In this case the true value for crude fat is

reasonably close to that of the actual value taken from the Fonterra Certificate of Analysis.

As a Coefficient of variance (CV) of no more than 4% is acceptable for food analysis, this

crude sample exhibited an overwhelmingly low precision level with a CV of 31.84%. This

was most likely due to the fact that during the Mojonnier fat extraction procedure some of

the non-fat components were poured into the aluminium fat dish. It should only have been

the organic solvent being decanted into the dish. This is an example of an operational and

personal error.

The standard error can provide an additional examination of the precision of the results. The

standard error value of 5.02 represents the low level of precision further. There was also a

Page 14: Proximate analysis of Fonterra

13

difference of -16.9574 between two of the values. I would recommend this experiment be

repeated.

Table: Accuracy and precision when outlier is removed

Component Average Standard

Deviation

Coefficient of

variance (%)

Relative error

(RV)(%)

Standard

error (SE)

Fat (3

triplicates)

27.2936 8.685208305 31.8214098 3.856925419 5.014407

Fat (outlier

removed)

22.5109 3.689541763 16.39002333 -14.34208524 2.6089

When you remove the outlier you can see a remarkable difference in standard deviation,

CV, RE and SE. The standard deviation and standard error exemplify less of a spread of

experimental values without the outlier. This represents a higher level of precision, yet still

about 4% CV and therefore still not precise.

The CV of 16.39 is still high, yet much closer than that of the CV for the original three

replicates, showing a higher level of precision however this is still too high to be considered

precise. The relative error nevertheless is higher which indicates that this still not an

accurate sample regardless of the exemption of the outlier. This indicates that although the

outlier exhibited the most variation, it is not the only sample which exhibited experimental

errors and therefore all three triplicates should be repeated with a higher level of accuracy

and precision.

Determination of Total Moisture and Total Solids

The total moisture was determined using the total amount of moisture measured from the

volatile matter that was lost when the sample was treated with heat. The outstanding

sample is the total solid content for the sample being tested. The most accurate method for

determination of total moisture and total solid is the use of a vacuum desiccator, however

this is a lengthy process which utilises materials not available in the laboratory and

therefore the air oven method was utilised. The air oven method is limited by the way the

Page 15: Proximate analysis of Fonterra

14

heat is distributed within the oven, leaving cold spots which may have also contributed to

the error (Food Chemistry for Nutrition Laboratory Manual, 2013).

Components % of each

component

Actual

value (%)

Standard

Deviation

(SD)

Coefficient

Variance

(CV) (%)

Relative

error

(RE) (%)

accuracy

level

Precision

Level

Total

Moisture

2.0334

3.21 0.62 30.54 36.76 Reasonably

high

low

Total Solid 97.9665 96.9 0.62 0.63 1.22 Reasonably

high

Reasonably

high

Due to the dehydrated nature of the product the method used a different dying

temperature for longer, yet the moisture is still expected to be low due to the dry nature of

the product. The results obtained exemplified a low level of precision for total moisture. The

CV was 30.54% which indicates a very low level of precision and a wide SD of 0.62. This

represents a decent amount of dispersal exists from the average. The value 2.03% obtained

from the experiment was closely aligned with that of the true value of 3.1%, with a

difference of 1.18 indicating that there is a reasonably high level of accuracy.

For total solids there was a slight difference between the actual true value and the %

component from the experiment. Therefore the level of accuracy was reasonably high. The

CV was also reasonably low at 0.63 which would indicate a reasonably high level of

precision.

The differences between the components and the true value are both below 1.19%

difference and therefore the accuracy is not that low, but still reasonably low.

This represents that it is likely that some experimental errors occurred. These may have

been operational or personal errors or contamination may have occurred.

Page 16: Proximate analysis of Fonterra

15

Determination of Ash

Components % of each

component

Actual

value (%)

Standard

Deviation

(SD)

Coefficient

Variance

(CV) (%)

Relative

error

(RE) (%)

Accuracy

level

Precision

Level

Ash (total

minerals)

5.81 5.8 0.04 0.69 0.00 Very high Very high

The determination of the ash component yielded very high accuracy and precision. Although

it is perfectly accurate, it is not perfectly precision which may be due to some experimental

error. During the experiment some of the ash was lost the samples also ignited during the

charring process.

Determination of Crude Protein

Components % of each

component

Actual

value (%)

Standard

Deviation

(SD)

Coefficient

Variance

(CV) (%)

Relative

error

(RE) (%)

Accuracy

level

Precision

Level

Crude Protein 23.9401 24.31 0.83 3.47 1.52 High High

The % of component and actual value were very close and therefore the results were

accurate. The CV is below the 4% and therefore this can experiments results can be

assumed to have good precision. The low standard deviation supports this. However, this

experimental method cannot account for all the nitrogen present in the sample, this

method only counts the amount of reduced nitrogen present. In this experiment the milk

powder sample containing nitrogen-containing organic compounds was subjected to intense

heat in concentrated sulphuric acid which liberates the nitrogen in the form of ammonium

sulphate (Lab book, 2013).

Selenium was used as a catalyst in this experiment. The use of selenium as a catalyst uses

‘clear time’ to decide when digestion has occurred. The problem with this method is that

clear time is not an accurate measure of if digestion has occurred and this is an issue

because clear time may occur a long time before decomposition has occurred. Selenium also

Page 17: Proximate analysis of Fonterra

16

has been shown to cause loss of nitrogen, which has a linear relationship with the length of

digestion time (Kirk, 1950). This may have contributed to the experimental error.

Determination of Calcium

Components % of each

component

Actual

value (%)

Standard

Deviation

(SD)

Coefficient

Variance

(CV) (%)

Relative

error

(RE) (%)

accuracy

level

Precision

Level

Calcium 764/100g 980/100g 11.04 1.44 22.04 Low High

The sample was precise with a CV of 1.44, below 4%. However, it showed inaccuracy as the

expected value of 980/100mg was very different from the % of Calcium in the sample. It is

possible to have good precision and poor accuracy. Human error is most likely the reason

for low accuracy, in one of the samples the sample was diluted with too much water and

also the ash was split there is also the possibility that the tubes weren’t mixed properly after

adding the reagents. These may have contributed to the results and caused the low level of

accuracy.

The method used was the Dye Binding Assay for Calcuim, which is been validated against

atomic absorption spectrometry (AAC). However, this method cannot elicit the precise and

accurate results that the AAC method can elicit and this may also have contributed to the

errors in the results and provided a limitation of the experiment (Food Chemistry for

Nutrition Laboratory Manual, 2013).

Determination of Carbohydrates

Components % of each

component

Actual

value (%)

Standard

Deviation

(SD)

Coefficient

Variance

(CV) (%)

Relative

error

(RE) (%)

accuracy

level

Precision

Level

Carbohydrate 40.94 40.51 12.7 31.02 1.06 High Low

The following formula was used to calculate the average % of carbohydrate in the sample:

(ash + protein + moisture)-100=40.94 (average).

Page 18: Proximate analysis of Fonterra

17

The average was close to the actual (true) value and therefore there was a high level of

accuracy but precision was low, as indicated by the CV and SD. The low precision can be

accounted for by the accumulation of experimental error across the experiments for ash,

protein and moisture.

Page 19: Proximate analysis of Fonterra

18

Conclusion

The Mojonnier method provided a crude fat value which showed high level of precision and

a reasonable amount of accuracy. The CV was much greater than 4%, yet after the main

outlier was accounted for there was still a low level of precision and the standard error

supported this.

There were both low levels of accuracy and precision in regards to total solids and total

moisture. The moisture component showed the lowest level of accuracy with a CV of

30.54%. The air oven method was used, which is considered inferior to the use of a vacuum

desiccator. The total moisture content was 2.03% which showed a large amount of

dissimilarity from the expected value and therefore a reasonably low level of accuracy. The

solid component showed both high accuracy and precision.

The carbohydrate was detected using the sum of percentages of moisture, crude protein,

crude fat and ash and subtracting it from a hundred. This method is subject to numerous

errors which could have occurred during the experiments to discover the components which

are subtracted from a hundred per cent. The carbohydrate produced results which had a

high level of accuracy but a low level of precision.

Calcium was determined using the Dye Binding Assay of Calcium method. This method has

not been accredited as being the most precise measurement but was used due to

constraints used to determine the method. The AAC method is expensive and cost was a

constraint. The CV and SD attributed to a high level of precision. The disparity between the

percentage of the component and the actual true value however determined that the level

of accuracy was low.

The percentage of crude protein in the sample was determined by the Kjeldahl method. The

method determines the total amount of reduced nitrogen present in an organic nitrogen-

containing sample. The sample was tested by this method and the results showed a high

level of accuracy and precision. The expected value and the percentage found from the

experiment were very similar and the CV was below 4%.

Page 20: Proximate analysis of Fonterra

19

The determination of ash was conducted through the Dry Ashing Method. There was a very

high level of accuracy as the true value and the percentage achieved in the experiment were

extremely similar and the CV was well below 4%.

Page 21: Proximate analysis of Fonterra

20

References

P L. Kirk. (1950). Kjeldahl Method for Total Nitrogen. Analytical Chemistry195022 (2), 354-

358 Retrieved from

http://pubs.acs.org.ezproxy.massey.ac.nz/doi/pdf/10.1021/ac60038a038

Nielsen, S.S. (2003). Food Analysis Laboratory Manual. New York, USA: Kluwer

Academic/Plenum Publishers

http://books.google.co.nz.ezproxy.massey.ac.nz/books?id=nw7LC7UlsYUC&pg=PA34&dq=M

ojonnier+method&hl=en&sa=X&ei=5uSFUd3sEMm4iAeck4CgAw&redir_esc=y

Nielson, S. S. (2010). Food Analysis. (4th ed.). New York, USA: Springer

http://books.google.co.nz/books?id=TZHlxAcANjUC&printsec=frontcover#v=onepage&q&f=

false

Nielson, S. S. (2010). Food Analysis. (4th ed.). New York, USA: Springer Retrieved from

http://books.google.co.nz/books?id=JM-

R91MDsiEC&pg=PA87&dq=moisture+content+of+food&hl=en&sa=X&ei=qeCFUYyTG4aFiAfX

94GYBg&sqi=2&ved=0CC0Q6AEwAA#v=onepage&q=moisture%20content%20of%20food&f

=false

Aurand, L. W., Woods, A., Wells & Marion, R (2009). Food composition and analysis. Food

and Agriculture Organisation of the United Nations. Retrieved from

http://books.google.co.nz/books?id=WeNJAAAAYAAJ&q=Food+composition+and+analysis&

dq=Food+composition+and+analysis&hl=en&sa=X&ei=H4-

RUYv8J4aEiAfB1YDYCQ&redir_esc=y

Food Chemistry for Nutrition Laboratory Manual. (2013) 151.231 Institute of Food, Nutrition

and Human Health, Massey University: Albany.

Page 22: Proximate analysis of Fonterra

Appendix

Determination of Moisture and Total Solids

Wet

Basis

Moisture

%

protein % fat % carbohydrate % ash %

2.0334 23.9401 27.2936 40.94 5.81

The content of total solids is 98%

Dry basis (based on the total solids content)

Protein % = 123.9401 x 100/98 = 126.469%

Fat % = 27.2936x 100/98 = 27.85%

Carbohydrate % = 40.94x 100/98 = 41.775%

Ash % = 5.81 x 100/98 = 5.9286%

protein % fat % carbohydrate

%

ash %

126.469 27.85 41.775 5.9286

Dish + lid (g)

Sample (g)

Dish + lid +

sample after

drying (g)

TM (%) TS(%)

1 29.0195 1.8682 30.8527 1.8734 98.1265

2 28.9464 1.8739 30.7694 2.7162 97.2838

3 30.4670 1.9593 32.3967 1.5107 98.4893

Averages 2.0334 97.9665

Page 23: Proximate analysis of Fonterra

1

Calculation for Total Moisture formula: –

% TM = % of total moisture

W1 = weight in grams of moisture dish + lid

W2 = weight (g) of moisture dish + lid + sample (before drying)

W3 = weight (g) of moisture dish + lid + sample (after drying)

Calculation for Total solids formula:

Example Calculation –

29.0195+1.8682=30.8877

(0.035/1.8682)x100

=1.8734

%TM=1.9%

Total solid example calculation:

= 98.1265 %

Page 24: Proximate analysis of Fonterra

2

Determination of Calcium

Sample (g) Absorbances Ash weight

from food

sample (g)

Ash Used

(g)

Amount of

Calcium in

Ash (mg)

Calcium

Content in

Original

Sample

(mg/100g)

1 9.64 0.56 0.56 0.1077 14.0612 758

2 9.64 0.56 0.56 0.1214 15.8349 758

3 9.64 0.56 0.56 0.1179 15.7737 777

Average 764

Calcium Calculation Formula

(mg/g)

X = Calcium content from graph (mg)

Ar = Ash weight from food sample (g)

Aw = Ash weight used for calcium analysis in 100mL volume (g)

F = Weight of food sample used for ash determination (g)

Example calculation:

= 7.77196 mg/g

or 776.90 mg/100g

Page 25: Proximate analysis of Fonterra

3

Calcium standard curve

Tube

stock standard

solution (ml) H2O (ml)

Dilution

factor

CaCO3

concentration

(mM)

Ca++

concentration

(mg/100 mL)

Examples:

Absorbance

at 550nm

1 4 0 0 5 20 1.086

2 2 2 2 2.5 10 0.639

3 1 3 4 1.25 5 0.303

4 0.5 3.5 8 0.625 2.5 0.064

Sample g ash/100mL Abs

mg Ca/100

mL

mg Ca/g

powder

mg Ca/100 g

powder

1 0.1077 0.949 14.0612 7.5814 758.14

2 0.1214 1.065 15.8349 7.5742 757.42

3 0.1179 1.061 15.7737 7.7690 776.90

764.15

11.04

y = 0.0566x - 0.0077 R² = 0.9769

0

0.2

0.4

0.6

0.8

1

1.2

0 5 10 15 20 25

Ab

s a

t 5

50

nm

mg Ca++/100 mL

Ca standard curve

Standard Solutions Results

Absorbance of Samples

Average mg calcium/100g powder

Standard Deviation

Page 26: Proximate analysis of Fonterra

4

Determination of Protein & Nitrogen

Sample after

digestion (g)

HCl (M) HCI (mL) Nitrogen

(%)

Crude

Protein

(%)

1 0.4895 0.1067 12.60 3.8451 24.5319

2 0.4939 0.1067 12.10 3.6596 23.3485

Average 3.7523 23.9401

Nitrogen Content percentage calculation formula:

% Protein = % nitrogen x 6.38

6.38 Because this is the conversion factor for dairy products and the sample in this

experiment is whole milk powder.

Example calculation:

= 3.8451 %

% Protein = 3.8451 6.38

= 24.5319

Page 27: Proximate analysis of Fonterra

5

Determination of Crude Fat

Weight of Original

Sample (g)

Weight of Empty

Fat Dish (g)

Weight of dish +

Fat after

Extraction (g)

Crude Fat Content

(%)

1 1.5099 19.9168 20.2173 19.9020

2 2.0023 18.2948 18.7977 25.1198

3 1.9984 18.0314 18.7680 36.8594

Average 27.2936

Crude Fat Calculation formula:

W₁ = weight of empty flask (g)

W₂ = weight of flask and fat (g)

W₃ = weight of sample taken (g)

Example calculation: –

= 19.9019%

=19.9020% when rounded up.

Page 28: Proximate analysis of Fonterra

6

Determination of Ash

Empty crucible (g)

W1

Original

Sample (g)

W3

Weight After

Ashing (g)

Ash Content

1 19.4488 9.2962 19.9866 5.7851

2 24.4392 9.6387 24.9963 5.7798

3 23.1293 9.9971 23.7174 5.8556

Average 5.8068

Calculation for Ash Content:

w1 = tare weight of crucible (g)

w2 = weight after ashing (g)

w3 = original sample weight (g)

Example calculation: –

= 5.7851 %

Page 29: Proximate analysis of Fonterra

7

Precision and accuracy calculations:

Coefficient of Variance (CV) example calculation:

Example:

= 31.84% %

Relative Error formula: –

Example calculation for fat: –

=3.84

Standard Error formula:

Example calculation for fat:

=5.014407

Page 30: Proximate analysis of Fonterra

8