operator site plan model hctdcu specialty … hctdcu specialty overhead door and gate operator out...
TRANSCRIPT
Mo
del
HC
TD
CU
SP
EC
IALT
Y O
VE
RH
EA
D D
OO
R A
ND
GAT
E O
PE
RAT
OR
OUTInterruptLoop
ExitLoopShad
owLoop
IN
OUTInterruptLoop
ExitLoop IN
Shadow
Loop
OUOUUUOUOU
OUOUOUOUOUOUOUOUOU
OUOUOUOUOUOUOUOUOUOUOUOUOUOUOUUOUOU
Batteries7AHStandard 7 AMP-Hour Battery, 12 Vdc, to replace original batteries provided with operator. Reuse existing harnesses.
Plug-In Loop DetectorIncludes 8 sensitivity settings and boost, ensures vehicles are easily identifi ed.
© 2016 LiftMaster All Rights Reserved
300 Windsor Drive, Oak Brook, IL 60523
LiftMaster.com
PAS023
Internet Protocol Door Controller Cost effective, fl exible cloud-based accessgate/door controller for perimeter and interior entrances.
Universal DIP Single-Button and 3-Button Remote ControlThese remote controls are ideal for applications such as gated communities or commercial applications requiring a large number of remotes for a common entrance.
2-Button and 4-Button Security+ 2.0® Learning Remote ControlsThese remote controls are ideal for gated communities. One button can control a gate operator and the other(s) can control a garage door. It can also be programmed to different codes and frequencies.
MODEL HCTDCUPIVOT GATE EXAMPLE
SECTIONAL DOOR EXAMPLE
ACCESSORY OVERVIEW
Operator Site Plan
Entrapment Protection DevicesThis operator contains an inherent (internal) entrapment protection system and REQUIRES the addition of a LiftMaster external monitored entrapment protection system (non-contact photoelectric sensor or contact edge sensor) for EACH entrapment zone prior to gate/door movement. Model CPSUN4G is provided with operator. See back page.
ACCESSORY MODEL
Entrapment Protection Devices . . . . . . . . . . . . . . . . . . . . . . . . . . See back page
Plug-In Loop Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOOPDETLM
Red/Green Traffi c Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RGL24LY
Universal DIP Single Button Remote Control . . . . . . . . . . . . . . . 811LM
Universal DIP Three Button Remote Control . . . . . . . . . . . . . . . 813LM
Security+ 2.0® 2-Button Remote Control . . . . . . . . . . . . . . . . . . 892LT
Security+ 2.0® 4-Button Remote Control . . . . . . . . . . . . . . . . . . 894LT
Wireless Commercial Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . KPW250
LiftMaster Internet Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . 828LM
7AH Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-NP712
Internet Protocol Door Controller . . . . . . . . . . . . . . . . . . . . . . . . IPACIPDCC
Access Control Receiver Security+ 2.0® . . . . . . . . . . . . . . . . . . . STAR1000
Telephone Entry/Access Control System . . . . . . . . . . . . . . . . . . EL2000SS
3-Button Passport MAX Visor Remote Control. . . . . . . . . . . . . . PPV3M
SOLAR
10 Watt 12V Solar Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP10W12V
20 Watt 12V Solar Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP20W12V
Solar Battery Harness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . K94-37236
ACCESSORY CHECKLIST
ORDER SUMMARY
Customer: Date:
Project:
Architect/Engineer:
Contractor:
Gate/Door Length (ft.): Gate/Door Weight (lbs.):
Solar (Y/N):
Power Source (120 or 240 VAC):
LiftMaster gate operators comply with UL 325 standards. IMPORTANT: To be compliant with UL 325 and industry safety guidelines, LiftMaster qualifi ed monitored external entrapment protection devices such as photoelectric sensors or edge sensors are required to be installed with this operator.
Red/Green Traffi c Light:Indicates the gate/door position. Provides assurance of safe entering and exiting of the facility, reducing the potential for costly accidents.
ENTRAPMENT PROTECTIONINSTALLATION OVERVIEW
CONTACT SENSORS (EDGE SENSORS)
POWER WIRING
MOUNT THE OPERATOR
OPERATOR DIMENSIONS
DETERMINE LOCATION FOR OPERATOR
OPERATOR SPECIFICATIONS
NOTE: Use copper conductors ONLY.
This operator contains an inherent (internal) entrapment protection system and REQUIRES the addition of a LiftMaster external monitored entrapment protection system (non-contact photoelectric sensor or contact edge sensor) for EACH entrapment zone prior to gate movement. An entrapment zone is every location or point of contact where a person can become entrapped between a moving gate and a stationary object. Your application may contain one or many entrapment zones. System includes six monitored entrapment protection inputs capable of covering all entrapment zones. Use only LiftMaster approved entrapment protection devices.
NON-CONTACT SENSORS
Model LMWEKITULiftMaster Monitored Wireless Edge Kit (Transmitter and Receiver)
Model L50, L504AL, L505AL, and L506ALLarge Profi le Monitored Edge (82 ft. roll)Aluminum Channel (4 ft., 5 ft., 6 ft.)
Model L50ELarge Profi le Ends Kit (10 pairs)
Model S50, S504AL, S505AL, and S506ALSmall Profi le Monitored Edge (82 ft. roll)Aluminum Channel (4 ft., 5 ft., 6 ft.)
Model S50ESmall Profi le Ends Kit (10 pairs)
Model L50CHPPVC Channel for Both Large and Small Profi les (8 ft., pack of 10)
Model LMTBULiftMaster Monitored Through Beam Photoelectric SensorModel LMRRULiftMaster Monitored Retro-Refl ective Photoelectric SensorModel CPSUN4GLiftMaster Monitored Through Beam Photoelectric SensorNOTE: CPSUN4G is provided with the operatorModel CPS-OPEN4LiftMaster Monitored Dual-Sided Photoelectric Sensor
Model L50CHALAluminum Channel for Both Large and Small Profi les (10 ft., pack of 8)
Models WS4, WS5, and WS6Wraparound Square Monitored Edge (4 ft., 5 ft., 6 ft.)
Models WR4, WR5, and WR6Wraparound Round Monitored Edge (4 ft., 5 ft., 6 ft.)
Model ETOOLCutting Tool for Edge Material
OES-SD16, OES-SD24Optical Edge System for Overhead Doors (16 ft., 24 ft.)
OES-4504PVC Channel (1-3/4" x 1-3/4")
OES-5104PVC Channel (2" x 2")
7.5" (19.1 cm)
4.1" (10.3 cm)
7.8"(19.9 cm)
17.5"(44.5 cm)
HCT08: 139" (353 cm)HCT10: 163" (414 cm)HCT12: 187" (475 cm)
HCTDCU
HCTDCU
23.8"(60.3 cm)
Usage Classifi cation Class II, III, and IV
Main AC Supply 120 Vac, 4 Amps OR 240 Vac, 2 AmpsSystem Operating Voltage 24 Vdc Transformer Run / Battery Backup
Accessory Power 24 Vdc, 500mA max. for ON + SW (switched)Solar Power Max 24 Vdc at 60 watts max.Variable Operating Lengths (Operator Weights)
8 foot (2.4 m) gate - 11.75 foot (3.6 m) operator length (130 lbs. [58.9 kg])10 foot (3.1 m) gate - 13.75 foot (4.2 m) operator length (145 lbs. [65.7 kg])12 foot (3.7 m) gate - 15.75 foot (4.8 m) operator length (160 lbs. [72.5 kg])
Maximum Gate/Door Weight 700 lbs. (317.5 kg) Maximum Gate/Door Width (sectional and one-piece)Maximum Gate/Door Height
22 ft. (6.7 m)
12 ft. (3.7 m)Travel Speed BIPART Delay OFF (Default) - 8 inches (20.3 cm) per second
BIPART Delay ON (Fast) - 11 inches (27.9 cm) per second (open speed only)Maximum Daily Cycle Rate ContinuousMaximum Duty Cycle ContinuousOperating Temperature -20°C to 60°C (-4°F to 140°F)Expansion Board Provided
Inherent Entrapment Protection (Type A)
Dual - RPM and Current Sense
External Entrapment Protection (Type B1 and/or Type B2)
3 inputs per board - any combination of up to 3 photoelectric sensors and up to 2 edge sensors
Power Wiring Sockets (120 Vac factory default)
EMI BOARD
Input Power Connection
HOT
NEUT
RAL
GROU
ND
Black
Green
White
Whi
te
Red
Piggy Back
AC PowerSwitch
Power Wiring Connector
Use UL listed conduit to enclose power wires
American Wire Gauge (AWG)
Maximum Wire Length (120 Vac)
Maximum Wire Length (240 Vac)
14 130 feet (39.6 m) 260 feet (79.3 m)
12 205 feet (62.5 m) 410 feet (125 m)
10 325 feet (99.1 m) 650 feet (198.1 m)
8 520 feet (158.5 m) 1040 feet (317 m)
6 825 feet (251.5 m) 1650 feet (502.9 m)
4 1312 feet (399.9 m) 2624 feet (799.8 m)
2. Open the gate/door and mark the center point on the ceiling.1. With the gate/door closed, mark the center.
1. Place the motor unit on packing material to protect the cover. Make sure the header bracket is in the center of the opening. Bolt or weld the header bracket to the wall.
2. Lift the operator and align with center mark on ceiling. Have someone hold the operator in place or use a post as a temporary support. Bolt the operator to the ceiling. (A support post is not part of the operator. Use only for installation.)
3. Bolt or weld arm to gate/door.
Header Bracket Header Bracket
Temporary Support Post
Concrete Anchor 1/2" x 3 1/2"
Brackets (not provided)
Flush Mount
Arm
Door Arm