panduit jack novo 104995
TRANSCRIPT
TX6A 10Gig Shielded Jack Module
Page 1 of 2
INSTALLATION INSTRUCTIONS©Panduit Corp. 2010
For Technical Support: www.panduit.com/resources/install_maintain.asp
Part Numbers: CJS6X88TGY, CJSK6X88TG**, CJSQ6X88TG**
Braid
Conductors
Individual FoilPair Screen
S-STP / PIMF
CableEnd 1
CableEnd 2
32 4
Cable End 1 Cable End 2
Pr1
Pr2
Pr3
Pr4
Pr4
Pr1
Pr2
Pr3
TERMINATION STEPS
5
1
Jack
Wire Cap
StrainReliefCollar
U/FTP
Drain Wire
Conductors
Individual FoilPair Screen
6 EGJT
** Denotes color.
PN366K
Page 2 of 2
INSTALLATION INSTRUCTIONS
For Instructions in Local Languagesand Technical Support:
http://www.panduit.com/resources/install_maintain.asp
E-mail:[email protected]
Fax:(708) 444-6993www.panduit.com
Cable End 1
Cable End 2
Cable End 1
Cable End 2
7
T568B T568A
12
1
3
1
2
3
1
2
3
See note 4.
2
CWST
8
9
EGJT
10
11
CJSGK-XKIT
1 2
REMOVAL STEPS
3
Notes:1. For specified performance, follow TIA/EIA 568-C installation guidelines.2. Jack Modules can terminate 22-26 AWG solid or stranded IWC data cable with 0.062 inch (1.57 mm) maximum insulated conductor outside diameter.3. Jack Modules may be re-terminated a minimum of 20 times.4. On cable end 2 for A & B wiring and cable end 1 of A wiring, wrap the designated pairs around the proper center dividing post (A or B) and terminate in the proper location.5. CJSGK-X Grounding Kit is REQUIRED for all Mini-Com Modular Patch Panels, but is optional for Mini-Com All Metal Shielded Modular Patch Panels.6. For technical and performance information, consult Panduit Technical Support.As with all Wiring Accessories, the following statements apply:1. Never install communications wiring during a lightning storm.2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.4. Use caution when installing or modifying communication wiring.
See note 5
12
Drain WireU/FTP
©Panduit Corp. 2010 PN366K