Practical Guide To Electrical Wiring, Inspection, Troubleshooting And Repairing INTRODUCTION TO ELECTRICAL WIRING REGULATIONS • Electricity Supply Act 1990, Electricity Supply Regulations and Electrical Wiring System Regulations BS 7671:2008; • Scope, object and fundamental principles of Act and Regulations; • Terminology and definitions; • IEE On-Site Guide; • Assessment of general characteristics; • Overcurrent protection of live conductors; • Sizing of live conductors; • Protection against electric shock; • Earthing and bonding practice; • Protection against thermal effects and voltage disturbances; • Isolation and switching; • Selection and erection of equipment; • Special installations or locations; INSPECTION AND TESTING OF ELECTRICAL WIRING • Inspection • Testing in compliance with BS 7671:2008 • Certification and reporting TROUBLESHOOTING AND REPAIRING • Troubleshooting and Repairing Systematic Procedures • Troubleshooting Equipments/Tools HANDS ON SESSION ON ELECTRICAL WIRING • Site Visit to Electrical Switch room • Electrical Wiring on Electrical Starters for Motors • Troubleshooting of Electrical Starters/Motors Course Content Trainer Ir. Harapajan Singh holds a Master of Engineering with Distinction (Electrical) from the University of Nottingham United Kingdom, Professional Examination of the Council of Engineering Institutions (Engineering Council), UK in Electrical and Electronic Engineering, a Diploma in Engineering (Electrical) from University Technology Malaysia and a Certificate in Engineering (Electrical) from Polytechnic Ungku Omar Ipoh. Ir. Harapajan has over 34 years of lecturing experience in engineering fields. He was the Technical Lecturer & Head of Electrical Power Unit, Department of Electrical Engineering with Polytechnic Ungku Omar Ipoh, lecturing in Electrical Machines, Power Electronic & Electrical Installation to Certificate and Diploma students in the department. He was a part-time Lecturer with Universiti Sains Malaysia lecturing in Electrical Technology & Power Electronics and he also supervised projects of power- based design by students. In the past, he has served as the Head of Electrical Department with Polytechnic Seberang Perai, Penang and as the Principal of the Kepala Batas Community College, Penang. Currently, he is the Head of Electrical Safety Department, Universiti Teknologi Mara (UiTM), Penang. October 9 & 10, 2013 Wednesday & Thursday 8:45 am - 5:00 pm @ FMM Institute, Perak OBJECTIVES Upon completion of this course, participants will be able to : • recognize the electrical wiring system regulations • design basic electrical wiring system for electrical equipments in building • select effective protective equipments and suitable cables for electrical machinery and equipment • systematic inspection, testing and reporting of completed building wiring system WHO SHOULD ATTEND Employees working with electrical equipment, Technicians, Chargeman, Safety Committee Members in Industries Registration: Upon Faxing / Mailing the completed Registration Form to FMM Institute, Perak, you are deemed to have read and accepted the terms and conditions. The course would also be deemed as confirmed unless informed otherwise. Will be based on First-Come-First-Served basis. Payment: Cheques made in favour of FMM INSTITUTE should be forwarded to FMM Institute Perak. For SBL Scheme, an Attendance of 100% is a MUST, in any case, employers will be billed in full. Cancellation: Must be in Writing with Reasons. 7 days before the course ~ No Payment Charged 3-6 days before the course ~ 50% Payment Charged < 3 days before the course ~ Full Payment Charged Participants who did not turn-up will be charged full payment. Replacements can be accepted at no additional cost. Disclaimer: The FMM Institute reserves the right to change the facilitator, date and to vary / cancel the course should unavoidable circumstances arise. All efforts will be taken to inform participants of the changes. Submitted by: (Please attach a separate list if space is insufficient.) Enclosed cheque / bank draft No. ______________________ for RM _______________ being payment for _______ participant(s) made in favour of the ‘FMM INSTITUTE’ . Name: Designation: Company: Tel: Fax: Email: Address: FMM Membership No: MyCoID: Dear Sir / Madam Please register the following participant(s) for the above programme: Name Designation I.C. No. 1. 2. 3. 4. Also available as an In-House Course REGISTRATION FORM PRACTICAL GUIDE TO ELECTRICAL WIRING, INSPECTION, TROUBLESHOOTING AND REPAIRING Closing date: October 2, 2013 Medium of Instruction: English CPD: 14 hours COURSE FEE (Fees include Course Materials, Refreshment, Lunch and Certificate of Attendance) FMM Members RM 500.00 per pax Others RM 600.00 per pax SBL Scheme MAINTENANCE / TECHNICAL category ADMINISTRATIVE DETAILS FMM INSTITUTE PERAK (Centre for Professional Development) Attn : Puan Eda / Ms Harvindar / Ms Nicole) No. 1, Lorong Raja DiHilir, Off Jalan Raja DiHilir, 30350 Ipoh, Perak. Fax. No. : (05) 548 8221 & (05) 548 8331 • Tel. No. : (05) 548 8660 Email : [email protected] (475427-W)

Upload: phungtuong

Post on 29-Jul-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Practical guide to Electrical Wiring, inspection ... Guide.pdf · Practical guide to Electrical Wiring, inspection, troubleshooting And repairing introdUCtion to eleCtriCal Wiring

Practical guide to Electrical Wiring, inspection, troubleshooting And repairingintrodUCtion to eleCtriCal Wiring regUlations•ElectricitySupply

Act1990,ElectricitySupplyRegulationsandElectricalWiringSystemRegulationsBS7671:2008;

•Scope,objectandfundamentalprinciplesofActandRegulations;

•Terminologyanddefinitions;

•IEEOn-SiteGuide;•Assessmentofgeneral

characteristics;•Overcurrentprotection

ofliveconductors;•Sizingofliveconductors;•Protectionagainst

electricshock;•Earthingandbonding

practice;•Protectionagainst

thermaleffectsandvoltagedisturbances;

•Isolationandswitching;

•Selectionanderectionofequipment;

•Specialinstallationsorlocations;

insPeCtion and testing of eleCtriCal Wiring•Inspection•Testingincompliance

withBS7671:2008•Certificationand

reportingtroUbleshooting and rePairing •Troubleshootingand

RepairingSystematicProcedures

•TroubleshootingEquipments/Tools

hands on session on eleCtriCal Wiring•SiteVisittoElectrical

Switchroom•ElectricalWiringon

ElectricalStartersforMotors

•TroubleshootingofElectricalStarters/Motors

Course Content trainer ir. harapajan singhholdsaMasterofEngineeringwithDistinction(Electrical)fromtheUniversityofNottinghamUnitedKingdom, Professional Examination oftheCouncilofEngineering Institutions(Engineering Council), UK in ElectricalandElectronicEngineering,aDiplomainEngineering(Electrical)fromUniversityTechnologyMalaysiaandaCertificateinEngineering(Electrical)fromPolytechnicUngkuOmarIpoh. Ir. Harapajan has over 34 years oflecturing experience in engineeringfields. He was the Technical Lecturer& Head of Electrical Power Unit,Department of Electrical Engineeringwith Polytechnic Ungku Omar Ipoh,lecturing inElectricalMachines,PowerElectronic & Electrical Installation toCertificateandDiplomastudentsinthedepartment.Hewasapart-timeLecturerwithUniversitiSainsMalaysialecturinginElectricalTechnology&PowerElectronicsandhealsosupervisedprojectsofpower-baseddesignbystudents. In thepast,hehasservedastheHeadofElectricalDepartmentwithPolytechnicSeberangPerai, Penang and as the Principal ofthe Kepala Batas Community College,Penang. Currently, he is the Head ofElectricalSafetyDepartment,UniversitiTeknologiMara(UiTM),Penang.

October 9 & 10, 2013Wednesday &

thursday8:45 am - 5:00 pm

@ fMM institute, Perak

objeCtivesUponcompletionofthiscourse,participantswillbeableto:•recognizethe

electricalwiringsystemregulations

•designbasicelectricalwiringsystemforelectricalequipmentsinbuilding

•selecteffectiveprotectiveequipmentsandsuitablecablesforelectricalmachineryandequipment

•systematicinspection,testingandreportingofcompletedbuildingwiringsystem

Who shoUld at tendEmployeesworkingwithelectricalequipment,Technicians,Chargeman,SafetyCommitteeMembersinIndustries

registration:• Upon Faxing / Mailing the completed Registration Form to FMM

Institute, Perak, you are deemed to have read and accepted the terms and conditions. The course would also be deemed as confirmed unless informed otherwise.

• Will be based on First-Come-First-Served basis.Payment:• Cheques made in favour of FMM InstItute should be forwarded

to FMM Institute Perak.• For SBL Scheme, an Attendance of 100% is a MUST, in any case,

employers will be billed in full.

Cancellation:MustbeinWritingwithReasons.• 7 days before the course ~ No Payment Charged• 3-6 days before the course ~ 50% Payment Charged• < 3 days before the course ~ Full Payment Charged• Participants who did not turn-up will be charged full payment.• Replacements can be accepted at no additional cost.

disclaimer:The FMM Institute reserves the right to change the facilitator, date and to vary / cancel the course should unavoidable circumstances arise. All efforts will be taken to inform participants of the changes.

submitted by:(Pleaseattachaseparatelistifspaceisinsufficient.)

Enclosed cheque / bank draft No. ______________________ for RM _______________ being payment for _______ participant(s) made in favour of the ‘FMM InstItute’ .

Name: Designation:

Company: Tel: Fax: Email:

Address:

FMMMembershipNo: MyCoID:

Dear sir / Madam Pleaseregisterthefollowingparticipant(s)fortheaboveprogramme:

name designation i.C. no.

1.

2.

3.

4.

Also available as an

In-House Course

rEgiStrAtion ForM

PrACtiCAL gUiDE to ELECtriCAL Wiring, inSPECtion, troUBLESHooting AnD rEPAiring

Closing date: october 2, 2013Medium of Instruction:EnglishCPD: 14hoursCoUrSE FEE (Fees include Course Materials, Refreshment, Lunch and Certificate of Attendance)FMMMembers RM500.00perpaxOthers RM600.00perpax

SBL Scheme

MAIntenAnCe / teCHnICALcate

gory

ADMiniStrAtiVE DEtAiLS

fMM institUte PeraK (Centre for Professional Development)Attn:PuanEda/MsHarvindar/MsNicole)No.1,LorongRajaDiHilir,OffJalanRajaDiHilir,30350Ipoh,Perak.Fax.No.:(05)5488221&(05)5488331•Tel.No.:(05)5488660Email:[email protected](475427-W)