panjab university chandigarh - onlinesaif.puchd.ac.in · round glass slide of size: 15 mm...
TRANSCRIPT
PANJAB UNIVERSITYCHANDIGARH
SOPHISTICATED ANALYTICAL INSTRUMENTATION FACILITY (SAIF)
&CENTRAL INSTRUMENTATION LABORATORY (CIL)
SAIF/CIL/UCIM/U
SIC
LAB VISITS & SYMPOSIA/CONFERENCES/WORKSHOPS ORGANIZED
06-04-2017 SSBUICET, PU, CHD OPTICAL MICROSCOPE 15
07-04-2017 AKAL UNIVERSITY, TALWANDI SABO TEM, SEM 30
10-04-2017 MATA GUJRI COLLEGE, FATEHGARH SAHIB TEM, SEM 15
11-04-2017 PEC, CHD XRD, SEM 15
25-04-2017 SHUATH, ALLAHABAD NMR, MASS, FTIR 15
27-04-2017 DEPT OF ZOOLOGY, PU. CHD TEM, SEM 15
23-05-2017 NITTTR, CHD XRD, FESEM, TEM 20
25-05-2017 SHOOLINI UNIVERSITY, SOLAN TEM, SEM 60
16-08-2017 MICROBIOLOGY, PU CHD TEM, SEM,FESEM, NMR, LCMS, FTIR, GC-MS
15
01-11-2017
DAV COLLEGE, CHD
TEM,SEM
25
09-11-2017
GOVT. COLLEGE, SEC-42, CHD
SEM, TEM, NMR, MASS
25
14-11-2017
NITTTR, CHD
XRD, SEM, TEM
20
16-11-2017
GCG-11, CHD
SEM
45
01-12-2017
GOVT. COLLEGE, MOHALI
NMR, UV, IR
15
22-12-2017
DIBRUGARH UNIVERSITY, ASSAM
SAIF/CIL, FACILITY
3
19-01-2018
CSIO, Chandigarh
NMR, XRD, SAXS
25
20-01-2018
FMC MEETING-2018
MEETING
-
14-03-2018
UIPS, PU
SAXS, XRD AND SEM
20
19-03-2018
Bio-Tech, PU
SEM AND TEM
15
21-03-2018
MATA GUJRI COLLEGE, FATEHGHARH SAHIB
SEM AND TEM
20
26-03-2018
MAHARAJA AGARSEN UNIVERSITY, BADDI
XRD, SEM, TEM, FTIR, UV, CHN
30
12-04-2018
ZOOLOGY, PU
SEM AND TEM
20
17-04-2018
PEC, CHANDIGARH
XRF, SEM AND TEM
15
22-05-2018
NITTTR, CHANDIGARH
XRD, SEM, TEM
25
29-08-2018
KHALSA COLLEGE FOR WOMEN, LUDHIANA
NMR, FTIR, UV, MASS
55
05-09-2018
FACULTY MEMBERS FROM ACADEMIC STAFF COLLEGE, PANJAB UNIVERSITY, CHANDIGARH
XRD, SEM, TEM, NMR, MASS, FESEM
40
S.NO.
NAME OF SEMINAR / CONFERENCE / WORKSHOP
DATE/S
1
WORKSHOP ON CONFOCAL MICROSCOPE
MAY 10-12, 2017
2
GIAN-X-RAY ABSORPTION SPECTROSCOPY: MATERIALS INSIDE-ANALYSIS TOOL
OCT. 3-8, 2017
3
GIAN-NEUROPHARMACOLOGY OF ADDICTION
OCT. 9-13, 2017
4
GIAN-CHEMICAL BIOLOGY AND DRUG DISCOVERY
OCT. 24-30, 2017
5
NATIONAL WORKSHOP ON SMALL ANGLE X-RAY SCATTERING (NSAXS-2017)
NOV. 6 -8, 2017
6
GIAN-POPULATION HEALTH PROMOTION: AN INTERNATIONAL PERSPECTIVE
DEC.18-24, 2017
7
ONE –DAY SEMINAR ON ELECTROCHEMICAL WORKSTATION
MAR. 3, 2018
8
NATIONAL CONFERENCE ON FUTURISTIC ASPECTS IN CHEMICAL SCIENCE AND TECHNOLOGY
APRIL. 28-29, 2018
9
GIAN-NANOSTRUCTURED METAL OXIDES FOR SENSING AND ENVIRONMENTAL APPLICATIONS
AUG, 6-10, 2018
Date VISITING INSTITUTE DETAILS INSTRUMENT'S NAME NO.
We are all pleased that department of SAIF/CIL/UCIM is excelling well beyond expectations. Since the department with new instruments and techniques provides wider service to a numerous educational institutions and industries that lack significant instrumentation facilities. Indeed, without any distinction, both internal and external users can be allowed to avail this facility with permission as per guidelines. On our part at the University has also provided funds out of PURSE programme for several Sophisticated Instruments and do our utmost to further improve the facilities and services. With the support of all researchers, I am sure that this department will be enhanced further to provide a comprehensive assistant that enables researcher to serve poor livings in the country.
Vice Chancellor
On behalf of the University and on my own behalf, I have great pleasure in welcoming all researchers to the Sophisticated Analytical Instrumentation Facility (SAIF)/Central Instrumentation Laboratory (CIL)/ University Center for Instrumentation and Micro Electronics (UCIM) of the Panjab University.
The Department of Science & Technology is supporting this center by providing liberal funds and it is a central facility with state-of-art sophisticated analytical instruments to cater the needs of faculties and research scholars in and out of the Panjab University.
Prof. RAJ KUMAR
Dear all,
Our department has been providing four different assistances: instrumentation facility to characterize molecules and materials, workshop facility to fabricate and repair analytical instruments required for researchers, and post graduation courses, M. Tech (Instrumentation) and M.Sc (Instrumentation), to improve knowledge of young researcher on instruments basics and utilizations and visiting our Labs.
Department has been proud of its record of dedicated and fast services in promoting quality of research and excellence. Moreover, department has bestowed with high quality expertize, who have rich industrial experiences and a passion for turning ideas into reality. Thus, on behalf of the Department and on my own, I invite young� and experienced researchers to make use of central instrumentation facilities available with us to characterize your materials from a molecular level!THANK YOU!
Prof. Surinder Kumar Mehta
Accordingly, department was named as Sophisticated Analytical Instrumentation Facility (SAIF), Central Instrumentation Laboratory (CIL) and University Center For Instrumentation and Micro Electronics (UCIM), respectively. The Department of Science & Technology (DST) and Panjab University have been bearing these centers by providing generous financial support.
Director
Message from Director Desk
Message from Vice Chancellor Desk
ABOUT PANJAB UNIVERSITY
Panjab University is one of the oldest Universities in India. It has a long tradition of pursuing excellence in teaching and research in science and technology, humanities, social sciences, performing arts and sports. The Panjab University, with its 78 teaching and research departments besides 4 chairs for the research on the main campus at Chandigarh, has 188 affiliated/constituent colleges spread over Punjab and Chandigarh besides Regional Centres at Muktsar, Ludhiana, Hoshiarpur and Kauni. In addition, there is the Vishveshawaranand Vishva Bandhu Institute of Sanskrit and Indological Studies (VVBIS&IS) at Hoshiarpur.
SAIF, formerly known as RSIC at Panjab University Chandigarh was incepted in the earlier years of the 6th plan. The complete facilities of SAIF, CIL and UCIM are working in unison in the service of research and also for imparting practical training to the students through workshops. The Centre also undertakes the design, fabrication and repair of electronic instruments required by students and teachers from the University and the colleges around. It also runs training programmes in technical skills for the benefit of scientific community and associated laboratory staff from different Institutions. Our facilities are .Instrumentation Facility, Workshop Facility, Visiting SAIF Labs, P.G Courses.
About SAIF/CIL/UCIM
UNIVERSITY & DEPARTMENT PROFILE
POST GRADUATE PROGRAMS AT
The University Center of Instrumentation & Micro Electronics was established in 1995-96 with a mandate to develop specially trained manpower in highly sophisticated field of Instrumentation. The center offers Post-Graduate Program in, M.Tech (Instrumentation) & M.Sc (Instrumentation). GATE qualified students are admitted in M.Tech (Instrumentation) course.
UNIVERSITY CENTER OF INSTRUMENTATION & MICROELECTRONICS - (UCIM)
These program provides necessary theoretical background and exposure in the latest technological developments in Instrumentation, thus providing a firm platform for the students to explore the research activities in the field of instrumentation.
Taking advantage of the complementary skills and expertise of the faculty, post graduate students pursue interdisciplinary and collaborative research activities with state-of-the-art resources available at UCIM. To enhance their innovative and creative capabilities students are required to undergo instrumentation related projects.
M.Sc 20 2 Years B.Sc. (Medical/Non-medical)/Physics/ On merit basis
Course Seats Duration Eligibility* Admission Criteria
(Instrumentation) ST+2 NRI Electrical / Electronics / Mechanical GATE Score:50%
Bio-medical Engineering or weightage : 50%
Computer Science/Vocational Physics/
Instrumentation/ Electrical and
Communication Engineering) with Electronics/Electronics & Electrical
minimum 50% marks in aggregate.
M.Tech 10+3 SC/ 2 Years B.E./B.Tech. (Chemical / Computer/ GATE qualified only
Physics / Electronics / Instrumentation
50% marks in aggregate. as approved by AICTE) with minimum
Production / Instrumentation / Academic
Electronics OR B.E. (E&TC/
equivalent degree /M.Sc. in
(Instrumentation) Electronics /Instrumentation Science /
COURSES OFFERED
SCANNING ELECTRON MICROSCOPE
Make: JEOL, Japan Model: JSM 6100, Year of Installation: 1985.
SPECIFICATIONS :
Accelerating Voltage :0.3 to 30 kV, Probe current : 10-12 to 10-6 A, Magnification : X10 to X 300,000, Resolution : 4.0 nm at 8 mm working distance
SAMPLE REQUIREMENT:
Sample should be in dry form; Biological Sample must be 100% Suspension after fixation and Dehydration. The Powder particle size must be in Micron level (i.e above 500 nm.)
400MHz FT-NMR SPECTROMETER
SPECIFICATIONS:
TOPSPIN NMR Data System1H, 13C & 2D experiments can be performedAuto shimming & auto tuning
Make: Bruker, Switerzland Model: Avance - II 400 MHZ Year of Installation: 2005
SAMPLE REQUIREMENT:
Samples are accepted in solid or liquid form. Compounds should be highly pure and soluble in commonly available solvents
. For 1H NMR sample quantity should be (CHLOROFORM/DMSO/D O)2
20-30 mg, however for 13 C and other nuclei it should be 50-60 mg.
TRANSMISSION ELECTRON MICROSCOPE
SPECIFICATIONS:
Working Voltage :40 to 120 kV, Magnification :6 lakh(Max), Resolution :0.36 nm (point to point), Detector: Charge couple device (CCD)
Make: Hitachi, JapanModel: H-7500Year of Installation: 2006
SAMPLE REQUIREMENT:
Powder Sample: ~ 5 mgLiquid Sample: ~ 1 mlStain (if required): PTA (1% to 2%) as per requirement
INSTRUMENTS UNDER SAIF
WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE
Make : Bruker, GermanyModel: S8 TigerYear of Installation: 2011
SPECIFICATIONS :
Suitable for solid, liquid and powder samples, Concentration range: PPM level to 100%, Analyze elements from carbon to uranium, It has 4k watt Rh anode X-Ray tube with proportional flow counter and scintillation counter detectors
SAMPLE REQUIREMENT:
Fine powder: 8 gm (less quantities e.g. 1 gm or 2-3 gm can be analyzed. Kindly contact lab. in-charge before submitting the sample) Geological samples: 9 gm (less than 9 gm will not be accepted) Liquid samples: 10 ml clear solution (no suspended particles)
X-RAY DIFFRACTOMETER
Make: PANalytical, Netherlands Model: X'Pert ProYear of Installation: 2007
SPECIFICATIONS :
Vertical goniometer having o orange of 5 to 140 2q.
Fixed divergence, anti scatter and receiving slits, Nickel beta filter, solid state X'celerator detector, 15 position sample changer, Copper anode,radiation Ka', Wavelength 1.54Å.
SAMPLE REQUIREMENT:
Fine powder: 1 gm Round glass slide of size: 15 mm (diameter) and 2 mm (thickness) Sample on glass slide of size: 35 mm x 25 mm and 2 mm (thickness)
LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
SPECIFICATIONS:
Mass range 50 to 2000 Daltons, ESI and lock spray ionization source (HRMS), Ms/Ms, Quadrupole analyzer with time of Flight Suitable for organic, inorganic, peptides, small proteins.
Make: Waters Corporation,U.K Model: Alliance 2795,Q-TOF Micromass Mass spectrometerYear of Installation: 2007
SAMPLE REQUIREMENT:
The amount of sample required for the analysis is 5-10 mg in solid or liquid form
FIELD EMISSION SCANNING ELECTRON MICROSCOPE
SPECIFICATIONS:
Ultra high resolution microscopy, Ultra-high resolution imaging, even at ultra low accelerating voltage (Resolution 1-1.3 nm at landing voltage 1.0 kV) Resolution 1nm at accelerating voltage 15kv
Make: Hitachi, JapanModel: SU 8010 Series Year of Installation: 2015
SAMPLE REQUIREMENT:
Powder Sample: ~ 5mg; Liquid Sample: 1ml; Solid: Length & breadth: less than 1 inch, width less than 5mm
LIQUID NITROGEN PLANT
SPECIFICATIONS :
StirLIN-1, Sterling Cryogenics Holland plant is installed at Panjab University SAIF. It has modern modular design, based on sterling closed cycle having helium as its working gas. The instrument is energy efficient, automatic and has controlled unattended operation. The dispensing pressure of Liquid nitrogen from storage vessel can be set from 0.2 bar(g) to 5 bar (g) as per requirement with, maximum purity of LN2 can be achieved up to 99.7% (0.3% oxygen contents). The production rate of usable cryofluid is 240 liters/day.
THE MOST COMMON APPLICATIONS ARE :
Superconductivity, High precision mechanical assembly, Cryosurgery Radiation detectors, Artificial insemination, Ultra high vacuum, Food industry for preservation, Nuclear field, Semiconductor industry etc.
MICROPHOTOGRAPHY
THE MOST COMMON APPLICATIONS ARE:
Photography of all kind of gels, plates & other macro-materials.
The Centre has a photographic laboratory equipped with serveral accessories as wide angle and telephoto lenses and special filters (polarizing and ultraviolet). This unit provides the following facilities to the scientists; B/W prints Photomicrography of slides (color/B/W) on latest Leica digital Micro-scope (with phase contrast polarisation attachment)
Make: NikonModel: SMZ1000Year of Installation: 2008
AVANCE NEO 500MHz FT-NMR SPECTROMETER
SPECIFICATIONS:
TOPSPIN NMR Data System1H, 13C, and 2D can be performedA sensitive 5 mm multinuclear smart probe allow to study a large number NMR sensitive nuclei including 19F NMR
Make: Bruker, Switerzland Model: Avance - II 500 MHZ Year of Installation: 2019
SAMPLE REQUIREMENT:
Samples are accepted in solid or liquid for. Compounds should be highly pure and soluble in commonly available solvents (CHLOROFORM/DMSO/D2O). For 1H NMR sample quantity should be 15-20 mg, however for 13C and other nuclei it should be ~ 50 mg.
CRITICAL POINT DRYER
Make: LeicaModel: EM CPD 300Year of Installation: 2018
SPECIFICATIONS :
Integrated touch screen with user interface for chamber based system for drying water based sample to super-critical state.
SAMPLE REQUIREMENT:
Any water based sample e.g. plant, tissue etc. Sample with appropriate size as per study.
ULTRACUT ELECTRON MICROSCOPE
Make: LeicaModel: Ultra Cut EM UC7Year of Installation: 2018
SPECIFICATIONS:
UC7 instrument configured with in built anti-vibration system with cutting window from 0.2-15 mm. Stepper motor for 10 mm (N-S movement) and 25 mm knife (E-W movement).
SAMPLE REQUIREMENT:
Bring appropriate size (~ 1-2 mm) of sample after fixation, dehydration for further processing of sample.
ICP MS ICAP
SPECIFICATIONS: Dynamic Range: > 9 orders of magnitude (< 1 - > 1·109 cps)Resolution: User definableHertz: 2mHz
Make: Thermo Scientific
Model: CAP RQ ICP-MS
Year of Installation: 2019
GAS CHROMATOGRAPHY MASS SPECTROMETRY
SPECIFICATIONS :
Ion Source Type: EI source programmable to 350 oC.Mass Range: 2.1100 amuModes: Full scan, SIM, timed-SIM, combined full scan/SIM, combined full scan/timed-SIM, SRM, timed-SRM, combined SRM/full scan Detectors: Flame Ionization Detector (FID), MS and Electron Capture Detector (ECD)
CHNS-O ELEMENTAL ANALYZER
HR TEM
SAMPLE REQUIREMENT:
Solid Form: 5-10 mg; Liquid form: 2-4ml; Note: Sample should be devoid of water
Make: THERMO Scientific, U.S. Model: Trace 1300GC coupled with THERMO TSQ8000 Triple Quadrupole MS Year of Installation: 2013
SPECIFICATIONS:
Suitable for solid, semi-solid samples, Determination of only CHNSO in percentage form, Samples such as organic, Inorganic, Polymers, peptides etc., can be characterized
Make: Thermo Scientific, U.S Model: Flash 2000 Year of Purchase: 2013
SAMPLE REQUIREMENT:
2 - 10 mg of dry and finely powdered sample is required for analysis.
SMALL ANGLE X-RAY SCATTERING
Make: Anton Paar Model: SAXSpace Year of Installation: 2017
SPECIFICATIONS :
X-ray Source: LFF sealed copper tube with line and point collimation X-ray optics: Multilayer mirrors, advanced kratky-based collimation systemDetector: EIGER R1 M (Hybrid photon counting detector)Sample Stage: TCStage 150, GI-SAXS stage, VarioStage
-1 -1Accesible q-range: q : 0.03 nm to q : 49 nmmin max
SAMPLE REQUIREMENT:
Liquid Sample : Monodisperse macromolecule sample with buffer (approx. 2ml). Sample should be clear/clean and free of aggregates. Concentration should be 5 mg/ml.Solid Sample : Sample should be fine powder (approx. 20 mg)
INSTRUMENTS UNDER CIL / PURSE
SPECIFICATIONS :
(UHR) Ultra High Resolution 0.194(HR) High Resolution 0.23(HT) High Specimen Tilt 0.25(CR) Cryo 0.27(HC) High Contrast 0.31Accelerating Voltage: 80, 100, 120, 160, 200 KVMinmum Step: 50 V
Make: JEOLModel: JEM 2100 PlusYear of Installation: 2019
FT-IR SPECTROPHOTOMETER
Make :Perkin Elmer, USAModel: Spectrum 400 FT-IR/FIR Spectrometer, Year of Installation: 2011
SPECIFICATIONS :
Multiple internal reflections, Diffused reflection, UATR, Resolution :0.4 cm-1 , Scan in range MIR 4000 cm-1 to 400 cm-1 FIR 700cm-1 to 30 cm-1
SAMPLE REQUIREMENT:
10 mg sample is required in the form of fine powder.
UV-Vis-NIR
SPECIFICATIONS:
Double Beam type, Operates between 0 to 100 C, Suitable for both glass thin film and liquid samples, Combined together FTIR one can analyze the samples in the wide range from 190nm – 3300nm.
Make: Perkin Elmer, USAModel: LAMBDA 750Year of Installation: 2011
SAMPLE REQUIREMENT:
5-10ml sample is required. For specular reflectance the samples with reflective surface are required.
Make: SAIYear of Installation: 2018SPECIFICATIONS: RF 300 W
Make: Nikon
Year of Installation: 2019Model: A1R Laser for multiphoton microscopy
Standard fluorescence detector (option)
Spectral detector (option)
Laser for confocal microscopy (option)NDD for multiphoton microscopy
Specification
Scan headDiascopic detector (option)
RF DC SPUTTER COATER CONFOCAL MICROSCOPE
SPECIFICATIONS:
Different tests can be performed like viscosity tests, flow curves, yield point measurements, thixotropy tests or temperature tests.
SAMPLE REQUIREMENT:
2 ml semi fluids like Gel, cream, emulsions, paints, coatings, food, pharmaceuticals, cosmetics, petrochemicals and asphalts
Make: Anton PaarModel: Rheolab QC Rotational RheometerYear of Installation: 2017
RHEOMETER
FACULTY & STAFF
Tejbir Singh WD-XRF 7837117161 0172-2534054 [email protected]
Avtar Singh NMR 9872202822 0172-2534059 [email protected]
Anoop Patyal LC-MS 9888397680 0172-2534058 [email protected]
Raj Kumar GC-MS 7566030197 / 9877401164 [email protected]
Neeraj jaswal CHN 7696380560 0172-2534062 [email protected]
Karan Verma FE-SEM 0172-2534080 [email protected]
M.B. Anitha SEM 9041613636 [email protected]
Sarbjeet Singh NITROGEN PLANT 8360804187
Navjot Singh AC plant/Electronic Workshop 9814770155
TEMPORARY TECHNICAL STAFF
Honorary Director
S. K. Mehta
2534046, 9417786061
Associate Professor
H. P. S. Kang
2534055
Assistant Professor
Anil Kumar Sharma
2534050, 9876191493
Poonam Kumari
2534051, 9872663277
Ramesh K Sharma
2534058, 9815604963
Scientific Officer
Balbir Singh
2534050, 9872996186
Rajender Singh
2534057, 9501239960, 9817015213
Technical Officer (Re-employed)
Avtar Singh
2534059, 9872202822
Assistant Technical Officer
Arun Kumar Sharma 2534048, 9872547156
Senior Assistant
Mamta
2541065, 2534047, 7986754492, 8437469204
Manish Kumar
2534047, 9781012525
Narinder Kumar
2534047, 9876133486
Senior Technician -
G II
Jagtar Singh
2541065, 2534081, 9888368019
Kewal Kumar 2534083, 9872212164
Mohinder Singh
2534057, 9815616114
Junior Technician - G III
Dharamvir 2534082, 9779303149
Geeta Arora
2534050, 9872981211
Om Parkash 2534050, 9468472256
Subhash Chand 2534062, 8872081092 [email protected]
Uttam Chand 2534056, 2534047, 9814993598
Priyanka 2541065, 9988268967, 9888282027 [email protected]
Steno-Typist
400MHZ FT-NMR SPECTROMETER
Facilities P.U Other Educational Inst. R&D Industry 1 D (1H NMR,13C NMR, CDCL3/ D2O 320 400+18% GST 1200+18% GST 2000+18% GSTDEPT Experiment, DMSO-d6 520 600+18% GST 1400+18% GST 2200+18% GSTNMR of any other Nucleus) (for each sample)
2D (2DCOSY, NOESY, CDCL3 / D2O 640 800+18% GST 2400+18% GST 4000+18% GST
Any other 2D experiment)
Experiments, HSQC, ROESY, DMSO-d6 840 1000+18% GST 2600+18% GST 4200+18% GST
(for each sample)
TOCSY, HMBC Experiment,
LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
Facilities P.U Other Educational Inst. R&D Industry MASS 480 600+18% GST 1800+18% GST 3000+18% GSTLCMS 800 1000+18% GST 3000+18% GST 5000+18% GSTMS-MS 640 800+18% GST 2400+18% GST 4000+18% GSTHRMS 800 1000+18% GST 3000+18% GST 5000+18% GST
GAS CHROMATOGRAPHY MASS SPECTROMETRY
Powder/ Solid Samples 480/- 600/-+18% GST 1800/- +18% GST 3000/- +18% GST
FESEM 960 1200+18% GST 3600+18% GST 6000+18% GST
CHNS 640 800+18% GST 2400+18% GST 4000+18% GST
Mapping 240 300+18% GST 900+18% GST 1500+18% GST
GCMS 800 1000+18% GST 3000+18% GST 5000+18% GST
CHNS-O ELEMENTAL ANALYZER
Facilities P.U Other Educational Inst. R&D Industry
Facilities P.U Other Educational Inst. R&D Industry
Facilities P.U Other Educational Inst. R&D Industry
FIELD EMISSION SCANNING ELECTRON MICROSCOPE
WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE
CHNS-O 1280 1600+18% GST 4800+18% GST 8000+18% GST
(Charges as per Element)
Facilities P.U Other Educational Inst. R&D Industry
EDX 240 300+18% GST 900+18% GST 1500+18% GST
MS only / GC only 480 600+18% GST 1800+18% GST 3000+18% GST
Liquid Samples 320 400+18% GST 1200+18% GST 2000+18% GST
30 40+18% GST 50+18% GST 100+18% GST
SMALL ANGLE X-RAY SCATTERING
P.U Other Educational Inst. R&D Industry
500 1000+18% GST 3000+18% GST 5000+18% GST
160 200+18% GST 600+18% GST 1000+18% GST
LIQUID NITROGEN
FT-IR SPECTROPHOTOMETER
P.U Other Educational Inst. R&D Industry
P.U Other Educational Inst. R&D Industry
MICROPHOTOGRAPHY
UV-VIS-NIR
70 90+18% GST 270+18% GST 450+18% GST
15/shot 20/shot+18% GST 40/shot+18% GST 100/shot+18% GST
P.U Other Edu. Inst. R&D Industry
P.U Other Edu. Inst. R&D Industry
P.U Other Edu. Inst. R&D Industry 50 60+18% GST 180+18% GST 300+18% GST
TRANSMISSION ELECTRON MICROSCOPE
REOMETER
P.U Other Edu. Inst. R&D Industry 800 1000+18% GST 3000+18% GST 5000+18% GST
320 400+18% GST 1200+18% GST 2000+18% GST
SCANNING ELECTRON MICROSCOPE
P.U Other Edu. Inst. R&D Industry
P.U Other Edu. Inst. R&D Industry
560 700+18% GST 2100+18% GST 3500+18% GST
X-RAY DIFFRACTROMETER
Ÿ WORKSHOP CHARGES - as per job requirementŸ SEMINAR HALL BOOKING - Rs. 3500/- (for Panjab University) & Rs. 3500/- + Tax @ 18% (External)Ÿ LAB VISIT CHARGES – 750 + TAX @18%,
LAB VISIT, SEMINAR HALL & WORKSHOP CHARGES
CHARGES OF ANALYSIS
SAIF / CIL / UCIM / USICPANJAB UNIVERSITY, SECTOR 14, CHANDIGARH, U.T. - 160014, INDIA
TEL.: +91 172 2534046 | E-mail: [email protected] | www.onlinesaif.puchd.ac.in
GateNo. 3
GateNo. 2
GateNo. 1
SAIF/CIL
PANJAB UNIVERSITYCHANDIGARH
SECTOR 15SECTOR 25
SECTOR 12PGI
SECTOR 11
SEMINAR HALLRECEPTION
w.e.f. December 17, 2018 sample submission for SAIF Instruments will be accepted only through Online request form available at webpage https://onlinesaif.puchd.ac.in
Electrical WorkshopWood Workshop Mechanical Workshop Glass Blowing Workshop