Page 1: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR®

Oral maxillofacial surgery

Page 2: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR®

biomaterial

years of provenclinical history

30+MEDPOR has been a trusted name in the industry since 1985, with hundreds of thousands of procedures performed, and hundreds of published clinical reports in reconstructive, cranial, oculoplastic, and cosmetic applications.

Our MEDPOR product line provides you an array of porous polyethylene solutions for your reconstruction and augmentation needs. We understand that bio-compatibility characteristics of implants are paramount to help surgeons achieve positive patient outcomes. The omni-directional pore structure of our polyethylene implants may increase implant acceptance by allowing the patient‘s native tissue to integrate with the implant. In addition to our comprehensive line of stock MEDPOR implants, we offer CT-based patient specific implants, putting the implant design in your hands.

Page 3: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

• MEDPOR is easy to work with. The material can be trimmed with a blade in the sterile field, carved and feathered intra-operatively for an excellent final fit.

• No pre-placing of fixation plates. MEDPOR can be easily drilled and fixated and is designed to accept screws and plates without cracking, giving the surgeon more flexibility in fixation options and placement.

• MEDPOR surgical implants can be cut with a variety of surgical instruments. Implants may require fitting to the defect area at the time of surgery. The implant edges can be delicately shaped and feathered for a smooth transition from the implant to the patient’s own bony contour.

• MEDPOR surgical implants are provided sterile and should not be resterilized.

• Do not place or carve the implant on surgical drapes, surgical clothing or any other surface that may contaminate the implant with lint and other particulate matter.

Page 4: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

Implants designed using CT-scan data to approximate the anatomy of the orbital floor & medial wall to enhance the effectiveness and efficiency of reconstruction.MEDPOR coating minimizes sharp edges even if the plates require modification, and the superior, non-porous barrier side helps prevent tissue ingrowth along the aspect of the globe.

3D Orbital floor

a b

c

d

Catalog # Description

81041 MEDPOR TITAN 3D Orbital floor, MTB left small

81042 MEDPOR TITAN 3D Orbital floor, MTB right small

81043 MEDPOR TITAN 3D Orbital floor, MTB left large

81044 MEDPOR TITAN 3D Orbital floor, MTB right large

01-01820 Plate holding forcep

Plate A B C D

Large L/R36mm(1.4 in.)

37mm(1.4 in.)

17mm(0.6 in.)

1.2mm

Small L/R32mm(1.2 in.)

35mm(1.4 in.)

13mm(0.5 in.)

1.2mm

MEDPOR TITAN®

Configurations

MTMTitanium mesh embedded wit-hin porous, high-density pol-yethylene.

MTBTitanium mesh embedded within a porous polyethylene matrix with a solid, barrier surface on one side, potentially allowing for fibrovascular ingrowth only on the porous side of the implant.

BTBTitanium mesh embedded within solid, non-porous high-density polyethylene. The smooth barrier surface can prevent fibrovascular ingrowth.

Combines high-density polyethylene and titanium mesh in a single implant for increased flexibility, shape retention, radiographic visualization and strength1.

Page 5: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR Oral maxillofacial surgery

US Patent 7,655,047

TITAN Orbital Floor and Wall (OFW)

TITAN implants

CAT# Description A (mm) B (mm) C (mm) Thickness

81034 MAX MTM 42 41 1.0 0.85

81035 MAX MTB - Left 42 41 1.0 1.0

81036 MAX MTB - Right 42 41 1.0 1.0

CAT# Description A (mm) B (mm) C (mm) Thickness

81030 MTM 42 41 0.5 0.85

81031 MTB - Left 42 41 0.5 1.0

81032 MTB - Right 42 41 0.5 1.0

81033 BTB 42 41 0.5 0.6

CAT# Description A (mm) B (mm) Thickness

81020 MTM 50 76 0.85

81021 MTM 38 50 0.85

81022 MTM 38 50 1.50

81023 MTM 50 76 1.50

81024 BTB 38 50 0.60

81025 BTB 50 76 0.60

81026 MTB 38 50 1.00

81027 MTB 50 76 1.00

81028 MTB 38 50 1.60

81029 MTB 50 76 1.60

Page 6: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

A

B

MEDPOR Oral maxillofacial surgery

MEDPOR TITAN Orbital Floor and WallSheets

CAT# Description A (mm) B (mm) Thickness

83020 Micro thin sheet 38 50 0.25

83022 Micro thin sheet 38 50 0.35

8438 Micro thin sheet 30 50 0.40

83029 Micro thin sheet 38 50 0.45

83030 Micro thin sheet 50 76 0.45

MEDPOR biomaterial sheets provide the surgeon with options for craniofacial reconstruction and augmentation.

6330 Sheet 38 50 1.50

6331 Sheet 50 76 1.50

8662 Sheet 76 127 1.50

9562 Sheet 38 50 3.00

7210 Ultra thin sheet 38 50 0.85

7212 Ultra thin sheet 50 76 0.85

7214 Ultra thin sheet 76 127 0.85

A

0.25mm

0.35mm

0.40mm

0.45mm

0.85mm

1.50mm

3.00mm

Thickness

B

Available in two configurations, with or without a BARRIER

TITAN fan

CAT# Description A (mm) B (mm) Thickness

81049 MTM 40 61 0.85

81050 MTB 40 61 1.00

BARRIER sheets

CAT# Description A (mm) B (mm) Thickness

8305 Orbital floor implant 38 50 1.00

9305 Orbital floor implant 38 50 1.60

8312 Rectangle 50 76 1.00

9312 Rectangle 50 76 1.60

Page 7: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR Oral maxillofacial surgery

The contoured two-piece chin implant is designed with a gradual taper and concave posterior surface to provide an excellent anatomical fit to the bony anatomy.

Contoured two-piece chin implants

CAT# Description A (mm) B (mm) C (mm)

86000 Contoured two-piece chin 72 42 3

86001 Contoured two-piece chin 74 42 5

86002 Contoured two-piece chin 78 50 7

86003 Contoured two-piece chin 80 55 9

85001 Chin sizer set for contoured two-piece (silicone, non-sterile)

The RZ extended chin implants are available in designs with square or round anterior projections. The extended chins contain a notch for mental nerve passage and provide tri-dimensional projection (anterior, lateral and inferior).

The two-piece design is joined at the midline by a separate tab that allows individual placement of the left and right portions.

RZ extended chin implants

CAT# Description A (mm) B (mm) C (mm)

8313 RZ extended round chin - small 45 47 3

8314 RZ extended round chin- medium 45 47 5

8315 RZ extended round chin - large 45 47 7

8316 RZ extended square chin - small 45 47 3

8317 RZ extended square chin - medium 45 47 5

8318 RZ extended square chin - large 45 47 7

9954 Chin sizer set for extended designs (silicone, non-sterile)

Page 8: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR Oral maxillofacial surgery

The two-sectional components of this anatomical MEDPOR chin design allow for easy insertion and placement of the implant. The surgeon can then link the components together for proper alignment.Sizer set available.

Two-piece chin implants

The MEDPOR button chin implant, designed in a three dimensional configuration, is an option for augmentation to the medial anterior point of the chin.

Button chin

CAT# Description A (mm) B (mm) C (mm)

86010 Button chin - small 40 25 4

86011 Button chin - medium 47.5 37.5 5.5

86012 Button chin - large 48.5 38 7

CAT# Description A (mm) B (mm) C (mm)

8320 Small projection 56 33 5

8321 Medium projection 56 36 7

8322 Large projection 57 38 9

9953 Chin sizer set for two-piece design (silicone, non-sterile)

Page 9: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR Oral maxillofacial surgery

The ES angle of the mandible series is designed to provide a modest inferior ridge and lateral profile for augmentation and correction of deficient mandibular angles.

The E series is a reconstructive set of angles with larger dimensions available for significant augmentation. The lateral projection as well as the inferior ridge has greater bulk than the ES series.

Angle of the mandible implants

CAT# Description A (mm) B (mm) C (mm) D (mm) IP (mm) LP (mm)

7537 Ramus with inferior ridge E-5 - left 79 32 5 10 5 7

7538 Ramus with inferior ridge E-5 - right 79 32 5 10 5 7

7539 Ramus with inferior ridge E-10 - left 79 32 10 10 10 7

7540 Ramus with inferior ridge E-10 - right 79 32 10 10 10 7

7541 Ramus with inferior ridge ES-5 - left 79 32 5 4 5 5

7542 Ramus with inferior ridge ES-5 - right 79 32 5 4 5 5

7543 Ramus with inferior ridge ES-10 - left 79 32 10 4 10 5

7544 Ramus with inferior ridge ES-10 - right 79 32 10 4 10 5

The lateral augmentation onlay mandible angle is designed to provide augmentation to the lateral profile at the posterior body of the angle. The lateral augmentation onlay mandible provides 6.5mm’s of thickness at the angle of the mandible. A small inferior ridge along the ramus allows the implant to conform to the mandibular border.

Lateral augmentation onlay shape

CAT# Description A (mm) B (mm) C (mm) D (mm) IP (mm) LP (mm)

7535 Mandible angle - left 47 38 3 3 3 6.5

7536 Mandible angle - right 47 38 3 3 3 6.5

Page 10: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

The RZ mandibular angle implants are wraparound designs that conform to the posterior and inferior borders of the mandible angle.

Sizer set available.

RZ mandibular angle implants

MEDPOR Oral maxillofacial surgery

CAT# Description A (mm) B (mm) C (mm)

9955 Mandibular angle RZ left - small 65 35 3

9956 Mandibular angle RZ right - small 65 35 3

9957 Mandibular angle RZ left - medium 65 35 7

9958 Mandibular angle RZ right - medium 65 35 7

9959 Mandibular angle RZ left - large 65 35 11

9960 Mandibular angle RZ right - large 65 35 11

9566 RZ mandibular sizer set (Silicone, Non-sterile)

The MEDPOR contoured mandibular angle is anatomically shaped for augmentation of the mandibular ramus and body to the mental foramen. The anatomical shape of this implant is designed to minimize dead space under the implant as well as the need for reshaping at the time of surgery.

Contoured mandibular angle implants

CAT# Description A (mm) B (mm) C (mm) D (mm)

88037 Contoured mandibular angle - left 59 29 7 11

88038 Contoured mandibular angle - right 59 29 7 11

Page 11: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

MEDPOR Oral maxillofacial surgery

Individually designed implants

CAT# Description

54440510 MEDPOR patient specific midface

54440610 MEDPOR patient specific mandible augmentation

iD SolutionsTM

Individually designed. Personalized care.

Facial iD

- Reconstruction and augmentation

MEDPOR implants are built from patient CT data and offer you the ability to design an implant that fits your patients re-constructive or augmentation needs.

Each MEDPOR implant kit contains two (2) identical sterile implants and one (1) sterile host bone model (defect area). The host bone model is provided as a preoperative guide to demonstrate orientation and fit of the customized implant(s).

Page 12: Oral maxillofacial surgery - Stryker CMF · MEDPOR Oral maxillofacial surgery ... Please contact your Stryker representative if you have questions about the availability of Stryker

Stryker Craniomaxillofacial Kalamazoo, MI 49002 USA t: 269 389 5346 toll free: 800 962 6558 f: 877 648 7114

cmf.stryker.com

This document is intended solely for the use of healthcare professionals. A surgeon must always rely on his or her own professional clinical judgment when deciding whether to use a particular product when treating a particular patient. Stryker does not dispense medical advice and recommends that surgeons be trained in the use of any particular product before using it in surgery.

The information presented is intended to demonstrate a Stryker product. A surgeon must always refer to the package insert, product label and/or instructions for use, including the instructions for cleaning and sterilization (if applicable), before using any Stryker product. Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets.

Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: BARRIER, BTB, Facial iD, iD Solutions, MEDPOR, MEDPOR TITAN, MTB, MTM, RZ, Stryker, TITAN. All other trademarks are trade-marks of their respective owners or holders.

Devices may not have been licensed in accordance with Canadian Law.

1: Holck, D., Foster J., and Dahl T., “Custom Shaped Porous Polyethylene-Titanium Mesh Orbital Implants for Internal Orbital Floor/Medial-Wall Fracture Repair” ASOPRS 37th Annual Fall Scientific Syllabus, pp190, November 15-16, 2006

Literature Number: CMF_BR_93-Rev. None_13908 Copyright © 2017 StrykerPrinted in the USA

Craniomaxillofacial