preci-clix axial preci-clix radicular...

2
ENGLISH PRECI-CLIX RADICULAR WWW.CKPL.EU AXIAL ATTACHMENTS CEKA AXIAL PRECI-CLIX AXIAL PRECI-CLIX RADICULAR PRECI-BALL EXTRACORONAL ATTACHMENTS CEKA EXTRACORONAL PRECI-VERTIX PRECI-CLIX EXTRACORONAL PRECI-SAGIX PROFILE ATTACHMENTS PRECI-BAR PRECI-HORIX PRECI-CLIP DIGITAL LIBRARIES SPECIALTIES PRECI-POST CEKA SOL CEKA SITE CCC-BOND CEKA Multi - CEKA Multi O PERMA-RET PRECI-SEP PLASTICWAX EXPANDO MEASURING GAUGE SIDE EFFECTS, WARNINGS AND PRECAUTIONS The attachments are intended for single use. The products are non-sterile. There is a risk of poor fit when patient conditions change. Bacterial adhesion can be avoided by applying hygiene measures. Inappropriate use or bad manufacturing can lead to premature wear of the attachments. The functionality of the attachments will be adversely affected by traumas such as grinding and bruxism. For the purpose of traceability we advise you to record the lot number of the applied products in the patient file. Do not heat products containing titanium. Do not use products containing nickel in case of nickel allergy. The accessories RE H 79 and H 35 must be used outside the mouth. WWW.CKPL.EU ALPHADENT NV Mannebeekstraat 33, 8790 Waregem, Belgium T +32 56 629 531 E [email protected] 0197 Prospectus no 274.EN-ed.H © Copyright ALPHADENT NV 02/2020 BTW BE 0414.789.321 RPR Kortrijk AXIAL ATTACHMENTS # 1231 # 1231B 6 PCS 50 PCS yellow normal retention # 1232 # 1232B 6 PCS 50 PCS white reduced retention # 1233 # 1233B 6 PCS 50 PCS red increased retention # 1234 2 + 2 + 2 PCS combination package # 1235 # 1235B 6 PCS 50 PCS PRECI-CLIX DENTIST KIT # 1299 2 x 1291 radicular PRECI-CLIX RTI ball attachment 1 x 1226 set of 3 reamers 1 x 1222 insertion tool 1 x IMP-XS-042 screwdriver 1 x RE H 2 impression tool (2 pcs) 1 x RE H 14 model analogue (2 pcs) 1 x 1234 replacement females (3 x 2 pcs) PRECI-CLIX RTI # 1291 Female housing for incorporation into acrylic resin. Cementable titanium post with removable titanium male. 1 x 1235 female housing 1 x 1231 yellow plastic female 1 x 1206 C removable titanium male 1 x 1291 C titanium post 1 x 1251 B elastic space maintainer 1 x RA 0055 large tinfoil space maintainer (for lab use only) PRECI-CLIX HOUSING Female housing in an anodized titanium alloy for fixation in acrylic resin dentures. Do not heat. Height: 2.65 mm - ø 4 mm PRECI-CLIX FEMALE Polyacetal. Height: 2.65 mm - ø 3.55 mm # 1206 C 1 PC PRECI-CLIX MALE Removable male in titanium alloy. Do not heat. Height: 3.05 mm - ø 2.25 mm - Internal hex: 0.9 mm PRECI-CLIX POST Cementable post in titanium alloy. Do not heat. Post length: 7 mm - ø 1.35 mm - ø base: 3.4 mm - Threads: M2 # 1291 C 1 PC

Upload: others

Post on 29-Jul-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PRECI-CLIX AXIAL PRECI-CLIX RADICULAR AXIALceka-preciline.com/doc/pdf/Brochures/PRECI-CLIX_RAD_274_EN.pdf · the analogue to the laboratory. Assemble the impression tool and model

ENGLISHPRECI-CLIX RADICULAR

WWW.CKPL.EU

AXIAL ATTACHMENTSCEKA AXIALPRECI-CLIX AXIALPRECI-CLIX RADICULARPRECI-BALL

EXTRACORONAL ATTACHMENTSCEKA EXTRACORONALPRECI-VERTIXPRECI-CLIX EXTRACORONALPRECI-SAGIX

PROFILE ATTACHMENTS PRECI-BARPRECI-HORIX

PRECI-CLIP

DIGITALLIBRARIES

SPECIALTIESPRECI-POSTCEKA SOLCEKA SITECCC-BONDCEKA Multi - CEKA Multi OPERMA-RETPRECI-SEPPLASTICWAXEXPANDOMEASURING GAUGE

SIDE EFFECTS, WARNINGS AND PRECAUTIONS • The attachments are intended for single use. • The products are non-sterile. • There is a risk of poor fit when patient conditions change. • Bacterial adhesion can be avoided by applying hygiene measures. • Inappropriate use or bad manufacturing can lead to premature wear

of the attachments. • The functionality of the attachments will be adversely affected by

traumas such as grinding and bruxism.• For the purpose of traceability we advise you to record the lot number

of the applied products in the patient file.• Do not heat products containing titanium.

Do not use products containing nickel in case of nickel allergy. The accessories RE H 79 and H 35 must be used outside the mouth.

WWW.CKPL.EU

ALPHADENT NV Mannebeekstraat 33, 8790 Waregem, BelgiumT +32 56 629 531 E [email protected]

0197Prospectus no 274.EN-ed.H© Copyright ALPHADENT NV 02/2020BTW BE 0414.789.321 RPR Kortrijk

AXIAL ATTACHMENTS

# 1231 # 1231B

6 pcs 50 pcs

yellow normalretention

# 1232 # 1232B

6 pcs 50 pcs

white reducedretention

# 1233 # 1233B

6 pcs 50 pcs

red increasedretention

# 1234 2 + 2 + 2 pcscombination

package

# 1235# 1235B

6 pcs 50 pcs

PRECI-CLIX DENTIST KIT # 12992 x 1291 radicular PRECI-CLIX RTI ball attachment1 x 1226 set of 3 reamers1 x 1222 insertion tool1 x IMP-XS-042 screwdriver1 x RE H 2 impression tool (2 pcs)1 x RE H 14 model analogue (2 pcs)1 x 1234 replacement females (3 x 2 pcs)

PRECI-CLIX RTI # 1291Female housing for incorporation into acrylic resin. Cementable titanium post with removable titanium male.1 x 1235 female housing1 x 1231 yellow plastic female1 x 1206 C removable titanium male1 x 1291 C titanium post1 x 1251 B elastic space maintainer1 x RA 0055 large tinfoil space maintainer (for lab use only)

PRECI-CLIX HOUSINGFemale housing in an anodized titanium alloy for fixation in acrylic resin dentures. Do not heat. Height: 2.65 mm - ø 4 mm

PRECI-CLIX FEMALEPolyacetal. Height: 2.65 mm - ø 3.55 mm

# 1206 C 1 pc

PRECI-CLIX MALERemovable male in titanium alloy. Do not heat. Height: 3.05 mm - ø 2.25 mm - Internal hex: 0.9 mm

PRECI-CLIX POSTCementable post in titanium alloy. Do not heat. Post length: 7 mm - ø 1.35 mm - ø base: 3.4 mm - Threads: M2

# 1291 C 1 pc

Page 2: PRECI-CLIX AXIAL PRECI-CLIX RADICULAR AXIALceka-preciline.com/doc/pdf/Brochures/PRECI-CLIX_RAD_274_EN.pdf · the analogue to the laboratory. Assemble the impression tool and model

PRECI-CLIX RADICULAR

Prepare the root canal with the penetration burr and use the diamond burr to prepare the base of the PRECI-CLIX post. Use the reamer to prepare for the diameter of the post.

3 Patient comfort PRECI-CLIX RADICULAR provides a solution for a few weak remaining roots.

3 Easy and economical Easy incorporation procedures for the dentist in one single appointment; more economical than conventional ball attachments

3 Easy servicing Replaceable male and plastic females in three different retention levels

FOR DIRECT CHAIRSIDE PLACEMENT

PRECI-CLIX RADICULAR is placed by the dentist in one single appointment. The patient receives secure retention and stability for their overdenture.The titanium male and plastic females are easilyreplaceable. The attachment audibly clicks to placeto provide patient security.

The dentist has the option to incorporate the male in the remaining root and to incorporate the female in the denture at chairside or have the laboratory process the female into the prosthesis.

INCORPORATING PRECI-CLIX ATTACHMENTS

Thread the black impression tool into the post. Check the fit and cement the post. This tool is useful for cementation and protects the threads.

Take impression with the black impression tool and send it together with the analogue to the laboratory.

Assemble the impression tool and model analogue into the impression and pour a model in stone.

Thread the male into the analogue using the screwdriver.

Place the housing on a flat surface. Place the yellow plastic female over the insertion tool and press it into the housing.

Place the black space maintainer over the male. Place the female over the male. Block out any undercuts. The root surface can be relieved with the supplied tinfoil space maintainer.

Polymerize the prosthesis over the females.

ServicingUse a hot or sharp instrument to remove a plastic female. Place a new female over the insertion tool and press it into the housing. Yellow females have normal retention. White females have reduced retention. Red females have increased retention.

Use the hexagonal screwdriver (# IMP-XS-042) to fix the male in the post. This will guarantee easy replacement in the future, if necessary.