new data center and transport interconnect technology

19
New Data Center and Transport Tom McDermott Fujitsu Network Communications, Inc. October 30, 2014 New Data Center and Transport Interconnect Technology All Rights Reserved, ©2014 Fujitsu Network Communications

Upload: trantram

Post on 21-Dec-2016

222 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: New Data Center and Transport Interconnect Technology

New Data Center and Transport

Tom McDermottFujitsu Network Communications, Inc.October 30, 2014

New Data Center and Transport Interconnect Technology

All Rights Reserved, ©2014 Fujitsu Network Communications

Page 2: New Data Center and Transport Interconnect Technology

Changing Requirements

� Datacenters are expanding in size.� Continued need for 100m / MMF intra-DC connection.� Growing need for 500m~2km / SMF intra-DC connections.� Interest in breakout / fanout capabilities

� Ethernet WAN / Transport Interconnect.� 2km, 10km, 40km – continued need. SMF

� 100GE.� 100GE.� 2nd generation of devices becoming available.� Smaller size, lower cost, lower power.

� 400GE project started.� Intra-DC, Inter-DC, and Metro reach objectives.

� New class of coherent tunable pluggable T/Rs.� Metro reach & compatible with ROADMs� Optical reach over ROADM still TBD.

1All Rights Reserved, ©2014 Fujitsu Network Communications

Page 3: New Data Center and Transport Interconnect Technology

Some Ethernet PMD Nomenclature

� 100GBASE-SR4

100GEShort Reach(100 m) over

MMF

4 optical lanes

� 100GBASE-LR4 = 10 km over duplex SMF

� ER4 = 30 km (40 km with engineering).

� 100GBASE-CR4 = 4 Copper twin-ax cables (each direction) ~ 5m

� 100GBASE-KR4 & KP4 = 4 Copper backplane diff traces (each direction) ~ 1m

2All Rights Reserved, ©2014 Fujitsu Network Communications

Page 4: New Data Center and Transport Interconnect Technology

Breakout / Fanout

� Growing interest in breakout / fanout functionality� Increase density in top of rack (TOR) switches

• Example: a 40GE 40GBASE-SR4 module could be operated in two modes:• 4 x 10GE – QSFP+ physically smaller than 4 separate 1 x 10GE plugs

• 1 x 40GE – data is striped across the 4 lanes.

• Provides high-density 10GE fanout from TOR switch• Provides high-density 10GE fanout from TOR switch

• Fiber-ribbon to duplex fiber conversion is external.

� Recent discussion: 100GE 4-lane module (4 x 25G VCSEL):• 4 x 25GE - An IEEE 802.3 25GE Study Group is underway.

• 1 x 100GE - 802.3bm currently balloting 100GBASE-SR4

3All Rights Reserved, ©2014 Fujitsu Network Communications

Passive

MMFribbon

Page 5: New Data Center and Transport Interconnect Technology

Density Evolution 10GE � 100GE2002 � 2014

Front-PanelBandwidth

Density(GB per 10

mm)

58.4

73

CFP4

QSFP28

CXP (MMF)37.7

(2014)

(2008-2010)

10G 40G 100G

XFPSFP+

XFP4 xSFP+

4

5.457.30

29.2

Port Bandwidth

4 x

QSFP (MMF) QSFP+ (MMF)

CFP13.7

CFP227.4

CXP (MMF)37.7

CPAK

All Rights Reserved, ©2014 Fujitsu Network Communications

(2002)

(2006) (2013)

(2010)

(2012)

(2012)

(x 4)

(x 4)

Page 6: New Data Center and Transport Interconnect Technology

100GE Package Evolution

CFP

CFP

CFP

CFP

CFP

2C

FP

2C

FP

2C

FP

2

100G

Today: CFP:

10x10MSA,

100GBASE-LR4

100GBASE-ER4

100GBASE-SR10

Future: Digital DWDM

Today: CFP2:

100GBASE-LR4,

100GBASE-ER4

10x10MSA? (v2),

Future: Analog Coherent

DWDM

10 x 10G Digital Electrical I/O +

QSFP

28

QSFP

28

QSFP

28

QSFP

28 C

FP

4C

FP

4C

FP

4C

FP

4

CFP

2C

FP

2C

FP

2C

FP

2

5

Future: Digital DWDM

Coherent

10 x 10G Digital Electrical I/O

10 x 10G Digital Electrical I/O +

4 x 25G Digital Electrical I/O +

4 x 25G Analog I/O

QSFP28: 100GBASE-SR4,

100GBASE-CR4 (copper)

4 x 25G Digital Electrical I/O

All Rights Reserved, ©2014 Fujitsu Network Communications

Page 7: New Data Center and Transport Interconnect Technology

CFP / CFP2 / CFP4 Client Devices

10:4Gearbox+ Retime

4 x Driver

4 x Receiver

4 x TOSA+ WDM

WDM +4 x ROSA

Optical I/O

4 x Retime +

10 x

10G

Dig

ital

4 x

25G

Dig

ital

CFP Client~24w

Gen

1

6All Rights Reserved, ©2014 Fujitsu Network Communications

4 x Retime + Driver

4 x Receiver+ Retime

IntegratedMultidevice

TOSA+ROSA+ WDMs

Optical I/O

4 x

25G

Dig

ital

(10x10MSA version is 10 parallel channels at 10G)

CFP2 Client8~12w

4 x

25G

Ana

log

CFP4 or QSFP28 Client

4 x VCSEL4 x PIN

~4.5w

4 x Retime + Driver

4 x Receiver+ Retime

Optical I/O 100m

Gen

2F

utur

e

Page 8: New Data Center and Transport Interconnect Technology

100GBASE-SR10 vs. 100GBASE-SR4Generation 1, CFP form factor : Generation 2, QSFP28 form factor

10 x retime &VCSELdriver

10 E

lect

rical

Inte

rfac

e

10 fiber MMF

MP

O o

ptic

al c

onne

ctor

Generation 1100GBASE-SR10

10G / lane

7All Rights Reserved, ©2014 Fujitsu Network Communications

10 x PINreceive amp

& retime

CA

UI-

10 E

lect

rical

Inte

rfac

e

10 fiber MMF

MP

O o

ptic

al c

onne

ctor

CFP

4 x retime &VCSELdriver

4 x PINreceive amp

& retime

CA

UI-

4 E

lect

rical

Inte

rfac

e

4 fiber MMF

4 fiber MMFM

PO

opt

ical

con

nect

or

QSFP28

10G / lane

Generation 2100GBASE-SR4

25G / lane

Page 9: New Data Center and Transport Interconnect Technology

QSFP28 Client Device

� IEEE 802.3bm considered retimer-less interface for 20m (resulting in ~1.5w QSFP28), but rejected.� 100m MMF requires retimer.� 20m market was too small to develop independent interface

type from 100m.� Might be used in future very short reach applications.

� Proprietary Active Optical Cable interfaces adopted QSFP28 / 1.5w form factor.

8All Rights Reserved, ©2014 Fujitsu Network Communications

Optical I/O

4 x

25G

Ana

log

QSFP28 Client

4 x Driver4 x VCSEL

4 x PIN

4 x Lim Amp~1.5w

Page 10: New Data Center and Transport Interconnect Technology

Package Trends – 100GE Client Optics

� 1st generation: CFP: for MMF and SMF (actual)

� 2nd generation: CFP2, CPAK (actual)

� 3rd generation: CFP4, QSFP28 (forecast, actual)

9All Rights Reserved, ©2014 Fujitsu Network Communications

QSFP28CFP CFP2 CFP4

Page 11: New Data Center and Transport Interconnect Technology

Some 400GE Adopted ObjectivesSome Initial Ideas� Support a BER of better than or equal to 10-13 at the MAC/PLS service

interface (or the frame loss ratio equivalent)� Provide appropriate support for OTN� Specify optional Energy Efficient Ethernet (EEE) capability for 400 Gb/s

PHYs� Provide physical layer specifications which support link distances of:

� At least 100 m over MMF� At least 500 m over SMF� At least 500 m over SMF� At least 2 km over SMF� At least 10 km over SMF

� 25G x 16 VCSEL looks promising for MMF…� Small package (CDFP?), new 16-position MMF MT/MP connector.� Potential for very high density and lower cost.

� Several formats including 4λ-DMT and 8λ-PAM4 being studied for duplex SMF.

10All Rights Reserved, ©2014 Fujitsu Network Communications

Page 12: New Data Center and Transport Interconnect Technology

Form Factor Evolution 400GE Client

CD

P

CD

P2

Ref: oif2012.346.02

Gen 1: CDP Client:400GBASE-???

16 x 25G Digital Electrical I/O

Gen 2: CDP2 Client400GBASE-???

8 x 50G Digital Electrical I/O

16x25Gelectrical

lanes

8x50Gelectrical

lanes

CD

P4

4x100Gelectricallanes ??

11

XAUI = 10GEXLAUI = 40GECAUI = 100GE

CDAUI = 400GE

Far Future: CDP4 Client: 400GBASE-???

Are electrical lanes practical at 100G?

All Rights Reserved, ©2014 Fujitsu Network Communications

Note: originally called CDFP in the OIF presentation. Renamed to CDP.

Page 13: New Data Center and Transport Interconnect Technology

CDFP MSA (for 400GE) March 10, 2014 MSA Rev 1.0

� Provides 16 x 25G electrical interface.

� Optimized for 16-wide VCSEL based MMF. TIA concurrently working on standard for 2 x 16 MMF fiber ribbon and MTO/MTP MMF connector.

� Could be called 400GBASE-SR16 if IEEE standardized in 2017.� Desire by some in IEEE to have a 4 x 100GBASE-SR4 breakout mode of operation.

� Card cage is small, but cage + plug in roughly the same size as 4 x QSFP28

12All Rights Reserved, ©2014 Fujitsu Network Communications

Page 14: New Data Center and Transport Interconnect Technology

1 Terabit Ethernet

� IEEE elected to work on 400GE as opposed to 1TE due to significant technical issues.� Very small size, low power, low cost and high production volume are

key requirements for intra-datacenter optics (TOR Ethernet switch interconnect).

� Extrapolating current technology: 40 channels x 25G VCSEL. � Would require 40-wide MMF fiber ribbon x 2 (80 total fibers).� Electrical interconnect to the package would be massive.� Electrical interconnect to the package would be massive.

� Faster electrical signaling speeds and multi-level modulation may be possibilities.� Not ready for the IEEE application.

� Proposals for DMT and PAM-4 technology for 400GE.� 500m – 10km duplex SMF.� Future: Might form basis for 1TE Duplex SMF Ethernet client

interconnect.

13All Rights Reserved, ©2014 Fujitsu Network Communications

Page 15: New Data Center and Transport Interconnect Technology

Coherent DWDM PackagingNetwork Optics

� DWDM Coherent 100G optics moving towards CFP2 form factor.

� Two approaches:� Digital Interface to Optics

• Places DSP inside the optics package.• Pros: well-quantified optical performance.• Pros: well-quantified optical performance.• Cons: DSP power consumption makes thermal issues extremely

challenging.

� Analog Interface to Optics.• DSP is outside the optics package.• Pros: multivendor optical sourcing, low cost, thermal management fits

CFP2 package well. CFP4 may become practical later.• Cons: PC board layout and DSP placement may impact optical span

performance in strong or weak ways (unknown at this time).

14All Rights Reserved, ©2014 Fujitsu Network Communications

Page 16: New Data Center and Transport Interconnect Technology

CFP2 Analog DWDM Coherent Module

4 x Driver

4 x TIA PBS + Coherent QuadCombiner + 8 x PIN

DWDMCoherent

Optical I/O

LaserLocal Osc

DP-QPSKModulator + PBC

CFP2 Optical Package

DSPASIC

15All Rights Reserved, ©2014 Fujitsu Network Communications

4 x ~32G Analog

• Analog interface and copper traces between DSP and CFP2 optics will impact the span reach and optical performance.

• Skew, reflection, attenuation, crosstalk.• Quantification of the impact requires actual DSP, PC Board, and

optical CFP2 modules, and characterization.

Page 17: New Data Center and Transport Interconnect Technology

CFP2 Digital DWDM Coherent Module

4 x Driver

4 x TIA PBS + Coherent QuadCombiner + 8 x PIN

DWDMCoherent

Optical I/O

CA

UI-

4 In

terf

ace

LaserLocal Osc

DP-QPSKModulator + PBC

CFP Optical Package

DSPASIC

16All Rights Reserved, ©2014 Fujitsu Network Communications

• Standard CAUI-4 interface and copper traces between Host and Module.• Optical span performance not dependent on host.

• CFP package currently required due to high power dissipation.

Page 18: New Data Center and Transport Interconnect Technology

Analog CFP2 IssuesDigital CFP Issues� Interface to Analog CFP2 DWDM Coherent transceiver.

� DSP is external to the optics package.� Copper traces connect analog I/O from DSP to Optics.� Signaling rate is about 32 Gbps. Digitizing rate of DSP ADC is about 64

Gsps.� Future generations (class 2, 3) planned to additionally support 16QAM.

� Analog interface, DSP, copper traces, optical module all have an impact on the optical span performance.impact on the optical span performance.� Too early to tell how tightly constrained the optical performance will be.

• Performance may be weakly or strongly impacted by PCB motherboard, DSP, copper traces, and/or optics module changes.

• Might be addressable with conservative design rules.• Might be addressable by complete chain characterization (but this can get

complex). • Optics + DSP + PCB motherboard to determine performance.

� Digital module is large due to high power DSP inside optical envelope.

� Limited supply base for digital version.